• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 328
  • 1
  • Tagged with
  • 331
  • 105
  • 99
  • 80
  • 78
  • 68
  • 62
  • 61
  • 58
  • 57
  • 57
  • 52
  • 50
  • 46
  • 44
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Comparación in vitro de la formación de micro fisuras durante la retropreparación apical en premolares utilizando puntas diamantadas Woodpecker y Helse

Bernaola Medina, Gilberto Jeisson January 2019 (has links)
Ante el fracaso de un tratamiento y retratamiento endodóntico el protocolo adecuado que figura antes de llegar a una exodoncia es la cirugía apical. En la actualidad con una buena preparación científica, clínica y con la ayuda de la tecnología con los diversos equipos y puntas ultrasónicas en la especialidad de endodoncia; se pretende alcanzar una cirugía apical exitosa con una confección de una caja para obturación retrógrada óptima y con una mínima formación de micro fisuras destinarias a nivel del tercio apical de la raíz; para ello se utilizaron las puntas ultrasónicas diamantadas de retro preparación apical Woodpecker y Helse en el equipo ultrasónico Woodpecker UDSE; para determinar la formación de micro fisuras (MF); posterior a la retro preparación apical en premolares. El objetivo planteado de esta investigación fue evaluar la aparición de micro fisuras en la superficie apical posterior a la retro preparación; utilizando las puntas ultrasónicas diamantadas Woodpecker y Helse. La metodología que se empleó fue evaluativa – experimental in vitro; con una muestra no probabilística de treinta premolares, durante los meses de setiembre a octubre del 2017. La superficie radicular de las cavidades de la obturación retrógrada se analizaron visualmente con microscopía electrónica de barrido (SEM) y así poder detectar las micro fisuras dentinarias que se pudieron encontrar. Los resultados evidenciaron que hubo una mayor cantidad de micro fisuras por grupo después de la retro preparación apical y posterior al proceso de metalizado cuando se utilizó puntas diamantadas Helse y una menor cantidad de micro fisuras después de la retro preparación apical y posterior al proceso de metalizado cuando se utilizó puntas diamantadas Woodpecker.
322

Rugosidad superficial de agentes blanqueadores que contienen peróxido de hidrógeno. Estudio In vitro

Vigil Davila, Maria Vanessa January 2024 (has links)
El objetivo de esta investigación fue comparar in vitro los cambios en la rugosidad superficial de la estructura dentaria, generados por los diferentes agentes blanqueadores que contienen peróxido de hidrógeno (HP). El estudio consideró 50 especímenes obtenidos de dientes de bovino, seccionados en bloques dentales (7mm x 7mm x 7mm) y preparados para realizar una lectura inicial de rugosidad superficial (Ra), utilizando un perfilómetro. Las muestras fueron divididas aleatoriamente en 5 grupos (n= 10) según el agente blanqueador al que fueron expuestos: grupo1: Whiteness HP Maxx al 35%, grupo 2: Opalescence Boost 40% de HP, grupo 3: Opalescence Go 10% de HP, el grupo 4: Whiteness Perfect al 10% de peróxido de carbamida (CP) como control positivo y, el grupo 5: control negativo, con suero fisiológico. Al finalizar la etapa del blanqueamiento, las muestras se mantuvieron en suero fisiológico; finalmente, fueron sometidas al perfilómetro para determinar los parámetros de rugosidad superficial post blanqueamiento. Para el análisis estadístico se utilizó el paquete estadístico SPSS® 27.0. Para identificar si los datos siguen una distribución normal, se utilizó la prueba Shapiro Wilk (p > 0.05), luego se aplicó la prueba no paramétrica Prueba de Wilcoxon para muestras relacionadas (Inicial – final). Se concluyó que al aplicar los diferentes agentes blanqueadores que contienen peróxido de hidrogeno no se encontraron diferencias estadísticamente significativas entre los grupos; sin embargo, todos los grupos experimentales presentaron diferencias antes y después de la aplicación de los agentes blanqueadores. / The objective of this research was to compare in vitro the changes in the surface roughness of the tooth structure, generated by different bleaching agents containing hydrogen peroxide (HP). The study detected 50 specimens obtained from bovine teeth, sectioned into dental blocks (7 mm x 7 mm x 7 mm) and prepared to perform an initial reading of surface roughness (Ra), using a profilometer. The samples were randomly divided into 5 groups (n= 10) according to the whitening agent to which they were exposed: group 1: Whiteness HP Maxx 35%, group 2: Opalescent Boost 40% HP, group 3: Opalescent Go 10% HP, group 4: Whiteness Perfect with 10% carbamide peroxide (CP) as positive control and group 5: negative control, with physiological saline. At the end of the bleaching stage, the samples were kept in physiological saline solution; Finally, some profilometric measurements were performed to determine the postbleaching surface roughness parameters. The SPSS® 27.0 statistical package was used for statistical analysis. To identify whether the data follow a normal distribution, the Shapiro Wilk test was used (p > 0.05), then the non-parametric Wilcoxon test was applied for related samples (Initial – final). It is concluded that when applying the different whitening agents containing hydrogen peroxide, no statistically significant differences were found between the groups; however, all experimental groups presented differences before and after the application of the whitening agents.
323

