Spelling suggestions: "subject:"créé natal"" "subject:"crée natal""
501 |
Avaliação da testagem anti-HIV no pré-natal e parto e fatores associados à submissão ao teste rápido anti-HIV em maternidades do município do Rio de JaneiroGomes, Daniela Marcondes January 2015 (has links)
Submitted by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-10-20T14:44:11Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
DISSERTAÇAO DANIELA GOMES.pdf: 822633 bytes, checksum: 1fcb3aa715324aad065253a1af0b4571 (MD5) / Approved for entry into archive by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-10-20T14:44:21Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
DISSERTAÇAO DANIELA GOMES.pdf: 822633 bytes, checksum: 1fcb3aa715324aad065253a1af0b4571 (MD5) / Made available in DSpace on 2017-10-20T14:44:21Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
DISSERTAÇAO DANIELA GOMES.pdf: 822633 bytes, checksum: 1fcb3aa715324aad065253a1af0b4571 (MD5)
Previous issue date: 2015 / Universidade Iguaçú. Docente / Introdução: Com vistas à prevenção da transmissão vertical, o Ministério da Saúde preconiza que as mulheres sejam testadas para o HIV na gestação, e que na admissão para o parto seja oferecido o teste rápido anti-HIV para todas as gestantes não testadas para HIV no pré-natal ou sem resultado disponível. O objetivo deste estudo foi avaliar a testagem anti-HIV durante a assistência pré-natal e a internação para o parto, e analisar os fatores associados à submissão ao teste rápido anti-HIV. MÉTODOS: Estudo transversal conduzido no segundo semestre de 2009 nas 15 maternidades do município do Rio de Janeiro com mais de 1000 partos/ano, por meio de entrevistas realizadas com amostra representativa de 835 mães e observação de prontuários. Para avaliação da testagem anti-HIV foi elaborado um modelo teórico lógico. Na análise dos fatores associados à submissão ao teste rápido anti-HIV (desfecho), razões de prevalência ajustadas (p≤ 0,05) foram obtidas por modelo de regressão de Poisson com variância robusta, segundo modelo hierarquizado. RESULTADOS: Segundo as mães, 86,7% dispunham de sorologia negativa do pré-natal e 55,7% foram submetidas ao teste rápido anti-HIV no hospital. Segundo dados do prontuário, 68,0% dispunham de sorologia negativa do pré-natal e 79,6% foram submetidas ao teste rápido anti-HIV. O procedimento relativo ao teste rápido anti-HIV no hospital foi considerado adequado (mães com status ignorado de HIV do pré-natal submetidas ao teste rápido e mães com status conhecido não submetidas) em 49,9% das mulheres, segundo os dados maternos, e em 50,9% das mulheres, segundo dados do prontuário. Na análise múltipla a cor da pele não branca (RP=1,155) se associou a uma maior prevalência do desfecho, enquanto a baixa escolaridade materna (RP=0,856) esteve associada a uma menor prevalência do mesmo. A não realização de pré-natal (RP=1,289), não dispor de sorologia negativa de exame anti-HIV do pré-natal (RP=1,226) e a ocorrência de parto em hospital não certificado como amigo da criança (RP=1,286) se mostraram associados a uma maior prevalência de testagem rápida anti-HIV no hospital. CONCLUSÕES: Os protocolos de testagem anti-HIV não vêm sendo cumpridos a contento. A gama de fatores associados à submissão ao teste rápido anti-HIV compreendeu não apenas os preconizados, como a ausência de sorologia negativa do pré-natal, como também características sociodemográficas e a não certificação do hospital como amigo da criança. Recomenda-se a qualificação da equipe de saúde envolvida na assistência à gestante, para que a sorologia anti-HIV seja solicitada quando procedente, e seja ágil o processo de entrega dos resultados, com vistas à efetividade das ações de controle da transmissão vertical / Introduction: In order to prevent vertical transmission, the Brazilian Ministry of Health recommends women to be tested for HIV during pregnancy, and to be offered the HIV rapid test on admission for delivery to all pregnant women not tested for HIV during prenatal care or with no result available. The purpose of this study was to evaluate HIV testing during prenatal care and hospitalization for childbirth, and to identify factors associated with submission to the HIV rapid test. METHODS: Cross-sectional study conducted in the second half of 2009 in 15 hospitals in Rio de Janeiro City with more than 1000 deliveries / year, through interviews with a representative sample of 835 mothers and observation of records. A logical theoretical model was elaborated to assess anti-HIV testing. To analyze factors associated with submission to HIV rapid test, adjusted prevalence ratios (p ≤ 0.05) were obtained by Poisson regression model with robust variance, by means of a hierarchical model. RESULTS: According to the mothers, 86.7% underwent HIV testing during prenatal care with a negative serology and 55.7% were submitted to the rapid HIV test in the hospital. According to the records, 68.0% had a negative serology from prenatal care and 79.6% were submitted to the rapid HIV test. The HIV rapid testing at the hospital was considered adequate (mothers with unknown HIV status submitted to the rapid test and mothers with known status not submitted) in 49.9% of the women, according to maternal data, and in 50.9% of the women, according to medical records. In multiple analysis maternal non-white skin color (PR = 1.155) was associated with a higher prevalence of the outcome, while low maternal education (PR = 0.856) was associated with a lower prevalence. Not performing prenatal care (RP = 1.289), not having a negative serology from prenatal care (RP = 1.226) and delivery in a hospital non certified as Baby-Friendly (RP = 1.286) were associated with a higher prevalence of being submitted to the HIV rapid test in the hospital. CONCLUSIONS: HIV testing protocols are not being met satisfactorily. The range of factors associated with submission to the HIV rapid test comprised not only the recommended, as the absence of negative serology from prenatal care, but also sociodemographic characteristics and delivery at non Baby-Friendly Hospital. Qualification of health staff involved with pregnant women care is recommended, so that HIV testing is required when appropriate and the delivery of the results are agile, in order to improve the effectiveness of vertical transmission control measures
|
502 |
Consumo alimentar de ácidos graxos em gestantes com insuficiência placentária / Food intake of fatty acids in pregnant women with placental insufficiencySaffioti, Renata Felipe 12 March 2014 (has links)
Objetivo: analisar o consumo alimentar de energia, macronutrientes e ácidos graxos, de gestantes com insuficiência placentária, comparando com gestantes sem esta complicação obstétrica. Métodos: Estudo prospectivo, transversal e caso-controle realizado no período de fevereiro de 2012 a setembro de 2013, que incluiu gestantes que preencheram os seguintes critérios: gestação com feto único e vivo; idade gestacional superior a 26 semanas completas; diagnóstico de insuficiência placentária caracterizada pelo exame de Doppler de artéria umbilical com índice de pulsatilidade acima do p95; morfologia fetal normal ao exame de ultrassonografia; ausência de diagnóstico de diabetes; não suplementação pré-natal com ácidos graxos. Foram adotados os seguintes critérios de exclusão: diagnóstico pós-natal de anomalia do recém-nascido. O estado nutricional da gestante foi avaliado pelo índice de massa corporal (IMC) e o consumo dietético foi investigado pela aplicação do questionário de frequência alimentar, analisado pelo programa Avanutri Revolution versão 4.0, pelo qual se obteve o consumo de energia, macronutrientes (carboidratos, proteínas e lipídios) e de ácidos graxos (saturados, poli-insaturados e monoinsaturados). Foram analisados os valores absolutos obtidos e a % do valor energético total (VET) da dieta. Resultados: Foram incluídas 21 gestantes no grupo com insuficiência placentária e 21 gestantes no grupo controle. Não se constatou diferença na mediana do IMC na comparação entre os grupos (grupo estudo=26,5 kg/m2, grupo controle=28,0kg/m2; P=0,563). Houve diferença significativa na comparação do grupo com insuficiência placentária com o grupo controle na análise do consumo alimentar de: energia (2002 kcal vs. 1515 kcal, p= 0,021). Com relação ao consumo de ácidos graxos, houve diferença significativa na comparação da % do VET entre os grupos com insuficiência