• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • 56
  • 5
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 154
  • 154
  • 46
  • 42
  • 42
  • 27
  • 23
  • 19
  • 19
  • 12
  • 12
  • 11
  • 11
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Sistema de eletroestimulação portátil com oito síncronos

Pepino, André Luiz Gonçalves 06 June 2011 (has links)
A Estimulação Elétrica Funcional (EEF), que utiliza pulsos elétricos para a reprodução de movimentos artificialmente, é uma técnica consolidada no tratamento de pacientes em reabilitação. Para tal, são usados equipamentos específicos para a geração destes sinais, chamados de eletroestimuladores. O presente trabalho descreve o desenvolvimento de um eletroestimulador portátil com oito canais independentes e síncronos entre si, permitindo a programação temporal de ativação dos seus canais, o que proporciona a reprodução de movimentos artificiais similares aos reais. O hardware do dispositivo possui dimensões reduzidas (115 mm X 162 mm X 43 mm) e gera estímulos elétricos bifásicos com amplitudes de ±100 mA. Estes pulsos possuem durações de 100 a 800 µs e freqüência de 50 a 1000 Hz. Utilizou-se uma interface em display líquido (LCD) sensível ao toque (touchscreen), para a interação do usuário com o software embarcado, que é responsável por controlar todo o sistema. Um software desktop foi criado para a geração dos programas estimulatórios, contendo também um simulador virtual que por meio de um modelo humano 3D permite ajustes no programa estimulatório antes de executá-lo em um paciente. O equipamento foi desenvolvido de forma a cumprir as normas de segurança elétrica da ABNT referentes a equipamentos eletromédicos para estimulação neuromuscular. Testes in vitro foram feitos seguindo os roteiros descritos nessas normas para garantir a conformidade de seu funcionamento e dos pulsos elétricos fornecidos pelo dispositivo. O equipamento apresentou resultados dentro dos limites de segurança, de temperaturas excessivas, de exatidão de dados de operação, de proteção contra características de saída incorreta e, contra erros humanos. Também, 10 voluntários participaram de testes in vivo com o objetivo de validação clínica do dispositivo. A validação consistiu na comparação de amplitudes de movimento obtidas pelos voluntários em reproduções de movimentos funcionais durante o uso do eletroestimulador desenvolvido e de um comercial. Com erro máximo de 3%, o eletroestimulador desenvolvido foi capaz de executar movimentos funcionais por meio de parâmetros da EEF, podendo ser útil no tratamento de reabilitação física. / The use of electrical pulses for artificial reproduction movements, or Functional Electrical Stimulation (FES), is a consolidated technique for treating patients in rehabilitation. For this use, special instruments are employed to generate the signals, known as electrostimulators. This work describes the development of a portable electrostimulator with eight independent and synchronous channels, allowing a temporal activation program of their channels and making it possible to reproduce artificial movements similar to real ones. The hardware of this device has small dimensions (115 mm X 162 mm X 43 mm) and generates biphasic electrical pulses with maximum amplitudes of ± 100 mA. The pulses have durations from 100 to 800 µs and frequency from 50 to 1000 Hz. Also, there is an interface with a touchscreen liquid crystal display (LCD) for user interaction with the embedded software, which is responsible for controlling the complete system. A desktop software was developed to generate stimulatory programs, containing a virtual simulator that, using a 3D human model, allows adjustments in the stimulatory program before running it on a patient. The instrument complies with the electrical standards of the ABNT relating to electromedical equipment for neuromuscular stimulation. In vitro tests were performed following the rules described in standards to ensure compliance of functioning, and the electrical pulses provided by the device. As a result, the device showed values within the standard limits of safety, excessive temperatures, accuracy of operating data, protection of incorrect output, and human errors. Also, ten volunteers participated of in vivo tests to validate the instrument. The in vivo tests consisted on a comparison of movement ranges obtained by the volunteers in reproduction of functional movements during the use of a commercial electrostimulator and the developed one. With a maximum error of 3%, the developed instrument was capable to perform functional movements, and thus may be useful in treatment of physical rehabilitation.
132

Efeito do tratamento fisioterápico sobre as vibrações das articulações temporomandibulares (ATMs) de pacientes com hipermobilidade condilar

