• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 249
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 255
  • 103
  • 100
  • 66
  • 56
  • 51
  • 49
  • 46
  • 33
  • 32
  • 32
  • 29
  • 24
  • 23
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Abordagem para desenvolvimento de aplicações móveis com reuso de software baseado em modelagem específica de domínio e arquitetura orientada a serviços

Bellini, Alexandre 26 July 2011 (has links)
Made available in DSpace on 2016-06-02T19:05:50Z (GMT). No. of bitstreams: 1 3699.pdf: 5614349 bytes, checksum: 36810f782b315ac66a62c5dcded4dd1e (MD5) Previous issue date: 2011-07-26 / Financiadora de Estudos e Projetos / This dissertation presents an approach for the development of mobile applications emphasizing software reuse based on domain-specific modeling and Service Oriented Architecture. The approach is divided into two stages: Domain Engineering (DE) and Application Engineering (AE). In DE, a metamodel, services and Transformations for Model-To-Code are constructed. The metamodel expresses the abstract syntax of Domain-Specific Languages (DSL) for a given problem domain and services - known as the Domain Services - meet common requirements of different applications of the problem domain for which the metamodel has been built, and Transformations for Model- To-Code to reduce the development effort since most of the coding tasks can be encapsulated in the transformations. In EA, applications are built by instantiating the metamodel in order to support the modeling and by reusing Domain Services. In addition, the transformations, built in ED, are applied to the models in order to generate most of the application code. The reuse of the artifacts built in ED provides a productivity gain in the development of applications of the problem domain considered. For evaluation purposes, the proposed approach has been instantiated in the HealthCare Domain. An experimentation of this approach, following the experimental methodology, has been conducted in order to evaluate its impact on the efficiency of teams that develop applications for Healthcare Domain. The results showed that the use of the proposed approach has contributed to the reduction of time in developing mobile applications. / Essa dissertação apresenta uma abordagem para o Desenvolvimento de Aplicações Móveis que enfatiza o Reúso de Software com base na Modelagem Específica de Domínio e na Arquitetura Orientada a Serviços. A abordagem é dividida em duas etapas: Engenharia de Domínio (ED) e Engenharia da Aplicação (EA). Na ED são construídos: um metamodelo, que expressa a sintaxe abstrata de uma Linguagem Específica de Domínio de um dado domínio do problema; serviços denominados Serviços do Domínio que atendem aos requisitos comuns de diferentes aplicações do domínio do problema para o qual o metamodelo foi construído; e Transformações Modelo-para- Código para reduzir o esforço de desenvolvimento, uma vez que grande parte das tarefas de codificação pode ser encapsulada nas transformações. Na EA são construídas aplicações instanciando-se o metamodelo para apoio à modelagem, bem como reutilizando os Serviços do Domínio. Além disso, as Transformações, construídas na ED, são aplicadas sobre os modelos para gerar grande parte do código das aplicações. O reúso dos artefatos construídos na ED proporciona um ganho de produtividade no desenvolvimento das aplicações do domínio do problema considerado. Para fins de avaliação, a abordagem proposta foi instanciada no domínio de Cuidado de Saúde (Healthcare). Uma experimentação da abordagem, seguindo a metodologia experimental, foi conduzida com o intuito de avaliar seu impacto na eficiência de equipes desenvolvendo aplicações para esse domínio. Os resultados evidenciaram que o uso da abordagem proposta colaborou para a redução de tempo no desenvolvimento de aplicações móveis.
242

Dialisador capilar reutilizado e de uso único em hemodiálise : implicações na saúde dos profissionais, em desfechos clínicos e custos / Single-use and reused capillary dialyzer in hemodialysis : implications for the health of professionals, clinical outcomes and costs / Dializador capilar reutilizado y de un solo uso en hemodiálisis : implicaciones para la salud de los profesionales, desenlaces clínicos y costos

