Spelling suggestions: "subject:"magnetization."" "subject:"agnetization.""
351 |
Cation deficiency in lanthanum manganitesBerenov, Andrey Valdimirovich January 1999 (has links)
No description available.
|
352 |
Toward the characterization of micro- and macro- traumatisms of the human cervical spinal cord in rugby : a multimodal approach combining magnetic resonance imaging and biomechanical finite element modelling / Vers la caractérisation des micros et macro-traumatismes de la moelle épinière cervicale dans la pratique du rugby : une approche multimodale combinant imagerie par résonnance magnétique et modélisation biomécanique par éléments finisRasoanandrianina, Rivo 08 January 2019 (has links)
Dans la pratique du rugby à XV, l’intégrité de la moelle épinière (ME) est menacée par les rares macro-traumatismes du rachis cervical, et par les chargements répétitifs entrainant l’apparition de pathologies dégénératives. Comment quantifier ces altérations, quels sont les mécanismes qui les président ?Pour aborder ces questions, la faisabilité et l’intérêt d’un protocole IRM multiparamétrique en contexte dégénératif ont tout d’abord été investigués. Puis, une récente technique de relaxométrie T1 3D et une acquisition ihMT multi-coupes à multiples orientations permettant d’évaluer le contenu macromoléculaire des tissus, en particulier la myéline, ont été développées pour évaluer le caractère diffus des altérations. Préliminairement appliqué sur quelques joueurs, ce protocole a ainsi démontré la faisabilité d’une exploration approfondie par IRM multiparamétrique de la ME cervicale dans le rugby.En complément de cela, une étude préliminaire utilisant un modèle éléments finis (MEF) détaillé a été menée pour évaluer la réponse mécanique des sous-régions de la ME soumises à des chargements mécaniques primaires. Par la suite, une étude préliminaire des risques neurologiques liés à un canal vertébral étroit (observé chez certains joueurs) a été conduite en modifiant la géométrie du MEF. A l’interface entre l’IRM et la biomécanique, ces travaux préliminaires ont posé les premiers jalons pour une caractérisation fine et robuste des altérations tissulaires au niveau médullaire dans le rugby. A terme, cette approche permettrait de proposer de nouveaux éléments pour une éventuelle amélioration du bilan d’aptitude des joueurs et de proposer des programmes préventifs améliorés. / In Rugby Union practice, the cervical spinal cord (CSC) could be involved in rare cervical spine (CS) traumatic injuries and also be threatened by the neck exposure to repetitive impacts assumed to induce early degenerative tissue alterations. How to quantify these impairments? What are the underlying pathophysiological mechanisms? To answer these questions, efforts were first directed towards the investigative potential of an advanced multiparametric Magnetic Resonance Imaging (MRI) protocol in degenerative contexts. Then, a new MRI protocol covering the whole CSC, including a recent 3D T1 relaxometry technique and a multi-slice multi-angle ihMT acquisition evaluating tissue myelin-content, was optimized. Preliminarily-applied to few players, this new optimized protocol showed the feasibility of a fine and diffuse CSC characterization in rugby. In parallel and as a complement, preliminary finite element modelling (FEM) analyses were also conducted to evaluate the mechanical responses of CSC sub-regions under primary loading mechanisms. Then, the same loading mechanisms were applied to a geometrically-modified FEM reproducing a narrow vertebral canal, reported to occur in some players therefore allowing to evaluate the effect of rugby-related CS degenerative changes on the CSC mechanical response under traumatic loadings. These preliminary, interdisciplinary and complementary works lay the ground for a fine structural and mechanical characterization of CSC tissues in rugby players, which would eventually allow to propose improved aptitude-to-play evaluation criteria as well as improved preventive programs.
