• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 285
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 287
  • 287
  • 203
  • 191
  • 102
  • 86
  • 59
  • 47
  • 44
  • 36
  • 36
  • 34
  • 34
  • 34
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Avaliação do tratamento cirúrgico da obstrução da junção pielo-ureteral por meio de pieloplastia vídeo-laparoscópica robótica assistida / Evaluation of the management of ureteropelvic junction obstruction using a laparoscopic robotic approach

Chammas Júnior, Mário Fernandes 15 January 2016 (has links)
Objetivo: Avaliar os resultados iniciais e a curva de aprendizado dos primeiros 100 casos consecutivos do tratamento cirúrgico da obstrução da junção ureteropiélica por meio da pieloplastia robótica laparoscópica. Materiais e Métodos: Um total de 99 pacientes (41 homens e 58 mulheres), com idade média de 38 anos (18-81 anos), foi submetido a 100 pieloplastias robóticas laparoscópicas consecutivas (um procedimento bilateral), realizadas pelo mesmo cirurgião. A determinação da curva de aprendizado foi baseada na avaliação do tempo de anastomose, tempo cirúrgico, complicações precoces e tardias e resultados a longo prazo. Os casos foram divididos em grupos de 25 procedimentos consecutivos (grupos 1, 2, 3, 4) de acordo com a data, em ordem cronológica, em que foram submetidos ao procedimento. Os pacientes foram reavaliados pelos médicos do serviço de urologia 3, 12 meses e anualmente após o procedimento através de avaliação clínica, onde relatavam melhora ou não dos sintomas, e exames de imagem (urografia excretora e/ou cintilografia renal). Resultados: Não houve diferença significativa entre os grupos em relação à idade e índice de massa corpórea. O tempo médio para confecção da anastomose foi de 50,0, 36,8, 34,2 e 29,0 minutos para os grupos 1 a 4, respectivamente (p=0,137). O tempo cirúrgico médio foi 144,6, 119,2, 114,5 e 94,6 minutos, apresentando uma diferença estatisticamente significativa entre os grupos 1 vs. 2 (p=0,015), 1 vs. 3 (p=0,002), 1 vs. 4 (p < 0,001) e 2 vs. 4 (p=0,022). A internação hospitalar média foi de 7,08, 4,76, 4,88 e 4,20 dias, apresentando uma diferença estatisticamente significativa entre os grupos 1 vs. 2 (p < 0,001), 1 vs. 3 (p < 0,001) e 1 vs. 4 (p < 0,001). Complicações significativas (Clavien-Dindo grau > 3) ocorreram apenas no grupo 2 (2 complicações grau IIIb). Um paciente no grupo 1 necessitou de conversão cirúrgica para a via aberta devido a dificuldades técnicas na dissecção piélica. O seguimento pós-operatório médio foi de 50,6 meses. Houve perda de seguimento em três pacientes do grupo 1, um do grupo 2, dois do grupo 3 e um do grupo 4. Uma melhora significativa (clínica e radiológica) foi demonstrada em 98,9% dos casos nesta série. Em um seguimento tardio (50 meses) um paciente do grupo 3 apresentou um quadro de obstrução recorrente da JUP. Conclusão: Os resultados demonstram que a PRL é uma alternativa efetiva para o tratamento da estenose da JUP com altas taxas de sucesso e baixo índice de complicações. Apesar da presença de uma alta taxa de sucesso já nos primeiros casos uma queda significativa no tempo de internação e tempo cirúrgico foi evidente após a realização de 25 procedimentos. Aparentemente um número de 25 casos parece ser suficiente para um aprendizado efetivo das bases deste procedimento cirúrgico e uma diminuição sustentada de seu tempo operatório / Purpose: To evaluate the results and learning curve of laparoscopic robotic pyeloplasty during the initial 100 cases. Materials and Methods: A total of 99 patients (41 men, 58 women), with a median age of 38 years (range: 18-81 years), underwent 100 consecutive laparoscopic robotic pyeloplasties (one bilateral procedure), performed by the same surgeon. Learning curve estimations were used for anastomosis, operative time, early and late complications and long-term results. Sequential analyses were performed between the cases, which were divided in groups of consecutive 25 procedures (groups 1, 2, 3 and 4). Statistical analyses comparing the groups were performed. Results: All groups were similar with respect to age and body mass index. The median anastomosis time was 50.0, 36.8, 34.2 and 29.0 minutes for groups 1 to 4, respectively (p=0.137). Median operative time was 144.6, 119.2, 114.5 and 94.6 minutes, with a statistical difference present when comparing groups 1 and 2 (p=0.015), 1 and 3 (p=0.002), 1 and 4 (p < 0.001) and 2 and 4 (p=0.022). Mean hospital stay was 7.08, 4.76, 4.88 and 4.20 days, with a statistical difference present when comparing groups 1 and 2 (p < 0.001), 1 and 3 (p < 0.001) and 1 and 4 (p < 0.001). Major complications (Clavien-Dindo grade 3 or above) were present only in group 2 (2 grade IIIb complications). One patient in the group 1 required a conversion to open surgery due to dissection difficulties during pyelic exposure. The medium follow up was 50.6 months. Three patients in group 1, one in group 2, two in group 3 and one in group 4 were lost to follow-up. A significant improvement (clinical and radiological) was present in 98.9% of patients in this series. At a late follow-up (50 months) one patient in group 3 presented a recurrent ureteropelvic junction obstruction. Conclusion: Our results demonstrate that success rate of LARP is high and complication rates are low. The operative time (learning curve) decreased with experience, confirming the procedure\'s complexity. Although favorable results were already present in the first few cases, a significant decrease in hospital stay and surgical time was evident after 25 cases. Apparently, 25 cases appear to be a reasonable experience in order to decrease the operative time and master the basics of the procedure
102

