Sapa Heat Transfers koldioxidspår : En kartläggning av verksamhetens koldioxidutsläpp

Fagerberg, Maria January 2010 (has links)
Sapa Heat Transfer is a company that produces aluminum heat-exchanger strips for the automotive industry. Sapa Heat Transfer wish to chart their emissions of carbon dioxide in order to meet future demands on carbon dioxide reporting. They also would like to examine the meaning of the term “green electricity” which is marketed as carbon dioxide free, and the sort of electricity that they purchase. This report includes both direct (liquefied petroleum gas and diesel) and indirect (water, process-water, long distance heating, waste) emissions from their company. The conclusion of this report is that liquefied petroleum is the biggest contributor to the emissions of carbon dioxide and that the amount of carbon dioxide emitted from the processes is almost twice the amount of aluminum product, or 1,77 to be precise. The green electricity emits small amounts of carbon dioxide per kWh produced when analyzed in a lifecycle perspective which is also presented in this report.
162

Utvärdering av kulvertförluster : En fallstudie utförd på AB Ronnebyhus / Evaluation of culvert losses : A case study performed at AB Ronnebyhus

Waldén, Erik, Nyberg, Dennis January 2013 (has links)
Dagens samhälle står inför flera utmaningar. Befolkningen ökar i antal och förbättrade levnadsstandarder leder till att energianvändningen ökar. Av den totala energianvändningen i Sverige står byggsektorn för ca 40 %.År 1999 satte regeringen upp framtida mål för energianvändningen i Sverige. För bostäder och lokaler ska den minska med 20 % till år 2020 och med 50 % till år 2050 med referensåret 1995.AB Ronnebyhus ville få en bättre översikt över sin värmeanvändning och hur mycket som gick till förlust. Därför installerades värmemängdsmätare vid olika mätpunkter som sparar data kontinuerligt och en betydande värmeförlust upptäcktes.Syftet med studien var att leverera ett underlag för hur stora temperatur- och värmeförluster som uppkommer i de utvändigt markförlagda kulvertledningarna mellan byggnaderna i området Tallen i Ronneby.Grundtanken med undersökningen var att värmeförlusterna uppstod på grund av bristfälliga kulvertledningar då misstanke förelåg att de var omoderna. I ett tidigt skede uppdagades det att ledningarna var från år 2006 och därmed betydligt nyare än förväntat. Detta innebar att de befintliga kulvertledningarna håller en bra standard och en inriktning med andra faktorer var tvungen att beaktas. Istället låg fokus på att kontrollera flödesjusteringen av värmesystemet och undersöka framlednings- returledningstemperaturer.Med hjälp av injusteringsprotokoll, beräkningar och mätningar upptäcktes det att systemet inte är optimalt injusterat och värmeförlusterna som detta medför är betydande. För att åtgärda detta rekommenderar vi att en injustering av värmesystemet utförs så att utrustningen ska användas så optimalt som möjligt. / Today’s society is facing several challenges. The population is increasing and an improved living standards leads to increased energy consumption. Of the total energy consumption in Sweden, construction consumes about 40 %.In 1999 the Government set future goals for energy consumption in Sweden. It shall be reduced with 20 % by 2020 and with 50 % by 2050 for residential and commercial building with the reference year 1995.AB Ronnebyhus wanted to get a better overview of their use of heat and how much they lost. Therefore heat meters were installed at various point of measurement, recording data continuously. A significant heat loss was discovered.The purpose of the study is to provide a basis for how much temperature and heat losses occurs in the buried culvert pipes between the buildings in the residential area Tallen.The basic idea of the study was that the heat losses occurred due to inadequate culvert pipes because we believed they were outdated. In early stages we found out that the pipes were from 2006 and considerably newer than expected. This means that the existing culvert pipes have good standards and other factors had to be considered. Instead, focus was on the flow adjustment of the heating system and to examine the temperature of the incoming and outgoing water.Using flow adjustment protocols, calculations and measurements we discovered the heat system is not optimally adjusted and the heat losses from the system is significant.
163

Energieffektivare torkning i diskmaskiner genom ny torkmetod : Utvärdering genom praktiska försök och simuleringar / More energy efficient dishwashers through new drying method : Evaluation through practical experiments and simulations

