• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 19
  • 11
  • 1
  • Tagged with
  • 55
  • 41
  • 29
  • 26
  • 26
  • 26
  • 21
  • 17
  • 8
  • 8
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Design of an Energy-Aware Unequal Clustering Protocol based on Fuzzy Logic for Wireless Sensor Networks

Kheriji, Sabrine 25 February 2021 (has links)
Energy consumption is a major concern in Wireless Sensor Networks (WSNs) resulting in a strong demand for energy-aware communication technologies. In this context, several unequal cluster-based routing protocols have been proposed. However, few of them adopt energetic analysis models for the calculation of the optimal cluster radius and several protocols can not realize an optimal workload balance between sensor nodes. In this scope, the aim of the dissertation is to develop a cluster-based routing protocol for improving energy efficiency in WSN. We propose a Fuzzy-based Energy-Aware Unequal Clustering algorithm (FEAUC) with circular partitioning to balance the energy consumption between sensor nodes and solve the hotspot problem created by a multi-hop communication. The developed FEAUC involves mainly four phases: An off-line phase, a cluster formation phase, a cooperation phase and data collection phase. During the off-line phase, an energy analysis is performed to calculate the radius of each ring and the optimal cluster radius per ring. The cluster formation phase is based on a fuzzy logic approach for the cluster head (CH) selection. The cooperation phase aims to define an intermediate node as a router between different CHs. While, in the data collection phase, transmitting data packet from sensor nodes to their appropriate CHs is defined as an intra-cluster communication, and transmitting data from one CH to another until reaching the base station, is defined as an inter-cluster communication. The feasibility of the developed FEAUC is demonstrated by elaborating comparison with selected referred unequal clustering algorithms considering different parameters, mainly, the energy consumption, battery lifetime, time to first node shuts down (FND), time of half of nodes off-line (HND) and time to last node dies (LND). Although, the developed FEAUC is intended to enhance the network lifetime by distributing the large load of CH tasks equally among the normal nodes, running the clustering process in each round is an additional burden, which can significantly drain the remaining energy. For this reason, the FEAUC based protocol has been further developed to become a fault tolerant algorithm (FEAUC-FT). It supports the fault tolerance by using backup CHs to avoid the re-clustering process in certain rounds or by building further routing paths in case of a link failure between different CHs. The validation of the developed FEAUC in real scenarios has been performed. Some sensor nodes, powered with batteries, are deployed in a circular area forming clusters. Performance evaluations are carried out by realistic scenarios and tested for a real deployment using the low-power wireless sensor node panStamp. To complete previous works, as a step of proof of concept, a smart irrigation system is designed, called Air-IoT. Furthermore, a real-time IoT-based sensor node architecture to control the quantity of water in some deployed nodes is introduced. To this end, a cloud-connected wireless network to monitor the soil moisture and temperature is well-designed. Generally, this step is essential to validate and evaluate the proposed unequal cluster-based routing algorithm in a real demonstrator. The proposed prototype guarantees both real-time monitoring and reliable and cost-effective transmission between each node and the base station.:1 Introduction 2 Theoretical background 3 State of the art of unequal cluster-based routing protocols 4 FEAUC: Fuzzy-based Energy-Aware Unequal Clustering 5 Experimental validation of the developed unequal clustering protocol 6 Real application to specific uses cases 7 Conclusions and future research directions / Der Energieverbrauch ist ein Hauptanliegen in drahtlosen Sensornetzwerken (WSNs), was zu einer starken Nachfrage nach energiebewussten