• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 2
  • Tagged with
  • 36
  • 14
  • 13
  • 13
  • 12
  • 12
  • 10
  • 10
  • 9
  • 8
  • 7
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Análise tomográfica quantitativa linear de espessuras ósseas alveolares com vistas ao diagnóstico em ortodontia - Proposta de método / A quantitative linear tomographic analisys of the alveolar bone thicknesses and its implications to diagnosis in Orthodontics A method proposal

Silva, Siddhartha Uhrigshardt 01 June 2012 (has links)
O objetivo principal desta pesquisa foi justificar a proposta de utilização de um novo método tomográfico (cone beam) de avaliação das espessuras ósseas alveolares, maxilares e mandibulares, por meio de testes objetivos das Condições de Repetitividade e de Precisão Intermediária associadas à variação intra e interoperadores, e conforme a utilização de programa computacional independente (AutoCAD®) para a realização das medições, aplicadas à sequência do Procedimento Operacional Padrão (POP) definido para este experimento. A Fase I da pesquisa registrou os critérios de obtenção da qualidade final das imagens tomográficas definitivas, a partir de equipamento iCAT® (Imaging Sciences International, Hatfield, Pa), com parâmetros de aquisição de 120KVp, 37,7mA e 26,9s, e considerando FOV cilíndrico de 13cm e matriz de 512x512 pixels. A resolução do voxel foi de 0,25mm; A Fase II registrou os critérios exploratórios relativos às condições operacionais do software de visualização, registro (inspeção e identificação) e medição das grandezas selecionadas. A Fase III registrou a realização dos testes de repetitividade e de reprodutibilidade das medidas. Um total de 72 grandezas lineares foram previamente definidas e metodologicamente testadas em sua qualidade de inspeção, identificação e medição, a partir da avaliação de sete (7) operadores independentes, cinco dos quais eram especialistas e com Mestrado Acadêmico em Ortodontia pela FOUSP e, o outro, especialista em Radiologia Odontológica e Doutor em Diagnóstico Bucal (FOUSP). Os examinadores foram previamente instruídos, calibrados e treinados considerando os requerimentos necessários à execução dos testes propostos. O protocolo de pesquisa foi aprovado pelo Comitê de Ética em Pesquisa da Faculdade de Odontologia da Universidade de São Paulo (Parecer CAAE 0120.0.017.000-11). A análise estatística dependeu da utilização de Modelo de Componentes de Variância (hierárquico), e foram consideradas como fontes de variação: as medidas, efetuadas por um mesmo operador ou por diferentes operadores; a face considerada, vestibular ou lingual/palatina; os locais (três níveis de espessura óssea alveolar) em cada uma das faces e, ainda, os diferentes dentes. Esta análise foi realizada de forma separada para mandíbula e maxila. Valores de p<0,05 indicaram significância estatística. Os resultados indicaram significativa confiabilidade geral no método proposto, considerando a Condição de Repetitividade, com apenas 0,24% da variabilidade maxilar total atribuível a um único operador, e mandibular de 0,53%; e com valores expressivos relativos às incertezas de medida maxilares (0,156mm) e mandibulares (0,091mm), desse modo atestando significativa consistência interna (repetibilidade) do método. Os testes da Condição de Precisão Intermediária também indicaram significativa confiabilidade geral no método proposto, com apenas 1,52% da variabilidade total mandibular atribuível à participação de diversos operadores, e maxilar de 0,25%; e com valores também expressivos relativos às incertezas de medida mandibulares (0,149mm) e maxilares (0,158mm), desse modo atestando significativa condição final de reprodutibilidade. Conclui-se que a utilização de imagens provenientes de tomógrafo iCAT®, conforme indicação de resolução de imagem com voxel de 0,25mm, em humanos vivos e a partir de cortes trans-axiais sistematicamente operacionalizados com auxílio de Software AutoCAD®, propicia a geração de condições metodológicas suficientemente favoráveis à obtenção de mapeamento quantitativo linear de espessuras ósseas alveolares, vestibulares e palatinas/linguais, tanto para a maxila quanto para a mandíbula. / This research aimed to justify the proposed use of a new tomography method (cone beam) in the clinical assessment of alveolar, maxillary and mandibular bone width, through objective tests of the Conditions of Repetitiveness and Intermediate Precision associated with intra- and inter-operator variation, using the independent computer program (AutoCAD®) for the execution of the measurements according to the Standard Operating Procedure (SOP) sequence defined for this experiment. Phase I of the research recorded the criteria