531 |
Desenvolvimento de um sistema terap?utico emulsionado para uso oral a base de ?leo de r?-touro (Rana catesbeiana Shaw)Moro, Renata Rutckeviski 22 June 2015 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2018-01-15T22:12:26Z
No. of bitstreams: 1
RenataRutckeviskiMoro_DISSERT.pdf: 2237359 bytes, checksum: 38ee9b608bb33566f80348e060646864 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-01-18T14:11:18Z (GMT) No. of bitstreams: 1
RenataRutckeviskiMoro_DISSERT.pdf: 2237359 bytes, checksum: 38ee9b608bb33566f80348e060646864 (MD5) / Made available in DSpace on 2018-01-18T14:11:18Z (GMT). No. of bitstreams: 1
RenataRutckeviskiMoro_DISSERT.pdf: 2237359 bytes, checksum: 38ee9b608bb33566f80348e060646864 (MD5)
Previous issue date: 2015-06-22 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / Fontes alternativas de ?leos naturais est?o sendo constantemente avaliadas
para atender a demanda por mat?rias-primas naturais para o desenvolvimento de
novos produtos. O objetivo deste trabalho foi estudar a estabilidade oxidativa e
t?rmica do ?leo de r?-touro (Rana catesbeiana Shaw), assim como desenvolver uma
emuls?o baseado em um planejamento experimental com aplica??o para via oral. O
tecido adiposo da Rana catesbeiana Shaw foi utilizado como fonte para a produ??o
de um ?leo natural a partir do m?todo de extra??o a quente, obtendo rendimento de
60 ? 0,9%. O ?leo de r?-touro foi fisicoquimicamente caracterizado e os ?ndices de
per?xido, acidez, iodo e saponifica??o foram respectivamente 1,9 meq O2 / kg; 2,9
KOH / g de ?leo; 104,2 g de I / 100 g de ?leo e 171,2 mg de KOH / g de ?leo. A
cromatografia gasosa acoplada a espectrometria de massas foi usada para a
determina??o dos compostos presentes no ?leo de r?-touro, apresentando como
principais constituintes o ?cido ol?ico (30 %) e o ?cido eicosapentaen?ico (17,6%),
que s?o ?cidos graxos insaturados e poliinsaturados, respectivamente. A
estabilidade oxidativa foi determinada na presen?a e aus?ncia dos antioxidantes
butilhidroxianisol (BHA) e butilhidroxitolueno (BHT), a 60 ? 2 ?C durante 15 dias e a
temperatura ambiente durante 120 dias. Foram avaliados os ?ndices de acidez,
per?xido, iodo e saponifica??o; dienos e trienos conjugados, tempo de indu??o a
oxida??o (Rancimat?) e mudan?as nos espectros de infravermelho. A taxa de
oxida??o do ?leo de r?-touro foi dependente da temperatura e o ?leo apresentou-se
mais estavel na presen?a de BHT. Durante a oxida??o do ?leo, mudan?as
significativas no espectro de absor??o do ultravioleta vis?vel e infravermelho foram
observadas. O ?leo apresentou-se est?vel at? 200?C atrav?s da determina??o da
estabilidade t?rmica utilizando a calorimetria explorat?ria diferencial e an?lise
termogravim?trica. Um produto farmac?utico emulsionado para uso oral a base do
?leo de r?-touro utilizando o planejamento fatorial completo 23 foi desenvolvido,
caracterizado e sua estabilidade contendo diferentes adjuvantes farmac?uticos foi
avaliada. A emuls?o oral apresentou tamanho de got?cula de 410 ? 8,3 nm, potencial
zeta - 38,2 mV, condutividade 1913.8 ?S/cma e pH 6.4. O uso de adjuvantes foi
respons?vel por melhorar a estabilidade termooxidativa do ?leo disperso na emuls?o
por um per?odo superior a tr?s meses. Portanto, a formula??o desenvolvida exibiu
caracter?sticas tecnol?gicas promissoras para estabilidade termooxidativa da
emuls?o contendo o ?leo de r?-touro para uso oral. / Alternative sources of natural oils are constantly being investigated to meet
the demand for natural raw materials used for the development of new products. The
aim of this work was to study the oxidative and thermal stability of the bullfrog oil
(Rana catesbeiana Shaw), as well as to develop an emulsion based on an
experimental design with application to the oral route. The adipose tissue of Rana
catesbeiana Shaw was used as a source for producing natural oil by a hot extraction
method, with yield of 60 ? 0.9%. The bullfrog oil was characterized and peroxide,
acidity, iodine and saponification values were respectively 1.92 meq O2 / kg; 2.95
KOH / g oil; 104.2 g of I / 100 g oil and 171.2 mg KOH / g of oil. The gas
chromatography-mass spectrometry (GC / MS) was used to determine the
compounds present in the bullfrog oil. The main constituents are oleic acid (30%) and
eicosapentaenoic acid (17.6%), which are monounsaturated and polyunsaturated
fatty acids respectively. Oxidative stability was determined in the presence or
absence of the antioxidants BHA (butylhydroxyanisole) and BHT
(butylhydroxytoluene) at 60 ? 2 ? C for 15 days and at room temperature for 120
days. Values of acidity, peroxide, iodine and saponification; conjugated dienes and
trienes, oxidation induction time (Rancimat?) and changes in the infrared spectra
were measured. The bullfrog oil oxidation rate was dependent on temperature, and
the oil became more stable in the presence of BHT. During the oil oxidation,
significant changes in the ultraviolet visible absorption spectrum and infrared were
observed. Differential scanning calorimetry (DSC) and thermogravimetric analysis
(TGA) showed that the oil was stable up to 200 ?C.