Turcio, Karina Helga Leal [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T20:58:52Z : No. of bitstreams: 1 turcio_khl_me_araca.pdf: 1485831 bytes, checksum: e05ed7c2f7e230e6d774ac50cbabea68 (MD5) / Os ruídos articulares são sinais que caracterizam a presença de algumas desordens temporomandibulares ou instabilidade articular, porém também podem estar presentes em indivíduos sem sintomatologia dolorosa ou disfunção, representando assim um grande desconforto social. O objetivo deste estudo foi quantificar a energia vibratória e o pico de amplitude das vibrações das articulações temporomandibulares com estalo no final da abertura bucal de 15 pacientes com hipermobilidade condilar e avaliar o efeito do tratamento através de exercícios de resistência para o fortalecimento dos músculos da mastigação associados a estímulo elétrico. A intensidade vibratória nos pacientes foi comparada àquela verificada em um grupo de referência constituído de 15 indivíduos assintomáticos antes e após tratamento. Os registros das vibrações articulares foram realizados através de eletrovibratografia, durante os ciclos de abertura e fechamento bucal no momento da consulta, aos 60 e 120 dias de tratamento. Através dos testes t de student e do teste de Tukey verificou-se que as vibrações articulares foram significantemente maiores no final da abertura e início do fechamento bucal tanto no momento da consulta quanto após tratamento. No entanto houve uma redução significante em todas as fases dos ciclos de abertura e fechamento bucal após 120 dias de fortalecimento muscular indicando um sucesso terapêutico. Verificou-se também que mesmo após a significativa redução as vibrações nos pacientes permaneceram mais intensas que no grupo assintomático. / The articular sounds are signs that characterizes a temporomandibular disorder or articular instability. However they also exist in persons without pain or dysfunction, and can represent a social discomfort. The aim of this study was to quantify the vibratory energy and amplitude peak of vibrations from temporomandibular joints with sounds at maximal mouth opening of 15 patients and analyses the effect of treatment with resistance exercises for the strengthening of masticatory muscles associated with electrical stimulation doing a comparison of the vibratory intensities registered in the first contact with the patient and after 60 and 120 days of treatment and also compare this results with non symptomatic ones. Vibratory registers during opening and closing movements were done with electrovibratographic exam. It was verified using 't' student test and Tukey test that articular vibrations were significantly more intense in the end of opening and beginning of closing movements in the consult and after treatment. However vibrations reduced significantly after 120 days of muscular strengthening. Even after this reduction, vibrations of pacients weren't similar to ones of non symptomatic persons.
133

Efeitos do uso da corrente interferencial no tratamento da dor decorrente de microlesão induzida por exercício excêntrico nos músculos flexores e extensores do joelho em humanos

Rocha, Clarice Sperotto dos Santos, Vaz, Marco Aurelio January 2012 (has links)
O objetivo do presente trabalho foi avaliar os efeitos da corrente interferencial na sensibilidade dolorosa e no torque muscular dos músculos flexores e extensores do joelho após a realização de um protocolo de exercícios excêntricos. A amostra foi constituída de 41 indivíduos saudáveis do sexo masculino com idade entre 18 e 33 anos, que foram divididos aleatoriamente em dois grupos experimentais: grupo corrente interferencial (n=21) e grupo placebo (n=20). Para indução da microlesão muscular, ambos os grupos realizaram 100 contrações musculares isocinéticas excêntricas máximas (10 séries de 10 repetições) dos músculos flexores e extensores do joelho na velocidade angular de 60°.s-1. No dia seguinte, os voluntários receberam tratamento com corrente interferencial ou tratamento placebo em ambos os grupos musculares. O tratamento foi realizado durante 30 minutos utilizando-se 4 kHz de frequência portadora (modulação de 80-150 Hz) e 125 μs de duração do pulso. O limiar de dor mecânica, o pico de torque e a concentração da proteína creatina cinase foram avaliados em quatro momentos diferentes: antes da indução da microlesão, imediatamente após o exercício, 24 horas após a indução e após o tratamento com corrente interferencial ou tratamento placebo. Tanto para os músculos flexores quanto extensores do joelho, ambos os grupos experimentais apresentaram uma redução significativa no pico de torque e no limiar de dor mecânica após a realização dos exercícios excêntricos, assim como uma elevação na concentração de proteínas marcadoras de lesão, mostrando que o protocolo de exercícios foi efetivo na indução da microlesão. Após o tratamento, apenas o grupo experimental, que recebeu a corrente interferencial, apresentou um aumento significativo no limiar de dor mecânica para ambos os grupos musculares avaliados, mostrando que a corrente foi efetiva na diminuição da sensibilidade dolorosa. Os valores de torque e a concentração das proteínas não sofreram alteração após o tratamento. Os resultados indicam que a corrente interferencial foi efetiva no tratamento da dor relacionada com microlesão muscular induzida por exercício excêntrico a partir de um aumento do limiar de dor mecânica nos músculos flexores e extensores do joelho. / The goal of the work presented here was to evaluate the effects of the interferential current in the pain sensibility and muscular torque of the flexor and extensor knee muscles after the performance of an eccentric exercise protocol. The sample was comprised of 41 healthy male individuals aged 18 to 33 years old, randomly divided into two experimental groups: interferential current group (n=21) and placebo group (n=20). To induce muscle soreness, both groups performed a hundred maximal isokinetic eccentric muscular contractions (10 series of 10 repetitions) in the flexor and extensor knee muscles, with an angular velocity of 60°.s- 1. On the following day volunteers were treated with interferential current or with the placebo treatment in both muscular groups. Treatment was carried out for 30 minutes using a 4 kHz carrier frequency (80-150 Hz) and a pulse duration of 125 μs. Mechanical pain threshold, peak torque and creatine kinase protein concentration were evaluated at four different times: before muscle soreness induction, immediately after exercise, 24 hours after induction and after the interferential current treatment or the placebo treatment. For both flexor and extensor knee muscles, both experimental groups presented a significant reduction in peak torque and mechanical pain threshold after performing the eccentric exercises, as well as a rise in injurysignaling protein concentration, demonstrating the efficiency of the exercise protocol in inducing muscle soreness. After treatment, only the experimental group that received the interferential current presented significant increases in mechanical pain threshold for both evaluated muscular groups, thus showing that the current was effective in diminishing pain sensitivity. Torque values and protein concentration underwent no changes after the treatment. The results pointed out that the interferential current was effective in the treatment of pain related to muscle soreness induced by eccentric exercise through an increase in mechanical pain threshold in the flexor and extensor knee muscles.
134

