• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 16
  • 6
  • Tagged with
  • 49
  • 20
  • 16
  • 16
  • 14
  • 12
  • 11
  • 11
  • 9
  • 9
  • 8
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Mesure de la dose physique par lms radiochromiques et simulation Monte Carlo pour l'hadronthérapie

Zahra, Mohamad Nabil 25 June 2010 (has links) (PDF)
En raison des forts gradients de dose générés par les interactions des particules avec la matière, les traitements par hadronthérapie nécessitent un contrôle très précis de la dose délivrée au patient. Les codes Monte Carlo représentent des outils indispensables dans la validation des systèmes de planification de traitement utilisé en clinique. Nous nous intéressons dans cette thèse au calcul de la dose physique à l'aide des simulations Monte Carlo Geant4/Gate. Nous étudions l'ajustement de plusieurs paramètres qui peuvent influencer la précision du calcul de dose requise en clinique (2%, 2mm) pour un faisceau d'ions carbone de 300 MeV/u dans l'eau. Ces paramètres sont : le seuil de production des particules secondaires et la taille maximale d'un segment de la trace de particule. Les critères de tolérance sur la valeur et la localisation de la dose sont fixés de manière à avoir le meilleur compromis en termes de distribution spatiale et de temps de calcul. Nous proposons ici des paramètres permettant d'atteindre ces critères de précision. Dans la deuxième partie du travail, nous étudions la réponse des films radiochromiques MDv2-55 pour le contrôle qualité des faisceaux d'ions carbone et protons. Nous avons en particulier observé et étudié l'effet de saturation de ces films dosimétriques pour les irradiations à TEL élevés (≥ 20 KeV/µm) dans des milieux homogènes et hétérogènes. Cet effet est dû à la forte densité d'ionisation autour de la trace de particule. Nous avons proposé et développé un modèle appelé " RADIS RAdiochromic films Dosimetry for Ions using Simulations " qui permet de prédire la réponse de ces films avec la prise en compte de cet effet de saturation. Ce modèle est basé sur la réponse des films en photons et la saturation des films à des dépôts d'énergies linéïques élevés calculée par Monte Carlo. Plusieurs types de faisceaux ont été étudiés : ions carbone, protons et photons à différentes énergies. Ces expérimentations ont été menées au Grand Accélérateur National d'Ions Lourds (GANIL), au Centre de protonthérapie d'Orsay (CPO), au Centre A. Lacassagne (CAL) et au Centre Léon Bérard (CLB). A l'aide du modèle, nous pouvons ainsi reproduire la densité optique des films le long du profil de Bragg pour tous les faisceaux avec une précision meilleure que 2%.
12

Planification inverse de la dose en hadronthérapie : prise en compte de la qualité du rayonnement pour une optimisation de la dose biologique

Smekens, François 02 December 2011 (has links) (PDF)
L'hadronthérapie est une modalité d'irradiation récente particulièrement attractive. Les ions, par leur profil caractéristique de dépôt de dose dans la matière et leur efficacité biologique accrue, sont des particules parfaitement adaptées pour le traitement du cancer. C'est une modalité émergente et les travaux de recherche et de développement qui en font l'objet se poursuivent de manière soutenue. Cependant, il n'existe à ce jour aucun outil permettant de quantifier pour le patient le gain clinique associé aux améliorations proposées, comme l'apport d'une gantry par exemple. Nous proposons dans ce travail de concevoir un module de planification inverse du traitement pour un but prospectif. Détachée des contraintes usuelles de précision et de temps de calcul, notre méthode d'optimisation se base sur un algorithme génétique afin d'approcher d'une solution globale vis-à-vis d'un grand nombre de paramètres balistiques (champs d'irradiation libres) et en associant les diverses régions d'intérêt dosimétrique. La stratégie d'optimisation retenue est progressivement complexifiée afin de prendre en compte de manière efficace les différents enjeux de la planification. La robustesse du plan vis-à-vis des incertitudes inhérentes au traitement, primordiale en hadronthérapie, est évaluée. Dans toutes les situations testées, il apparaît que l'inclusion dans l'optimisation de paramètres habituellement fixés manuellement permet une amélioration de la qualité de traitement. Nous proposons au terme de cette étude un outil prospectif d'optimisation au réglage simple et capable de mener des études comparées sur la pertinence de nouvelles modalités d'irradiation.
13

Utilisation d'un modèle microdosimétrique cinétique (MKM) pour l'interprétation d'irradiations cellulaires dans le cadre de l'hadronthérapie : Application de simulations Monte‐Carlo.