|
532 |
Controle de sistemas com atrasos no tempo na presença de atuadores saturantesGhiggi, Ilca Maria Ferrari January 2008 (has links)
Neste trabalho, aborda-se o problema de estabilização de sistemas lineares com atrasos nos estados e sujeitos a ação de atuadores saturantes. Em particular, são propostos métodos para a síntese de leis de controle estabilizantes do tipo realimentação de estados, realimentação dinâmica de saída, bem como para a síntese de compensadores de "anti-windup" estáticos e dinâmicos. Como objetivo de síntese consideram-se duas possibilidades, que o sistema esteja livre ou não de perturbações. No primeiro caso, determina-se uma lei de controle estabilizante de tal forma a maximizar um conjunto de condições iniciais admissíveis D. No caso do conjunto D ser dado, a lei de controle estabilizante que se determina, deve garantir estabilidade assintótica do sistema em malha-fechada para toda condição inicial pertencente a D. No segundo caso, considerando-se os problemas de atenuação e tolerância à perturbação, as leis de controle são obtidas com o intuito de minimizar o ganho-L2 entre a perturbação e a saída regulada do sistema ou de maximizar o limite superior da norma L2 das perturbações admissíveis, para as quais garante-se que as trajetórias do sistema em malha-fechada permaneçam limitadas. Condições locais e globais de estabilização são obtidas a partir da teoria de Lyapunov e da modelagem por zona-morta da saturação, com a conseqüente aplicação de uma condição de setor generalizada. Em se tratando de sistemas contínuos, para que as condições obtidas sejam dependentes do atraso, combinam-se estas ferramentas com a representação do sistema através de sistema descritor. Já no caso de sistemas discretos, combinam-se estas duas ferramentas com a utilização do Lema de Finsler. A utilização destas ferramentas possibilita que as condições obtidas sejam na forma de desigualdades matriciais lineares (LMI's) ou quase lineares, permitindo assim, a formulação de problemas de otimização convexos. / In this work, we deal with the problem of stabilization of linear systems with delayed state and saturating inputs. Specifically, methods are proposed for the synthesis of stabilizing control laws of state feedback and dynamic output feedback types, as well as for the synthesis of static and dynamic anti-windup compensators. Regarding synthesis objectives two possibilities were considered, that the system is free or not of disturbances. In the first case, the stabilizing control law is computed considering the maximization of the set of admissible initial conditions D. In the case the set D is given, this stabilizing control law should guarantee asymptotic stability of the closed-loop system. In the second case, considering the problems of tolerance and disturbance attenuation, the control laws are proposed in order to minimize the L2 gain between to disturbance and the regulated output of system, or in order to maximize the bound on the admissible disturbances for which the trajectories are bounded. Local and global conditions for stabilization are obtained from the theory of Lyapunov and the modeling of the saturation by means of deadzone nonlinearities and the consequent application of a modified sector condition. For continuous systems, in order to obtain delay dependent conditions, these tools are combined with descriptor approach. In the case of discrete-time systems, these two tools are combined with the utilization of Finsler's Lemma. The use of these leads to the conditions in the form of Linear Matrix Inequalities (LMI's) or almost linear, allowing the formulation of convex optimization problems.
