• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 157
  • 13
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 177
  • 74
  • 30
  • 24
  • 23
  • 23
  • 21
  • 19
  • 18
  • 18
  • 17
  • 17
  • 16
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Acidose metabólica em pacientes cirúrgicos de alto risco: importância prognóstica / Metabolic acidosis assessment in high-risk surgical patients: prognostic importance

João Manoel da Silva Junior 26 November 2015 (has links)
Justificativa e Objetivos: Acidose é uma desordem muito frequente em pacientes cirúrgicos. Neste cenário, permanecem incertas as implicações clínicas da acidose e características de cada tipo. Portanto, é relevante tentar elucidar o papel de cada tipo de acidose no prognóstico de pacientes cirúrgicos de alto risco. Método: Trata-se de estudo multicêntrico observacional prospectivo, realizado em três diferentes hospitais. Os pacientes que necessitassem no pós-operatório de cuidados intensivos foram incluídos no estudo consecutivamente. Pacientes com baixa expectativa de vida (câncer sem perspectiva de tratamento), pacientes com insuficiência hepática (child B ou C), insuficiência renal (Clearence de creatinina < 50 mL/min ou hemodiálise prévia), diagnóstico de diabetes previamente foram excluídos. Os pacientes classificados na admissão da UTI quanto ao tipo de acidose que desenvolviam no pós-operatório imediato foram acompanhados até 30 dias e alta hospitalar. Tal classificação avaliou acidose metabólica, pela quantificação da diferença de base menor que -4 mmol/L, anion gap corrigido pela albumina (AG) e lactato aumentados, quando maiores que 12 e 2 mmo/L, respectivamente. Então, os pacientes foram classificados como acidose metabólica hiperlactatemica, aumentado e normal (hipercloremica) anion gap corrigido pela albumina. Resultados: O total de 618 pacientes foram incluídos durante dois anos. A incidência de acidose metabólica foi 59,1% na UTI, porém 148 (23,9%) apresentaram hipercloremica, 131 (21,2%) revelaram hiperlactatemia, 86 (13,9%) AG aumentado e em 253 (40,9%) não ocorreu acidose metabólica. Dentre todas as cirurgias, pacientes de cirurgia gastrointestinal foram associados a maiores porcentagens de acidose metabólica 46,2% versus 19,8% sem acidose, P < 0,05. Interessantemente, acidose com hipercloremia apresentou mais altos valores de cloro na admissão da UTI 115,0 ± 5,7 meq/L (P < 0,05) e receberam maiores quantidades de solução fisiológica 0,9% no intraoperatório 3000,0 (2000,0 - 4000,0) mL (P < 0,05). Entretanto, apesar dos pacientes não apresentarem diferenças entre escores de gravidade (SAPS 3, SOFA e ASA), idade e tempo cirúrgicos, ocorreram diferenças em relação a complicações e mortalidade no pós-operatório quando os pacientes mantinham acidose após 12 horas de pós-operatório. Pacientes com lactato e AG aumentados no pós-operatório imediato apresentaram maiores complicações, seguido dos pacientes com hipercloremia, e os sem acidose, respectivamente 68,8%; 68,6%; 65,8% e 59,3%, P = 0,03. Cardiovascular e renal disfunções foram as principais complicações e o grupo hiperlactatemia mostrou maior incidência em comparação aos outros grupos. O mesmo foi verificado em relação à mortalidade hospitalar e em 30 dias de seguimento os grupos hiperlactatemia, AG aumentado, hipercloremicos e sem acidose foram respectivamente 30,1% (HR 1,61, IC 95% 1,02 - 2,53); 24,3% (HR 1,37, IC 95% 0,76 - 2,46); 18,4% (HR 1,55, IC 95% 0,90 - 2,67) e 10,3%, Log-Rank = 0,03. Conclusão: A incidência de acidose metabólica em pacientes cirúrgicos de alto risco no pós-operatório é elevada, principalmente a do tipo hipercloremia. Pacientes cirúrgicos que desenvolvem acidose metabólica, dependendo das características, apresentam piores prognósticos em relação aos pacientes sem acidose, além disso, este estudo demonstra que diferentes etiologias de acidose metabólica estão associadas com diferentes taxas de mortalidade e morbidade no pós-operatório / Background: Acidosis is a very frequent disorder in surgical patients. In this patient set there remains uncertainty the clinic implications from acidosis and characteristics postoperatively. Therefore, it is very important to evaluate the role of each acidosis type in outcome for high-risk surgical patients. Methods: Multicenter prospective observational study was performed in three different hospitals. The patients who needed postoperative ICU were involved in the study consecutively. Patients with low life expectancy (cancer without treatment), hepatic failure, renal failure, and diabetic diagnosis were excluded. The patients were followed until 30 days and hospital discharge. On ICU admission, immediately postoperative period, the patients were classified to each type of acidosis. The classification evaluated metabolic acidosis as base excess < -4 mmol/L and high albumin-corrected anion gap (AG) and hyperlactatemia, both > 12 and > 2 mmol/L, respectively. So, the metabolic acidosis classification patients were related to hyperlactatemic, high and normal (hyperchloremic) albumin-corrected anion gap. Results: The study enrolled 618 patients during 2 years. Overall, the acidosis incidence was 59.1% on ICU admission, 148 (23.9%) hyperchloremic, 131 (21.2%) hyperlactatemia, 86 (13.9%) a high anion gap and in 253 (40.9%) there was no metabolic acidosis. The hyperchloremic group presented the highest chlorine level, 115.0 ± 5.7 meq/L (P < 0.05) and highest administration of 0.9% physiologic solution intraoperatively, 3000,0 (2000,0 - 4000,0) mL (P < 0.05). However, in spite of patients didn\'t present difference in profile demographic and score prognostic, those who remain after 12 hours with acidosis, depend on groups classification in postoperatively showed greater ICU complications, respectively, hyperlactatemia group 68.8%; high anion gap 68.6%; hyperchloremic 65.8% and no acidosis 59.3%, P = 0.03. Cardiovascular and renal dysfunctions were the main complications and hyperlactatemia group showed the highest in all of them. The same was verified in related to 30 days follow-up and hospital mortality rate respectively 30.1% (HR 1.61, IC 95% 1.02 - 2.53) hyperlactatemic; 24.3% (HR 1.55, IC 95% 0.90 - 2.67) high anion gap; 18.4% (HR 1.37, IC 95% 0.76 - 2.46) hyperchloremic and 10.3% no acidosis group, Log-Rank = 0.03. Conclusions: Metabolic acidosis in surgical patients is a very important complication postoperatively, mainly hyperchloremic. Patients who developed metabolic acidosis postoperatively depend on group classification presented worst outcomes compared to no acidosis patients; this result showed that different kinds of acidosis represented different outcomes postoperatively
162