placentária e controle: saturados (11,5% vs. 9,3%; p=0,043); poli saturados (2,7% vs. 3,6%; p=0,029); monoinsaturados (1,2 % vs. 2,1%; p= 0,005). Não foram encontradas diferenças significativas na qualidade da dieta entre os grupos quanto ao consumo avaliado de acordo com a % do VET: carboidratos (51,5% vs. 51,8%; p= 0,831); proteínas (15,3% vs. 16,1%; p= 0,458); lipídios totais (37,8% vs. 33,0%; p=0,831). Conclusão: Gestantes com o diagnóstico de insuficiência placentária relatam consumo alimentar diferente de gestantes que não apresentam esse diagnóstico, com dieta de ácidos graxos com qualidade inferior, notadamente com maior consumo de ácidos graxos saturados, e menor consumo de poli-insaturados e monoinsaturados, além de maior consumo de energia / Objective: To analyze the dietary intake of energy, macronutrients and fatty acids of pregnant women with placental insufficiency, and to compare with pregnant women without this obstetric complication Methods : A prospective, cross-sectional and case -control study from February 2012 to September 2013, which included women who met the following criteria: singleton pregnancy with fetus alive; above 26 weeks gestation; diagnosis of placental insufficiency characterized by umbilical artery Doppler presenting pulsatility index above the p95; normal fetal morphology at ultrasound, absence of diabetes, absence of prenatal supplementation with fatty acids. We used the following exclusion criteria: neonatal diagnosis of malformation. The maternal nutritional status was assessed by body mass index (BMI) and dietary intake was investigated by applying the food frequency questionnaire analyzed by the program Avanutri Revolution version 4.0 , which was obtained by the consumption of energy, macronutrients (carbohydrates, proteins and lipids) and fatty acids (saturated, polyunsaturated and monounsaturated). We analyzed the absolute values and the % of total energy value (TEV). Results: We included 21 pregnant women in the study group with placental insufficiency and 21 pregnant women in the control group. There was no difference in median BMI between the groups (study group = 26.5 kg/m2, control group = 28.0 kg/m2, P = 0.563). Significant difference was found when the group with placental insufficiency was compared with the control group in food consumption of energy (2002kcal vs. 1515 kcal, p = 0.021). With regard to the consumption of fatty acids, there was a significant difference in the percentages of daily energy intake between the group with placental insufficiency and control group: saturated fatty acids(11.5% vs. . 9.3% , p = 0.043), polyunsaturated fatty acids(2.7 % vs. 3.6% , p = 0.029), monounsaturated fatty acids(1.2% vs. 2.1% , p = 0.005). There were no significant differences in diet quality between the groups regarding the consumption evaluated according to the % of VET: carbohydrates ( 51.5 % vs. 51.8 %, p = 0.831 ), protein (15.3 % vs. 16.1 %, p = 0.458), total fat (37.8 % vs. 33.0 %, p = 0.831) . Conclusion: Pregnant women with the diagnosis of placental insufficiency reported food consumption other than pregnant women who do not have this diagnosis with lower quality of dietary fatty acids consumption, especially with higher intake of saturated fatty acids , and lower intake of polyunsaturated and monounsaturated fatty acids, and greater energy consumption
|
503 |
Rubéola na gestação: repercussões sobre o produto conceptual. / Rubella in pregnancy: effects on the fetus and developing childPedreira, Denise Araujo Lapa 02 December 1998 (has links)
OBJETIVOS: Avaliar os efeitos da rubéola durante a gestação, sobre o feto, o recém-nascido e a criança. CASUÍSTICA E MÉTODO: Analisamos 35 gestantes com suspeita de rubéola que foram divididas em dois grupos. Grupo 1: 15 pacientes que apresentaram quadro clínico com comprovação sorológica. Grupo2: 20 pacientes com IgM positiva na rotina pré-natal, na ausência de quadro clínico. O seguimento ultrasonográfico mensal foi realizado em todas as pacientes e as do grupo 1 foram encaminhadas também para propedêutica invasiva. Foram também realizadas a ecocardiografia fetal e a Dopplervelocimetria. As placentas foram submetidas a exame anátomo-patológico. Os recém-nascidos vivos foram avaliados através de exame clínico e sorológico, além do potencial evocado auditivo, ultra-sonografia de crânio, fundo de olho e ecocardiografia pós-natal. RESULTADOS: No grupo 1: a infecção fetal ocorreu em 9 casos, sendo que o risco de transmissão vertical entre 2 a 14 semanas foi de 64,9%. A malformação ocorreu em 37,5% dos infectados. A ultrasonografia revelou crescimento intra-uterino retardado simétrico em todos os fetos infectados que atingiram o terceiro trimestre, tendo se iniciado, em média com 25,1 semanas. A cordocentese foi realizada em 9 pacientes e, todos os casos infectados, apresentavam IgM positiva e eritroblastose no sangue de cordão. A PCR no líquido amniótico foi positiva em todos os 3 casos em que ela foi realizada. 50% das placentas dos fetos infectados apresentava sinais sugestivos de infecção viral. A idade gestacional média do parto entre os infectados foi de 33,8 semanas e o peso médio ao nascimento foi 1365,6g.Todos os 6 nascidos-vivos infectados foram classificados como pequenos para a idade gestacional e apresentaram disacusia. A sobrevida entre os infectados, num seguimento pós-natal médio de 35,2 meses, foi de 62,5%. No grupo 2: a infecção não foi comprovada em nenhum dos recém-nascidos vivos, porém em um caso pudemos demonstrar a infecção congênita pelo vírus de Epstein-Barr. CONCLUSÕES: A transmissão vertical da rubéola no primeiro trimestre parece poder variar entre as populações, bem como a presença dos defeitos associados à infecção. Tanto o diagnóstico invasivo, como o ultrasonográfico apresentaram boa sensibilidade e especificidade. Pudemos estabelecer o padrão de crescimento fetal associado à infecção. A presença isolada de IgM positiva para rubéola na gestação não teve boa correlação com a presença de infecção neonatal, porém pode se associar à presença de outras infecções congênitas. / OBJECTIVES: Our aim was to analyse rubella effects on the fetus, new-born and child. MATERIAL AND METHODS: We analysed 35 patients with suspicious rubella during pregnancy. According to presence or absence of symptoms they were divided in two groups. Group 1: 15 patients presenting rash in which serology was positive. Grupo2: 20 symptomless patients found to have positive IgM during routine prenatal care. Monthly ultrasonographic evaluation was accomplished in all patients and in group 1 they were also offered prenatal invasive testing. Fetal echocardiography and Dopplers were performed. After birth, the placentas were submitted to pathological examination. The liveborn babies had clinical and serological examination. Auditory tests, brain scan, fundoscopy and postnatal echocardiography were also performed. RESULTS: In group 1: fetal infection occurred in 9 cases and vertical transmission between 2 to 14 weeks was 64,9%. Malformation was present in 37,5% of infected cases. Ultrasound revealed symmetrical intra-uterine growth retardation in all infected fetuses that reached the third trimester, and started around 25,1 weeks. Cordocentesis was accomplished in 9 cases and all the infected ones, presented positive IgM and erythroblastosis in cord blood. PCR in the amniotic fluid was positive in all 3 cases it was performed. 50% of the infected fetuses placentas presented signs of viral infection. The average gestacional age of delivery among infected cases was 33,8 weeks and medium birth weight was 1365,6g. All 6 liveborn infected babies were small for gestacional age and presented deafness. Survival among infected cases was 62,5%, medium follow-up was 35,2 months. In group 2: the infection was not demonstrated in any of neonates, although we could demonstrate a congenital infection caused by the Epstein-Barr virus. CONCLUSIONS: Vertical transmission of the rubella in the first trimester seems to vary among different populations, as well as the presence of the associated defects in the new-born. Invasive diagnosis and ultrasonographic follow-up presented good sensitivity and specificity. We could establish the pattern of fetal grown associated to the infection. The isolated presence of a positive rubella IgM in pregnancy did not correlated with congenital rubella, but it can be related to other congenital infections.
