• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 221
  • 5
  • 5
  • 5
  • 5
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 227
  • 83
  • 44
  • 41
  • 37
  • 36
  • 29
  • 27
  • 24
  • 23
  • 22
  • 21
  • 20
  • 17
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Aplicação de eletrodos compósitos à base de grafite-poliuretana modificados com polímeros com impressão molecular, na determinação de ácido fólico e diclofenaco / Application of graphite-polyurethane composite electrodes modified with molecularly imprinted polymers in the determination of folic acid and diclofenac

Pereira, Abigail Vasconcelos 14 August 2015 (has links)
Neste trabalho foram preparados eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (EGPU-MIP) visando a determinação de ácido fólico (FA) e forma ácida do diclofenaco (DCF), os quais foram usados como moléculas molde. O objetivo principal era avaliar o desempenho dos MIPs em relação à seletividade e sensibilidade, além da inovação em relação ao uso dos compósitos como material de eletrodo, relativamente a esses analitos. No caso do FA, os MIP foram preparados com essa molécula, relativamente grande e contendo vários grupos funcionais, para avaliar o efeito dessas características no desempenho do sensor. Inicialmente foram feitos estudos exploratórios usando voltametria cíclica (CV), nos quais o FA apresentou pico irreversível de oxidação em +0,80 V (vs. SCE) e picos reversíveis de redução em -0,40 e -0,65 V (vs. SCE), com respectivos processos de oxidação em -0,33 e -0,49 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco usando voltametria de pulso diferencial (DPV), após otimizar parâmetros tais como composição de MIP no sensor de (2,5%, m/m), amplitude de pulso (a = 50 mV), velocidade de varredura (ν = 10 mV s-1) e meio eletrolítico (tampão acetato, pH = 4,5). Nesse procedimento, determinou-se uma mesma região linear de resposta entre 0,6 e 2,0 µmol L-1 para os dois picos de redução em -0,52 e -0,58 V (vs. SCE), com limites de detecção (LOD) de 0,17 e de 0,03 &micromol L-1, respectivamente. O pico em -0,58 V mostrou-se mais sensível e foi escolhido para determinar o FA nas formulações farmacêuticas Folacin&reg, Afopic&reg e Folifolim&reg, com resultados concordantes com o método oficial baseado na Cromatografia líquida de alta eficiência (HPLC), em 95% de confiança, segundo o teste t-Student. O MIP-FA mostrou-se mais seletivo que o polímero sem impressão molecular (NIP-DCF) frente às interferências do metotrexato (MTX), porem o ácido ascórbico (AA), ácido úrico (UA) e dopamina (DA) mostraram interferências, em relação aos grupos funcionais presentes nessas espécies, com forte influência da rigidez estrutural e da mobilidade rotacional de tais grupos. Outro MIP foi sintetizado com impressão para DCF. A voltametria cíclica mostrou que o DCF apresenta pico irreversível de oxidação em + 0,83 V (vs. SCE), na primeira varredura e picos reversíveis de redução em +0,40 e +0,65 V (vs. SCE), a partir da segunda varredura, com respectivos processos de oxidação em +0,27 e +0,58 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco em formulações comerciais, usando DPAdASV, após otimização dos parâmetros tais como composição de MIP no sensor (2,5%, m/m), tempo de acumulação (300 s) e potencial de pré-concentração (+0,2 V), a = 50 mV, ν = 10 mV s-1 em ácido perclórico pH condicional (pHcond) = 1,6, com uma região linear entre 0,010 e 0,20 nmol L-1 e LOD de 0,99 nmol L-1 para o pico anódico em +0,8 V (vs. SCE). O DCF foi determinado nas formulações farmacêuticas Biofenac&reg, Medley&reg e Voltaren&reg e em urina sintética. O MIP-DCF se mostrou relativamente seletivo ao sinal do DCF, mesmo na presença dos interferentes como ácido meclofenâmico (AMCFN) e ácido mefenâmico (AMFN), os quais apresentam grande semelhança estrutural e funcional em relação ao analito. Deve-se tomar cuidado ao estender o intervalo de potencial operacional para o GPU, neste meio de ácido perclórico, para evitar ativação de grupos funcionais do grafite e/ou da PU. / In this work methacrylate molecularly imprinted polymers (MIP) were prepared using folic acid (FA) as well as diclofenac (DCF) templates. These MIPs were used in the modification of graphite-polyurethane (GPU) composites in order to evaluate the performance of the resulting electrodes in the determination of the templates in pharmaceutical formulations and to estimate the sensitivity and selectivity of the resulting devices joined to the innovation of using the composites in such development regarding these analytes. In the case of FA, MIPs were prepared with this relatively large and containing multiple functional groups, to evaluate the effect of such characteristics in the performance of the sensor. First of all exploratory experiments were performed using cyclic votammetry (CV) in which the FA presented an irreversible oxidation peak at + 0.80 V (vs. SCE) and reversible reductions peaks at -0.40 and -0.65 V (vs. SCE) with respective oxidation at -0.33 and -0.49 V (vs. SCE). An analytical procedure was developed based on differential pulse voltammetry (DPV), after optimizing parameters such as MIP composition in the sensor (2.5%, m/m), pulse amplitude (a = 50 mV), scan rate (ν = 10 mV s-1) and supporting electrolyte (acetate, pH = 4.5). In such procedure was obtained a linear dynamic range from 0.6 to 2.0 &micromol L-1 for both DPV reduction peaks at -0.52 and -0.58 V (vs. SCE), with limit of detection (LOD) of 0.17 and 0.03 &micromol L-1, respectively. As the second on was more sensitive it was chosen for the determination of FA in the commercial pharmaceutical formulation Folacin&reg, Afopic&reg and Folifolim&reg,with results that agreed with those from the official HPLC procedure within 95% confidence level according to the t-Student test. The MIP-FA was more selective than the non-imprinted polymer (NIP-DCF) in relation to the interference of metotrexate (MTX), however ascorbic acid (AA), uric acid (UA) and dopamine (DA) revealed significant interferences regarding the functional groups present in these species, with strong influence from the structural rigidity of the molecule that plays an important role in the rotational mobility of these groups. Another MIP was synthesized with DCF as a template. Cyclic voltammetry demonstrated that the DCF presented a single irreversible oxidation peak at + 0.83 V (vs. SCE) in the first scan, and two reversible reduction peaks at +0.40 and +0.65 V (vs. SCE) with respective oxidation at +0.27 and +0.58 V (vs. SCE), from the second scan. A DPAdASV procedure was also developed for the determination of DCF in commercial formulations after optimizing some experimental parameters such as MIP composition in the sensor (2.5%, m/m), accumulation time (300 s) and potential (+0.2 V), a = 50 mV, v = 10 mV s-1 and supporting electrolyte (perchloric acid pHcond = 1.6). A linear dynamic range from 0.010 to 0.20 nmol L-1 and a LOD of 0.99 nmol L-1 were observed for the anodic peak at +0.8 V (vs. SCE). Then the DCF was determined in the commercial formulations Biofenac&reg, Medley&reg and Voltaren&reg and also in synthetic urine samples. The MIP-DCF sensor showed to be selective regarding the DCF signal even in the presence of meclophenamic acid (AMCFN) and mefenamic acid (AMFN), which present structural and functional similarity when compared with the analyte. Care must be taken when using the GPU in extreme potential windows in the perchloric acid medium, to avoid activation of functional groups in the polymer.
182