Sistema lipossomal de ftalocianina de cloro-alumínio, contendo ácido fólico, aplicada à terapia fotodinâmica / Chloro-aluminum phthalocyanine liposomal system, containing folic acid, applied to photodynamic therapy

Camila Vizentini Silva 20 August 2013 (has links)
A Terapia Fotodinâmica (TFD) é um tratamento usado principalmente na terapia anticâncer e que depende da retenção de um composto fotossensibilizante nas células tumorais e posterior irradiação dessas células com luz visível. Após ativação, o fármaco pode gerar espécies reativas de oxigênio (EROs), como o oxigênio singlete (1O2) e radicais (O2-, OH), que são capazes de danificar membranas, DNA e outras estruturas celulares, induzindo a apoptose ou necrose das células tumorais. O ácido fólico, por ser super expressado na superfície das células de alguns tipos de cânceres (principalmente os ginecológicos), pode desempenhar o papel de vetorizador, tornando-se um importante aliado aos sistemas de liberação de fármacos. Neste trabalho foi avaliado o uso de ácido fólico como aditivo aos lipossomas contendo ftalocianina de cloro-alumínio como fármaco fotossensibilizante, aplicados em TFD com células MCF7. Os estudos demonstraram que os sistemas lipossomais desenvolvidos apresentam tamanho nanométrico (menor que 200 nm) e possuem biocompatibilidade quando avaliados em cultura celular de monocamada. Além disso, foi possível observar o efeito fototóxico satisfatório das formulações e o aumento da internalização do fármaco, quando utilizado o ácido fólico como vetorizador. / Photodynamic Therapy (PDT) is mainly used in anticancer therapy. The efficiency of this treatment is dependent on retention of photosensitizer compound at the tumor cells and posterior irradiation of these cells with visible light. After activation, the drug may generate reactive oxygen species (ROS) such as singlet oxygen (1O2) and radicals (O2-, OH), which are capable of damaging membranes, DNA and other cell structures, inducing apoptosis or necrosis of tumor cells. Folic acid is super-expressed on the surface of some cancers cells (especially gynecological cancer cells) and can play the role of target system, becoming an important ally for drug delivery systems. This study evaluated the use of folic acid as an additive to liposomes containing chloro-aluminum phthalocyanine as a photosensitizer drug, applied in PDT with MCF7 cells. These studies showed that liposomal systems have nanometer size (less than 200 nm) and have biocompatibility when evaluated in monolayer cell culture. Moreover, it was possible to observe satisfactory phototoxic effect of the formulations and increased internalization of the drug when folic acid is used.
163

Nanopartículas lipídicas sólidas e vesículas cataniônicas contendo ftalocianina de cloro alumínio aplicadas nos processos fotodinâmicos / Solid lipid nanoparticles and catanionic vesicles loaded with aluminum phthalocyanine chloride to be applied in photodynamic process

Patrícia Leme Goto 15 March 2016 (has links)
O trabalho apresentado foi realizado em duas etapas independentes e baseou-se no estudo de diferentes sistemas nanométricos para viabilizar a aplicação da ftalocianina de cloro alumínio (ClAlPc) na terapia fotodinâmica (TFD) para o tratamento do câncer de pele do tipo melanoma. O fármaco fotossensibilizante (FS) utilizado apresenta propriedades físico-químicas que lhe permitem exercer sua atividade fotodinâmica com excelência, sem a interferência do cromóforo endógeno melanina existente nas células melanocíticas. Para driblar sua elevada hidrofobicidade, ClAlPc foi encapsulada em sistemas nanométricos para administração em meio fisiológico. Inicialmente nanopartículas lipídicas sólidas (NLS) foram desenvolvidas por emulsificação direta, após um estudo de elaboração do diagrama de fases. O compritol foi o lipídio sólido escolhido para compor as NLS, com diferentes concentrações de ClAlPc. Todas as formulações desenvolvidas foram devidamente caracterizadas, com tamanho médio entre 100 e 200 nm, baixa polidispersão, potencial zeta adequadamente negativo (~|30| mV), drug loading de ClAlPc entre 76-94% (com pequena redução após 24 meses) e alta eficiência de encapsulação (E.E.). A morfologia arredondada das nanopartículas foi confirmada por microscopia eletrônica de transmissão e de força atômica. A estabilidade das NLS foi de 24 meses. A avaliação da cristalinidade do lipídio revelou a integração da ClAlPc à matriz lipídica da NLS, presença de estruturas polimórficas e grau de cristalinidade adequado, sem alterações após 24 meses. Nos estudos de difusão in vitro, observou-se que ftalocianina encapsulada nas NLS acumulam-se preferencialmente na epiderme e derme do que no estrato córneo, sem traços de permeação do ativo. Foi confirmado o caráter biocompatível das NLS sobre fibroblastos NIH-3T3. A ftalocianina encapsulada nas NLS não foi tóxica na linhagem de melanoma B16-F10 na ausência de luz, porém, apresentou excelente efeito fototóxico (0,75 ?g mL-1 de ClAlPc nanoencapsulada e irradiação entre 0,5 e 2,0 J cm-2), com redução da viabilidade celular de 87%. O segundo sistema de veiculação estudado foram as vesículas cataniônicas (VesCat), que se formam espontaneamente em água com o tensoativo TriCat 12. A obtenção das vesículas contendo ClAlPc envolve uma etapa adicional, para remoção de solvente orgânico, que foi aprimorada, reduzindo o tempo de produção em 55%. As VesCat/ClAlPc obtidas mantiveram suas propriedades físico-químicas e morfologia arredondada (confirmada por microscopia eletrônica de varredura), drug loading de 47% e alta E.E. Os resultados comprovaram que a aplicação desses dois sistemas nanométricos é altamente eficiente para aplicação da TFD no tratamento do câncer de pele do tipo melanoma ou outras doenças cutâneas, apresentando características favoráveis para avanços nos estudos de fase clínica e pré-clínica. / The present work was conducted in two independent steps, which were based on the study of different nanometric systems that make feasible the application of aluminum phthalocyanine chloride (ClAlPc) in the photodynamic therapy (PDT) to the melanoma skin cancer treatment. The photosensitizer (PS) used has physical-chemical properties that allow it to perform its photodynamic activity with excellence, without the interference of the melanin, an endogenous chromophore found in melanotic cells. In order to circumvent the high PS hydrophobicity, ClAlPc was encapsulated into nanosystems to administration in physiological environment. At first, solid lipid nanoparticles (SLN) were developed by direct emulsification process after drawing up phase diagram study. The solid lipid compritol was chosen to make the SLN, produced with different ClAlPc concentrations. The developed samples were properly characterized with mean size between 100-200 nm, low polydispersity, negative zeta potential (~|30| mV), ClAlPc drug loading around 76-94% (with slight decrease after 24 months) and high encapsulation efficiency (EE). The round shape of SLN was confirmed by transmission electron microscopy and atomic force microscopy. The nanoparticles were stable for at least 24 months. The evaluation of lipid crystallinity has proved the ClAlPc integration to SLN lipid matrix, the presence of polymorphic structures and a suitable crystalline degree, without large variations after 24 months. In the in vitro diffusion studies were observed that phthalocyanine conveyed in the nanoparticles accumulates preferably in the epidermis and dermis than in the stratum corneum, without any drug permeation traits. The NLS biocompatibility was confirmed on NIH-3T3 fibroblasts. ClAlPc-loaded NLS did not exhibit toxicity on B16-F10 melanoma cell line in the dark, but it was shown their outstanding phototoxicity effect (0.75 ?g mL-1 of encapsulated ClAlPc and irradiation between 0.5 and 2.0 J cm-2) with cell viability reduction of 87%. The second drug delivery system studied were the catanionic vesicles (VesCat) that are spontaneously obtained by mixing the self-assembly surfactant TriCat 12 in water. The production of ClAlPc-loaded vesicles comprises an additional step (to remove the organic solvent) that was optimized, saving 55% of the production time. The final VesCat/ClAlPc kept their physical-chemical properties and round shape (confirmed by scanning electron microscopy), drug loading of 47% and high EE. Hence, the results have proved the great efficiency of these two nanometric systems applied in the PDT to the treatment of melanoma skin cancer and other cutaneous disease, useful features for further progress towards preclinical and clinical trials.
164