Östberg, Daniel January 2013 (has links)
Världens energiförbrukning ökar ständigt. Detta ger upphov till stora miljöproblem där klimatförändringen är ett av de största problemen. Hushållens energiförbrukning står idag för en betydande del av den totala energianvändningen. Det är därför viktigt att effektivisera hushållens energianvändning för att reducera deras påverkan på miljön. Vitvaror, som står för en stor del av hushållens energianvändning, har en stor potential att energieffektiviseras. Ett exempel på en vitvara där mycket energi kan sparas är diskmaskiner. Diskmaskiner tvättar, sköljer och torkar smutsig disk. Med dagens diskmaskiner går det åt mindre energi och vatten än vad det gjorde förr, då detta arbete gjordes för hand. Det finns dock fler åtgärder som kan utföras för att minska diskmaskinernas energiförbrukning. Det läggs bl.a. ned mycket arbete på att minska energiförbrukningen vid uppvärmningen av vattnet i diskmaskinerna och för att minska den energi som går åt i torkfasen. En diskmaskin där uppvärmningen sker via en värmepump utvecklas av Asko Appliances AB. Värmen som behövs i diskmaskinen tar värmepumpen från en vattenbehållare, vilket får vattnet att frysa till is. Torkningen av disken i denna diskmaskin kommer att ske genom att den fuktiga luften inuti diskmaskinen förs ut med hjälp av en fläkt. Den drivs sedan, genom en luftspalt, förbi islagret där fukten i luften kondenseras mot den kalla yta som skapas av islagret. Luften förs sedan tillbaka till diskmaskinen. I detta examensarbete utvärderas denna torkmetod. Den jämförs även med den teknik som används av Asko Appliances AB idag, där den fuktiga luften förs ut ur diskmaskinen till det rum där diskmaskinen står samtidigt som rumsluft förs in. Försök kommer att utföras på en diskmaskin med ett externt islager. Utvärderingen av torkningen i försöken gjordes med hjälp av torksyning. En matematisk modell med en energibalans över torkfasen har också byggts. Simuleringar utfördes på modellen och resultaten verifierades med försöken. Från modellen beräknades mängden vatten som torkas inuti diskmaskinen under torkfasen. Resultaten från torksyningen visade att torkmetoden med islager fungerar bättre än torkmetoden som används av Asko Appliances AB idag. Höga temperaturer och luftflöden visade sig ge det bästa torkresultatet enligt både försöken och modellen. Enligt modellen är torkningen mest energieffektiv då starttemperaturen är 70 °C, men eftersom så mycket vatten som sitter på diskmaskinens väggar då torkas är den starttemperaturen inte den mest effektiva i verkligheten. Den starttemperatur som är mest energieffektiv är 60 °C. Då torkas disken lika bra och det används 0,5 MJ mindre energi än då starttemperaturen är 70 °C. / The energy consumption is constantly increasing. The results are major environmental issues in which climate change is one of the biggest problems. Household energy consumption currently account for a significant share of the total energy consumption. Therefore it is important to improve household energy consumption to reduce household environmental impact. Appliances, which accounts for a large portion of household energy use, have a great potential for energy improvement. One example of an appliance where much energy can be saved is dishwashers. Dishwashers wash, rinse and dry dirty dishes. The dishwashers produced today uses less energy and water than before, when this work was done by hand. There are still more actions that can be taken to reduce the dishwasher's energy consumption. A lot of efforts are made among other things to reduce the energy consumption during the heating of the water inside the dishwasher and to reduce the energy consumed during the drying phase. A dishwasher where the heating occurs by a heat pump is developed by Asko Appliances AB. The heat pump takes the heat that is needed for the dishwasher from a water tank, causing the water to freeze. The drying of the dishes in this dishwasher will be done by letting the humid air inside the dishwasher out, using a fan. The air is then driven past the ice stock by making it go through an air gap, where the moisture condenses from the air on the cold surface created by the ice. The air then returns back into the dishwasher. In this thesis, this drying method is evaluated and compared with the technology used by Asko Appliances AB today, where the humid air is leaving the dishwasher and is brought into the room where dishwasher stands while air from the room is entering. Experiments will be performed on a dishwasher with an external ice stock. The evaluation of the drying process experiment was done using inspection. A mathematical model with an energy balance over the drying phase was built. Simulations were performed on the model and the results were verified by the experiments. With the model, the amount of water that evaporates inside the dishwasher during the drying phase was calculated. Results from the inspection showed that the drying method using the ice stock better performs than the drying method used by Asko Appliances AB today. High temperatures and air flow rates were found to provide a better result according to the experiments and the model. The drying is according to the model most energy efficient when the starting temperature is 70 °C, but since so much water located on the dishwasher walls is dried at that starting temperature, the in reality most efficient starting temperature is 60 °C. Then the dish is dried just as well and the energy consumption is 0.5 MJ less than when the starting temperature is 70 °C.
164