Avaliação do valor prognóstico dos biomarcadores cardíacos perioperatórios em pacientes de moderado a alto risco cardiovascular submetidos à cirurgia não-cardíaca / Analysis of the maximal voluntary breath-holding time as pulmonary function tests in patients with obstructive ventilatory defects and normal controls

Borges, Flávia Kessler January 2011 (has links)
Introdução: O teste de apneia respiratória tem sido testado e demonstrou ser de utilidade clínica. Objetivos: Determinar o tempo de apneia voluntária máxima em pacientes com distúrbios ventilatórios obstrutivos (DVO) e em indivíduos normais e correlacionar os tempos de apneia com os testes de função pulmonar. Métodos: Foi realizado um estudo caso-controle incluindo pacientes com DVO (casos) e um grupo controle, composto por voluntários com espirometria normal, recrutados no Hospital de Clínicas de Porto Alegre (HCPA). A espirometria foi realizada com espirômetro computadorizado e o teste de apneia respiratória utilizando-se um sistema eletrônico microprocessado e um pneumotacógrafo ((Hans Rudolph ® – Kansas OH, EUA)– Kansas OH, EUA) como transdutor de fluxo. As curvas de fluxo respiratório foram exibidas em tempo real em um computador portátil e os tempos máximos de apneia voluntária inspiratória e expiratória (TAVIM e TAVEM) foram determinados a partir do sinal adquirido. Resultados: Um total de 35 pacientes com DVO (casos) e 16 controles foram incluídos no estudo. O TAVIM foi significativamente menor nos casos (22,3 ± 11,8 s) do que no grupo controle (31,5 ± 15,7 s) com p = 0,025. O TAVEM também foi significativamente menor nos casos (16,9 ± 6,6 s) do que no grupo controle (22,1 ± 7,9 s) com p = 0,017. Foram encontradas correlações positivas moderadas entre TAVIM e CVF (r = 0,476, p = 0,004) e entre TAVIM e VEF1 (r = 0,383, p = 0,023). Conclusões: As medidas de TAVIM e TAVEM foram significativamente menores nos casos do que nos controles, e o TAVIM teve correlação moderada com a CVF e VEF1. Estes resultados fornecem uma evidência adicional da utilidade clínica do tempo de apneia como teste de função pulmonar. / Introduction: Breath-holding test has been tested in some clinical scenarios and has proved to be of clinical utility. Objectives: To determine the maximum voluntary breath-holding time in patients with obstructive ventilator defects and in normal subjects and to correlate the breathholding times with pulmonary function tests. Methods: We conducted a case-control study including patients with obstructive ventilator defects and a control group consisted of volunteers recruited in the same hospital, with normal spirometry. Spirometry was performed using a computerized spirometer. The Breath-holding test was conducted using an electronic microprocessor and a (Hans Rudolph ® – Kansas OH, EUA)pneumotachograph and flow transducer. Respiratory flow curves were displayed in real time on a portable computer. The maximal voluntary apnea inspiratory and expiratory times (MVAIT and MVAET) were determined from the acquired signal. Results: A total of 35 patients with obstructive ventilatory defects and 16 controls met the inclusion criteria and were included in the analysis. The MVAIT was lower in cases (22.3 ± 11.8 seconds) than in controls (31.5 ± 15.7 seconds) (p=0.025). MVAET was also lower in cases than in controls (16.9 ± 6.6 vs. 22.1 ± 7.9; p=0.017). We found positive and significant correlations between MVAIT and FVC (L) (r=0.476; p=0.004) and between MVAIT and FEV1 (L) (r=0.383; p=0.023). Conclusions: MVAIT and MVAET were significant lower in patients with obstructive ventilatory defects than in controls, and that MVAIT was correlated positively with FVC and FEV1 in cases. Our results provide additional evidence of usefulness of MVAIT as a pulmonary function test.
103

Comparação entre dreno de sucção, pontos de adesão e cola de fibrina na prevenção de seroma em abdominoplastias / Suction drain, quilting suture and sealant fibrin to prevent seroma in abdominoplasties

