• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 86
  • 3
  • Tagged with
  • 89
  • 89
  • 59
  • 59
  • 18
  • 12
  • 11
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Organização do Conhecimento na Ciência da Informação: uma análise métrica nos periódicos brasileiros (1972-2012) / Knowledge Organization in Information Science: a metric analysis in Brazilian journals (1972-2012)

Amorim Neto, Miguel Romeu 18 June 2013 (has links)
Submitted by Miguel R. Amorim Neto (miguel@sibi.ufrj.br) on 2016-03-24T22:22:57Z No. of bitstreams: 1 miguel.pdf: 4943130 bytes, checksum: 244096b1a54936c3f375faf419cf8fb9 (MD5) / Made available in DSpace on 2016-03-24T22:22:57Z (GMT). No. of bitstreams: 1 miguel.pdf: 4943130 bytes, checksum: 244096b1a54936c3f375faf419cf8fb9 (MD5) Previous issue date: 2013-06-18 / REUNI (MEC) / Investigação analítico-quali/quantitativa detectando o domínio de Organização do Conhecimento (OC) frente à produção brasileira de artigos de periódicos de Ciência da Informação a partir de levantamentos realizados na Base de Dados Referencial de Artigos de Periódico em Ciência da Informação. O objetivo geral da pesquisa é analisar comparativamente a ocorrência numérica absoluta e relativa de artigos de periódicos brasileiros da área de CI sobre a temática Organização do Conhecimento cobertos na base BRAPCI de 1972 a 2012 através de recortes temático-conceituais. Apresenta conceituações para a compreensão da Organização do Conhecimento, a partir da abordagem da Análise de Domínio de Hjørland e Albrechtsen (1995), a qual permitiu que fossem identificados os conceitos pertencentes da OC. Para atender aos objetivos de pesquisa, utilizaram-se técnicas quantitativas de avaliação da produção científica como método de análise dos dados recuperados na BRAPCI e análise qualitativa dos resultados. Estas sinalizaram que o Domínio de OC está em expansão no Brasil ao contrário do cenário internacional. / Investigation qualitative and quantitative analysis detecting the domain of Knowledge Organization front of the whole area of information science from surveys conducted in Referential Database Journal Articles in Information Science. The objective of the research is to analyze the occurrence numerical absolute and relative articles of Brazilian journals of information science on the topic covered in the Knowledge Organization based BRAPCI 1972-2012 through conceptual-themed cutouts. Presents concepts for understanding the Organization of Knowledge, from the approach of Domain Analysis of Hjørland and Albrechtsen (1995), which allowed them to be identified concepts of belonging OC. To meet the research objectives, we used quantitative techniques for assessing the scientific literature as a method of analyzing the data retrieved in BRAPCI and qualitative analysis. This signaled that the domain OC is expanding in Brazil unlike the international scene.
82

Mapeamento topológico virtual de neurônios proporcional às atividades eletrofisiológicas em matrizes de microeletrodos