Energianalys på Volvo Aero

Månsson, Markus, Wahlgren, Peter January 2008 (has links)
Detta examensarbete har genomförts på Volvo Aero i Trollhättan och består av tre delar: en kartläggning av processventilationens uppbyggnad på ett antal utvalda maskiner och beräkning av dess energiåtgång, en jämförelse ur energieffektivitetssynpunkt mellan ett nyutvecklat maskinkoncept som kallas MultiTask-Cell och traditionell tillverkning, sist har en tomgångsanalys gjorts i verkstaden för att identifiera vad som använder elenergi då ingen produktion sker. För att kunna genomföra uppgifterna har mätningar av elanvändningen gjorts på både maskinnivå och transformatorer, detta för att kunna beräkna energianvändning på utvalda maskiner och även få en helhetssyn över verkstadens energianvändning. Det har även gjorts datainsamling och intervjuer för att få grepp över processventilationens funktion och uppbyggnad. Det finns två varianter på processluften, ett där konstant relativt högt luftflöde används och ett när man genom varvtalsreglering av fläkten använder ett lägre grundflöde som forceras en viss tid vid spindelstopp. Ur energisynpunkt är metoden med grundflöde och forcering att föredra då det leder till både mindre energiförluster genom processluften och en stor minskning av fläktens elbehov. Det har även räknats ut en teoretisk energibesparing vid införande av värmeåtervinning för två maskingrupperingar. Jämförelsen mellan MultiTask-cellen och traditionella maskiner har gjorts genom att mäta den energi det krävs för att tillverka en detalj för respektive tillverkningssätt. MultiTask-cellen visade sig använda cirka 25 % mindre energi än de traditionella maskinerna för tillverkning av samma typ av detalj. Tomgångsanalysen visar på ett högt effektuttag även då det ej sker någon produktion på Volvo Aero. Detta beror till stor del på att maskinerna har en relativt hög tomgångsförbrukning. Denna krävs för att hålla maskinen varm vilket ger en så problemfri uppstart som möjligt. Att byta ut allmänbelysningens armatur till nyare och modernare skulle årligen ge en betydande energibesparing.
165

Energieffektivisering i flerbostadshus : Undersökning av lönsamheten med energieffektivare ventilation

Jonsson, Reine January 2009 (has links)
This thesis is based on a case study for the real estate manager Mimer in Västerås. Mimer provides a great deal of this city’s rental apartments. Many of their buildings have ventilation systems with a type of heat-recovery called “heatpipe”. This case study focuses on two buildings which have certain problems with these heatpipes. The recovery rates of the existing systems are low, and one building suffers from a warm indoor climate in the summertime. Problems with the indoor climate seem to stem from a faulty installation of the heatpipe. This building does also have considerably higher energy consumption than the other one, which leads suspicions to overloaded fan motors.   The main purpose of this study is to retrieve information about the present situation energy- and ecomonywise. A new type of heat recovery and new fans has been chosen by Mimer in order to calculate expected new energy consumption for these buildings. These values will lead to a few LCC calculations which show life cycle costs for the existing systems and the new systems. Based on the LCC calculations one or more options will be chosen as a recommended action for the ventilation systems. The recommendations will be analysed and discussed from different point of views that are relevant for a real estate manager.
166

Energibesparande lösningar för köpcentrum och andra handelslokaler : En jämförelse mellan Sverige och Michigan / Solutions for energy efficient shopping malls and other retail buildings : A comparison between Sweden and Michigan