Dabli, Djamel 10 February 2010 (has links) (PDF)
L'hadronthérapie est une technique de traitement de cancer basée sur l'utilisation de particules lourdes chargées. Les caractéristiques physiques de ces particules permettent un ciblage plus précis des tumeurs et une efficacité biologique supérieure à celle des photons et des électrons. Ce travail de thèse traite la problématique de la modélisation des effets biologiques induits par ce type de particules. Une partie de ce travail est consacrée à l'analyse de l'outil de simulation Monte‐Carlo " Geant4 ", utilisé pour simuler la phase physique de l'interaction des particules avec le milieu biologique. Nous avons évalué la capacité de " Geant4 " à simuler la distribution microscopique des dépôts d'énergie des particules chargées et confronté ces résultats à ceux d'un autre code de simulation dédié aux applications de radiobiologie. L'autre partie du travail est dédiée à l'étude de deux modèles radiobiologiques basés sur deux approches différentes qui sont le modèle LEM (Local Effect Model) basé sur une approche de trace amorphe et le modèle MKM (Microdosimetric Kinetic Model) basé sur une approche microdosimétrique. Une analyse théorique des deux modèles est effectuée ainsi qu'une comparaison de leurs concepts. Ensuite, nous nous sommes focalisé sur le modèle microdosimétrique " MKM " que nous avons analysé de manière plus approfondie. Enfin, nous avons appliqué le modèle MKM pour reproduire les résultats expérimentaux d'irradiation cellulaire obtenus au GANIL avec des ions carbone et argon sur des cellules tumorales (lignées SCC61 et SQ20B) de radiosensibilité différente.
14

Optimisation de la trajectoire du patient dans les centres de radiothérapie ou d'hadronthérapie / Care-Trajectory optimization in radiotherapy and hadrontherapy facilities

Jacquemin, Yoan 25 October 2011 (has links)
L’optimisation de la planification des traitements par rayons ionisants est bénéfique tant aux patients qu’aux structures de soins bien que particulièrement difficile du fait de la rareté des ressources et de l'importante répétition des séances. Face à cette problématique, un modèle d'optimisation linéaire à nombres entiers a été créé permettant de planifier des protocoles de traitement complexes tout en prenant en compte la disponibilité des patients ainsi que des radiothérapeutes qui les suivent avec pour résultat une amélioration significative des performances sur des indicateurs couvrant les ressources humaines et matérielles ainsi que les délais de prise en charge. De plus nous avons développé des solutions adaptées à des contextes concrets : i) une planification heuristique de la trajectoire des patients au sein du Centre de Protonthérapie d’Orsay (CPO) assortie d'indicateurs de performances, et ii) une adaptation au monde hospitalier de la solution industrielle de planification PREACTOR permettant de conserver la finesse obtenue dans les modélisations linéaires tout en tirant parti des capacités de résolution des heuristiques complexes intégrées à PREACTOR / Ionizing therapy treatment scheduling optimization can improve both patients’ care and care structures’ efficiency. Despite its complexity, mainly because of scarce resources and essential care activities’ repetition, we designed a linear programming model which allows scheduling complex treatment protocols better than existing models on several performance indicators regarding material and human resources while minimizing waiting times and taking into account both patients’ and radiotherapists’ availabilities. Furthermore, we developed two practical applications of heuristic scheduling methods : i) a constructive heuristic scheduling model for the Protontherapy Center of Orsay (CPO) able to plan whole care trajectory base on available resources and ii) an healthcare adaptation of the industrial scheduling platform PREACTOR which achieve linear model's precision resolved through complex heuristics from PREACTOR
15

Charged particle therapy, ion range verification, prompt radiation / Mesures physiques pour la vérification du parcours des ions en hadronthérapie