|
533 |
Estudo da estabilidade, caracterização e validade do Efavirenz: viabilização como padrão secundário / Stability study, characterization and validity of Efavirenz: viability as a secondary standardSouza, Karina Rocha de January 2015 (has links)
Made available in DSpace on 2016-04-04T12:25:59Z (GMT). No. of bitstreams: 2
12.pdf: 4572506 bytes, checksum: 7e5fdf7b0ca0370249e1dda4df35b8bb (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2015 / Fundação Oswaldo Cruz. Instituto de Tecnologia em Fármacos/Farmanguinhos. Rio de Janeiro, RJ, Brasil. / A infecção pelo vírus da imunodeficiência humana (HIV), comumente conhecida como AIDS, constitui-se em uma das mais sérias doenças infecciosas, sendo um grande desafio para a saúde pública. Apesar de não existir nenhum tratamento para erradicar a infecção, o uso de antirretrovirais é a melhor opção para a supressão viral. O efavirenz é um inibidor não nucleosídico da transcriptase reversa e o terceiro mais utilizado no tratamento antirretroviral, devido às suas propriedades farmacológicas e alta potência in vivo. De acordo com a Agência Nacional de Vigilância Sanitária (ANVISA), padrões de referência oficiais devem ser usados sempre que existirem, e na sua ausência padrões de referência devidamente caracterizados (padrões secundários) deverão ser utilizados. Não existe uma forma segura de se determinar previamente a validade dos padrões de referência, por isso a avaliação da estabilidade dos padrões durante o período de sua utilização é fundamental para garantir a confiabilidade dos resultados. Sendo assim, é importante um estudo mais aprofundado frente às condições de armazenamento para posterior determinação do prazo de validade desses padrões. O estudo teve como objetivo avaliar a estabilidade de nove lotes das matérias-primas candidatas a padrão secundário avaliando três fabricantes diferentes frente a duas condições de armazenamento (dessecador e geladeira), através do monitoramento de seus teores de ativo e substâncias relacionadas ao longo de um ano. Para a caracterização da matéria-prima foram utilizadas técnicas termoanalíticas, espectroscópicas e difração de raios X de pó. As análises de teor e substâncias relacionadas foram realizadas utilizando HPLC. Com a caracterização confirmou-se que as amostras apresentavam o polimorfo mais estável (polimorfo I) na forma anidra. As análises cromatográficas apresentaram resultados dentro das especificações da matéria-prima, exceto duas amostras que apresentaram resultado de teor fora do especificado no último mês do estudo. Em relação ao teste de teor, catorze amostras devem ser repadronizadas antes de um ano, pois apresentaram uma variação máxima de DPR (desvio padrão relativo) de 0,5% para teores acima de 98%. No teste de substâncias relacionadas, todas as amostras apresentaram um total de impurezas de aproximadamente 0,1% ao longo do estudo de estabilidade, exceto três amostras cujo esse total foi de aproximadamente 0,3%. Em relação ao acondicionamento da matéria-prima candidata a padrão foram poucas as variações observadas nos testes de perda por secagem e titulação de Karl Fischer. Além disso, não houve grande diferença nos testes de teor e de substâncias relacionadas quando comparadas as duas condições de armazenamento. Portanto, a melhor condição de armazenamento do IFA de efavirenz é em dessecador (18 a 25ºC e UR < 75%) e o fabricante B é o melhor candidato a padrão secundário, pois foi o que apresentou menor teor de impurezas totais e individuais, e menores variações no teor e na perda por secagem. / Infection with human immunodeficiency virus (HIV) commonly known as AIDS, is one of the most serious infectious diseases in the world and a major challenge to public health. Although there is no treatment to eradicate the infection, the use of antiretrovirals is the best option for viral suppression.Efavirenz is a non-nucleoside reverse transcriptase inhibitor and the third most used in antiretroviral treatment due to its pharmacological properties and high potency in vivo. According to the Agência Nacional de Vigilância Sanitária (ANVISA), official reference standards must be used whenever they exist, and in the absence of these, reference standards properly characterized (secondary standards) should be used. There is no sure way to determine, previously, in advance the validity of reference standards. Thus, the
evaluation of the stability of these reference standards during the period of use is critical to ensure the reliability of results. Therefore, it is important to conduct further
studies exploring the storage conditions for later determination of validity of these
standards.The study aims to evaluate the stability of nine batches of raw materials
candidates for secondary standard evaluating three different manufacturers under two storage conditions (desiccant and refrigerator), by monitoring their assay and related substances over a year.For the characterization of the raw material thermoanalytical techniques, spectroscopic techniques and powder diffraction X-ray were used. The assayand related substances analysis were performed using
HPLC.With the characterization analysis confirmed that the samples had the most
stable polymorph (polymorph I) in the anhydrous form. The chromatographic analysis showed results within the specifications of the raw material, except two samples that presented results outside the specified in the assay at the last month of study. In this test, fourteen samples should undergo a new round of characterization before a year because has had a maximum variation of DPR (standard deviation) of 0.5% for contents above 98%. In related substances test, all samples exhibited results of total impurities of approximately 0.1% throughout the study of stability, except for three samples: the total amount was approximately 0.3%.Regarding the storage conditions of the standard few variations were observed in tests of loss on drying and Karl
Fischer titration. Furthermore, there are no great difference in assay and related
substances tests when compared to the two storage conditions.So, the best storage
condition of efavirenz standard is in desiccant (18 to 25°C and RH <75%) and the manufacturer B is the best candidate for secondary standard because it showed the lowest results of total and individual impurities with minor variations in assay and loss on drying.