Rodríguez, Eduardo Rafael Llapa 15 December 2015 (has links)
Submitted by Luciana Sebin (lusebin@ufscar.br) on 2016-10-05T18:08:34Z No. of bitstreams: 1 TeseERLR.pdf: 4461748 bytes, checksum: 2fe540767de5ff5f23af02775508026b (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-10-14T14:11:13Z (GMT) No. of bitstreams: 1 TeseERLR.pdf: 4461748 bytes, checksum: 2fe540767de5ff5f23af02775508026b (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-10-14T14:11:22Z (GMT) No. of bitstreams: 1 TeseERLR.pdf: 4461748 bytes, checksum: 2fe540767de5ff5f23af02775508026b (MD5) / Made available in DSpace on 2016-10-14T14:11:41Z (GMT). No. of bitstreams: 1 TeseERLR.pdf: 4461748 bytes, checksum: 2fe540767de5ff5f23af02775508026b (MD5) Previous issue date: 2015-12-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / This thesis combines image and signal processing to obtain virtual neuron distribution maps in a Microelectrode Array (MEA), which are devices designed for non-invasive electrophysiological signal recording for in vitro cultures of neuron cells. In the electrophysiological signal analysis, it is of interest the knowledge of the topological distribution of the cells along the MEA microelectrodes, but, usually the photographic images of the cell culture are not available. This doctoral work presents an approach to obtain the statistical topologic distribution of the neurons of an in vitro cell culture, denoted virtual distribution of neurons, from the electrophysiological signals. To certify that the statistical computation of the neuron counting is associated to each MEA microelectrode, it is used the ICA (Independent component Analysis) technique, for the separation of the neuron signals distributed throughout the MEA area, to obtain for each microelectrode, only the signals from its adjacent neurons. Assuming the hypothesis that the spontaneous neuron activities, spikes and bursts, are directly proportional to the neuron counting, it is realized the spike counting and burst counting, and it is assigned for each microelectrode, a number of neurons proportional to that numbers of activities. For the validation of the proposal, as well as for calibration of the system, to obtain the estimated number of neurons, it was used an experiment denoted 371, realized in Genoa University, Italy, in which it was recorded electrophysiological signals in 46 DIVs (Days In- Vitro), obtaining 20 minutes of recording in 25, 29, 32, 36, 39, 43, and 46 DIVs, and a set of photographic images in 38 DIV. Assuming that microelectrode neuron counting in the 38 DIV photographic image is proportional to the 39 DIV spontaneous electrophysiological activity signal recording, one day after the imaging, if was determined the neuron counting as function of the spontaneous electrophysiological activities recording, in a process denoted as calibration of the virtual number of neurons. The distance error from the neuron activities as function of the neuron counting in photographic image and in function of the recorded electrophysiological signals was calculated and compared for validation. In this way, it was possible to construct virtual topologic maps of neurons, proportional to the electrophysiological activities measured in 39 DIV, as a function of the spike and the burst countings. Comparing these two virtual maps, the spike counting virtual map was more close to the real neuron distributions viewed at the photographic image of 38 DIV. Also, the variance of the spike and burst counting along the 20 min of electrophysiological recording in a DIV, was calculated, and noted that the spike counting is more stable than burst counting. / Esta tese combina processamento de imagens e sinais, para a obtenção de uma distribuição virtual de neurônios em Matrizes de microeletrodos (Microelectrode Array, MEA), dispositivos projetados para o registro de sinais eletrofisiológicos de culturas de células neuronais, in-vitro, de forma não-invasiva. Na análise dos sinais eletrofisiológicos é de interesse o conhecimento da distribuição topológica das células ao longo dos microeletrodos, porém, nem sempre as imagens fotográficas das culturas são disponíveis. O presente trabalho apresenta uma metodologia de obtenção da distribuição topológica estatística dos neurônios numa cultura in-vitro, a partir dos sinais eletrofisiológicos. Para o cálculo estatístico do número de neurônios nessa distribuição topológica, é feito o uso da técnica de ICA (Independent Component Analysis), para obter os sinais relativos aos neurônios mais próximos para cada microeletrodo. Assumindo-se a hipótese de que as atividades eletrofisiológicas espontâneas dos neurônios, spikes e bursts, sejam diretamente proporcionais ao número de neurônios, realiza-se a contagem do número de spikes ou o número de bursts, e atribui-se o número de neurônios para cada microeletrodo, proporcionalmente à quantidade dessas atividades. Para a validação da proposta, foi utilizado um experimento, Experimento 371, realizado na Universidade de Gênova, Itália, em que foram registrados os sinais eletrofisiológicos ao longo de 46 DIVs (Dias In-Vitro), obtendo amostras de 20 minutos de registros para os 25, 29, 32, 36, 39, 43 e 46 DIVs, e um conjunto de imagens fotográficas da cultura no 38 DIV. Considerando-se que o número de neurônios associados a cada microeletrodo na imagem fotográfica no 38 DIV é proporcional à atividade eletrofisiológica espontânea dos neurônios, num registro realizado no 39 DIV, um dia após as fotos, foi feita uma regra de determinação do número virtual de neurônios em função das atividades eletrofisiológicas espontâneas medidas, denominada de calibração. O erro relativo à distância da atividade dos neurônios em relação à quantidade de neurônios na imagem fotográfica, e a atividade dos neurônios em função do registro de sinais eletrofisiológicos é calculado para comparação e validação. Dessa forma são construídos os mapas topológicos virtuais de neurônios proporcionais às atividades eletrofisiológicas medidas no 39 DIV, em função da quantidade de spikes e de bursts. O mapa obtido pela contagem de spikes se aproxima mais da distribuição real de neurônios vista na imagem fotográfica, do que o mapa obtido em função da contagem de bursts. No estudo de variância de atividades em função da contagem de spikes e bursts durante os 20 minutos de medidas num DIV, e constata-se que as atividades em contagem spikes é mais estável que em contagem de bursts.
83

Correlação de estrias de fadiga com espectro de cargas em liga de Al aeronáutica SAE-AMS 7475 T 7351. / Correlation of fatigue striation spacing to loading history in aeronautic Al alloy, AMS 7475 T7351.