Silva, Olvani Martins da January 2016 (has links)
A reutilização do dialisador capilar em hemodiálise é uma prática realizada em muitos países, apesar de não haver consenso sobre sua segurança e eficácia em comparação ao dialisador de uso único. Em relação ao uso único, apontam-se os custos como grande entrave e a preocupação com o aumento do lixo hospitalar. No que se refere aos riscos do reuso, aponta-se a exposição dos profissionais aos produtos químicos necessários à realização do processo de reutilização, assim como movimentos repetitivos envolvidos na dinâmica dessa técnica; somadas a isto, a redução da eficiência da membrana, a contaminação do sistema, as infecções cruzadas, as reações pirogênicas e as bacteremias. Nesse sentido, tornam-se relevantes estudos que investiguem o efeito da adoção desses métodos nesses desfechos. Objetivos: Comparar as implicações do dialisador reutilizado (reuso) com as do utilizado uma única vez (uso único) na saúde dos profissionais, nos desfechos clínicos e custos de pacientes em hemodiálise. Métodos: Estudo longitudinal, com coleta de dados retrospectiva, realizado em um Hospital Público Universitário (Janeiro de 2015 a Fevereiro de 2016). Foram incluídos 18 técnicos de enfermagem e 34 pacientes renais crônicos submetidos à hemodiálise nos dois períodos do estudo (período de reuso e período de uso único), por meio de cateter, fístula ou enxerto, com fluxo de sangue de pelo menos 300 ml/min. e tempo de diálise definido entre três a quatro horas por sessão. Considerou-se como desfechos primários os distúrbios osteomusculares, irritação ocular, as dermatoses, afastamento do trabalho e uso de medicações. Como secundários, hemodinâmica, volemia, exames laboratoriais, reações pirogênicas, bacteremias, uso de antibióticos e custos diretos e indiretos do procedimento. Projeto aprovado no Comitê de Ética da instituição. Resultados: O tempo médio de trabalho dos 18 técnicos de enfermagem foi de 12±7 anos. Durante o período de reutilização do dialisador, houve sete notificações. Verificou-se uma taxa de exposição ao uso de medicamentos de 6,7 dias para cada 1.000 profissionais no período de reuso do dialisador; 1,52 dias de exposição à medicação para cada 1.000 profissionais no período de uso único do dialisador (RDI= 4,4; IC 95%: 2.182-9.805); os dias de afastamento foram semelhantes entre os períodos. Nos 34 pacientes estudados nos dois períodos, foram semelhantes os parâmetros hemodinâmicos e volêmicos; houve redução de ureia pós-diálise, creatinina, fósforo, ferritina, hematócrito e hemoglobina durante o uso único do dialisador; foi observado um risco 91% menor de pirogenia no uso único do dialisador, se comparado ao período de reuso (RC= 0,091; IC 95%: 0,002-0,625). Não houve diferença significativa na presença da bacteremias (p= 0,125); a vancomicina foi utilizada empiricamente para tratar a pirogenia. Para cada paciente em hemodiálise utilizando o dialisador reutilizado, o valor médio foi R$ 23,18; e com o dialisador de uso único foi de R$ 39,77 (p= 0,002). O custo indireto médio mensal durante o período de reuso foi de R$ 168,07 (R$ 0,37 por sessão); e para o uso único foi de R$133,23 ao mês (R$ 0,29 por sessão). O custo indireto não apresentou diferença estatística comparando o reuso e uso único do dialisador (p= 0,463). Conclusão: O reuso do dialisador esteve associado a distúrbios osteomusculares, irritação ocular e dermatoses entre os profissionais de enfermagem, além de maior uso de medicamentos. O uso único do dialisador reduziu pequenos solutos, ferritina, hematócrito, hemoglobina, e apresentou menor risco de pirogenias e bacteremias. Quanto aos custos, o reuso do dialisador obteve benefícios adicionais em relação aos custos diretos. Entretanto, para custos indiretos, o reuso não apresentou diferença em relação ao uso único. / Capillary dialyzer reuse in hemodialysis is a practice carried out in many countries, although there is no consensus about its safety and effectiveness in comparison with the single-use dialyzer. Regarding the single-use dialyzer, costs are considered a major obstacle, as is the concern with the increase in medical waste. In what concerns the risks of reuse, the exposure of the professionals to chemicals needed to carry out the process of reuse, as well as the repetitive movements involved in the dynamics of this technique stand out; added to this, there are the reduced efficiency of the membrane, the contamination of the system, cross-infections, pyrogenic reactions and bacteremia. In this sense, a study which investigates the effect of the adoption of these methods in these outcomes becomes relevant. Objectives: To compare the implications of reused dialyzer with single-use dialyzer on the health of professionals, clinical outcomes and costs of patients in hemodialysis. Methods: Longitudinal study with retrospective data collection, carried out in a Public University Hospital (January 2015 to February 2016). Participated in the study 18 nursing technicians and 34 chronic kidney patients subjected to hemodialysis in the two periods of the study (reuse and single-use periods), through catheter, fistula or graft, with blood flow of at least 300 mL/min, dialysis time set between three to four hours per session. Musculoskeletal disorders, eye irritation, skin diseases, work leave and the use of medications were considered as primary outcomes. Secondary included hemodynamics, blood volume, laboratory tests, pyrogenic reactions, bacteremia, antibiotic use, direct and indirect costs of the procedure. The project was approved by the Ethics Committee of the institution. Results: The average time of work of the 18 nursing technicians was 12±7 years. During the period of dialyzer reuse there were seven notifications. There was a rate of exposure to the use of medicines of 6.7 days for each 