|
504 |
Estudo do volume pulmonar fetal na predição da morbidade neonatal em pacientes com lesão pulmonar congênita / Ultrasound assessment of fetal lung volume for prediction of neonatal morbidity in congenital lung malformationFreitas, Rogério Caixeta Moraes de 10 August 2016 (has links)
Introdução: A maioria dos fetos com lesão pulmonar congênita (LPC) são assintomáticos e apresentam baixa morbidade ao nascimento. No entanto, alguns neonatos apresentam desconforto respiratório e necessitam receber de cuidados especiais neste período. Decidir quais casos com LPC precisam nascer em um centro de referência é um desafio. Objetivo: O objetivo deste estudo foi predizer a morbidade neonatal em fetos com LCP sem hidropisia avaliados pela ultrassonografia tridimensional (US3D). Método: Estudo observacional, entre janeiro de 2005 e janeiro de 2016, com fetos com LPC e sem hidropisia. Os volumes pulmonares foram mensurados pela US3D, técnica VOCAL, em dois períodos: entre 20 e 28 semanas (1o momento) e entre 29 e 34 semanas (2o momento). A variação intra e inter-operador foi analisada para os volumes pulmonares. As relações volumétricas testadas foram: volume pulmonar observado / esperado (VPTo/e); volume da lesão pulmonar / circunferência cefálica (LVR) e volume da lesão / volume pulmonar observado (VL/VPTo). As relações volumétricas foram usadas na predição da morbidade neonatal (admissão em unidade de terapia intensiva neonatal (UTI), necessidade de intubação (IOT); necessidade de cirurgia no período neonatal por sintomatologia respiratória). Regressão logística múltipla e curva ROC foram aplicadas para determinar a acurácia na predição dos resultados. Resultados: Dos 45 fetos não hidrópicos com LPC incluídos no estudo, 18 (40%) foram admitidos na UTI, 14 (31,1%) necessitaram de IOT, e sete (15,6%) cirurgia neonatal. A variação intra e inter-operador para os volumes pulmonares apresentou boa reprodutibilidade e não houve diferença estatística (p > 0,05). No 1o momento (IG: 20 - 28 semanas) observou-se que todas as relações volumétricas (1oVPTo/e, 1oLVR e 1oVL/VPTo) foram preditoras para admissão na UTI e necessidade de IOT. No 2o momento (IG: 29 - 34 semanas), apenas o 2oVPTo/e, e, 2oVL/VPTo foram preditores para IOT. Nenhuma das razões volumétricas (VPTo/e, LVR e VL/VPTo) foram preditoras para a cirurgia neonatal. No 1º momento, o melhor preditor para UTI foi 1º VPTo/e (ASC 0,86; p < 0,001) e para IOT foi 1º VL/VPTo (ASC 0,94; p < 0,001). Os cut-off escolhidos para a admissão na UTI foi 1º VPTo/e<0,53 (s:91,7%; e:70,8%; a:77,8%); e para IOT foi 1º VL/VPTo > 1,18 (s:91,7%; e:62,5%, a:72%). Para o 2o momento, a melhor relação volumétrica preditora para admissão na UTI foi 2º VL/VPTo (ASC 0,92; p < 0,001) e para necessidade de IOT foi 2º VPTo/e (ASC 0,87; p < 0,001). O cutoff escolhido foi 2ºVL/VPTo > 0,42 para a admissão na UTI (s:94,1%; e:82,3%; a:88%); e 2ºVPTo/e < 0,50 para IOT (s:92,9%; e:75%; a:82,3%). Conclusão: As relações volumétricas pulmonares mensuradas pela US3D podem predizer as morbidades neonatais em fetos não hidrópicos com LPC. O VPTo/e e VL/VPTo foram os melhores preditores da morbidade neonatal. Esses dados podem auxiliar no aconselhamento aos pais e na escolha do local mais adequado para o parto / Introduction: Most fetuses with congenital lung malformation (CLM) are asymptomatic and have low morbidity. However, some newborns present respiratory discomfort and need special care. Therefore, decide which cases need to be delivered in a referring center is challenging. Objectives: The purpose of this study was to predict neonatal morbidity in non-hydropic fetuses with CLM assessed by threedimensional ultrasonography (3DUS). Method: Observational study, between January 2005 and January 2016, involving non-hydropic fetuses with CLM. The fetal lung volumes were assessed by 3DUS, by VOCAL technique, in two moments: between 20 and 28 weeks (1st moment) and between 29 and 34 weeks (2nd moment). Intra- and inter-operator variabilities were also evaluated in estimating fetal lung volumes by 3DUS. The following volumetric ratios were assessed: observed / expected normal fetal lung volume (oeTLV), fetal lung lesion volume ratio (LVR), and lesion-to-lung volume ratio (LLV). The lung volumetric ratios were used for the prediction of neonatal morbidity (admission to NICU, need of orotracheal intubation (OTI), or need for lung surgery in neonatal period due to respiratory symptoms). Multivariate regression analyses and receiver operator characteristic curve (ROC) were applied to determine the best volumetric ratio to predict the neonatal morbidity. Results: Forty-five non-hydropic fetuses with CLM were selected for the study. Eighteen (40%) were admitted to the NICU, 14 (31.1%) needed intubation and seven (15.6%) needed neonatal surgery. The variation intra and inter-operator for lung volumes showed good reproducibility and no statistical difference (p>0.05). In the 1st moment (GA: 20 - 28 weeks), all 3DUS ratios (1st oeTLV, 1st LVR, and 1st LLV) demonstrated strong prediction for NICU admission and need of intubation. In the 2nd moment (GA: 29 - 34 weeks), only 2nd oeTLV and 2nd LLV correlated with need of intubation. None of the volumetric ratios (oeTLV, LVR and LLV) were predictive of neonatal surgery. In the 1st moment the best volume ratio for the prediction of NICU admission was 1st oeTLV (AUC 0.86, p < 0.001) and for the need of intubation was 1st LLV (AUC 0.94, p < 0.001). The cut-off chosen for NICU admission was 1st oeTLV < 0.53 (sensitivity 91.7%, specificity 70.8%, accuracy 77.8%); and for the prediction of the need of intubation was 1st LLV > 1.18 (sensitivity 91.7%, specificity 62.5%, accuracy 72%). In the 2nd moment, the best volume ratio for the prediction of NICU admission was 2nd LLV (AUC 0.92, p < 0.001) and the prediction of the need of intubation was 2nd oeTLV (AUC 0.87, p < 0.001). The cut-off chosen for the prediction of NICU admission was 2ndLLV > 0.42 (sensitivity 94.1%, specificity 82.3%, accuracy 88%); and for the prediction of the need of intubation was 2nd oeTLV < 0.50 (sensitivity 92.9%, specificity 75%, accuracy 82.3%). Conclusion: Lung volume ratio measured by 3DUS can predict neonatal morbidity in nonhydropic fetuses with CLM. The oeTLV and LLV were the best predictors of neonatal morbidity. These findings can be useful in counseling parents and in choosing the most appropriate place for delivery
|
505 |