for obtaining the final quality of the tomography images, using iCAT® (Imaging Sciences International, Hatfield, Pa, USA) equipment with acquisition parameters 120KVp, 37.7mA, and 26.9s, and considering cilindric field-of-view (FOV) of 13cm and 512x512 pixels matrix. The voxel resolution was 0.25mm. Phase II recorded the exploratory criteria relative to the operational conditions of the visualization software, registry (visual inspection and landmark identification) and measurement of the selected magnitudes. Phase III recorded the tests of repeatability and reproducibility of the measurements. A total of 72 linear magnitudes were previously defined and methodologically tested for their quality of inspection, identification and measurement, based on assessment by seven (7) independent operators, five of whom were specialists, with masters degrees in Orthodontics from FOUSP; and the other, a specialist in Dental Radiology and Doctor of Oral Diagnosis (FOUSP). The examiners were previously instructed, calibrated and trained according to the requirements for performing the proposed tests. The research protocol was approved by the Committee for Ethics in Research of the Faculty of Dentistry at the University of São Paulo (Protocol # 102/11-CAAE 0120.0.017.000-11). Statistical analysis used the (hierarchical) Components of Variation Model, and the sources of variation were considered to be: the measurements, made by the same operator or by different operators; the face considered, whether vestibular or lingual/palatal; the locations (three levels of alveolar bone thickness) in each of the faces and, also, the different teeth. This analysis was carried out separately for the mandible and the maxilla. Values of p<0.05 indicated statistical significance. The results indicated overall significant reliability in the proposed method considering the Condition of Repetitiveness, with only 0.24% of total maxillary, and 0.53% of mandibular, variability attributable to a single operator; and with expressive values relative to measurement uncertainties of maxillary (0.156 mm) and mandibular (0.091mm) averages, thereby attesting to significant internal consistency (\"repeatability\") of the method. Tests for the Condition of Intermediate Precision also indicated overall significant reliability of the proposed method, with only 1.52% total mandibular, and 0.25% maxillary, variability attributable to the participation of the various operators; and, also, with expressive values relative to measurement uncertainties of mandibular (0.149mm) and maxillary (0.158mm) averages, thereby attesting to the significant final condition of reproducibility. It is concluded that the use of images from iCAT® tomography, as indicated by image resolution with voxels of 0.25mm, in live humans and from transaxial cuts performed systematically with the help of AutoCAD® Software, provides methodological conditions sufficiently favorable for obtaining linear quantitative mapping of alveolar, vestibular and palatal/lingual bone thicknesses, for both the maxillary and mandibular dental arches.
32

Estudo da atividade quimioprotetora in vitro e in vivo da Eugenia dysenterica dc. (Myrtaceae) após exposição ao cromo hexavalente / Study of in vitro and in vivo chemoprotective activity of Eugenia dysenterica DC. (Myrtaceae) followed by exposure to hexavalent chromium

Marcelino, Renato Ivan de Ávila 19 April 2013 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2014-11-24T12:08:05Z No. of bitstreams: 2 Dissertação - Renato Ivan de Ávila Marcelino - 2013.pdf: 1307159 bytes, checksum: 353b525742af80ec75afbd4c58f79c96 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2014-11-24T14:01:41Z (GMT) No. of bitstreams: 2 Dissertação - Renato Ivan de Ávila Marcelino - 2013.pdf: 1307159 bytes, checksum: 353b525742af80ec75afbd4c58f79c96 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-11-24T14:01:41Z (GMT). No. of bitstreams: 2 Dissertação - Renato Ivan de Ávila Marcelino - 2013.pdf: 1307159 bytes, checksum: 353b525742af80ec75afbd4c58f79c96 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-04-19 / Hexavalent chromium [Cr(VI)] is a toxic metal that triggers toxicity events in the body, penetrating cell membranes and increasing reactive oxygen species (ROS). These products, in turn, damage cellular macromolecules, inhibiting their functions and enhancing cell death via apoptosis. Therefore, it has been suggested that the use of antioxidants can minimize the damage induced by this metal. In this context, the Eugenia dysenterica DC. (Myrtaceae) plant species, native from Cerrado biome, has been studied because it presents high levels of polyphenols, substances with known antioxidant potential. Moreover, it