|
353 |
Contrôle non destructif par courants de Foucault de milieux ferromagnétiques : de l’expérience au modèle d’interaction / Eddy current non destructive testing of ferromagnetic materials : experimentation and modelingZorni, Chiara 28 February 2012 (has links)
La problématique étudiée est le contrôle non destructif par courants de Foucault de matériaux ferromagnétiques à l’aide d’un capteur à magnétorésistance géante (GMR). Durant ces travaux deux aspects complémentaires ont été abordés : l’un concerne la mesure expérimentale pour essayer de quantifier et de s’affranchir du bruit de structure et du champ magnétique rémanent, l’autre le développement d’un modèle numérique d’interaction. En ce qui concerne la partie expérimentale plusieurs études avec un capteur GMR qui présente un intérêt particulier en raison de sa bonne sensibilité à basses fréquences, de sa dynamique et de la relative simplicité de mise en œuvre ont été conduites et ont permis d’identifier et quantifier les phénomènes d’artefacts spécifiques aux matériaux ferromagnétiques : le bruit de structure et le champ magnétique rémanent. Une solution basée sur une combinaison linéaire des données expérimentales obtenues à plusieurs fréquences est appliquée pour atténuer le bruit dû à la structure du matériau. Le champ magnétique rémanent a été analysé expérimentalement et un circuit d’asservissement permettant de fixer un point de polarisation dans la zone de fonctionnement linéaire de la GMR et ainsi d’atténuer les perturbations dues aux champs magnétiques rémanents est mis en place. En parallèle et dans l’optique de développer des outils de simulation permettant de mieux comprendre les phénomènes physiques et ainsi d’optimiser les procédés de contrôle, un modèle numérique d’interaction simulant le cas du contrôle d’une pièce plane ferromagnétique d’une ou plusieurs couches pouvant contenir un ou plusieurs défauts est développé. Il étend un modèle déjà existant dans un cas non-ferromagnétique déjà intégré dans la plateforme de simulation CIVA développé par le CEA-LIST et permettant la simulation du Contrôle Non Destructif par Courants de Foucault. Il est basé sur une méthode d’intégrales de volume (VIM) et l’utilisation des tenseurs ou dyades de Green. La solution est obtenue après la discrétisation du volume de calcul et l’application d’une variante de Galerkin de la Méthode des Moments (MoM). La réponse de la sonde est ensuite calculée en appliquant le théorème de réciprocité de Lorentz. Des collaborations avec deux laboratoires universitaires (le Laboratoire de Génie Électrique de Paris (LGEP) et l’Université de Cassino (Italie)) ont permis de comparer les résultats issus des trois différents modèles sur un cas de la littérature. Les résultats se sont révélés satisfaisants et plusieurs études de convergence ont permis d’analyser la stabilité du modèle. / The aim of this work is the eddy-current testing (ECT) of ferromagnetic materials within magnetic sensors, such as Giant Magneto-Resistances (GMR). Two complementary aspects have been studied. Experimental measurements have been carried out in order to quantify and minimize the noise coming from the materials structure and residual magnetization. On the other hand, a model has been developed in order to be able to simulate the electromagnetic interactions between a ferromagnetic specimen and the EC probe. The GMR sensors are characterized by high sensitivity at low frequency, large dynamic range and are relatively easy to implement. The studies carried out during this thesis allowed us to identify and analyse the “ghost signals” due to magnetic materials. In order to minimize the noise coming from the materials structure, a linear multi-frequencies combination of experimental signals has been employed successfully and the detection of buried flaws has been improved. The residual magnetization in ferromagnetic materials has been experimentally analyzed and an electronic system has been realized to fix the polarisation point of the sensor in the linear response zone of the GMR. Thus, disturbances caused by residual magnetization are successfully reduced. Beside, in order to develop simulation tools aiming at improving the understanding of experimental signals and optimizing the performances of ECT procedures, a model has been developed to simulate the ECT of planar, stratified and ferromagnetic materials affected with multiple flaws. CEA developed for many years semi-analytical models embedded into the simulation platform CIVA dedicated to non-destructive testing. Following a previous work carried out at the laboratory and already integrated in the simulation platform CIVA, developed at CEA-LIST, the new model extends CIVA functionalities to the ferromagnetic planar case. Simulation results are obtained through the application of the Volume Integral Method (VIM) which involves the dyadic Green’s functions. Two coupled integral equations have to be solved and the numerical resolution of the system is carried out using the classical Galerkin variant of the Method of Moments (MoM). Finally, the probe response is calculated by application of the Lorentz reciprocity theorem. A collaboration with the University of Cassino (Italy) and Laboratoire de Génie Electrique de Paris (France) allowed us to compare the three models on experimental and numerical results from literature. Results showed a good agreement between the three models and the model stability has been analyzed.
