• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 54
  • Tagged with
  • 55
  • 39
  • 29
  • 23
  • 11
  • 9
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Parâmetros hemodinâmicos, ventilatórios e intracranianos, em suínos anestesiados com isofluorano ou propofol, mantidos sob ventilação espontânea e fio2 de 0,5 /

Ido, Cléber Kazuo. January 2016 (has links)
Orientador: Newton Nunes / Banca: Danielli Parrilha de Paula / Banca: Roberto Thiesen / Resumo: Com esse estudo procurou-se avaliar comparativamente a anestesia total intravenosa pelo propofol e a anestesia geral inalatória pelo isofluorano e determinar qual modalidade anestésica foi mais vantajosa à dinâmica cardiorrespiratória, bem como sobre parâmetros intracranianos, em suínos recebendo FiO2 de 0,5 sob ventilação espontânea. Para tanto foram utilizados 16 animais machos ou fêmeas, distribuídos aleatoriamente em dois grupos de igual número: GI (Isofluorano e FiO2=0,5) e GP (Propofol e FiO2=0,5). Para todos os suínos, empregou-se como medicação pré-anestésica azaperona (2 mg/kg). Em ambos os grupos, os animais foram induzidos com propofol pela via intravenosa, na dose necessária para intubação orotraqueal. No grupo GI, após a intubação orotraqueal dos animais, o vaporizador foi ajustado para 1,5 CAM. No grupo GP, a manutenção anestésica foi realiza com propofol na taxa de 0,5 mg/kg/min. Em ambos os grupos, os parâmetros hemodinâmicos, ventilatórios e intracranianos foram avaliados 40 minutos após a indução da anestesia (M0), seguida de novas mensurações em intervalos de 15 minutos (de M15 a M60). Os resultados das variáveis paramétricas foram analisados pelo software SAS 9.1 (2010). De todos os parâmetros avaliados, houve diferença entre grupos nas variáveis respiratórias (PvO2, Hbv, ETCO2, f, Vt e Tins), cardiovasculares (PAS e IRPT) e intracranianos (PIC, PPC e TIC). Com relação aos momentos dentro do mesmo grupo, houve diferença no GI para as variáveis respiratória... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the present study was to compare the cardiorrespiratory dynamics as well as the intracranial parameters of piglets anesthetized with either total intravenous anesthesia with propofol or inhalation anesthesia with isoflurane and receiving FiO2 of 0,5 and kept under spontaneous ventilation. To that purpose, sixteen animals, males or females, were randomly divided into two groups: GI (Isoflurane and FiO2=0,5) and GP (Propofol and FiO2=0,5). For all pigs, azaperone (2 mg/kg) was used as premedication. In both groups, the animals were induced with intravenous administration of propofol, at the required dose for endotracheal intubation. In GI, after endotracheal intubation, the vaporizer was adjusted to 1.5 MAC. In GP, the maintenance of anesthesia was performed with constant rate infusion of propofol, at rate of 0,5 mg/kg/min. In both groups, hemodynamic, ventilatory and intracranial parameters were evaluated 40 minutes after anesthetic induction (M0), followed by 15-minutes intervals (M15 to M60). The results of parametric variables were analyzed by SAS 9.1 software (2010). In all parameters, there were differences between groups in the respiratory (PvO2, Hbv, PETCO2, f, Vt and Tins), cardiovascular (SBP and TPRI) and intracranial variables (ICP, CPP and ICT). Regarding moments in the same group, there were differences in GI in the respiratory (PaCO2, pH, PvO2, ETCO2, Vm, PAO2 and P(A-a)O2) and intracranial variables (TIC). In GP, significantly differed the pH, PvCO2, ... (Complete abstract click electronic access below) / Mestre
22

Avaliação do conhecimento sobre o uso de inaladores dosimetrados entre profissionais de saúde de um hospital pediátrico / Evaluation of the knowledge of health professionals at a pediatric hospital regarding the use of metered-dose inhalers