is traditionally used in folk medicine and presents food and economic importance. In this work, in vitro and in vivo effects of the Eugenia dysenterica DC. leaf hydroalcoholic extract (EDE) on AMJ2-C11 cell line and mice exposed to Cr(VI), respectively, were investigated. In parallel, the antioxidant activity of EDE was also investigated by the methods of 2,2-Diphenyl-1-picrylhydrazyl (DPPH•) free radical capturing and co-oxidation of β-caroteno/linoleic acid. In vitro, pre-treatment of AMJ2-C11 cells with EDE (20, 40 ou 80 μg/mL) followed by exposure to Cr(VI) (100, 250 ou 500 μM) resulted in a concentration-dependent increase of cell viability. Furthermore, mechanistic studies of flow cytometry (cell cycle, annexin V, active caspases, ROS and rhodamine 123) and cell morphology showed that the EDE protected the cells from apoptosis triggered by Cr(VI), and reduced the ROS intracellular levels and prevented the loss of mitochondrial membrane potential. Additionally, significant antioxidant potential of EDE was observed. In vivo, prophylactic treatment for 10 days with EDE (50, 100 ou 200 mg/kg/day) and subsequent exposure to a sublethal dose of Cr(VI) (30 mg/kg) induced a decrease in Cr levels in the kidneys, liver and plasm, besides preventing liver and kidney changes caused by this metal. Moreover, treatment of animals with EDE (50, 100, 125, 200, 250 ou 500 mg/kg/day) followed by exposure to a lethal dose of Cr(VI) (50 mg/kg) induced an increase in the survival of exposed animals, especially at the doses of 50, 100 and 125 mg/kg. Therefore, the present study demonstrated that the EDE showed in vitro and in vivo effect against Cr(VI)-induced oxidative toxicity. / O cromo hexavalente [Cr(VI)] é um metal tóxico capaz de desencadear eventos toxicológicos no organismo, pois ultrapassa as membranas celulares e promove o aumento da produção de espécies reativas de oxigênio (ERO). Esses produtos, por sua vez, danificam as macromoléculas celulares, inibindo suas funções e favorecendo a morte celular por apoptose. Em vista disso, acredita-se que o uso de antioxidantes pode minimizar os danos induzidos por este metal. Nesse contexto, a espécie vegetal Eugenia dysenterica DC. (Myrtaceae), nativa do bioma Cerrado, tem sido estudada por apresentar altos níveis de polifenóis, substâncias que reconhecidamente têm potencial antioxidante. Ademais, é tradicionalmente utilizada na medicina popular e apresenta importância alimentar e econômica. Assim, neste trabalho, os efeitos in vitro e in vivo do extrato hidroalcoólico das folhas da Eugenia dysenterica (EED) sobre a linhagem celular AMJ2-C11 e em camundongos expostos ao Cr(VI), respectivamente, foram investigados. Em paralelo, a atividade antioxidante do EED também foi investigada através dos métodos de captura do radical livre 2,2-difenil-1-picrilidrazila (DPPH•) e da co-oxidação do β-caroteno/ácido linoléico. In vitro, o pré-tratamento das células AMJ2-C11 com EED (20, 40 ou 80 μg/mL) seguido de exposição ao Cr(VI) (100, 250 ou 500 μM) resultou em um aumento da viabilidade celular, de forma concentração dependente. Além disso, estudos mecanísticos utilizando citômetro de fluxo (ciclo celular, anexina V, caspases ativas, ERO e rodamina 123) e de morfologia celular evidenciaram que o EED protegeu as células da apoptose desencadeada pelo Cr(VI), além de reduzir os níveis intracelulares de ERO e impedir a perda do potencial de membrana mitocondrial. Adicionalmente, foi observado relevante potencial antioxidante do EED. In vivo, o tratamento profilático por 10 dias com EED (50, 100 ou 200 mg/kg/dia) e subsequente exposição a uma dose subletal de Cr(VI) (30 mg/kg) promoveu redução dos níveis de Cr nos rins, fígado e plasma, além de prevenir alterações hepáticas e renais causadas por esse metal. Além disso, o tratamento dos animais com EED (50, 100, 125, 200, 250 ou 500 mg/kg/dia) seguido de exposição a uma dose letal de Cr(VI) (50 mg/kg) promoveu um aumento da sobrevida dos animais expostos, principalmente nas doses de 50, 100 e 125 mg/kg. Por conseguinte, o presente estudo demonstrou que o EED
33

Análise tomográfica quantitativa linear de espessuras ósseas alveolares com vistas ao diagnóstico em ortodontia - Proposta de método / A quantitative linear tomographic analisys of the alveolar bone thicknesses and its implications to diagnosis in Orthodontics A method proposal

Siddhartha Uhrigshardt Silva 01 June 2012 (has links)