Cassius Olivio Figueiredo Terra Ruchert 29 August 2003 (has links)
Este trabalho discutiu a relação entre o espaçamento inter-estrias , isto é, a taxa de propagação da trinca microscópica SL (local) e SP (projetada) e a taxa de propagação macroscópica , da/dN, obtido após o ensaio de propagação de trinca por fadiga. Corpos de prova compacto C(T) foram extraídos na orientação LT do centro de uma placa laminada de liga de alumínio SAE-AMS 7475 T7351 onde posteriormente foram realizados ensaios de fadiga sob carga ou &#916K constantes, à temperatura ambiente de acordo com a Norma ASTM-E647 (1993). Para o ensaio sob carga constante foram obtidos os dados do estágio II e III da curva da/dN vs. &#916K. Para o ensaio de fadiga sob &#916K constante, quatro níveis de &#916K foram utilizados com taxas de crescimento de trinca variando entre 0,15 à 2,4 &#956m/ciclo. Adicionalmente foram realizados ensaios de tenacidade à fratura, KIC nas direções LT e TL conforme a Norma ASTM-E1820 (1999). A análise fratográfica por microscopia eletrônica de varredura foi conduzida no ensaio de fadiga a &#916K constante para determinar os espaçamentos inter-estrias. As taxas de propagação macroscópica e microscópica foram comparadas e boas correlações foram obtidas para um intervalo entre 0,1 a 1,0 &#956m/ciclo. Através da técnica proposta por Berkovitz (1995), o espectro de carregamento foi estimado através da técnica de parametrização do fator K e os resultados foram comparados ao espectro de carregamento real imposto pela máquina de ensaio. Utilizando o espaçamento inter-estrias local, SL, e para valores de &#916K menores que 23 MPam 1/2 (região de Paris), a estimativa de carregamento exibiu um erro menor que 15%. As vidas estimadas em propagação fornecidas pelas taxas microscópicas de propagação de trinca foram comparadas à vida real de propagação obtida a partir da taxa de propagação de trinca macroscópica e o erro absoluto entre ambos os valores foi menor que 15,7 %. Estes resultados sugerem que a vida em fadiga e o espectro de carga podem ser adequadamente estimados utilizando o espaçamento inter-estrias local, SL. / This work discusses the relationship between striation spacing, i.e. the microscopic crack propagation rate, SL (local) e SP (projected), as measured in post-mortem fractographic inspection of fatigue fractured surfaces, and the macroscopic crack propagation rate, da/dN, as monitored during fatigue crack growth tests. Compact tensile specimens C(T) were extracted in LT orientation from the core of a laminated plate of a SAE-AMS 7475-T7351 Al alloy and subsequently fatigue tested either at constant load or at constant &#916K, at room temperature, according to ASTM-E647. For constant amplitude loading fatigue tests, da/dN- &#916K data points were obtained for Regions II and III of crack growth curve. For constant &#916K fatigue tests, four &#916K levels were selected to give crack growth rates typically ranging from 0.15 to 2.4 &#956m/cycle. Additionally, KIC fracture toughness tests were performed in both LT and TL directions, according to ASTM E1820. SEM fractographic analysis was conducted on constant &#916K fatigue specimens, in order to determine striation spacing created during the fatigue test. Macro- and microscopic crack growth rates were compared and good correlation have been obtained for data within the range from 0,1 to 1,0 &#956m/ciclo. Using the technique proposed by Berkovitz, loading history was estimated by the K-factor parametrization and the results were compared to the true loading spectrum imposed by the testing machine. Using the local striation spacing SL and for &#916K values lower than 23 MPam 1/2 (Paris region), the estimated loading exhibits an error less than 15%. Propagation life estimated by local striation spacing (microscopic crack growth rate) was compared to the true propagation life obtained from macroscopic crack growth rate values and the absolute difference between them was less than 15,7%. These results suggest that both life and loading history can be adequately estimated using the local SL striation spacing values.
84

Medidas da emissão de compostos carbonílicos por plantas / Measures of emission of carbonyl compounds by plants

