• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 13
  • 10
  • Tagged with
  • 47
  • 30
  • 30
  • 24
  • 22
  • 20
  • 19
  • 18
  • 18
  • 15
  • 10
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Prédiction de l'intention à adhérer à la double thérapie antiplaquettaire suite à une angioplastie coronarienne

Doherty, Amélie January 2020 (has links) (PDF)
No description available.
22

Implantation d'une étude pilote d'intervention visant l'amélioration des fonctions cognitives chez des patients coronariens par la prise d'un supplément quotidien de vitamine K

Hogue, Crystèle 12 1900 (has links)
La vitamine K est reconnue pour son rôle dans la coagulation sanguine. Les apports alimentaires de cette vitamine influencent la stabilité de l’anticoagulothérapie à la warfarine sodique. Une intervention visant à augmenter de ≥ 150 μg/j les apports alimentaires de vitamine K a été développée au sein du laboratoire de Guylaine Ferland. Les données préliminaires d’un essai clinique randomisé contrôlé de 24 semaines ont montré que les participants ayant suivi la stratégie alimentaire portant sur la vitamine K ont présenté une anticoagulothérapie plus stable, comparativement aux participants du groupe témoin. Cette stratégie a été décrite afin de fournir les informations nécessaires à son application en pratique clinique. Les anticoagulants demeurent des piliers dans la prévention des évènements thrombotiques notamment chez certaines personnes atteintes de maladies cardiovasculaires (MCV). Parmi les MCV, les maladies du coeur [particulièrement la maladie coronarienne (MC)] sont les plus répandues. La MC peut accélérer le développement de troubles cognitifs avec l’âge, et ce déclin cognitif relève en grande partie de l’atteinte vasculaire sous-jacente. La vitamine K constitue un nutriment d’intérêt pour le système vasculaire et la cognition au cours du vieillissement et aurait le potentiel d'atténuer les effets néfastes de la MC sur le cerveau. Une étude pilote d’intervention de 12 semaines examinant l’impact d’un supplément de 500 μg/j de vitamine K sur les fonctions cognitives et vasculaires d’individus atteints de MC stable a été développée. Ce projet a été implanté à l’Institut de Cardiologie de Montréal en mai 2022, et à ce jour, quatre participants ont complété l’intervention. À terme, cette étude permettra d’obtenir une évaluation préliminaire des bénéfices associés à la supplémentation de vitamine K sur la cognition et à recueillir des preuves suffisantes justifiant la planification d’une étude de plus grande envergure au sein de cette population. / Vitamin K is known for its role in blood coagulation. Dietary intakes of this vitamin influence the stability of warfarin anticoagulation therapy. An intervention aiming to increase dietary vitamin K intakes by ≥ 150 μg/d was developed in Guylaine Ferland's laboratory. Preliminary data from a 24-week randomized controlled trial showed that participants who followed the vitamin K dietary strategy had more stable anticoagulation therapy compared to participants in the control group. This strategy was described to provide the necessary information for its application in clinical practice. Anticoagulants remain mainstays in the prevention of thrombotic events notably in certain people with cardiovascular disease (CVD). Among CVD, heart disease [particularly coronary heart disease (CHD)] is the most prevalent. Coronary heart disease can accelerate the development of cognitive impairment with age, and this cognitive decline is largely a consequence of the underlying vascular impairment. Vitamin K is a nutrient of interest for the vascular and nervous systems during aging, and has the potential to mitigate the adverse effects of CHD on the brain. A 12-week pilot study examining the impact of a 500 μg/d vitamin K supplement on cognitive and vascular functions in individuals with stable CHD was developed. This project was implemented at the Montreal Heart Institute in May 2022, and to date, four participants have completed the intervention. This study will provide a preliminary assessment of the benefits associated with vitamin K supplementation on cognition and provide sufficient evidence to justify the planning of a larger study in this population.
23

Développement d’un indice de vitalité dérivé à partir du Hexoskin afin d’obtenir une mesure d’angine digitale et raffiner l’étude de la maladie cardiaque athérosclérotique