Fabricação e caracterização de transistores orgânicos por impressão de jato de tinta / Fabrication and characterization of organic transistors by inkjet printing

Stefanelo, Josiani Cristina 02 July 2014 (has links)
A tecnologia dos semicondutores inorgânicos tem dominado a indústria eletrônica por muitos anos. No entanto, com a descoberta dos polímeros condutores um esforço considerável tem sido dedicado ao estudo e às aplicações tecnológicas desses materiais em dispositivos eletrônicos, dando início a um novo ramo da eletrônica: a Eletrônica Orgânica (EO). Uma das grandes vantagens da EO reside nos métodos de processamento. Os materiais orgânicos são facilmente processados em solução, portanto permite o uso de diversas técnicas de deposição, como por exemplo, as técnicas de impressão. Dentre as técnicas de impressão, a jato de tinta é a que mostra ser mais adequada à impressão de circuitos. Ela permite depositar volumes de soluções (ou suspensões) da ordem de picolitros em cada gota mantendo padrões bem definidos. Além disso, elimina o uso de máscaras, ocasionando diminuição nos custos e desperdício de material e, por ser um método de deposição tipo não-contato, minimiza possíveis contaminações. Esta tese dedicou-se, dentro desse contexto, ao domínio da técnica de jato de tinta para a confecção de transistores de efeito de campo orgânico (OFETs) tipo p e tipo n, e com aplicação em um inversor lógico unipolar. Os OFETs impressos usaram a arquitetura top gate/bottom contact (TG/BC. Os filmes semicondutores foram formados por várias linhas impressas sobre a região dos eletrodos fonte e dreno. Para os OFETs tipo p foi utilizado o semicondutor Poli(3-hexiltiofeno) régio-regular (rr-P3HT). Foram fabricados OFETs tipo p com a impressão de linhas utilizando os quatro diferentes padrões de deposição da impressora Autodrop. OFETs tipo p com mobilidade em torno de 3x10-3 cm2/V.s e razões Ion/Ioff da ordem de 103 foram obtidos utilizando um padrão de deposição paralelo e outro perpendicular a fonte e dreno. Para os OFETs tipo n o semicondutor usado foi o Poli{[N,N\'-bis(2-octildodecil)-naftaleno-1,4,5,8-bis(dicarboximida)-2,6-diil]-alt-5,5\'-(2,2\'-bitiofeno)]} (P(NDI2OD-T2)). Dentre os OFETs tipo n impressos os melhores apresentaram mobilidades em torno de 10-2 cm2/V.s e razões Ion/Ioff de aproximadamente 5x102. Ambos os OFETs impressos foram aplicados em inversores lógicos digitais unipolares com ganhos maiores que 1. / The technology of inorganic semiconductors has dominated the industry of electronics for many years. However, since the discovery of conductive polymers considerable effort has been devoted to studies and technological applications of these materials in electronic devices, starting a new branch of electronics: Organic Electronics (OE). One of the great advantages of OE lies in the processing methods. The organic materials are easily handled in solution, thus allows the use of various deposition techniques, as for example the printing techniques. Among the techniques of printing, inkjet is showing to be more suitable for printing circuits. It allows you to deposit solutions (or suspensions) volumes on the order of picoliters in each drop, performing well-defined patterns. Furthermore, it eliminates the use of masks, resulting in reduced costs and material waste. This thesis is dedicated to the field of inkjet technique, specifically for the fabrication of organic field-effect transistors (OFETs), p-type and n-type, and application in a unipolar logic inverter. Printed OFETs used architecture top gate/bottom contact (TG/BC). The semiconductor films were formed by several printed lines on the region of the source and drain electrodes. For p-type OFETs we used poly (3-hexylthiophene ) regio-regular (rr-P3HT) as semiconducting material. The p-type OFETs were fabricated using the four different patterns of deposition of the printer Autodrop. These OFETs showed mobility around 3x10-3 cm2/V.s and Ion/Ioff ratio of the order of 103 for the deposition pattern parallel and perpendicular to source and drain. For the n-type OFETs the semiconductor used was Poly{[N,N\'-bis(2-octyldodecyl)-naphthalene-1,4,5,8-bis(dicarboximide)-2,6-diyl]-alt-5,5\'-(2,2\'-bithiophene)]} (P(NDI2OD-T2)). Among the printed n-type OFETs the best showed mobility around of 10-2 cm2/V.s and Ion/Ioff ratio of the order of 5x102. Both printed OFETs were applied in unipolar digital logic inverters, with gains greater than 1.
183