Bercial, Marcos Eduardo [UNIFESP] 27 July 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-27 / INTRODUÇÃO: O seroma é uma das mais frequentes complicações em abdominoplastias. O ultrassom de parede abdominal tem sido considerado um dos melhores métodos não invasivos para o seu diagnóstico. Não há consenso na literatura de qual a melhor tática preventiva. OBJETIVO: Comparar o efeito do dreno de sucção a vácuo, dos pontos de adesão e da cola de fibrina, na prevenção de seroma em abdominoplastia. MÉTODO: Entre Março a Outubro de 2008, quarenta e três pacientes foram submetidas à abdominoplastia e distribuídas em: Grupo I .. Quinze pacientes com dreno de sucção a vácuo, Grupo II .. Treze pacientes com pontos de adesão entre o retalho e a aponeurose do músculo reto do abdome, Grupo III .. Quinze pacientes com cola de fibrina. A avaliação do seroma foi realizada por meio de ultrassonografia, em dois momentos diferentes: 15º e 30º dia de pós-operatório (PO). RESULTADOS: Observouse formação significativa de seroma no 15º PO do Grupo III (Hcalc=6,04; p<0,05). Houve redução significativa de seroma do 15º para o 30º PO nos três grupos, sendo Grupo I (p=0,0003); Grupo II (p=0,0011) e Grupo III (p=0,0003). CONCLUSÃO: O Grupo com pontos de adesão foi mais eficaz na prevenção de seroma, que os com dreno de sucção e cola de fibrina, no 15º dia de PO. / BACKGROUND: Seroma formation is one of the most frequent complications in abdominoplasty. The ultrasound made in abdominal walls is one of the best non-invasive methods to diagnose seroma. There is no evidence wich the best strategy in world literature. OBJECTIVE: This research investigated the formation of seroma in patients that have undergone abdominoplasties using three different methods: a vacuum suction drain, quilting suture and human fibrin sealant. METHOD: Between March and October 2008, 43 abdominosplasties were made in female patients. The sample was aleatory in three different groups: 15 patients used a vacuum suction drain (Group I), 13 patients received quilting suture between the flap and the muscle aponeurotics wall of the abdomen, without using vacuum suction drain (Group II) and in 15 patients the fibrin sealant was used without using vacuum suction drain (Group III). The study was focused in the investigation of the seroma formation, the evaluation of the three different methods used was accomplished through an ultrasound of the abdominal wall in two different moments: On the 15th day after the surgery and on the 30th day after the surgery. RESULTS: There was a significant amount of seroma on the 15th day after the surgery in Group III. There was a significant reduction of seroma formation from the 15th day to the 30th day after the surgery in all the groups. CONCLUSION: The group with quilting suture formed less seroma in the first ultrasound (15th day after the surgery). / TEDE / BV UNIFESP: Teses e dissertações
104

Estudo histomorfométrico de implantes craniofaciais em coelhos / Histomorphometric analysis of craniofacial implants placed in rabbits

Santos Júnior, João Ferreira dos [UNIFESP] 25 November 2010 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-11-25 / Objetivo: Análise histomorfométrica de implantes craniofaciais de diâmetros e formatos diferentes com superfície lisa e porosa em tíbia de coelhos. Método: Foram utilizados nessa pesquisa oito coelhos, adultos, fêmeas, albinos, raça Nova Zelândia. Instalamos 40 implantes craniofaciais com formatos cilíndricos (3,75 e 5,0 mm de diâmetro) e cônico (4,3 mm de diâmetro) ambos com 5 mm de comprimento. Os coelhos foram sacrificados 12 semanas, após a instalação dos implantes e as amostras de tecido ósseo submetidos à análise histomorfométrica, para avaliação do contato osso-implante e quantidade de osso formado entre as roscas dos implantes. Resultados: Os valores globais (média e desvio-padrão) do contato osso-implante dos implantes com superfície porosa foi de 73,77% ±6,25 e os implantes com superfície lisa 59,79% ±8,32. Individualmente os valores do contato osso-implante foram os seguintes: o implante poroso de 5,0 mm 72,67% ±7,44, implante liso de 5,0 mm 58,33% ±7,01, implante poroso 4,3 mm 76,80% ±5,58, implante liso 4,3 mm 61,26% ±9,78 e implante poroso 3,75 mm 71,84% ±5,24. Conclusão: existe maior valor estatisticamente significante (p<0,001) de contato osso-implante nos implantes com superfície tratada. Não existe diferença estatisticamente significante, quanto ao contato osso-implante, entre os diferentes tamanhos de implante (3,75 mm / 4,3 mm / 5,0 mm) e formatos dos mesmos (cônico e cilíndrico). / Purpose: Histomorphometric analysis of craniofacial implants of different shapes and diameters, with machined and porous surfaces, placed in the tibia of rabbits. Method: In this study, 40 craniofacial implants with cylindrical shapes (3.75 and 5.0 mm in diameter) and conical (4.3 mm in diameter) both with 5 mm in length were implanted in the tibia of 8 adult female New Zealand white rabbits. The animals were sacrificed 12 weeks after installation of implants. Bone specimens were prepared for histomorphometric assessment of the bone-to-implant contact and the bone volume formation between implant threads. Results: The overall bone-to-implant contact values (mean and standard deviation) were 73.77 ± 6.25% with porous surface implants and 59.79 ± 8.32% with machined surface implants. Individual group values of bone-to-implant contact were as follows: 5.0 mm porous implant 72.67 ± 7.44%; 5.0 mm machined implant 58.33 ± 7.01%; 4.3 mm porous implant 76.80 ± 5.58%; 4.3 mm machined implant 61.26 ± 9.78%; and 3.75 mm porous implant 71.84 ± 5.24%. Conclusion: There was statistically significant greater bone-to-implant contact values with porous surface implants (p <0.001). There was no statistically significant difference on the bone-to-implant contact between different implant sizes (3.75 mm / 4.3 mm / 5.0 mm) and shapes (cylindrical and conical). / TEDE / BV UNIFESP: Teses e dissertações
105