Avram, Robert 12 1900 (has links)
Introduction: Jusqu’à la moitié des patients souffrant d’angine de poitrine vont continuer à être symptomatiques malgré une revascularisation coronarienne pour leur angine. Par ailleurs, l’évaluation de l’angine souffre du biais d’adaptation au seuil ischémique, phénomène par lequel les patients réduisent leur niveau d’activité physique pour limiter leurs symptômes. L’étude NOVA-SKIN (NCT02591758) utilise une veste intelligente (Hexoskin™) afin de (i) valider l’électrocardiogramme (ECG) de cette veste avec le Holter et l’épreuve d’effort (ii) dériver un “indice de vitalité” à partir des mesures biométriques de la veste, afin d’ajuster les mesures conventionnelles d’angine pour le biais d’adaptation au seuil ischémique et dériver des mesures d’angine digitale et (iii) évaluer si la réadaptation cardiaque à domicile peut être surveillée à distance avec le Hexoskin. Méthodes: Trente patients référés pour angiographie coronarienne pour leur angine réfractaire au traitement médical ont complété une épreuve d’effort et ont porté la veste Hexoskin (avec enregistrement simultané d’Holter) pendant 48 heures, 2 semaines avant leur examen. Les patients furent revus 2 semaines après la revascularisation coronarienne percutanée ou 6 semaines après la chirurgie cardiaque s’ils ont eu des pontages, où ils ont porté la veste Hexoskin avec Holter pendant 48 heures et fait une épreuve d’effort. Nous avons dérivé un indice de vitalité digital (Indice de vitalité = fréquence cardiaque * activité) chez chaque patient pour les deux enregistrements de la veste. Nous avons dérivé des mesures d’angine digitale en divisant ou multipliant (selon la direction de l’effet post coronarographie attendu) les mesures d’angine conventionnelle (classe SCC, pointage de qualité de vie, décompte de nitroglycérine et décompte d’angine) par l’indice de vitalité propre au patient. Nous avons comparé les différences (pré- et post-coronarographie) de mesures d’angine ajustées pour l’indice de vitalité dérivé à partir d’une veste intelligente (« angine digitale ») avec les mesures d’angine conventionnelles non ajustées. Les participants devaient ensuite compléter 6 sessions de réadaptation cardiaque à domicile sur une période de 1 mois. Une corrélation de Pearson fut obtenue entre la fréquence cardiaque de l’ECG de l’Hexoskin et celle du Holter et du tapis roulant. L’indice de vitalité pré et post-angiographie fut comparé en utilisant un test t et nous avons mesuré la taille de l’effet du traitement de l’angine dans le même patient, pour les mesures ajustées et non ajustées d’angine. Résultats: Trente patients, âgés de 68.0±7.0 ans, majoritairement des hommes (n=28; 93.3%) ont subi une angiographie coronarienne et ont été traités, pour leur angine, de façon percutanée (n=20; 66.7%), avec pontages (n=6; 20.0%) ou avec traitement médical (n= 4; 13.3%). Tous les patients étaient en rythme sinusal au départ. La fréquence cardiaque obtenue avec l’ECG de l’Hexoskin avait une corrélation très forte avec celle obtenue avec l’ECG du tapis roulant (r=0.95) et forte avec l’Holter (r=0.85). L’indice de vitalité a augmenté de manière significative (2.30±1.38 pré vs 2.70±1.12 post-traitement de l’angine; p=0.05). Les mesures d’angine digitale ayant montré une différence plus importante que les mesures conventionnelles sont le décompte hebdomadaire de nitroglycérine, l’échelle de santé globale du SF-36, la durée d’effort sur le tapis roulant et le nombre de METS maximal. Par ailleurs, chez les patients classifiés comme non-répondants au traitement de l’angine par mesures conventionnelles, les mesures d’angine digitale suivantes se sont améliorées de façon significative: classe SCC, décompte hebdomadaire d’angine, questionnaire d’angine de Seattle et la durée d’effort pendant l’épreuve d’effort. Aucun évènement cardiovasculaire ne s’est produit durant la réadaptation cardiaque à domicile et 93.3% des patients ont complété les 6 sessions. Conclusion : Dans notre étude pilote, l’ECG de Hexoskin a obtenu des mesures de fréquence cardiaque valides lorsque comparées au Holter et au tapis d’effort. L’incorporation d’un indice de vitalité obtenu à partir d’une veste intelligente a permis d’ajuster des mesures d’angine pour celui-ci et obtenir une angine digitale. La mesure d’angine digitale a une plus grande taille de l’effet post traitement de l’angine par revascularisation et peut détecter davantage