Aplicação de eletrodos compósitos à base de grafite-poliuretana modificados com polímeros com impressão molecular, na determinação de ácido fólico e diclofenaco / Application of graphite-polyurethane composite electrodes modified with molecularly imprinted polymers in the determination of folic acid and diclofenac

Abigail Vasconcelos Pereira 14 August 2015 (has links)
Neste trabalho foram preparados eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (EGPU-MIP) visando a determinação de ácido fólico (FA) e forma ácida do diclofenaco (DCF), os quais foram usados como moléculas molde. O objetivo principal era avaliar o desempenho dos MIPs em relação à seletividade e sensibilidade, além da inovação em relação ao uso dos compósitos como material de eletrodo, relativamente a esses analitos. No caso do FA, os MIP foram preparados com essa molécula, relativamente grande e contendo vários grupos funcionais, para avaliar o efeito dessas características no desempenho do sensor. Inicialmente foram feitos estudos exploratórios usando voltametria cíclica (CV), nos quais o FA apresentou pico irreversível de oxidação em +0,80 V (vs. SCE) e picos reversíveis de redução em -0,40 e -0,65 V (vs. SCE), com respectivos processos de oxidação em -0,33 e -0,49 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco usando voltametria de pulso diferencial (DPV), após otimizar parâmetros tais como composição de MIP no sensor de (2,5%, m/m), amplitude de pulso (a = 50 mV), velocidade de varredura (ν = 10 mV s-1) e meio eletrolítico (tampão acetato, pH = 4,5). Nesse procedimento, determinou-se uma mesma região linear de resposta entre 0,6 e 2,0 µmol L-1 para os dois picos de redução em -0,52 e -0,58 V (vs. SCE), com limites de detecção (LOD) de 0,17 e de 0,03 &micromol L-1, respectivamente. O pico em -0,58 V mostrou-se mais sensível e foi escolhido para determinar o FA nas formulações farmacêuticas Folacin&reg, Afopic&reg e Folifolim&reg, com resultados concordantes com o método oficial baseado na Cromatografia líquida de alta eficiência (HPLC), em 95% de confiança, segundo o teste t-Student. O MIP-FA mostrou-se mais seletivo que o polímero sem impressão molecular (NIP-DCF) frente às interferências do metotrexato (MTX), porem o ácido ascórbico (AA), ácido úrico (UA) e dopamina (DA) mostraram interferências, em relação aos grupos funcionais presentes nessas espécies, com forte influência da rigidez estrutural e da mobilidade rotacional de tais grupos. Outro MIP foi sintetizado com impressão para DCF. A voltametria cíclica mostrou que o DCF apresenta pico irreversível de oxidação em + 0,83 V (vs. SCE), na primeira varredura e picos reversíveis de redução em +0,40 e +0,65 V (vs. SCE), a partir da segunda varredura, com respectivos processos de oxidação em +0,27 e +0,58 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco em formulações comerciais, usando DPAdASV, após otimização dos parâmetros tais como composição de MIP no sensor (2,5%, m/m), tempo de acumulação (300 s) e potencial de pré-concentração (+0,2 V), a = 50 mV, ν = 10 mV s-1 em ácido perclórico pH condicional (pHcond) = 1,6, com uma região linear entre 0,010 e 0,20 nmol L-1 e LOD de 0,99 nmol L-1 para o pico anódico em +0,8 V (vs. SCE). O DCF foi determinado nas formulações farmacêuticas Biofenac&reg, Medley&reg e Voltaren&reg e em urina sintética. O MIP-DCF se mostrou relativamente seletivo ao sinal do DCF, mesmo na presença dos interferentes como ácido meclofenâmico (AMCFN) e ácido mefenâmico (AMFN), os quais apresentam grande semelhança estrutural e funcional em relação ao analito. Deve-se tomar cuidado ao estender o intervalo de potencial operacional para o GPU, neste meio de ácido perclórico, para evitar ativação de grupos funcionais do grafite e/ou da PU. / In this work methacrylate molecularly imprinted polymers (MIP) were prepared using folic acid (FA) as well as diclofenac (DCF) templates. These MIPs were used in the modification of graphite-polyurethane (GPU) composites in order to evaluate the performance of the resulting electrodes in the determination of the templates in pharmaceutical formulations and to estimate the sensitivity and selectivity of the resulting devices joined to the innovation of using the composites in such development regarding these analytes. In the case of FA, MIPs were prepared with this relatively large and containing multiple functional groups, to evaluate the effect of such characteristics in the performance of the sensor. First of all exploratory experiments were performed using cyclic votammetry (CV) in which the FA presented an irreversible oxidation peak at + 0.80 V (vs. SCE) and reversible reductions peaks at -0.40 and -0.65 V (vs. SCE) with respective oxidation at -0.33 and -0.49 V (vs. SCE). An analytical procedure was developed based on differential pulse voltammetry (DPV), after optimizing parameters such as MIP composition in the sensor (2.5%, m/m), pulse amplitude (a = 50 mV), scan rate (ν = 10 mV s-1) and supporting electrolyte (acetate, pH = 4.5). In such procedure was obtained a linear dynamic range from 0.6 to 2.0 &micromol L-1 for both DPV reduction peaks at -0.52 and -0.58 V (vs. SCE), with limit of detection (LOD) of 0.17 and 0.03 &micromol L-1, respectively. As the second on was more sensitive it was chosen for the determination of FA in the commercial pharmaceutical formulation Folacin&reg, Afopic&reg and Folifolim&reg,with results that agreed with those from the official HPLC procedure within 95% confidence level according to the t-Student test. The MIP-FA was more selective than the non-imprinted polymer (NIP-DCF) in relation to the interference of metotrexate (MTX), however ascorbic acid (AA), uric acid (UA) and dopamine (DA) revealed significant interferences regarding the functional groups present in these species, with strong influence from the structural rigidity of the molecule that plays an important role in the rotational mobility of these groups. Another MIP was synthesized with DCF as a template. Cyclic voltammetry demonstrated that the DCF presented a single irreversible oxidation peak at + 0.83 V (vs. SCE) in the first scan, and two reversible reduction peaks at +0.40 and +0.65 V (vs. SCE) with respective oxidation at +0.27 and +0.58 V (vs. SCE), from the second scan. A DPAdASV procedure was also developed for the determination of DCF in commercial formulations after optimizing some experimental parameters such as MIP composition in the sensor (2.5%, m/m), accumulation time (300 s) and potential (+0.2 V), a = 50 mV, v = 10 mV s-1 and supporting electrolyte (perchloric acid pHcond = 1.6). A linear dynamic range from 0.010 to 0.20 nmol L-1 and a LOD of 0.99 nmol L-1 were observed for the anodic peak at +0.8 V (vs. SCE). Then the DCF was determined in the commercial formulations Biofenac&reg, Medley&reg and Voltaren&reg and also in synthetic urine samples. The MIP-DCF sensor showed to be selective regarding the DCF signal even in the presence of meclophenamic acid (AMCFN) and mefenamic acid (AMFN), which present structural and functional similarity when compared with the analyte. Care must be taken when using the GPU in extreme potential windows in the perchloric acid medium, to avoid activation of functional groups in the polymer.
184