|
534 |
Estudo de degradação forçada, desenvolvimento e validação de método analítico de teor e substâncias relacionadas para avaliação da estabilidade de comprimidos de leflunomida / Forced degradation study, analytical method development and validation for content and related substances evaluate the stability of leflunomide tabletsCaldeira, Alisson Samuel Portes January 2014 (has links)
Made available in DSpace on 2016-06-23T12:15:53Z (GMT). No. of bitstreams: 2
13.pdf: 3290087 bytes, checksum: c2534f744ed7289fbdbed582eaabac44 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2014 / Made available in DSpace on 2016-07-05T22:38:02Z (GMT). No. of bitstreams: 3
13.pdf.txt: 358391 bytes, checksum: 4a43403217e6829dc1ae5000589499cf (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
13.pdf: 3290087 bytes, checksum: c2534f744ed7289fbdbed582eaabac44 (MD5)
Previous issue date: 2014 / Fundação Oswaldo Cruz. Instituto de Tecnologia em Fármacos/Farmanguinhos. Rio de Janeiro, RJ, Brasil. / A leflunomida (LF) é um pró-fármaco antireumático pertencente ao grupo de fármacos modificadores do curso da doença, sendo empregada no tratamento da artrite reumatóide. Encontram-se disponíveis no mercado e medicamentos referência ARAVA produzido pela empresa Sanofi Aventis e as versões genéricas fabricadas pelas indústrias farmacêuticas Aché, Biosintética, Cristália, Marinha do Brasil e Zodiac. Para registro de um produto farmacêutico no Brasil, deve-se seguir as exigências da Agência Nacional de Vigilância Sanitária, que requer, dentre vários documentos, o estudo de estabilidade do medicamento e questão. Este estudo deve incluir diversos testes, sendo que a determinação do teor do fármaco e suas substâncias relacionadas são fundamentais para se compreender e determinar o prazo de validade de um produto. O objetivo deste trabalho foi desenvolver e validar uma metodologia analítica de teor e substâncias que permitisse avaliar a estabilidade dos comprimidos de L.F. Foram realizados estudos de degradação forçada no insumo farmacêutico ativo e no protótipo de comprimidos de L.F. proposto pela Fundação Ezequiel Dias (FUNED), empregando a hidrólise ácida, hidrólise alcalina, oxidação, degradação térmica e fotolítica. As amostras degradadas deram subsídio para o desenvolvimento e validação de um método, por cromatografia a líquido de alta eficiência, para determinação do teor e suas substâncias relacionadas. Uma coluna C18 (125x4,0mm, 5µm, a 25° graus Celcius), uma fase móvel em eluição, gradiente de acetato de amônio 10mM:acetonitrila (0 min-70:30; 15min-20:80; 16min-70:30 e 20 min-70:30) e um detector no ultravioleta (261nm) foram empregados para se atingir uma resolução adequada na separação da L.F. e suas substâncias relacionadas. Foram realizados os testes de degradação forçada, sendo que a hidrólise básica gerou apenas um produto de degradação (r=0,33), enquanto a ácida proporcionou o surgimento de dois(r=0,33 e 0,77); onze substâncias surgiram após a oxidação (r=0,16; 0,21; 0,41; 0,48; 0,58; 0,64; 0,67; 0,73; 0,78; 0,82 e 0,86). O método em eluição gradiente foi então validado de acordo com as diretrizes da RE n° 899 de 05/2003 da ANVISA e do DOQ-CGCRE-008 do INMETRO. A linearidade, na faixa de 10-60 µg/mL, foi demonstrada utilizando ANOVA (Fcalculado < Fcrítico). Comprovou-se as precisões intra-corrida (DPR≤3,3%) e intra-corrida (DPR≤5,0%) nas concentrações de 20; 40 e 60 µg/mL aplicando ANOVA. A exatidão variou de 98, 30% a 102,36% e a robustez foi satisfatória em todas as condições avaliadas. Aestabilidade dos comprimidos de LF, nas embalagens blíster de cloreto de polivinilideno e frasco de polietileno, foi então avaliada utilizando o método validado, sendo que em ambas foram quantificados os produtos da hidrólise alcalina (r=0,33) e da hidrólise ácida (r=0,77). Os resultados do estudo de estabilidade da formulação foram insatisfatórios para a LF devido à queda no seu teor superior a 5% no estudo acelerado e de longa duração em ambas embalagens. Pode-se concluir que o método indicativo de estabilidade foi desenvolvido e validado com sucesso para a quantificação do teor e substâncias relacionadas. Portanto, este método pode ser empregado na indústria farmacêutica tanto para o controle de qualidade quanto para avaliação dos estudos de estabilidade de comprimidos de LF. / Leflunomide (LF) is a prodrug of the disease-modifying antirheumatic drug (DMARD) used in rheumatoid arthritis. It is commercially available in tablet presentations of 10, 20 and 100 mg. The reference drug ARAVA reference manufactured by Sanofi Aventis and generic versions manufactured by pharmaceutical companies Aché, Biosintética, Cristália, Brazil's Navy and Zodiac are available in the market. For registration of a pharmaceutical product in Brazil it must follow the requirements of Agência Nacional de Vigilância Sanitária, which demands, among many documents, the stability study of the product concerned. This study should include several tests, and the determination of drug content and its related substances are fundamental to determine the shelf life of a product. The aim of this study was to develop and validate an assay and related substances analytical methodology that allow to evaluating the stability of the LF tablets. Forced degradation were perfomed on active pharmaceutical ingredient and LF tablets prototype proposed by FUNED, employing acid hydrolysis, alkaline hydrolysis, oxidation, photolytic and thermal degradation. The degraded samples allowed the development and validation of a liquid chromatography high efficiency method to determine the drug and its related substances. A C18 column (125x4,0mm, 5μm, 25 ° Celcius), a gradiente