Morbimortalidade relacionada à disfunção renal aguda estimada pelo critério pRIFLE em crianças submetidas a cirurgia cardíaca

El Halal, Michel Georges dos Santos January 2012 (has links)
Objetivos: O objetivo deste estudo foi investigar associação entre ocorrência de disfunção renal aguda de acordo com o critério RIFLE pediátrico (pRIFLE) e desfechos negativos em crianças em pós-operatório de cirurgia cardíaca. Métodos: Crianças submetidas à cirurgia cardíaca em um hospital terciário no sul do Brasil foram acompanhadas da internação até a alta da Unidade de Terapia Intensiva Pediátrica (UTIP) ou óbito. A variável de exposição foi ocorrência de disfunção renal aguda de acordo com o critério pRIFLE, que divide disfunção renal aguda em 3 categorias: R-Risco, I-Lesão, F-Insuficiência. Os desfechos estudados foram morte, tempo de ventilação mecânica (VM) e tempo de internação na UTIP. Resultados: Oitenta e cinco crianças foram estudadas. Quarenta e sete (55,3%) não desenvolveram disfunção renal aguda durante a internação na UTIP, enquanto que 22 (25,9%), 7 (8,2%) e 9 (10,6%) foram classificadas nos grupos R, I, e F, respectivamente. A incidência de óbito foi de 18,4% e de 4,2% nos pacientes com e sem disfunção renal aguda, respectivamente. Comparado a crianças que não desenvolveram disfunção renal, a razão de chances ajustada de óbito foi 1,046 (0,09-11,11), 8,358 (1,32-52,63) e 7,855 (1,53-40,29) nos grupos R, I, e F, respectivamente (p = 0,022). Os tempos de VM e de internação na UTIP foram significativamente maiores nas crianças com disfunção renal aguda. Conclusões: Ocorrência de disfunção renal aguda de acordo com o critério pRIFLE está associado com maior morbidade (maior tempo de VM e de internação na UTIP) e maior mortalidade em crianças em pós-operatório de cirurgia cardíaca. / Objectives: This study aims to investigate association between occurrence of acute kidney injury (AKI) according to pediatric RIFLE (pRIFLE) criteria and adverse outcomes in children after heart surgery. Methods: Children submitted to open heart surgery in a tertiary hospital in Southern Brazil were followed from arrival until discharge from the Pediatric Intensive care Unit (PICU) or death. The exposition variable was occurrence of AKI according to pRIFLE criteria, which divides AKI in three categories: R-Risk, I-Injury, F-Failure. The outcomes studied were death, length of mechanical ventilation (MV) and length of PICU stay. Results: Eighty five children were studied. Forty seven (55.3%) did not have AKI during PICU stay, while 22 (25.9%), 7 (8.2%) and 9 (10.6%) were classified as R, I and F, respectively. The incidence of death was 18.4% and 4.2% in patients with and without AKI, respectively. Comparing to children who did not develop AKI, the adjusted odds ratio for death was 1.046 (0.09-11.11), 8.358 (1.32-52.63) and 7.855 (1.53-40.29) in the R, I and F group, respectively (p = 0.022). Lengths of MV and of PICU stay were significantly higher in those with AKI. Conclusions: Occurrence of AKI according to pRIFLE criteria is associated to adverse outcomes in children after open heart surgery.
106

Avaliação do valor prognóstico dos biomarcadores cardíacos perioperatórios em pacientes de moderado a alto risco cardiovascular submetidos à cirurgia não-cardíaca / Analysis of the maximal voluntary breath-holding time as pulmonary function tests in patients with obstructive ventilatory defects and normal controls