Elaboração de próteses auriculares individualizadas por meio de manufatura apoiada por computador. / Custom auricular prostheses design by computer-aided manufacturing.

Emerson Galves Moretto 22 November 2016 (has links)
Próteses auriculares tem o objetivo de proporcionar uma maior confiança a pacientes com perdas parciais ou totais da orelha. A aparência realista de uma prótese é fator fundamental para a recuperação psicossocial dos pacientes, pois auxilia na dissimulação da perda. O procedimento convencional de elaboração de próteses auriculares envolve o trabalho de um especialista que utiliza processos manuais para recriar a forma singular de uma orelha. Este é um processo lento, complexo e naturalmente pode ocasionar imperfeições. Este estudo apresenta um procedimento que, a partir de exames de imagem, utiliza técnicas computacionais de reconstrução, espelhamento e inversão de modelos tridimensionais para manufatura aditiva (impressão 3D) de moldes. Os resultados mostram que a prótese elaborada utilizando o processo exibe alto grau de realismo, apresentando 97,8% de similaridade dimensional comparada com a orelha sã do paciente. / Auricular prostheses are intended to provide confidence to patients with partial or total loss of the ear. The realistic appearance of a prosthesis is a key factor for the psychosocial recovery helping in dissimulation of loss. The standard procedure of auricular prosthesis design involves the work of an expert using manual processes to recreate the complex shape of the ear. This slow and complex process can easily lead to imperfections. This study presents a procedure that starting from an image exam uses computational techniques of reconstruction, mirroring and inversion of three-dimensional models for additive manufacturing (3D printing) of molds. The results show that the designed prosthesis using the process has a high level of realism, with 97.8% of similarity compared to the healthy ear of the patient.
185

Projeto conceitual de órtese estabilizadora para o ombro / Concept and development of shoulder stabilizer orthose