Comparação da resistência de protozoários patogênicos - Giardia spp. e Cryptosporidium spp. - e de microrganismos indicadores à desinfecção sequencial cloro-radiação ultravioleta e ozônio-radiação ultravioleta / Comparion of the resistance of pathogenic protozoa - Giardia spp. and Cryptosporidium spp. - and indicators microorganisms to sequential disinfection with chlorine-ultraviolet radiation and ozone-ultraviolet radiation

Raphael Corrêa Medeiros 30 April 2010 (has links)
Este trabalho teve por objetivo estudar a desinfecção seqüencial cloro-radiação ultravioleta e ozônio-radiação ultravioleta a fim de avaliar a resistência de microrganismos indicadores de poluição fecal - E. coli, coliformes totais e Clostridium perfringens - e compará-la à dos protozoários patogênicos: Giardia spp. e Cryptosporidium spp.. Houve, primeiramente, monitoramento do reator anaeróbio UASB cujo efluente foi utilizado neste estudo. Foi, então, verificado o comportamento das espécies residuais de cloro no esgoto e conduzido um estudo de parâmetros indicadores (pH, potencial de oxi-redução e condutividade) para o breakpoint. Na desinfecção, foram empregados o cloro, ozônio e radiação ultravioleta; separados, e seqüencialmente. Os ensaios realizados com ozônio promoveram remoção de DQO, sólidos e dos valores de absorbância em 254 nm, diferentemente do cloro. A ordem crescente de resistência à desinfecção foi: E. coli < coliformes totais < C. perfringens < protozoários. Houve correlação em alguns ensaios entre a bactéria esporulada C. perfringens e Giardia spp.. O efeito sinérgico, promovido pela desinfecção seqüencial, foi evidenciado em alguns experimentos para C. perfringens e Giardia spp. / The present dissertation reports on the study of the sequential disinfection with chlorine-ultraviolet radiation and ozone-ultraviolet radiation to evaluate the resistance of microorganisms that indicate fecal pollution - E. coli, total coliforms and Clostridium perfringens - and compare it to the resistance of pathogenic protozoa: Giardia spp. and Cryptosporidium spp.. Firstly, the UASB reactor, whose effluent was utilized in this study, was monitored. Then the behavior of the residual species of chlorine in the sanitary sewage was verified and a study of the indicating parameters (pH, oxi-reduction potential and conductivity) for the breakpoint was conducted. Chlorine, ozone and ultraviolet radiation were used separately and sequentially in the disinfection. Tests performed with ozone promoted removal of COD, solids and absorbance values of 254 nm, differently from chlorine. The order of resistance to disinfection was: E. coli < total coliforms < Clostridium perfringens < protozoa. There was a correlation in some tests between spore-forming bacterium Clostridium perfringens and Giardia spp.. The synergic effect caused by the sequential disinfection was observed in some experiments for C. perfringens and Giardia spp.
165

Avaliação da resistência de microrganismos patogênicos à desinfecção sequencial com ozônio-radiação ultravioleta e cloro-radiação ultravioleta / Resistance evaluation of pathogenic microorganisms to sequential disinfection with ozone-ultraviolet radiation and chlorine-ultraviolet radiation