|
354 |
Development of FENSI (Flow Enhanced Signal Intensity) perfusion sequence and application to the characterization of microvascular flow dynamics using MRI / Développement d’une nouvelle séquence d’IRM de perfusion (FENSI - Flow Enhanced Signal Intensity) et application à la caractérisation de la dynamique des flux micro-vasculaires par IRMReynaud, Olivier 24 September 2012 (has links)
Les récents développements en RMN et IRM ont eu un impact spectaculaire sur l’imagerie médicale et aident à appréhender de manière fonctionnelle et non invasive de nombreux mécanismes cérébraux. L’imagerie par RMN de perfusion a notamment une importance primordiale en neuroimagerie clinique dans la caractérisation de nombreux désordres cérébrovasculaires (tumeurs cérébrales, AVC). Cependant il n’existe pour le moment aucune technique qui quantifie de manière non-invasive le bon fonctionnement du réseau microvasculaire cérébral. Cette thèse se concentre sur l’utilisation de la séquence FENSI en imagerie préclinique à haut et ultra haut champ magnétique pour caractériser et quantifier la dynamique des flux microvasculaires dans le cerveau du rat. Nous présentons les enjeux de l’IRM de perfusion en neuroimagerie, ainsi que les contraintes associées aux méthodes conventionnelles – méthode de marquage de spin artériel (ASL) et IRM dynamique de contraste de susceptibilité magnétique (DSC-MRI) – dont la technique FENSI peut d’affranchir. Cependant d’autres problèmes sont adressés. Les images acquises avec FENSI et pondérées en flux peuvent être contaminées par des effets de transferts d’aimantation (MT) qui empêchent de quantifier le débit sanguin cérébral. Une première technique de correction de ces effets par post-traitement est proposée. Nous dérivons les premières cartes de flux sanguin cérébral chez le rat à 7 tesla. Une seconde approche est considérée, où les effets MT dans les images acquises avec et sans saturation des spins circulant dans le réseau capillaire (tag/control) se compensent. Cette seconde approche permet une vraie quantification non-invasive du flux sanguin cérébral (CBFlux) in-vivo. Le réseau microvasculaire est caractérisé via FENSI à différents stages du développement tumoral dans un modèle de gliosarcome cérébral (9L) chez le rat. Les mesures de flux mettent en évidence une forte hétérogénéité de développement vasculaire des gliosarcomes peu avancés (diamètre inférieur à 3 mm). A un stade avancé, le flux sanguin est significativement plus faible dans la tumeur (-40 %) que dans le sous cortex, en bon accord avec la littérature sur ce type de gliosarcome. De plus, les cartes paramétriques de flux permettent de distinguer différents compartiments dans la tumeur. Une comparaison avec une méthode de marquage endothélial sur coupes histologiques suggère que le flux sanguin calculé avec FENSI est corrélé avec la concentration locale en micro-vaisseaux. Nous avons également tentés d’évaluer la dynamique temporelle de la réponse vasculaire à un stimulus et d’appliquer FENSI à l’IRM fonctionnelle (IRMf). Nous avons mis en place un protocole d’IRMf chez le rat à 7 tesla et caractérisé la réponse hémodynamique obtenue par contraste BOLD. A 7 tesla la technique FENSI souffre d’un faible SNR temporel et semble plus adaptée pour quantifier des changements métaboliques associées à de longues plages temporelles. L’implémentation de la séquence à ultra-haut champ (17.2 tesla) donne lieu à de sérieux espoirs en IRMf. De plus, nous mettons en évidence à 17.2 tesla des contrastes spécifiques à l’utilisation de différents anesthésiques utilisés en routine à l’hôpital. La méthode que nous avons mise en place peut être sensibilisée à de nombreuses vitesses, augmentant le nombre de ses applications potentielles. Ainsi, un choix judicieux de paramètres permet d’explorer le volume sanguin ou l’orientation du débit ciblé. Les forces et faiblesses de la méthode sont détaillées. L’utilisation de FENSI n’est en général pas justifiée par un gain de signal par rapport à des séquences ASL optimisées, mais bénéficie de l’actuelle montée en champ des imageurs cliniques pour être étudiée. Les applications potentielles varient de l’IRMf et l’imagerie de diffusion au suivi pharmacologique et diagnostic de désordres cérébrovasculaires, dont l’étude via ASL est limitée dû à l’allongement des temps de transit sanguins. / The discoveries, implementations and developments of NMR and MRI have had a major impact in medical imaging. Compared to other imaging modalities (PET, SPECT, CT), current MRI research helps to further and better understand the inner mechanisms of the human body in a less invasive manner. In clinical neuroimaging, perfusion MRI is of spectacular importance to study cerebrovascular diseases and cancer. However, at the moment, there is no perfusion MRI sequence that allows for a complete, non-invasive and precise quantification of microvascular flow dynamics. This work focuses on the use of the recently introduced Flow Enhanced Signal Intensity method (FENSI) to characterize and quantify vasculature at capillary level, at high and ultra high magnetic field (7 and 17.2 tesla). For that purpose, the possible quantification of blood flux with FENSI is explored in vivo. The combination of flux quantification and flow-enhanced signal (compared to Arterial Spin Labeling) can make of FENSI an ideal method to characterize in a complete non-invasive way the brain microvasculature. After removal of magnetization transfer (MT) effects, the blood flow dynamics are studied with FENSI in a very aggressive and propagative rat brain tumor model: the 9L gliosarcoma. The objective is to assess whether FENSI is suitable for a longitudinal non-invasive characterization of microvascular changes associated with tumor growth. The results obtained with FENSI are compared with literature on 9L perfusion and immuno-histochemistry. In the first paper published on FENSI, a first glance was also casted on the potential of the flow enhanced technique when applied to fMRI. The results obtained at the time were contaminated by MT effects. With the implementation of a new MT-free FENSI technique, the possibility to map the brain cerebral functioning based on a quantitative physiological parameter (CBFlux) more directly related to neuronal activity than the usual BOLD signal is within reach. At ultra high field, the influence of different anesthetics on the rat brain microvascular network and BOLD contrast is also considered. After many developments around the FENSI technique, the method is compared to classical ASL and DSC perfusion MRI sequences. The strengths and weaknesses of the FENSI method, its characteristics, ‘precautions for use’, and potential main applications are detailed and discussed.