mobile phase of 10mM ammonium acetate: acetonitrile (0 min-70: 30; 15 min, 20: 80; 16min-70: 30 and 20 min-70: 30), and a ultraviolet detector (261nm) were used to achieve adequate resolution in the separation of LF and its related substances. Forced degradation test waere performed, which generated only one basic hydrolysis degradation product (r = 0.33), while the acidic gave the rise of two (r = 0.33 and 0.77); eleven substances arose after oxidation (r = 0.16; 0.21; 0.41; 0.48; 0.58; 0.64; 0.67; 0.73; 0.78; 0.82 and 0 , 86). The gradient method was then validated accordance to ANVISA RE No. 899 05/2003 and INMETRO DOQ-CGCRE-008 guidelines. The linearity in the range of 10-60 mg / mL was demonstrated using ANOVA (Fcalculado <Fcrítico). Intra-run precisions (DPR≤3,3%) and intra-run (DPR≤5,0%) at concentrations of 20; 40 and 60 ug / ml were satisfatory by applying ANOVA. The accuracy ranged from 98, 30% to 102.36% and robustness was satisfactory in all conditions evaluated. The stability of LF tablets polyvinylidene chloride blister and polyethylene vial packaging was then assessed using the validated method. Degradation products were found from alkaline hydrolysis (r = 0.33) and acidic hydrolysis (r = 0.77). The stability results of the formulation were unsatisfactory for LF due to its content drop exceeding 5% in both packages on accelerated and long term studies. It can be concluded that stability indicating method has been successfully developed and validated for assay and related substances measurement. Therefore, this method can be used for both quality control and stability studies evaluation of LF tablets in the pharmaceutical industry.
|
535 |
Comparação interlaboratorial entre metodologias e estabilidade da amostra na dosagem do perfil lipídico e PCR-US / Interlaboratory comparison of methodologies and sample stability in the dosage of the lipid profile and hsCRPVania Penha Pinto Castro 26 February 2015 (has links)
Segundo O`Kane et al, em 2008, foi demonstrado que 88,9% dos erros laboratoriais são realizados na fase pré-analítica. No laboratório de análises clínicas, o sistema de controle da qualidade pode ser definido como toda a ação sistemática necessária para dar confiança e segurança em todos os exames e prevenir a ocorrência de erros. O tempo de armazenamento pode variar de dias a meses ou mesmo anos, influenciando na definição da temperatura de estocagem. O armazenamento de longo prazo pode resultar na criopreservação inadequada para determinados analitos e pode desnaturar as lipoproteínas. Objetivos: Este trabalho teve como objetivo avaliar a fase pré-analítica, controle da qualidade interno e também avaliar o efeito do congelamento (- 80C) quanto ao tempo de armazenamento do soro e plasma de sangue colhido com ácido etilenodiamino tetra-acético (EDTA). As dosagens foram realizadas no Laboratório de Lípides LabLip, e estocadas em - 80 C por três anos, as mesmas foram redosadas no Serviço de Patologia Clínica da Policlínica Piquet Carneiro da UERJ com metodologias iguais e realizada a comparabilidade dos resultados. Foram analisados o perfil lipídico (CT, HDLc e TG) e PCR-US de 103 amostras, 73 no soro e 30 no plasma em dois laboratórios altamente qualificados. Discussão: Após redosagem foram encontrados nas dosagens de HDLc e CT resultados diminuídos respectivamente (correlação coeficiente no soro 0,48 e 0,62) teste t pareado no soro (CT p 0,0012 e HDLc p 0,0001). Conclusões: Os dados obtidos nas avaliações dos resultados de diferentes laboratórios e tempo de estocagem revelaram que as amostras quando armazenadas por um longo período após redosagem no soro, apresentaram diferenças em certos analitos, tais como CT e HDLc, no qual obteve-se resultados significativamente diminuídos, diferentemente no plasma, que após três anos de estocagem a -80C foram redosados e aplicados no teste t pareado, os analitos CT e PCR-US mantiveram a estabilidade. / According O`Kane et al in 2008, it was demonstrated that 88.9% of the laboratory errors are made in the pre-analytical phase. In the clinical laboratory, quality control system can be defined as any systematic action needed to give confidence and security in all examinations and prevent the occurrence of errors. The storage time can vary from days to months or even years, influencing the definition of storage temperature. The long-term storage can result in inadequate cryopreservation for certain analytes can denature and lipoproteins. This study aimed to evaluate the pre-analytical phase, internal quality control and also evaluate the effect of freezing (- 80 C) and the serum storage time and plasma blood collected with ethylenediaminetetraacetic acid (EDTA) . The measurements were performed in Lipids Laboratory - LabLip, and stored in - 80 C for three years, they were re-dosed at the Clinical Pathology Department of Polyclinic Piquet Carneiro da UERJ with the same methodologies and held the comparability of results. We analyzed the lipid profile (TC, HDL-C and TG) and hsCRP 103 samples, 73 serum and 30 plasma in two highly qualified laboratories. After redosagem were found in dosages of HDL-C and CT results decreased respectively (correlation coefficient serum 0.48 and 0.62) paired t test serum (CT p 0.0012 and HDLc p 0.0001). The data obtained in the evaluation of results of different laboratories and storage time showed that the samples kept for a long period after redosagem serum, showed differences in certain analytes, such as CT and HDLc, which gave results significantly decreased, unlike in the plasma, which after three years of storage at -80 C were applied in redosados and paired t-test analytes CT and hsCRP maintained stability.