Juliana Lourenção 05 June 2009 (has links)
A remoção de microrganismos patogênicos através da desinfecção é uma necessidade para diminuir a incidência de doenças na população humana relacionadas com poluição fecal. A desinfecção sequencial tem grande potencial na remoção de microrganismos, quando comparada com a desinfecção convencional (um desinfetante). Neste trabalho buscou-se comparar a resistência de microrganismos indicadores de bactérias - E. coli e coliformes totais - e bactérias esporuladas - Clostridium perfringens quanto à desinfecção sequencial empregando cloro seguido de radiação ultravioleta e ozônio seguido de radiação ultravioleta; e à desinfecção convencional utilizando-se os mesmos desinfetantes aplicados individualmente em esgoto sanitário tratado previamente em reator UASB. Os ensaios foram realizados em batelada. As dosagens de cloro aplicadas foram de 10, 20 e 30 mg\'CL IND.2\'/L; de ozônio foram de 5,6; 11 e 16,5 mg\'O IND.3\'/L, ambos para os tempos de contato 10, 20 e 30 minutos. Na desinfecção sequencial com cloro foram aplicadas as doses de 1, 5 e 10 Wh/\'M POT.3\' de radiação UV; com ozônio, as doses de radiação foram variadas de 0,5 a 10 Wh/\'M POT.3\'. Na desinfecção sequencial de cloro-UV, foram removidos 2,5 e 5,2 log de C. perfringens e coliformes totais, respectivamente contra 1,5 e 4,2 log na desinfecção convencional para os mesmos microrganismos. Na desinfecção com cloro, a ordem decrescente de resistência foi: C. perfringens > coliformes totais > E. coli. Para ozônio seguido de UV, C. perfringens apresentou maior resistência e, em alguns ensaios, E. coli apresentou-se mais resistente que coliformes totais. A ação do ozônio mostrou-se notável para a melhoria da qualidade do esgoto tratado avaliada pela diminuição das concentrações de sólidos suspensos totais, sólidos totais, absorbância em comprimento de onda de 254 nm e da DQO, diferentemente do esgoto clorado no qual ocorreu o aumento nos valores destas variáveis físico-químicas. A ação da radiação ultravioleta foi potencializada quando aplicada sequencialmente ao cloro e ao ozônio. / The removal of pathogenic microorganisms through disinfection is a necessity to decrease the incidence of diseases in the human population related to fecal pollution. Sequential disinfection has a great potential on the removal of microorganisms when compared to conventional disinfection (single disinfectant). This work compared the resistance of indicators microorganisms of bacteria - E. coli and total coliforms - and spore-forming bacteria - Clostridium perfringens concerning the sequential and conventional disinfections. The sequential disinfection initially employed chlorine followed by ultraviolet radiation and ozone followed by ultraviolet radiation. The conventional disinfection utilized the same disinfectants individually applied in sanitary sewage previously treated in UASB reactor. The tests were made in batch. The chlorine dosages applied were 10, 20 and 30 mg\'CL IND.2\'/L; ozone were 5,6; 11 and 16,5 mg\'O IND.3\'/L, both for the contact times 10, 20 and 30 minutes. In the sequential disinfection with chlorine dosages of 1, 5 and 10 Wh/\'M POT.3\' of UV radiation were applied; with ozone, the dosages of radiation varied from 0,5 to 10 Wh/\'M POT.3\'. In the sequential disinfection with UV-chlorine were inactived 2,5 and 5,2 log of C. perfringens and total coliforms respectively, against 1,5 and 4,2 log in the conventional disinfection for the same microorganisms. In the chlorine disinfection, the decreasing resistance order was: C. perfringens > total coliforms > E. coli. In the ozone disinfection followed by UV, C. perfringens manifested more resistance and, in some assays, E. coli was more resistant than total coliforms. The action of ozone was outstanding for the improvement of treated sewage quality assessed by the decreasing of total suspended solids concentration, total solids absorbance at a wavelength of 254 nm and of DQO, differently from the chlorine sewage in which occurred an increase of the values of the physical-chemical variables. The ultraviolet radiation action was potentiated when sequentially applied to chlorine and to ozone.
166

Avaliação das correntes contínuas, pulsada e constante, pelo método de iontoforese por pilocarpina em indivíduos com e sem fibrose cística / Evaluation of direct constant and direct pulsed currents by pilocarpine iontophoresis in cystic fibrosis and healthy individuals

Souza Gomez, Carla Cristina, 1985- 26 August 2018 (has links)
Orientadores: José Dirceu Ribeiro, Francisco Ubaldo Vieira Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-26T00:51:01Z (GMT). No. of bitstreams: 1 SouzaGomez_CarlaCristina_M.pdf: 3648408 bytes, checksum: 8fc98c01df413aea0740fb6bb16723a1 (MD5) Previous issue date: 2014 / Resumo: Introdução: O teste do suor clássico (TSC) é aceito como padrão-ouro para o diagnóstico da fibrose cística (FC). Objetivo: Comparara estimulação e peso do suor produzido, os efeitos colaterais associados ao uso das correntes, contínua pulsada (CCP) e contínua constante (CCC) e determinar o tempo ideal para a estimulação e para a coleta de suor em indivíduos com e sem FC. Método: Estudo de intervenção prospectivo de corte transversal. Experimento 1(braço direito): CCC e CCP. Tempo de estimulação (TE) de 10min e o de coleta do suor de 30min. Correntes de 0,5; 0,75; 1,0; e 1,5mA e frequências de 0; 200; 1000; e 5000Hz. Experimento 2 (braço esquerdo): Corrente de 1,0mA; TE: 5 e 10min e coleta de 15 e 30min com frequências de 0; 200; 1000; e 5000Hz. Ambos os experimentos foram testados com densidade de corrente (DC) de 0,07 a 0,21mA/cm2. Experimento 3: Avaliar a CCP e a CCC como métodos diagnósticos para a FC comparando com diagnósticos estabelecidos por estudos na biópsia retal e sequenciamento do gene CFTR(do inglês, Cystic Fibrosis Transmembrane Condutance Regulator). Resultados: Participaram do estudo48 sujeitos (79,16% do sexo feminino), com média de 29,54±8,87 anos de idade. Não houve diferença estatística entre a interação da frequência e da corrente no peso do suor (p=0,75). Houve associação do peso do suor com a frequência de estímulo (p=0,0088) e corrente utilizada para a obtenção de sudorese (p=0,0025). A produção de suor foi maior no tempo de 10min de estimulação (p=0,0023). A coleta do suor foi maior no tempo de 30min (p=0,0019). A impedância da pele não foi influenciada pelo TE e de coleta do suor (p>0,05). A frequência da corrente utilizada mostrou associação inversa com a impedância da pele (p<0,0001). A temperatura da pele mensurada antes da estimulação foi maior que a temperatura após a estimulação (p=0,0001). No experimento 3 (29 indivíduos)a CCP mostrou melhor índice kappa comparada a CCC (0.92versus 0.52, respectivamente). Conclusão: A realização do TSC tanto com CCC quanto CCP utilizando DC de 0,14 a 0,21mA/cm2 mostrou eficácia nas etapas de estimulação e coleta de suor, sem efeitos colaterais. O tempo ideal para a estimulação e para a coleta de suor foi, respectivamente, 10 e 30min / Abstract: Background: The classic sweat test (CST) is still accepted as the goldstandard method for cystic fibrosis (CF) diagnosis. Objective: To compare the production and volume of sweat, the side-effects caused by direct pulsed current (DPC) and direct constant current (DCC) and to determine the stimulation time for stimulation and sweat for collection in CF and non-CF individuals. Method: Prospective study of cross-sectional intervention. Experiment 1 (right arm): DPC and DCC. Stimulation time (ST) of 10min and sweat collection every 30min. Currents of 0.5; 0.75; 1.0; and 1.5mA and frequencies of 0; 200; 1000; and 5000Hz. Experiment 2 (left arm): current of 1mA, ST: 5 and 10min and collection at 15 and 30min interval with frequencies of 0; 200; 1000; and 5000Hz. Both experiments were tested with current density (CD) ranging from 0.07 to 0.21mA/cm2. Experiment 3: To assess CF diagnosis by DPC and DCC methods by comparison with the established by rectal biopsy diagnosis studies and sequencing of the CFTR (Cystic Fribrosis Transmembrane Condutance Regulator) gene. Results: 48 subjects (79.16% female) with mean average of 29.54 ± 8.87 years old participated in this study. There was no statistical differences between the interaction of frequency and current in sweat weight (p=0.7488). An association was found between sweat weight with the frequency of stimulation (p=0.0088) and the current used for sweating (p=0.0025). The sweat production was higher for the 10min stimulation interval (p=0.0023). The best time interval for sweat collection was 30min (p=0.0019). The skin impedance was not influenced by ST and sweat collection time (p>0.05). The frequency of the current used was inversely associated with skin impedance (p<0.0001). The skin temperature measured before the stimulation was higher than after stimulation (p=0.0001). In experiment 3 (29 subjects), the DPC showed better kappa index compared to DCC (0.92 versus 0.52, respectively). Conclusion: ST performance with both DCC and DPC using a CD of 0.14 to 0.21mA/cm2 showed efficacy in both of stimulation and sweat collection steps, without side-effects. The optimal time for stimulation and sweat collection were, respectively, 10 and 30min / Mestrado / Saude da Criança e do Adolescente / Mestra em Ciências
167