Assad, Danielle Aline Barata 26 March 2018 (has links)
A subluxação do ombro é a complicação musculoesquelética mais comum das afecções do Sistema Nervoso Central e Periférico, que leva a diminuição do movimento, da função e aumento de dor. Um dos recursos auxiliares utilizados é a órtese que visa corrigir a deformidade, diminuir a dor e proporcionar a função. Este trabalho objetiva projetar e desenvolver o conceito de uma órtese personalizada estabilizadora de ombro. A metodologia de desenvolvimento de projeto de produto esta dividida em três fases: informacional, conceitual e projeto preliminar. Na fase informacional foi realizada pesquisa bibliográfica, de patentes e de mercado e foram entrevistados 30 prováveis usuários; coletados os dados antropométricos, força muscular manual e goniometria. Na fase conceitual, baseado na fase informacional e a partir da Metodologia TRIZ (Teoria da Resolução de Problemas Inventivos) foi proposto um desenho original de órtese híbrida, personalizada e manufaturada em tridimensional, usando estruturas rígidas e faixas de tração, que estabilizem o ombro, diminua a dor e permita a função. A fase do projeto preliminar foi composta por escaneamento tridimensional e uso de softwares que transformam uma imagem digitalizada em formato STL®. Foram realizadas sucessivas evoluções do projeto com geração de desenhos e peças prototipadas que foi avaliada por um usuário. Na fase informacional, a pesquisa de patentes e de mercado mostrou que há uma predominância dos modelos de órtese estabilizadora de ombro com material flexível onde o principal meio de tração é dado por faixas na diagonal e transversal ao tronco, tendendo a posicionar o ombro em rotação interna. Enquanto os usuários relataram expectativa de uma órtese que corrija o posicionamento, tenha melhor conforto térmico e tátil, menos cheiro e de fácil limpeza. O conceito desenvolvido foi: órtese personalizada, fácil de higienizar e de por/tirar, resistente, articulada, leve, em plástico ABS (acrilonitrila, butadieno e estireno) impressão tridimensional, com veste nos dois braços, com faixas de tração rígidas fixadas à cintura, visando à correção da subluxação do ombro com conforto, menor dor além de permitir função. O teste com usuário corroborou com o conceito, pois o protótipo preliminar apresentou bom acoplamento ao tronco, tração satisfatória e possibilidade de realizar um maior número de atividades diárias com menos dor e sensação de cansaço. / The shoulder subluxation is the most common musculoskeletal complication of Central and Peripheral Nervous System disorders, which leads to a decrease in movement, function and increase in pain. One of the resources used to help with this issue is the orthosis that aims to correct the deformity, decrease the pain and provide function. This work aims to design and develop the concept of a personalized shoulder stabilizing orthosis. The methodology used on the product design is divided into three phases: informational, conceptual and preliminary design. In the informational phase, bibliographic, patent and market research were carried out and 30 potential users were interviewed; anthropometric data, manual muscle strength and goniometry were collected. In the conceptual phase, based on the informational data and using TRIZ Methodology (Theory of Inventive Problem Solving), an original concept design of a hybrid orthosis, personalized and manufactured three-dimensional, using rigid structures and traction bands, was proposed to stabilize the shoulder, reduce pain and allow function. The preliminary design phase consisted of tridimensional scanning and the use of software that transformed a scanned image into STL®. Successive evaluations of the project were carried out with generation of designs and prototyped parts - which the user has evaluated. During the informational phase, the patent and market research demonstrated a predominance of the stabilizing orthosis models using flexible material where the main form of traction was given by diagonal and transverse bands to the trunk, tending to position the shoulder in internal rotation. Users have reported the expectation that this orthosis could correct the shoulder positioning and that it has a better thermal and tactile comfort, less smell and easier to clean. The concept developed was: a personalized orthosis, easy to sanitize and to put on/take off, resistant, articulated, lightweight, in ABS (Acrylonitrile butadiene styrene), three-dimensional printing, with a vest in both arms, rigid traction bands fixed to the waist, aiming to correct the shoulder subluxation with comfort, less pain while allowing function. The user test corroborated with the concept, as the preliminary prototype presented good trunk coupling, satisfactory traction and the possibility to perform a greater number of daily activities with less pain and less fatigue caused by limb weight.
186

Determinação de tetraciclina utilizando eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular / Determination of tetracycline using graphite-polyuretane composites electrodes modified with methacrylate molecularly imprinted polymers

Clarindo, José Eduardo dos Santos 27 September 2017 (has links)
Neste trabalho propôs-se desenvolver eletrodos compósitos à base de grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (MIP-TC), visando a determinação do antibiótico tetraciclina em formulações farmacêuticas e urina sintética. O trabalho também visou contribuir no desenvolvimento de um sensor com melhor desempenho no que diz respeito à sensibilidade e seletividade do eletrodo compósito modificado, na quantificação do analito/molécula molde em matrizes complexas. Técnicas eletroanalíticas, tais como voltametria cíclica (CV) e voltametria de pulso diferencial (DPV) foram utilizadas para avaliar a resposta em termos de sensibilidade e seletividade do eletrodo compósito na detecção da tetraciclina (TC), proposto neste trabalho. A otimização dos parâmetros, tais como composição do MIP (5,0 %, m/m), amplitude de pulso (50 mV), velocidade de varredura (10 mV s-1), tempo (300 s) e potencial de acumulação [(+ 0,7 V (vs. SCE)] e faixa granulométrica do MIP (150 a 250 μm), usando voltametria de redissolução anódica por pulso diferencial foi realizada para maximizar a determinação da tetraciclina em tampão fosfato 0,10 mol L -1 (pH 2,5), permitindo obter limites de detecção de 0,555 μmol L-1, 2,70 μmol L-1 e 4,71 μmol L-1, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, sem necessidade de renovação da superfície do eletrodo entre as sucessivas medidas. Regiões lineares entre 4,0 e 60,0 μmol L-1, 8,0 e 60,0 μmol L-1 e 20,0 e 100,0 μmol L-1/sup> foram observadas, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, para o pico anódico em + 0,9 V (vs. SCE). Os EGPU também foram testados quanto à seletividade frente à possíveis interferentes, sendo utilizados clortetraciclina (CTC) e oxitetraciclina (OTC) para os testes de interferência. Em todos os casos, a interferência do EGPU-MIP-TC foi menor do que a obtida com o EGPU-NIP, confirmando que o EGPU-MIP-TC foi mais efetivo na capacidade de reconhecer seletivamente o analito na presença dos interferentes CTC e OTC. Após as etapas de síntese dos MIP/NIP e confecção dos eletrodos, otimização dos parâmetros, avaliações e testes de sensibilidade e seletividade dos EGPU, os eletrodos foram submetidos à aplicação em duas amostras de medicamentos comerciais, TetraMed® 500 mg e genérico de cloridrato de tetraciclina 500 mg e uma amostra sintética de urina. Os resultados foram comparados ao método oficial por HPLC, apresentando 95 % de confiança, de acordo com o teste t-Student. / In this work, graphite-polyurethane composites electrodes were modified with methacrylate molecularly imprinted polymers (MIP-TC) in order to evaluate the electrodes in the determination of tetracycline (TC) antibiotic in pharmaceutical formulations as well as in biological fluid. The work aimed to contribute in development of a sensor with better performance about the sensitivity and selectivity of the composites electrodes modified in quantification of this analyte. Electroanalytical techniques such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to evaluate the selectivity and sensitivity of the composite electrodes in the detection of tetracycline. The parameters optimization, such as MIP composition (5.0 %, m/m), pulse amplitude (50 mV), scan rate (10 mV s-1), accumulation time (300 s), accumulation potential [+ 0.7 V (vs. SCE)], and MIP granulometry (150 to 250 μm), using differential pulse anodic stripping voltammetry was done to maximize the determination of tetracycline in phosphate buffer 0.1 mol·L-1 pH 2.5 resulting in LOD of 0.555 μmol L-1, 2.70 μmol L-1 and 4.71 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP, without the need for surface renovation between the measures. A linear dynamic range from 4.0 to 60.0 μmol L-1, 8.0 to 60.0 μmol L-1 and 20.0 to 100.0 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP was observed for the anodic peak at + 0.9 V (vs. SCE). The EGPU were also tested regarding the selectivity compared to possible interferents, such as chlortetracycline (CTC) and oxytetracycline (OTC) for the interference study. In all cases, the interference of EGPU-MIP-TC was lower than the one that was got with EGPU-NIP, confirming that the EGPU-MIP-TC was more selective than the non-imprinted polymer in the capacity of recognizing, selectively, the analyte in presence of CTC and OTC interferents. After the steps of synthesis of MIP/NIP and electrodes confection, parameters optimization, evaluation and EGPU sensitivity and selectivity studies, the electrodes were submitted to the application in two commercial drugs containing 500 mg of tetracycline cloridrate, TetraMed® and generic; and a synthetic urine sample. The results were compared to the official method by HPLC, presenting 95 % confidence according to the t-Student test.
187