1,000 professionals within the period of dialyzer reuse; 1.52 days of exposure to medication for each 1,000 professionals in the period of single use of the dialyzer, (IDR = 4.4; 95% CI: 2,182-9,805); the days of work leave were similar between periods. In the 34 patients studied in the two periods, the hemodynamic and blood volume parameters were similar; there was reduction of urea after dialysis, creatinine, phosphore, ferritin, hematocrit and hemoglobin during the single use of the dialyzer; 91% less risk of pyrogenic reaction was noted in the single use of the dialyzer compared to the period of reuse (OR = 0.091; 95% CI: 0.002-0.625). There was no significant difference in the presence of bacteremia (p = 0.125); vancomycin was used empirically to treat pyrogenic reactions. For each patient on hemodialysis using the reused dialyzer, the average value was R$ 23.18 and with the single-use dialyzer, R$ 39.77 (p=0,002). The average monthly indirect cost during the period of reuse was 168,07R$ (0.37 R$ per session), and for the single-used period, R$ 133,23 per month (0.29 R$ per session). The indirect cost showed no statistical difference comparing the reuse and the single use of the dialyzer (p = 0.463). Conclusion: The reuse of the dialyzer was associated with musculoskeletal disorders, eye irritation and skin diseases among nursing professionals, in addition to more frequent use of medicines. The single use of the dialyzer reduced small solutes, ferritin, hematocrit hemoglobin, and showed lower risk of pyrogenic reactions and bacteremia. In what concerns the costs, the reuse of the dialyzer obtained additional benefits concerning the direct costs. However, for indirect costs, reuse exceeded single use values. / La reutilización del dializador capilar en hemodiálisis es una práctica realizada en muchos países, aunque no hay ningún consenso sobre su seguridad y eficacia en comparación al dializador de uso único. Con relación al uso único, se señalan los costos como un gran obstáculo, además del incremento de los residuos hospitalarios. En lo respecta a los riesgos del reuso, se señala la exposición de los profesionales a los productos químicos necesarios para la realización del proceso de reutilización, así como los movimientos repetitivos involucrados en la dinámica de esta técnica; se suma a esto la reducción de la eficiencia de la membrana, la contaminación del sistema, las infecciones cruzadas, las reacciones pirogénicas y las bacteriemias. En este sentido, estudios para investigar el efecto de la adopción de estos métodos en estos desenlaces se vuelven relevantes. Objetivos: Comparar las implicaciones del dializador reutilizado (reuso) con las del dializador de un solo uso (uso único) para la salud de los profesionales, desenlaces clínicos y costos de los pacientes en hemodiálisis. Métodos: Estudio longitudinal, con recopilación retrospectiva de datos, realizado en un Hospital Público Universitario (desde Enero 2015 hasta Febrero 2016). Se incluyeron 18 técnicos de enfermería y 34 pacientes renales crónicos sometidos a hemodiálisis en los dos periodos de estudio (periodo de reuso y periodo de uso único), a través de catéter, fístula o injerto, con flujo de sangre de por lo menos 300 ml/min y tiempo de diálisis definido entre tres y cuatro horas por sesión. Se consideraron como desenlaces primarios los trastornos osteomusculares, irritación ocular, dermatosis, alejamiento del trabajo y uso de medicaciones. Como secundarios, se consideraron la hemodinámica, volemia, exámenes de laboratorio, reacciones pirogénicas, bacteriemias, uso de antibióticos y costos directos e indirectos del procedimiento. El proyecto fue aprobado por el Comité de Ética de la institución. Resultados: El tiempo medio de trabajo de los 18 técnicos de enfermería fue de 12±7 años. Durante el periodo de reutilización del dializador, hubo siete notificaciones. Se verificó una tasa de exposición al uso de medicamentos de 6,7 días para cada 1.000 profesionales en el periodo de reuso del dializador; 1,52 días de exposición a la medicación para cada 1.000 profesionales en el periodo de uso único del dializador (RDI= 4,4; IC 95%: 2,182-9,805); los días de alejamiento fueron similares entre los periodos. En los 34 pacientes estudiados en los dos períodos, los parámetros hemodinámicos y volémicos fueron similares; hubo una reducción de urea después del diálisis, y de creatinina, fósforo, ferritina, hematocrito y hemoglobina durante el uso único del dializador; se observó un nivel de riesgo de piogenia 91% menor en el uso único del dializador, en comparación con el periodo de reuso (RC= 0,091; IC 95%: 0,002-0,625). No hubo diferencia significativa en la presencia de bacteriemias (p= 0,125); la vancomicina fue utilizada empíricamente para tratar las reacciones pirogénicas. Para cada paciente en hemodiálisis utilizando el dializador reutilizado, el valor medio fue de R$ 23,18; y con el dializador de uso único fue de 39,77 R$ (p= 0,002). El costo indirecto medio mensual durante el periodo de reuso fue de 168,00 R$ (R$ 0,37 por sesión); y para el uso único fue de R$ 133,23 al mes (R$0,29 por sesión). El costo indirecto no presentó diferencia estadística comparando el reuso y el uso único del dializador (p= 0,463). Conclusión: El reuso del dializador estuvo asociado a trastornos osteomusculares, irritación ocular y dermatosis entre los profesionales de enfermería, además de un mayor uso de medicamentos. El uso único del dializador ha reducido pequeños solutos, ferritina, hematocrito, hemoglobina, y ha presentado un riesgo menor de reacciones pirogénicas y bacteriemias. En cuanto a los costos, el reuso del dializador ha obtenido beneficios adicionales con relación a los costos directos. Sin embargo, para los costos indirectos, el reuso no ha presentado diferencia con relación al uso único.
243