O objetivo principal desta pesquisa foi justificar a proposta de utilização de um novo método tomográfico (cone beam) de avaliação das espessuras ósseas alveolares, maxilares e mandibulares, por meio de testes objetivos das Condições de Repetitividade e de Precisão Intermediária associadas à variação intra e interoperadores, e conforme a utilização de programa computacional independente (AutoCAD®) para a realização das medições, aplicadas à sequência do Procedimento Operacional Padrão (POP) definido para este experimento. A Fase I da pesquisa registrou os critérios de obtenção da qualidade final das imagens tomográficas definitivas, a partir de equipamento iCAT® (Imaging Sciences International, Hatfield, Pa), com parâmetros de aquisição de 120KVp, 37,7mA e 26,9s, e considerando FOV cilíndrico de 13cm e matriz de 512x512 pixels. A resolução do voxel foi de 0,25mm; A Fase II registrou os critérios exploratórios relativos às condições operacionais do software de visualização, registro (inspeção e identificação) e medição das grandezas selecionadas. A Fase III registrou a realização dos testes de repetitividade e de reprodutibilidade das medidas. Um total de 72 grandezas lineares foram previamente definidas e metodologicamente testadas em sua qualidade de inspeção, identificação e medição, a partir da avaliação de sete (7) operadores independentes, cinco dos quais eram especialistas e com Mestrado Acadêmico em Ortodontia pela FOUSP e, o outro, especialista em Radiologia Odontológica e Doutor em Diagnóstico Bucal (FOUSP). Os examinadores foram previamente instruídos, calibrados e treinados considerando os requerimentos necessários à execução dos testes propostos. O protocolo de pesquisa foi aprovado pelo Comitê de Ética em Pesquisa da Faculdade de Odontologia da Universidade de São Paulo (Parecer CAAE 0120.0.017.000-11). A análise estatística dependeu da utilização de Modelo de Componentes de Variância (hierárquico), e foram consideradas como fontes de variação: as medidas, efetuadas por um mesmo operador ou por diferentes operadores; a face considerada, vestibular ou lingual/palatina; os locais (três níveis de espessura óssea alveolar) em cada uma das faces e, ainda, os diferentes dentes. Esta análise foi realizada de forma separada para mandíbula e maxila. Valores de p<0,05 indicaram significância estatística. Os resultados indicaram significativa confiabilidade geral no método proposto, considerando a Condição de Repetitividade, com apenas 0,24% da variabilidade maxilar total atribuível a um único operador, e mandibular de 0,53%; e com valores expressivos relativos às incertezas de medida maxilares (0,156mm) e mandibulares (0,091mm), desse modo atestando significativa consistência interna (repetibilidade) do método. Os testes da Condição de Precisão Intermediária também indicaram significativa confiabilidade geral no método proposto, com apenas 1,52% da variabilidade total mandibular atribuível à participação de diversos operadores, e maxilar de 0,25%; e com valores também expressivos relativos às incertezas de medida mandibulares (0,149mm) e maxilares (0,158mm), desse modo atestando significativa condição final de reprodutibilidade. Conclui-se que a utilização de imagens provenientes de tomógrafo iCAT®, conforme indicação de resolução de imagem com voxel de 0,25mm, em humanos vivos e a partir de cortes trans-axiais sistematicamente operacionalizados com auxílio de Software AutoCAD®, propicia a geração de condições metodológicas suficientemente favoráveis à obtenção de mapeamento quantitativo linear de espessuras ósseas alveolares, vestibulares e palatinas/linguais, tanto para a maxila quanto para a mandíbula. / This research aimed to justify the proposed use of a new tomography method (cone beam) in the clinical assessment of alveolar, maxillary and mandibular bone width, through objective tests of the Conditions of Repetitiveness and Intermediate Precision associated with intra- and inter-operator variation, using the independent computer program (AutoCAD®) for the execution of the measurements according to the Standard Operating Procedure (SOP) sequence defined for this experiment. Phase I of the research recorded the criteria for obtaining the final quality of the tomography images, using iCAT® (Imaging Sciences International, Hatfield, Pa, USA) equipment with acquisition parameters 120KVp, 37.7mA, and 26.9s, and considering cilindric field-of-view (FOV) of 13cm and 512x512 pixels matrix. The voxel resolution was 0.25mm. Phase II recorded the exploratory criteria relative to the operational conditions of the visualization software, registry (visual inspection and landmark identification) and measurement of the selected magnitudes. Phase III recorded the tests of repeatability and reproducibility of the measurements. A total of 72 linear magnitudes were previously defined and methodologically tested for their quality of inspection, identification and measurement, based on assessment by seven (7) independent operators, five of whom were specialists, with