Actividad inhibitoria de los aceites esenciales comerciales de Mentha spicata y Eucalyptus globulus sobre biopelículas de Streptococcus mutans en un modelo in vitro

Landeo Villanueva, Guillermo Ernesto January 2018 (has links)
Publicación a texto completo no autorizada por el autor / Evalúa la actividad inhibitoria de los aceites esenciales de Mentha spicata (hierba buena) y Eucalyptus globulus (eucalipto) de origen comercial sobre el desarrollo de biopelículas de Streptococcus mutans ATCC 25175 en un modelo in vitro, emulando las condiciones de la placa dental. La composición de los aceites esenciales (AE) se evaluó por Cromatografía de Gases acoplada a Espectrómetro de Masas (CG/EM) siendo los principales metabolitos el R-(–)-carvona (57,93%) y Llimoneno (12,907%) para Mentha spicata y el 1,8-cineol (eucaliptol) (65,83%) para Eucalyptus globulus. Se evaluó la actividad inhibitoria de los AE por los métodos de difusión en pozo de agar y microdilución colorimétrica. Los halos de inhibición fueron de 18,3 ± 0,47 mm y 27,0 ± 0,82 mm y los CMI de 1,8484 x 10-3 mg/mL y 1,9168 x 10-3 mg/mL, para los AE de Mentha spicata y Eucalyptus globulus respectivamente. La actividad frente a biopelículas se evaluó en un sustrato de piezas de esmalte dental bovino, empleando medio basal de mucina (BMM), en condiciones de anaerobiosis y ciclos diarios de exposición a la sacarosa, para emular las condiciones de la cavidad oral. Los AE se aplicarón a una concentración de 0,5% en un vehículo salino estéril con polisorbato 20 al 1%. Tras 72 horas de cultivo, se observó una reducción significativa (P <0,001%) en la biomasa de la biopelícula, evaluada por su turbidez en suspensión, y en el recuento de organismos recuperables respecto al control. Los efectos de ambos AE no resultaron significativamente distintos entre sí. Ambos AE presentan actividad antimicrobiana frente a S. mutans en cultivos planctónicos y de biopelícula, por lo que podría tener gran potencial para el desarrollo de productos farmacéuticos y sanitarios en el área de la salud oral. / Tesis
324

