• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 124
  • 32
  • 2
  • Tagged with
  • 158
  • 69
  • 29
  • 28
  • 16
  • 15
  • 14
  • 13
  • 13
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Kalibrering och validering mot uppmätt data med hjälp av IDA ICE : En fallstudie av miljonprogrammets flerbostadshus

Köyluoglu, Idris, Moalin, Hussein January 2020 (has links)
The aim of this thesis is to create an energy simulated model with IDA ICE (IDA Indoor, Climate and Energy) of a multy – family apartment located in Andersberg, Gävle and then validate the model against measured district heating. The model will be used in future renovations by the property owner AB Gavlegårdarna and involved consultants to investigate energy savings measures. The district of Andersberg is located 4 kilometers south of Gävle City. The studied construction is a five-floor multi-family residential building with about 50 apartments. It was built under the Swedish Million Programme which had its constructing period during 1965 – 1974 century. These buildings need renovation and energy efficiency. Sweden has implemented several goals, including reducing the total energy use per unit of floor space in residential and commercial buildings with 50 % until 2050. In order to execute this study, a preliminary investigation, site visits, measurements, literature study, calculations and energy simulation were accomplished. The research method that is used for this thesis is a case study used by simulation of a building where a calibrated model against measured data for energy use is created. By calibrating simulation models, it gives a better model that matching the real building operating performance. An energy signature method performed by Martin Eriksson, who is a postgraduate of energy systems, is used to validate the building loss factor. The calibrated model can later be used to identify and estimate energy saving measures. An evidence-based method is applied to maintain choice of important data for build energy simulation. These selections are used for input parameters when creating the model and are based on the priority order in a defined source hierarchy. The results of the study achieved where not to pass a difference of 10 % between simulated result and measured data. The simulated needed district heating energy for the building deviate only with 5 % against district heating energy received from Gävle Energi. The buildings facility electricity and household electricity were taken from energy declaration for the building and Svebys standardized values for using calibrating. It is resulting a difference with 7 % respective 1.2 % between simulated and calibrating data.
12

Validering av forskningsmätrum med avseende på magnetfält

Näsström, Michael, Nygren Wåhlin, Elin January 2015 (has links)
För att kunna bedriva forskning i det nybyggda rummet på Karolinska Universitetssjukhuset vid Rosenlunds Sjukhus krävs det att magnetfäl- tet valideras. Detta är av vikt att undersöka för att kontrollera om det finns möjlighet att installera en teleslinga, samt säkerställa att mag- netfältet som genereras från högtalarna inte blir för stort för framtida forskning på bland annat hörapparater med telespole. Magnetfältsnivån mättes i tomt rum och med inkopplade högtalare som genererade ett monotont ljud motsvarande talstyrkan hos en vux- en man. Bakgrundsmagnetfältet var i det stora hela inom gränsvärdena givna av IEC 60118-4 bortsett från ett fåtal mätpunkter. Vid högtalarmät- ningarna visade det sig däremot att flertalet mätpunkter intill högta- larna inte höll sig inom gränsvärdena. Magnetfältet, som genererades av strömmen till högtalarna, avtog snabbt med avståndet. Detta med- för att högtalarnas placering är av betydelse och att det bör tas hänsyn till. / To perform research in a new room at Karolinska University Hospital, Rosenlund Hospital, it has to be validated regarding to magnetic field. This is of importance to verify if it is possible to install a hearing loop, as well to make sure that the magnetic field generated from the speak- ers does not cause problems at future research regarding for example hearing aids with a telecoil. The magnetic field level was measured in the room when it was empty and with connected speakers generating a monotonous sound corre- sponding the speech level from a grown man. The background magnetic field level was mainly within the limits given by IEC 60118-4 aside from a few measuring points. The measurements with speakers connected showed that several measuring points close to the speakers were not within the limits. Although the magnetic field, generated by the current to the speakers, decreased rapidly with dis- tance. The placement of the speakers are therefore significant and have to be accounted for.
13