masters degrees in Orthodontics from FOUSP; and the other, a specialist in Dental Radiology and Doctor of Oral Diagnosis (FOUSP). The examiners were previously instructed, calibrated and trained according to the requirements for performing the proposed tests. The research protocol was approved by the Committee for Ethics in Research of the Faculty of Dentistry at the University of São Paulo (Protocol # 102/11-CAAE 0120.0.017.000-11). Statistical analysis used the (hierarchical) Components of Variation Model, and the sources of variation were considered to be: the measurements, made by the same operator or by different operators; the face considered, whether vestibular or lingual/palatal; the locations (three levels of alveolar bone thickness) in each of the faces and, also, the different teeth. This analysis was carried out separately for the mandible and the maxilla. Values of p<0.05 indicated statistical significance. The results indicated overall significant reliability in the proposed method considering the Condition of Repetitiveness, with only 0.24% of total maxillary, and 0.53% of mandibular, variability attributable to a single operator; and with expressive values relative to measurement uncertainties of maxillary (0.156 mm) and mandibular (0.091mm) averages, thereby attesting to significant internal consistency (\"repeatability\") of the method. Tests for the Condition of Intermediate Precision also indicated overall significant reliability of the proposed method, with only 1.52% total mandibular, and 0.25% maxillary, variability attributable to the participation of the various operators; and, also, with expressive values relative to measurement uncertainties of mandibular (0.149mm) and maxillary (0.158mm) averages, thereby attesting to the significant final condition of reproducibility. It is concluded that the use of images from iCAT® tomography, as indicated by image resolution with voxels of 0.25mm, in live humans and from transaxial cuts performed systematically with the help of AutoCAD® Software, provides methodological conditions sufficiently favorable for obtaining linear quantitative mapping of alveolar, vestibular and palatal/lingual bone thicknesses, for both the maxillary and mandibular dental arches.
34

Efeitos da acupuntura sobre os pacientes com asma leve e moderada persistentes: um estudo randomizado, controlado e cruzado / Effects of acupuncture on patients with mild to moderate persistent asthma: a randomized, controlled, crossover

Pai, Hong Jin 11 March 2014 (has links)
Introdução: Este estudo foi realizado com o intuito de avaliar efeitos da acupuntura sobre os pacientes com asma leve e moderada persistentes com o uso de beta-2 agonista ou corticoide inalatório. Métodos e casuística: Trata-se de um estudo prospectivo, duplo-cego, randomizado e cruzado com dois braços. Os 74 pacientes com diagnóstico de asma leve/moderada, de acordo com a classificação de GINA 2002/2003, foram divididos em dois grupos, sendo 31 do Grupo I, e 43 do Grupo II inicialmente. Foram realizadas consultas médicas e exames que incluíram espirometria, citologia de escarro induzido, NO expirado, preenchimento de escala de sintoma, questionários de qualidade de vida de asma e de SF 36, e realização de peak-flow, dependendo da Fase do protocolo. A Fase I constituiu-se dos exames pré-intervenção. Na Fase II, foram realizadas 10 sessões de Acupuntura Real no Grupo I e 10 sessões de Acupuntura Sham no Grupo II, na Fase III, houve 4 semana de washout, na Fase IV, houve a troca de técnicas de acupuntura, sendo uma sessão por semana e, na Fase V, realização dos exames. Resultados: Não há diferença nos critérios de avaliação no pré-tratamento entre dois grupos, com exceção de maior celularidade inflamatória no Grupo II. No entanto, houve uma redução significativa de eosinófilos (p = 0,035) e neutrófilos (p = 0,047), e aumento de macrófagos (p = 0,001), melhora da medida de volume do peak-flow (p = 0,01) na fase IV do Grupo II. No Grupo I, na avaliação de escala de sintomas diária, havia menor uso de medicação de resgate (p = 0,043) na Fase II, e, depois de receber a Acupuntura Sham na Fase IV, havia menos tosse (p = 0,007), menos chiado (p = 0,037), menos dispneia (p < 0,001) e menor uso de medicação de resgate (p < 0,001). No Grupo II, após receber o tratamento com a Acupuntura Sham na Fase II, houve diminuição de tosse (p = 0,037), de chiado (p = 0,013) e de dispneia (p = 0,014), e, na Fase IV, havia menos tosse (p = 0,040), sibilos (p = 0,012), dispneia (p < 0,001) e menos despertares noturnos (p = 0,009). Nos questionários de qualidade de vida de asma e de SF 36, foram encontrados alguns aspectos de melhora significantes na Acupuntura Sham dos dois grupos