Investigação de sífilis congênita no município de Itapeva (SP): fatores que podem interferir no diagnóstico e tratamento da sífilis na gestação / Investigation of congenital syphilis in Itapeva (SP): factors that may interfere with the diagnosis and treatment of syphilis during pregnancySilva Neto, Sergio Eleuterio da 11 September 2017 (has links)
INTRODUÇÃO: A continuidade das elevadas taxas de sífilis congênita (SC) no Brasil é preocupante, apesar do fácil diagnóstico e tratamento. Os objetivos deste estudo foram: descrever características sociodemográficas, clínico-laboratoriais, assistência ao pré-natal e terapêutica específica das gestantes com sífilis; descrever características clínico-laboratoriais, terapêutica específica e desfecho dos recém-nascidos expostos à sífilis; estimar taxa de incidência anual de SC; estimar frequência de SC entre os recém-nascidos e conceptos expostos; identificar fatores associados à ocorrência de SC entre os conceptos e recém-nascidos expostos. MÉTODOS: Estudo transversal com 149 gestantes com sífilis e 152 recém-nascidos / conceptos expostos, no município de Itapeva (SP), de janeiro de 2010 a dezembro de 2014. Os casos foram identificados pela Vigilância Epidemiológica (VE) e por busca ativa nas Unidades Básicas de Saúde, Centro Materno Infantil, Serviço de Ambulatório Especializado em Infectologia e Santa Casa de Misericórdia. Foi realizada coleta de dados das fichas de notificação de sífilis em gestante (SG) e SC e de prontuários das gestantes e recém-nascidos. Para avaliar a associação de SC com variáveis de interesse, foram calculadas razões de prevalência (RP) e IC95%. Na análise multivariada foi utilizado modelo de regressão de Poisson com variância robusta com nível de significância de p < 0,05. RESULTADOS: A média de idade das gestantes foi 24,3 anos. Oito gestantes não fizeram pré-natal, maioria iniciou pré-natal com idade gestacional <= 13 semanas, realizou mais de seis consultas e 97,2% realizou teste não treponêmico; 57% com resultado VDRL > 1:4. O diagnóstico de sífilis foi feito no momento do parto/curetagem em 11,4% das gestantes; no segundo trimestre da gravidez em 20,8% e no terceiro trimestre em 8,7%. Entre as 132 mulheres diagnosticadas durante a gestação, 77,2% recebeu tratamento adequado >= 30 dias antes do parto; 31,7% fizeram o VDRL mensal para controle de cura. Quanto aos parceiros, 48,3% foi tratado inadequadamente ou não tratado. Ocorreram dois abortos e três natimortos. Em relação aos 147 recém-nascidos vivos, 29,9% foram prematuros, 35,4% teve baixo peso e 51% apresentou sinais de SC ao nascer. Somente 132 recém-nascidos realizaram pelo menos um exame VDRL, com resultado positivo em 65,3%; 55,1% dos recém-nascidos receberam tratamento para sífilis, e a maioria (91,4%) iniciou tratamento no dia do nascimento. Ocorreram cinco óbitos por SC. O pesquisador confirmou 101 casos de sífilis congênita, dos quais 62 foram notificados à VE. Dez crianças apresentaram sequelas. As taxas de incidência de SC foram: 15,1/1.000 NV (2010); 12,1/1.000 NV (2011); 15,6/1.000 NV (2012); 9,1/1.000 NV (2013) e 22,3/1000 NV (2014). Na análise bivariada, tabagismo, <6 consultas pré-natal e idade gestacional >=14 semanas ao diagnóstico de sífilis foram associados à ocorrência de SC. No primeiro modelo da análise multivariada, a idade gestacional ao diagnóstico e o tabagismo foram independentemente associados à SC. No segundo modelo, idade gestacional ao diagnóstico, número de consultas no pré-natal e resultado do primeiro VDRL foram independentemente associados à ocorrência de SC. CONCLUSÃO: As taxas de incidência de SC encontradas pelo pesquisado foram maiores que as informadas pela VE. Os resultados sugerem subnotificação de SG e SC / INTRODUCTION: The continuity of high rates of congenital syphilis (CS) in Brazil is worrying, despite simple diagnosis and treatment. This study had the following objectives: To describe socio-demographic characteristics, clinical laboratory results, prenatal assistance and specific therapy of pregnant women with syphilis; To describe clinical-laboratory characteristics, specific therapeutics and outcome of newborns exposed to syphilis; To estimate annual incidence rate of CS; To determine CS frequency among newborns and proved conceptus; and To identify factors associated with the occurrence of CS between the conceptus and exposed newly born. METHODS: A cross-sectional study was carried out with 149 pregnant women with syphilis and 152 newborns / proved conceptus, in Itapeva (SP), from January 2010 to December 2014. Cases were identified by Epidemiological Surveillance (ES) and by active Basic Health Units, Maternal and Child Center, Specialized Clinic in Infectious Diseases and Santa Casa de Misericórdia. All data were collected from the records of syphilis notification in pregnant women and CS and the records of pregnant women and newborns. To assess the association of CS with variables of interest, prevalence, and 95% confidence interval were calculated. In the multivariate analysis, we used a Poisson Regression Model with robust variance with a significance level of p < 0.05. RESULTS: The mean age of pregnant women was 24.3 years. Eight pregnant women did not get prenatal exams, most started prenatal with gestational age <= 13 weeks, performed more than six medical appointments and 97.2% showed the non-treponemal test; 57% with VDRL result > 1: 4. The diagnosis of syphilis made at the time of childbirth / endometrial curettage was 11.4% of pregnant women; by the second trimester of pregnancy 20.8% and by the third quarter 8.7%. Among the 132 women diagnosed during pregnancy, 77.2% received adequate treatment >= 30 days before delivery; 31.7% did the monthly VDRL for cure control. As for the partners, 48.3% were treated improperly or untreated. There were two miscarriage and three stillbirths. Regarding the 147 live births (LB), 29.9% were premature, 35.4% were underweight, and 51% presented signs of CS at birth. Only 132 newborns performed at least one VDRL test, with a positive result in 65.3%; 55.1% of the newly born received treatment for syphilis, and the majority (91.4%) started treatment on the day of birth. There were five deaths per CS. The investigator confirmed 101 cases of congenital syphilis, of which 62 were notified to the ES. Ten children had sequelae. The incidence rates of CS were: 15.1 / 1000 LB (2010); 12.1 / 1000 LB (2011); 15.6 / 1000 LB (2012); 9.1 / 1000 LB (2013) and 22.3 / 1000 LB (2014). In the bivariate analysis, smoking, = 14 weeks at diagnosis of syphilis was associated with the occurrence of CS. In the first model of multivariate analysis, gestational age at diagnosis and smoking were independently associated with CS. In the second model, gestational age at diagnosis, the number of prenatal appointments, and the outcome of the first VDRL were independently associated with the occurrence of SC. CONCLUSION: The incidence rates of CS found by the researcher were higher than those reported by the ES. The results suggest underreporting of syphilis in pregnant women and CS