Kommunikationstechnologien führt. In diesem Zusammenhang wurden mehrere ungleiche clusterbasierte Routing-Protokolle vorgeschlagen. Allerdings verwenden nur die wenigsten energetische Analysemodelle für die Berechnung des optimalen Cluster-Radius, und mehrere Protokolle können keine optimale Auslastungsbalance zwischen Sensorknoten realisieren. In diesem Zusammenhang ist es das Ziel der Dissertation, ein clusterbasiertes Routing-Protokoll zur Verbesserung der Energieeffizienz im WSN zu entwickeln. Wir schlagen einen Fuzzy-basierten Energy-Aware Unequal Clustering-Algorithmus (FEAUC) mit zirkulärer Partitionierung vor, um den Energieverbrauch zwischen Sensorknoten auszugleichen und das durch eine Multi-Hop-Kommunikation entstehende Hotspot-Problem zu lösen. Der entwickelte FEAUC umfasst hauptsächlich vier Phasen: Eine Offline-Phase, eine Clusterbildungsphase, eine Kooperationsphase und eine Phase der Datensammlung. Während der Offline-Phase wird eine Energieanalyse durchgeführt, um den Radius jedes Ringes und den optimalen Cluster- Radius pro Ring zu berechnen. Die Clusterbildungsphase basiert auf einem Fuzzy-Logik-Ansatz für die Clusterkopf (CH)-Auswahl. Die Kooperationsphase zielt darauf ab, einen Zwischenknoten als einen Router zwischen verschiedenen CHs zu definieren. In der Datensammelphase wird die Übertragung von Datenpaketen von Sensorknoten zu ihren entsprechenden CHs als eine Intra-Cluster-Kommunikation definiert, während die Übertragung von Daten von einem CH zu einem anderen CH bis zum Erreichen der Basisstation als eine Inter-Cluster-Kommunikation definiert wird. Die Machbarkeit des entwickelten FEAUC wird durch die Ausarbeitung eines Vergleichs mit ausgewählten referenzierten ungleichen Clustering-Algorithmen unter Berücksichtigung verschiedener Parameter demonstriert, hauptsächlich des Energieverbrauchs, der Batterielebensdauer, der Zeit bis zum Abschalten des ersten Knotens (FND), der Zeit, in der die Hälfte der Knoten offline ist (HND) und der Zeit bis zum letzten Knoten stirbt (LND). Obwohl mit dem entwickelten FEAUC die Lebensdauer des Netzwerks erhöht warden soll, indem die große Last der CH-Aufgaben gleichmäßig auf die übrigen Knoten verteilt wird, stellt die Durchführung des Clustering-Prozesses in jeder Runde eine zusätzliche Belastung dar, die die verbleibende Energie erheblich entziehen kann. Aus diesem Grund wurde das auf FEAUC basierende Protokoll zu einem fehlerto-leranten Algorithmus (FEAUC-FT) weiterentwickelt. Er unterstützt die Fehlerto-leranz durch die Verwendung von Backup-CHs zur Vermeidung des Re-Clustering-Prozesses in bestimmten Runden oder durch den Aufbau weiterer Routing-Pfade im Falle eines Verbindungsausfalls zwischen verschiedenen CHs. Die Validierung des entwickelten FEAUC in realen Szenarien ist durchgeführt worden. Einige Sensorknoten, die mit Batterien betrieben werden, sind in einem kreisförmigen Bereich angeordnet und bilden Cluster. Leistungsbewertungen warden anhand realistischer Szenarien durchgeführt und für einen realen Einsatz unter Verwendung des drahtlosen Low-Power-Sensorknoten panStamp getestet. Zur Vervollständigung früherer Arbeiten wird als Schritt des Proof-of-Concept ein intelligentes Bewässerungssystem mit der Bezeichnung Air-IoT entworfen. Darüber hinaus wird eine IoT-basierte Echtzeit-Sensorknotenarchitektur zur Kontrolle derWassermenge in einigen eingesetzten Knoten eingeführt. Zu diesem Zweck wird ein mit der Cloud verbundenes drahtloses Netzwerk zur Überwachung der Bodenfeuchtigkeit und -temperatur gut konzipiert. Im Allgemeinen ist dieser Schritt unerlässlich, um den vorgeschlagenen ungleichen clusterbasierten Routing-Algorithmus in einem realen Demonstrator zu validieren und zu bewerten.Der vorgeschlagene Prototyp garantiert sowohl Echtzeit-Überwachung als auch zuverlässige und kostengünstige Übertragung zwischen jedem Knoten und der Basisstation.:1 Introduction 2 Theoretical background 3 State of the art of unequal cluster-based routing protocols 4 FEAUC: Fuzzy-based Energy-Aware Unequal Clustering 5 Experimental validation of the developed unequal clustering protocol 6 Real application to specific uses cases 7 Conclusions and future research directions
52