|
355 |
Relative number squeezing in a Spin-1 Bose-Einstein condensateBookjans, Eva M. 15 November 2010 (has links)
The quantum properties of matter waves, in particular quantum correlations and entanglement are an important frontier in atom optics with applications in quantum metrology and quantum information. In this thesis, we report the first observation of sub-Poissonian fluctuations in the magnetization of a spinor 87Rb condensate. The fluctuations in the magnetization are reduced up to 10 dB below the classical shot noise limit. This relative number squeezing is indicative of the predicted pair-correlations in a spinor condensate and lay the foundation for future experiments involving spin-squeezing and entanglement measurements. We have investigated the limits of the imaging techniques used in our lab, absorption and fluorescence imaging, and have developed the capability to measure atoms numbers with an uncertainly < 10 atoms. Condensates as small as ≈ 10 atoms were imaged and the measured fluctuations agree well with the theoretical predictions. Furthermore, we implement a reliable calibration method of our imaging system based on quantum projection noise measurements. We have resolved the individual lattice sites of a standing-wave potential created by a CO2 laser, which has a lattice spacing of 5.3 µm. Using microwaves, we site-selectively address and manipulate the condensate and therefore demonstrate the ability to perturb the lattice condensate of a local level. Interference between condensates in adjacent lattice sites and lattice sites separated by a lattice site are observed.
|
356 |
Magnetostatics and Dynamics of Ion Irradiated NiFe/Ta Multilayer Films Studied by Vector Network Analyzer Ferromagnetic ResonanceMarkó, Daniel 31 January 2011 (has links) (PDF)
In the present work, the implications of ion irradiation on the magnetostatic and dynamic properties of soft magnetic Py/Ta (Py = Permalloy: Ni80Fe20) single and multilayer films have been investigated with the main objective of finding a way to determine their saturation magnetization. Both polar magneto-optical Kerr effect (MOKE) and vector network analyzer ferromagnetic resonance (VNA-FMR) measurements have proven to be suitable methods to determine µ0MS, circumventing the problem of the unknown effective magnetic volume that causes conventional techniques such as SQUID or VSM to fail. Provided there is no perpendicular anisotropy contribution in the samples, the saturation magnetization can be determined even in the case of strong interfacial mixing due to an inherently high number of Py/Ta interfaces and/or ion irradiation with high fluences.
Another integral part of this work has been to construct a VNA-FMR spectrometer capable of performing both azimuthal and polar angle-dependent measurements using a magnet strong enough to saturate samples containing iron. Starting from scratch, this comprised numerous steps such as developing a suitable coplanar waveguide design, and writing the control, evaluation, and fitting software.