Efeitos do uso da corrente interferencial no tratamento da dor decorrente de microlesão induzida por exercício excêntrico nos músculos flexores e extensores do joelho em humanos

Rocha, Clarice Sperotto dos Santos, Vaz, Marco Aurelio January 2012 (has links)
O objetivo do presente trabalho foi avaliar os efeitos da corrente interferencial na sensibilidade dolorosa e no torque muscular dos músculos flexores e extensores do joelho após a realização de um protocolo de exercícios excêntricos. A amostra foi constituída de 41 indivíduos saudáveis do sexo masculino com idade entre 18 e 33 anos, que foram divididos aleatoriamente em dois grupos experimentais: grupo corrente interferencial (n=21) e grupo placebo (n=20). Para indução da microlesão muscular, ambos os grupos realizaram 100 contrações musculares isocinéticas excêntricas máximas (10 séries de 10 repetições) dos músculos flexores e extensores do joelho na velocidade angular de 60°.s-1. No dia seguinte, os voluntários receberam tratamento com corrente interferencial ou tratamento placebo em ambos os grupos musculares. O tratamento foi realizado durante 30 minutos utilizando-se 4 kHz de frequência portadora (modulação de 80-150 Hz) e 125 μs de duração do pulso. O limiar de dor mecânica, o pico de torque e a concentração da proteína creatina cinase foram avaliados em quatro momentos diferentes: antes da indução da microlesão, imediatamente após o exercício, 24 horas após a indução e após o tratamento com corrente interferencial ou tratamento placebo. Tanto para os músculos flexores quanto extensores do joelho, ambos os grupos experimentais apresentaram uma redução significativa no pico de torque e no limiar de dor mecânica após a realização dos exercícios excêntricos, assim como uma elevação na concentração de proteínas marcadoras de lesão, mostrando que o protocolo de exercícios foi efetivo na indução da microlesão. Após o tratamento, apenas o grupo experimental, que recebeu a corrente interferencial, apresentou um aumento significativo no limiar de dor mecânica para ambos os grupos musculares avaliados, mostrando que a corrente foi efetiva na diminuição da sensibilidade dolorosa. Os valores de torque e a concentração das proteínas não sofreram alteração após o tratamento. Os resultados indicam que a corrente interferencial foi efetiva no tratamento da dor relacionada com microlesão muscular induzida por exercício excêntrico a partir de um aumento do limiar de dor mecânica nos músculos flexores e extensores do joelho. / The goal of the work presented here was to evaluate the effects of the interferential current in the pain sensibility and muscular torque of the flexor and extensor knee muscles after the performance of an eccentric exercise protocol. The sample was comprised of 41 healthy male individuals aged 18 to 33 years old, randomly divided into two experimental groups: interferential current group (n=21) and placebo group (n=20). To induce muscle soreness, both groups performed a hundred maximal isokinetic eccentric muscular contractions (10 series of 10 repetitions) in the flexor and extensor knee muscles, with an angular velocity of 60°.s- 1. On the following day volunteers were treated with interferential current or with the placebo treatment in both muscular groups. Treatment was carried out for 30 minutes using a 4 kHz carrier frequency (80-150 Hz) and a pulse duration of 125 μs. Mechanical pain threshold, peak torque and creatine kinase protein concentration were evaluated at four different times: before muscle soreness induction, immediately after exercise, 24 hours after induction and after the interferential current treatment or the placebo treatment. For both flexor and extensor knee muscles, both experimental groups presented a significant reduction in peak torque and mechanical pain threshold after performing the eccentric exercises, as well as a rise in injurysignaling protein concentration, demonstrating the efficiency of the exercise protocol in inducing muscle soreness. After treatment, only the experimental group that received the interferential current presented significant increases in mechanical pain threshold for both evaluated muscular groups, thus showing that the current was effective in diminishing pain sensitivity. Torque values and protein concentration underwent no changes after the treatment. The results pointed out that the interferential current was effective in the treatment of pain related to muscle soreness induced by eccentric exercise through an increase in mechanical pain threshold in the flexor and extensor knee muscles.
135

Efeitos do uso da corrente interferencial no tratamento da dor decorrente de microlesão induzida por exercício excêntrico nos músculos flexores e extensores do joelho em humanos