Chemnitzer Linux-Tage 2010: Tagungsband – 13. und 14. März 2010

Demierre, Andéol, Eggers, Monika, Garbe, Anselm R., Groß, Thomas, Jaenisch, Volker, Jung, Marco, Knopper, Klaus, Lang, Jens, Luithardt, Wolfram, Noble, Howard, Obst, Marcus, Pucklitzsch, Thomas, Schlittermann, Heiko, Schumacher, Stefan, Seidel, Philipp, Spillner, Josef, Tang, Kang, Walle, Bernhard, Wetzel, Ulrich 16 April 2010 (has links)
Die Chemnitzer Linux-Tage fanden am 13. und 14. März 2010 auf dem Campus der Technischen Universität Chemnitz statt. Neben den Präsentationen im Foyer zogen vor allem die Vorträge über 2500 Besucher zur 12. Auflage der Veranstaltung. Der Band vereint den Inhalt von 15 Hauptvorträgen und die Abstrakts von 76 weiteren Beiträgen und stellt damit einen Überblick über das weit gefächerte Programm der Veranstaltung dar. / The Chemnitz Linux Days took place at the campus of the Chemnitz University of Technology. Besides the presentations at the foyer the lectures were first of all attractive for more than 2.500 visitors. This volume contains the content of 15 main lectures and abstracts of 76 further talks and hence gives a survey of the broadly based program of this event.
53

Thermal room modelling adapted to the test of HVAC control systems

Riederer, Peter 28 January 2002 (has links)
Room models, currently used for controller tests, assume the room air to be perfectly mixed. A new room model is developed, assuming non-homogeneous room conditions and distinguishing between different sensor positions. From measurement in real test rooms and detailed CFD simulations, a list of convective phenomena is obtained that has to be considered in the development of a model for a room equipped with different HVAC systems. The zonal modelling approach that divides the room air into several sub-volumes is chosen, since it is able to represent the important convective phenomena imposed on the HVAC system. The convective room model is divided into two parts: a zonal model, representing the air at the occupant zone and a second model, providing the conditions at typical sensor positions. Using this approach, the comfort conditions at the occupant zone can be evaluated as well as the impact of different sensor positions. The model is validated for a test room equipped with different HVAC systems. Sensitivity analysis is carried out on the main parameters of the model. Performance assessment and energy consumption are then compared for different sensor positions in a room equipped with different HVAC systems. The results are also compared with those obtained when a well-mixed model is used. A main conclusion of these tests is, that the differences obtained, when changing the position of the controller's sensor, is a function of the HVAC system and controller type. The differences are generally small in terms of thermal comfort but significant in terms of overall energy consumption. For different HVAC systems the cases are listed, in which the use of a simplified model is not recommended. This PhD has been submitted in accordance to the conditions for attaining both the French and the German degree of a PhD, on a co-national basis, in the frame of a statement of the French government from January 18th, 1994. The research has been carried out in the Automation and Energy Management Group (AGE), Department of Sustainable Development (DDD), at the "Centre Scientifique et Technique du Bâtiment" (CSTB) in Marne la Vallée, France, in collaboration with the "Centre Energétique" (CENERG) at the "Ecole Nationale Supérieure des Mines de Paris" (ENSMP), Paris, France and the Technical University of Dresden (TUD), Germany.
54