em relação à Fase I, mas os resultados da Acupuntura Real tiveram maiores índices de melhora em relação aos resultados da Acupuntura Sham nos dois grupos. Mas não há diferença significativa entre os dois na qualidade de vida de SF 36. Entretanto, não houve alteração de avaliação de espirometria e de óxido nítrico expirado. Conclusão: Este estudo demonstrou que o uso de Acupuntura Real num grupo de pacientes com a celularidade mais inflamatória teve melhor resultados de sintomas diários, tais como dispneia e despertar noturno, de medida de volume de peak-flow matutina, e de avaliação de qualidade de vida em asma e SF36, além da diminuição quantitativa de neutrófilos e de eosinófilos, com aumento de macrófagos, que justificam os efeitos anti-inflamatórios e imunitários. A acupuntura é uma terapia segura, não havendo nenhum efeito colateral observado neste projeto que possa interferir com a vida cotidiana e pode ser de grande auxílio no alívio de sintomas, com melhora de qualidade de vida e, possivelmente, pode ter uma ação na modulação do processo inflamatório de vias aéreas / Introduction: This survey has been conducted in order to evaluate the effects of acupuncture in patients with persistent mild and moderate asthma (according to GINA criteria 2003), using beta agonist and/or inhaled glucocorticoid. Methods and patients: This is a prospective, double blinded, randomized and cross-over study with two branches: 74 patients diagnosed with mild and moderate asthma were divided into two groups: Group I with 31, initiating with real acupuncture and Group II, starting with sham acupuncture. Medical interview and laboratory tests including spirometry, induced sputum citology, exhaled NO measurement, quality of life questionnaire (SF-36 and QQL), besides, daily symptom scores and measurement of peak-flow were performed, in the beginning of the study, and in the end of each phase of treatment. Phase I: laboratory tests and other qualitative measurements. There were 10 real acupuncture weekly sessions to Group I and 10 sham acupuncture sessions to Group II in Phase II. On the other hand, in the Phase IV, there was an exchange between Group I and Group II, which was receiving real acupuncture started to receive sham, and vice-versa, the number of sessions remained the same (10 weekly sessions). Phase III, during the interval between Phase II and Phase IV, there was an interval of 4 weeks of washout. Phase V: laboratory tests and other qualitative measurements. Results: There was no difference beween both the groups in all criteria of evaluation pré treatment, with only na exception: in the Group II there was large inflammatory cell counts. However, there was a significant reduction in eosinophils (p = 0.035) and neutrophils (p = 0.047), and increase of macrophages (p = 0.001), improved peak-flow measurement in the morning (p = 0.01) in Group II (started with sham) in Phase IV. In Daily Symptons Score, there was a significant reduction in use of rescue medication (p = 0.043) in Group I (real acupuncture) in Phase II and after received sham acupuncture (Phase IV), there were less cough (p = 0.007), less wheezing (p = 0.037), less dyspnea (p < 0.001) e less use of rescue medication (p < 0.001). In Group II, after received sham (Phase II), there were less cough (p = 0.037), less wheezing (p = 0.013) and less dyspnea (p = 0.014). In Phase IV, less cough (p = 0.040), wheezing (p = 0.012), dyspnea (p < 0.001) and less nocturnal awakening (p = 0.009). In the questionnaires of quality of life SF-36 and QQL, several domains were found to be improved after received sham acupuncture in both groups, comparing phase II against phase I, but the results found after received real acupuncture were better than sham in both groups. Although there was no statistic difference between both groups. However, there was no difference in exhaled NO and spirometry measurement. Conclusion: This survey demonstrated that the use of real acupuncture in a group of patients with large inflammatory cells counts could have contributed to reduce symptoms, improve quality of life, improved peak-flow measurement in the morning and reduced inflammatory cells count in induced sputum, therefore, acupuncture is a safe healing techniques, presented no adverse effects observed in this study, and could of great help in treatment of patients with mild and moderate asthma
35

Efeitos da acupuntura sobre os pacientes com asma leve e moderada persistentes: um estudo randomizado, controlado e cruzado / Effects of acupuncture on patients with mild to moderate persistent asthma: a randomized, controlled, crossover

Hong Jin Pai 11 March 2014 (has links)