Eletroxidação de cloranfenicol e outros poluentes organicos utilizando reatores eletroquimicos, constituidos de anodos tipo DSA ou de diamante dopado com boro (DDB) / Electrooxidation of chloramphenicol and otherpollutants using electrochemical reactors composed with a DSA type anode or a boron-doped diamond anode

Spitzer, Marcos 30 September 2005 (has links)
Orientador: Rodnei Bertazzoli / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-05T06:46:31Z (GMT). No. of bitstreams: 1 Spitzer_Marcos_D.pdf: 1019872 bytes, checksum: 57974ac02038eb53169c99987a119811 (MD5) Previous issue date: 2005 / Resumo: O método de oxidação eletroquímica foi aplicado a soluções aquosas contendo cloranfenicol (CAP) e outros compostos orgânicos. Para isso, utilizou-se um anodo de óxido condutor, comercial, tipo DSA®, de composição 70TiO2-30RuO2 e um anodo de diamante dopado com boro (DDB) tipo comercial. Cada anodo foi instalado em um reator tipo filtro-presa, em escala de bancada, para processamento de 2 a 3 L de solução em modo de batelo-reciclo. Inicialmente, nos reatores construídos foram realizados estudos voltamétricos, em modo hidrodinâmico. Sobre um catodo de aço inoxidável, antes da evolução de H2, observou-se a redução do grupo NO2 do CAP a HO-NH- a pH=5, e em potenciais anódicos, sobre o DSA®, observou-se o início reação de evolução de O2 a partir de 1 V vs. ECS e que a presença de CAP reduz as correntes de evolução de O2. Sobre o DDB, o CAP é oxidado a partir de 0,6 V resultado na passivação do anodo. A partir de 2,2 V observa-se o início da evolução de O2 sobre o DDB, resultando na eliminação do filme passivador. Em seguida, eletrólises exaustivas foram realizadas, em modo galvanostático, com ambos os anodos, dentro da região de evolução de O2. Cinéticas de pseudo-primeira ordem foram observadas dos decaimentos ds CAP sobre o DSA®, na faixa de 50 a 180 mA cm-2, e sobre o DDB, na faixa de 10 a 30 mA cm-2. Os decaimentos da demanda química de O2 (DQO) e do carbono orgânico total (COT) também apresentaram essa cinética quando as reações de oxidação sobre o DDB tornavam-se controladas pelos processos de transporte de massa. A partir de eletrólises de soluções de K2SO4 com o DDB observou-se a geração de H2O2. Os números adimensionais Sherwood (Se), Reynolds (Re) e Schmidt (Sc) foram determinados a partir de dados de transporte de massa obtidos a partir de cinéticas da degradação do CAP em função da vazão. No reator composto de DSA® observou-se um regime de fluxo laminar a baixo de Re = 2000 e um regime de fluxo turbulento acima desse valor, como esperado para um reator de placas paralelas. No reator de DDB, devido o aumento da área da secção transversal do compartimento entre eletrodos, há uma elevação de turbulência da face do anodo, impedindo a formação de um regime de fluxo laminar bem definido. Utilizando um efluente real contendo fenóis e derivados, foram aplicadas valores apropriados de densidade de corrente (Jap) para aumento dos valores de eficiência de corrente e diminuição dos índices de consumo energético. Aplicando-se um perfil exponencial de Jap (t) obteve-se um rendimento de corrente médio de 95 % e um consumo de 23,5 kWh por kg de O2. Com isso foi possível propor um método de operação de reatores de DDB para elevação dos índices de eficiência. De modo geral, os anodos de Ti/70TiO2-30RuO2 e de DDB ótimos desempenhos para a eletroxidação de cloranfenicol (CAP) e outros compostos orgânicos e para redução da DQO e do COT / Abstract: Electrochemical oxidation was used as a method for organic pollutant degradation in aqueous media. In the technique was used in solutions containing chloramphenicol (CAP) and phenolic compounds. A commercial DSA® type anode, of composition 70TiO2-30RuO2, and a boron-doped diamond anode (BDD) were used. Each anode was mounted in a filter-press type reactor connected to a recirculating flow system with 3 L of capacity. Initially, voltammetric studies were carried out with electrochemical reactors operating in hydrodynamic mode. On the DSA® type anode O2 evolution reaction was observed after 1 V vs. SCE and the current densities for O2 evolution decreased when chloramphenicol was present in solution. On stainless steel cathode, before H2 evolution, reduction of NO2 group to HO-NH- group was observed for CAP molecule, at pH = 5. On DDB, the anode was passived with an organic film at potentials from 0.6 V. Current responses on DDB anode were restored after anodic treatments within O2 evolution range of potentials. On BDD, O2 evolution took place after 2.2 V vs SCE. Galvanostatic experiments were carried out within the range of potentials for O2 evolution. Pseudo-first order kinetics were observed for CAP concentration decay on the DSA® anode, when current densities (Jap) were ranged from 50 to 180 mA cm-2, and from 10 to 30 mA cm-2 on DDB anode. Chemical oxygen demand (COD) and total organic carbon (TOC) showed linear concentration decays when the oxidation reactions were controlled by charge transfer process and it showed exponential decays when these reactions were controlled by mass transfer process. H2O2 production on DDB anode was investigated as function of Jap. Dimensionless numbers and their mass transfer figures of merit were studied from mass transport data of CAP decays as function of several flow rates. In the reactor composed by DSA® anode, a laminar flow was observed below Reynolds (Re) equal 2000 and a turbulent flow was observed above this value. In the BDD reactor, the transition between laminar and turbulent flow was not observed. Using a real effluent composed by phenols and derivates, appropriate values of Jap was applied on DDB reactor to increase the anodic efficiency and to reduce the energy consumption per kg of O2. Applying an exponential profile of Jap in galvanostatic experiments, an anodic efficiency of 95% was reached, corresponding to an energy consumption of 23,5 kWh per kg of O2. From these results an operation method of BDD reactors arose in order to increase the performance of this electrochemical device. Good performances were observed when DSA® and BDD anodes were used in electrochemical oxidation of chloramphenicol and other organic pollutants, especially in BDD case / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
244

Sistema de filtração lenta no tratamento de percolado do aterro sanitario de Limeira-SP / Slow sand filter in the treatment of leachate of the sanitary landfill of Limeira -SP

Pelegrini, Nubia Natalia de Brito 17 February 2006 (has links)
Orientador: Jose Euclides Stipp Paterniani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-06T12:32:37Z (GMT). No. of bitstreams: 1 Pelegrini_NubiaNataliadeBrito_M.pdf: 1010430 bytes, checksum: 1a5af5bc021dbf527427add6944a6e6d (MD5) Previous issue date: 2006 / Resumo: A disposição final de resíduos sólidos é uma prática que ainda traz sérios impactos ao meio ambiente. Nos aterros sanitários, os resíduos passam por processos físicos, químicos e biológicos de decomposição, gerando uma fração gasosa (composta principalmente por gases dióxido de carbono e metano) e uma fase líquida conhecida como chorume (ou percolado de aterro sanitário). O chorume de lixo é um líquido com elevado potencial poluente, os métodos convencionais utilizados em seu tratamento têm descartado-o com intensa coloração e alta toxicidade. Este trabalho teve como objetivo implantar em escala piloto um sistema de filtração lenta precedido de uma pré-filtração, apenas em manta sintética não tecida, para o tratamento de chorume de lixo ¿in natura¿, proveniente do aterro sanitário da cidade de Limeira-SP. O filtro lento foi constituído por um tanque cilíndrico de plástico tendo como meio filtrante areia e mantas sintéticas não tecidas. A taxa de filtração adotada durante os experimentos foi de 3 m3/m2.dia. O sistema de tratamento em estudo apresentou reduções consideráveis dos valores de alguns parâmetros de controle ambiental indicando a possibilidade do uso da filtração lenta para remediação de águas residuárias. As principais reduções obtidas referem-se a 40% de turbidez, 21% da coloração, 35% de dureza, 35% de carbono orgânico total (TOC) e reduções consideráveis de metais pesados (60% de cádmio, 30% de chumbo, 25% de cobre e 30% de cromo). Com relação à reutilização do chorume tratado em atividades agrícolas ainda são necessárias maiores reduções dos valores de parâmetros analíticos através da complementação com outras tecnologias de tratamento / Abstract: The final disposition of solids residues is a practice that still brings serious impacts to the environment. In sanitary landfill, the residues goes through physical, chemical and biological decomposition processes, generating into a gas phase (mainly composed by CH4 and CO2) and a liquid phase known as leachate. The waste leachate is a liquid with high pollutant potential. The conventional methods used in the treatment this residue have discarded him with intense coloration and high toxicity. This work had as objective implant in pilot scale a system of slow sand filtration preceded of a pré-filtration, only in non-woven synthetic fabrics, for the waste leachate treatment in natura, originating from the sanitary landfill of the city of Limeira-SP. The slow sand filter is constituted by a plastic cylindrical tank, sands and non-woven synthetic fabrics. The filtration rate adopted during the experiments it was of 3 m3/m2.dia. The treatment system in study presented considerable reductions of some values of environmental parameters control indicating the possibility of the use of the slow filtration for remediação of wastewaters. The main obtained reductions were 40% of turbidity, 21% of color, 35% of hardness, 35% of total organic carbon (TOC) and reductions considerably of heavy metals (60% of cadmium, 30% of lead, 25% of cupper and 30% of chrome). For the reuse of the treated leachate in agricultural activities are necessary larger reductions of some values of analytic parameters through the complementation with other treatment technologies. eywords: Landfill Leachate, Sanitary Landfill, Slow Sand Filtration, Reuse / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
245