de changements, au-delà des mesures d’angine conventionnelles. Cela est plus marqué chez les patients initialement classifiés comme “non-répondants” au traitement de l’angine. La réadaptation cardiaque à domicile fut sécuritaire et complétée par la majorité des patients. / Introduction : Up to half of coronary artery disease patients will remain symptomatic of angina, despite coronary revascularization. Moreover, the assessment of angina suffers from the ischemic threshold adaptation bias where patients will restrict their physical activity level in order to minimize their angina symptoms. The NOVA-SKIN study (NCT02591758) was designed to use a novel “smart clothing” (Hexoskin™) to (i) validate the electrocardiogram (ECG) signal of against traditional Holter and Treadmill stress tests (ii) to derive a ‘vitality index’ using the biometric measures obtained from the Hexoskin in order to adjust conventional angina assessment metrics to account for the ischemic threshold adaptation bias and derive a digital measure of angina and to (iii) assess if home cardiac rehabilitation can be remotely monitored using the Hexoskin system. Methods: Thirty stable angina patients referred for coronary angiography for refractory angina underwent a treadmill stress test and then simultaneously wore the Hexoskin vest and a traditional Holter monitor for 48 hours, 2 weeks before their exam. The patients were followed up 2 weeks after the percutaneous coronary intervention and 6 weeks after their cardiac surgery if they had coronary artery bypass graft. During the follow-up visit, they wore the vest with a Holter monitor for 48 hours and underwent another treadmill stress test. We obtained an average vitality index pre- and post-angiogram (Vitality index=heart rate * activity) using recordings from the vest. We also obtained health related questionnaires during the same timeframe. We compared differences in conventional angina metrics adjusted for the vitality index (“digital angina”) with the conventional metrics unadjusted for the vitality index, pre- and post-coronary angiography. Patients then had to complete 6 home cardiac rehabilitation sessions during a 1-month period. Pearson correlation was obtained between the heart rate (HR) derived from the ECG of the vest and the HR of the Holter and treadmill stress test. The vitality index pre and post-angiography was compared using a t-test. We derived digital angina metrics by dividing or multiplying (according to the direction of the effect expected post-coronarography) the conventional angina metrics. Then we measured the effect size of the angina treatment and compared it between adjusted and unadjusted metrics within the same patient. Results: Thirty patients aged 68.0±7.0 years (93.3% men; n=28) were enrolled in the study. Patients were treated with percutaneous coronary intervention (n=20; 66.7%), coronary artery bypass grafting (n=6; 20.0%) or medical therapy (n=4; 13.3%). The heart rate from ECG signal of the Hexoskin demonstrated a very strong correlation with that of the treadmill stress test ECG (r=0.95) and a strong correlation with the Holter (r=0.85). The vitality index increased significantly from 2.30±1.38 to 2.70±1.12 (p=0.05). The digital angina metrics (adjusted for the vitality index) that were found to be more responsive to the treatment of the angina than conventional were: the weekly nitroglycerin count, the global health sub-scale of the SF-36, the treadmill stress test length and the peak METs. Furthermore, in patients classified as non-responders to the treatment of angina by conventional metrics, the digital angina measures improved significantly, when looking at the CCS class, the weekly angina count, the Seattle Angina Questionnaire metrics and the duration of exercise on the treadmill stress test. No adverse events occurred during home cardiac rehabilitation and 28 patients completed all 6 sessions wearing the Hexoskin. Conclusion : In our pilot study, the Hexoskin ECG was well correlated with standard HR measurement using a treadmill ECG or a Holter. Adjusting conventional metrics for the vitality index allows for greater sensitivity in gauging the effect of revascularization on angina than conventional metrics alone, particularly for patients who would be considered non-responders to their treatment based on conventional metrics. Home cardiac rehabilitation was safe and was completed by most patients.
24