Comparación in vitro de la precisión dimensional de dos técnicas de impresión

Céspedes Brea, Bárbara Alisson 26 June 2017 (has links)
Objetivo: Comparar in vitro la precisión dimensional de la silicona por condensación mediante la técnica de impresión de doble mezcla; de doble impresión con alivio del margen y doble impresión con alivio total. Materiales y métodos: Las muestras estuvieron conformadas por 42 impresiones utilizando silicona por condensación Putty- Spedeex de un modelo maestro de acero inoxidable, el cual presentó dos pilares homogéneos que simularon la preparación para una corona. Estas muestras se dividieron en 3 grupos según la técnica de impresión (doble mezcla, doble impresión con alivio del margen y doble impresión con alivio total). Para determinar la precisión dimensional de los modelos definitivos en comparación al modelo maestro, se realizaron 7 mediciones (MD1, MD2, VL1, VL2, AL1, AL2, DI) con una máquina especializada en coordenadas, modelo Contura G2 con tecnología de Scanning por contacto ZEISS. Se realizaron las pruebas estadísticas Kruskal-Wallis y U de Mann-Whitney. Resultados: Se encontraron diferencias estadísticamente significativas (p˂0.001) en las medidas MD1, MD2, AL2 al comparar las 3 técnicas de impresión con el modelo maestro. La técnica de doble impresión con alivio total presentó una mayor cantidad de medidas (MD1, MD2, VL1, AL1, DI) que no mostraron diferencias estadísticamente significativas (p<0.005) en comparación al modelo maestro. Conclusiones: La técnica de doble impresión con alivio total presentó mayor precisión dimensional que las técnicas de doble mezcla y la técnica de doble impresión con alivio del margen utilizando silicona de condensación. / Objective: Compare in vitro the dimensional precision of the polivinil siloxano using the technique of impression of double mixture; double impression with margin relief and double impression with total relief. Materials and methods: The samples were composed of 42 impressions using Putty-Spedeex polivinil siloxano from a master stainless steel model, which presented two homogeneous pillars that simulated the preparation for a crown. These samples were divided into 3 groups according to the printing technique (double mix, double impression with margin relief and double impression with total relief). In order to determine the dimensional accuracy of the final models in comparison to the master model, 7 measurements (MD1, MD2, VL1, VL2, AL1, AL2, DI) were performed with a coordinated machine, Contura G2 model with contact scanning technology ZEISS. Statistical tests were performed Kruskal-Wallis and U of Mann-Whitney. Results: Statistically significant differences (p˂0.001) were found in measures MD1, MD2, AL2 when comparing the three printing techniques with the master model. The double impression technique with total relief presented a greater number of measures (MD1, MD2, VL1, AL1, DI) than did not show statistically significant differences (p <0.005) in comparison to the master model. Conclusions: The technique of double impression with total relief presented greater dimensional accuracy than the techniques of double mixing and the technique of double impression with relief of the margin using silicone of condensation.
325

Interacción de prótesis fija y prótesis parcial removible convencional en paciente edéntulo parcial

López Villacorta, Martha Yanett January 2016 (has links)
Detalla el proceso de rehabilitación oral de la paciente de género femenino de 57 años de edad, que acudió a la clínica de posgrado de odontología de la Universidad Nacional Mayor de San Marcos. La paciente presenta gingivitis leve, alteración del plano oclusal, disminución de la dimensión vertical oclusal y edentulismo parcial superior e inferior. Utiliza el tratamiento de rehabilitación oral con la colocación de prótesis parcial removible superior e inferior previa instalación de coronas individuales y recupera su dimensión vertical y las funciones del sistema estomatognático perdidas por el edentulismo parcial tales como la masticación, fonación y estética entre otras. / Tesis
326

Comparación in Vitro de la resistencia compresiva de las resinas tipo Bulk Filtek ™ Bulk Fill y Tetric® N-Ceram Bulk Fill vs las resinas tipo Core Allcem Core y Fusión DC Flo en la reconstrucción del núcleo dental. / In Vitro Comparison of the compressive strength of Bulk Filtek ™ Bulk Fill and Tetric® N-Ceram Bulk Fill resins vs Core Allcem Core and Fusion DC Flo resins in dental core reconstruction