With both increasing ion fluence and number of Py/Ta interfaces, a decrease of saturation magnetization has been observed. In the case of the 10×Py samples, an immediate decrease of µ0MS already sets in at small ion fluences. However, for the 1×Py and 5×Py samples, the saturation magnetization remains constant up to a certain ion fluence, but then starts to rapidly decrease. Ne ion irradiation causes a mixing and broadening of the interfaces. Thus, the Py/Ta stacks undergo a transition from being polycrystalline to amorphous at a critical fluence depending on the number of interfaces. The saturation magnetization is found to vanish at a Ta concentration of about 10–15 at.% in the Py layers. The samples possess a small uniaxial anisotropy, which remains virtually unaffected by the ion fluence, but slightly reduces with an increasing number of Py/Ta interfaces. In addition to magnetostatics, the dynamic properties of the samples have been investigated as well. The Gilbert damping parameter α increases with both increasing number of Py/Ta interfaces and higher ion fluences, with the former having a stronger influence. The inhomogeneous linewidth broadening ΔB0 increases as well with increasing number of Py/Ta interfaces, but slightly decreases for higher ion fluences. / In dieser Dissertation ist der Einfluss von Ionenbestrahlung auf die magnetostatischen und dynamischen Eigenschaften von weichmagnetischen Py/Ta-Einzel- und Multilagen (Py = Permalloy: Ni80Fe20) untersucht worden, wobei das Hauptziel gewesen ist, eine Methode zur Bestimmung der Sättigungsmagnetisierung zu finden. Sowohl polare magneto-optische Kerr-Effektmessungen (MOKE) als auch ferromagnetische Resonanzmessungen mittels eines Vektornetzwerkanalysators (VNA-FMR) haben sich als geeignet erwiesen, um µ0MS zu bestimmen, wobei das Problem des unbekannten effektiven magnetischen Volumens umgangen wird, welches bei der Verwendung von Techniken wie SQUID oder VSM auftreten würde. Unter der Voraussetzung, dass die Proben keinen senkrechten magnetischen Anisotropiebeitrag besitzen, kann die Sättigungsmagnetisierung selbst im Fall starker Grenzflächendurchmischung infolge einer großen Anzahl an Py/Ta-Grenzflächen und/oder Ionenbestrahlung mit hohen Fluenzen bestimmt werden.
Ein weiterer wesentlicher Bestandteil dieser Arbeit ist die Konstruktion eines VNA-FMR-Spektrometers gewesen, welches vollautomatisiert ist, polare und azimutale Winkelabhängigkeiten messen kann und einen Magneten besitzt, der Proben, die Eisen beinhalten, sättigen kann. Von Grund auf beginnend umfasste dies zahlreiche Schritte wie z. B. die Entwicklung eines geeigneten koplanaren Wellenleiterdesigns sowie das Schreiben von Steuerungs-, Auswertungs- und Fitprogrammen.
Mit steigender Fluenz und Zahl an Py/Ta-Grenzflächen ist eine Abnahme der Sättigungsmagnetisierung beobachtet worden. Im Fall der 10×Py-Proben findet diese bereits bei kleinen Fluenzen statt. Im Gegensatz dazu bleibt µ0MS der 1×Py- und 5×Py-Proben bis zu einer bestimmten Fluenz konstant, bevor sie sich dann umso schneller verringert. Die Bestrahlung mit Ne-Ionen verursacht eine Durchmischung und Verbreiterung der Grenzflächen. Infolgedessen erfahren die Py/Ta-Proben bei einer kritischen Fluenz, die von der Zahl der Grenzflächen abhängig ist, einen Phasenübergang von polykristallin zu amorph. Die Sättigungsmagnetisierung verschwindet ab einer Ta-Konzentration von etwa 10–15 Atom-% in den Py-Schichten. Die Proben besitzen eine kleine uniaxiale Anisotropie, die praktisch unbeeinflusst von der Fluenz ist, sich jedoch mit steigender Zahl an Py/Ta-Grenzflächen leicht verringert. Neben den statischen sind auch die dynamischen magnetischen Eigenschaften der Proben untersucht worden. Der Gilbert-Dämpfungsparameter α erhöht sich sowohl mit steigender Zahl an Py/Ta-Grenzflächen als auch mit höheren Fluenzen, wobei Erstere einen größeren Einfluss hat. Die inhomogene Linienverbreiterung ΔB0 nimmt ebenfalls mit steigender Zahl an Py/Ta-Grenzflächen zu, verringert sich jedoch bei größeren Fluenzen leicht.
|
357 |
Magnetization dynamics in all-optical pump-probe experiments: spin-wave modes and spin-current damping / Magnetisierungsdynamik in Pump-Probe Experimenten: Spinwellen Moden und Spinstrom DämpfungDjordjević Kaufmann, Marija 06 November 2006 (has links)
No description available.
|
358 |
Morphology-Induced Magnetic Phenomena Studied by Broadband Ferromagnetic ResonanceKörner, Michael 05 November 2013 (has links) (PDF)
In the present work, the influence of the morphology of thin ferromagnetic films on their static as well as dynamic magnetic properties was investigated by means of broadband ferromagnetic resonance (FMR). Using an ion beam erosion process the surface of the substrates was periodically modulated (ripples), where the modulation wavelength is determined by the ion energy. In this way a well-controllable roughness profile evolves ranging from a few ten up to several hundreds of nanometers in wavelength. The substrate’s surface profile in turn is repeated by films grown on top offering an easy and fast approach to investigate morphology influences on the magnetic properties. This work aims on modifications of the magnetic anisotropy as well as the FMR linewidth of the magnetic relaxation process.