|
506 |
Acompanhamento ultrassonográfico, análise da evolução das pieloectasias fetais leves bilaterais e proposta de seguimento pré-natal / Ultrasonographic follow-up, analysis of the evolution of mild fetal bilateral pyelectasis and proposed prenatal follow-upPereira, Gustavo de Paula 04 December 2013 (has links)
OBJETIVO: Este estudo teve por objetivo descrever o resultado dos casos de pieloectasia fetal leve bilateral, encaminhados ao serviço de Medicina Fetal do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP), avaliados com ultrassonografias obstétricas dos rins e do trato urinário do feto e propor, com base nos dados, o melhor acompanhamento em termos de frequência de repetição de exames de ultrassonografia (US), no período pré-natal. METODOLOGIA: Pesquisa longitudinal prospectiva com 62 fetos com diagnóstico ultrassonográfico de pieloectasia leve bilateral (PELB), encaminhados de unidades de cuidados primários, realizada no HCFMUSP. PELB foi considerada quando o diâmetro anteroposterior da pelve renal (DAPPR), media >= 5,0 mm, >= 7,0 mm e >= 10,0 mm à US, respectivamente, em idades gestacionais <= 23 semanas (s) 6 dias (d), 24 s a 31 s 6 d e >= 32 s gestação, sem dilatação de ureteres e cálices. A cada 3 semanas, as US verificaram se a PELB havia progredido, regredido ou tinha ficado inalterada. Assim, quando possível, era realizada uma US de rins e vias urinárias neonatais para confirmação dos desfechos. A progressão foi considerada quando o DAPPR aumentou ou a imagem calicial foi encontrada em um ou ambos os rins. Regressão ocorreu quando os DAPPR entraram nos valores normais. A estabilidade foi considerada quando os DAPPR permaneceram dentro dos parâmetros considerados para pieloectasia leve. RESULTADOS E DISCUSSÃO: A idade gestacional ao diagnóstico foi de 19,2 para 30,1 semanas (média de 23,2 s). Regressão ocorreu em 29 casos (46,7%). Em 24 casos (38,7%), encontrou-se estabilidade. Houve regressão e estado estabilidade em 53 casos (85,4%). Progressão ocorreu em nove casos (14,6%), sendo unilateral em todos. Não foram observados casos graves. Já na avaliação pós-natal, foram examinados 32 neonatos, com 20 casos (62,5%) apresentando regressão; seis (18,7%) de estabilidade da pieloectasia; e seis de progressão da lesão (18,7%). Desfechos de regressão e estabilidade da pieloectasia foram encontrados em 26 casos (81,2%). Os resultados sugerem que as US não devem ser realizadas com frequência em casos de dilatação leve das pelves renais, sem cálices ou ureteres. Uma avaliação ultrassonográfica no terceiro trimestre tardio pode ser suficiente como uma estratégia de acompanhamento rotineiro nesses casos e que essa informação é útil para cuidados pós-natais imediatos. CONCLUSÃO: Esta série indica que PELB fetal, sem cálices ou ureteres visíveis, pode ser controlada ultrassonograficamente no terceiro trimestre tardio e, como não há casos progredindo o suficiente para indicar intervenção fetal, os procedimentos devem ser deixados para o período neonatal. A realização de US seriadas pode ser estressante e inútil nesses casos particulares / OBJECTIVE: The objective of this study was to describe the outcome of cases of mild fetal bilateral pyelectasis, referred to the Fetal Medicine service of Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo (HCFMUSP), assessed with obstetric ultrasound of the kidneys and urinary tract of the fetus in order to propose the best follow-up in terms of repetition frequency of ultrasound examinations in the prenatal period, based on the data. METHODOLOGY: A prospective longitudinal study of 62 fetuses from primary care units with mild bilateral pyelectasis (MBPE) diagnosed using ultrasonography (US) was carried out at HCFMUSP. MBPE was considered when anteroposterior renal pelvis diameter (APRPD) measured >= 5.0 mm, >= 7.0 mm and >= 10.0 mm in US at <= 23 weeks (w) 6 days (d), 24 w to 31 w 6 d and >= 32w gestational age (GA) respectively, with no ureteric and calyces dilatation. US every 3 weeks checked if MBPE had progressed, regressed or remained unchanged. When possible, a neonatal US of kidneys and urinary tract of the newborn was performed to confirm outcomes. Progression was considered when renal pelvis (RP) dilatation increased or visible calyces was found in one or both kidneys. Regression occurred when RP presented normal values. Stability was considered when APRPD remained within the parameters considered for mild pyelectasis. RESULTS AND DISCUSSION: GA at diagnosis was 19.2 to 30.1 weeks (mean 23.2w). Regression occurred in 29 cases (46.7%). In 24 (38.7%) RP dilatation remained unchanged. Regression and unchanged status occurred in 53 cases (85.4%). Lesions worsened in 9 cases (14.6%, unilateral in all cases). No severe cases were observed. 32 newborns already on postnatal evaluation were examined, 20 cases (62.5%) showed involution; 6 cases with stable pyelectasis (18.7%), and 6 cases of lesion progression (18.7%). Outcomes: pyelectasis regression and stability was found in 26 cases (81.2%). Results suggest that US should not be performed too often in cases of RP dilatation with no visible calyces or ureter. A late third trimester US scan could be a sufficient routine follow up strategy in such cases and information is useful to immediate postnatal care. CONCLUSION: This study indicates that fetal MBPE with no visible calyces or ureter could be controlled at late third trimester and procedures should be left to the neonatal period as no cases progressed sufficiently to indicate fetal intervention. Proceeding serial ultrasound scans could be stressful and useless in these particular cases
|
507 |
PRENACEL - uma estratégia de comunicação móvel para melhorar a saúde materna e perinatal: pesquisa formativa e ensaio aleatorizado por conglomerados / PRENACEL - A mobile communication strategy to improve maternal and perinatal health: Formative research and cluster randomized controlled trialFranzon, Ana Carolina Arruda 28 September 2018 (has links)