Desenvolvimento de uma técnica de desenho digital e impressão em 3D de placas oclusais e sua aplicabilidade no tratamento de pacientes com disfunção temporomandibular / Development of a technique of digital design and 3D printing of occlusal splints and its applicability in the treatment of patients with temporomandibular disorders

Vasques, Mayra Torres 11 December 2018 (has links)
O uso de novas tecnologias na odontologia, como a técnica CAD/CAM, promete ser uma opção relevante no que diz respeito à confecção das placas oclusais, empregadas no tratamento de disfunções temporomandibulares. O objetivo desta pesquisa foi desenvolver uma técnica para desenho e confecção de placas oclusais pelo método CAD/CAM, em impressora 3D, e verificar seus resultados clínicos no tratamento de pacientes com disfunções temporomandibulares. Para o desenho das placas foi desenvolvida uma metodologia de desenho digital (CAD), utilizando o software Meshmixer® (Autodesk, USA), e de registro das relações maxilo-mandibulares. A partir dessa metodologia iniciou-se um estudo clínico randomizado comparativo entre as placas CAD/CAM produzidas em impressora 3D e placas produzidas convencionalmente em laboratório. O estudo foi realizado em duas etapas, 18 pacientes foram avaliados de acordo com os critérios de inclusão e exclusão. Na Etapa 1 (n=18) foram realizados testes técnicos comparativos das duas placas em relação à dor, por meio da Escala Visual Analógica; atividade muscular; ajuste interno; báscula; conforto; tempo de instalação; pontos de contato oclusal. Todos os pacientes da amostra utilizaram os dois tipos de placas. Na Etapa 2, estes pacientes foram divididos randomicamente em dois grupos para o estudo clínico randomizado (estudo cego): Grupo IMP (n=9) (placas impressas) e grupo LAB (n=9) (placas convencionais laboratoriais). Os grupos foram avaliados após 1 mês de uso, por meio dos Questionários, RDC/TMD, SF-36, escala visual de dor EVA, e pelos pontos de contato oclusais. Os dados foram avaliados estatisticamente usando os testes de Wilcoxon, de Mann-Whitney, e de Kruskal-Wallis nas análises quantitativas; os testes Qui-Quadrado e Exato de Fisher, nas variáveis categóricas. Os resultados mostraram que houve diferenças significativas (P-valor<0.05) nas avaliações para conforto, ajuste interno e tempo de confecção das placas, a favor das placas impressas. Nas demais avaliações, os grupos foram equivalentes (não- significantes). Concluiu-se que foi possível desenvolver uma técnica para desenho e confecção de placas oclusais pelo método CAD/CAM, em impressora 3D, e que o desempenho clínico foi equivalente entre as placas convencionais e impressas, sendo que estas se mostraram superiores quanto ao conforto e quanto à adaptação da superfície interna da placa, mostrando ser este um método possível e viável economicamente. / The use of new technologies in dentistry, as the CAD/CAM technique, promises to be a relevant option concerning the manufacture of occlusal splints for temporomandibular disorders treatment. The aim of this research was to develop a technique for design and manufacture occlusal splints using the CAD/CAM method and 3D printer and verify the clinical results in the treatment of temporomandibular disorders patients. It was developed a technique for occlusal splint design a using the software Meshmixer® (Autodesk, USA) and a technique to register the jaws relationship. From this method, it was started a Randomized Clinical Trial (RCT) to compare splints made through the CAD/CAM technique and others made conventionally in a dental lab. The study was performed in two steps, 18 patients were selected based on the inclusion/exclusion criteria. In Step 1 (n=18) patients were comparatively evaluated, using both splints, in relation to pain, using the visual analog scale; internal adjustment of the splint; patients comfort; time spent to deliver the appliance and occlusal contacts pattern. In Step 2, these patients were allocated in two groups (n=9 each group) randomly to the RCT be performed (blind study): Group IMP - printed splints and Group LAB (conventional lab splints). Both groups were assessed after 1 month using the splint using RDC/TMD and SF-36 questionnaires, the visual analog scale for pain, and occlusal contacts pattern. The data were statistically evaluated using Wilcoxon, Mann-Whitney, and Kruskal-Wallis test for qualitative analyses and Qui-square and Fisher´s exact tests for categorical variables. The results showed significant statistical differences (p-value<0.05) in favor of printed occlusal splints, related to patients\' comfort, internal adjustment, and time spent to deliver the appliance. All other assessments were equivalents (not significant). It was concluded that it was possible to develop a technique to design and manufacture occlusal splints using CAD/CAM and 3D printer, and furthermore the clinical performance was equivalent comparing conventional and printed occlusal splints, being the printed splints superior to conventional splints in relation to comfort and internal adjustment, proving this is a possible and economically viable method.
188