Formação de biofilme e perfil de resistência antimicrobiana e a sanitizantes de isolados de Pseudomonas spp e Listeria spp. de corte de carne de frango e bubalino / Formation biofilm and antibiotic resistance profile and sanitizers isolates of Pseudomonas spp. and Listeria spp. of chicken cuts and buffalo

Demoliner, Fernanda 20 March 2015 (has links)
Submitted by Aline Batista (alinehb.ufpel@gmail.com) on 2018-05-16T14:30:50Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Fernanda_Demoliner.pdf: 883689 bytes, checksum: 17b2361f24d2dcbcf6fa64f2b8eb26cc (MD5) / Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2018-05-16T20:23:53Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Fernanda_Demoliner.pdf: 883689 bytes, checksum: 17b2361f24d2dcbcf6fa64f2b8eb26cc (MD5) / Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2018-05-16T20:24:07Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Fernanda_Demoliner.pdf: 883689 bytes, checksum: 17b2361f24d2dcbcf6fa64f2b8eb26cc (MD5) / Made available in DSpace on 2018-05-16T20:24:07Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Fernanda_Demoliner.pdf: 883689 bytes, checksum: 17b2361f24d2dcbcf6fa64f2b8eb26cc (MD5) Previous issue date: 2015-03-20 / Sem bolsa / A adesão e formação de biofilmes de micro-organismos a superfícies de equipamentos e utensílios no processamento de alimentos resulta em grave problema para a indústria, pois atua como fonte de contaminação do alimento, por serem mais resistentes a ação de sanitizantes e antimicrobianos. O objetivo deste trabalho foi avaliar a capacidade de Pseudomonas spp. e Listeria spp., provenientes de cortes de carnes de frango e de búfalo de frigoríficos e do comércio varejista da região sul do Rio Grande do Sul, de formar biofilmes em superfície de placas de poliestireno e aço inoxidável, bem como verificar a resistência destes a sanificantes e a antimicrobianos. Foram utilizados 69 isolados bacterianos provenientes de cortes de carnes de frango e de búfalo, sendo 19 de espécies de Listeria e 50 de Pseudomonas spp. Os isolados foram avaliados quanto à formação de biofilme em microplacas de poliestireno e em corpos de prova de aço inoxidável. Os isolados formadores de biofilme em aço inoxidável foram testados quanto à ação de sanitizantes: cloro orgânico e quaternário de amônio (200 ppm) e submetidos ao teste de resistência antimicrobiana. A formação biofilme em microplacas de poliestireno foi de 73,7 % para isolados de Listeria spp. e de 32 % para isolados de Pseudomonas spp. Todos os isolados de Listeria spp. e 72% dos isolados de Pseudomonas spp. formaram biofilmes em corpos de prova de aço inoxidável. O quaternário de amônio foi mais eficaz que o cloro orgânico na redução de biofilme de Listeria spp. e Pseudomonas spp. Os isolados pertencentes ao gênero Listeria apresentaram maior resistência à penicilina (94,7 %), à clindamicina (84,2 %), à oxacilina (73,7 %) e à cefepime (57,9 %), sendo que 94,7 % foram resistentes a dois ou mais antimicrobianos. Meropenem foi o antimicrobano menos efetivo para Pseudomonas spp. Também foram encontrados 84% dos isolados de Pseudomonas spp. multirresistentes a antimicrobianos. Conclui-se que os isolados provenientes de cortes de carnes de frango e de bubalino foram formadores de biofilme em poliestireno e aço inoxidável e apresentaram resistência a antimicrobianos, o que confere riscos a saúde do consumidor. / The adhesion and microorganisms biofilm formation on surfaces of equipment and utensilsin food processingresults inserious problem for the industry because it actsas a source of contamination are less resistant to sanitizers and antimicrobial action. The objective of this study was to evaluate the ability of Pseudomonas spp. and Listeria spp. present in chicken and buffalo meat, to form biofilms on the surface of polystyrene plates and stainless steel as well as verify their resistance to sanitizers and antimicrobials. Sixty nine bacterial isolates were used, 19 species of Listeria and 50 species of Pseudomonas spp. The isolates were evaluated to their biofilm formation capacity in polystyrene microplates and stainless steel. Isolated stainless steel biofilm formers were tested for sanitizing action of organic chlorine and quaternary ammonium (200 ppm) and submitted antimicrobial resistance testing. The ability to form biofilmon polystyrene microplates was 73,7 % in isolates of Listeria spp. and 32 % for Pseudomonas spp. All isolates of Listeria spp. and 72 % of Pseudomonas spp. showed the ability to form biofilm on stainless steel specimens. The sanitizing organic chlorine and quaternary ammonium were effective to reduce Listeria spp. and Pseudomonas spp. biofilm formation in stainless steel. Quaternary ammonium was more effective than organic chlorine to reduce Listeria spp. biofilm formation from buffalo meat. Isolates belonging to the Listeria generous showed greater resistance to penicillin (94.7 %), clindamycin (84.2 %), oxacillin (73.7 %) and cefepime (57.9 %), and 94.7 % were resistant to two or more antimicrobial. Meropenem was the less effective antimicroban of or Pseudomonas spp. It was also found that 84 % of isolates of Pseudomonas spp. were multirresistentes to antimicrobianos. The isolates from chicken meat cuts and buffalo were biofilm-forming polystyrene and stainless steel and were resistant to antimicrobials, which gives risk to consumer health.
168