Lärares erfarenheter av validering på Komvux

Thor, Cecilia, Thor, Kristina January 2007 (has links)
Thor,Cecilia och Thor Kristina (2006) Lärares erfarenheter av validering på Komvux. ( Teatcher´s experience of assessment at Komvux). Skolutveckling och ledarskap, Lärarutbildningen 60p, Malmö Högskola.Syftet med denna uppsats är att undersöka vad lärare,som arbetar med validering inom omvårdnadsprogrammets flexibla vuxenutbildning,har för erfarenheter av dagens valideringsprocess på Komvux.Vi vill också ta reda på om de har några förslag på förändringar eller förbättringar gällande valideringsprocessen.Vi har intervjuat nio lärare som arbetar på tre olika Komvuxskolor.Resultatet visar att många lärare vill flytta valideringsprocessen från skolmiljön till den kliniska verksamheten.De anser också att själva bedömningen av en individs kunskaper bör ske individuellt men själva självskattningen kan göras i grupp.Vidare menar lärarna att svenska språket har stor betydelse i valideringssammanhang.Nationella riktlinjer och nationell valideringsutbildning är något som vissa lärare anser vara viktigt för att få en likvärdighet i valideringsprocessen.
14

Validering av en fluoridelektrod / Validation of a fluoride electrode

Martinet, Nicolas January 2022 (has links)
Målet med projektet var att validera en jonselektiv fluoridelektrod för att säkerställa att instrumentets prestanda har för tillämpningen godtagbart mätområde, precision och riktighet. Parametrar som mellanliggande precision, repeterbarheten och LOD (Limit of detection) och LOR (Limit of reporting) har beräknats. Detta har gjorts i syfte att ta instrumentet i bruk på ALS Danderyd för analys av vattenprover.  Kalibrering av instrumentet har utförts genom att med tillverkade standarder ta fram två kalibreringskurvor. Det behövdes två kurvor för att få en bättre riktighet vid låga koncentrationer. Då koncentrationer vid lägre område inte visar på ett linjärt samband behövdes det också flera punkter inom det låga området. En kalibreringskurva omfattar analys av låg koncentrationer fluorid inom 0,1- 0,5 mg/l och en kalibreringskurva för högre koncentrationer mellan 0,5- 10 mg/l. Påverkan av interferenser som kan störa mätningarna har inte påvisats då analys av lakvatten genomfördes.  Under en 10-dagarsperiod har 3 olika kemister analyserat höga och låga halter av fluorid i syfte att ta fram mellanliggande precision och repeterbarheten. Resultaten utifrån dessa försök visar relativ standardavvikelse för repeterbarheten 1.7 % för kontroll låg och 0.5 % för kontroll hög vilket ligger innanför acceptanskriterium under <5%. Mellanliggande precision för kontroll låg 2.9 % och 1.7 % för kontroll hög hamnade under acceptanskriterium <10%.  Kontroll av CRM (Certified Reference Materials) av olika koncentrationer gjordes för kontroll av riktigheten. Ett utbyte på 100,02 % för CRM material av låg koncentration och 97,91 % av hög koncentration redovisades och ligger inom acceptanskriterium på runt 90-110 % som fastställs av ALS.  Slutsatser som kan dras utifrån analyser och beräkningar som har gjorts visar att instrumentet är lämpat för bruk då precision och riktighet visat goda resultat. / The goal of the project was to validate a ion selective electrode for measuring fluoride to ensure the instrument's performance has the measuring range, precision and accuracy that is needed. Parameters such as intermediate precision, repeatability and LOD (Limit of detection) and LOR (Limit of reporting) have been calculated. This has been done for the purpose of using the instrument at ALS Danderyd for analysis of water samples.  Calibration of the instrument has been performed by using manufactured standards for two calibration curves. Two curves were needed to obtain a better accuracy at low concentrations. As concentrations at the lower range do not indicate a linear relationship, several points were also needed within the low range. A calibration curve includes analysis of low concentrations of fluoride within 0.1-0.5 mg / l and a calibration curve for higher concentrations between 0.5-10 mg / l. The effect of interferences that can interfere with the measurements has not been demonstrated when analysis of leachate is performed.  During a 10-day period, 3 different chemists have analyzed high and low levels of fluoride in order to produce intermediate precision and repeatability. The results from these experiments show relative standard deviation for repeatability 1.7% for control low and 0.5% for control high which is within the acceptance criterion below <5%. Intermediate precision for control was 2.9% and 1.7% for control high fell below the acceptance criterion <10%.  Checking CRM (Certified Reference Materials) of different concentrations is done to check the accuracy. A yield of 100.02% for CRM materials of low concentration and 97.91% of high concentration was reported and is within the acceptance criteria of around 90-110% as determined by ALS.  Conclusions that can be drawn from the analyzes and calculations that have been made show that the instrument is suitable for use as precision and accuracy have shown good results.
15

Effekterna av en kort färdighetsträning i valideringsteknik för läkarstudenter / The Effects of a Short Training in Validation Technique for Medical Students