|
536 |
Controle de sistemas com atrasos no tempo na presença de atuadores saturantesGhiggi, Ilca Maria Ferrari January 2008 (has links)
Neste trabalho, aborda-se o problema de estabilização de sistemas lineares com atrasos nos estados e sujeitos a ação de atuadores saturantes. Em particular, são propostos métodos para a síntese de leis de controle estabilizantes do tipo realimentação de estados, realimentação dinâmica de saída, bem como para a síntese de compensadores de "anti-windup" estáticos e dinâmicos. Como objetivo de síntese consideram-se duas possibilidades, que o sistema esteja livre ou não de perturbações. No primeiro caso, determina-se uma lei de controle estabilizante de tal forma a maximizar um conjunto de condições iniciais admissíveis D. No caso do conjunto D ser dado, a lei de controle estabilizante que se determina, deve garantir estabilidade assintótica do sistema em malha-fechada para toda condição inicial pertencente a D. No segundo caso, considerando-se os problemas de atenuação e tolerância à perturbação, as leis de controle são obtidas com o intuito de minimizar o ganho-L2 entre a perturbação e a saída regulada do sistema ou de maximizar o limite superior da norma L2 das perturbações admissíveis, para as quais garante-se que as trajetórias do sistema em malha-fechada permaneçam limitadas. Condições locais e globais de estabilização são obtidas a partir da teoria de Lyapunov e da modelagem por zona-morta da saturação, com a conseqüente aplicação de uma condição de setor generalizada. Em se tratando de sistemas contínuos, para que as condições obtidas sejam dependentes do atraso, combinam-se estas ferramentas com a representação do sistema através de sistema descritor. Já no caso de sistemas discretos, combinam-se estas duas ferramentas com a utilização do Lema de Finsler. A utilização destas ferramentas possibilita que as condições obtidas sejam na forma de desigualdades matriciais lineares (LMI's) ou quase lineares, permitindo assim, a formulação de problemas de otimização convexos. / In this work, we deal with the problem of stabilization of linear systems with delayed state and saturating inputs. Specifically, methods are proposed for the synthesis of stabilizing control laws of state feedback and dynamic output feedback types, as well as for the synthesis of static and dynamic anti-windup compensators. Regarding synthesis objectives two possibilities were considered, that the system is free or not of disturbances. In the first case, the stabilizing control law is computed considering the maximization of the set of admissible initial conditions D. In the case the set D is given, this stabilizing control law should guarantee asymptotic stability of the closed-loop system. In the second case, considering the problems of tolerance and disturbance attenuation, the control laws are proposed in order to minimize the L2 gain between to disturbance and the regulated output of system, or in order to maximize the bound on the admissible disturbances for which the trajectories are bounded. Local and global conditions for stabilization are obtained from the theory of Lyapunov and the modeling of the saturation by means of deadzone nonlinearities and the consequent application of a modified sector condition. For continuous systems, in order to obtain delay dependent conditions, these tools are combined with descriptor approach. In the case of discrete-time systems, these two tools are combined with the utilization of Finsler's Lemma. The use of these leads to the conditions in the form of Linear Matrix Inequalities (LMI's) or almost linear, allowing the formulation of convex optimization problems.