A importância dos fatores ambientais na reutilização de imóveis industriais em São Paulo. / Considering soil quality in industrial sites redevelopment in São Paulo.

Anna Carolina Marques Ayres da Silva 30 September 2002 (has links)
O presente trabalho aborda uma questão ainda relativamente nova, mas de urgente reflexão: a reutilização de imóveis industriais, considerados hoje, áreas potencialmente contaminadas (AP) por atividades não industriais. Objetiva documentar a postura mais freqüentemente utilizada no Brasil quando da reocupação da implantação de novos usos em imóveis industriais desativados, adotando-se como parâmetro o município de São Paulo. Busca averiguar se, em algum momento deste processo, há qualquer consideração sobre a possibilidade da existência de passivo ambiental, dada a natureza industrial da atividade anteriormente desenvolvida no imóvel. Parte da hipótese que os agentes envolvidos nesse processo de mudança de uso (incorporadoras, construtoras, etc) ignoram ou desconsideram a possível existência de contaminação no imóvel. A metodologia consistiu na seleção dos imóveis, a partir de uma base cartográfica (4 cartas – escala 1: 25.000 da EMPLASA) que registrava o uso do solo em 1980. Posterior visita ao campo e registro do uso atual destes imóveis. Os que apresentaram um novo uso não industrial foram analisados e se dentro dos parâmetros desejados, sujeitos a uma entrevista. O resultado das entrevistas comprovou a hipótese inicial. Conclui-se que, a reincorporação destes imóveis ao tecido urbano dá-se sem qualquer preocupação quanto à existência de uma possível contaminação do solo, dos aqüíferos ou das instalações se reaproveitadas. Mesmo se, durante a construção do novo empreendimento, tenham sido observados indícios de uma provável contaminação. Não há qualquer interesse na investigação da qualidade do solo e água, além do usual, para execução das fundações. Do ponto de vista dos agentes envolvidos, somente a exigência de um órgão público justificaria tal atitude. / This research refers to a very new problem, which needs urgent reflection and response: the new land uses in industrial areas, considered potentially contaminated. The research intends to define which is the more common attitude in Brazil for redevelopment of decommissioning industrial plants areas, focused on São Paulo city. It aims to examine the process of redevelopment projects, in order to discover if there is any consideration about the environment quality during the land uses changes. It takes as hypothesis that the agent involved in land uses changes process ignore completely the existence of contaminated sites. The methodology was grounded and developed by using charts (4 charts- scale 1:25.000 –.EMPLASA), which indicated the industrial plants in 1980. Later visit on land to verify their current uses. The agents involved in the installation of new non-industrial establishments were interviewed about the process. In summary, one can say that the reintegration of these decommissioning industrial areas is done without any kind of deeply concerns about the contaminated sites, or the impact of the past industrial activities on the groundwater quality, or in the abandoned installations. There isn’t any further interest in order to investigate the possibility of environmental liabilities and consequent risks and hazards.
246

Incorporação de lodo gerado na Estação de Tratamento de Água Tamanduá, como ativo em massas para cerâmica vermelha / Incorporation of sludge generated in the Tamanduá Water Treatment Plant Incorporated, with addition of a red ceramic mass