Prior to magnetic investigations the existing FMR setup was extended to measure FMR spectra at a fixed microwave frequency while sweeping the external magnetic field. Furthermore, a software toolbox was developed to perform the data processing and evaluation.
Starting with the morphology influence on the magnetic anisotropy 10 nm thin Fe, Co, and Ni81Fe19 (Permalloy ≡ Py) films were deposited on rippled Si substrates. Due to Si displacements during ion erosion and natural oxidation the rippled Si substrates exhibit an amorphous surface causing a polycrystalline material growth. This leads to a suppression of magneto-crystalline anisotropy leaving only morphology-induced anisotropy contributions. Here, a uniaxial magnetic anisotropy (UMA) was observed that aligns its easy axis with the ripple ridges, whereas its strength decays with increasing ripple wavelength for all materials. From thickness-dependent measurements two characteristic regions were determined with competing uniaxial volume and surface anisotropy contributions. Underlined by micromagnetic simulations a dominant volume contribution was found in the thin region accompanied by magnetic moments nearly following the surface corrugation. In the thick region the UMA is controlled by dipolar stray fields at the surface.
In contrast to Si, ion eroded MgO keeps its crystal structure offering epitaxial growth of 10 nm thin single-crystalline Fe films. Consequently, a superposition of morphology-induced UMA and magneto-crystalline cubic anisotropy was observed. The direction of the ripple ridges is predetermined by the incident ion beam, which allows to freely orient the UMA’s direction with respect to the cubic anisotropy, offering a possibility for anisotropy engineering. In comparison to the planar reference case rippled magnetic films exhibit lower intrinsic and extrinsic relaxation contributions.
For the final part, 30 nm Py was grown on rippled Si covering modulation wavelengths λ ranging from 27 to 432 nm. Using magnetic force microscopy and holography measurements the dipolar stray fields above and inside the magnetic layer were characterized. For λ ≥ 222 nm, the stray fields act as scattering centers for spin waves triggering two-magnon scattering (TMS). This causes an apparent line broadening generating distinct peaks in the frequency-dependent linewidth whose position can be tuned by altering λ. These effects are understood in the framework of a perturbation theory of spin waves in periodically perturbed films recently presented in the literature. Furthermore, the in-plane angular dependence of the linewidth revealed a two-fold symmetry, which is not present for vanishing TMS at small λ. / In Rahmen dieser Arbeit wurde der Einfluss der Morphologie eines dünnen ferromagnetischen Films auf dessen statische und dynamische Eigenschaften mittels breitbandiger ferromag- netischer Resonanz (FMR) untersucht. Durch Ionenstrahl-Erosion wurde die Oberfläche des verwendeten Substrats periodisch moduliert (Ripple), wobei die Wellenlänge der Modulation durch die Ionenenergie bestimmt ist. Dies ermöglicht die kontrollierte Herstellung rauer Oberflächen mit Wellenlängen zwischen wenigen zehn bis zu einigen hundert Nanometern. Werden auf diesen Oberflächen Filme abgeschieden, übernehmen diese die Modulation. Somit ergibt sich eine einfache und schnelle Untersuchungsmöglichkeit der magnetischen Filmeigenschaften in Hinblick auf die Morphologie. Das Ziel dieser Arbeit ist die Untersuchung von Morphologieeinflüssen auf die magnetische Anisotropie sowie FMR-Linienbreite.
Im Vorfeld der magnetischer Untersuchungen wurde der bestehende FMR-Aufbau um einen Messmodus erweitert, sodass Messungen bei fester Mikrowellenfrequenz und gleichzeitigem Durchfahren eines externen magnetischen Feldes möglich wurden. Weiterhin wurde ein Softwarepaket für die Datenauswertung entwickelt.