Silvana Odete Pisani 04 July 2003 (has links)
A técnica de confinamento de folhas de plantas em câmara de Teflon rígido (cuvette), com visor em vidro, submetida a um fluxo contínuo de ar foi adotada na avaliação da emissão de compostos carbonílicos voláteis por plantas. Os carbonílicos foram coletados sobre sílica impregnada com o reagente derivatizante 2,4-dinitrofenilhidrazina e analisados por cromatografia a líquido de alto desempenho e detecção por ultravioleta. Foram identificados e quantificados aldeídos alifáticos saturados (C1 a C6) e insaturados (acroleína, metacroleína, crotonaldeído), benzaldeído, acetona e 2-butanona. A temperatura ambiente e na superfície das folhas, a umidade relativa do ar, a intensidade da luz solar e os níveis de ozônio e de óxidos de nitrogênio no ar foram monitorados durante as coletas de amostras. Com o objetivo de avaliar os níveis de fundo de carbonílicos no sistema coletor empregado, 29 amostras de ar foram coletadas sem a introdução de folhas de planta no cuvette, em condições ambientais de laboratório e campo. Uma avaliação estatística dos resultados indicou que os níveis de fundo do cuvette vazio foram próximos a zero nas coletas feitas no laboratório e aumentaram de acordo com o aumento da intensidade da luz solar nas coletas em campo. Esses resultados mostraram que a exposição do cuvette à radiação solar conduz à formação de artefato positivo de amostragem. Foram feitas medidas da emissão de carbonílicos pela espécie Ficus benjamina, para a qual foram observadas taxas de emissão de acetaldeído altas em condições de temperatura na superfície das folhas superior a 40°C. Na ausência de luz solar incidente, não foi observada emissão de carbonílicos pelo exemplar avaliado dessa espécie. Foram feitas também medidas da emissão de carbonílicos pelas seguintes espécies de plantas ocorrentes na vegetação nativa da Região Metropolitana de São Paulo: Cecropia pachystachya, Casearia sylvestris, Croton floribundus, Solanum erianthum, Alchornea sidifolia, Syagrus rommanzoffiana e Ficus insipida, para as quais foram observadas taxas de emissão de carbonílicos que variaram entre 1,5 10-2 e 2,3 µgC g-1 h-1. / The leaf enclosure technique in air flow-through rigid Teflon chamber (cuvette) was employed to evaluate volatile carbonyl compound emission from plants. The gaseous carbonyl compounds were collected on silica gel coated with 2,4-dinitrophenylhydrazine and analyzed by high performance liquid chromatography with ultra-violet detection. The identified and quantified carbonyls were saturated (C1 - C6) and unsaturated (acrolein, methacrolein, crotonaldehyde) aliphatic aldehydes, benzaldehyde, acetone and 2-butanone. Ambient and leaf surface temperatures, relative humidity, light intensity, ozone and nitrogen oxides air levels were monitored during carbonyl emission sampling. With the aim of evaluate the collection system carbonyl background leveIs, 29 air samples were collected from the empty cuvette under laboratory and field conditions. Statistical analysis of the data indicated that the cuvette background leveIs were close to zero under laboratory conditions and increased with the increasing of the sunlight intensity under field conditions. These results showed that the cuvette exposition to the sunlight leaded to positive sampling artifact. Carbonyl compound emission from Ficus benjamina species was measured and high acetaldehyde emission rates were observed under leaf surface temperature higher than 40°C. In the absence of direct sunlight no carbonyl emission was measured from the evaluated individual of Ficus benjamina. Also carbonyI emissions from the following native species in the metropolitan region of São Paulo City were measured: Cecropia pachystachya, Casearia sylvestris, Croton floribundus, Solanum erianthum, Alchornea sidifolia, Syagrus rommanzoffzana e Ficus insípida. The observed rate emissions from these plants ranged between 1,5 10 -2 and 2,3 µgC g-1 h-1.
85

Determinação da isotretinoína em medicamentos por cromatografia líquida de alta eficiência e caracterização por análise térmica e difração à laser / Determination of isotretinoin in pharmaceuticals products by high performance liquid chromatography and characterization by thermal analysis and laser diffraction

Carla Aiolfi Guimarães 06 December 2007 (has links)
A isotretinoína (ácido-13-cis-retinóico) é uma substância derivada da vitamina A. É indicada no tratamento de formas graves de acne nódulo císticas e resistentes a terapias anteriores. É uma substância termo e fotossensível, que requer cuidados especiais na formulação, produção e acondicionamento. Como atualmente existem várias preparações comerciais contendo essa substância, é importante que se estudem e validem métodos analíticos para sua determinação quantitativa, que possam ser aplicados no controle de qualidade destas formulações. O objetivo da pesquisa foi, portanto, a caracterização e a determinação quantitativa da isotretinoína, e avaliação do comportamento desta substância em três formulações farmacêuticas comercializadas no Brasil. Esta análise comparativa foi realizada através das técnicas de difração à laser, microscopia de luz polarizada, termogravimetria, e calorimetria exploratória diferencial, para caracterizar, respectivamente, a distribuição do tamanho de partícula e comportamento térmico. Não foi encontrada diferença entre o comportamento térmico das três amostras, mas na medida do tamanho de partícula, houve uma grande variação entre duas das três amostras. O tamanho de partícula é um fator conhecido que altera a absorção de moléculas no trato-gastrintestinal, podendo haver conseqüências na segurança e eficácia do produto. Foi desenvolvida e validada uma metodologia, para determinação quantitativa da isotretinoína nessas três amostras estudadas, um método de cromatografia líquida de alta eficiência, rápido e simples, empregando detector no UV. Duas das amostras ultrapassaram o limite de isotretinoína de 90 - 110% especificado pela Farmacopéia Americana. A apresentação, controle de qualidade e a caracterização de formulações farmacêuticas são importantes para assegurar a qualidade do produto final. Embora a cromatografia, análise térmica e determinação do tamanho de partícula sejam utilizadas pelas indústrias farmacêuticas, o tamanho de partícula ainda não é uma especificação definida pelas farmacopéias. Isso mostra a importância de futuras pesquisas, determinando o efeito dessas variações encontradas, possibilitando o estudo comparativo, entre a qualidade de produtos contendo isotretinoína em pacientes através de testes de bioequivalência. / Isotretinoin (13-cis retinoic acid), a vitamin A derivative is indicated for the treatment of several forms of acne, cystic nodules resistant to other therapies and also acts as an inhibitor of at proliferation neoplasic cells. It is a thermolabile substance, light and air sensitive and these physicochemical properties impose special cares in the formulation, development and packaging to avoid the isotretinoin degradation. Currently some preparations available on the stores contain this substance and it is important to study and validate quantitative methods to determine the quality control of these formulations. The purposes of research were to characterize, to determine quantitatively the isotretinoin and check the behavior of this substance in three pharmaceutical formulations available on the Brazilian stores. This comparative analysis was performed by laser diffraction/polarized light microscopy, thermogravimetry and differential scanning calorimetry techniques in order to characterize, respectively, the particle size distribution and the thermal behavior. The thermal stability was found to be none a variable parameter, the isotretinoin average particle size was significantly different in 2/3 formulations. Interestingly, the particle size is a facto r known to affect the absorption of the molecules from the gastrointestinal tract and, therefore, may have consequences for the safety and the efficiency of the product. Its was also developed and validated one analytical method for quantitative determination of isotretinoin in these three samples. A simple and rapid method using an isocratic high performance liquid chromatography and UV detection was developed. The average isotretinoin content of two ranged outside the 90 -110% date showed into United States Pharmacopeia specifications. Eventually, the design, the quality control and the characterization of the pharmaceutical formulations are important to ensure the quality of the final product. Although the chromatography, thermal and particle size analysis were currently used in the pharmaceutical industry, the particle size is not a specification stated in the pharmacopeias and should be considered with more interest. It would seem important; therefore, that future research determines the full effect of particle size variation and a comparative study with pharmaceutical quality of isotretinoin products on patient exposure to isotretinoin by comparative bioequivalence testes.
86