Bioresorbable coronary stents : non-invasive quantitative assessment of edge and intrastent plaque – a 256-slice computed tomography longitudinal study

Zdanovich, Evguenia 10 1900 (has links)
Les bioresorbable stents (BRS), en français intitulés tuteurs coronariens biorésorbables, sont constitués d’un polymère biorésorbable, plutôt que de métal, et ne créent pas d’artéfacts métalliques significatifs en tomodensitométrie (TDM). Cela permet une meilleure évaluation de la plaque coronarienne sous ces tuteurs en TDM qu’avec les anciens tuteurs qui sont en métal. OBJECTIF: Évaluer l’évolution de la composition de la plaque, sa fraction lipidique (FL)— marqueur de vulnérabilité de la plaque, dans les 3 zones pré-tuteur (bord proximal), intra-tuteur et post-tuteur (bord distal), et le volume de la plaque entre 1 et 12 mois post-implantation de BRS. MÉTHODOLOGIE: Il s’agit d’une étude observationnelle longitudinale réalisée chez 27 patients consécutifs (âge moyen 59,7 +/- 8,6 ans) et recrutés prospectivement pour une imagerie par TDM 256-coupes à 1 et 12 mois post-implantation de BRS (35 tuteurs total). Les objectifs primaires sont: volume de plaque totale et de FL (mm3) comparés entre 1 et 12 mois. Afin de tenir compte de la corrélation intra-patient, des analyses de variance des modèles linéaires mixtes avec ou sans spline sont utilisés avec deux facteurs répétés temps et zone/bloc (1 bloc= 5 mm en axe longitudinal). La valeur % FL= volume absolu du FL/ volume total de la plaque. RÉSULTATS: Notre analyse par bloc ou par spline n’a pas démontré une différence significative dans les volumes de plaque ou des FL dans les zones pre- intra- and post-tuteur entre 1 et 12 mois. CONCLUSION: Notre étude a réussi à démontrer la faisabilité d’une analyse non-invasive quantitative répétée de la plaque coronarienne et de la lumière intra-tuteur avec l’utilisation de TDM 256 coupes. Cette étude pilote n’a pas démontré de différence significative dans les volumes des plaques et atténuation entre 1- et 12- mois de follow-up post-implantation de BRS. Notre méthode pourrait être appliquée à l’évaluation des différents structures ou profils pharmacologiques de ces tuteurs. / Coronary bioresorbable stents (BRS) are made of a bioresorbable polymer rather than metal. Unlike metallic stents, BRS do not produce significant artifacts in computed tomography (CT) and are radiolucent in CT, making it possible to evaluate coronary plaque beneath an implanted stent. PURPOSE: The purpose of our study was to evaluate the volumes of plaque and low attenuation plaque components (LAP —a marker of plaque vulnerability) of pre-, intra- and post-stent plaque location between 1 and 12 months post-implantation. METHODS: In our prospective longitudinal study, we recruited 27 consecutive patients (mean age 59.7 +/- 8.6 years) with bioresorbable stents (n=35) for a 256-slice ECG-synchronized CT evaluation at 1 month and at 12 months post stent implantation. Total plaque volume (mm3) as well as absolute and relative (%) LAP volume per block in the pre-, intra- and post-stent zones were analyzed; comparison of 1 and 12 months post BRS implantation. Changes in these variables were assessed using mixed effects models with and without spline, which also accounted for correlation between repeated measurements with factors such as time and zone/block (1 block = 5 mm in longitudinal axis). The value % LAP= LAP absolute volume/ total plaque volume. RESULTS: Our block or spline model analysis showed no significant difference in plaque or LAP volumes in pre-, intra- and post-stent zones measured at 1 month and at 12 months. CONCLUSION: Our study demonstrates the feasibility of repeated non-invasive quantitative analysis of intrastent coronary plaque and in-stent lumen using a 256-channel CT scan. This pilot study did not show significant differences in plaque volume and attenuation between 1- and 12-month follow-up from stent implantation. The method we used could be applied to the evaluation of different stent structures or different pharmacological profiles of bioresorbable stents.
25

Endoprothèses vasculaires biorésorbables dans la revascularisation coronarienne : traitement de la coronaropathie extensive et caractéristiques angiographiques de la resténose