Tartari, Rodrigo 05 December 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:09Z (GMT). No. of bitstreams: 1 Rodrigo Tartari.pdf: 9550409 bytes, checksum: 139b195eb1b11dbe7bfc7a238de6d98b (MD5) Previous issue date: 2008-12-05 / The objective of this work is to research the development of methods for utilizing the sludge generated in the Tamanduá water treatment plant, located in the city of Foz do Iguaçu - PR, as a prime material for the production of red ceramic. For this purpose, it was used beyond the mud, four clays originating geological region of western Paraná, called: Plastic (OP) and Sand (AO) from Santa Rita Ceramic and Plastic (AP) and Sand (AA) from de Artisans Cooperative of Foz do Iguaçu PR (COOAFOZ), used for production of red ceramic. The methodology is divided into: characterization of the 5 materials for determination of humidity, organic matter, loss by fire, limits of sil consistency, residues, grain fineness, chemical and mineralogy, in the second phase of the investigation, seven binary mistures were made among the clays from Santa Rira Cermics and from COOAFOZ, varying the weight of both in proportion of 0, 30, 40, 50, 60, 70 and 100%. Were up 336 bodies of evidence by uniaxial pressing, tested dry and after sintering at temperatures of 950 o and 1050 °C, measured before the following tests: total linear contraction, water absorption, apparent porosity, loss by fire, apparent specific mass, strength the bending, scanning electron microscopy and microanalysis. It was found that the clay AP and OP showed characteristics of high plasticity with major composition of SiO2, Al2O3 and Fe2O3 and grains < 2&#956; equivalent to 19.4 and 21.6, respectively. When these clays the AP and OP in greater weight percentages in the mixtures, the intensities of interaction between clay processing were positively evaluate the physical-mechanical properties of bodies of evidence. Mixtures A1 (100% AP), A2 (70% AP + 30% AA), B1 (100% AP) and A2 (70% AP + 30% AA), showed better results on water absorption of less than 25% and resistance to bending than 60 kgf/cm2 at a temperature of 950 °C and more than 80 kgf/cm2 to 1050 oC. In these compositions, is incorporated 4, 8, 12 and 16% of dry sludge to determine the maximum permissible load without causing cracks and deformations. It was found that the sludge presented characteristics of silty clay of low plasticity, can replace clay similar to 8% in the production of red ceramic. According to analysis of results, have been building blocks of 6 holes for the method of extrusion incorporating 8% of wet mud is found that the physical mechanical properties evaluated were: linear contraction of 8.6%, 24% water absorption and 46 kgf /cm2 of resistance to compression, and within the rules for production of red ceramic coating for (bricks). It appears that the sludge was incorporated as the mass of wet clay, about 75% of initial water when received from the water treatment plant Tamanduá, contributing to process of maturation. It was concluded that based on the results obtained in the laboratory that the sludge generated in the water treatment plant of the unit Tamanduá in Foz do Iguaçu - PR can be used as an additive in the manufacture of bodies for red ceramic. / Este trabalho tem por objetivo pesquisar o desenvolvimento de métodos para utilizar o lodo gerado na Estação de Tratamento de Água Tamanduá, localizada na cidade de Foz do Iguaçu/PR, como matéria-prima para produção de cerâmica vermelha. Para atingir a finalidade proposta, utilizaram-se além do lodo, quatro argilas de formação geológica da região oeste do Paraná, denominadas por: Plástica (OP) e Areia (OA) da Cerâmica Santa Rita e Plástica (AP) e Areia (AA) da Cooperativa de Artesões de Foz do Iguaçu PR (COOAFOZ), empregadas para produção de cerâmica vermelha. A metodologia subdividiu-se em: caracterização das 5 matérias-primas pela determinação da umidade, matéria orgânica, perda ao fogo, limites de consistência de solos, resíduos, granulometria, composição química e mineralógica. Na segunda fase da investigação, fez-se sete misturas binárias entre as argilas da Cerâmica Santa Rita e da COOAFOZ, variando o peso de ambas em 0, 30, 40, 50, 60, 70 e 100%. Foram confeccionados 336 corpos de prova por prensagem uniaxial, analisados a seco e após sinterização nas temperaturas de 950 e 1050 oC, avaliados perante os seguintes ensaios: contração linear total, absorção de água, porosidade aparente, perda ao fogo, massa específica aparente, resistência à flexão, microscopia eletrônica de varredura e microanálise. Verificouse que as argilas AP e OP apresentaram características de alta plasticidade com presença majoritária de SiO2, Al2O3, e Fe2O3 e grãos < 2&#956;, iguais a 19,4 e 21,6 respectivamente. As argilas AP e OP em maiores porcentagens peso nas misturas intensificaram as interações entre os argilominerais, isto é, no processamento obtiveram-se resultados positivos diante a avaliação das propriedades físico mecânicas dos corpos de prova. As misturas A1 (100% AP), A2 (70% AP + 30% AA), B1 (100% OP) e B2 (70% OP + 30% OA), apresentaram melhores resultados com relação à absorção de água menor que 25% e resistência à flexão superior a 60 kgf/cm2 na temperatura de sinterização a 950 oC e superior a 80 kgf/cm2 à 1050 oC. Nestas composições, incorporaram-se 4, 8, 12 e 16% de lodo seco para determinar a carga máxima admissível sem causar trincas e deformações. Verificou-se que o lodo apresentou características de argilas siltosas de baixa plasticidade, podendo substituir argilas similares em até 8% na produção de cerâmica vermelha. De acordo com análise dos resultados obtidos, fizeram-se blocos estruturais de 6 furos pelo método de extrusão incorporando 8% de lodo úmido, e verificou-se que as propriedades físico-mecânicas avaliadas foram as seguintes: 8,6% de contração linear, 24% de absorção de água e 46 kgf/cm2 de resistência à compressão, estando dentro das normas de produção de cerâmica vermelha para revestimento (tijolos). Destacou-se que o lodo incorporado na forma úmida à massa de argila, com cerca de 75% de água inicial quando recebido da Estação de Tratamento de Água Tamanduá, contribuiu no processamento de maturação da mesma. Portanto, conclui-se com base nos resultados que o lodo gerado na Estação de Tratamento de Água da unidade Tamanduá em Foz do Iguaçu PR pode ser utilizado como aditivo na fabricação de massas para cerâmica vermelha.
247

PADRÕES ARQUITETURAIS PARA O DESENVOLVIMENTO DE APLICAÇÕES MULTIAGENTE / ARCHITECTURAL STANDARDS FOR THE DEVELOPMENT OF MULTI-AGENT APPLICATIONS