Ojeda Nieto, Andrea del Rosario, Tapia Aldazabal, Nicole Shirley 07 September 2020 (has links)
Objetivo: Comparar in vitro la resistencia compresiva de 2 resinas tipo Bulk: Tetric® N-Ceram Bulk Fill y Filtek ™ Bulk Fill vs 2 resinas tipo Core: Allcem Core y Fusión Core DC Flo utilizadas en la reconstrucción del núcleo dental. Materiales y Métodos: La muestra estuvo conformada por 80 especímenes. La unidad de análisis fueron cilindros de resinas (4 mm x 4 mm). Se dividieron en 4 grupos (n=20); G1 Allcem Core, G2 Fusion Core DC Flo, G3 Filtek ™ Bulk Fill, G4 Tetric® N-Ceram Bulk Fill. La resistencia compresiva fue evaluada con la máquina Instron® (velocidad de desplazamiento fijo de 1.0mm/min). Los datos fueron analizados mediante la estadística descriptiva (media y desviación estándar). Se compararon las variables, resistencia compresiva y resinas (Bulk y Core), mediante la prueba de Wilcoxon, Kruskal Wallis y la prueba de Post Hoc (prueba Dunntest) (p< 0.05). Resultados: La media y desviación estándar obtenida para la resina Filtek ™ Bulk Fill fue de 236.98±47.89, Tetric® N-Ceram Bulk Fill fue de 224.94±45.06, Allcem Core fue de 318.73±26.57 y para fue de Fusion DC Flo fue de 208.41±42.03. Al comparar las resinas tipo Bulk, no se encontró diferencias significativas (p=0.387). Sin embargo, sí se halló diferencias entre las resinas tipo Core (p<0.001). Al comparar los 4 grupos de resinas se encontró diferencias significativas (p=0.001), a favor de Allcem Core. Conclusión: La resina Allcem Core presentó mayor resistencia a la compresión en comparación a Filtek ™ Bulk Fill, Tetric® N-Ceram Bulk Fill y Fusión Core DC Flo. / Objective: To compare in vitro the compressive strength of two Bulk resins: Tetric® N-Ceram Bulk Fill and Filtek ™ Bulk Fill vs two Core resins: Allcem Core and Fusion Core DC Flo used in dental core reconstruction. Materials and Methods: The sample was made up of 80 specimens. The units of analysis were resin cylinders (4 mm x 4 mm). They were divided into 4 ºgroups (n = 20); G1 Allcem Core, G2 Fusion Core DC Flo, G3 Filtek ™ Bulk Fill, G4 Tetric® N-Ceram Bulk Fill. Their compressive strength was evaluated with the Instron® universal machine (fixed displacement speed of 1.0mm / min). The data was analyzed using descriptive statistics (mean and standard deviation). Compressive strength and resins (Bulk and Core) were compared using the Wilcoxon test, Kruskal Wallis and the Post Hoc test (Dunntest) (p <0.05). Results: The mean and standard deviation obtained for Filtek ™ Bulk Fill resin was 236.98 ± 47.89, Tetric® N-Ceram Bulk Fill was 224.94 ± 45.06, Allcem Core was 318.73 ± 26.57 and for Fusion DC Flo it was 208.41 ± 42.03. No significant differences were found between Bulk Fill resins (p = 0.387). However, significant differences were found between Core resins (p <0.001). Finally, significant differences were found among the four groups of resins (p = 0.001) highlight Allcem core resin. Conclusion: Allcem Core resin showed higher compressive strength compared to Filtek ™ Bulk Fill, Tetric® N-Ceram Bulk Fill and Fusion Core DC Flo. / Tesis
327

Asociación entre el auto reporte de alergias debido al uso de materiales dentales con las características laborales de odontólogos de Lima Metropolitana, Perú / Association between the self-report of allergies due to the use of dental materials with the work characteristics of dentists in Metropolitan Lima, Perú