|
537 |
Comparação interlaboratorial entre metodologias e estabilidade da amostra na dosagem do perfil lipídico e PCR-US / Interlaboratory comparison of methodologies and sample stability in the dosage of the lipid profile and hsCRPVania Penha Pinto Castro 26 February 2015 (has links)
Segundo O`Kane et al, em 2008, foi demonstrado que 88,9% dos erros laboratoriais são realizados na fase pré-analítica. No laboratório de análises clínicas, o sistema de controle da qualidade pode ser definido como toda a ação sistemática necessária para dar confiança e segurança em todos os exames e prevenir a ocorrência de erros. O tempo de armazenamento pode variar de dias a meses ou mesmo anos, influenciando na definição da temperatura de estocagem. O armazenamento de longo prazo pode resultar na criopreservação inadequada para determinados analitos e pode desnaturar as lipoproteínas. Objetivos: Este trabalho teve como objetivo avaliar a fase pré-analítica, controle da qualidade interno e também avaliar o efeito do congelamento (- 80C) quanto ao tempo de armazenamento do soro e plasma de sangue colhido com ácido etilenodiamino tetra-acético (EDTA). As dosagens foram realizadas no Laboratório de Lípides LabLip, e estocadas em - 80 C por três anos, as mesmas foram redosadas no Serviço de Patologia Clínica da Policlínica Piquet Carneiro da UERJ com metodologias iguais e realizada a comparabilidade dos resultados. Foram analisados o perfil lipídico (CT, HDLc e TG) e PCR-US de 103 amostras, 73 no soro e 30 no plasma em dois laboratórios altamente qualificados. Discussão: Após redosagem foram encontrados nas dosagens de HDLc e CT resultados diminuídos respectivamente (correlação coeficiente no soro 0,48 e 0,62) teste t pareado no soro (CT p 0,0012 e HDLc p 0,0001). Conclusões: Os dados obtidos nas avaliações dos resultados de diferentes laboratórios e tempo de estocagem revelaram que as amostras quando armazenadas por um longo período após redosagem no soro, apresentaram diferenças em certos analitos, tais como CT e HDLc, no qual obteve-se resultados significativamente diminuídos, diferentemente no plasma, que após três anos de estocagem a -80C foram redosados e aplicados no teste t pareado, os analitos CT e PCR-US mantiveram a estabilidade. / According O`Kane et al in 2008, it was demonstrated that 88.9% of the laboratory errors are made in the pre-analytical phase. In the clinical laboratory, quality control system can be defined as any systematic action needed to give confidence and security in all examinations and prevent the occurrence of errors. The storage time can vary from days to months or even years, influencing the definition of storage temperature. The long-term storage can result in inadequate cryopreservation for certain analytes can denature and lipoproteins. This study aimed to evaluate the pre-analytical phase, internal quality control and also evaluate the effect of freezing (- 80 C) and the serum storage time and plasma blood collected with ethylenediaminetetraacetic acid (EDTA) . The measurements were performed in Lipids Laboratory - LabLip, and stored in - 80 C for three years, they were re-dosed at the Clinical Pathology Department of Polyclinic Piquet Carneiro da UERJ with the same methodologies and held the comparability of results. We analyzed the lipid profile (TC, HDL-C and TG) and hsCRP 103 samples, 73 serum and 30 plasma in two highly qualified laboratories. After redosagem were found in dosages of HDL-C and CT results decreased respectively (correlation coefficient serum 0.48 and 0.62) paired t test serum (CT p 0.0012 and HDLc p 0.0001). The data obtained in the evaluation of results of different laboratories and storage time showed that the samples kept for a long period after redosagem serum, showed differences in certain analytes, such as CT and HDLc, which gave results significantly decreased, unlike in the plasma, which after three years of storage at -80 C were applied in redosados and paired t-test analytes CT and hsCRP maintained stability.
|
538 |
Controle de sistemas com atrasos no tempo na presença de atuadores saturantesGhiggi, Ilca Maria Ferrari January 2008 (has links)
Neste trabalho, aborda-se o problema de estabilização de sistemas lineares com atrasos nos estados e sujeitos a ação de atuadores saturantes. Em particular, são propostos métodos para a síntese de leis de controle estabilizantes do tipo realimentação de estados, realimentação dinâmica de saída, bem como para a síntese de compensadores de "anti-windup" estáticos e dinâmicos. Como objetivo de síntese consideram-se duas possibilidades, que o sistema esteja livre ou não de perturbações. No primeiro caso, determina-se uma lei de controle estabilizante de tal forma a maximizar um conjunto de condições iniciais admissíveis D. No caso do conjunto D ser dado, a lei de controle estabilizante que se determina, deve garantir estabilidade assintótica do sistema em malha-fechada para toda condição inicial pertencente a D. No segundo caso, considerando-se os problemas de atenuação e tolerância à perturbação, as leis de controle são obtidas com o intuito de minimizar o ganho-L2 entre a perturbação e a saída regulada do sistema ou de maximizar o limite superior da norma L2 das perturbações admissíveis, para as quais garante-se que as trajetórias do sistema em malha-fechada permaneçam limitadas. Condições locais e globais de estabilização são obtidas a partir da teoria de Lyapunov e da modelagem por zona-morta da saturação, com a conseqüente aplicação de uma condição de setor generalizada. Em se tratando de sistemas contínuos, para que as condições obtidas sejam dependentes do atraso, combinam-se estas ferramentas com a representação do sistema através de sistema descritor. Já no caso de sistemas discretos, combinam-se estas duas ferramentas com a utilização do Lema de Finsler. A utilização destas ferramentas possibilita que as condições obtidas sejam na forma de desigualdades matriciais lineares (LMI's) ou quase lineares, permitindo assim, a formulação de problemas de otimização convexos. / In this work, we deal with the problem of stabilization of linear systems with delayed state and saturating inputs. Specifically, methods are proposed for the synthesis of stabilizing control laws of state feedback and dynamic output feedback types, as well as for the synthesis of static and dynamic anti-windup compensators. Regarding synthesis objectives two possibilities were considered, that the system is free or not of disturbances. In the first case, the stabilizing control law is computed considering the maximization of the set of admissible initial conditions D. In the case the set D is given, this stabilizing control law should guarantee asymptotic stability of the closed-loop system. In the second case, considering the problems of tolerance and disturbance attenuation, the control laws are proposed in order to minimize the L2 gain between to disturbance and the regulated output of system, or in order to maximize the bound on the admissible disturbances for which the trajectories are bounded. Local and global conditions for stabilization are obtained from the theory of Lyapunov and the modeling of the saturation by means of deadzone nonlinearities and the consequent application of a modified sector condition. For continuous systems, in order to obtain delay dependent conditions, these tools are combined with descriptor approach. In the case of discrete-time systems, these two tools are combined with the utilization of Finsler's Lemma. The use of these leads to the conditions in the form of Linear Matrix Inequalities (LMI's) or almost linear, allowing the formulation of convex optimization problems.