Introdução: Este estudo foi realizado com o intuito de avaliar efeitos da acupuntura sobre os pacientes com asma leve e moderada persistentes com o uso de beta-2 agonista ou corticoide inalatório. Métodos e casuística: Trata-se de um estudo prospectivo, duplo-cego, randomizado e cruzado com dois braços. Os 74 pacientes com diagnóstico de asma leve/moderada, de acordo com a classificação de GINA 2002/2003, foram divididos em dois grupos, sendo 31 do Grupo I, e 43 do Grupo II inicialmente. Foram realizadas consultas médicas e exames que incluíram espirometria, citologia de escarro induzido, NO expirado, preenchimento de escala de sintoma, questionários de qualidade de vida de asma e de SF 36, e realização de peak-flow, dependendo da Fase do protocolo. A Fase I constituiu-se dos exames pré-intervenção. Na Fase II, foram realizadas 10 sessões de Acupuntura Real no Grupo I e 10 sessões de Acupuntura Sham no Grupo II, na Fase III, houve 4 semana de washout, na Fase IV, houve a troca de técnicas de acupuntura, sendo uma sessão por semana e, na Fase V, realização dos exames. Resultados: Não há diferença nos critérios de avaliação no pré-tratamento entre dois grupos, com exceção de maior celularidade inflamatória no Grupo II. No entanto, houve uma redução significativa de eosinófilos (p = 0,035) e neutrófilos (p = 0,047), e aumento de macrófagos (p = 0,001), melhora da medida de volume do peak-flow (p = 0,01) na fase IV do Grupo II. No Grupo I, na avaliação de escala de sintomas diária, havia menor uso de medicação de resgate (p = 0,043) na Fase II, e, depois de receber a Acupuntura Sham na Fase IV, havia menos tosse (p = 0,007), menos chiado (p = 0,037), menos dispneia (p < 0,001) e menor uso de medicação de resgate (p < 0,001). No Grupo II, após receber o tratamento com a Acupuntura Sham na Fase II, houve diminuição de tosse (p = 0,037), de chiado (p = 0,013) e de dispneia (p = 0,014), e, na Fase IV, havia menos tosse (p = 0,040), sibilos (p = 0,012), dispneia (p < 0,001) e menos despertares noturnos (p = 0,009). Nos questionários de qualidade de vida de asma e de SF 36, foram encontrados alguns aspectos de melhora significantes na Acupuntura Sham dos dois grupos em relação à Fase I, mas os resultados da Acupuntura Real tiveram maiores índices de melhora em relação aos resultados da Acupuntura Sham nos dois grupos. Mas não há diferença significativa entre os dois na qualidade de vida de SF 36. Entretanto, não houve alteração de avaliação de espirometria e de óxido nítrico expirado. Conclusão: Este estudo demonstrou que o uso de Acupuntura Real num grupo de pacientes com a celularidade mais inflamatória teve melhor resultados de sintomas diários, tais como dispneia e despertar noturno, de medida de volume de peak-flow matutina, e de avaliação de qualidade de vida em asma e SF36, além da diminuição quantitativa de neutrófilos e de eosinófilos, com aumento de macrófagos, que justificam os efeitos anti-inflamatórios e imunitários. A acupuntura é uma terapia segura, não havendo nenhum efeito colateral observado neste projeto que possa interferir com a vida cotidiana e pode ser de grande auxílio no alívio de sintomas, com melhora de qualidade de vida e, possivelmente, pode ter uma ação na modulação do processo inflamatório de vias aéreas / Introduction: This survey has been conducted in order to evaluate the effects of acupuncture in patients with persistent mild and moderate asthma (according to GINA criteria 2003), using beta agonist and/or inhaled glucocorticoid. Methods and patients: This is a prospective, double blinded, randomized and cross-over study with two branches: 74 patients diagnosed with mild and moderate asthma were divided into two groups: Group I with 31, initiating with real acupuncture and Group II, starting with sham acupuncture. Medical interview and laboratory tests including spirometry, induced sputum citology, exhaled NO measurement, quality of life questionnaire (SF-36 and QQL), besides, daily symptom scores and measurement of peak-flow were performed, in the beginning of the study, and in the end of each phase of treatment. Phase I: laboratory tests and other qualitative measurements. There were 10 real acupuncture weekly sessions to Group I and 10 sham acupuncture sessions to Group II in Phase II. On the other hand, in the Phase IV, there was an exchange between Group I and Group II, which was receiving real acupuncture started to receive sham, and vice-versa, the number of sessions remained the same (10 weekly sessions). Phase III, during the interval between Phase II and Phase IV, there was an interval of 4 weeks of washout. Phase V: laboratory tests and other qualitative measurements. Results: There was no difference beween both the groups in all criteria of evaluation pré treatment, with only na