Muñoz Silva, Alejandra Giovana, Barreda Catacora, Víctor Daniel 07 July 2021 (has links)
Objetivo: Asociar el auto reporte de alergias debido al uso de materiales dentales con las características laborales de odontólogos de Lima Metropolitana, Perú. Materiales y métodos: Estudio observacional, analítico y transversal. La muestra estuvo constituida por 250 odontólogos. Se utilizó el cuestionario elaborado por Oviedo et al.1 para la evaluación de la presencia de alergias debido al uso de materiales dentales. Además, se incluyeron otras variables laborales como las horas de trabajo, especialidad y tiempo de ejercicio profesional. Se comprobó la validez interna del contenido, confiabilidad y fiabilidad del instrumento a partir de los estadísticos V de Aiken (0.9), Alpha de Cronbach (0.7) y Kappa de Cohen (1.0) respectivamente. Se obtuvieron frecuencias absolutas y relativas para el análisis univariado; y finalmente, se realizaron análisis de chi cuadrado, U de Mann Whitney para el análisis bivariado y la regresión de Poisson con estimador de varianza robusta para el análisis multivariado. Resultados: El 31.2% padecen de alergias y los materiales que causaron más alergias fueron el guante de látex (30.8%), represa de goma de látex (24.4%) y el acrílico (8%). En el análisis crudo se encontró una asociación entre la alergia con el sexo y la especialidad, encontrándose un RP de 1.65 (IC 95% = 1.14 a 2.39) y un RP de 1.90 (IC 95% = 1.32 a 2.72) respectivamente. Conclusión: La hipersensibilidad más común fue al látex y acrílico. El sexo y la especialidad fueron relacionadas a la presencia de alergias, es decir existe una asociación significativa entre la presencia de alergia relacionado al sexo y especialidad del participante. / Objective: Associate the self-report of allergies due to the use of dental materials with the work characteristics of dentists in Metropolitan Lima, Peru. Materials and methods: Observational, analytical and cross-sectional study. The sample consisted of 250 dentists. The questionnaire developed by Oviedo et al. 1 for the evaluation of the presence of allergies due to the use of dental materials. In addition, other labor variables such as hours of work, specialty and time of professional practice were included. The internal validity of the content, reliability and reliability of the instrument was verified from the Aiken's V statistics (0.9), Cronbach's Alpha (0.7) and Cohen's Kappa (1.0) respectively. Absolute and relative frequencies were obtained for the univariate analysis; and finally, chi square analysis, Mann Whitney U for bivariate analysis and Poisson regression with robust variance estimator for multivariate analysis were performed. Results: 31.2% suffer from allergies and the materials that caused the most allergies were latex glove (30.8%), latex rubber dam (24.4%) and acrylic (8%). In the crude analysis, an association was found between allergy with sex and specialty, finding a PR of 1.65 (95% CI = 1.14 to 2.39) and a PR of 1.90 (95% CI = 1.32 to 2.72) respectively. Conclusion: The most common hypersensitivity was to latex and acrylic. Sex and specialty were related to the presence of allergies, that is, there is a significant association between the presence of allergy related to the sex and specialty of the participant. / Tesis
328

Uso de diferentes materiales restauradores en rehabilitación adhesiva de un paciente con desgaste moderado: Reporte de caso

Masias Percca, Rocio del Carmen 07 January 2022 (has links)
El desgaste dentario patológico es el atípico para la edad del paciente, provocando dolor o malestar, problemas funcionales o deterioro del aspecto estético que, de progresar, puede dar lugar a complicaciones indeseables de complejidad creciente. El objetivo de este artículo es presentar un caso clínico de una rehabilitación oral, restaurando las estructuras dentarias desgastadas y restauraciones perdidas mediante el uso de diferentes materiales adhesivos. Se propuso rehabilitación con prótesis fija arcada inferior y superior que se realizó en tres fases: Restauraciones directas de resina en sector anteroinferior y carillas palatinas de resina indirectas anterosuperior; provisionalización de sectores postero inferior y posterosuperior; preparación y cementación de restauraciones indirecta. Para finalizar la confección de férula miorelajante junto a instrucción de guía de hábitos alimenticios. / Pathological tooth wear is atypical for the age of the patient, causing pain or discomfort, functional problems or deterioration of the aesthetic appearance that, if it progresses, can lead to undesirable complications of increasing complexity. The objective of this article is to present a clinical case of an oral rehabilitation, restoring worn tooth structures and lost restorations through the use of different adhesive materials. Rehabilitation with a fixed lower and upper arch prosthesis was proposed, which was performed in three phases: direct resin restorations in the anteroinferior sector and indirect anterosuperior resin palatal veneers; provisionalization of the posterior inferior and posterior superior sectors; preparation and cementation of indirect restorations. All in all, the preparation of myorelaxing splint together with instruction on the guide on eating habits. / Trabajo académico
329

Comparación in vitro de la rugosidad superficial de resinas Bulk Fill sometidos a diferentes sistemas de pulidos / In Vitro comparison of the surface roughness of Bulk Fill resins using different polishing systems