Testa, Mauro 14 October 2010 (has links)
Cette thèse porte sur les mesures expérimentales des γ-prompts créés lors de la fragmentation du faisceau d'ions carbone en hadronthérapie. Deux expériences ont été effectuées aux laboratoires GANIL et GSI avec des ions 12C6+ de 95MeV/u et 305MeV/u irradiant une cible d'eau ou de PMMA. Dans les deux expériences une nette corrélation a été obtenue entre le parcours des ions carbone et le profil longitudinal des γ- prompts. Une des plus grandes difficultés de ces mesures vient de la discrimination entre le signal des γ-prompts (qui est corrélé avec le parcours des ions) et un important bruit de fond dû aux neutrons (non corrélé au parcours). Deux techniques sont employées pour effectuer la discrimination entre γ et neutrons: le temps de vol (TDV) et la discrimination par forme de signal (DFS). Le TDV a permis de démontrer la corrélation entre la production de γ-prompts et le parcours des ions. La DFS a fourni des informations précieuses pour la compréhension des caractéristiques des spectres en TDV. Dans ce travail on a démontré qu'un système de détection de γ-prompt collimaté, basé sur la technique du temps de vol, peut permettre une vérification en temps réel de la position du Pic de Bragg en conditions cliniques. Dans la dernière partie de la thèse, un travail de simulation a été effectué à l'aide du code de simulation Geant4 pour évaluer l'influence des principaux paramètres du design d'un dispositif de multi-détecteurs et multicollimateurs sur la résolution spatiale et l'efficacité atteignable par une Camera γ-Prompt. Plusieurs configurations géométriques ont été étudiées de façon systématique et les principales contraintes du design sont analysées. / This PhD thesis reports on the experimental investigation of the prompt photons created during the fragmentation of the carbon beam used in particle therapy. Two series of experiments have been performed at the GANIL and GSI facilities with 95 MeV/u and 305 MeV/u 12C6+ ion beams stopped in PMMA and water phantoms. In both experiments a clear correlation was obtained between the C-ion range and the prompt photon profile. A major issue of these measurements is the discrimination between the prompt photon signal (which is correlated with the ion path) and a vast neutron background uncorrelated with the Bragg-Peak position. Two techniques are employed to allow for this photon-neutron discrimination: the time-of-flight (TOF) and the pulse-shape-discrimination (PSD). The TOF technique allowed demonstrating the correlation of the prompt photon production and the primary ion path while the PSD technique brought great insights to better understand the photon and neutron contribution in TOF spectra. In this work we demonstrated that a collimated set-up detecting prompt photons by means of TOF measurements, could allow real-time control of the longitudinal position of the Bragg-peak under clinical conditions. In the second part of the PhD thesis a simulation study was performed with Geant4 Monte Carlo code to assess the influence of the main design parameters on the efficiency and spatial resolution achievable with a multidetector and multi-collimated Prompt Gamma Camera. Several geometrical configurations for both collimators and stack of detectors have been systematically studied and the considerations on the main design constraints are reported.
16

Development of platinum based nanoparticles to enhance cancer cell killing by gamma rays and carbon ion radiation / Développement de nanoparticules à base de platine visant à améliorer la destruction de cellules cancéreuses par des rayons gamma et par ions carbone