El Yamani, Mohammed El Mehdi 12 1900 (has links)
Il y a plus de 40 ans, la cardiologie interventionnelle a vu le jour et n’a cessé de révolutionner la prise en charge de l’athérosclérose coronarienne. Les endoprothèses vasculaires biorésorbables (BVS) avaient été conçues pour pallier les risques liés à la présence permanente de tuteurs métalliques dans les artères. En principe, ils fournissent de manière transitoire un soutien mécanique pour le scellement des dissections et la prévention du vasospasme et du remodelage constrictif en plus d’une élution médicamenteuse avant de se résorber et restaurer la vasomotricité coronarienne. L’enthousiasme autour des endoprothèses biorésorbables ABSORB™ était mitigé par un risque soutenu de thrombose du tuteur. Ce mémoire traitera en premier lieu des bases moléculaires de l’athérosclérose. Il abordera ensuite la prise en charge de la coronaropathie athérosclérotique ainsi que l’histoire de la cardiologie interventionnelle et ses différentes révolutions. Ensuite, deux études cliniques ont été conduites dans le cadre de ce travail et seront présentées. La première étude évalue le rôle du BVS dans la revascularisation de la coronaropathie extensive (multivaisseaux ou diffuse) et a montré que, dans un contexte aussi peu favorable au déploiement d’un tuteur coronarien, ABSORB™ a présenté des résultats cliniques acceptables à très long terme comparativement aux tuteurs métalliques de deuxième génération. La deuxième étude s’intéresse quant à elle aux caractéristiques angiographiques de resténose des BVS. Elle a démontré qu’à long terme, la resténose des BVS devient de plus en plus diffuse, et était associée à des issues cliniques moins favorables. Le dernier chapitre de ce mémoire se constitue d’une ouverture conclusive présentant les différentes endoprothèses biorésorbables actuellement à l’étude ou en cours de développement en soulignant leurs principales différences avec ABSORB™. / More than 40 years ago, interventional cardiology was born and has continued to revolutionize the management of coronary atherosclerosis. Bioresorbable Vascular Scaffolds (BVS) were designed to alleviate the risks associated with the permanent presence of metal stents in the arteries. In theory, they provide a transient mechanical support for sealing dissections and preventing vasospasm and constrictive remodeling in addition to a drug-eluting function before complete bioresorption and restoration of coronary vasomotion. Enthusiasm around the ABSORB™ bioresorbable scaffold was mitigated by a sustained risk of scaffold thrombosis. This thesis will first review the molecular basis of atherosclerosis. It will then discuss the management of atherosclerotic coronary artery disease, the history of interventional cardiology and its multiple revolutions. Then, two clinical studies that were conducted as part of this work will be presented. The first study that evaluates the role of BVS in the revascularization of extensive coronary artery disease (multivessel or diffuse) showed that, in such an unfavorable context for the deployment of a coronary stent, ABSORB™ has shown acceptable clinical results in the very long term compared to second generation drug-eluting stents. The second study focuses on the angiographic patterns of BVS restenosis. It showed that in the long term, the pattern of restenosis tended to be more diffuse than focal and that restenosis was associated with less favorable clinical outcomes. The final chapter of this thesis presents the different bioresorbable scaffolds currently under study or under development while highlighting their main differences with ABSORB™.
26

Étude de la réponse aiguë à l'exercice intermittent à haute intensité chez le patient coronarien

