• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • Tagged with
  • 20
  • 20
  • 10
  • 8
  • 8
  • 8
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Mögel på Textil -vid import av textila varor / Mold growth in Textiles : during import of textile products

Svennered, Alexandra, Carlson, Jenny January 2012 (has links)
Under lagring och transport av textila varor från Asien kan risken för mögelangrepp vara stor, något som sedan vid uppackning kan vara skadligt för hälsan. Situationen så som det ser ut idag kan medföra stora problem och kostnader hos textilföretag och att hitta möjliga åtgärder för att förebygga skador är därför av stort intresse. För att kartlägga problemen med mögelangrepp på textila material har både informationssökning och praktiskt arbete genomförts. Mögeltillväxt sker då det är gynnsamma betingelser med hänsyn till klimat, näring och syretillgång. För att mögeltillväxt inte ska angripa textila varor finns en rad förebyggande åtgärder som kan vidtas, åtgärder som alla handlar om att göra förutsättningarna på ett eller annat sätt ogynnsamma. Olika textila material angrips olika lätt av mögel men genom att hålla varorna rena från smuts samt ha kontroll över den relativa fuktigheten kan varorna klara sig en längre tid utan att bli angripna. Reglering av den relativa fuktigheten kan göras genom användning av avfuktare eller diverse fuktabsorbenter. Även användning av biocider på varorna i samband med packning kan hämma mögeltillväxten. Textila materials benägenhet till att mögla beror på en rad faktorer och efter den mögelodling som satts igång kunde det konstateras att bomull är det material som lättast angrips. Vid uppackning av mögelskadade varor bör försiktighetsprincipen tillämpas och för att rädda de varor som angripits kan olika saneringsmetoder användas, där olika metoder lämpar sig för olika material. Dock har det visat sig, i studier som gjorts på byggmaterial, att vissa saneringsmetoder medfört en kvarvarande eller ökad toxinhalt efter sanering vilket således innebär att sanering inte alltid gör varorna brukbara. During storage and transport of textiles from Asia, the risk of mold growth is high. When unpacking the affected textiles the mold can be harmful to the health of the workers. Today, mold growth in textiles results in major problems and costs for the textile companies. Therefore, it is of great interest for the companies to find possible measures to prevent damages due to mold growth. In order to fully understand the problems with mold on the textiles, both a literature survey and practical work has been done. Mold growth occurs when there are favorable conditions with regard to climate, nutrients and oxygen. There are some preventative measures that can be taken to deter mold growth, which are all about making the conditions, in one way or another, unfavorable.The ease in which different textiles are attacked by mold varies greatly, but by keeping them clean and controlling the relative humidity, the textiles can last a long time without being attacked. The relative humidity can be controlled by using a dehumidifier or various moisture absorbers. Also, using biocides on fabrics during packing may inhibit mold growth. The propensity of mold growth on textiles depends on several factors. The mold experimentsrevealed that cotton is the most easily attacked material. When unpacking the mold damaged goods, the precautionary principle should be used and to save the textiles that have been attacked, different decontamination methods can be used. Different methods are useful for different materials. However, it has been found in studies of construction materials that some decontamination methods lead to residual or increased toxin levels after the decontamination. This means the decontamination does not always make the products usable. / Program: Textilingenjörsutbildningen
12