Borges, Flávia Kessler January 2011 (has links)
Introdução: O teste de apneia respiratória tem sido testado e demonstrou ser de utilidade clínica. Objetivos: Determinar o tempo de apneia voluntária máxima em pacientes com distúrbios ventilatórios obstrutivos (DVO) e em indivíduos normais e correlacionar os tempos de apneia com os testes de função pulmonar. Métodos: Foi realizado um estudo caso-controle incluindo pacientes com DVO (casos) e um grupo controle, composto por voluntários com espirometria normal, recrutados no Hospital de Clínicas de Porto Alegre (HCPA). A espirometria foi realizada com espirômetro computadorizado e o teste de apneia respiratória utilizando-se um sistema eletrônico microprocessado e um pneumotacógrafo ((Hans Rudolph ® – Kansas OH, EUA)– Kansas OH, EUA) como transdutor de fluxo. As curvas de fluxo respiratório foram exibidas em tempo real em um computador portátil e os tempos máximos de apneia voluntária inspiratória e expiratória (TAVIM e TAVEM) foram determinados a partir do sinal adquirido. Resultados: Um total de 35 pacientes com DVO (casos) e 16 controles foram incluídos no estudo. O TAVIM foi significativamente menor nos casos (22,3 ± 11,8 s) do que no grupo controle (31,5 ± 15,7 s) com p = 0,025. O TAVEM também foi significativamente menor nos casos (16,9 ± 6,6 s) do que no grupo controle (22,1 ± 7,9 s) com p = 0,017. Foram encontradas correlações positivas moderadas entre TAVIM e CVF (r = 0,476, p = 0,004) e entre TAVIM e VEF1 (r = 0,383, p = 0,023). Conclusões: As medidas de TAVIM e TAVEM foram significativamente menores nos casos do que nos controles, e o TAVIM teve correlação moderada com a CVF e VEF1. Estes resultados fornecem uma evidência adicional da utilidade clínica do tempo de apneia como teste de função pulmonar. / Introduction: Breath-holding test has been tested in some clinical scenarios and has proved to be of clinical utility. Objectives: To determine the maximum voluntary breath-holding time in patients with obstructive ventilator defects and in normal subjects and to correlate the breathholding times with pulmonary function tests. Methods: We conducted a case-control study including patients with obstructive ventilator defects and a control group consisted of volunteers recruited in the same hospital, with normal spirometry. Spirometry was performed using a computerized spirometer. The Breath-holding test was conducted using an electronic microprocessor and a (Hans Rudolph ® – Kansas OH, EUA)pneumotachograph and flow transducer. Respiratory flow curves were displayed in real time on a portable computer. The maximal voluntary apnea inspiratory and expiratory times (MVAIT and MVAET) were determined from the acquired signal. Results: A total of 35 patients with obstructive ventilatory defects and 16 controls met the inclusion criteria and were included in the analysis. The MVAIT was lower in cases (22.3 ± 11.8 seconds) than in controls (31.5 ± 15.7 seconds) (p=0.025). MVAET was also lower in cases than in controls (16.9 ± 6.6 vs. 22.1 ± 7.9; p=0.017). We found positive and significant correlations between MVAIT and FVC (L) (r=0.476; p=0.004) and between MVAIT and FEV1 (L) (r=0.383; p=0.023). Conclusions: MVAIT and MVAET were significant lower in patients with obstructive ventilatory defects than in controls, and that MVAIT was correlated positively with FVC and FEV1 in cases. Our results provide additional evidence of usefulness of MVAIT as a pulmonary function test.
107

Prevalência de infecção de sítio cirúrgico em pacientes adultos num hospital geral do interior paulista / Prevalence of surgical site infection among adult patients in a general hospital in the interior of São Paulo

Fabrício Ribeiro de Campos 22 August 2016 (has links)
Introdução: As Infecções Relacionadas à Assistência á Saúde (IRAS) são consideradas um problema de saúde pública com implicações sociais e econômicas graves que geram sobrecarga nas instituições de saúde, aumentando o período de internação e elevando consideravelmente a morbimortalidade em pacientes hospitalizados. A infecção do sítio cirúrgico (ISC) se constitui como uma das mais temidas complicações decorrentes dos procedimentos cirúrgicos No Brasil, são escassos os estudos epidemiológicos sobre as infecções em pacientes submetidos à procedimentos anestésico cirúrgico. Objetivo: Identificar a prevalência de infecção de sítio cirúrgico em pacientes adultos submetidos à cirurgia num hospital geral privado filantrópico, de nível terciário do interior paulista, segundo o potencial de contaminação da ferida operatória. Materiais e Métodos: Trata-se de um estudo de corte transversal, com abordagem retrospectiva e quantitativa, aprovado pelo Comitê de Ética em Pesquisa da Escola de Enfermagem de Ribeirão Preto da Universidade de São Paulo. A população do estudo foi constituída 58 prontuários médicos de pacientes submetidos à cirurgia no referido hospital exceto nas especialidades de ortopedia e ginecologia, no período de janeiro de 2014 a dezembro de 2014 e que apresentaram infecção do sítio cirúrgico. Os dados foram coletados por meio de consulta aos prontuários e analisados por meio de estatística descritiva utilizando-se o programa Statistical Package for the Social Sciences, version 17.0 para Windows. Resultados: A taxa global de infecção do sítio cirúrgico foi de 1,9% (57/3.064), as especialidades com maiores taxas foram a neurocirurgia (3,5%), seguida pela cirurgia geral (2,0%). Ao se analisar a taxa de infecção por potencial de contaminação, nas cirurgias limpas foi de 1,0%, nas potencialmente contaminadas 1,8%, nas contaminadas 5,4% e nas infectadas 7,2%. Nas cirurgias limpas a maior taxa foi na neurocirurgia, na potencialmente contaminada foi na cirurgia torácica, na contaminada e infectada foi na cirurgia geral. E ressalta-se que 46,6% tiveram infecção de órgão ou cavidade. Conclusão: O presente estudo permitiu identificar as taxas globais de infecção do sítio cirúrgico e também, por especialidades e por potencial de contaminação, dados esses que podem contribuir para o planejamento das ações de prevenção e controle de Infecção do sítio cirúrgico no referido hospital / Introduction: Healthcare-associated infections (HAI) are considered to be a public health problem with serious social and economic implications that overload health institutions, extend hospital length of stay and considerably increase morbidity- mortality among hospitalized patients. Surgical site infections (SSI) are one of the most feared complications from surgical procedures. There are few epidemiological studies in Brazil on infections among patients submitted to anesthetic-surgical procedures. Objective: To identify the prevalence of surgical site infection among adult patients submitted to surgery in a tertiary philantropic private general hospital in the interior of the state of São Paulo, according to the potential of contamination of the operative wound. Materials and Methods: This is a cross-sectional study, using a retrospective and quantitative approach, approved by the Research Ethics Committee of the Ribeirão Preto College of Nursing, at the University of São Paulo. The study sample was made up of 58 medical records of patients submitted to surgery in this hospital, except for the orthopedics and gynecology specialties, from January to December 2014, who presented surgical site infection. Data were collected from the medical records and analyzed by means of descriptive statistics, using the Statistical Package for the Social Sciences software, version 17.0 for Windows. Results: Overall surgical site infection rate was 1.9% (57/3,064), and specialties with higher rates were neurosurgery (3.5%) and general surgery (2.0%). Regarding the infection rate by potential contamination, in clean surgeries it was 1.0%; in potentially contaminated surgeries, it was 1.8%; in contaminated surgeries, it was 5.4%; and in infected surgeries, it was 7.2%. Neurosurgery presented the highest rate in clean surgeries; thoracic surgery in potentially contaminated surgeries; whereas general surgery had the highest rate in contaminated and infected surgeries. It is worth highlighting that 46.6% reported organ or cavity infection. Conclusion: This study allowed to identify overall rates of surgical site infection, also by specialty and potential of contamination. These data can contribute to the planning of actions to prevent and control surgical site infection in the studied hospital
108