Guiraud, Thibaut 12 1900 (has links)
L'entraînement par intervalles à haute intensité est plus efficace que l'entraînement continu d’intensité modérée pour améliorer la consommation maximale d’oxygène (VO2max) et le profil métabolique des patients coronariens. Cependant, il n’y a pas de publications pour appuyer la prescription d’un type d’exercice intermittent (HIIE) spécifique dans cette population. Nous avons donc comparé les réponses aiguës cardio-pulmonaires de quatre sessions différentes d’exercice intermittent dans le but d’identifier l’exercice optimal chez les patients coronariens. De manière randomisée, les sujets participaient aux sessions d’HIIE, toutes avec des phases d’exercice à 100% de la puissance maximale aérobie (PMA), mais qui variaient selon la durée des phases d’exercice et de récupération (15s ou 1 min) et la nature de la récupération (0% de la PMA ou 50% de la PMA). Chaque session était réalisée sous forme de temps limite et l’exercice était interrompu après 35 minutes. En considérant l’effort perçu, le confort du patient et le temps passé au-dessus de 80% de VO2max, nous avons trouvé que l’exercice optimal consistait à alterner des courtes phases d’exercice de 15s à 100% de la PMA avec des phases de 15s de récupération passive. Ensuite, nous avons comparé les réponses physiologiques de l’HIIE optimisé avec un exercice continu d’intensité modérée (MICE) iso-calorique chez des patients coronariens. En considérant les réponses physiologiques, l’aspect sécuritaire (aucune élévation de Troponin T) et l’effort perçu, le protocole HIIE est apparu mieux toléré et plus efficace chez ces coronariens. Finalement, une simple session d’HIIE n’induit pas d’effets délétères sur la paroi vasculaire, comme démontré avec l’analyse des microparticules endothéliales. En conclusion, l’exercice intermittent à haute intensité est un mode d'entraînement prometteur pour les patients coronariens stables qui devrait faire l’objet d’autres études expérimentales en particulier pour les patients coronariens ischémiques. / High-intensity interval training has been shown to be more effective than moderate intensity continuous training for improving maximal oxygen uptake (VO2max) and metabolic profile in patients with coronary heart disease (CHD). However, no evidence supports the prescription of one specific protocol of high intensity interval exercise (HIIE) in this population. We have compared the acute cardiopulmonary responses to four different sessions of HIIE in order to identify the most optimal one in CHD patients. In random fashion, subjects performed the different HIIE sessions, all with exercise phases at 100% of maximal aerobic power (MAP), but which varied in interval duration (15 s or 60 s) and type of recovery (0% of MAP or 50% of MAP). Each protocol lasted 35 minutes or until exhaustion. When considering perceived exertion, patient comfort and time spent above 80% of VO2max, we found that repeated bouts of 15s at 100% of MAP interspersed by 15s phases of passive recovery was the optimal HIIE session for these coronary patients. Then, we compared the physiological responses to the optimized HIIE versus a moderate intensity continuous training (MICE) protocol of similar energy expenditure in coronary patients. When considering physiological responses, safety (no elevation of Troponin T) and perceived exertion, the HIIE protocol appeared to be well tolerated and more efficient in this group of stable coronary patients. Finally, a single bout of HIIE did not induce deleterious effects on the endothelium, as demonstrated by endothelial microparticules analyses. We conclude that high-intensity interval exercise is a promising mode of training for patients with stable CHD that should also be further investigated in cardiac patients, particularly with exercise-induced ischemia.
27

Les réponses physiologiques d'un entrainement intermittent de haute intensité chez les patients coronariens stables

Mekary, Saïd January 2008 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.
28

Réduction des artéfacts de tuteur coronarien au moyen d’un algorithme de reconstruction avec renforcement des bords : étude prospective transversale en tomodensitométrie 256 coupes