Melhorar a saúde das gestantes é uma prioridade para as agências de saúde global e para os governos dos países de baixa e média renda. O desafio da erradicação e/ou redução das morbimortalidades materna e perinatal evitáveis vem colocando em destaque a necessidade de expandir as ações para prevenção de agravos para além da abordagem clínica das complicações obstétricas, a partir do fortalecimento dos sistemas de saúde e da valorização da autonomia das mulheres dentro das sociedades, implementando a abordagem de direitos humanos como um dos componentes da qualidade do cuidado à saúde reprodutiva. O objetivo desta pesquisa é determinar se um programa de educação em saúde e apoio às gestantes, adaptado à realidade do Sistema Único de Saúde brasileiro e às especificidades da telefonia celular, é um complemento útil ao acompanhamento pré-natal padrão. A pesquisa foi realizada em duas etapas, tendo início com a condução de uma pesquisa formativa, exploratória, para identificar barreiras e facilitadores da atenção ao pré-natal e parto, avaliar aceitação do uso de mensagens de texto como item complementar ao cuidado pré-natal padrão, e desenvolver e refinar a intervenção do programa PRENACEL. Esta compreende um programa de 148 mensagens de texto no celular com informações essenciais para o acompanhamento do ciclo gravídico-puerperal de mulheres saudáveis, em atendimento na rede pública de saúde. Foi desenvolvida com propósitode melhorar resultados maternos e perinatais. Sua efetividade foi avaliada por meio de um ensaio aleatorizado por conglomerados, realizado em 20 unidades de saúde que provêm assistência pré-natal em uma cidade da região sudeste do Brasil. Gestantes em acompanhamento pré-natal nas unidades de saúde sorteadas para o grupo intervenção foram convidadas a participar do PRENACEL. Em unidades de saúde alocadas ao grupo controle, as gestantes receberam a atenção pré-natal padrão. Os dados analisados foram coletados durante a internação para o parto em quatro maternidades públicas da mesma localidade. Para cada variável de interesse, foram realizadas análise por intenção de tratar e análise por protocolo, pelo cálculo dos riscos relativos, com 95% de intervalo de confiança. Ao final do seguimento da gestação, 1210 mulheres elegíveis à participação no estudo tiveram seus desfechos avaliados nas maternidades selecionadas para a pesquisa, por meio de revisão de prontuários, cartões de pré-natal e entrevista individual estruturada. Das mulheres incluídas nas análises, 770 eram provenientes das unidades de saúde do grupo intervenção e 440 das unidades controle. Receber informações do programa PRENACEL durante a gestação foi associado a um aumento na percepção das mulheres de sentirem-se melhor preparadas para o parto, e na percepção de que o pré-natal colabora para que se sintam mais preparadas. Também foram observados impactos no estabelecimento do contato pele-a-pele e aleitamento materno e no conhecimento sobre intervenções obstétricas. Não foram observadas diferenças nos demais desfechos maternos e perinatais avaliados, incluindo a satisfação das mulheres com o atendimento. Nossa conclusão é de que o PRENACEL pode contribuir para a ampliação do acesso das mulheres a informações que lhes sejam estratégicas para que se sintam melhor preparadas para a experiência do parto. / Improving maternal health is a priority for global health agencies and for governments in low- and middle-income countries. The challenge of reducing preventable maternal and perinatal morbidity and mortality has highlighted the need to expand actions to prevent injuries beyond the clinical approach to obstetric complications, through strengthening health systems and enhancing autonomy of women within societies, by implementing a human rights approach as one of the components of the quality of reproductive health care. The objective of this research is to determine if a program of health education and support to pregnant women, adapted to be used by Brazilian National Health System and delivered by short messages service (SMS) on the cell phone is a useful complement to standard prenatal follow-up. The research was carried out in two stages, starting with the conduction of a formative and exploratory research to identify barriers and facilitators of antenatal and delivery care, to evaluate the acceptance of the use of SMS as a complementary item to antenatal care and to develop and refine the PRENACEL program intervention. It comprises a program of 148 SMS with essential information from pregnancy to puerperium, for healthy pregnant women attending antenatal care. It was developed with the purpose of improving maternal and perinatal outcomes. Its effectiveness was evaluated through a cluster-randomized trial conducted in 20 health units that provide antenatal care in a city in the southeastern region of Brazil. Pregnant women from the health units drawn for the intervention group were invited to participate in PRENACEL. In health unitsallocated to the control group, pregnant women received standard antenatal care. Analyzed data were collected during admission to labor in four public maternity hospitals in the same locality. For each variable of interest, intention-to-treat analysis and analysis by protocol were carried out, as well as the relative risk, with 95% of confidence interval. At the end of the gestation follow-up, 1210 women eligible to participate in the study had their outcomes evaluated in the maternity wards, through their medical records review, antenatal cards review and individual structured interviews. Of the women included in the analyzes, 770 came from the health units of the intervention group and 440 from the control units. Receiving information from the PRENACEL program during pregnancy was associated with an increase in women\'s perception of better preparedness for delivery, and the perception that antenatal care helps them feel more prepared. Enhancement of the timing for early skin-to-skin contact and breastfeeding, and knowledge on obstetric interventions were also observed. No differences were observed in other maternal and perinatal outcomes evaluated, including women\'s satisfaction with care. We concluded that PRENACEL can contribute to increase women\'s access to information that are strategic to the improve their perception of feeling confident and better prepared for the childbirth experience.