Salado Leza, Daniela 25 November 2016 (has links)
La radiothérapie basée sur l'utilisation des photons de haute énergie (rayons X) est l'approche la plus courante dans le traitement du cancer. Toutefois, elle est limitée par la tolérance des tissus sains. Par conséquent, il est d'un intérêt majeur de développer de nouvelles techniques et protocoles pour améliorer le ciblage dans les tumeurs. Dans cette perspective, la hadronthérapie (irradiation de la tumeur par des protons ou des ions carbone) est considérée comme l'une des techniques les plus prometteuses car le dépôt d'énergie est maximum en fin de parcours, ce qui permet de cibler la tumeur. Pourtant, l’utilisation de cette modalité reste limitée du fait de la dose reçue par les tissus sains situés à l'entrée du faisceau.Pour améliorer les performances des thérapies par radiation, une nouvelle stratégie basée sur la combinaison de nanoparticules métalliques (nano-médecine) avec des rayonnements ionisants a été développée par le groupe. En effet, les nanoparticules ont une chimie de surface remarquable qui permet de les fonctionnaliser avec des ligands qui les rendent plus futiles et moins reconnus des macrophages afin de les concentrer dans les tumeurs.Le but de mon travail a été de développer des nanoparticules à base de platine (NPs de platine pelylée et des nanoparticules bimétalliques) visant à améliorer l’effet des rayonnements ionisants (photons et ions carbone) dans les cellules.Une méthode originale de synthèse en une seule étape combinant la radiolyse et la PEGylation in situ a été optimisée. Cette méthode a permis d’obtenir des NPs stables, de taille homogène (cœur métallique proche de 3 nm).L'impact biologique de ces nouvelles NPs a été évalué sur deux lignées de cellules cancéreuses humaines. Il a été observé que les NPs, non-toxiques, ont un mode d’internalisation qui dépend de la lignée cellulaire. Celles-ci sont, dans tous les cas, localisées exclusivement dans le cytoplasme. Les NPs de platine développées dans ce travail permettent d’amplifier significativement la destruction des cellules cancéreuses, en particulier lorsqu’un faisceau médical d’ions carbone est utilisé comme rayonnement. Les mécanismes moléculaires à l’origine de cet effet ont été étudiés grâce à l’utilisation d’une nanosonde biologique. Ces expériences ont montré que les NPs sont responsables de l’augmentation de dommages nanométriques, qui peuvent être létaux pour les cellules. Cet effet est attribué à des processus électroniques d’activation et de reneutralisation de la NP qui engendre une forte perturbation dans le volume nanométrique qui l’entoure tel que la production groupée de radicaux fortement réactifs et toxiques.En conclusion, ce travail à l’interface de la physique, chimie et biologie montre les capacités des NPs à base de platine à améliorer l’éradication par radiation des cellules cancéreuses. / Radiotherapy based on the use of high energy photons (X-rays) is the most common approach in cancer treatment. However, its implementation is limited by the tolerance of healthy tissue. Therefore, it is of major interest the development of new techniques and protocols to improve the selectivity of radiation effects within the tumor. In this perspective, the hadrontherapy (tumor irradiation by protons or carbon ions) is considered as one of the most promising techniques due to the energy deposition of ions in depth which is maximum at the end of the track. However, the use of this modality remains restricted by the lower but significant damage induced to the normal tissue located at the entrance of the ion beam.To improve the performance of radiation therapies, a new strategy based on the combination of metallic nanoparticles (nanomedicine) with ionizing radiations was studied. These treatments have been developed by the group. Indeed, the nanoparticles present a remarkable surface chemistry that allows their functionalization with ligands which make them less recognized by macrophages allowing an important accumulation of these nano-agents selectively into the tumors.The goal of my work was thus to develop platinum based nanoparticles (mono- and bimetallic Pt NPs) to enhance the effect of radiations (photons and carbon ions) into the cells.A novel one-step method of synthesis combining radiolysis and in situ PEGylation has been optimized. This method enabled to obtain stable NPs with a uniform size (metallic core diameter close to 3 nm) and shape. The biological impact of these new Pt NPs was evaluated in two human cancer cell lines.It has been observed that non-toxic Pt NPs have an internalization pathway that strongly depends on the cell line. These are, in all cases, exclusively localized in the cytoplasm. The Pt NPs developed in this work significantly enhanced cancer cell killing, particularly when medical carbon ions are used to irradiate.The molecular mechanisms underlying this effect were investigated through the use of a bio-nanoprobe. These experiments showed that NPs are responsible for the increase of nanometric damage, lesions that can be lethal to cells. This effect is attributed to an electronic activation processes and to the reneutralisation of NPs, which generates a strong perturbation in the surrounding nanometer volume producing highly reactive and toxic free radical clusters.In conclusion, this work at the interface of physics, chemistry and biology shows the potential of platinum NPs to improve the eradication of cancer cells by radiation.
17

Oxygen effect in medical ion beam radiation combined with nanoparticles / Effet de l’oxygène dans l'irradiation par des ions médicaux combinés avec des nanoparticules