Fuktegenskaper hos Quartzene impregnerat med salter

Buske, Elias January 2012 (has links)
Svenska Aerogel AB has developed the material Quartzene® which is of the typeprecipitated silica and contains calcium - magnesium silicate ((Ca, Mg) SiO3). Thematerial is used for molecular filtration of contaminated air. Qartzene™, which is inpellet form, is porous and has a high internal surface which is a requirement for themolecular filtration. With the use of various impregnations, filtration can affect thedesired outcome. As an example Quartzene® can be impregnated with Potassiumhydroxide and clear the air of Sulfur dioxide, SO2 (Svenska Aerogel AB, n.d).Svenska Aerogel AB has developed Quartzene® further and new areas of application hasarosee, one of these areas is how the material function within dehumidification. Thepurpose of this study is to research and analyze how different impregnation salts effecthow Quartzene® function in terms of moisture absorption and moisture desorption.Quartzene® is a hygroscopic material, which is a material that easily absorbs and exudatesmoisture from the air. Materials with high porosity absorb moisture by adsorption andcapillary condensation. A hygroscopic material strives for equilibrium with ambientenvironment which is illustrated in a sorption curve where moisture absorption is set inrelation to relative humidity. In this study the jar method is used to measure moistureabsorption, this is shown with the use of sorption curves. The jar method uses saturatesalt solutions to create environments whit a set relative humidity. Quartzene® – pellets areplaced in jars and weighed at regular intervals to determine the moisture absorption.The results of this study indicate that impregnations affect the way that Quartzene®function in terms of moisture absorption and moisture desorption. Some of theimpregnations affect the material to absorb more moisture than Quartzene® that has notbeen impregnated, while others affect the material to absorb less moisture. The resultsalso show that sodium – based impregnation gives similar results as Quartzene® that hasnot been impregnated.
13

Befuktning : Installationer, processer och hälsofördelar. / Humidification : Installations, processes and health benefits.

Cavallius, Matilda, Rehnstedt, Oskar January 2017 (has links)
Det finns tydliga hälsofördelar med en relativ fuktighet på 40–60% inomhus. Trots detta finns det idag inga direktiv på hur man ska styra den relativa fuktigheten inomhus. Många gånger diskuteras det kring avfuktning men i denna rapport tas befuktning upp ur ett hälsoperspektiv.I denna studie har det undersökts huruvida befuktningssystem skulle kunna användas i större utsträckning till fördel för människors hälsa.I rapporten redogörs för olika befuktningmetoder samt deras termofysiska processer - adiabatisk eller isotermisk. Dessutom undersöks vad som händer med energin i luften och vattenångan vid olika temperaturer samt vad olika relativ fuktighet har för hälsomässiga för- och nackdelar.Resultatet visar på att det finns både etablerade befuktningssystem samt ett behov av befuktning. Däremot är efterfrågan av befuktning inte speciellt stor i bostäder och branschen ställer sig negativ till befuktning i ventilationssystem. / There are clear health benefits of having a relative humidity between 40–60% indoors. Despite this, there are currently no directives on what level the relative humidity should be indoors. Today dehumidification is a common matter but this report is about humidification, from a health perspective.In this study, it has been investigated whether humidification could be used to a greater extent, to the benefit of humans’ health.This report describes various humidification methods and their thermophysical processes - adiabatic and isothermal. It is also explained what happens to the energy in the air and water vapor at different temperatures and how the relative humidity affects our health at different levels.The result shows that there is a need for humidification and that there are several technical solutions available today. However, the demand is low and the industry is not very positive to the idea of humidification in ventilation systems.
14

Uttorkning av högpresterande betonggolv : Råd och rekommendationer vid mätning av RF / The drying process of high performance concrete slabs : Advices and recommendations during measurements of the RH

Norin, Max January 2017 (has links)
A development project was undertaken within the consortia formed by Polygon and AK-konsult. The aim of this project was to map out the impact of humidity leakages on the result of humidity measurements in concrete slabs according to the so-called RBK-method. It is behind the idea of this development project that the main purpose of this thesis can be derived from. For instance, an evaluation of already existing data material from a RBK-measurement has been done. A method has been retrieved in order to compare the trend of the measured values of the relative humidity with the trend of the expected values of the relative humidity during the drying process. The main goal has been to implement this method as an instrument to analyze the actual drying process. A survey study was undertaken among the employees of the consortia in order to point out the differences that arise during the installation of the measurement equipment prior to measurement according to the RBK-method. The result of the survey has been summarized and analyzed in purpose to catch a wider glimpse over the different kinds of variables that might have an impact on the result from a RBK-measurement. The outcome from the study of the existing measurement data shows that some of the measurement spots tends to dry out faster than the calculated drying process, while other spots indicates a slower drying process. Three of them actually pointed out that they were under humidity, which implies that they still hadn’t reached the stadium of moisture equilibrium with the concrete. The main reason behind the observed discrepancies might have its explanation in the fact that measurement wholes that have been subjected to a big humidity leakage. The consequence of measurement spots subjected to big humidity leakages, is that the measured value of the relative humidity turns out to be much lower than the actual level of the relative humidity in the concrete. An observation has been made in the plausibility analysis and in the Vaisalaproject that the normative equilibrium time exceeds the number of three days that’s been ordained by RBK. A further study of the normative equilibrium time can thereby be recommended to clarify if it still can be compatible with the different kinds of concrete classes of today.
15