Silva Junior, Geovane Bezerra da 20 March 2003 (has links)
Made available in DSpace on 2016-08-17T14:52:46Z (GMT). No. of bitstreams: 1 Geovane bezerra.pdf: 1597415 bytes, checksum: 1a51bd2c6aed9c1c6ee46b8369083350 (MD5) Previous issue date: 2003-03-20 / This work proposes a collection of architectural patterns for the development of multi-agent systems. Main architectural concerns like communication, cooperation and coordination mechanisms between the agents of the society are particularly analyzed in each described pattern. The generation of new patterns through the extension or composition of the proposed ones is also approached. The methodology for pattern extraction is based on the study of frequently used architectures of multi-agent systems, like blackboard and federative architectures, and on mechanisms of cooperation and coordination usually identified in such architectures, like master-slave, meeting and negotiator mechanisms, as well. Pattern description is based on AUML and KQML. Main AUML diagrams, like agent packages, agent diagrams and agent interaction diagrams are used to represent the structure and behavior of the society. In those diagrams, agent interactions are represented as KQML performatives. Proposed patterns are validated through the construction of three case studies related to the development of multi-agent systems for information retrieval and filtering. In these case studies, the architectures RETSINA, AMALTHAEA and ABARFI are analyzed and the reuse or potential application of proposed patterns is identified. / Este trabalho propõe uma coleção de padrões arquiteturais para o desenvolvimento de sistemas multiagente. Os principais problemas arquiteturais tais como comunicação, cooperação e mecanismo de coordenação entre os agentes são analisados e descritos em cada padrão. A geração de novos padrões pela extensão ou composição dos padrões propostos também é abordada. A metodologia utilizada para extração de padrões está baseada no estudo de arquiteturas de sistemas multiagente freqüentemente utilizadas, como as arquiteturas quadro-negro e federativas e nos mecanismos de cooperação e coordenação geralmente identificados em tais arquiteturas, como os mecanismos mestre-escravo, reunião e negociador. A descrição dos padrões está baseada em AUML e KQML. Os principais diagramas da AUML, como o diagrama de pacotes, o diagrama de agente e o diagrama de interação são usados para representar a estrutura e o comportamento da sociedade. Nesses diagramas, a representação das interações entre os agentes é feita com a utilização das performatives de KQML. Os padrões propostos são validados através da construção de três estudos de caso relacionados ao desenvolvimento de sistemas multiagente para recuperação e filtragem de informações. Nesses estudos de caso, são analisadas as arquiteturas RETSINA, AMALTHAEA e ABARFI e é identificado a potencial reutilização ou aplicação dos padrões propostos.
248

UMA METODOLOGIA BASEADA EM ONTOLOGIAS PARA A ENGENHARIA DE APLICAÇÕES MULTIAGENTE / A METHODOLOGY BASED ON ONTOLOGIAS FOR THE ENGINEERING OF APPLICATIONS MULTI - AGENT

Lindoso, Alisson Neres 10 March 2006 (has links)
Made available in DSpace on 2016-08-17T14:52:48Z (GMT). No. of bitstreams: 1 alisson lindoso2.pdf: 6722921 bytes, checksum: 2f55fa8a7f109106c015f0307cb7582c (MD5) Previous issue date: 2006-03-10 / The increasing demand of software applications constructed conciliating productivity, low cost and high quality, even in complex and changeable domains, turns necessary the elaboration of techniques and methodologies focusing on development paradigms more suitable for approaching these conflicting features, like the multiagent one. On the other hand, the sotware reuse process promotes the creation of new applications employing reusable software artifacts previously developed. This work introduces MAAEM, an ontology-driven methodology for analysis, design and implementation of multi-agent applications through the reuse of models and components that represent the requirements of a family of applications in a domain as well as the corresponding agent-oriented solutions to these ones. ONTORMAS, an ontology whose instantiation is useful for modeling and representing specific applications developed with MAAEM methodology, is also presented. Two case studies elaborated in order to evaluate the methodology and ontology are also described, exploring the cases with and without reuse, respectively, in the touristic and juridical domains. / A crescente demanda por aplicações de software cuja construção concilie produtividade, baixo custo e alta qualidade, mesmo em domínios complexos e mutáveis, torna necessária a elaboração de técnicas e metodologias que foquem paradigmas de desenvolvimento mais adequados para abordar aquelas características conflitantes, tal como o paradigma multiagente. Por outro lado, o processo de reutilização de software permite promover a criação de novas aplicações empregando artefatos de software reutilizáveis previamente desenvolvidos. Esse trabalho introduz a MAAEM, uma metodologia baseada em ontologias para a análise, o projeto e a implementação de aplicações multiagente através do reuso de modelos e componentes que representam os requisitos de uma família de aplicações em um domínio, assim como as correspondentes soluções orientadas a agentes para tais requisitos. É também apresentada a ONTORMAS, uma ontologia cuja instanciação é útil para modelar e representar aplicações específicas desenvolvidas com a metodologia MAAEM. São descritos ainda dois estudos de caso elaborados no sentido de avaliar a metodologia e a ontologia, explorando os casos com e sem reuso, respectivamente, nos domínios turístico e jurídico.
249

O impacto de reúso de dialisadores nos marcadores de estresse oxidativo e inflamatórios em pacientes em hemodiálise / Evaluation of oxidative stress and inflamatory markers on hemodialysis patients with and without dialysers reuse