Vom Institut für landwirtschaftlichen Transport Meißen zum Forschungszentrum für Mechanisierung und Energieanwendung in der Landwirtschaft in der Akademie der Landwirtschaftswissenschaften (1960–1992): aus heutiger Sicht: eine „Bundesforschungseinrichtung“

10 July 2020 (has links)
Über 30 Jahre existierte in Meißen in der DDR eine Forschungseinrichtung für den landwirtschaftlichen Transport. Im Laufe der Zeit wurde das Forschungs- und Entwicklungsgebiet um Umschlag und Lagerung und schließlich um die Energieanwendung in der Landwirtschaft erweitert. Die Forschungen in Meißen zeichneten sich durch die weitestgehend einheitliche Betrachtung von Ökonomie, Technologie, Technik, Betriebs- und Volkswirtschaft aus. Dabei wurde Wert darauf gelegt, die Ergebnisse mit Partnern aus der Praxis und anderen Verfahrensinstituten ständig zu diskutieren und deren Wünsche zu berücksichtigen. Das heißt auch, dass die Forschung sehr praxisnah ausgelegt war. Schwerpunkte waren sowohl neue technische Entwicklungen für den TUL-Prozess in Pflanzen- und Tierproduktion als auch Umsetzungsaktivitäten für Geräte in den Rationalisierungsmittelbau. Die Überleitung der Ergebnisse war in den letzten Jahren jedoch nicht befriedigend. Die Darstellungen zu Meißen werden durch Beiträge zu den Betriebsteilen des FZM, zur Außenstelle Dresden und zu den vorgesetzten Stellen ergänzt.
55

Assessing the potential of fuel saving and emissions reduction of the bus rapid transit system in Curitiba, Brazil

Dreier, Dennis January 2015 (has links)
The transport sector contributes significantly to global energy use and emissions due to its traditional dependency on fossil fuels. Climate change, security of energy supply and increasing mobility demand is mobilising governments around the challenges of sustainable transport. Immediate opportunities to reduce emissions exist through the adoption of new bus technologies, e.g. advanced powertrains. This thesis analysed energy use and carbon dioxide (CO2) emissions of conventional, hybrid-electric, and plug-in hybrid-electric city buses including two-axle, articulated, and biarticulated chassis types (A total of 6 bus types) for the operation phase (Tank-to-Wheel) in Curitiba, Brazil. The systems analysis tool – Advanced Vehicle Simulator (ADVISOR) and a carbon balance method were applied. Seven bus routes and six operation times for each (i.e. 42 driving cycles) are considered based on real-world data. The results show that hybrid-electric and plug-in hybrid-electric two-axle city buses consume 30% and 58% less energy per distance (MJ/km) compared to a conventional two-axle city bus (i.e. 17.46 MJ/km). Additionally, the energy use per passenger-distance (MJ/pkm) of a conventional biarticulated city bus amounts to 0.22 MJ/pkm, which is 41% and 24% lower compared to conventional and hybrid-electric two-axle city buses, respectively. This is mainly due to the former’s large passenger carrying capacity. Large passenger carrying capacities can reduce energy use (MJ/pkm) if the occupancy rate of the city bus is sufficient high. Bus routes with fewer stops decrease energy use by 10-26% depending on the city bus, because of reductions in losses from acceleration and braking. The CO2 emissions are linearly proportional to the estimated energy use following from the carbon balance method, e.g. CO2 emissions for a conventional two-axle city bus amount to 1299 g/km. Further results show that energy use of city bus operation depends on the operation time due to different traffic conditions and driving cycle characteristics. An additional analysis shows that energy use estimations can vary strongly between considered driving cycles from real-world data. The study concludes that advanced powertrains with electric drive capabilities, large passenger carrying capacities and bus routes with a fewer number of bus stops are beneficial in terms of reducing energy use and CO2 emissions of city bus operation in Curitiba.

Page generated in 0.0615 seconds