Snygg, Johanna January 2010 (has links)
Energieffektivisering har blivit en allt mer diskuterad fråga på sista tiden. Fokus har varit stort på både bostäder och kontor. I den här rapporten granskas handelslokaler, särskilt köpcentrum, i Sverige och i Michigan, för att finna likheter och skillnader i förutsättningar för energieffektivisering och i vilka lösningar för effektivisering som väljs. Handelslokaler i Michigan använder 30 % mer energi än svenska handelslokaler och skillnaden ligger till största del i uppvärmningsenergi. På det området har Sverige arbetat mycket med effektivisering de senaste årtiondena. En åtgärd som slagit igenom stort är att ta vara på värmen eller kylan i ventilationens frånluft genom att överföra värmen eller kylan till tilluften och därmed återföra den till lokalen, så kallat FTX-system. I Sverige har 96 % av handelslokalerna ett sådant system men i Michigan är det relativt ovanligt. En tendens som framkommer i rapporten är att fastighetsägare i Michigan, i större utsträckning än motsvarande i Sverige, satsar på olika mindre lösningar, som till exempel vita, reflekterande tak. Taken reflekterar bort solinstrålning och minskar på så sätt kylbehovet men används inte ofta i Sverige. Det trots att de, enligt Lars Pellmark på fastighetsföretaget Diligentia, skulle kunna fungera väl, framförallt på byggnader med höga interna värmelaster, som köpcentrum. Köpcentrum i Sverige använder dessutom dubbelt så mycket energi till kyla som köpcenter i Michigan använder. I handelslokaler i både Michigan och Sverige har man arbetat med att byta ut belysningsarmaturer mot effektivare modeller. Belysning är den klart största posten för elanvändning och den står för en fjärdedel respektive en tredjedel av energianvändningen i köpcentrum i Michigan respektive Sverige, så där finns mycket kvar att göra. Fortfarande används i stor utsträckning äldre lysrörsarmaturer med konventionella drivdon, som skulle kunna bytas till effektivare modeller, i både Michigan och Sverige. De stora skillnaderna i vilka energieffektiviserande lösningar som får framgångar i Michigan respektive Sverige är förvånande, trots att byggtraditionerna också skiljer sig markant åt. Utvecklingen av energieffektiviserande åtgärder tycks i mångt och mycket hållas på ett nationellt plan. Regelverk och utbud av ekonomiska incitament skiljer sig väsentligt åt mellan Michigan och Sverige och statistiken över energianvändning presenteras dessutom på olika sätt. De här faktorerna gör jämförelser av förutsättningar komplicerade. Dock har användandet av miljömärkningssystem blivit alltmer populärt, vilket också gjort att inspiration delats mellan staterna. Med internationella plattformar ökar intresset och möjligheterna att lära av varandra, om såväl konstruktions- och installationsmässiga åtgärder som ekonomiska incitament och andra styrmedel. / Energy efficiency has grown to be an often discussed matter today. There has been a large focus concerning both residential and office buildings. In this report retail buildings, especially malls, has been studied, in Sweden and in Michigan, to find similarities and differences in the conditions for energy efficiency and which solutions that are being chosen when energy efficiency are desired. Retail buildings in Michigan are using 30 % more energy than retail buildings in Sweden do, mostly due to high energy use for heating. Sweden has been working a lot with energy efficiency in that particular field in the last decades. One solution that has become common is heat recovery between the exhaust air and the supply air, so called HRV. In Sweden 96 % of the retail buildings have heat recovery ventilation but in Michigan it is quite rare. One trend that appears in this report is that the retail buildings I Michigan, to a larger extent than the ones in Sweden, are equipped with different smaller solutions, for example cool roofs. The white roofs reflect a majority of the sunbeams, and thereby also much of the heat, which reduces the need for cooling, but they are rarely used in Sweden. This, even though they could work well, according to Lars Pellmark from the real property company Diligentia, especially for malls since they have a high internal heat load. Malls in Sweden also use twice the energy for cooling the malls in Michigan use. Some progress has been made, both in Michigan and in Sweden, with changing the lighting fixtures in retail buildings to more energy efficient models. Lighting is unquestioned the largest part of the electricity use in retail buildings, a fourth of the total energy use in malls in Michigan, in Sweden the share is a third. There is still a lot to do in that area. In Michigan as well as Sweden, older more inefficient fluorescent lamps are still often used and the opportunities are many for exchanging them to newer, more energy efficient models. The large differences in which solutions that are chosen for energy efficient malls and retail buildings in Michigan and in Sweden are surprising, even though the building traditions are quite different. The development of energy efficiency solutions seems often being held in a national restriction. Regulations and supply of economic incentives are very diverse, in the comparison between Michigan and Sweden, and the statistics over energy use are presented in different ways, which makes them complicated to compare. The increasing popularity of green building certification systems is one thing working against the national trend. Through the certification system ideas and inspiration is shared and spread between countries. With international platforms the interest in, and possibilities for, learning from each other increases, construction- and installation wise as well as for economic incentives and other management control measures.
167