Muchão, Fabio Pereira 06 April 2009 (has links)
Existem evidências na literatura de que a administração de medicações, como corticosteróides inalatórios e broncodilatadores, utilizando inaladores pressurizados dosimetrados, é mais eficaz e segura do que com os nebulizadores convencionais. Entretanto, há evidências de que não só pacientes, mas também profissionais de saúde têm dificuldade no manejo dos inaladores pressurizados dosimetrados. A hipótese do presente estudo é que o conhecimento da técnica inalatória entre os profissionais da nossa Instituição é heterogêneo, sendo que não há informações sobre o nível deste conhecimento entre as diversas categorias profissionais. OBJETIVOS: Avaliar o conhecimento prático e teórico de profissionais da área médica, de enfermagem e fisioterapia sobre a utilização do inalador dosimetrado através de testes padronizados. MÉTODOS: Avaliações teóricas e práticas sobre o conhecimento do uso de inaladores pressurizados dosimetrados foram realizadas com médicos, fisioterapeutas, enfermeiras e auxiliares de enfermagem, atribuindo-se uma nota de 0 a 10 para cada avaliação. Calcularam-se as medianas das notas obtidas pelos profissionais de cada categoria, as questões com maiores e menores índices de erros e feita a comparação descritiva do desempenho das diversas categorias profissionais. Após as avaliações, instrução verbal e escrita sobre a utilização correta dos dispositivos foi fornecida a todos os participantes. A análise estatística foi feita através do método de Kruskal-Wallis de comparação de medianas. Também foi realizada a análise através de regressão logística múltipla seqüencial. RESULTADOS: foram avaliados 30 médicos residentes ou estagiários da pediatria, 23 médicos assistentes, 29 fisioterapeutas, 33 enfermeiras e 31 auxiliares de enfermagem, em um total de146 profissionais. Não foram entrevistados residentes ou assistentes do grupo de Pneumologia. Os médicos residentes, fisioterapeutas e os médicos assistentes obtiveram desempenho significativamente superior que os enfermeiros e auxiliares de enfermagem. Apenas os médicos residentes obtiveram mediana superior a seis. As questões práticas com maiores índices de erros foram as relativas à limpeza do espaçador. Questões relativas à agitação do inalador antes do uso e à limpeza da cavidade oral após a sua utilização também obtiveram alto índice de erros. A questão teórica mais errada foi a respeito do tempo necessário entre dois jatos em aplicações sucessivas do inalador pressurizado dosimetrado. CONCLUSÕES: O conhecimento teórico-prático dos profissionais de saúde da Instituição a respeito do uso de inaladores pressurizados dosimetrados é heterogêneo. Os médicos residentes, fisioterapeutas e médicos assistentes obtiveram desempenho significativamente melhor que os enfermeiros e auxiliares de enfermagem sendo que estes últimos estão diretamente envolvidos na aplicação prática destes dispositivos na rotina hospitalar. / There are data in the literature indicating that the administration of medications such as inhaled corticosteroids and bronchodilators, using metered-dose inhalers, is more effective and safer than its dispensation by conventional nebulizers. However, there is evidence that not only patients but also health care professionals have difficulty in dealing with pressurized dose inhalers. The hypothesis of the present study is that the knowledge of inhalation techniques among health professionals of our Institution is heterogeneous, and there is no information about this knowledge among the diverse categories of professionals. OBJECTIVE: To assess the practical and theoretical knowledge of medical professionals, nursing and physiotherapy on the use of metereddose inhalers by standardized testing. METHODS: Practical and written tests on the use of metered-dose inhalers were applied to physicians, physical therapists, nurses and nursing assistants. A score from 0 to 10 was assigned to each evaluation. Median scores were calculated for each professional category. Questions with higher and lower correct values were identified, and a descriptive comparison was made regarding the performance of the diverse professional categories. Following the examination, oral and written instructions on the correct use of the devices were provided for all participants. Statistical analysis was performed using the Kruskal-Wallis method for comparison of medians. A sequential logistic multiple regression analysis was also performed. RESULTS: A total of 146 professionals were assessed, including 30 fellows in pediatrics, 23 attending physicians, 29 physical therapists, 33 nurses and 31 nursing assistants. Fellows or attending physicians of the Pediatric Pulmonology Unit were not included in the study. Fellows, physical therapists and attending physicians performed significantly better than did nurses and nursing assistants. Only fellows had a median score greater than six. On the practical tests for infants and toddlers, the step most often missed was that related to cleaning the spacer. On practical tests, the steps related to shaking the inhaler and cleaning the mouth also presented high error indices. On the written tests, the question most often answered incorrectly was that related to the waiting time between puffs. CONCLUSIONS: The theoretical and practical knowledge of health professionals of our Institution on the use of metered-dose inhalers is heterogeneous. The performance of fellows, physical therapists and attending physicians was significantly better than that of nurses and nursing assistants who are directly involved in the practical application of these devices in the hospital routine.
23