Aplicación de métodos de electro-generación de cloro activo y H2O2 al blanqueo de tejidos de algodón

Vitero Pérez, Felipe Nicolás 14 January 2019 (has links)
Previamente al ennoblecimiento textil, los tejidos de algodón son sometidos a procesos de preparación (desencolado, descrudado y blanqueo) que consiguen la eliminación de impurezas presentes en la superficie de la fibra. El presente trabajo aborda el estudio del proceso de blanqueo de tejidos de algodón crudo y descrudado, por medio de técnicas electroquímicas. Para ello se han empleado metodologías basadas en la electro-oxidación indirecta, concretamente la electro-generación de cloro activo (o electrocloración) o de H2O2 (a veces denominados electro-peroxidación) en ausencia o presencia de catalizadores de hierro (proceso electro-Fenton). En estos métodos, el agente blanqueante se forma por electrolisis de precursores inocuos (cloruro en el caso de la electro-cloración y oxígeno disuelto en el caso del H2O2), evitando el transporte, almacenaje y manipulación de sustancias peligrosas e inestables, lo que contribuye a mejorar el control, reproducibilidad y seguridad del proceso. El objetivo principal de esta Tesis Doctoral es el estudio de la influencia de diferentes variables de electrolisis en la evolución del grado de blanco, con el fin de determinar el conjunto de condiciones operacionales más adecuado para obtener un grado de blanco aceptable, considerando además las modificaciones de la estructura y composición química superficial, de la resistencia mecánica de los tejidos y el daño químico de las fibras. Estas propiedades se han analizado mediante espectroscopia de fotoelectrones emitidos por rayos X (XPS), espectroscopia infrarroja con transformada de Fourier con accesorio de reflectancia total atenuada (FTIR-ATR), microscopio electrónico de barrido (SEM), ensayos de tracción y medida del grado de polimerización. De la morfología de los tejidos, la microscopía SEM no revela alteraciones significativas tras los tratamientos de blanqueo mediante electro-generación de cloro activo. Los ensayos de XPS revelan que la relación O/C va aumentando con la duración de la electrólisis. Esto es debido a la oxidación/eliminación de impurezas no celulósicas y fenómenos de oxidación superficial, que implican un aumento de la concentración relativa de grupos funcionales de tipo C-O y C-OH. En el tratamiento 'ex situ', el índice O/C aumenta linealmente con el tiempo de proceso. En el tratamiento 'in situ' se observa un aumento brusco de la relación O/C en las fases tempranas de electrolisis y una evolución lineal posterior similar al tratamiento 'ex situ'. El índice O/C es semejante al medido en tejido blanqueados químicos con lejía y sensiblemente inferior al alcanzado en los procesos de descrudado alcalino o blanqueo químico con peróxido. El FTIR ATR confirma que el tratamiento de electro-cloración implica la eliminación de constituyentes de ceras y grasas de la superficie de las fibras de algodón, material protéico y posiblemente parte de sustancias pécticas y hemicelulosas. El cociente entre la intensidad de la banda de OH asociada al sistema de puente de hidrógeno y la intensidad de la banda de tensión C-H experimenta un aumento similar a la relación O/C determinada por XPS. No se ha logrado identificar ningún pico de fotoemisión o banda vibracional que sirva como diagnóstico del contenido de materia coloreada, ni se ha logrado establecer una correlación clara entre el aumento del grado de blanco del tejido y el cambio de los parámetros cuantitativos relativos a la composición superficial de los tejidos de algodón. / Previ al ennobliment tèxtil, els teixits de cotó són sotmesos a processos de preparació (desencolat, descruat i blanqueig) que aconsegueixen l'eliminació de les impureses presents a la superfície de la fibra. Aquest treball aborda l'estudi del procés de blanqueig de teixits de cotó cru y descruat, mitjançant tècniques electroquímiques. Per a açò s'han emprat metodologies basades en la electro-oxidació indirecta, concretament la electro-generació de clor actiu (O electrocloració) o de H2O2 (de vegades anomenada electro-peroxidació) en absència o presència de catalitzadors de ferro (procés electro-Fenton). En aquests mètodes, l'agent blanquejant es forma per l'electròlisi de precursors innocus (clorur en el cas de l'electro-cloració i oxigen dissolt en el cas del H2O2), evitant el transport, emmagatzematge i manipulació de substàncies perilloses i inestables, el que contribueix a millorar el control, reproduïbilitat i seguretat del procés. L'objectiu principal d'aquesta Tesi Doctoral és l'estudi de la influència de diferents variables d'electròlisi en l'evolució del grau de blanc, amb el fi de determinar el conjunt de condicions operacionals més adequat per a obtenir un grau de blanc acceptable, considerant-se amés les modificacions de l'estructura i composició química superficial, de la resistència mecànica dels teixits, i del dany químic de les fibres. Aquestes propietats s'han analitzat mitjançant espectroscòpia de fotoelectrons emesos per rajos X (XPS), espectroscòpia infraroja b transformada de Fourier amb accessori de reflectància total atenuada (FTIR-ATR), microscopi electrònic d'escombrat (SEM), assajos de tracció i mesura del grau de polimerització. De la morfologia dels teixits, la microscòpia SEM no revela alteracions significatives després dels tractaments de blanqueig mitjançant electró-generació de clor actiu. Els assajos de XPS revelen que la relació O/C va augmentant amb la durada de l'electròlisi. Aquest fet es deu a la oxidació/eliminació de impureses no cel·lulòsiques i fenòmens d'oxidació superficial, que impliquen un augment de la concentració relativa de grups funcionals del tipus C-O i C-OH. Al tractament 'ex situ', 'l'índex O/C augmenta linealment amb el temps de procés. Al tractament 'in situ' s'observa un augment brusc de la relació O/C a les fases primerenques de l'electròlisi i una evolució lineal posterior similar al tractament 'ex situ'. L'índex O/C es semblant al mesurat a teixits blanquejats químicament amb lleixiu i sensiblement inferior a l'assolit als processos de descruat alcalí o blanqueig químic amb peròxid. El FTIR ATR confirma que el tractament d'electro-cloració implica l'eliminació de constituents de ceres i greixos de la superfície de les fibres de cotó, material proteic i possiblement part de substàncies pèctiques i hemicel·luloses. El quocient entre la intensitat de la banda OH associada al sistema pont d'hidrogen i la intensitat de la banda de tensió C-H experimenta un augment similar a la relació O/C determinada per XPS. No s'ha aconseguit identificar cap pic de fotoemissió o banda vibracional que serveixi com a diagnòstic del contingut de matèria acolorida, ni s'ha aconseguit establir una correlació clara entre l'augment del grau de blanc del teixit i el canvi dels paràmetres quantitatius relatius a la composició superficial dels teixits de cotó. / Prior to the textile finishing, cotton fabrics are subjected to preparation processes (desizing, scouring and bleaching) in order to remove noncellulosic impurities present on the fiber surface. The present work deals with the study of the bleaching process of raw and scoured cotton fabrics by means of electrochemical techniques. To this end, methodologies based on indirect electro-oxidation have been used, namely the electro-generation of active chlorine (or electro-chlorination) or H2O2 (sometimes called electro-peroxidation) in the absence or presence of iron catalysts (electro-Fenton process). In these methods, the bleaching agent is formed by electrolysis of harmless precursors (chloride in the case of electro-chlorination and dissolved oxygen in the case of H2O2), thus avoiding the transport, storage and handling of hazardous and unstable substances, which contributes to improve the control, reproducibility and safety of the process. The main objective of this Doctoral Thesis is the study of the influence of different electrolysis variables on the evolution of the whiteness index, in order to determine the most suitable set of operational conditions to obtain an acceptable whiteness index, considering also the modifications of the structure and chemical composition of the surface, of the mechanical resistance of the cotton fabrics and the chemical damage of the fibers. These properties have been analyzed by X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy with attenuated total reflectance accessory (ATR-FTIR), scanning electron microscope (SEM), tensile tests and degree of polymerization. As to the morphology of the textile cotton fabric, SEM microscopy reveals no significant modifiations after the bleaching treatments by electro-generation of active chlorine. The XPS tests reveal that the O/C ratio increases with the duration of electrolysis. This is attributed to the oxidation/elimination of non-cellulosic impurities and superficial oxidation phenomena, which involve an increase in the relative concentration C-O and C-OH functional groups. In the 'ex situ' treatment, the O/C index increases linearly with the process time. In the 'in situ' treatment an abrupt increase in the O/C ratio in the early stages of electrolysis and a subsequent linear evolution similar to the 'ex situ' treatment are observed. The O/C index is similar to that measured in cotton fabrics treated with bleach, but it is significantly lower than those achieved in alkaline scouring or peroxide chemical bleaching processes. The ATR-FTIR confirms that the electro-chlorination treatment involves the elimination of constituents of waxes and fats from the surface of cotton fibers, together with proteins and possibly part of pectic and hemicellulosic substances. The ratio of the OH stretching intensity associated with the cellulose hydrogen-bonding system to the C-H stretching intensity undergoes an increase similar to the O/C ratio as determined by XPS. We could not find any any photoemission peak or vibrational band as a diagnostic signal of the content of colored matter; nor has it been possible to establish a clear correlation between the increase in the whiteness index of the bleached cotton fabrics and the change in the quantitative parameters relative to their surface composition. / Vitero Pérez, FN. (2018). Aplicación de métodos de electro-generación de cloro activo y H2O2 al blanqueo de tejidos de algodón [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/115486 / TESIS
169