Rocha, Clarice Sperotto dos Santos, Vaz, Marco Aurelio January 2012 (has links)
O objetivo do presente trabalho foi avaliar os efeitos da corrente interferencial na sensibilidade dolorosa e no torque muscular dos músculos flexores e extensores do joelho após a realização de um protocolo de exercícios excêntricos. A amostra foi constituída de 41 indivíduos saudáveis do sexo masculino com idade entre 18 e 33 anos, que foram divididos aleatoriamente em dois grupos experimentais: grupo corrente interferencial (n=21) e grupo placebo (n=20). Para indução da microlesão muscular, ambos os grupos realizaram 100 contrações musculares isocinéticas excêntricas máximas (10 séries de 10 repetições) dos músculos flexores e extensores do joelho na velocidade angular de 60°.s-1. No dia seguinte, os voluntários receberam tratamento com corrente interferencial ou tratamento placebo em ambos os grupos musculares. O tratamento foi realizado durante 30 minutos utilizando-se 4 kHz de frequência portadora (modulação de 80-150 Hz) e 125 μs de duração do pulso. O limiar de dor mecânica, o pico de torque e a concentração da proteína creatina cinase foram avaliados em quatro momentos diferentes: antes da indução da microlesão, imediatamente após o exercício, 24 horas após a indução e após o tratamento com corrente interferencial ou tratamento placebo. Tanto para os músculos flexores quanto extensores do joelho, ambos os grupos experimentais apresentaram uma redução significativa no pico de torque e no limiar de dor mecânica após a realização dos exercícios excêntricos, assim como uma elevação na concentração de proteínas marcadoras de lesão, mostrando que o protocolo de exercícios foi efetivo na indução da microlesão. Após o tratamento, apenas o grupo experimental, que recebeu a corrente interferencial, apresentou um aumento significativo no limiar de dor mecânica para ambos os grupos musculares avaliados, mostrando que a corrente foi efetiva na diminuição da sensibilidade dolorosa. Os valores de torque e a concentração das proteínas não sofreram alteração após o tratamento. Os resultados indicam que a corrente interferencial foi efetiva no tratamento da dor relacionada com microlesão muscular induzida por exercício excêntrico a partir de um aumento do limiar de dor mecânica nos músculos flexores e extensores do joelho. / The goal of the work presented here was to evaluate the effects of the interferential current in the pain sensibility and muscular torque of the flexor and extensor knee muscles after the performance of an eccentric exercise protocol. The sample was comprised of 41 healthy male individuals aged 18 to 33 years old, randomly divided into two experimental groups: interferential current group (n=21) and placebo group (n=20). To induce muscle soreness, both groups performed a hundred maximal isokinetic eccentric muscular contractions (10 series of 10 repetitions) in the flexor and extensor knee muscles, with an angular velocity of 60°.s- 1. On the following day volunteers were treated with interferential current or with the placebo treatment in both muscular groups. Treatment was carried out for 30 minutes using a 4 kHz carrier frequency (80-150 Hz) and a pulse duration of 125 μs. Mechanical pain threshold, peak torque and creatine kinase protein concentration were evaluated at four different times: before muscle soreness induction, immediately after exercise, 24 hours after induction and after the interferential current treatment or the placebo treatment. For both flexor and extensor knee muscles, both experimental groups presented a significant reduction in peak torque and mechanical pain threshold after performing the eccentric exercises, as well as a rise in injurysignaling protein concentration, demonstrating the efficiency of the exercise protocol in inducing muscle soreness. After treatment, only the experimental group that received the interferential current presented significant increases in mechanical pain threshold for both evaluated muscular groups, thus showing that the current was effective in diminishing pain sensitivity. Torque values and protein concentration underwent no changes after the treatment. The results pointed out that the interferential current was effective in the treatment of pain related to muscle soreness induced by eccentric exercise through an increase in mechanical pain threshold in the flexor and extensor knee muscles.
136

Efeito em curto prazo da corrente interferencial associado a cinesioterapia no tronco de paciente com acidente vascular encefálico

Andrade, Daniela da Costa Maia de 21 February 2018 (has links)
Introduction: Among the main causes of disability associated with stroke, are: impairment of voluntary movements, spasticity, pain and loss of selective activity of muscles responsible for trunk control. The use of interferential current (IFC) in stroke patients has been recently reported in the literature for managing pain and spasticity. Aims: 1. to identify the evidence from studies evaluating the effects of IFC in patients with central neurological diseases (a systematic review); 2. To determine the short-term effect of IF associated with kinesiotherapy on pain of stroke patients; 3. To investigate the short term effects of IFC associated with kinesiotherapy on motor performance and functional gains of the trunk of patients with stroke. Methods: 1) A systematic review of clinical trials on 8 databases (Medline, Scopus, Science Direct, Web of Science, CINAHL, Scielo, Cochrane Central Register and PEDro) was conducted by two investigators by using the following key-words: interferential current OR interferential current therapy OR interferential electrical stimulation OR interferential electrical stimulation therapy OR interferential therapy OR interferential stimulation. The Cochrane collaboration tool was used for methodological quality analysis. 2 and 3) A randomized, double-blinded, placebo-controlled, crossover-type clinical trial was performed. 36 stroke patients were recruited and randomly included in one of two groups: active IFC group (IFC application + kinesiotherapy of trunk) and placebo IFC group (30 minutes of placebo IFC + kinesiotherapy of trunk). Both groups received 10 session of treatment, twice a week, for 60 minutes, with 05 sessions at each treatment group and a washout period of one week between treatments. Results: 1) 2004 studies were found, but only two were included based on the proposed inclusion criteria. After one single session, IFC was effective in reducing pain and spasticity and at improving balance, gait and range of motion of stroke patients. 2 and 3) there was improvement in pain during movement, pain catastrophizing and reaching of the affected member, when comparing pre and post treatment averages. There was no change in fatigue, self-esteem, motivation, trunk control, posture, flexibility and muscle tone in both groups. Conclusion: IFC might have influenced the improvements in trunk control and motor performance of stroke patients when associated with kinesiotherapy. It is recommended that new studies with a higher number of sessions be conducted to better clarify the effects of IFC associated with kinesiotherapy. / Introdução: Entre as principais causas de incapacidades do AVE podemos citar: o comprometimento dos movimentos voluntários, a espasticidade, a dor e a perda da atividade seletiva dos músculos responsáveis pelo controle do tronco. O uso da corrente interferencial (CI) em pacientes com AVE tem sido reportado recentemente na literatura científica, na prática isolada, no tratamento da dor e na espasticidade. Objetivos: 1. Identificar a evidência dos estudos que avaliaram os efeitos da CI em pacientes com doenças neurológicas centrais (revisão sistemática); 2. Determinar o efeito da CI associado a cinesioterapia na dor dos pacientes com AVE; 3. Investigar a performance motora e ganhos funcionais do tronco dos pacientes com AVE após aplicação de CI associado a cinesioterapia. Método: 1) busca sistemática de estudos em 8 bases de dados (Medline, Scopus, Science Direct, Web of Science, CINAHL, Scielo, Cochrane Central Register e PEDro) realizada por dois investigadores, através dos descritores interferential current OR interferential current therapy OR interferential electrical stimulation OR interferential electrical stimulation therapy OR interferential therapy OR interferential stimulation. Para avaliação metodológica desses estudos, foi utilizada a ferramenta da Colaboração Cochrane. 2 e 3) Ensaio clínico randomizado, controlado por placebo e duplamente encoberto, do tipo crossover. Foram recrutados 36 pacientes com AVE, que foram aleatoriamente incluídos em um dos dois grupos de estudo: grupo CI Ativa (aplicação de CI por 30 minutos + cinesioterapia de tronco) e grupo CI Placebo (placebo da CI + cinesioterapia de tronco). Ambos os grupos receberam intervenção por 10 sessões, duas vezes por semana, 60 minutos, sendo 05 sessões para cada forma de tratamento e um período de washout de uma semana. Resultados: 1) Foram encontrados 2004 estudos, porém apenas dois artigos foram incluídos por seguirem os critérios de inclusão propostos. Após administração única, a CI mostrou-se eficaz na redução da dor, da espasticidade e na melhora do equilíbrio, da marcha e da amplitude de movimento de ombro de pacientes pós AVE. 2 e 3). Houve melhora na dor em movimento, catastrofização da dor e no alcance para o lado acometido quando comparadas as médias pré e pós-tratamento. Não houve alteração da fadiga, da autoestima, da motivação, do controle de tronco, da postura, da flexibilidade e do tônus em ambos os grupos. Conclusão: A CI pode ter influenciado a melhora do tronco e performance motora de pacientes pós AVE associado a cinesioterapia. Recomenda-se, assim, a realização de novos estudos com um maior número de sessões para melhor esclarecer os efeitos da CI associada a cinesioterapia. / São Cristóvão, SE
137