|
539 |
Aplicações de Modelos de Grafos na Análise de Conflitos e de Redes SociaisSANTOS, Andréa Maria dos 02 1900 (has links)
Submitted by Etelvina Domingos (etelvina.domingos@ufpe.br) on 2015-03-12T19:49:50Z
No. of bitstreams: 2
TESE Andréa Maria dos Santos.pdf: 1395295 bytes, checksum: c74340b3ee12caded00ab3ab4499784f (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-12T19:49:50Z (GMT). No. of bitstreams: 2
TESE Andréa Maria dos Santos.pdf: 1395295 bytes, checksum: c74340b3ee12caded00ab3ab4499784f (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Previous issue date: 2014-02 / Muitos modelos têm sido criados em Teoria dos Jogos para representar diferentes interações
sociais. As ferramentas utilizadas em cada modelo visam representar de maneira
mais adequada as particularidades de cada situação do mundo real. Existem algumas
formas básicas de se representar um jogo, porém, dada a complexidade de modelar algumas
situações é interessante obter novas formas de representação de jogos e de análise
de comportamento dos envolvidos em um jogo. Esta tese pode ser dividida em duas partes
independentes. Na primeira, apresentamos generalizações do modelo de grafos para
resolução de conflitos, introduzindo a possibilidade de indivíduos tomadores de decisões
expressarem suas preferências com incerteza usando preferências probabilísticas. Neste
cenário, propomos definições de estabilidade para o conflito envolvendo dois ou mais tomadores
de decisão e mostramos aplicações do modelo generalizado. Na segunda parte,
analisamos redes sociais com pesos nas ligações, propondo uma nova definição de utilidade
para rede de coautores e apresentando resultados sobre eficiência e estabilidade de
tais redes.
|
540 |
Sistemas de Filippov em variedades tridimensionais / Phippov systems in tridimensional manifoldsTonon, Durval José 15 August 2018 (has links)
Orientador: Marco Antonio Teixeira / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Matematica, Estatistica e Computação Cientifica / Made available in DSpace on 2018-08-15T04:08:50Z (GMT). No. of bitstreams: 1
Tonon_DurvalJose_D.pdf: 2611537 bytes, checksum: 3c2c9e68c38b852842efbce1837a1b68 (MD5)
Previous issue date: 2010 / Resumo: Neste trabalho sistemas dinâmicos descontínuos em variedades tridimensionais são estudados. Descrevemos uma classe de tais sistemas que são localmente estruturalmente estáveis em uma vizinhança de uma singularidade típica. Exibimos nessa etapa uma sub-família de campos do tipo dobra-dobra que é estruturalmente estável. Introduzimos os conceitos de A e L-estabilidade, que são pequenas generalizações dos conceitos clássicos de estabilidade assintótica e estabilidade no sentido de Lyapunov, respectivamente. Através de formas normais para as famílias de campos descontínuos de codimensão zero e um, exibimos os subconjuntos de sistemas descontínuos que são A e L-estáveis em uma vizinhança da origem. Destacamos um dos principais objetos de estudo desse trabalho: a singularidade dobra-dobra caso elíptico (T-singularidade). Discutimos algumas propriedades de sua dinâmica como a A-estabilidade para campos do tipo dobra-dobra de codimensão zero, um e dois. Investigamos também a presença de alguns invariantes topológicos, como separatrizes e famílias de órbitas periódicas. Finalmente, analisamos os chamados sistemas com relê. Em especial um sistema com dois relês acoplados é discutido. / Abstract: In this work non-smooth dynamical systems in IR are considered. We describe a class of such systems that are locally structurally stable around a typical singularity. One of our contributions is to exhibit within these class of fold-fold systems a subclass which is structural stable. We also introduce the concept of A and L-stability which generalizes the classical concept of asymptotic and Lyapunov stability, respectively. Using normal forms for families of non smooth dynamical systems of codimension zero and one we exhibited subsets of non smooth dynamical systems which are A and L-stable in a neighborhood of the origin. We emphasize that the main object of study within this work is the fold-fold singularity in the elliptical case (T-singularity). We discuss some of its dynamical properties such as A-stability for codimension zero, one and two systems. We also investigate the presence of topological invariants such as séparatrices and families of periodic orbits. Finally we analyze two coupled relay systems. / Doutorado / Sistemas Dinamicos / Doutor em Matemática
|
Page generated in 0.1039 seconds