Beginnend mit dem Morphologieeinfluss auf die magnetische Anisotropie wurden 10 nm dünne Fe, Co und Ni81Fe19 (Permalloy ≡ Py) Filme auf periodisch moduliertem Si abgeschieden. Durch Versetzungen während der Ionenstrahl-Erosion und Bildung einer natürlichen Oxidschicht bildet sich bei den verwendeten Substraten eine amorphe Oberfläche, was zu polykristallinem Schichtwachstum führt. Dadurch wird die magneto-kristalline Anisotropie unterdrückt und morphologie-induzierte Beiträge bestimmen die Anisotropie. Beobachtet wurde eine induzierte uniaxiale magnetische Anisotropie (UMA), deren leichte Richtung sich entlang der Ripple-Wellenzüge ausrichtet. Mittels schichtdickenabhängigen Messungen wurden zwei charakteristische Regionen mit konkurrierender uniaxialer Volumen- und Oberflächenanisotropie ermittelt. Dabei ist die Volumenkomponente im Bereich dünner Schichten vorherrschend und die magnetischen Momente richten sich entlang der Oberflächenmodulation aus. Für dickere Schichten ist die UMA dahingegen durch dipolare Streufelder bestimmt. Die experimentellen Funde werden in beiden Bereichen durch mikromagnetische Simulationen untermauert.
Im Gegensatz zu erodiertem Si behält MgO seine Kristallstruktur, was epitaktisch gewachsene, einkristalline Fe-Schichten von 10 nm Dicke ermöglicht. Folglich wurde eine Überlagerung aus induzierter und kristalliner Anisotropie beobachtet. Dadurch, dass die Richtung der Ripple durch die Richtung des Ionenstrahls während der Erosion vorgegeben wird, lässt sich die UMA frei gegen die kristalline Anisotropie drehen, was wiederum Möglichkeiten zur gezielten Beeinflussung der Anisotropie bietet. Im Hinblick auf die dynamischen magnetischen Eigenschaften führen Ripple zu einer Verringerung der intrinsischen und extrinsischen Relaxationsbeiträge.
Für den letzten Teil der Arbeit wurde 30 nm dünnes Py auf Si-Ripple gewachsen, wobei ein Wellenlängenbereich von λ = 27 nm bis 432 nm abgedeckt wurde. Mit Hilfe von magnetischer Kraftmikroskopie und Holographie wurden die dipolaren Streufelder über und in den Filmen untersucht. Ab λ ≥ 222 nm ermöglichen diese dipolaren Felder eine Streuung von Spinwellen, sodass Zwei-Magnonen-Streuung (TMS) auftritt. Dies führt zu einer scheinbaren Linienverbreiterung und äußert sich durch einzelne Peaks in der frequenzabhängigen Linienbreite. Letztere lassen sich in ihrer Frequenzposition durch die Wellenlänge des Substrates beeinflussen und können mittels einer kürzlich in der Literatur veröffentlichten Störungstheorie für Spinwellen in periodisch gestörten Filmen erklärt werden. Weiterhin wurde in der winkelabhängigen Linienbreite eine zweifache Symmetrie beobachtet, welche durch die TMS hervorgerufen wird und folglich nicht bei kleinen Wellenlängen zu beobachten ist.
|
359 |
Innovative MRT-Kontraste zur in-vivo-Differenzierung von Patienten mit typischem idiopathischen Parkinson und atypischen Parkinsonsyndromen / Innovative MRI contrasts for in-vivo-differentiation of patients with typical idiopathic Parkinson's syndromes and atypical parkinsonian syndromesPantel, Pia Marie 13 January 2014 (has links)
HINTERGRUND/ ZIELSETZUNG:
Vom idiopathischen Parkinsonsyndrom (IPS) können so genannte „atypische“ Parkinsonsyndrome (APS) mit einem Anteil von ca. 20% bezogen auf die Gesamtinzidenz unterschieden werden. Neben zusätzlichen Krankheitssymptomen und einem progredienteren Verlauf zeichnen sie sich durch eine schlechtere Prognose aus, die häufig auf einem Nichtansprechen auf eine dopaminerge Therapie beruht. Eine frühzeitige, korrekte Diagnose ist daher sehr entscheidend, aber im Einzelfall auch für Spezialisten äußerst schwierig. Trotz anerkannter klinischer Diagnosekriterien gibt es besonders im Frühstadium eine hohe Rate an Fehldiagnosen.
Das zur Zeit vorherrschende Verfahren in der bildgebenden Diagnostik ist die Magnetresonanztomographie, wobei die konventionelle, qualitative MRT bislang keine zufriedenstellenden Ergebnisse bezüglich ihrer Spezifität und Sensitivität gezeigt hat.
Die vorliegende Arbeit untersucht in einer direkten Vergleichsstudie das differenzialdiagnostische Potential der sogenannten „erweiterten“ quantitativen MRT-Verfahren.
MATERIAL UND METHODEN:
Ein Gesamtkollektiv von insgesamt 44 Probanden (IPS/ APS/ gesunde Kontrollen) durchlief ein umfassendes quantitatives MRT- Protokoll (R1/R2(*)-, DTI-, MTR- Mapping) um in manuell bilateral markierten, definierten Regionen (ROIs) in den Basalganglienkernen quantitative Parameter zu erheben.