Desenvolvimento de metodologia analítica específica e seletiva para a determinação do nitrato de econazol em cremes / Development of a specific and selective analytical methodology for the determination of econazole nitrate in creams

Angel Arturo Gaona Galdos 18 April 2008 (has links)
Neste trabalho realizaram-se provas de identificação qualitativa e quantitativa do nitrato de econazol (matéria-prima); ensaios de caracterização térmica do nitrato de econazol, excipientes e formulação farmacêutica (creme), assim como desenvolvimento de metodologia analítica específica e seletiva para a quantificação do nitrato de econazol na formulação farmacêutica de creme. A caracterização térmica dos excipientes foi realizada usando-se a Termogravimetria (TG). Para a caracterização térmica do nitrato de econazol e da formulação foram empregadas a Termogravimetria, a Termogravimetria Derivada (TG/DTG) e a Calorimetria Exploratória Diferencial (DSC). Na caracterização térmica da formulação foram identificados e quantificados dois tipos de água com interações diferentes com a matriz. No desenvolvimento da metodologia específica utilizou-se a eletroforese capilar em zona, método linear com concentrações entre 80 e 120 µg mL-1, com coeficiente de correlação de 0,9995; precisão calculada como desvio padrão relativo (DPR) menor de 2%; exatidão do método comprovada mediante teste de recuperação, obtendo-se valores de 100±2,5%; limites de detecção e quantificação 1,853 µg.mL-1 e 5,617 µg.mL-1, respectivamente, comprovando-se também que o método é robusto. No desenvolvimento da metodologia seletiva foram usadas a cromatografia líquida de alta eficiência com eluição em gradiente (CLAE) e a eletroforese capilar pelo método da cromatografia eletrocinética micelar (MEKC). Nestes métodos foram separados o nitrato de econazol, as impurezas relatadas na literatura do nitrato de econazol (4-álcool clorobenzílico, alfa-2,4-diclorofenil-1 H¬imidazol-1-etanol) e os conservantes presentes na formulação (metilparabeno e propilparabeno). O método seletivo desenvolvido por CLAE foi linear para todas as moléculas, com coeficientes de correlação maiores de 0,99. A precisão calculada para o nitrato de econazol como DPR foi menor de 2%; a exatidão para o nitrato de econazol foi comprovada mediante teste de recuperação, obtendo-se valores de 100±2%; comprovou-se também que o método é robusto e que poderia ser aplicado para a quantificação de cada um destes cinco compostos. No método seletivo desenvolvido por MEKC se obteve tempo menor em comparação ao método por CLAE. / In this work, were performed qualitative and quantitative identitication econazole nitrate (raw material); thermal characterization of econazole nitrate, excipients and formulation (cream). There also were developed and validated specific and selective analytical methodology for quantitative determination of econazole nitrate in creams. The thermal characterization of drug product excipients was performed using the Thermogravimetry (TG). For the thermal characterization of econazole nitrate drug and their formulation were used the Thermogravimetry, Derivative Thermogravimetry (TG/DTG) and Differential Scanning Calorimetry (DSC). From cream formulation were identified and quantified two kinds of water which have different interactions with matrix. As regards lo developing of specific methodology was used the capillary zone electrophoresis (CZE). The method was linear, with a correlation coefficient of 0.9995 in the concentration range of 80 to 120 µg.mL-1 of econazole nitrate, precision calculated as relative standard deviation (RSD) was less than 2%, accuracy calculated percentage of recovery for commercial sample was of 100 ± 2.5%, detection and quantitation limits were 1.853 µg.mL-1 and 5.617 µg.mL-1, respectively. The CZE method showed to be robust. For developing of selective methodology were used high performance liquid chromatography (HPLC) with gradient elution, and micellar electrokinetic chromatography (MEKC) methods. Econazole nitrate, related impurities the drug (4-Chlorobenzyl alcohol, alpha-2,4-dichlorophenyl-1H - imidazole-1-ethanol) and preservatives (methylparaben, propylparaben) present in the drug product were separated. The HPLC method was linear for all analytes, the correlation coefficients were higher than 0.99. The precision for nitrate econazol in terms of RSD was less than 2%, the percentage of recovery for commercial sample of econazole nitrate was 100±2%, the method is robust and could be applied for the quantitation of the five substances cited above. With the MEKC method developed the five substances were separated less time comparated with HPLC method.
87