Bolsa Ferruz, Marta 18 December 2017 (has links)
Environ 50% des patients recevant un traitement contre le cancer bénéficient de la radiothérapie. La radiothérapie conventionnelle consiste à utiliser des rayons X de haute énergie capables de traverser les tissus et de traiter des tumeurs situées en profondeur de façon non-invasive. Malheureusement, les rayons X ne font pas la distinction entre les tumeurs et les tissus sains, qui peuvent donc être endommagés. Cette non-sélectivité est à l’origine de graves effets secondaires, voire du développement de cancers secondaires. Par conséquent, l’amplification des effets radiatifs au sein de la tumeur par rapport aux tissus environnants représente un défi majeur.L’hadronthérapie (traitement par faisceaux de protons ou d’ions carbone) est considérée comme l’une des techniques les plus prometteuses car, contrairement aux rayons X, la quantité d’énergie déposée atteint son maximum en fin de trajectoire. Lorsque le faisceau est réglé de manière à ce que ce maximum atteigne la tumeur, aucun dommage n’est causé aux tissus situés au-delà. Un autre avantage majeur est que les ions lourds sont plus efficaces pour traiter les tumeurs radiorésistantes. L’utilisation de cette technique est cependant restreinte du fait des dommages – plus faibles mais néanmoins significatifs – causés aux tissus normaux situés sur la trajectoire du faisceau d’ions en amont de la tumeur. Afin d’améliorer les performances de l’hadronthérapie, l’équipe a développé à l’ISMO une nouvelle stratégie combinant l’utilisation de nanoparticules (NPs) métalliques avec l’irradiation par faisceaux d’ions. L’utilisation de NPs a pour but non seulement d’amplifier les effets des rayonnements dans la tumeur mais également d’améliorer l'imagerie médicale à l’aide des mêmes agents (théranostic). Les NPs possèdent une chimie de surface permettant leur fonctionnalisation avec des ligands capable d’améliorer la biocompatibilité, la stabilité ainsi que la circulation sanguine et l’accumulation dans la tumeur. L’équipe a déjà démontré que les petites NPs d’or et de platine (≈ 3 nm) avaient la capacité d’amplifier les effets causés par les faisceaux d’ions carbone médicaux en présence d’oxygène. Cependant, les tumeurs radiorésistantes sont susceptibles de contenir des régions hypoxiques. Il est donc urgent de quantifier et de caractériser l’influence de l’oxygène sur l’effet radio-amplificateur. Le but de ma thèse était d’étudier l’influence de l’oxygène lors d’irradiations par des faisceaux d’ions médicaux en présence de NPs d’or et de platine. Pour cela, deux lignes de cellules cancéreuses humaines radiorésistantes ont été testées: HeLa (col de l’utérus) et BxPC-3 (pancréas). Plusieurs techniques d’irradiation ont été utilisées : des faisceaux d’ions carbone et hélium générés par « passive scattering » et des faisceaux d’ions carbone générés par « pencil beam scanning ». Les principaux résultats de cette étude sont les suivants. En condition oxique (concentration d’O₂ = 20%), une amplification des effets radiatifs a été observée pour les deux types de NPs (à concentration de métal égale). Ce phénomène se réduit à mesure que la concentration d’oxygène diminue mais reste significatif jusqu’à 0.5%. Aucune différence significative n’a été observée entre les deux lignes cellulaires. Il est intéressant de noter que la dépendance à l’oxygène varie en fonction de la technique d’irradiation utilisée. Une tentative d’explication de l’influence de l’oxygène par des processus moléculaires est proposée. Des perspectives de développements ultérieurs sont suggérées. / About 50% of the cancer patients who are treated benefit from radiation therapy. Conventional radiotherapy consists of high energy X-rays traveling through the tissues, so that deeply sited tumors are treated in a non-invasive way. Unfortunately, X-rays are not tumor selective and healthy tissues may be damaged. This lack of selectivity is responsible for severe side effects and/or secondary cancers. Hence, improving the differential of radiation effects between the tumor and surrounding tissues remains a major challenge. Particle therapy (treatment by protons or carbon ion beams) is considered as one of the most promising technique because, by opposition to X-rays, the energy deposition of ions is maximum at the end of their tracks. When the beam is tuned so that the maximum reaches the tumor, there is no damage induced in tissues siting after the tumor. Another important added value is that heavy ions are more efficient to treat radioresistant tumors. The use of this modality is however restricted by the low but significant damage that is induced to normal tissues located at the entrance of the track prior to reaching the tumor. To improve the performance of particle therapy, a new strategy based on the combination of high-Z nanoparticles with ion beam radiation has been developed by the group at ISMO. This approach aims at using nano-agents not only to increase radiation effects in the tumor but also to improve medical imaging with the same agent (theranostic). Nanoparticles present a remarkable surface chemistry, which allows functionalization with ligands able to improve biocompatibility, stability as well as blood circulation and accumulation in tumors. The group already demonstrated the efficiency of small (≈ 3 nm) gold and platinum nanoparticles to amplify the effects of medical carbon ions in normoxic conditions (in the presence of oxygen). However, radioresistant tumors may host hypoxic regions. It is thus urgent to quantify and characterize the influence of oxygen on the radio-enhancement effect. The goal of my thesis was to study the influence of oxygen on medical ion radiation effects in the presence of gold and platinum nanoparticles. This was performed using two radioresistant human cancer cell lines: HeLa (uterine cervix) and BxPC-3 (pancreas). Different radiation modalities were used: carbon and helium ion beams delivered by a passive scattering delivery system and carbon ion beams delivered by a pencil beam scanning system. The major results of this work are the following. In oxic conditions (O₂ concentration = 20%), an enhancement of ion radiation effects was observed for the two nanoparticles (at the same concentration in metal). This effect decreased with the oxygen concentration but remained significant for a concentration of 0.5%. No significant difference was found between the cell lines. Interestingly, the oxygen-dependence varied with the type of radiation. An attempt to explain the effect of oxygen by molecular processes is proposed. Perspectives of further developments are suggested.
18