Braide, Lisa, Nilsson, Emma January 2015 (has links)
No description available.
16

Psykometrisk utvärdering av den modifierade versionen av Jag tycker jag är

Nilvang, Karolina January 2006 (has links)
<p>Trots att självkänsla är ett frekvent studerat ämne saknas en allmänt erkänd teori och definition som kan utgöra en grund då självkänsla studeras. Gemensamt för flertalet teorier är att självkänslan grundläggs i barndomen samt att självkänsla rör en persons uppfattning om sig själv och personens omdöme om hur han eller hon uppfattas av omvärlden. Studiens syfte var att göra en psykometrisk utvärdering av en modifierad version av Jag tycker jag är samt att studera formulärets test-retest reliabilitet. Jag tycker jag är utvärderades genom att analyseras tillsammans med andra välprövade självkänsloskalor. Undersökningsdeltagare var 100 psykologistuderande (M = 28.4 år; s = 7.3 år). Majoriteten av skalorna var starkt positivt korrelerade med varandra och uppvisade en tillfredställande reliabilitet. Resultatet av test-retest undersökningen visade att skalorna i Jag tycker jag är hade tillförlitlig reliabilitet gällande precision och stabilitet över tid (r = .81 - .97). Utgående från resultatet konstaterades att Jag tycker jag är har hög konstrukt validitet och tillfredsställande reliabilitet.</p>
17

Lastbilsförare med invandrarbakgrund : Varför ser jag så få lastbilsförare med invandrarbakgrund i svenskregistrerade lastbilar?

dahlström, peter January 2008 (has links)
No description available.
18

Mikrosimulering för analys av Mästergatans förlängning i Enköping / Micro simulation for analyzing an extension of Mästergatan in Enköping municipality

Edgren, Magnus January 2009 (has links)
<p>Two of the main approach roads into the city of Enköping are Salavägen and Stockholmsvägen. They are connected to each other through the street Bangårdsgatan in the roundabout Salatullen and crossing Fannakorset, respectively. These crossings are from time to time heavily loaded, which is why the municipality plan for a new street in parallel to Bangårdsgatan. The traffic will then be spread out and is thereby reducing the density. The new street is actually an extension of the existing Mästergatan, a side street to Salavägen, to the east and connecting it to Stockholmsvägen or a street nearby.</p><p>The purpose of this Master thesis is to show how the new street can be drawn in order to discharge the traffic in the area between the roundabout Salatullen and the crossing Fannakorset. Three alternatives have been worked out by the municipality as follows:</p><p>Alt 1 – connection to the road Stockholmsvägen north of the railroad tracks</p><p>Alt 2 – connection to the street Bangårdsgatan through a tunnel under the railroad</p><p>Alt 3 – connection to the crossing Fannakorset through a tunnel under the railroad</p><p>These alternatives are analyzed using micro simulation with a forecast of the traffic volumes in year 2030 created by the municipality. Only week days during peak hour (4 pm until 5 pm) are treated. The work has been carried out assuming that the new road is connected to existing roads through T-junctions with two lanes. It is concluded that Alt 3 best spreads the traffic on the roads in the system with good overall availability. However, if the connection is made with a roundabout, Alt 2 is as good as Alt 3.</p><p>With a desired increase of the traffic flow on Mästergatan, its intersection to the commercial area Myran may be crucial if it is not properly dimensioned. It is therefore important that the design of this intersection is thoroughly planned to be able to serve the desired traffic demand and enable the discharge of Bangårdsgatan as well as the system in whole.</p> / <p>Salavägen och Stockholmsvägen är två in- och utfarter till Enköpings tätort. De kopplas samman via Bangårdsgatan i korsningarna Salatullsrondellen och Fannakorset. Dessa korsningar är tidvis hårt belastade och man planerar därför att skapa en parallellgata till Bangårdsgatan för att sprida ut trafiken. Detta ska ske genom att förlänga Mästergatan, som idag är en kort sidogata till Salavägen i väster, österut för anslutning till eller i närheten av Stockholmsvägen.</p><p>Syftet med detta examensarbete är att visa på hur den nya Mästergatan ska dras för att nå så stor avlastning som möjligt i området söder om järnvägen, mellan Salatullsrondellen och Fannakorset. Tre möjliga sträckningar av Mästergatan har arbetats fram av kommunen enligt följande:</p><p>Alt 1 – passage norr om järnvägen för anslutning till Stockholmsvägen</p><p>Alt 2 – passage genom tunnel under järnvägen för anslutning till Bangårdsgatan</p><p>Alt 3 – passage genom tunnel under järnvägen för anslutning till Fannakorset</p><p>De olika alternativen analyseras efter att ha simulerat dem på mikronivå. För detta används en trafikprognos för år 2030 som arbetats fram i kommunen. Endast vardagar mellan kl. 16:00 och 17:00 behandlas. Undersökningen har gjorts med förutsättningen att den nya sträckningen ansluts till befintliga vägar i en rak T-korsning med två filer. Slutsatsen är att förorda alternativ 3 eftersom man i det fallet får en bra avlastning av hela det nuvarande trafiksystemet i området med genomgående god framkomlighet. Om anslutningen av den nya vägen istället görs med cirkulationsplats blir alternativen 2 och 3 likvärdiga.</p>
19