Biomateriais multifuncionais aplicados em reparo ósseo na odontologia /

Barud, Hélida Gomes de Oliveira. January 2017 (has links)
Orientador: Osmir Batista de Oliveira Junior / Abstract: A regeneração óssea caracteriza-se por ser um processo fisiológico complexo que envolve a participação coordenada entre angiogênese e osteogênese. Envolve um processo de múltiplas etapas que inclui migração, proliferação e diferenciação de vários tipos de células, como células endoteliais, fibroblastos, osteoblastos e osteoclastos. Sabe-se que os biomateriais sintéticos têm demonstrado ser uma excelente alternativa ao reparo ósseo. Assim, o objetivo deste estudo foi avaliar o efeito do Biosilicato de sódio (BS) e dos compósitos 3D de 30% de hidroxiapatita e ácido poliláctico (3D 30% HA / PLA) e 30% hidroxiapatita e ácido poli (ácido láctico-co-glicólico) (30% HA / PLGA), e em defeitos críticos na calvária de ratos. Cento e vinte ratos machos de 90 dias com 350g de massa corporal em média foram aleatoriamente divididos em grupos de acordo com materiais de enxerto e tempo de análise, apresentando 6 animais em cada um. Os defeitos de tamanho crítico foram criados empregando-se uma trefina de 8 mm de diâmetro interno e preenchidos com os materiais mencionados ou apenas o coágulo sanguíneo como controle. Após 14 (T1), 30 (T2), 60 (T3), 90 (T4) e 120 dias (T5) dias do procedimento cirúrgico, a regeneração óssea foi avaliada por radiografia, microtomografia computadorizada (μ-CT) e histologia. A avaliação macroscópica mostrou biocompatibilidade em torno da área de interesse entre os biomateriais e ossos adjacentes. As imagens de μ-CT e de raios-x revelaram uma considerável formação ... (Complete abstract click electronic access below) / Resumo: The process of bone regeneration requires a coordinated coupling between osteogenesis and angiogenesis involveing a multistep process that includes migration, proliferation, and differentiation of several types of cells such as endothelial, fibroblasts, osteoblasts and osteoclasts. It is known that synthetic biomaterials have been proven to be an excellent alternative to bone repair. Thus, the aim of this study is to evaluate the effect of calcium and sodium Biosilicate (BS), a 3D scaffold of hydroxyapatite and polylactic acid (30% HA / PLA) and a hydroxyapatite and poly (lactic-co-glycolic acid) (30% HA / PLGA) composites in critical-sized calvarial defects. One hundred and twenty 90 days old male rats with 350g of body mass on average were randomly divided into groups (n = 6) according to graft materials and analysis time. Critical-size defects were created by means of a 8 mm inner diameter trephine bur and were filled with a 3D 30% HA/PLGA scaffold, 30% HA/PLA, BS or blood clot as control. After 15 (T1), 30 (T2), 60 (T3), 90 (T4) and 120 (T5) days of the cirurgical procedure, bone regeneration was evaluated by histology, x-ray and micro-computed tomography (µ-CT). Macroscopic evaluation showed no significant inflamation around the interest area. µ-CT results indicates that 30% HA/PLA and 3D 30% HA/PLGA composites were not fully degraded and images revealed considerable bone formation in 90 days and 120 days in relation to these materials. On the other hand, BS presented a ... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
189

Modelos de células interativos: facilitadores na compreensão das estruturas celulares e no processo de inclusão de indivíduos com necessidades educacionais especiais visuais. / Interactive models of cells: facilitating the understanding of cell structures and processes for the inclusion of individuals with special visual needs.