Efeito hipoalgésico da corrente alternada de média frequência em quilohertz (Aussie) em indivíduos saudáveis: ensaio clínico randomizado

Agripino, Mayara Ellen de Jesus 03 March 2017 (has links)
Fundação de Apoio a Pesquisa e à Inovação Tecnológica do Estado de Sergipe - FAPITEC/SE / Studies report that alternating current is more effective in promoting analgesia than low frequency pulsed currents. However, the hypoalgesic potential and the clinical use of the medium frequency alternating current in kHz (Aussie) are based on hypothetical mechanisms of action. The present study aimed to investigate the hypoalgesic potential of the Aussie Current (AC) in healthy individuals. Eighty-one healthy subjects underwent electrostimulation by using kilohertz-frequency alternating current for 20 minutes and were randomized into three distinct groups (1 kHz, 4 kHz or placebo). Pressure pain threshold (PPT, algometry), conditioned pain modulation (CPM, ischemic pain in the contralateral upper limb and algometry), temporal summation (TS, algometry) were measured before and after intervention, the level of anxiety (STAI-T and STAI-E), in turn, was measured only at the pre-intervention. At the end of the protocol, subjects were questioned regarding the treatment they received and the comfort during the stimulation (numerical scale) and, similarly, investigators were questioned about their expectation related to subject’s allocation groups. These responses were recorded and used to test the adequacy of the masking procedure regarding the subject and the investigator. The level of anxiety evaluated did not a statistically significant difference between the groups, who received the active AC (1 kHz / 4kHz) or placebo, (p> 0.05). Regarding PPT, there was no statistically significant difference in the active AC 1 kHz, active 4 kHz and placebo groups at any of the moments evaluated. The active group AC 4 kHz presented a statistically significant reduction in the amplification of pain intensity, verified by the reduction of perceived pain intensity, in the tenth (p = 0.02), twentieth (p = 0.01) and thirtieth second (p = 0.001) in the TS test. The active group AC 1 kHz, in turn, presented significant reduction of pain intensity only at the end of the measurement (thirty-second, p = 0.01). In the evaluation of the CPM, there was no significant difference of the PPT, during induction of ischemia, in the AC active groups 4 kHz and active AC 1 kHz, before and after intervention (p> 0.05). However, in the placebo group there was a significant reduction in PPT, only during induced ischemia, both before and after intervention (p = 0.01). Thus, our study provides evidence that kilohertz-frequency AC current, especially when used with an equivalent 4 kHz frequency, presents hypoalgesic effect, having having possible inhibitory action in the Central Nervous System (CNS). / Estudos relatam que a corrente alternada é mais eficaz em promover analgesia que as correntes pulsadas de baixa frequência. Porém, o potencial hipoalgésico e a utilização clínica da corrente alternada de média frequência em kHz (Aussie) são baseados em mecanismos de ação hipotéticos. O presente estudo teve, como objetivo, investigar o potencial hipoalgésico da corrente Aussie (CA) em indivíduos saudáveis. Oitenta e um sujeitos saudáveis foram submetidos à eletroestimulação com corrente alternada de média frequência em quilohertz durante 20 minutos, sendo randomizados em três grupos distintos (1 kHz, 4 kHz ou placebo). Limiar de dor por pressão (LDP, algometria), modulação condicionada da dor (MCD, dor isquêmica no membro superior contralateral e algometria), somação temporal (ST, algometria) foram mensurados antes e após intervenção, o nível de ansiedade (IDATE-T e IDATE-E), por sua vez, foi mensurado apenas no momento pré-intervenção. Ao final do protocolo, os sujeitos foram questionados com relação ao tratamento que receberam e o conforto durante a estimulação (escala numérica) e, similarmente, os avaliadores sobre sua expectativa relacionada ao grupo de alocação dos sujeitos. Estas respostas foram registradas e usadas para testar a adequação do procedimento de mascaramento referente ao sujeito e ao investigador. O nível ansiedade, avaliado no momento pré-intervenção, não diferiu entre os grupos que receberam a CA ativa (1 kHz/ 4 kHz) ou placebo, sendo p>0,05. Em relação ao LDP, não houve diferença estatisticamente significativa nos grupos de intervenção CA ativa 1kHz, ativa 4 kHz e placebo em nenhum dos momentos avaliados. O grupo ativo CA 4 kHz apresentou redução estatisticamente significativa da amplificação da intensidade da dor, verificada pela redução da intensidade de dor percebida, no décimo (p=0,02), vigésimo (p=0,01) e trigésimo segundos (p=0,001), no teste de ST. O grupo ativo CA 1 kHz, por sua vez, apresentou redução significativa da intensidade de dor apenas no final da mensuração (trigésimo segundo; p=0,01). Na avaliação da MCD, não houve diferença significativa do LDP, durante a indução de isquemia, nos grupos CA ativo 4 kHz e CA ativo 1 kHz, no momento antes e após intervenção (p>0,05). No entanto, no grupo placebo, houve redução significativa do LDP, apenas durante a isquemia induzida, comparando pré e pós-intervenção (p=0,01). Dessa forma, o nosso estudo, fornecem evidências de que a corrente aussie, principalmente, quando utilizada com frequência equivalente 4 kHz, apresenta resultados hipoalgésicos, tendo possível ação inibitória no sistema nervoso central (SNC).
138