Flores Angulo, Maricielo, Julca Chávez, Stefany Christel 07 September 2020 (has links)
Objetivo: Comparar in vitro la rugosidad superficial de resinas Bulk Fill sometidos a diferentes sistemas de pulido. Materiales y métodos: Noventa especímenes de resinas compuestas: Tetric® N-Ceram Bulk Fill (TNC), Filtek™ Bulk Fill (FB) y Opus Bulk Fill (OBF) fueron divididos en 9 grupos (n=10). Cada grupo fue sometido a un sistema de pulido: Cauchos Politip (CP), Discos Sof-lex™ (DS) y Discos Diamond Pro (DDP). La rugosidad superficial inicial y final fue evaluada mediante un rugosímetro. Los datos fueron analizados mediante estadística descriptiva (media ± d.e) y para la comparación de diferencias de rugosidad inicial y final se utilizó la prueba de Kruskal Wallis (p<0.05). Resultados: La rugosidad superficial inicial (media + d.e, CP/DS/DDP) fue: TNC (1.23± 1.30µm/0.94±0.53µm/0.90±0.57µm); FB (0.53±1.29µm/0.59±0.54µm/0.63±0.26µm) y OBF (0.74±0.50µm/0.96±0.62µm/0.65±0.25µm). La rugosidad final fue: TNC (0.19± 0.04µm/0.32±0.23µm/0.28±0.22µm); FB (0.29±0.17µm/0.22±0.19µm/0.25±0.19µm) y OBF (0.15±0.05µm/0.26±0.24µm/0.20±0.14µm). No se encontraron diferencias estadísticamente significativas entre la rugosidad inicial y la rugosidad final TNC (p=0.479); FB (p=0.163) y OBF (p=0.919). Conclusión: Existe una disminución en los valores de rugosidad superficial de las resinas Bulk Fill evaluadas después de ser sometidas a tres sistemas de pulidos. / Aim: To compare in vitro the surface roughness of Bulk Fill resins using different polishing systems. Materials and methods: Ninety specimens: Tetric® N-Ceram Bulk Fill (TNC), Filtek™ Bulk Fill (FB) and Opus Bulk Fill (OBF) were divided into 9 groups (n=10). Each group was polished using a different polishing system: Politip Polishers (PP), Sof-lex Polishing Discs™ (SPD) and Diamond Pro Sandpaper Disk (DPSD). The initial and final roughness were assessed using a profilometer. The results were analyzed using descriptive statistics (mean ±s.d) and for the comparison of differences in initial and final roughness was analyzed using the Kruskal Wallis test (p<0.05). Results: The initial surface roughness (mean ± s.d, PP/SPD/DPSD) was: TNC (1.23 ±1.30um/0.94±0.53um/0.90±0.57um); FB (0.53±1.29um/0.59±0.54um/0.63±0.26um) and OBF (0.74±0.50um/0.96±0.62um/0.65±0.25um). The final surface roughness was: TNC (0.19±0.04um/0.32±0.23um/0.28±0.22um); FB (0.29±0.17um/0.22±0.19um/0.25±0.19um) and OBF (0.15±0.05um/0.26±0.24um/0.20±0.14um). There were no significant differences between the initial and the final roughness measurements: TNC (p=0.479); FB (p=0.163) and OBF (p=0.919). Conclusion: There is a minor decrease in the surface roughness measurements of the Bulk Fill resins after using three different polishing systems. / Tesis
330

Evaluación biológica de nuevos recubrimientos osteoinductores sintetizados vía sol-gel para aplicación en implantología dental