Influência da exérese da cápsula de Tenon na cirurgia de implante de Ahmed com uso da mitomicina C em portadores de glaucoma neovascular / Partial Tenon´s capsule resection with adjunctive mitomycin C in Ahmed valve implant surgery among neovascular glaucoma patients

Jair Giampani Junior 15 October 2004 (has links)
Este estudo teve por objetivo avaliar a eficácia e a segurança da cirurgia de implante de Ahmed, associada à ressecção parcial da cápsula de Tenon e ao uso da mitomicina C, em portadores de glaucoma neovascular. A amostra foi constituída por 31 olhos de trinta pacientes portadores de glaucoma neovascular, secundário à retinopatia diabética proliferativa ou à oclusão da veia central da retina, com acuidade visual maior ou igual à percepção luminosa. Os olhos foram randomizados para formarem dois grupos: implante de Ahmed convencional, associado ao uso da mitomicina C (n=15), e implante de Ahmed de alta resistência, associado à ressecção parcial da cápsula de Tenon e ao uso da mitomicina C (n=16). Controlaram-se as variáveis procurando homogeneizar os grupos a fim de prevenir vieses nas avaliações dos desfechos. Definiram-se como sucesso cirúrgico simples os casos com pressões oculares maiores ou iguais a 5 mm Hg e menores ou iguais a 21 mm Hg. A média de idade foi de 58,06 anos ± 13,02 , sendo de 62,63 anos ± 10,23 no grupo com e de 53,20 anos ± 14,22 no grupo sem ressecção parcial da cápsula de Tenon (p = 0,109). Não houve diferença estatisticamente significativa entre os grupos com relação ao sexo (p = 0,722), olho operado (p = 1,0), causa do glaucoma neovascular (p = 1,0), existência de panfotocoagulação prévia (p = 1,0) e acuidade visual pré-operatória (p = 0,154). A pressão ocular média pré-operatória foi de 51,00 ± 10,05 mm Hg no grupo com ressecção parcial da cápsula de Tenon e de 51,20 ± 11,58 mm Hg no grupo sem ressecção da cápsula de Tenon (p = 0,889). Houve redução significativa da pressão ocular em ambos os grupos a partir do primeiro dia do pós-operatório. A pressão ocular média dos grupos com e sem ressecção parcial da cápsula de Tenon aos 24 meses de seguimento foi de, respectivamente, 17,00 ± 12,77 mm Hg e 19,78 ± 15,71 mm Hg (p = 0,820). O seguimento médio foi de 23,44 meses ± 9,63 no grupo com ressecção parcial da cápsula de Tenon e de 23,40 meses ± 9,62 no grupo sem ressecção parcial da cápsula de Tenon (p = 0,952). Registraram-se diferenças estatisticamente significativas entre as pressões médias nos grupos com e sem ressecção parcial da cápsula de Tenon apenas no primeiro dia, terceiro e sétimo meses do pós-operatório. Houve redução mais intensa da acuidade visual no grupo sem ressecção parcial da cápsula de Tenon do que no grupo com exérese da cápsula de Tenon (p = 0,023*). O sucesso simples foi de 62,5% (dez olhos) no grupo com e de 53,3% (oito olhos) no grupo sem ressecção parcial da cápsula de Tenon (p = 0,722). Não se verificaram bolhas transparentes, pálidas ou isquêmicas em fase alguma do pós-operatório, em ambos os grupos. As freqüências das complicações foram semelhantes em ambos os grupos, exceto por uma freqüência quase quatro vezes maior de exposição do implante no grupo com ressecção parcial da cápsula de Tenon. Em resumo, os índices de sucesso cirúrgico foram semelhantes entre os grupos com e sem ressecção parcial da cápsula de Tenon, após um seguimento médio de 23,42 meses. Houve redução significativa da acuidade visual nos dois grupos, a qual foi mais intensa naquele sem ressecção parcial da cápsula de Tenon. A exposição do implante de drenagem foi quase quatro vezes mais freqüente no grupo submetido à ressecção parcial da cápsula de Tenon / The objective of the study was to evaluate the safety and efficacy of Ahmed glaucoma valve implant surgery combined with partial Tenon\'s capsule resection and mitomycin C administration in neovascular glaucoma patients. Our sample comprised 31 eyes of 30 patients with neovascular glaucoma secondary to proliferative diabetic retinopathy or central retinal vein occlusion. The 30 patients all had visual acuity equal to or greater than their perception of light. The eyes were randomized into two groups: conventional Ahmed valve implant combined with mitomycin C administration (n = 15); and high-resistance Ahmed implant combined with partial Tenon\'s capsule resection and mitomycin C administration (n = 16). Variables were controlled in an attempt to homogenize the groups and thereby avoid any bias in the evaluation of the results. Simple surgical success was defined as ocular pressure equal to or greater than 5 mmHg but less than or equal to 21 mmHg. Median age was 58.06 ± 13.02 (53.20 ± 14.22 in the group not submitted to resection and 62.63 ± 10.23 in the group submitted to partial Tenon\'s capsule resection; p = 0.109). No statistically significant difference between the groups was found related to gender (p = 0.722), operated eye (p = 1.0), cause of neovascular glaucoma (p = 1.0), previous panphotocoagulation (p = 1.0), or preoperative visual acuity (p = 0.154). Mean preoperative ocular pressure was 51.20 ± 11.58 mmHg in the group not submitted to resection and 51 ± 10.05 mmHg in the group submitted to partial Tenon\'s capsule resection (p = 0.889). From the first preoperative day, there was a significant reduction in ocular pressure in both groups. At 24 months after surgery, mean ocular pressure of subjects not submitted and submitted to partial Tenon\'s capsule resection was 19.78 ± 15.71 mmHg and 17.00 ± 12.77 mmHg, respectively (p = 0.820). Mean length of the follow-up period was 23.40 ± 9.62 months in those not submitted to resection and 23.44 ± 9.63 months in the group submitted to partial Tenon\'s capsule resection (p = 0.952). Statistically significant differences in ocular pressure were found between the two groups only on postoperative day 1 and at 3 and 7 months after surgery. In the group not submitted to resection, there was a more marked reduction in visual acuity (p = 0.023*). Simple surgical success was achieved in 53.3% (8) of the eyes in the group not submitted to resection and in 62.5% (10) of the eyes in the group submitted to partial Tenon\'s capsule resection (p = 0.722). There were no pale or transparent blebs in either group during the postoperative phase. The incidence of complications was similar between the two groups, with the exception of the incidence of implant tube exposure, which was four times greater in the group submitted to partial Tenon\'s capsule resection. In conclusion, after a mean follow-up period of 23.42 months, the measures of surgical success were comparable between the two groups. There was significant reduction in visual acuity in both groups, more markedly in the group not submitted to resection. The implant drainage tube became exposed four times more frequently in the group submitted to partial Tenon\'s capsule resection
109