Comparação entre a variação da pressão de pulso e o índice de variabilidade pletismográfica como índices dinâmicos de pré-carga em cães anestesiados com isoflurano submetidos à hemorragia hipotensiva por reposição volêmica /

Klein, Adriana Vieira. January 2015 (has links)
Orientador: Francisco José Teixeira Neto / Banca: Paulo do Nascimento Junior / Banca: Suzane Lilian Beier / Resumo: Klein, A. V. Comparação entre a variação da pressão de pulso e o índice de variabilidade pletismográfica como índices dinâmicos de pré-carga em cães anestesiados com isoflurano submetidos à hemorragia hipotensiva seguida por reposição volêmica. 72 p. Dissertação (Mestrado) - Faculdade de Medicina, Universidade Estadual Paulista, Botucatu, 2015. A variação da pressão de pulso (VPP) e índice de variabilidade pletismográfica (IVP) são parâmetros úteis para identificar os indivíduos onde o aumento da pré-carga obtido pela expansão volêmica resultará em elevação do índice sistólico (IS) e do índice cardíaco (IC). Este estudo objetivou comparar a VPP e o IVP como índices dinâmicos de pré-carga em cães anestesiados com isoflurano submetidos à hemorragia hipotensiva, seguida pela reposição volêmica (RV) com sangue autólogo. Em um estudo prospectivo, sete cães adultos pesando 25,1 ± 3,4 kg (média ± desvio padrão) foram anestesiados com isoflurano e submetidos à ventilação com volume controlado (volume corrente: 12 mL/kg) com o emprego do bloqueador neuromuscular atracúrio. As concentrações expiradas de isoflurano, ajustadas para manter a pressão arterial média (PAM) em 65 mmHg (±5 mmHg de variação) antes da hemorragia, foram mantidas constantes durante o estudo. O débito cardíaco foi obtido através da técnica de termodiluição pulmonar, enquanto a VPP e o IVP foram obtidos através da pressão arterial invasiva e através de um sensor de oxímetro de pulso posicionado na língua, respectivamente. As variáveis estudadas foram coletadas antes da hemorragia (momento basal), após a retirada de sangue até a redução da PAM para 45 mmHg (± 5 mmHg de variação) e após a RV com sangue autólogo durante 30 minutos. A hemorragia diminuiu significativamente (P < 0,05) o IS e o IC em relação ao momento basal, enquanto a RV normalizou estas variáveis. A VPP e o IVP aumentaram... / Abstract: Klein, A. V. Comparison of changes in pulse pressure variation and in plethysmographic variability index induced by hypotensive hemorrhage followed by volume replacement in isoflurane-anesthetized dogs. 72 p. Dissertation (MSc) - School of Medicine, São Paulo State University, Botucatu, 2015. The pulse pressure variation (PPV) and the pletysmographic variability index (IVP) are parameters that may identify individuals in which an increase in preload achieved by volume expansion will result in an increase in stroke index (SI) and in cardiac index (CI). This study aimed to compare the PPV and the PVI as dynamic preload indexes in isoflurane-anesthetized dogs undergoing hypotensive hemorrhage followed by volume replacement (VR) with autologous blood. In a prospective study, seven adult dogs weighing 25,1 ± 3,4 kg (mean ± standard deviation) were anesthetized with isoflurane under volume controlled ventilation (tidal volume: 12 mL/kg) and atracurium neuromuscular blockade. End-tidal isoflurane concentrations, adjusted to maintain mean arterial pressure (MAP) at 65 mmHg (± 5 mmHg range) before hemorrhage, were maintained constant throughout the study. Cardiac output was measured by the pulmonary thermodilution technique, while PPV and PVI were derived from invasive blood pressure from a pulse oxymeter placed in the tongue, respectively. Variables were recorded before hemorrhage (baseline), after withdrawing blood until MAP was decreased to 45 mmHg (± 5 mmHg range), and after VR with autologous blood over 30 minutes. Hemorrhage significantly (P < 0.05) decreased SI and CI from baseline; while VR normalized these variables. The PPV and PVI significantly increased from baseline after hemorrhage. Changes from baseline induced by hemorrhage were significantly higher for PPV (11 ± 5%) than for PVI (5 ± 5%). After VR, PPV returned to baseline while PVI decreased significantly from baseline. Changes from hemorrhage induced by VR were ... / Mestre
24

Avaliação do conhecimento sobre o uso de inaladores dosimetrados entre profissionais de saúde de um hospital pediátrico / Evaluation of the knowledge of health professionals at a pediatric hospital regarding the use of metered-dose inhalers