|
508 |
Gestações gemelares com pesos discordantes: estudo da predição ultra-sonográfica e dos resultados neonatais / Twin growth discordance: sonographic prediction and factors related to perinatal outcomeMachado, Rita de Cassia Alam 01 November 2006 (has links)
A gemelaridade apresenta algumas intercorrências específicas, como a discordância de peso entre fetos e recém-nascidos (RNs). O objetivo do presente estudo foi predizer a discordância de peso do exame ultra-sonográfico comparada à do parto e avaliar a morbidade e a mortalidade neonatais nas gestações gemelares discordantes quanto ao peso. Este foi um estudo retrospectivo, com levantamento dos casos do período de 1998 a 2004, no Setor de Gestações Múltiplas da Clínica Obstétrica do HCFMUSP. Na avaliação da predição ultra-sonográfica, foram inseridas 221 gestações gemelares e, na avaliação da morbidade e da mortalidade, 151 gestações com partos nessa instituição. A discordância de peso foi definida como >= 20%, sendo excluídos os casos de malformações fetais (n=43) e da Síndrome da transfusão feto-fetal (n=24). Para análise da adequação do peso ao nascimento, utilizou-se a curva de Alexander et al., 1998, para gêmeos. No estudo da predição, foram utilizados quatro intervalos de tempo em relação ao parto (0 a 7 dias - n = 96; 8 a 14 dias - n = 66; 15 a 21 dias - n = 58; 22 a 28 dias - n = 59 gestações), somando 279 avaliações. No grupo de 0 a 7 dias, a estimativa da sensibilidade foi de 93,6%, especificidade de 79,4%, valor preditivo positivo de 89,2%, valor preditivo negativo de 87,1% e acurácia de 88,6%. Nos demais grupos, a sensibilidade e a acurácia foram de 95,8% e 84,9%, 95,6% e 84,5%, 90,9% e 84,8%, respectivamente. Em relação à morbidade, 111 gestações eram concordantes (73,5%) e 40 discordantes quanto ao peso. No grupo discordante, 75% das gestações gemelares apresentaram pelo menos um recém-nascido com Restrição de Crescimento Fetal (RCF). Nesta análise, as gestações gemelares concordantes monocoriônicas obtiveram menor média de idade gestacional no parto (34,3 versus 36,2 semanas, p=0,004), menor peso médio (2067 versus 2334 gramas, p=0,0016) e maior tempo de internação (10,6 versus 7,3 dias, p=0,0023) que as gestações concordantes dicoriônicas. Nas gestações discordantes, não houve diferença significativa em relação à corionicidade. As gestações discordantes, com pelo menos um RN abaixo do percentil 10, apresentaram menor média de idade gestacional (35,2 versus 36,8 semanas, p=0,009) e maior tempo de internação (17,5 versus 8,2 dias, p=0,026). Não foi observada diferença significativa de morbidade e mortalidade entre RNs concordantes e discordantes, com pesos entre os percentis 10 e 90. Os fetos menores das gestações discordantes demonstraram maior freqüência de índice de Apgar inferior a 7 (27,5% versus 7,5%, p=0,01). A avaliação da mortalidade não demonstrou diferença significativa em relação aos grupos concordantes (3,7%) e discordantes (4,5%; p = 1,00). No presente estudo, conclui-se que os quatro grupos apresentaram adequada correlação entre a discordância de peso à ultra-sonografia e no nascimento, porém com melhor predição até sete dias antes do parto. A morbidade neonatal esteve relacionada à RCF do menor feto. A discordância de peso e a corionicidade não interferiram na mortalidade neonatal. / The aim of this study was to evaluate the ability of prenatal ultrasound scans to predict fetal growth discordance in twin pregnancies and perinatal morbidity/mortality associated with these cases. This was a retrospective study (1998-2004) involving twin pregnancies that were scanned and had their delivery at our Institution (HCFMUSP). Cases with fetal malformations (n=43) or twin to twin transfusion syndrome (n=24) were excluded. The study of ultrasound scans consisted of 221 twin pregnancies. The final morbidity/mortality study group consisted of 151 twin pregnancies. Birth weight was evaluated based on twin growth charts published by Alexander et al (1998) and weight discordance as a difference >= 20%. Small for gestacional age (SGA) was defined as birth weight below the 10th centile. The study of ultrasonographic prediction of interwin discordance was made using four different intervals between ultrasound examination and delivery (0 to 7 days, n = 96; 8 to 14 days, n = 66; 15 to 21 days, n = 58; 22 to 28 days, n = 59 pregnancies), with a total of 279 ultrasound examinations. In group 0 to 7 days, the sensitivity was 93,6%, specificity was 79,4%, positive predicted values was 89,2%, negative predicted values was 87,1% and accuracy was 88,6%. In the groups 8 to 14 days, 15 to 21 days and 22 to 28 days the sensitivity and accuracy were 95,8% and 84,9%, 95,6% and 84,5%, 90,9% and 84,8%, respectively. Birthweight discordance was observed in 40 sets of twins (26.5%) and 12 cases were monochorionic MC (30%). Twenty five cases (22.5%) in the non discordant group were MC. In the non discordant group, monochorionic pregnancies showed lower gestational age at delivery (34.3 versus 36.2 wks, p=0.004), lower mean birth weight (2067g versus 2334g, p=0.0016) and longer length of stay in hospital (10.6 versus 7.3 days, p=0.0023) compared to dichorionic twins. In the group with twin birthweight discordance, there were no significant differences between MC and DC pregnancies and 75% of the cases had at least one newborn with SGA. These cases were showed lower gestational age at delivery (35.2 versus 36.8wks, p=0.009) and longer length of stay in hospital (17.5 versus 8.2 days, p=0.026). In the discordant group, the smaller twin had a higher frequency of first minute Apgar score < 7 (27.5% versus 7.5%, p=0.01). Perinatal mortality rate was similar in both groups (discordant 4.5% and concordant 3.7%, p=1.0). There were no significant differences in morbidity and mortality between concordant and discordant twins when birth weight was between the 10 th and 90 th centile. In conclusion, there was a good correlation between fetal growth discordance predicted by prenatal scan and actual birth weight discordance. Neonatal morbidity was related to SGA. Excluding fetal malformation and TTTS cases, birth weight discordance in twin pregnancies is not a significantly associated with neonatal mortality.
|
509 |
Óbito fetal em gestações únicas com diagnóstico de trissomias dos cromossomos 21,18 13 e monossomia do X / Intrauterine death in pregnancies with trisomy 21, 18, 13 and X monosomyGoulart, Vanessa Vigna 10 September 2014 (has links)
Objetivos: Descrever a frequência, e investigar fatores preditivos, de óbito fetal espontâneo (OF), em gestações com anomalias cromossômicas. Métodos: Trata-se de estudo retrospectivo, abrangendo o período de novembro de 2004 a maio de 2012, realizado na Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. Foram incluídas gestações únicas com diagnóstico pré-natal de trissomia dos cromossomos 21 (T21), 18, 13 (T13/18) e monossomia do X (45X), realizado até a 26ª semana de gestação. Resultados: Foram incluídas 92 gestantes com idade materna média de 32,7 ± 8,7 anos. O diagnóstico das anomalias cromossômicas (T21 n=36, T13/T18 n=25, 45X n=31) foi realizado em idade gestacional média de 18,3 ± 3,7 semanas, por meio de biópsia de vilo corial (n=22, 24%), amniocentese (n=66, 72%) e cordocentese (n=4, 4%). Malformação major estava presente em 45 (49%); e hidropisia foi identificada em 32 (35%) fetos, sendo mais frequente no grupo 45X (n=24/31 (77%) versus T21: n=6/36 (17%) e T13/18: n=2/25 (8%), p < 0,001). Exame ecocardiográfico fetal especializado foi realizado em 60% (55/92) das gestações. Dessas, 60% (33/55) apresentaram alterações na morfologia e/ou função cardíaca, sendo o achado mais frequente a comunicação interventricular (39%). Fetos com T13/18 apresentaram incidência maior de anomalias cardíacas (60% versus 25% (T21) e 29% (45X), p= 0,01). Óbito fetal ocorreu em 55 (60%) gestações e foi mais frequente no grupo 45X (n=26/31 (84%) versus T21: n=13/36 (36%) e T13/18: n=16/25 (64%), p < 0,01). A análise multivariada stepwise demonstrou associação entre hidropisia e OF em fetos com trissomia 21 (LR= 4,29; IC95%= 1,9-8,0, p< 0,0001). Em fetos com monossomia