Carla Barbosa Muraro Furlan 27 March 2014 (has links)
A morbimortalidade dos pacientes em hemodiálise permanece alta apesar da evolução tecnológica do procedimento, sendo que os eventos cardiovasculares são a sua principal causa. Estes desencadeados pela alta prevalência de fatores de risco tradicionais, fatores relacionados ao procedimento dialítico e estresse oxidativo. Considerando o procedimento dialítico e o estresse oxidativo, foi avaliado o quanto a habitual prática de reuso de dialisadores/RD (difundida nas Américas e amparada principalmente por questões econômicas) e uso único de dialisadores, influenciam nos marcadores inflamatórios e de estresse oxidativo. Para isto, foram utilizados como marcadores laboratoriais as medidas de PCR ultrassensível (u PCR), interleucina 6 (IL6), a determinação de substâncias reativas ao ácido tiobarbitúrico (TBARS), superóxido dismutase (SOD), glutationa (GSH) e albumina, em 29 pacientes em tratamento de hemodiálise. Estes pacientes encontravam-se em tratamento com dialisadores de alto fluxo do tipo polieterssulfona e reuso manual, e ao iniciar este estudo foram programados 3 ciclos sequenciais com duração de 6 semanas com as seguintes características: primeiro ciclo (uso único de dialisadores;); segundo ciclo (reuso de dialisadores); terceiro ciclo (reuso de dialisadores e administração de N-acetilcisteína/NAC, na dose de 1200 mg/dia). Foram coletadas amostras de sangue de cada paciente no início e final da última sessão de hemodiálise anteriormente ao início dos ciclos (denominado Período 1) e no início e final da última sessão de hemodiálise de cada ciclo (denominados Períodos 2, 3 e 4 respectivamente). O TBARS aumentou no período de uso único. Todas as demais variáveis não apresentaram diferença significativa. Os resultados indicaram que o RD pode proporcionar uma melhora no estresse oxidativo. O uso único foi associado com maior estresse oxidativo. Não foi encontrado nenhum benefício adicional com NAC / The morbidity and mortality of patients undergoing hemodialysis remains high despite the technological development of this procedure, and cardiovascular events are the main causes of morbidity and mortality. These cardiovascular events are triggered by the high prevalence of traditional risk factors, factors associated with dialysis procedures, and oxidative stress. Considering the factors associated with dialysis procedures and oxidative stress, we assessed how dialyzer reuse (DR; widespread in the Americas, especially because of economic issues) and use of single-use dialyzers influence oxidative stress and inflammatory markers. We used ultrasensitive PCR (u-PCR) to measure levels of the laboratory markers interleukin-6 (IL6), thiobarbituric acid reactive substances (TBARS), superoxide dismutase (SOD), glutathione (GSH), and albumin in 29 patients undergoing hemodialysis treatment. These patients were receiving treatment with polyethersulfone high-flux dialyzers and manual reuse. In the initial phase of this study, the 3 following sequential cycles, each lasting 6 weeks, were scheduled: first cycle (single-use dialyzers); second cycle (DR); and third cycle (DR and administration of N-acetylcysteine [NAC] at a dose of 1200 mg/day). Blood samples were collected from each patient at the beginning and end of the last hemodialysis session that preceded the start of the cycles (termed Period 1), and at the beginning and end of the last hemodialysis session of each cycle (termed Periods 2, 3, and 4, respectively). The levels of TBARS increased during the single-use period. The remaining variables did not show significant differences. The results indicated that DR may ameliorate oxidative stress. Single-use dialyzers were associated with higher oxidative stress. No additional benefit was found with use of NAC
250

Apoiando a composição de serviços em um ecossistema de software científico

Marques, Phillipe Israel 23 August 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-10-23T17:43:12Z No. of bitstreams: 1 phillipeisraelmarques.pdf: 8922079 bytes, checksum: 6a86d6e40e9d80c77e61a71e2c42f8e5 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-11-09T13:52:35Z (GMT) No. of bitstreams: 1 phillipeisraelmarques.pdf: 8922079 bytes, checksum: 6a86d6e40e9d80c77e61a71e2c42f8e5 (MD5) / Made available in DSpace on 2017-11-09T13:52:35Z (GMT). No. of bitstreams: 1 phillipeisraelmarques.pdf: 8922079 bytes, checksum: 6a86d6e40e9d80c77e61a71e2c42f8e5 (MD5) Previous issue date: 2017-08-23 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A área de e-Science envolve a realização de experimentos científicos complexos, normalmente apoiados por workflows. Esses experimentos geralmente utilizam dados e recursos distribuídos, e podem ser apoiados por uma plataforma de ecossistema de software científico. Neste contexto, é necessário permitir que diferentes serviços web possam ser compostos, reutilizados, além de interoperarem na plataforma para tratar das complexidades dos experimentos. Entretanto, compor serviços em plataformas de ecossistemas é uma atividade complexa, considerando, sobretudo, os requisitos funcionais e não funcionais desses serviços. Diante disso, o objetivo deste trabalho é apresentar um mecanismo que busca apoiar a composição de serviços no contexto de um ecossistema de software científico. Para tanto, esse mecanismo é associado ao processo de criação de serviços da plataforma de ecossistema de software científico. Oferece elementos de visualização para representar os relacionamentos de dependência funcional e interoperabilidade entre os serviços. Além disso, utiliza a análise de redes sociais científicas para identificar potenciais colaboradores. Os pesquisadores identificados poderão interagir com o auxílio das visualizações existentes, no espaço de trabalho compartilhado, para avaliar as composições. Essa plataforma, denominada E-SECO, apoia as diferentes fases do ciclo de vida de um experimento científico. A partir desse mecanismo, cientistas interagem e analisam as relações entre serviços nas composições realizadas considerando, sobretudo, as métricas de dependência funcional e a interoperabilidade entre os serviços existentes em diferentes instâncias da plataforma. Visando avaliar o mecanismo para apoiar a composição de serviços, foram realizados estudos de caso na plataforma E-SECO. / The area of e-Science encompasses performing complex scientific experiments, usually supported by workflows. These experiments generally use distributed data and resources, and can be supported by a scientific software ecosystem platform. In this context, it is necessary to allow different web services to be composed, reused, and interoperate in the platform to deal with the complexities of the experiments. However, performing services composition on ecosystem platform is a complex activity which requires computational support, considering, above all, the functional and non-functional requirements of these services. Therefore, the goal of this work is to present a mechanism that aims to support services composition in scientific software ecosystem context. To this end, this mechanism is associated to the service construction process of the scientific software ecosystem platform. It also provides visualization elements to represent functional dependency and interoperability relationships between the services. In addition, it uses scientific social networks analysis to identify potential collaborators. The identified researchers may interact through the visualizations, in the shared workspace, to evaluate the compositions. This platform, named E-SECO, supports different phases of the scientific experiment life cycles. From this mechanism, scientists interact and analyze the relationships between services in compositions which were performed considering, above all, the functional dependency metrics and interoperability issues between existing services in different instances of the platform. In order to evaluate the mechanism to support services composition, case studies were carried out on the E-SECO platform.

Page generated in 0.0774 seconds