Energieffektivisering i ett reningsverk för skogsindustriellt avloppsvatten genom förfällning av extraktivämnen

Rixen, Alexandra January 2011 (has links)
Pulp- and papermills expend vast amounts of water in order to produce pulp, paper and cardboard. Hence, they alsocreate vast amounts of waste water which has to be cleaned before it can be released into the receiving body of water. Insuch a wastewater treatment plant, tremendous amounts of energy are expended by the aeration in the biologicalcleaning process. This aeration is necessary to supply the microorganisms that shall decompose organic material withoxygen, which they need for their metabolism. The transfer of oxygen from the gas phase to the liquid phase isprimarily inhibited by surface-active substances in the waste water like resin acids or fatty acids. The purpose of thisthesis has been to determine if the surface-active substances can be removed by means of chemical pre-precipitationbefore the waste water enters the biological cleaning step. Thus, the efficiency of the aeration shall be improved.In the laboratory, aeration tests were performed for plain water, water with added surface-active substances and CTMPwastewaterfrom Stora Enso Skoghalls Bruk. The test for water with added surface-active substances showed clearlythat these substances have a big influence on the aeration efficiency, which was impaired considerably compared withplain water.In order to determine how chemical precipitation influences the content of surface-active substances, screening trialswere performed with the CTMP waste water. The concentration of surface-active substances was estimated bymeasuring the surface tension of the waste water. The surface tension sinks with increasing concentration of thesesubstances. 250 ml CTMP-wastewater was precipitated with three different chemicals: PAX-XL60, PGA and AVR. Inorder to determine the optimal dosing as well as the optimal pH-value for goal-oriented precipitation of the surfaceactivesubstances, the precipitation was performed with different pH-values between 4 and 8 as well as for differentdoses of the precipitation chemicals. It was discovered that the optimal pH-value for precipitation with PAX-XL60 is7,5 while the precipitation with PGA had the optimal pH-value of 6. The optimal dosage for PAX-XL60 was 10 g/cm3,while the optimal dosage for PGA could not be determined because of the small waste water volume used in thescreening trials. The screening trials showed that the surface tension increased after precipitation with both PAX-XL60and PGA which leads to the assessment that the concentration of surface-active substances has decreased.Precipiation- and aeration trials in big lab-scale were performed at pH 7,5 and the optimal dosage of PAX-XL60. ForPGA, the precipitation and aeration trials were performed at pH 6 and the lowest dosage of the screening trials. Theaeration trials showed that precipitated CTMP-wastewater could be aerated more energy efficient than the samewastewater without precipitation.Calculations showed that energy costs can be reduced by nearly 90% by using the tested precipitation chemical PAXXL60respectively nearly 65% by using the tested precipitation chemical PGA according to the lab-scale trials. Thecosts for the chemicals are not included.
168

Energieffektivisering i kommun

Strandh, Andreas January 2011 (has links)
Abstract The Municipality Council decided in 2010 to develop a comprehensive energy efficiency strategy with financial and methodological support from Energimyndigheten (The Swedish Energy Agency). The strategy should include 3 major parts: an inventory of the 2009 energy use defining the current situation, the 2014 and 2020 goals for energy use, and an action plan for goal achievements. According to Energimyndigheten, the strategy must include all municipal administration premises, vehicles, and all majority-owned companies (as Laholmshem, the municipal housing company). The report describes the inventory work in order to obtain the 2009 energy use and the sources of information used. The inventory values are used as the base year values for the 2014 and 2020 goals. The inventory showed that information about the vehicles is dispersed in the municipal administration and no clear structure exists with respect to mileage and fuels used. It was easier to track energy use in municipal administration and residential buildings, since both the municipality administration and Laholmshem use the same statistical monitoring program for energy use. The 2009 inventory showed that the energy use is around the country average, so it is not extremely high or low. The current heating solutions are based on a patchwork of various heat supplies, where natural gas and biogas dominate. This situation appears, since Laholm has no district heating system. The local gas dependence can be both an economic and environmental problem, when gas prices increase and the availability of biogas for heating is reduced in favour of biogas for transportation. The Action Plan describes finally 36 measures that should be elaborated and the implementation process that should involve the municipal politicians, officials and staff. The ambition is that these proposed measures will reduce the energy use with 16% until 2020 and slightly increase the current renewable energy share.
169