Avaliação de parâmetros de coagulação e viscosidade plasmática após sobrecarga lipídica / Evaluation of coagulation parameters and plasmatic viscosity after lipid overload

Peres, Gabriel [UNESP] 14 December 2016 (has links)
Submitted by GABRIEL PERES (gabrielperes@uol.com.br) on 2017-01-12T17:59:41Z No. of bitstreams: 1 Dissertacao_Gabriel_Peres__MEPAREM - final_PG.pdf: 1188057 bytes, checksum: 3d743000ee2199b4bada7a4a8ceff65e (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-01-16T16:15:03Z (GMT) No. of bitstreams: 1 peres_g_me_bot.pdf: 1188057 bytes, checksum: 3d743000ee2199b4bada7a4a8ceff65e (MD5) / Made available in DSpace on 2017-01-16T16:15:03Z (GMT). No. of bitstreams: 1 peres_g_me_bot.pdf: 1188057 bytes, checksum: 3d743000ee2199b4bada7a4a8ceff65e (MD5) Previous issue date: 2016-12-14 / Outra / Fundamentos: Diversos estudos realizados visam a prevenção de complicações em cirurgia dermatológica, dentre as quais o sangramento. Trabalhos anteriores demonstraram que uma dieta com sobrecarga lipídica poderia influenciar o padrão coagulatório, reduzindo o sangramento cirúrgico. Este trabalho visa avaliar o efeito da sobrecarga lipídica nos parâmetros laboratoriais de coagulação e sangramento. Casuística e métodos: Dez indivíduos coletaram amostras de sangue em jejum e após trinta minutos da ingestão de sorvete (21g de gordura). Procederam-se exames: hemograma, tempo de sangramento, TTPA, TP, VHS, viscosidade plasmática e perfil lipídico. Os dados foram tabulados e analisados (teste t de Student para amostras dependentes ou Wilcoxon). Considerou-se significativo p<0,05. Resultados: Houve alteração no perfil lipídico (p<0,05): colesterol total (média: 190,3 para 194,4), VLDL (mediana: 19,5 para 21,0) e triglicerídeos (mediana: 101,5 para 105,0), porém, sem alteração significativa das frações LDL e HDL. A contagem de plaquetas apresentou diminuição (média: 243,2 mil para 232,1 mil; p<0,05), entretanto, sem alterações significativas no coagulograma, hemossedimentação e viscosidade sanguínea. Conclusão: A modificação no perfil lipídico indicou adequada absorção da gordura, todavia, não se demonstrou, sob os parâmetros laboratoriais avaliados, e o protocolo empregado, evidências de que a sobrecarga lipídica por via oral promova alterações coagulatórias ou de viscosidade sanguínea. / Background: Several studies have already been performed for the prevention of complications in dermatologic surgery, including bleeding. Previous researches have shown that a diet with fat overload could influence the pattern of coagulation and repair mechanisms, reducing surgical bleeding. This study aims to evaluate the effect of a lipid overload in the parameters of coagulation and bleeding. Patients and Methods: Blood samples were performed in ten individuals, collected on fasting and thirty minutes after eating ice cream (21g of fat). Held up tests: blood count, bleeding time, aPTT, PT, ESR, plasma viscosity and lipid profile. The data were tabulated and analyzed (Student t test for dependent samples or Wilcoxon). A significant p<0,05 was considered. Results: There was an increase in lipid profile (p<0,05): total cholesterol (mean: 190,3 to 194,4), VLDL (median: 19,5 to 21,0) and triglycerides (median: 101,5 to 105,0), but no significant changes on LDL and HDL fractions. The platelet count also showed a decrease (mean: 243200 to 232100; p < 0,05), however, no significant changes in coagulation, erythrocyte sedimentation rate and blood viscosity. Conclusion: The increase in lipid profile indicated adequate absorption of fat, however, not shown, under these laboratory parameters with the chosen protocol, evidences that an orally fat overload is able to modify coagulation or blood viscosity. / FUNADERSP (RESP-SBD): 28/06/2016
110