Chartrand-Lefebvre, Carl 08 1900 (has links)
Les artéfacts métalliques entraînent un épaississement artéfactuel de la paroi des tuteurs en tomodensitométrie (TDM) avec réduction apparente de leur lumière. Cette étude transversale prospective, devis mesures répétées et observateurs avec méthode en aveugle, chez 24 patients consécutifs/71 tuteurs coronariens a pour objectif de comparer l’épaisseur de paroi des tuteurs en TDM après reconstruction par un algorithme avec renforcement des bords et un algorithme standard. Une angiographie coronarienne par TDM 256 coupes a été réalisée, avec reconstruction par algorithmes avec renforcement des bords et standard. L’épaisseur de paroi des tuteurs était mesurée par méthodes orthogonale (diamètres) et circonférentielle (circonférences). La qualité d’image des tuteurs était évaluée par échelle ordinale, et les données analysées par modèles linéaire mixte et régression logistique des cotes proportionnelles. L’épaisseur de paroi des tuteurs était inférieure avec l’algorithme avec renforcement des bords comparé à l’algorithme standard, avec les méthodes orthogonale (0,97±0,02 vs 1,09±0,03 mm, respectivement; p<0,001) et circonférentielle (1,13±0,02 vs 1,21±0,02 mm, respectivement; p<0,001). Le premier causait moins de surestimation par rapport à l’épaisseur nominale comparé au second, avec méthodes orthogonale (0,89±0,19 vs 1,00±0,26 mm, respectivement; p<0,001) et circonférentielle (1,06±0,26 vs 1,13±0,31 mm, respectivement; p=0,005) et diminuait de 6 % la surestimation. Les scores de qualité étaient meilleurs avec l’algorithme avec renforcement des bords (OR 3,71; IC 95% 2,33–5,92; p<0,001). En conclusion, la reconstruction des images avec l’algorithme avec renforcement des bords génère des parois de tuteurs plus minces, moins de surestimation, et de meilleurs scores de qualité d’image que l’algorithme standard. / Metallic artifacts can result in an artificial thickening of the coronary stent wall which can significantly impair computed tomography (CT) imaging in patients with coronary stents. The purpose of this study is to assess the in vivo visualization of coronary stent wall and lumen with an edge-enhancing CT reconstruction kernel, as compared to a standard kernel. This is a prospective cross-sectional study of 24 consecutive patients with 71 coronary stents, using a repeated measure design and blinded observers, approved by the Local Institutional Review Board. 256-slice CT angiography was used, as well as standard and edge-enhancing reconstruction kernels. Stent wall thickness was measured with orthogonal and circumference methods, averaging wall thickness from stent diameter and circumference measurements, respectively. Stent image quality was assessed on an ordinal scale. Statistical analysis used linear and proportional odds models. Stent wall thickness was inferior using the edge-enhancing kernel compared to the standard kernel, either with the orthogonal (0.97±0.02 versus 1.09±0.03 mm, respectively; p<0.001) or circumference method (1.13±0.02 versus 1.21±0.02 mm, respectively; p<0.001). The edge-enhancing kernel generated less overestimation from nominal thickness compared to the standard kernel, both with orthogonal (0.89±0.19 versus 1.00±0.26 mm, respectively; p<0.001) and circumference (1.06±0.26 versus 1.13±0.31 mm, respectively; p=0.005) methods. The average decrease in stent wall thickness overestimation with an edge-enhancing kernel was 6%. Image quality scores were higher with the edge-enhancing kernel (odds ratio 3.71, 95% CI 2.33–5.92; p<0.001). In conclusion, the edge-enhancing CT reconstruction kernel generated thinner stent walls, less overestimation from nominal thickness, and better image quality scores than the standard kernel.
29

Évaluation qualitative d’une intervention infirmière d’entretien motivationnel à domicile auprès des personnes âgées sédentaires vivant avec la maladie coronarienne

Lavoie, Audrey 08 1900 (has links)
No description available.
30

L’augmentation de la circulation collatérale non coronarienne : l’hypothèse d’une méthode alternative de revascularisation myocardique / Enhancement of noncornary collateral circulation : the hypothesis of an alternative method of myocardial revascularization

Picichè, Marco 21 September 2011 (has links)
La circulation collatérale non coronarienne (CCNC) perfuse le cœur en provenant d’artères bronchiques, médiastinales et péricardiques. L’éventualité que la CCNC puisse être artificiellement augmentée pour fournir un traitement alternatif pour les patients ischémiques représente une hypothèse intrigante sans réponse en raison de la nature difficile de ce champ de recherche. En se basant sur plusieurs aspects, tel que (1) l’existence des collatérales naturelles entre les artères coronaires et les artères thoraciques internes (ATIs), (2) les effets potentiels de la ligature des ATIs; (3) la capacité des ATIs de développer d’importantes branches collatérales ; (4) et la disponibilité actuelle des facteurs de croissance vasculaire, l’hypothèse ici décrite est que l’augmentation de la CCNC pourrait représenter une stratégie alternative d’apport sanguin au coeur.Ainsi, l’association d’occlusion des ATIs et de l’administration des facteurs de croissance pourrait représenter un moyen de poursuivre cet objectif. Pour le premier travail de recherche, nous avons établi un modèle canin. / Noncoronary collateral circulation (NCCC) comes to the heart from mediastinal, bronchial, and pericardial channels. Whether NCCC can somehow be augmented to provide an alternative therapy for ischemic patients is an intriguing hypothesis with no clear answer yet due to the challenging nature of this research field. Based on several aspects, such as (1) the occurrence of natural collaterals between coronary and the internal thoracic arteries (ITAs), (2) the potentialhemodynamic effects of ITAs ligation, (3) the potential of ITAs for developing important collateral branches, and (4) the current availability of angiogenic growth factors, the hypothesis herein is that enhancement of NCCC may represent an alternative myocardial blood supply strategy, and that combining ITAs occlusion with angiogenic growth factors may represent a way to achieve this objective. We established an ischemic canine model for first experiment.

Page generated in 0.0602 seconds