Étude de l’émission de particules chargées secondaires dans l’optique d’un monitorage faisceau et de la dosimétrie en ligne en hadronthérapie / Study of secondary charged particles emission to monitor in-line dosimetry during hadrontherapy treatment

Henriquet, Pierre 06 July 2011 (has links)
Ce travail est consacré à l'étude de faisabilité d'une imagerie par reconstruction de vertex (IRV) pour le contrôle qualité en temps réel de la thérapie par faisceau d'ions carbone. La détection de vertex d'interactions nucléaires repose sur la détection de particules secondaires : grâce à un dispositif de détection spatiale des fragments chargés (tracker), on peut reconstruire les trajectoires des particules émergeant du patient et les extrapoler jusqu'à leur point d'origine (le vertex)... Dans le cadre de notre étude, la position du vertex est déterminée de deux manières différentes : soit en calculant l'intersection de la trajectoire d'un fragment émergent avec celle de l'ion incident (connue grâce à l'utilisation d'un hodoscope de faisceau placé en amont du patient), soit grâce à l'intersection de la trajectoire de deux fragments émergents détectés en coïncidence. Notre étude de faisabilité de la technique repose sur l'outil de simulation GEANT4. La première partie de l'étude a consisté à valider cet outil grâce à plusieurs expériences réalisées au GANIL (Caen) et au GSI (Darmstadt) avec des ions carbone de différentes énergies dans des cibles d'eau ou de PMMA Par la suite, la comparaison des deux modes de détection des particules secondaires a montré que la technique utilisant l'hodoscope est la plus performante. Enfin, après l'optimisation des principaux paramètres de cette technique, une simulation réaliste montre qu'il est possible de mesurer le parcours des ions avec une précision millimétrique à l'échelle d'une tranche en énergie voire à l'échelle d'un voxel unique / This work is devoted to the feasibility study of interaction vertex imaging (IVI) for real-time quality assurance in hadrontherapy treatments with carbon ion beams. Nuclear interaction vertex detection is based on secondary particle detection: a device allows us to spatially detect charged particles (tracker), thus we can reconstruct the trajectories of particles emerging from the patient and then extrapolate their emission point (vertex). In our study, the vertex position is determined by two ways: either by calculating the intersection of the trajectory of an emerging fragment with the trajectory of the incident ion (measured by means of a beam hodoscope upstream of the patient), or with the intersection of two emerging particles trajectories detected in coincidence. Our feasibility study of this technique relies on the GEANT4 simulation tool. The first part of the study aimed to validate this tool with experiments performed at GANIL (Caen) and GSI (Darmstadt) using carbon ion beams at various energies and in various targets (water or PMMA). Secondly, the comparison of two different technics for secondary particles detection showed that the technique using the hodoscope is the most efficient. Finally, after the parameters optimization of this technique, a realistic simulation shows that it is possible to measure ion paths within millimeter precision during each energy slices. A control of each beam spot may also be possible
19

Etude de conception d'ASICs de lecture et d'étiquetage en temps associés à des photomultiplicateurs pour un hodoscope de faisceau en hadronthérapie