Estimativa da razão de carga a partir da análise fratográfica da relação entre a altura e espaçamento inter-estrias de uma liga de Alumínio aeronáutica AMS 7475-T7351 / Estimation of the load ratios by quantitative fractographic analysis of the ratio between height and the striation spacing of an aeronautical aluminium alloy AI AMS 7475-T7351

Aristides Alves Messias Filho 19 May 2006 (has links)
Este trabalho visa determinar a razão de carga cíclica R através da medida, na superficie de fratura, da relação entre a largura inter-estrias (s) e a altura da estria (H). É de conhecimento que o espaçamento (s) se correlaciona com a taxa de crescimento da trinca da/dN, enquanto que a curva da/dN x &#916K depende da razão de carga R. Para esta avaliação, corpos de prova do tipo compacto C(T) foram extraídos na orientação LT do centro de uma placa laminada da liga de alumínio SAE-AMS 7475 T7351 para realização dos ensaios de propagação de trinca por fadiga. Estes ensaios foram realizados de duas formas diferentes. A primeira, para obtenção de dados relativos à região II da curva da/dN x &#916K, sendo, neste caso, utilizadas quatro diferentes razões de carga (R=O,1; R=0,3; R=0,5; R=0,7). No outro caso, os ensaios de fadiga foram realizados sob &#916K constante e utilizados os mesmos quatro níveis de razão de carregamento R para determinação da curva da/dN x &#916K constante. Os níveis de &#916K aplicados foram tomados na região de Paris da curva da/dN x &#916K. A análise fratográfica por microscopia eletrônica foi conduzida nas superfícies dos corpos de prova do ensaio de fadiga com &#916K constante. Isto foi feito para determinar os espaçamentos inter-estria (s) e a altura H das estrias para cada nível de &#916K aplicado. Observou-se que a taxa de crescimento da trinca (da/dN) e o espaçamento inter-estrias (s) sofrem influência direta com a variação do fator de intensidade de tensão (&#916K), entretanto, observou-se, também, que a relação de proporcionalidade de 1:1 entre eles somente é válida para níveis de da/dN variando entre 0,1 a 1 &#956/ciclo. Os valores da morfologia da estrias (H/s) sofrem influência significativa com o aumento da razão de carga R, entretanto, ficou evidenciado que o fator de intensidade de tensão máxima Kmáx. não tem influência nesta relação. Evidenciou-se que a largura da estria corresponde à taxa de crescimento da trinca (da/dN), e que a relação entre a altura e o espaçamento da estria (H/s) possui uma correspondência direta com a razão de carga R, que tem influência significativa sobre a propagação de trinca por fadiga. / This work aims at to method to determine the load ratio R through of measure, on the fractured of surfaces the relation between the width striation spacing (s) and the height of the striation (H). It is of knowledge that the spacing (s), if correlates with the fatigue crack growth rates da/dN, whereas the curve da/dN x &#916K depends on the load ratio R. For this evaluation compact tension C(T) specimens had been extracted in the L- T orientation of a laminate plate of the aluminum alloy SAE-AMS 7475 T7351.These test had been carried out of two different forms. The first one, for attainment of relative data to region II of the curve da/dN x &#916K, being, in this in case that used four different load ratios (R=O,1; R=0,3; R=0,5; R=0,7). In the other in case that, the fatigue crack growth rates had been carried out under &#916K constant and used same the four levels of load ratios R for determination of the curve of constant da/dN x &#916K. The applied levels of &#916K had been taken in the region II of the curve da/dN x &#916K. The fractographic analysis for electronic microscopy was lead on the surfaces of the specimens tested in fatigue with constant &#916K. This was made to determine the striation spacing (s) and height (H) of the striations for each constant level of &#916K. It was observed that the fatigue crack growth rates (da/dN) and the striation spacing (s) suffers direct influence with the variation of &#916K. Also, was observed that the relation of proportionality of 1:1 between them is only valid for levels of da/dN in the range of 0,1 to 1,0 mm/cycle. The values of the relationship of the striation dimensions (H/s) suffer significant influence with the increasing of load ratios R. However, were evidenced that the value of Kmax. does not have influence in this relationship. It was found that the width of the striation corresponds to the value of (da/dN) and that the relation between the height and the striation of spacing (H/s) had a direct correspondence with the load ratios R that has signifficant effect on the fatigue crack growth rates.
88