Fuktstudie av en klimatvind på ett äldre småhus : En utredning av effekterna på vindsklimatet vid utvändig takisolering

Laiti, Pär-Henrik January 2017 (has links)
Mögelpåväxt orsakat av fuktproblem är vanligt förekommande på kallvindar i det svenska småhusbeståndet. Enligt en rapport från Boverket har var femte småhus en fuktskada på vinden orsakad av hög relativ fuktighet. Statistik från samma rapport visar att äldre hus med självdragsventilation är drabbade i större utsträckning. Luftläckage av fuktig inomhusluft till vind uppges vara en orsak bakom förhöjd luftfuktighet. Äldre hus är oftast inte lika lufttäta som moderna vilket gör dessa kallvindar mer utsatta. Att tilläggsisolera yttertaket utifrån har visat sig vara en åtgärd som sänker den relativa fuktigheten på kallvindar. Detta brukar kallas för att bygga om kallvinden till en klimatvind.   Denna studie baserar sig på en klimatvind på ett äldre småhus beläget i Skellefteå kommun. Den tidigare kallvinden var drabbad av fuktskador och byggdes därför om till en klimatvind 2014. Sedan dess har ingen utvärdering gjorts om detta är tillräckligt för att fuktsäkra vinden. Syftet med denna studie är därför att ta reda på om klimatvinden på detta hus är fuktsäker till följd av ombyggnaden. Resultatet kommer att användas som ett underlag för att besluta om fler åtgärder är nödvändiga för att fuktsäkra vinden.   För att bedöma fuktsäkerheten har mätningar av temperatur och relativ fuktighet på klimatvinden utförts. Under samma period utfördes även likadana mätningar på en traditionellt uppbyggd kallvind belägen 150 meter från klimatvinden. Genom att jämföra mätresultat mellan dessa vindar kan slutsatser om den utvändiga isoleringens effekt på vindsklimatet göras.   Resultatet av klimatmätningarna visar att den relativa fuktigheten på klimatvinden har legat långt under kritisk nivå för mögeltillväxt. Under samma mätperiod har relativ fuktighet på referensvinden varit i närheten av kritiska nivåer. Klimatvinden har i jämförelse med referensvinden ett varmare och torrare klimat och påverkas inte i lika stor utsträckning av svängningarna i utomhusklimatet. Slutsatsen är att klimatvinden anses vara fuktsäker under mätperioden. Rekommendationen är att fortsätta med klimatmätningar under en helårsperiod för att kunna bedöma fuktsäkerheten ur ett helårsperspektiv. / Mold growth caused by moisture are common in cold attics in small houses in Sweden. According to a report from the National Board of Housing - Boverket, a fifth of all attics in small houses in sweden has moisture problems caused by increased levels of relative humidity. Statistics from the same report show that older houses with natural draft ventilation are affected to a greater extent. Air leakage of damp indoor air into the attic space is said to be one cause of increased humidity. The construction of older houses are usually not as airtight compared to modern houses. This makes the attics in old houses more vulnerable to this problem. Additionally insulation with eps insulation at the outside of the roof has been shown to reduce the relative humidity in cold attics. This report refers to attics with this type of construction as a ”climate attic”   This study is based on a climate attic of a older house located in Skellefteå municipality. The former cold attic had mold problems caused by moisture and was therefore converted to a climate attic in 2014. Since then, no evaluation has been made of the moisture saftey in this climate attic. The purpose of this study is therefore to find out if the climate attic in this house is moisture safe due to the conversion. The results will be used to determining whether more actions are necessary to make the attic moisture safe.   In order to evaluate the moisture safety in the climate attic, measurements of temperature and relative humidity has been made. During the same period measurements were made in a traditionally cold attic. By comparing measurement results between those attics conclusions of the effect from the external isolation can be made. The results from the measurements made in the climate attic shows that the relative humidity has been far below critical levels for mold growth. During the same period the relative humidity in the traditional cold attic has been close to critical levels. In comparison with the traditionally cold attic, the climate attic has a warmer and drier climate and is not affected to the same extent by the fluctuations in the outdoor climate. The conclusion is that the climate attic are considered to be moistureproof during the time measurement was made. The recommendation is to continue with climate measurements over a full-year period to assess moisture safety from a full-year perspective. / <p>Kull H14</p>
16