Energieffektivisering och solenergi i en universitetsbyggnad : Undervisningshuset och Biblioteket i Uppsala / Efficient Energy Use and Solar Energy in a University Building

Schweitz, Christian January 2011 (has links)
Akademiska hus is a real estate company that specializes in providing Swedish universities with housing facilities for educational and research purposes. The company strives to reduce its use of energy by 40% between the years 2000 and 2025. The aim of this thesis is to determine which measures can be taken to reduce the need of purchased energy in a building that is used by theSwedishUniversityof Agricultural Sciences inUppsala. In order to determine the results of various changes to the building envelope and ventilation system, the building was modelled in the computer simulation program VIP-Energy. Other proposed changes to make the use of energy more efficient concerned water use and lighting. The need of purchased energy can also be reduced by producing electricity or heat on site, using solar energy. Results show that economically viable measures include upgrading windows and faucets, adjusting control systems for ventilation and lighting, and installing roof mounted solar panels for power production. However, the investment in a photovoltaic system requires government grants in order to be profitable, and the system should be grid-connected to make it eligible for green certificates. Through these measures it is possible to reduce the need to purchase electricity for operational uses and energy for heating and cooling by 20%, from 99 kWh/m2,year to 79 kWh/m2,year. This corresponds to a 92 tonne decrease of annual carbon dioxide emissions from energy production and water purification. The total investment cost of 1 066 000 SEK results in a net present value of 883 000 SEK / Byggnadssektorn står för en knapp tredjedel av den totala energianvändningen i Sverige, och för drygt 10 % av de totala utsläppen av växthusgaser. Energianvändning i byggnader omfattas av riksdagens nationella miljökvalitetsmål för god bebyggd miljö, och målet är att den totala specifika energianvändningen ska minska med 20 % till år 2020 och med 50 % till år 2050, jämfört med år 1995. I Boverkets byggregler ställs bland annat krav på nybyggda lokalbyggnaders specifika energianvändning och i klimatzon III, dit Uppsala län räknas, är gränsen högst 90 kWh/m2,år exklusive verksamhetsel. Energi från egen solcells- eller solvärmeanläggning får tillgodo­räknas vid beräkningen av en byggnads specifika energianvändning. Det är möjligt att erhålla investeringsstöd för både solcells- och solvärmeanläggningar, och dessutom är elproduktion från solenergi berättigad till elcertifikat. Syftet med examensarbetet har varit att undersöka möjligheterna att minska behovet att köpt energi i en universitetsbyggnad i Uppsala, genom energieffektivisering och solenergi. Föreslagna åtgärder har bedömts genom att jämföra ändringen i energianvändning och utsläpp av koldioxid, samt genom de ekonomiska nyckeltalen återbetalningstid, kapitalvärde och besparingskostnad. Arbetet har utförts vid Uppsala universitet åt uppdragsgivaren fastighetsbolaget Akademiska hus. Energihushållning är ett av fyra områden som Akademiska hus fokuserar på i sitt miljöarbete, och det långsiktiga målet är att minska den specifika energianvändningen med 40 % mellan år 2000 och år 2025. Den aktuella byggnaden hyrs av Sveriges lantbruksuniversitet och ligger på Campus Ultuna i Uppsala. Byggnaden är indelad i två fastigheter, Undervisningshuset och Biblioteket, och är av suterrängtyp med fyra våningsplan och en bruksarea på drygt 9 000 m2. Lokalerna består främst av föreläsningssalar och biblioteket, men även av kontorsutrymmen, datasalar, sammanträdesrum, pentryn, en aula och allmänna utrymmen. Byggnaden värms av fjärrvärme som i huvudsak produceras från torv- och avfalls-förbränning. Dessutom finns ett system för komfortkyla installerat, som inom kort ska förses med kyla från en fjärrkylaanläggning i nära anslutning till byggnaden. Kylan ska i huvudsak produceras med fjärrvärmedrivna absorptionsvärmepumpar. Ventilationsbehovet tillgodoses med från- och tilluftsfläktar, och återvinning av värme ur frånluften finns. Ventilations-systemet