Asociación entre niveles de cloro residual en el agua del hogar y presencia de síntomas respiratorios y diarrea en niños menores de 5 años: Sub-análisis de la ENDES 2015- 2019 / Association of residual chlorine levels in household water with respiratory symptoms and diarrhea in children under 5 years old: A secondary analysis of Peru Demographic and Family Health Survey, ENDES, 2015-2019

Cassaretto Mispireta, Pierina Nicole, Hualpa Mejia, Lourdes Geraldine 31 January 2022 (has links)
Introducción: La cloración de agua es usada para controlar enfermedades entéricas; sin embargo, también conlleva la formación de productos derivados que pueden dañar el epitelio respiratorio. Nuestro objetivo es evaluar si existe asociación entre el nivel de cloro residual del agua del hogar y la presencia de síntomas respiratorios y diarrea en niños menores de 5 años en el Perú. Métodos: Estudio transversal analítico basado en un análisis secundario de las cinco últimas Encuestas Demográficas y de Salud Familiar (ENDES), Perú 2015-2019. Se incluyeron menores de 5 años en cuyos hogares se realizó medición de cloro residual del agua para consumo humano. Se analizaron tres desenlaces: síntomas respiratorios sin fiebre, síntomas respiratorios con fiebre, y diarrea en los 14 días previos a la encuesta. Se obtuvieron razones de prevalencia crudas y ajustadas (RPa) empleando regresión de Poisson considerando la muestra compleja. Resultados: Se incluyeron 95631 niños, 51.2% de sexo masculino. La prevalencia de síntomas respiratorios sin fiebre fue 19.4%, de síntomas respiratorios con fiebre 14.7%, y de diarrea 11.6%. El 30.5% de hogares tuvieron niveles de cloro residual ≥0.5 mg/L, y fue no detectable en 54.6%. Niveles ≥0.5 mg/L aumentaron la probabilidad de síntomas respiratorios sin fiebre (RPa 1.09; IC95% 1.03–1.15) y redujeron presencia de diarrea (RPa 0.90; IC95% 0.84–0.96). Niveles 0.1-0.5mg/L aumentaron la probabilidad de síntomas respiratorios sin fiebre (RPa 1.10; IC95% 1.04–1.16), y redujeron diarrea (RPa 0.89; IC95% 0.83–0.96). No hubo asociación con síntomas respiratorios con fiebre. Conclusiones: Los niveles de cloro residual ≥0.5 mg/l y entre 0.1-0.5 mg/l se asociaron a mayor prevalencia de síntomas respiratorios sin fiebre, y menor prevalencia de diarrea, pero no con síntomas respiratorios con fiebre. Debería explorarse más la relación entre cloración de agua del hogar e irritación de las vías áreas en niños. / Introduction: Water chlorination is a cornerstone for enteric diseases control; however, it could also lead to disinfection-by-products formation, which may damage the respiratory epithelium. This study aims to assess association of residual chlorine levels in household water with respiratory symptoms and diarrhea in Peruvian children under 5 years old.  Methods: Cross-sectional study using data from the Demographic and Family Health Survey (ENDES) from 2015 to 2019. Subjects were children under 5 years old who had their household water tested for residual chlorine levels. Association with respiratory symptoms without fever, respiratory symptoms with fever, and diarrhea were assessed using crude and adjusted prevalence ratios (aPR) employing Poisson regression adjusted per complex sampling. Results: 95631 children were included, 51.2% males. Prevalence of respiratory symptoms without fever was 19.4%, respiratory symptoms with fever 14.7%, and diarrhea 11.6%. Households with residual chlorine levels ≥0.5 mg/L were 30.5%; and 54.6% had non-detectable levels. Levels ≥0.5 mg/L were associated with higher prevalence of respiratory symptoms without fever (aPR 1.09; 95%CI 1.03–1.15) and less diarrhea (aPR 0.90; 95%CI 0.84–0.96). Levels 0.1-0.5mg/L were associated with higher prevalence of respiratory symptoms without fever (aPR 1.10; 95%CI 1.04–1.16) and less diarrhea (aPR 0.89; 95%IC95 0.83–0.96). There was no association with respiratory symptoms with fever. Conclusions: Residual chlorine levels ≥0.5 mg/L and between 0.1-0.5 mg/L were associated with higher prevalence of respiratory symptoms without fever, and with less prevalence of diarrhea, but not with respiratory symptoms accompanied by fever. Relationship between household water chlorination and airway irritation in children should be further explored. / Tesis
170

Remoção de fitoplancton e microcistina de águas de abastecimento, pela associação das técnicas de flotação por ar dissolvido e oxidação química com cloro e permanganato de potássio / Removal of phytoplankton and microcystin from source water, by assotiation of dissolved air flotation and chemical oxidation with potassium permanganate and chlorine

Perez, Maurício Fernandes 16 May 2008 (has links)
O presente trabalho de pesquisa teve como objetivo principal avaliar a remoção de fitoplancton e microcistina em cinco fluxogramas de tratamento de água para abastecimento, que tiveram como seqüência básica as etapas de coagulação, floculação, flotação por ar dissolvido e filtração, complementados com oxidação química em diferentes pontos da seqüência básica de tratamento estabelecida. Os ensaios foram realizados em escala de laboratório, utilizando água de estudo preparada mediante a mistura de água coletada no reservatório de Barra Bonita, no Estado de São Paulo, e cultura com elevada concentração de microcistina preparada em laboratório. A concentração de microcistina na água de estudo foi mantida no intervalo de 14 a 17 µg/L. O cloreto férrico foi utilizado como agente coagulante, o permanganato de potássio e o cloro, na forma de hipoclorito de sódio, foram utilizados como agentes oxidantes. Foi observada eficiência de remoção de fitoplancton de cerca de 99,9% devido às etapas de coagulação, floculação e flotação por ar dissolvido e, conseqüentemente, remoção de microcistina contida no interior das células íntegras. A oxidação com cloro realizada após a filtração, bem como a oxidação com a associação do permanganato de potássio e cloro realizada após a flotação, resultaram em eficiência de remoção de microcistina extracelular (microcistina livre no meio líquido) da ordem de 95%, atendendo ao padrão de potabilidade com cocentrações de microcistina menores que 1,0 µg/L. A oxidação da água bruta com permanganato de potássio associada à oxidação da água flotada com cloro, apresentou o melhor desempenho de remoção de microcistina extracelular, com eficiência superior a 98%. Em todos os ensaios de oxidação química foi constatada a influência da variação do pH na remoção de microcistina, sendo que o aumento de eficiência foi associado à diminuição dos valores de pH. Foram observados indícios de remoção de trihalometanos pela flotação por ar dissolvido e redução da formação de trihalometanos quando a oxidação química foi feita com a associação do permanganato de potássio e cloro. / The aim of this research was to study the phytoplankton and microcystin removal at different treatment conditions, all based in coagulation, flocculation, dissolved air flotation and filtration, complemented by chemical oxidation applied at different points of the basic treatment sequency. The lab scale experiments was conduted with raw water prepared by a mixture of natural water, collected in Barra Bonita reservoir at São Paulo State, Brazil, and a high concentrated Microcystis culture prepared in laboratory. The microcystin concentration in raw water was kept in a range of 14 to 17 µg/L. Ferric chloride was used as coagulant, and, potassium permanganate and chlorine (sodium hypochlorite) were used as oxidants. The results showed phytoplankton removal efficiency about 99,9% by the sequency of coagulation, flocculation and dissolved air flotation, resulting a great removal of microcystin retained into the whole cells. The chlorine oxidation after filtration, as well as the oxidation with potassium permanganate and chlorine after dissolved air flotation, resulted in a microcystin removal of about 95% and concentrations under the World Health Organization drinking water guideline value of 1,0 µg/L. The raw water potassium permanganate oxidation associated with the chlorine oxidation after flotation, leaded to the best results concerning microcystin removal, with efficiency above 98%. All experimental conditions with chemical oxidation showed a relevant effect of the pH on the microcystin removal, the decrease of pH values contributed to the increase of microcystin removal. It was observed signs of THM´s removal by the dissolved air flotation and reduction of THM´s production when the chemical oxidation took place with the association of potassium permanganate and chlorine.

Page generated in 0.05 seconds