Klimatanalys av två kulturhus : Med hjälp av relativ fuktighet och temperatur analysera och beräkna mögeltillväxt.

Karlsson, Rebecca January 2019 (has links)
Hullgrensgården och den Harbergska gården är två kulturhus på Smålands östkust, de båda kulturhusen är ouppvärmda vilket har medfört en oro för mögeltillväxt. Sedan 2011 har loggningar av luftens relativa fuktighet och temperatur gjorts på samtliga våningar i de båda kulturhusen. Diagram som redovisar hur den relativa fuktigheten förhåller sig under de fyra år som analyserats (2015-2019), visar att krypgrunden i Hullgrensgården samt de båda vindarna har en kritisk relativ fuktighet en stor del av mätperioden. En mögeldosmodell gjordes på dessa platser, vilken visade att det fanns risk för mögel på samtliga platser. Mikrobiella prov från sex platser skickades inför analys till botaniska analysgruppen. Resultatet visade en riklig frekvens av mögel på de båda vindarna samt i krypgrunden.
17

Meteorologiska mätningar med drönare / Meteorological measurements with drones

Greenland, Christopher January 2019 (has links)
Studien handlade om att belysa hur UAV:s kan komma till nytta i meteorologisk forskning och att ta reda på hur bra drönare är på att mäta meteorologiska storheter. Drönare, som också kallas UAV:s (Unmanned Aerial Vehicle) är mindre obemmanade luftfartyg som kan flyga autonomt eller fjärrstyras. Idag används drönare alltmer i meteorologi vilket beror mycket på den tekniska utvecklingen. Exempel på meteorologiska applikationer är mätning av vindhastighet och koncentrationen av koldioxid i luften som kan användas för att studera de lägsta atmosfäriska skikten. Storheter som mättes i detta projekt var vindhastighet, vindriktning, temperatur och relativ fuktighet på olika höjder. Mätningarna gjordes två gånger i en mätstation i Marsta, som ligger utanför Uppsala. Efteråt jämfördes datan från drönaren med data från en instrumenterad mast vid väderstationen. Resultaten visade att drönarens vindprofiler stämde ganska väl överens med mastens vindprofiler och den logaritmiska vindlagen. Under den första fältmätningen uppskattade drönaren att vindhastigheten var 8.13 ± 1.33 m/s vid hovring på tio meters höjd medan masten angav 8.41 ± 0.958 m/s. Drönarens mätvärden för vindriktningen var ibland bra och ibland mindre bra. Mätvärdena för temperaturen och den relativa fuktigheten avvek med upp mot 1 ◦C respektive 10 procentenheter. / The aim of this report was to study how UAV:s can be applied in meteorological research and find out how good drones are at measuring meteorological parameters. A drone, also known as an UAV (Unmanned Aerial Vehicle) is a smaller unmanned aircraft that can fly autonomously or under remote control. Today, drones are used more frequently in meteorology, mostly due to the recent technological development. Examples of meteorological applications include measurements of wind speed and the amount of carbon dioxide in the air which can be used to analyze the lower parts of the atmosphere. In this project, the wind speed and its direction, the temperature and the relative humidity were measured at different heights. The measurements took place twice in Marsta which is a field station outside Uppsala. Then, the data from the drone was compared to the data from a weather tower at the instrumented station. The results showed that the drone’s wind profiles were relatively similar to the profiles according to the tower and the logarithmic wind profiles. For instance, during the first flight the drone estimated the wind speed to be 8.13 ± 1.33 m/s while hovering ten metres above the ground. The tower measured 8.41 ± 0.958 m/s at the same height. The drone’s estimations of the wind direction were sometimes accurate and sometimes not accurate. The temperature and relative humidity however was different by 1 ◦C and ten percentage units respectively.
18