Dümpel, Renata Guimarães January 2011 (has links)
Submitted by Isac Macêdo (isac@ioc.fiocruz.br) on 2013-09-22T20:26:57Z No. of bitstreams: 1 MP 2007 - Renata Guimarães Dümpel.pdf: 4715942 bytes, checksum: 53a2859a38baf24dcf47f09d2380da18 (MD5) / Made available in DSpace on 2013-09-22T20:26:57Z (GMT). No. of bitstreams: 1 MP 2007 - Renata Guimarães Dümpel.pdf: 4715942 bytes, checksum: 53a2859a38baf24dcf47f09d2380da18 (MD5) / Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Rio de Janeiro, RJ, Brasil. / As políticas públicas educacionais atuais enfatizam a necessidade de práticas pedagógicas inclusivas para alunos com necessidades educacionais especiais. Entende-se por educação especial, a modalidade de educação escolar, oferecida preferencialmente na rede regular de ensino, para educandos com necessidades especiais, uma prática de política social que também chamamos de inclusão. Falar em inclusão é deparar-se com uma situação de conflito, pois ao mesmo tempo em que esses alunos têm amparo legal para freqüentar o ambiente de ensino regular, enfrentam também diversas dificuldades, incluindo: a) falta de preparo dos professores, b) preconceito dos pais de crianças sem necessidades especiais, ou/e c) inobservância do cumprimento de todas as exigências que demandam o adequado atendimento dessa clientela. Com base nas dificuldades encontradas para incluir alunos com necessidades especiais, nosso projeto tem como objetivo produzir modelos bidimensionais e tridimensional interativos relacionados ao tema Célula do tópico Biologia Celular/Citologia da área de Biologia que sejam ao mesmo tempo facilitadores e estimuladores do processo ensino-aprendizagem e que sejam inclusivos para todas as crianças, com ou sem necessidades educacionais especiais. O tema Célula apresenta complexidade contextual exigindo alto grau de abstração e com descrição nos livros didáticos que não atende, por exemplo, ao modo de aprendizagem, eminentemente tátil dos alunos com necessidades especiais visuais. A partir de um levantamento em livros didáticos, produzimos um modelo celular tridimensional e um atlas contendo organelas bidimensionais e explicações escritas e em braile. Esses materiais foram testados junto a alunos videntes e com necessidades especiais, e com professores da rede pública de ensino, sendo bem aceito pelos alunos que o consideraram muito bom e com capacidade de facilitar a compreensão do tema. De forma similar, os professores avaliaram também consideraram o material como um facilitador do processo de ensino aprendizagem, já que os aspectos visual e tátil, segundo esses profissionais, podem ajudar ao aluno a memorizar e aprender. Com base nos resultados obtidos, acreditamos que os modelos produzidos poderão atuar de forma positiva, não só no processo de inclusão de alunos com deficiência visual, como na compreensão da estrutura celular e seus componentes para todos os alunos envolvidos no processo de ensino aprendizagem. / The current educational policies emphasize the need for inclusive teaching practices for students with special educational needs. It is understood by special education, the type of education offered preferably in the regular education for learners with special needs, a practice of social policy that also call for inclusion. Speaking inclusion is faced with a conflict situation, because while these students have legal grounds to attend the regular education environment, also face various difficulties, including: a) lack of preparation of teachers, b) bias parents of children without special needs, or / and c) failure of the fulfillment of all requirements that require the adequate treatment of this clientele. Based on the difficulties encountered to include students with special needs, our project aims to produce two and three dimensional interactive models related to the theme topic of Cell Biology Cellular / Cytology in the area of biology that are both stimulating and facilitating the teaching-learning process and that is inclusive for all children, with or without special education needs. The theme presents Cell contextual complexity requiring a high degree of abstraction and description in the textbooks that do not meet, for example, the learning mode, essentially tactile learners with visual disabilities. From a survey of textbooks, produced a three-dimensional cell model and a two-dimensional atlas satisfaction and organelles and explanations written in Braille. These materials were tested with students seers, with special needs, and teachers in public schools being well received by students who found them very good and able to facilitate understanding of the subject. Similarly, teachers also evaluated the material considered as a facilitator of teaching and learning process, since the visual and tactile aspects, according to these professionals can help the students to memorize and learn. Based on these results, we believe that the models produced may act positively, not just in the process of including pupils deficient visual, as in the understanding of cell structure and its components for all students involved in teaching and learning.
190

An essay on impression management: three randomized experiments with financial analysts

Leite, Rodrigo de Oliveira 19 November 2015 (has links)
Submitted by Rodrigo de Oliveira Leite (rodrigo.leite2015@fgvmail.br) on 2015-12-15T13:33:15Z No. of bitstreams: 1 d-final.pdf: 1134926 bytes, checksum: 9a3b40813a4fdd6fb3dbbf240281c3a7 (MD5) / Approved for entry into archive by ÁUREA CORRÊA DA FONSECA CORRÊA DA FONSECA (aurea.fonseca@fgv.br) on 2016-01-27T19:47:33Z (GMT) No. of bitstreams: 1 d-final.pdf: 1134926 bytes, checksum: 9a3b40813a4fdd6fb3dbbf240281c3a7 (MD5) / Approved for entry into archive by Marcia Bacha (marcia.bacha@fgv.br) on 2016-02-01T13:49:51Z (GMT) No. of bitstreams: 1 d-final.pdf: 1134926 bytes, checksum: 9a3b40813a4fdd6fb3dbbf240281c3a7 (MD5) / Made available in DSpace on 2016-02-01T13:50:09Z (GMT). No. of bitstreams: 1 d-final.pdf: 1134926 bytes, checksum: 9a3b40813a4fdd6fb3dbbf240281c3a7 (MD5) Previous issue date: 2015-11-19 / This thesis aims to explore the concept of impression management from the financial analysts’ point of view. Impression management is the definition of the act of an agent manipulating an impression that another person have of this agent, in the context of this thesis it happens when a company make graphics to disclosure financial-accounting information in order to manipulate the market’s perception of their performance. Three types of impression management were analyzed: presentation enhancement (color manipulation), measurement distortion (scale manipulation) and selectivity (the disclosure of positive information only). While presentation enhancement improved only the most impulsive financial analysts’ perception of firm’s performance, the measurement distortion improved the perception of performance for both groups of financial analysts (impulsive and reflective). Finally, selectivity improved the financial analysts’ perception of firm’s performance for both groups (impulsive and reflective), although impulsive financial analysts assigned lower ratings when compared to their reflective peers, on average, to a hypothetical company. / Esta dissertação tem como alvo explorar o impression management (gerenciamento de impressão) do ponto de vista dos analistas financeiros. O gerenciamento de impressão acontece quando alguém tenta manipular a impressão de terceiros quanto à sua pessoa, no âmbito desta dissertação ele acontece quando uma empresa manipula gráficos com informações financeirocontábeis para manipular a impressão do mercado quanto à sua performance. Foram analisados três tipos de gerenciamento de impressão: presentation enhancement (manipulação de cores), measurement distortion (manipulação de escalas) e selectivity (divulgação apenas de informações positivas). Enquanto o presentation enhancement melhorou a percepção de performance apenas para os analistas financeiros mais impulsivos, o measurement distortion melhorou a percepção de performance para ambos os grupos de analistas (impulsivos e reflexivos). E, por fim, selectivity melhorou a percepção de performance para ambos os grupos de analistas (impulsivos e reflexivos), porém analistas impulsivos deram menores ratings em média do que os reflexivos para a empresa hipotética deste estudo.

Page generated in 0.0784 seconds