exception: in the Group II there was large inflammatory cell counts. However, there was a significant reduction in eosinophils (p = 0.035) and neutrophils (p = 0.047), and increase of macrophages (p = 0.001), improved peak-flow measurement in the morning (p = 0.01) in Group II (started with sham) in Phase IV. In Daily Symptons Score, there was a significant reduction in use of rescue medication (p = 0.043) in Group I (real acupuncture) in Phase II and after received sham acupuncture (Phase IV), there were less cough (p = 0.007), less wheezing (p = 0.037), less dyspnea (p < 0.001) e less use of rescue medication (p < 0.001). In Group II, after received sham (Phase II), there were less cough (p = 0.037), less wheezing (p = 0.013) and less dyspnea (p = 0.014). In Phase IV, less cough (p = 0.040), wheezing (p = 0.012), dyspnea (p < 0.001) and less nocturnal awakening (p = 0.009). In the questionnaires of quality of life SF-36 and QQL, several domains were found to be improved after received sham acupuncture in both groups, comparing phase II against phase I, but the results found after received real acupuncture were better than sham in both groups. Although there was no statistic difference between both groups. However, there was no difference in exhaled NO and spirometry measurement. Conclusion: This survey demonstrated that the use of real acupuncture in a group of patients with large inflammatory cells counts could have contributed to reduce symptoms, improve quality of life, improved peak-flow measurement in the morning and reduced inflammatory cells count in induced sputum, therefore, acupuncture is a safe healing techniques, presented no adverse effects observed in this study, and could of great help in treatment of patients with mild and moderate asthma
36

[pt] ESTUDO DE VIGAS DE AÇO COM ABERTURAS DE ALMA TIPO ALVEOLAR, LITZKA E VIGAS EXPANDIDAS EM ALTURA / [en] STUDY OF STEEL BEAMS WITH WEB OPENINGS INCLUDING CELLULAR, LITZKA AND DEPTH-EXPANDED BEAMS

JORGE AUGUSTO WISSMANN 30 October 2017 (has links)
[pt] Estruturas cada vez mais esbeltas têm sido usadas para otimizar edifícios de grande porte e reduzir custos, inclui-se nisto o pé-direito das edificações e portanto a altura das vigas. Grandes vãos são cada vez mais comuns, principalmente quando se utiliza aço em edificações, gerando então amplos espaços de serviço em uma direção, mas obstáculos na outra pela continuidade das vigas. A utilização de aberturas na alma das vigas para passagem de tubulações de ar-condicionado, incêndio, etc., evita um acréscimo na altura. Em consequência há uma grande diminuição da capacidade resistente nestes elementos estruturais que dependem diretamente da forma, do tamanho e da posição destas aberturas. A presente dissertação descreve alguns métodos construtivos de aberturas em almas de vigas de aço, cálculos de dimensionamentos e normas relacionadas. Alguns estudos numéricos com aplicações do método dos elementos finitos foram realizados investigando: angulação de aberturas hexagonais, vigas com três aberturas nos terços médios, vigas casteladas (tipo Litzka, com quantidades diferentes de aberturas), vigas expandidas em altura e uma viga Litzka Expandida. Para tal, utilizou-se de seis perfis de uso prático e comparando-os entre estas alternativas descritas. A viga Litzka Expandida se destacou em resistência quando comparada com outros métodos de fabricação, como também pelo menor peso linear, praticidade na fabricação e posicionamento das aberturas. / [en] More slender structures are used in order to reduce costs, floors depht and floor to ceiling clear heights. Steel construction and composite construction for buildings often employs long spans for beams and girders, offering service room between beams in one direction only. The use of web openings for passage of service ducts avoids increasing the depth of construction. Beams with web openings have reductions on flexural and shear resistances depending on the geometry, size and position of such openings on the beam. This dissertation presents some construction methods of beam web openings, analysis and design recommendations, related standards and codes. Some numerical studies by the finite elements method were carried out and results are presented for: type of openings, number and spacing of openings, castelled beams (Litzka type and nonuniform distribution of openings) and expanded in depth beams. For this purpose, six commonly used profiles were used for testing the described web openings solutions. Some comparison results are presented. The Litzka type of web expanded beam presented the best performance in terms of strength, easy of fabrication and reduction of material costs.

Page generated in 0.0618 seconds