styrs både på tid, temperatur och koldioxidnivå. Belysningen i byggnaden är på många ställen närvarostyrd, men det finns lokaler med enbart tidsstyrning. I dag använder byggnaden årligen cirka 630 MWh värme, 450 MWh verksamhetsel, 150 MWh fastighetsel och 110 MWh kyla. Detta ger en specifik energianvändning på 99 kWh/m2,år exklusive verksamhetsel, och 149 kWh/m2,år inklusive verksamhetsel. För att kartlägga byggnadens energibehov och undersöka olika åtgärders konsekvenser för energianvändningen, har en modell konstruerats i byggnadssimuleringsprogrammet VIP‑Energy. I stor utsträckning har byggnadsspecifika data eller egna antaganden använts vid modelleringen för att ge ett så rättvisande resultat som möjligt. De material som finns fördefinierade i VIP‑Energy har dock använts vid uppbyggnad av väggar, tak och grund. Modellen har justerats så att simuleringsresultaten efterliknat brukardata, och korrektions-faktorer har beräknats för att kompensera för avvikelser. För att ytterligare öka precisionen har zonberäkningsfunktionen i VIP‑Energy använts, och Undervisningshuset och Biblioteket har modellerats separat. Möjliga energieffektiviseringsåtgärder har studerats för sex olika områden – fönster, fasader, tak, ventilation, vattenanvändning och belysning. Solenergi kan tas tillvara i solcells-anläggningar (som producerar el), solvärmeanläggningar (som producerar värme) och solhybridanläggningar (som producerar både el och värme). Inom samtliga nämnda effektiviseringsområden har lönsamma åtgärder funnits, utom för fasader och tak. Av möjliga solenergilösningar är det endast solcellsanläggningar som är lönsamma för den aktuella byggnaden, och endast om investeringsbidrag kan erhållas. Ju större solcellsanläggningen är, desto mer lönsam blir den, och hur stor anläggning som väljs beror därför på Akademiska hus investeringsvilja. Anslutning till elcertifikatsystemet ökar lönsamheten. Totalt kan undersökta åtgärder ge en energibesparing på drygt 360 000 kWh/år, men den ekonomiskt realiserbara andelen utgör 176 000 kWh/år (49 %) av detta. Den totala investeringskostnaden för rekommenderade åtgärder blir 1 066 000 kr, vilket ger ett kapitalvärde på 883 000 kr, och besparingskostnaden blir 0,42 kr/kWh. Dessa åtgärder minskar kostnaden för energi och vatten med 150 000 kr/år, och beräknas ge ytterligare drygt 8 000 kr/år från elcertifikatsystemet. Utan hänsyn till ränta och prisutveckling blir återbetalningstiden sju år. De koldioxidutsläpp som energi- och vattenanvändningen ger upphov till minskar med 92 ton/år, men minskningens storlek är känslig för de antaganden som gjorts när utsläppsfaktorer beräknats. Om ändringen i elanvändning ska antas utgöras av medelel, blir minskningen endast 29 ton/år. Eftersom det rör sig om förändringar i elanvändning har dock marginalel ansetts vara det mest rimliga. Om torv räknas som förnybart istället för fossilt blir den totala utsläppsminskningen 76 ton/år. Vattenanvändningen i byggnaden minskar med 860 m3/år. Byggnadens specifika energianvändning sjunker med 20 % till 79 kWh/m2,år, förutsatt att hela minskningen i elanvändning räknas till fastighetsel. Inklusive verksamhetsel sjunker energianvändningen med 13 % till 129 kWh/m2,år. Åtgärderna ger dock en marginell ökning av fjärrkylabehovet. Det finns inte något direkt samband mellan hög energibesparing och högt kapitalvärde, då exempelvis fönsteråtgärderna ger högst energibesparing men lägst kapitalvärde. Vilka av de rekommenderade åtgärderna som bör prioriteras bestäms av om målet i första hand är att spara energi eller att maximera lönsamheten hos investeringen.
170

Energieffektiviserande åtgärder och klimatutredning av krypgrund / Energy efficiency measures and climate investigation of a crawl space foundation

Janshagen, Marcus, Eliasson, Alexander January 2012 (has links)
I det här examensarbetet behandlas problematiken i krypgrunder i allmänhet och för Kungsmadskolan i Växjö i synnerhet, där undersökning av energiförlust samt en klimatutredning gjorts för nuvarande konstruktion. En lämplig energieffektiviserande åtgärd i form av tilläggsisolering tas fram och dess påverkan på klimatet i krypgrunden utvärderas. Kalkyler innehållande investeringskostnad och årlig besparing presenteras.