Lara Sáez, Irene 10 June 2015 (has links)
[EN] ABSTRACT In this Doctoral Thesis, the author carried out the biological evaluation of new silicon-based hybrid (organic-inorganic) coatings, synthesized by sol-gel route, used as osseointegrator and osteoinductor coatings applied to titanium radicular prosthesis in the dental implantology field. The biological evaluation of the new coatings consisted of a complete study to determine the effect of the coatings in the osteoblastic cell line and the tissular effects after the in vivo implantation in rabbit tibia (foreign-body reaction response and osseointegration), by histological study. The biological characterization was complemented with a physicochemical characterization of the materials, determining their topography, wettability, surface reactivity, as well as their degradation rate and silicon delivery, to explain the biological behaviour that each material induced. The coatings that showed a better cell behaviour were selected as material candidates for the in vivo implantation phase. This part of the work consisted of two experimental phases: (1) Characterization Phase I, from which one formulation prototype was obtained, and (2) Characterization Phase II, where different chemical improvements of the prototype were evaluated and a final coating prototype was selected. The degradable coatings that were obtained released silicon compounds during their hydrolytic degradation, inducing the implant osseointegration by distance osteogenesis. The new coatings offer the possibility to functionalize the titanium surface and serve like delivery vehicle of biomolecules and drugs that could improve and accelerate the titanium osseointegration process. / [ES] RESUMEN En esta Tesis Doctoral se llevó a cabo la evaluación biológica de nuevos recubrimientos híbridos (orgánico-inorgánico), sintetizados vía sol-gel, basados en precursores de silicio, como recubrimientos osteointegradores y osteoinductores aplicados a prótesis radiculares de titanio en el ámbito de la implantología dental. La evaluación biológica de los nuevos recubrimientos constó de un estudio completo para determinar el efecto de los recubrimientos sobre cultivos celulares de linaje osteoblástico y el efecto de los tejidos tras la implantación in vivo en tibia de conejo (respuesta de reacción a cuerpo extraño y osteointegración), mediante estudio histológico. La caracterización biológica se complementó con una caracterización físico-química de los materiales, determinando su topografía, su mojabilidad, la reactividad de su superficie, así como su grado de degradación y la liberación de silicio, para explicar el comportamiento biológico que cada uno de los materiales indujo. Los recubrimientos que presentaron un mejor comportamiento celular fueron seleccionados como materiales candidatos para llevar a la fase de implantación in vivo. Este trabajo constó de dos fases experimentales; (1) la Fase de Caracterización I de la que se extrajo una formulación prototipo, sobre la cual se realizaron mejoras químicas evaluadas en la (2) Fase de Caracterización II, de la cual fue elegido el recubrimiento prototipo final. Se obtuvieron recubrimientos degradables en cuya degradación hidrolítica liberaron compuestos de silicio que indujeron la osteointegración de los implantes recubiertos mediante osteogénesis a distancia, sin interferir en el proceso de osteointegración del titanio. Los nuevos recubrimientos ofrecen la posibilidad de funcionalizar la superficie del titanio y servir de vehículo de liberación de biomoléculas y fármacos que puedan mejorar y acelerar el proceso de osteointegración del titanio. / [CA] RESUM En aquesta Tesi Doctoral es va dur a terme l'avaluació biològica de nous recobriments híbrids (orgànic-inorgànic), sintetitzats via sol-gel, basats en precursors de silici, com recobriments osteointegradors i osteoinductors aplicats a pròtesis radiculars de titani en l'àmbit de la implantologia dental. L'avaluació biològica dels nous recobriments va constar d'un estudi complet per determinar l'efecte dels recobriments sobre cultius cel¿lulars de llinatge osteoblástic i l'efecte dels teixits després de la implantació in vivo en tèbia de conill (resposta de reacció a cos estrany i osteointegració), mitjançant estudi histològic. La caracterització biològica es va complementar amb una caracterització fisicoquímica dels materials, determinant la seva topografia, la seva mullabilitat, la reactivitat de la seva superfície, així com el seu grau de degradació i l'alliberament de silici, per explicar el comportament biològic que cada un dels materials va induir. Els recobriments que van presentar un millor comportament cel¿lular van ser seleccionats com materials candidats per portar a la fase d'implantació in vivo. Aquest treball va constar de dues fases experimentals; (1) la Fase de Caracterització I de la qual es va extreure una formulació prototip, sobre la qual es van realitzar millores químiques avaluades en la (2) Fase de Caracterització II, de la qual va ser elegit el recobriment prototip final. Es van obtenir recobriments degradables, en la seva degradació hidrolítica van alliberar compostos de silici que van induir l'osteointegració dels implants recoberts mitjançant osteogènesi a distància. Els nous recobriments ofereixen la possibilitat de funcionalitzar la superfície del titani i servir de vehicle d'alliberament de biomolècules i fàrmacs per poder millorar i accelerar el procés d'osteointegració del titani. / Lara Sáez, I. (2015). Evaluación biológica de nuevos recubrimientos osteoinductores sintetizados vía sol-gel para aplicación en implantología dental [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/51463

Page generated in 0.0811 seconds