Deng, Shi-Ming 27 November 2012 (has links) (PDF)
Pour développer un hodoscope de faisceau en hadronthérapie, capable de localiser les ions dans le plan transverse et de les étiqueter en temps avec une précision de 1 nc et un taux de comptage de 100 000 000 HZ, nous avons mené des études de conception d'ASICs (Aplication Specific Integrated Circuits) de lecture à associer à des photomultiplicateurs multi-anode. Un front-end ASIC 16 voies en technologieAMS BiCMOS 0,35 µm a été conçu, fabriqué et testé. Il intégre, sur chaque voie, un convoyeur de courant avec deux sorties en étage d'entrée, et deux étages de sortie séparés qui sont respectivement un comparateur en courant et un préamplificateur de charge. Il réalise à la fois la détection d'évènements et la quantification de signal détecté. L'étude de conception a apporté des performances optimisées sur la dynamique d'entrée, la consommation d'énergie, la rapidité, le bruit. Le fonctionnement du circuit de lecture incorporé dans un système de test a aussi été vérifié par une expérimentation en faisceau. D'autre part, nous avons conçu un ASIC d'étiquetage en temps utilisant la technologie AMS CMOS 0,35 µm. Il est à base d'une boucle à verrouillage de délai analogique avec la mise en oeuvre de la méthode de mesure du "temps de vol", et dispose d'un mode d'entrée d'horloge LVDS (Low Voltage Differential Singaling) et d'une sortie de 5 bits en code Gray. Il fonctionne avec une résolution temporelle de 200 ps selon les résultats de tests. Ces études nous ont permis de lancer un nouveau projet de conception : intégrer sur une puce les fonctions électroniques que nous avons réalisées et validées.
20

Design study of a Compton camera for prompts-gamma imaging during ion beam therapy / Conception d'une caméra Compton pour le contrôle en ligne en hadronthérapie

Richard, Marie-Hélène 04 September 2012 (has links)
L'hadronthérapie est une technique innovante de radiothérapie par ions carbone ou protons visant à améliorer les traitements actuels. La précision balistique accrue renforce la nécessité d'un contrôle du dépôt de dose, si possible en temps réel. Une manière de réaliser ce contrôle est de détecter avec une caméra Compton le gamma prompt émis lors des fragmentations nucléaires pendant l'irradiation du patient. Dans un premier temps, la géométrie de deux types de caméra Compton (double diffusion puis simple diffusion) a été optimisée par simulation Monte Carlo. Cette optimisation a été réalisée en étudiant la réponse des caméras à une source ponctuelle de photons avec un spectre en énergie réaliste. La réponse de la caméra optimisée à l'irradiation d'un fantôme d'eau par un faisceau d'ions carbone ou de protons a ensuite été simulée. Ces simulations ont tout d'abord été confrontées à des mesures effectuées avec un prototype de taille réduite. Ces mesures ont ensuite été utilisées pour évaluer les taux de comptage dans les détecteurs attendus en conditions cliniques. Dans la configuration actuelle de la caméra, ces taux sont élevés et les phénomènes d'empilement risquent d'être problématiques. Enfin, il est démontré que le dispositif étudié est sensible à un déplacement du pic de Bragg de plus ou moins 5 mm malgré les problèmes de coïncidences fortuites et malgré le bruit introduit par l'algorithme de reconstruction utilisé. / Ion beam therapy is an innovative radiotherapy technique using mainly carbon ion and proton irradiations. Its aim is to improve the current treatment modalities. Because of the sharpness of the dose distributions, a control of the dose if possible in real time is highly desirable. A possibility is to detect the prompt gamma rays emitted subsequently to the nuclear fragmentations occurring during the treatment of the patient. In a first time two different Compton cameras (double and single scattering) have been optimised by means of Monte Carlo simulations. The response of the camera to a photon point source with a realistic energy spectrum was studied. Then, the response of the camera to the irradiation of a water phantom by a proton beam was simulated. It was first compared with measurement performed with small-size detectors. Then, using the previous measurements, we evaluated the counting rates expected in clinical conditions. In the current set-up of the camera, these counting rates are pretty high. Pile up and random coincidences will be problematic. Finally we demonstrate that the detection system is capable to detect a longitudinal shift in the Bragg peak of +or- 5 mm, even with the current reconstruction algorithm.

Page generated in 0.0551 seconds