Influencia da eletroestimulação intravaginal e na qualidade de vida da mulheres com incontinencia urinaria / The influence of intravaginal electrical stimulation on vaginal ecosystem and quality of life on female urinary incontinence

Rett, Mariana Tirolli 13 August 2018 (has links)
Orientador: Paulo Cesar Giraldo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-13T17:48:41Z (GMT). No. of bitstreams: 1 Rett_MarianaTirolli_D.pdf: 1995626 bytes, checksum: 4efa60d32a9f7e4d934df9d4da99bb70 (MD5) Previous issue date: 2009 / Resumo: Objetivos: Avaliar o ecossistema vaginal e a qualidade de vida (QV) de mulheres com incotinência urinária (IU) submetidas a tratamento fisioterápico com eletroestimulção intravaginal (EEIV). Métodos: Estudo de ensaio clínico realizado entre setembro de 2006 a novembro de 2008 envolveu 67 mulheres com queixa clínica de IU. O tratamento fisioterápico consistiu de 8 sessões (2x/semana) de EEIV (frequência=35Hz, largura de pulso=0,5ms e tempo=20min), orientações comportamentais e exercícios de fortalecimento do assoalho pélvico. O ecossistema vaginal foi avaliado quanto ao tipo de flora, inflamação e pH da mucosa vaginal antes e após a EEIV. O conteúdo coletado do terço médio vaginal foi corado pela técnica de Gram e analisado sob microscopia óptica em flora bacilar ou normal, intermediária e, cocóide/ cocobacilar ou vaginose bacteriana (VB). A intensidade da inflamação foi determinada contando-se o número médio de células de defesa (polimorfonucleares neutrófilos e linfócitos) encontradas em 10 campos de grande aumento (400X). A QV foi avaliada pelo questionário "Consultation on Incontinence Questionnaire-Short Form" antes e após o tratamento. Os dados foram coletados pelo mesmo investigador e analisados por apenas um microbiólogo de forma cega. O estudo foi aprovado pelo Comitê de Ética em Pesquisa etodas as pacientes assinaram termo de consentimento livre e esclarecido. Resultados: Foram selecionadas 78 mulheres, sendo 11 excluídas para a análise microbiológica e 6 para análise da QV. Das 67 mulheres incluídas, a média de idade foi de 51,3 (±11,8) anos, a maioria branca, do lar, pós-menopausada e com sintomas de IUM (76,4%) e IUE (23,6%). Antes da EEIV, 43 mulheres apresentaram microbiota normal, 24 intermediária e nenhum caso de VB ou candidíase vaginal (CV). Após as 8 sessões de EEIV não houve mudança significativa da flora vaginal, sendo que das 43 mulheres que apresentaram flora normal, 36 permaneceram na mesma categoria, 5 apresentaram flora intermediária e 2 apresentaram VB. Das 24 identificadas com microbiota intermediária, 15 permaneceram na mesma categoria, 7 foram identificadas com microbiota normal e 2 com VB. O aparecimento de 4 casos de VB foi estatisticamente significativo (p<0,05). A análise do processo inflamatório identificou que 60 mulheres não apresentavam inflamação, 4 tinham inflamação leve/moderada e 3 inflamação intensa. Após o tratamento não houve mudança significativa, sendo que 58 mulheres não apresentavam inflamação, 6 apresentaram inflamação leve/moderada e 3 inflamação intensa. Também não foram encontradas diferenças significativas nos valores do pH antes e após cada sessão de EEIV. Para a avaliação da QV foram incluídas 72 mulheres. Encontrou-se uma redução significativa dos escores da frequência de perda urinária de 3,4(±1,4) para 1,4(±5,9) [p<0,03], da quantidade de perda urinária de 3,6(±1,6) para 2,0(±1,3) [p<0,04] e do impacto da IU na QV de 7,7(±2,4) para 3,8(±2,9) [p<0,001]. O escore total do ICIQ-SF diminuiu de 14,6(±4,2) para 7,2(±4,5) [p<0,001]. Conclusões: O ecossistema vaginal neste estudo não foi significativamente influenciado pela EEIV quanto ao tipo de flora vaginal, inflamação da mucosa vaginal, mudança do pH vaginal e aparecimento de CV, apesar de terem aparecido 4 casos de VB. A EEIV proporcionou uma melhora significativa na QV de mulheres com IU. / Abstract: Objectives: To evaluate vaginal ecosystem and quality of life (QOL) of women submitted to intravaginal electrical stimulation (IVES) as physicaltherapy treatment. Methods: A clinical trial was carried out from September 2006 to November 2008 including 67 women presenting IU as symptom. Physicaltherapy treatment consisted in 8 IVES sessions during 4 weeks (frequency=35Hz, pulse width=0,5ms, duration=20min), pelvic floor muscle exercises (PFME) and behavioral orientation. Vaginal ecosystem was assed concerning type of flora, inflammation and pH before and after treatment. Vaginal bacterioscopy swab was collected from e middle third of the vagina (vaginal smear was collected for subsequent Gram stain). The inflammatory process intensity was determined by the average number of white defense cells (neutrophils and limphocytes) found in 10 observation fields (magnified 400X). Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) was used to asses QoL. All data was collected by a single investigator and analyzed by the same microbiologist. This study was approved by Institutional Ethitics Committee and every patient signed an agreement term. Results: 78 women were selected and 11 were excluded from microbiologic analyzes and 6 from QoL analyses. Of the 67 women included, the mean age was 51.3(±12.2), most were white, housewives, post menopausal, presenting symptoms of MUI (76.4%) and SUI (23.6%). Before IVES 43 women had a normal vaginal flora, 24 presented intermediary flora and none had bacterial vaginoses (BV) or vaginal candidiasis (VC). After 8 sessions of IVES no significant alteration was noticed, 43 were unaltered, 36 remained in the same category, 5 showed intermediary microbiota and 2 were identified as having VB. Of those 24 initially identified as intermediary, 15 remained in the same category, 7 were normal and 2 with VB. Four cases of BV was statistically significant (p<0,05). The inflammatory process analyses identifiyed that 60 women did not present any inflammation, 4 had slight-moderate and 3 showed it as intense. No significant changes in pH were observed in the measurements before and after each IVES session. Also, it was observed a significant reduction in scores of frequency of leakage from 3.4(±1,4) to 1.4(±5.9) [p<0.03], amount of leakage from 3.6(±1.6) to 2.0(±1.3) [p<0.04] and impact of UI in Qol from 7.7(±2.4) to 3.8(±2.9) [p<0.001]. Total score ICIQ-SF decreased from 14.6(±4.2) to 7.2 (±4.5) [p<0.001]. Conclusion: No significant influence was observed in the vaginal ecosystem, inflammatory process, and vaginal pH after IVES, but 4 cases of BV were reported. The IVES provided a significant improvement in QoL of women with UI. / Doutorado / Tocoginecologia / Mestre em Tocoginecologia
139

Efeitos da estimulação magnética transcraniana de repetição nas alucinações auditivas de pacientes com esquizofrenia super-refratária ao tratamento / Effects of repetitive transcranial magnetic stimulation on auditory hallucinations of patients with schizophrenia refractory to treatment

Marina Odebrecht Rosa 04 July 2006 (has links)
Onze pacientes com diagnóstico de esquizofrenia pelo DSM-IV-TR e alucinações auditivas mesmo em uso de clozapina foram distribuídos aleatoriamente para receber estimulação magnética transcraniana de repetição (EMTr) ativa (n=6) ou inativa (n=5) no córtex têmporo-parietal esquerdo. Um total de 160 minutos de EMTr a 1 Hz foi administrada ao longo de 10 dias, 90% do limiar motor, com desenho paralelo, com pacientes e avaliadores cegos, em desenho controlado com grupo inativo. Houve um efeito de grupo significativo nos escores da escala de alucinações (realidade e influência: p=0,0360 e p=0,0493 respectivamente) e no subitem sintomas positivos da PANSS. A EMTr ativa em associação com clozapina pode ser administrada com segurança para tratar as alucinações auditivas. Embora a amostra consistia de pacientes extremamente refratários, estes resultados sugerem haver alguns efeitos da EMTr a 1 Hz no córtex têmporo-parietal esquerdo. / Eleven schizophrenics patients according to DSM-IV-TR criteria and experiencing auditory hallucinations in spite of treatment with clozapine were randomly allocated to receive repetitive transcranial magnetic stimulation (rTMS) (n=6) or sham stimulation (n=5) over left temporo-parietal cortex. A total of 160 minutes of 1 Hz rTMS was administered over 10 days at 90% motor threshold, with patients and raters blind to treatment modality, using a sham-controlled, parallel design. There was a significant group effect for the Auditory Hallucinations Rating Scale scores (reality and attencional salience: p=0.0360 and p=0.0493 respectively) and the sub item positive symptoms of PANSS. Active rTMS in association with clozapine can be administered safely to treat auditory hallucinations. Although the sample consisted of extremely refractory patients, the results suggest some effects of 1 Hz rTMS over Left temporoparietal.
140