A regionalização da saúde no Estado de Mato Grosso: o processo de implementação e a relação público-privada na região de saúde do Médio Norte Mato-grossense / The health\'s regionalization in the State of Mato Grosso: the process of implementation and the relationship public-private in the region\'s health of the Middle North\'s Mato Grosso

Nereide Lúcia Martinelli 07 October 2014 (has links)
A regionalização da saúde está contemplada no artigo 198 da Constituição Federal de 1988 e é uma diretriz do SUS, que prevê a articulação dos três entes federativos para a conformação do sistema de saúde e a efetivação do direito à saúde. Na implementação do SUS, a regionalização ganha destaque nos anos 2000, mas, no Estado de Mato Grosso, a partir de 1995, a reorientação político-institucional da Secretaria de Estado da Saúde definiu estratégias para a implementação do SUS por regiões de saúde e fortaleceu as instâncias públicas regionalizadas. A partir de 2003, houve trocas sucessivas do gestor estadual de saúde, com repercussão na maneira de conduzir a política estadual de saúde e, apesar da institucionalidade anteriormente construída, o processo de regionalização sofre certa estagnação. O presente estudo de caso analisa o processo de regionalização da saúde e o mix público-privado no sistema de saúde da região do Médio Norte do Estado, no período de 2006 a 2011. Tal recorte se justifica pela edição do Pacto pela Saúde 2006, que contempla a regionalização. Faz-se uso de análise qualitativa das entrevistas realizadas com informantes-chave e se utiliza de análise quantitativa de dados secundários. Com essas informações, pôde-se caracterizar os mecanismos e instrumentos adotados, bem como as relações público-privadas no sistema público de saúde; compreender como ocorre o processo decisório, a relação e a interação dos diversos atores que compõem o complexo regional desta região de saúde. Na região em estudo, na vigência do Pacto, a SES preservou e criou novos incentivos, manteve o Consórcio Intermunicipal de Saúde, implantou leitos de UTI, conservou o convênio com o hospital municipal de referência regional e sustentou os convênios com clínicas e laboratórios de apoio diagnóstico do setor privado. O CGR foi criado, mas sua governabilidade sobre a macropolítica da região é parcial e, embora seja um espaço de decisão colegiada, ainda tem características do somatório das partes e gera as mais diversas consequências na governança da política regionalizada. O PDR e o PDI não foram atualizados, a regulação da assistência que era desenvolvida pela região foi recentralizada, a SES atrasou o repasse dos incentivos financeiros aos fundos municipais de saúde e não investiu na construção do hospital regional. Apesar da trajetória do Estado na regionalização da saúde, a estrutura da rede pública de atenção à saúde não se expandiu e as parcerias estabelecidas com o setor privado fortaleceram sua participação na rede de atenção e têm influenciado o sistema regional de saúde. A região precisa da coordenação do estado na condução do processo de regionalização, sem a qual seu avanço fica comprometido / The Regional Health Planning is included at Art.198 of the Constitution of 1988 and it is a guideline the SUS that provides for the combination of the three federative for shaping the health system and the realization of the right to health. At the implementation of SUS, Regional Health Planning gained prominence in the 2000s, but in the state of Mato Grosso, since 1995 the reorientation political-institutional of the SES defined strategies to implementation of the SUS by regions the health and strengthened regionalized public instances. Since 2003 there were successive exchanges of state health manager, with repercussions on the manner to conduct the state health policy and, despite the earlier institutional, the Regional Health Planning process suffers certain stagnation. This case study analyzes the process of the Regional Health Planning and public-private mix in the health system of the Middle North region of the state, between the period from 2006 to 2011. The angle is justified by editing the health pact that include the Regional Health Planning. Makes use of a qualitative analysis from interviews with key informants and uses a quantitative analysis at secondary data. With this information it was possible to: characterize the mechanisms and instruments adopted, as well as relations public-private in the public health system; understand how occurs decision process; the relationship and interaction of various actors that compose this complex health. At the study region, at the presence of the health pact, the SES remained and created new incentives, kept the CIS, deployed UTI beds, kept the covenants with the municipal hospital of referral regional and with private clinical and laboratories of support diagnostic . The CGR was created, but the governance on the macro policy in the region is partial and although a space of collegial decision also has characteristics of the sum of the parts, and generates the most diverse consequences in the governance of regionalized policy. The PDR and PDI were not updated, the regulation of assistence developed by region was centralized, the SES delayed the transfer of financial incentives to municipal health funds and didn\'t invested in the construction of the regional hospital. Despite the state trajectory of the Regional Health Planning, the structure of public health care had not expanded and the partnerships with the private sector strengthened its participation in the care network and had influenciated the regional health system. The region needs the coordination of the state in the conduct of the regionalization process, without which its progress is compromised
89