X, a presença de alterações ecocardiográficas esteve associada com menor risco de OF (LR= 0,56; IC95% = 0,27-0,85, p= 0,005). Não foram identificados fatores preditores no grupo T13/18. Conclusão: A letalidade intrauterina de fetos com anomalias cromossômicas é elevada. A presença de hidropisia aumenta o risco de óbito fetal, em gestações com trissomia 21. Enquanto, em gestações com monossomia X, a ocorrência de alterações ecocardiográficas reduz esse risco / Objectives: To describe the frequency, and associated factors, of intrauterine fetal death (IUD), in pregnancies with chromosomal abnormality. Methods: This was a retrospective (November 2004 to May 2012) performed at de department of obstetrics, Hospital das Clínicas, São Paulo University Medical School. Inclusion criteria were: singleton pregnancies with prenatal diagnosis of trisomy 21 (T21), 18, 13 (T13/18) and X monosomy (45X), performed up to 26 weeks gestation. Results: 92 women were included in the study with a mean maternal age of 32.7 ± 8.7 years. Fetal chromosomal abnormalities (T21 n=36, T13/T18 n=25, 45X n=31) were diagnosed at a mean gestational age of 18.3 ± 3.7 weeks, by chorionic villus sampling (n=22, 24%), amniocentesis (n=66, 72%) and cordocentesis (n=4, 4%). Major fetal structural abnormality was present in 45 (49%) cases; hydrops was diagnosed in 32 (35%) fetuses, and was more common in 45X group (n=24/31 (77%) versus T21: n=6/36 (17%) and T13/18: n=2/25 (8%), p < 0.001). Specialist fetal echocardiography was performed in 55 (60%) pregnancies and showed structural and/or functional abnormalities in 33 (60%) fetuses; ventricular septal defect was the most common finding (39%). T13/18 fetuses showed a higher incidence of cardiac abnormalities (60% versus 25% (T21) and 29% (45X), p= 0.01). IUD occurred in 55 (60%) pregnancies and was more common in 45X group (n=26/31 (84%) versus T21: n=13/36 (36%) and T13/18: n=16/25 (64%), p < 0.01). Stepwise logistic regression analysis demonstrated an association between hydrops and IUD in T21 pregnancies (LR= 4.29; 95%CI= 1.9-8.0, p < 0.0001). In 45X pregnancies, cardiac abnormalities were associated with a lower risk of IUD (LR= 0.56; 95%CI = 0.27-0.85, p= 0.005). No predictors of IUD were identified in T13/18 group. Conclusion: Intrauterine death rate is high in pregnancies with a fetal chromosomal abnormality. Presence of hydrops increases the risk of this complication in trisomy 21 fetuses. Whereas the presence of a cardiac abnormality is protective in X monosomy pregnancies
|
510 |
Comparação do comprimento do úmero em fetos portadores de Síndrome de Down com o comprimento do úmero em fetos normais / Comparison of humeral length between fetuses with Down syndrome and normal fetusesSilva, Rimena de Melo Germano da 19 February 2014 (has links)
Objetivo: Comparar o comprimento do úmero em fetos portadores de síndrome de Down (T21) com o comprimento do úmero em fetos normais, utilizando instrumentos de referência da população local. Método: Estudo caso-controle retrospectivo que comparou o comprimento do úmero de fetos normais com os fetos com T21, entre 18 semanas e 23 semanas e 6 dias. Os exames dos fetos com T21 foram realizados entre 1994 e 2012. Os controles normais foram avaliados entre 2007 e 2009. Foram analisadas as médias, medianas e desvios-padrão da idade materna, idade gestacional e medida do úmero. Posteriormente, foi feita análise da correlação entre as medidas dos úmeros e a idade gestacional, sendo seus valores expressos em múltiplos da mediana (MoMs). O comprimento do úmero dos fetos com T21 foram confrontados com os fetos normais utilizando o teste t-Student. A medida do úmero foi avaliada considerando-se os níveis de corte abaixo do percentil 10, 5 e 2,5 a fim de obter as respectivas taxas de sensibilidade. Calculou-se, ainda, a razão de verossimilhança (RV). A seguir, foi utilizado um modelo linear geral tendo a idade materna como covariável para controlar na comparação. Comparou-se, também, a medida do comprimento do úmero dos fetos normais da população local com o comprimento do úmero esperado baseado na curva de Jeanty. Os testes foram realizados com nível de significância de 5%. Resultados: Foram incluídos 58 casos com T21 e 1888 controles normais. A sensibilidade do comprimento do úmero para a detecção da T21 utilizando o nível de corte abaixo do percentil 10 foi de 44,8 % com RV de 4,4, abaixo do percentil 5 foi de 34,4 % com RV de 6,9 e abaixo do percentil 2,5 foi de 31,0 % com RV de 12. O valor médio dos úmeros, em MoMs, de fetos com T21 é estatisticamente inferior ao dos fetos normais (p < 0,001), utilizando o teste t-Student. Quando controlada a idade materna na comparação entre os grupos, a diferença permaneceu estatisticamente significativa (p < 0,001). Fez-se uma análise para comparar o comprimento do úmero nos fetos normais da população local com o comprimento do úmero esperado para a curva de Jeanty, e viu-se que os fetos normais locais têm comprimento do úmero estatisticamente significante menor. Conclusões: Existe diferença estatisticamente significante entre o comprimento do úmero de fetos normais e de fetos com T21 na população local (p < 0,001). A sensibilidade para detecção de T21 foi de 44,8%, 34,4% e 31%, para o úmero abaixo do percentil 10, 5 e 2,5, respectivamente. A curva de Jeanty não tem rendimento adequado para uso como controle do crescimento umeral em fetos normais locais, acarretando com seu uso o inevitável aumento da taxa de falsos positivos de úmeros curtos / Objective: This study aimed to compare the humeral length (HL) in fetuses with Down syndrome (T21) with HL in normal fetuses, by using instruments of reference of the local population. Method: A case-control study was conducted comparing HL in normal fetuses with HL in fetuses with T21, aged between 18 weeks and 23 weeks and 6 days. Fetuses with T21 who were examined between 1994 and 2012 were included. The normal controls were evaluated between 2007 and 2009. The averages, medians, and standard deviations were obtained for maternal age, gestational age, and HL. Afterwards, we analyzed the correlation between the HL and the gestational age, with values expressed as multiples of the median (MoMs). The HLs of fetuses with T21 were compared with the HLs in normal fetuses by using Student\'s t-test. The humeri were evaluated considering the cut-off levels below the 10th, 5th, and 2,5th percentiles to obtain the sensitivity. The likelihood ratios (LR) were also calculated. Next, a general linear model was used with maternal age as a covariate to control for comparison of the groups. Comparison was also made between the HL of fetuses in the local population and the expected HL, based on the Jeanty curve. The tests were performed with a significance level of 5%. Results: The study included 58 cases with T21 and 1888 normal controls. The sensitivity of the HL to detect T21 by using a cut-off level below the 10th percentile was 44.8% with a LR of 4.4; below the 5th percentile, the sensitivity was 34.4% with a LR of 6.9; and below the 2.5th percentile, the sensitivity was 31.0% with a LR of 12. The average value of the humerus, in MoMs, of fetuses with T21 is statistically lower than that of normal fetuses (p < 0.001), as measured by using Student\'s t-test. When maternal age was controlled as a covariant in the comparison between groups, the difference remained statistically significant (p < 0.001). An analysis to compare the HL in normal fetuses of the local population with expected HL based on the Jeanty curve concluded that the HL in normal fetuses of the local population is lower than expected. Conclusions: There is a statistically significant difference between the HL of normal fetuses and HL of fetuses with T21 in the local population (p < 0.001). The sensitivity for detection of T21 was 44.8%, 34.4%, and 31% for the humerus below the 10th, 5th and 2.5th percentile, respectively. The Jeanty curve is not adequate to use as growth control for humeri in local normal fetuses, as its use leads to an increase in false positive rates when measuring the proportion of short humeri
|
Page generated in 0.0623 seconds