Modellering och reglering av hyttgasnät

Hultman, Björn, Ingemanson, Johannes January 2004 (has links)
<p>Examensarbetet behandlar en modellering av hyttgasnätet vid SSAB Oxelösund AB. Det objektorienterade modelleringsspråket Modelica används. Modellen valideras statiskt och dynamiskt för olika driftsfall med gott resultat. </p><p>Hyttgasen används delvis för generering av elektricitet i kraftverket. Simuleringar av modellen visar att hyttgasnätets konstruktion begränsar inflödet av hyttgas till kraftverket. Modellen används för att studera förändringar av hyttgasnätet som kan öka inflödet till kraftverket. I examensarbetet föreslås byte av de befintliga brännarna i kraftverket, införande av två extra brännare eller införande av en tryckstegringsfläkt. Samtliga förändringar möjliggör en ökad elproduktion i kraftverket, detta leder till ökad vinst för SSAB. </p><p>Olika driftsstörningar i hyttgasnätet simuleras för att ge förslag på åtgärder som kan minska störningen. Ett snabbstopp av kraftverket ger en tryckstegring i nätet. Störningen kan minskas genom att facklorna regleras av trycket i gasnätet, tryckregleringen kombineras med dagens reglering mot gasklockans nivå. När ett snabbstopp i blåsmaskinen studeras kan en modifiering av regulatorn till reglerspjället göras. Förändringen medför att gasklockans nivå stabiliseras. </p><p>För att minska förlusterna av gas bör facklornas reglering ändras. Facklornas reglering kan förbättras genom att fördelningen av den hyttgas som ska förbrännas i facklorna ändras. Om förbättringen införs i hyttgasnätet minskas förlusterna av hyttgas och elproduktionen i kraftverket kan ökas.</p>
20

Validering i verkligheten : Utvärdering av Handbok - validering av kontrollrumsändringar

Lindh, Petter January 2004 (has links)
<p>Detta arbete är en utvärdering av metoden i och utformningen av Handbok – Validering av kontrollrumsändringar. SwedPower har producerat Handboken för Statens kärnkraftsinspektion och kärnkraftverken. Handboken har funnits i några år och SKI hade en önskan om att den skulle utvärderas. Handboken skrevs som ett hjälpmedel för valideringspersonal, för att åstadkomma ett standardiserat, väl fungerande tillvägagångssätt för validering. Att metoden är standardiserad är viktigt för att det skall gå att göra jämförelser mellan olika valideringar. Handboken skall kunna användas som referensverk av personal på SKI och ute på kärnkraftverken för att öka insynsmöjligheten, samt att förenkla förståelsen för och deltagande i valideringen av kontrollrum. För att lyckas med ovanstående skall Handboken vara praktisk tillämpbar. Den skall också vara inriktad på att kunna validera ändringar till skillnad från att validera något helt nytt. </p><p>Arbetet är en litteraturstudie som bygger på validerings- och metodlitteratur. I arbetet diskuteras begreppet validering och Handbokens definition av det. Tyngdpunkten i uppsatsen ligger i en genomgång av hur en validering enligt Handboken ser ut. Där redovisas varje delmetod och förslag ges på lämpliga förändringar. Även för- och nackdelar med Handbokens utformning diskuteras. Sist kommer ett resultat- och diskussionsavsnitt med resultatet av utvärderingen och övriga tankar och idéer som rör validering och Handboken. </p><p>Resultatet av utvärderingen är att Handboken uppfyller målen att vara praktisk och avsedd för ändringar, men att utformning och beskrivningar på sina ställen behöver modifieras. Uppsatsen ger förslag på modifieringar och vilka förbättringar dessa leder till.</p>

Page generated in 0.0739 seconds