Medidas da emissão de compostos carbonílicos por plantas / Measures of emission of carbonyl compounds by plants

Pisani, Silvana Odete 04 July 2003 (has links)
A técnica de confinamento de folhas de plantas em câmara de Teflon rígido (cuvette), com visor em vidro, submetida a um fluxo contínuo de ar foi adotada na avaliação da emissão de compostos carbonílicos voláteis por plantas. Os carbonílicos foram coletados sobre sílica impregnada com o reagente derivatizante 2,4-dinitrofenilhidrazina e analisados por cromatografia a líquido de alto desempenho e detecção por ultravioleta. Foram identificados e quantificados aldeídos alifáticos saturados (C1 a C6) e insaturados (acroleína, metacroleína, crotonaldeído), benzaldeído, acetona e 2-butanona. A temperatura ambiente e na superfície das folhas, a umidade relativa do ar, a intensidade da luz solar e os níveis de ozônio e de óxidos de nitrogênio no ar foram monitorados durante as coletas de amostras. Com o objetivo de avaliar os níveis de fundo de carbonílicos no sistema coletor empregado, 29 amostras de ar foram coletadas sem a introdução de folhas de planta no cuvette, em condições ambientais de laboratório e campo. Uma avaliação estatística dos resultados indicou que os níveis de fundo do cuvette vazio foram próximos a zero nas coletas feitas no laboratório e aumentaram de acordo com o aumento da intensidade da luz solar nas coletas em campo. Esses resultados mostraram que a exposição do cuvette à radiação solar conduz à formação de artefato positivo de amostragem. Foram feitas medidas da emissão de carbonílicos pela espécie Ficus benjamina, para a qual foram observadas taxas de emissão de acetaldeído altas em condições de temperatura na superfície das folhas superior a 40°C. Na ausência de luz solar incidente, não foi observada emissão de carbonílicos pelo exemplar avaliado dessa espécie. Foram feitas também medidas da emissão de carbonílicos pelas seguintes espécies de plantas ocorrentes na vegetação nativa da Região Metropolitana de São Paulo: Cecropia pachystachya, Casearia sylvestris, Croton floribundus, Solanum erianthum, Alchornea sidifolia, Syagrus rommanzoffiana e Ficus insipida, para as quais foram observadas taxas de emissão de carbonílicos que variaram entre 1,5 10-2 e 2,3 µgC g-1 h-1. / The leaf enclosure technique in air flow-through rigid Teflon chamber (cuvette) was employed to evaluate volatile carbonyl compound emission from plants. The gaseous carbonyl compounds were collected on silica gel coated with 2,4-dinitrophenylhydrazine and analyzed by high performance liquid chromatography with ultra-violet detection. The identified and quantified carbonyls were saturated (C1 - C6) and unsaturated (acrolein, methacrolein, crotonaldehyde) aliphatic aldehydes, benzaldehyde, acetone and 2-butanone. Ambient and leaf surface temperatures, relative humidity, light intensity, ozone and nitrogen oxides air levels were monitored during carbonyl emission sampling. With the aim of evaluate the collection system carbonyl background leveIs, 29 air samples were collected from the empty cuvette under laboratory and field conditions. Statistical analysis of the data indicated that the cuvette background leveIs were close to zero under laboratory conditions and increased with the increasing of the sunlight intensity under field conditions. These results showed that the cuvette exposition to the sunlight leaded to positive sampling artifact. Carbonyl compound emission from Ficus benjamina species was measured and high acetaldehyde emission rates were observed under leaf surface temperature higher than 40°C. In the absence of direct sunlight no carbonyl emission was measured from the evaluated individual of Ficus benjamina. Also carbonyI emissions from the following native species in the metropolitan region of São Paulo City were measured: Cecropia pachystachya, Casearia sylvestris, Croton floribundus, Solanum erianthum, Alchornea sidifolia, Syagrus rommanzoffzana e Ficus insípida. The observed rate emissions from these plants ranged between 1,5 10 -2 and 2,3 µgC g-1 h-1.

Page generated in 0.0928 seconds