Ventilation i flerbostadshus- hur fungerar den ur ett fuktperspektiv? / Ventilation in apartment buildings- how does it work in a moisture perspective?

Israelsson, Simon, Hallgren, Anton January 2018 (has links)
För att skapa ett bra inomhusklimat i flerbostadshus ställs höga krav på ventilationssystemet för att ta hand om den fukt som skapas. Det finns således anledning att undersöka om Boverkets byggreglers krav för minsta luftflöde är tillräckligt ur fuktsynpunkt. Syftet är att uppmärksamma problem med ökande fukttillskott i nyproducerade flerbostadshus vilket skulle kunna förändra projekteringen av ventilation i framtiden. För att kunna undersöka om Boverkets byggreglers krav är tillräckligt ur fuktsynpunkt analyseras relativ fuktighet och fukttillskott i fyra flerbostadshus i Jönköping. Det framgår att flera lägenheter erhöll höga värden för fukttillskott och relativ fuktighet vilket kan skada byggnaden och påverka människors hälsa. Boverkets byggreglers krav för minsta luftflöde var otillräckligt ur fuktsynpunkt i flera av de undersökta flerbostadshusen. / To create a good indoor climate in apartment buildings, high demands are made on the ventilation system to take care of the moisture that is created. There is therefore reason to investigate if Boverket, the Swedish National Board of Housing, Building and Planning, requirements for minimum airflow are sufficient from a moisture point of view. The purpose is to rise awareness about increasing additional moisture in newly built apartment buildings, which could change the project planning of ventilation systems in the future. In order to investigate whether requirements of the Boverket building regulations are sufficient from a moisture point of view, relative humidity and additional moisture were analyzed in four apartment buildings in Jönköping. Several apartments received high values of additional moisture and relative humidity which could damage the building and affect human health. The requirements of Boverket building regulations for minimum airflow should therefore be reviewed.
19

Fuktåterföring i roterande värmeväxlare / Moisture feedback in rotating heat exchanger