Efeito da eletroestimulação nervosa transcutânea no alívio da dor em nulíparas, na fase ativa do trabalho de parto / Effect of transcutaneous nervous electrical Stimulation for pain relief in nulliparous women in active phase of labor

Licia Santos Santana 18 November 2011 (has links)
A eletroestimulação nervosa transcutânea (ENT) é um recurso que consiste em administrar impulsos ou estímulos elétricos de frequência variável, assimétricos ou simétricos de correntes bifásicas através de eletrodos superficiais aplicados sobre a região dolorosa. O objetivo deste estudo foi avaliar o efeito da ENT no alívio da dor na fase ativa da dilatação, no trabalho de parto, e constatar o grau de satisfação das parturientes em relação à experiência vivida durante o estudo. Trata-se de um ensaio clínico randomizado e controlado com 46 parturientes, divididas em grupo controle (GC) e grupo de intervenção (GI). Todas as pacientes eram primigestas, com dilatação cervical de 4 cm, em trabalho de parto espontâneo, com contrações regulares para essa fase, sem uso de drogas ocitócicas ao longo do trabalho de parto, de baixo risco gestacional, com membranas ovulares íntegras e feto único. A aplicação da ENT foi feita pela pesquisadora responsável, fixando dois pares de eletrodos nas regiões paravertebrais, um nas raízes nervosas de T10 a L1 e outro par entre S2 e S4. Os parâmetros utilizados na ENT foram: frequência de 100 Hz, largura de pulso de 100 us, intensidade de acordo com a sensibilidade da paciente e duração da aplicação de 30 minutos contínuos. A avaliação da dor foi realizada imediatamente, antes e após a terapêutica, com a escala categórica numérica (ECN), a escala visual analógica (EVA), o diagrama corporal da localização e Questionário McGill na forma reduzida. No puerpério, além dessas avaliações, o grau de satisfação da paciente com relação à intervenção e a presença de um profissional de saúde durante a fase ativa do trabalho de parto foram pesquisados. Os resultados mostraram que houve diferenças estatísticas significantes entre os dois grupos estudados, com relação à intensidade da dor, após a aplicação da ENT, com apenas 34% das pacientes do GI mantendo a classificação da dor como 7 ou mais, em contraste com 83% das pacientes do GC. Por outro lado, não houve diferenças estatísticas em relação à localização da dor, após a aplicação da ENT. As parturientes do GI ficaram mais satisfeitas com a experiência vivida e com o suporte contínuo recebido, durante o período estudado. Os resultados maternos e perinatais foram semelhantes nos dois grupos estudados. Os resultados encontrados demonstram que a aplicação da ENT, no início da fase ativa do trabalho de parto, alivia a dor das parturientes. Além disso, a presença de suporte contínuo exerce efeito positivo sobre as pacientes submetidas a essa intervenção / The transcutaneous electrical nervous stimulation (TENS) is a resource that consists of administering electrical impulses or stimuli of variable frequency, asymmetric or symmetric of two-phase chains to superficial electrodes applied on the painful region. The objective of this study was to evaluate the effect of TENS for pain relief during the active phase of cervix dilation in labor and to assess the degree of maternal satisfaction related to the experience during the study. This is a randomized controlled trial with 46 pregnant women, divided into control group (CG) and intervention group (IG). All patients were primiparous with cervical dilation of 4 cm in spontaneous labor with regular contractions for this phase without the use of oxytocic drugs during labor, lowrisk pregnant women with intact membranes and a single fetus. The application of the TENS was made by the researcher in charge, setting two pairs of electrodes in the paravertebral regions, at the level of the nerve roots from T10 to L1 and another pair between S2 to S4. The parameters used in TENS were: frequency 100 Hz, pulse width 100 us, intensity according to the sensitivity of the patient and duration of application of 30 continuous minutes. Pain assessment was performed immediately before and after therapy with the numerical categorical scale (ECN), the visual analogue scale (VAS), the body chart for pain location and the reduced form of McGill Questionnaire. In the puerperium, in addition to these assessments, the level of patient satisfaction related to the intervention and the presence of a health professional during the active phase of labor has been searched. The results showed statistically significant differences between the two groups regarding the intensity of pain following the implementation of the TENS, with only 34% of IG patients maintaining the score of pain as 7 or more, in contrast to 83% of CG patients. On the other hand, no statistical differences related to the location of the pain after the application of TENS. The mothers of the IG were more satisfied with the experience and the ongoing support received during the study period. The maternal and perinatal outcomes were similar in both groups. The results show that the application of TENS in the early active phase of labor relieves maternal pain. Moreover, the presence of ongoing support has a positive effect on patients undergoing this intervention

Page generated in 0.1091 seconds