ERGEBNISSE:
Die beste hochsignifikante Trennung der MSA-P- Patienten sowohl von IPS- Patienten (p = 0,001) als auch von Kontrollen (p = 0,004) konnte anhand des R2 * - Mappings im Putamen erreicht werden. Es zeigte sich eine Vorhersagekraft AUC von > / = 0,96 mit einer Sensitivität von 77,8 % (bei einer Spezifität von 100 %). Dies bestätigt die große Bedeutung der Eisensensitivität des R2*-Mappings bei der Identifizierung von MSA-P- Patienten.
Auch anhand des MTR-Mappings konnte eine MSA-P anhand der putaminalen (p = 0,005) und nigralen (p = 0,003) Signalveränderungen signifikant vorhergesagt werden.
Die beste signifikante Abgrenzung der PSP- Patienten von den Kontrollen gelang anhand der DTI- Messungen in der Substantia nigra (p = 0,001) sowie im Globus pallidus (p = 0,004).
Für die diagnostische Vorhersage eines IPS konnten keine nutzbaren Signalunterschiede festgestellt werden. Insbesondere in der Substantia nigra zeigten sich gegenüber Kontrollen keine signifikanten Gruppenunterschiede.
FAZIT:
Unter den angewandten MRT- Verfahren zeigt das R2*-Mapping die beste Vorhersagekraft zur Differenzierung der MSA von IPS- Patienten und das DTI- Mapping zur Identifizierung der PSP- Patienten. Das Besondere unseres Arbeitsansatzes war, im Gegensatz zu vorherigen Studien, die Durchführung der Untersuchung an nur einer Kohorte. Dadurch konnte die Güte der verschiedenen MRT-Verfahren direkt und quantitativ miteinander verglichen werden.
Insgesamt unterstreichen die Erkenntnisse dieser Arbeit den Stellenwert und die mögliche klinische Relevanz der quantitativen MRT, insbesondere bei der Identifizierung atypischer Parkinsonsyndrome.
|
360 |
Multiscale description of dynamical processes in magnetic media : from atomistic models to mesoscopic stochastic processes / Simulation multi-échelle des processus dynamiques dans les milieux magnétiques : depuis une modélisation atomistique vers la simulation de processsus mésoscopiques stochastiquesTranchida, Julien 01 December 2016 (has links)
Les propriétés magnétiques détaillées des solides peuvent être vu comme le résultat de l'interaction de plusieurs sous-systèmes: celui des spins effectifs, portant l'aimantation, celui des électrons et celui du réseau crystallin. Différents processus permettent à ces sous-systèmes d'échanger de l'énergie. Parmis ceux-ci, les phénomènes de relaxation jouent un rôle prépondérants. Cependant, la complexité de ces processus en rend leur modélisation ardue. Afin de prendre en compte ces interactions de façon abordable aux calculs, l'approche de Langevin est depuis longtemps appliquée à la dynamique d'aimantation, qui peut être vue comme la réponse collective des spins. Elle consiste à modéliser les interactions entre les trois sous-systèmes par des interactions effectives entre le sous-système d'intérêt, les spins, et un bain thermique, dont seulement la densité de probabilité constituerait une quantité pertinente. Après avoir présenté cette approche, nous verrons en quoi elle permet de bâtir une dynamique atomique de spin. Une fois son implémentation détaillée, cette méthodologie sera appliquée à un exemple tiré de la littérature et basé sur le superparamagnétisme de nanoaimants de fer. / Detailed magnetic properties of solids can be regarded as the result of the interaction between three subsystems: the effective spins, that will be our focus in this thesis, the electrons and the crystalline lattice. These three subsystems exchange energy, in many ways, in particular, through relaxation processes. The nature of these processes remains extremely hard to understand, and even harder to simulate. A practical approach, for performing such simulations, involves adapting the description of random processes by Langevin to the collective dynamics of the spins, usually called the magnetization dynamics. It consists in describing the, complicated, interactions between the subsystems, by the effective interactions of the subsystem of interest, the spins, and a thermal bath, whose probability density is only of relevance. This approach allows us to interpret the results of atomistic spin dynamics simulations in appropriate macroscopic terms. After presenting the numerical implementation of this methodology, a typical study of a magnetic device based on superparamagnetic iron monolayers is presented, as an example. The results are compared to experimental data and allow us to validate the atomistic spin dynamics simulations.
|
Page generated in 0.0843 seconds