Morbimortalidade relacionada à disfunção renal aguda estimada pelo critério pRIFLE em crianças submetidas a cirurgia cardíaca

El Halal, Michel Georges dos Santos January 2012 (has links)
Objetivos: O objetivo deste estudo foi investigar associação entre ocorrência de disfunção renal aguda de acordo com o critério RIFLE pediátrico (pRIFLE) e desfechos negativos em crianças em pós-operatório de cirurgia cardíaca. Métodos: Crianças submetidas à cirurgia cardíaca em um hospital terciário no sul do Brasil foram acompanhadas da internação até a alta da Unidade de Terapia Intensiva Pediátrica (UTIP) ou óbito. A variável de exposição foi ocorrência de disfunção renal aguda de acordo com o critério pRIFLE, que divide disfunção renal aguda em 3 categorias: R-Risco, I-Lesão, F-Insuficiência. Os desfechos estudados foram morte, tempo de ventilação mecânica (VM) e tempo de internação na UTIP. Resultados: Oitenta e cinco crianças foram estudadas. Quarenta e sete (55,3%) não desenvolveram disfunção renal aguda durante a internação na UTIP, enquanto que 22 (25,9%), 7 (8,2%) e 9 (10,6%) foram classificadas nos grupos R, I, e F, respectivamente. A incidência de óbito foi de 18,4% e de 4,2% nos pacientes com e sem disfunção renal aguda, respectivamente. Comparado a crianças que não desenvolveram disfunção renal, a razão de chances ajustada de óbito foi 1,046 (0,09-11,11), 8,358 (1,32-52,63) e 7,855 (1,53-40,29) nos grupos R, I, e F, respectivamente (p = 0,022). Os tempos de VM e de internação na UTIP foram significativamente maiores nas crianças com disfunção renal aguda. Conclusões: Ocorrência de disfunção renal aguda de acordo com o critério pRIFLE está associado com maior morbidade (maior tempo de VM e de internação na UTIP) e maior mortalidade em crianças em pós-operatório de cirurgia cardíaca. / Objectives: This study aims to investigate association between occurrence of acute kidney injury (AKI) according to pediatric RIFLE (pRIFLE) criteria and adverse outcomes in children after heart surgery. Methods: Children submitted to open heart surgery in a tertiary hospital in Southern Brazil were followed from arrival until discharge from the Pediatric Intensive care Unit (PICU) or death. The exposition variable was occurrence of AKI according to pRIFLE criteria, which divides AKI in three categories: R-Risk, I-Injury, F-Failure. The outcomes studied were death, length of mechanical ventilation (MV) and length of PICU stay. Results: Eighty five children were studied. Forty seven (55.3%) did not have AKI during PICU stay, while 22 (25.9%), 7 (8.2%) and 9 (10.6%) were classified as R, I and F, respectively. The incidence of death was 18.4% and 4.2% in patients with and without AKI, respectively. Comparing to children who did not develop AKI, the adjusted odds ratio for death was 1.046 (0.09-11.11), 8.358 (1.32-52.63) and 7.855 (1.53-40.29) in the R, I and F group, respectively (p = 0.022). Lengths of MV and of PICU stay were significantly higher in those with AKI. Conclusions: Occurrence of AKI according to pRIFLE criteria is associated to adverse outcomes in children after open heart surgery.

Page generated in 0.051 seconds