Malm, Diana January 2012 (has links)
För att ha en chans att ändra trenden med ökande utsläpp av växthusgaser är internationella samarbeten nödvändiga. Därför har EU genom miljökvalitetsmålet Begränsad Miljöpåverkan satt krav på högsta tillåtna utsläpp av växthusgaser. Att sänka energianvändningen för upp- värmning är ett steg i att även sänka utsläpp av koldioxid, som är en av växthusgaserna. Sänkning av energianvändning kan göras på flera sätt, bl.a. genom att öka tjockleken på isoleringen eller återvinna värmen i frånluften. Men dessa åtgärder ska inte helt okritiskt göras.  Att använda roterande värmeväxlare är ett sätt att återvinna värmen i frånluften. Luften passerar då en rotor med öppna kanaler som roterar kring sin egen axel över till tilluftssidan. Detta möjliggör fuktöverföring oberoende om rotorn är hygroskopisk eller ej. Dvs. möjligheten för kanalväggen att ta upp vattenmolekyler eller inte.  Mätningar av relativ fuktighet, temperatur och daggpunkt har gjorts på tre objekt. Därefter har ånghalter och verkningsgrader beräknats. Med objekt menas småhus där roterande värmeväxlare installerats i ventilationssystemet. Objekten är belägna i Linköping, Stockholm och Norge. Ett beräkningsexempel har ställts upp som visar hur fuktverkningsgraden påverkas av olika fukttillskott. I verkligheten råder dock inte stationära förhållanden för fukttillskottet som är en förutsättning för resultaten på dessa beräkningsexempel.  I denna rapport kommer den skrivande således fram till att fuktåterföring sker även för icke hygroskopiska värmeväxlare. Även att fuktverkningsgraden svarar med en viss tröghet vid återhämtning av ett tillfälligt förhöjt fukttillskott. Fuktverkningsgraden är dock betydande för fukttillskott över ca 1-2 g/m3. / To have a chance to change the trend of increased greenhouse gases are international collaborations necessary. Therefore, the EU through the environmental quality objective of Reduced Environmental Impact sat requirements for maximum allowable emissions of greenhouse gases. Reducing energy use for heating is a step that also reduces emissions of carbon dioxide; which is one of the greenhouse gases. Reducing energy use can be done in several ways, including by increasing the thickness of the insulation or heat recovery from exhaust air. However, these measures should not be uncritically made. The use of a rotating heat exchanger is a means to recover heat from exhaust air. The air then passes a rotor with open channels that rotates around its own axis over to the supply air side. This allows moisture transfer regardless of whether or not the rotor is hygroscopic. That is, the ability of the channel wall to take up water molecules or not.  Measurements of relative humidity, temperature and dew point has been made on three objects. Thereafter steam content and efficiencies was calculated. In other words, the objects are referred to single- ore two-family homes where a rotary heat exchanger is installed in the ventilation system. The objects are located in Linköping, Stockholm and Norway. An example calculation is set up that shows how moisture efficiency is affected by different moisture addition. In reality in which the conditions is not stationary the moisture supplement that is a prerequisite for the results of these calculation examples.  In this report, the writer thus concluded that moisture reversal will occur even for non- hygroscopic heat exchangers. Although the moisture efficiency corresponds with a certain slowness in the recovery of a temporarily elevated moisture addition. Moisture efficiency is significant for moisture supplement of about 1-2 g/m3.
20

HotHumiBox, ett provelement mellan två kammare / HotHumiBox, a test element between two chambers

Lekic, Dragan January 2018 (has links)
HotHumiBox är en försöksutrustning som finns på Linnéuniversitetet och som ska ge bättre kunskap och förståelse om hur fukt och temperatur varierar i en provkropp monterad mellan två kammare där klimatet kan styras var för sig. Syftet med examensarbetet är att undersöka om HotHumiBoxen fungerar väl och huruvida den kan börja användas i undervisningen i olika kurser inom institutionen för byggteknik på Linnéuniversitetet, bl.a. i samband med demonstrationslaborationer vid föreläsningar om fukt. För att genomföra arbetet har mätningar med tre olika klimat utförts på ett provelement som motsvarar en yttervägg som kan finnas i nybyggda typhus. Resultatet av mätningar utförda med HotHumiBoxen presenteras i form av tabeller och diagram och jämförs slutligen med beräkningar av fukt- och temperaturtillstånd. Jämförelsen mellan mätningar och beräkningar visar att givarna som styr klimatet i båda kamrarna visar mycket bra resultat. Däremot visar majoriteten av givarna i provelementet antingen lite för höga eller för låga värden för att resultatet ska anses som tillfredställande. För att få en bekräftelse på att HotHumiBoxen fungerar väl rekommenderas därför att ytterligare mätningar görs. / HotHumiBox is an experimental equipment that is available at Linnaeus University and is supposed to provide better knowledge and understanding about the way moisture and temperature varies in a building element installed between two chambers in which the climate can be controlled separately. The purpose of this work is to investigate whether the HotHumiBox works well and whether it can be used at various courses at the Department of Building Technology at Linnaeus University, such as demonstration laboratory experiments at lectures on moisture. Measurements with three different climates were performed on a building element that corresponds to a wall that could be installed in modern houses. The results of the HotHumiBox measurements are being presented in tables and diagrams and are being compared with moisture and temperature calculations. The comparison between measurements and calculations shows that the sensors which control the climate in both chambers show very good results. On the other hand, the majority of the sensors in the test element show either too high or too low values for the result to be considered as satisfactory. Therefore, it is recommended that some more tests and measurements are done before it can be concluded that the HotHumiBox work well.

Page generated in 0.1047 seconds