Fabio Pereira Muchão 06 April 2009 (has links)
Existem evidências na literatura de que a administração de medicações, como corticosteróides inalatórios e broncodilatadores, utilizando inaladores pressurizados dosimetrados, é mais eficaz e segura do que com os nebulizadores convencionais. Entretanto, há evidências de que não só pacientes, mas também profissionais de saúde têm dificuldade no manejo dos inaladores pressurizados dosimetrados. A hipótese do presente estudo é que o conhecimento da técnica inalatória entre os profissionais da nossa Instituição é heterogêneo, sendo que não há informações sobre o nível deste conhecimento entre as diversas categorias profissionais. OBJETIVOS: Avaliar o conhecimento prático e teórico de profissionais da área médica, de enfermagem e fisioterapia sobre a utilização do inalador dosimetrado através de testes padronizados. MÉTODOS: Avaliações teóricas e práticas sobre o conhecimento do uso de inaladores pressurizados dosimetrados foram realizadas com médicos, fisioterapeutas, enfermeiras e auxiliares de enfermagem, atribuindo-se uma nota de 0 a 10 para cada avaliação. Calcularam-se as medianas das notas obtidas pelos profissionais de cada categoria, as questões com maiores e menores índices de erros e feita a comparação descritiva do desempenho das diversas categorias profissionais. Após as avaliações, instrução verbal e escrita sobre a utilização correta dos dispositivos foi fornecida a todos os participantes. A análise estatística foi feita através do método de Kruskal-Wallis de comparação de medianas. Também foi realizada a análise através de regressão logística múltipla seqüencial. RESULTADOS: foram avaliados 30 médicos residentes ou estagiários da pediatria, 23 médicos assistentes, 29 fisioterapeutas, 33 enfermeiras e 31 auxiliares de enfermagem, em um total de146 profissionais. Não foram entrevistados residentes ou assistentes do grupo de Pneumologia. Os médicos residentes, fisioterapeutas e os médicos assistentes obtiveram desempenho significativamente superior que os enfermeiros e auxiliares de enfermagem. Apenas os médicos residentes obtiveram mediana superior a seis. As questões práticas com maiores índices de erros foram as relativas à limpeza do espaçador. Questões relativas à agitação do inalador antes do uso e à limpeza da cavidade oral após a sua utilização também obtiveram alto índice de erros. A questão teórica mais errada foi a respeito do tempo necessário entre dois jatos em aplicações sucessivas do inalador pressurizado dosimetrado. CONCLUSÕES: O conhecimento teórico-prático dos profissionais de saúde da Instituição a respeito do uso de inaladores pressurizados dosimetrados é heterogêneo. Os médicos residentes, fisioterapeutas e médicos assistentes obtiveram desempenho significativamente melhor que os enfermeiros e auxiliares de enfermagem sendo que estes últimos estão diretamente envolvidos na aplicação prática destes dispositivos na rotina hospitalar. / There are data in the literature indicating that the administration of medications such as inhaled corticosteroids and bronchodilators, using metered-dose inhalers, is more effective and safer than its dispensation by conventional nebulizers. However, there is evidence that not only patients but also health care professionals have difficulty in dealing with pressurized dose inhalers. The hypothesis of the present study is that the knowledge of inhalation techniques among health professionals of our Institution is heterogeneous, and there is no information about this knowledge among the diverse categories of professionals. OBJECTIVE: To assess the practical and theoretical knowledge of medical professionals, nursing and physiotherapy on the use of metereddose inhalers by standardized testing. METHODS: Practical and written tests on the use of metered-dose inhalers were applied to physicians, physical therapists, nurses and nursing assistants. A score from 0 to 10 was assigned to each evaluation. Median scores were calculated for each professional category. Questions with higher and lower correct values were identified, and a descriptive comparison was made regarding the performance of the diverse professional categories. Following the examination, oral and written instructions on the correct use of the devices were provided for all participants. Statistical analysis was performed using the Kruskal-Wallis method for comparison of medians. A sequential logistic multiple regression analysis was also performed. RESULTS: A total of 146 professionals were assessed, including 30 fellows in pediatrics, 23 attending physicians, 29 physical therapists, 33 nurses and 31 nursing assistants. Fellows or attending physicians of the Pediatric Pulmonology Unit were not included in the study. Fellows, physical therapists and attending physicians performed significantly better than did nurses and nursing assistants. Only fellows had a median score greater than six. On the practical tests for infants and toddlers, the step most often missed was that related to cleaning the spacer. On practical tests, the steps related to shaking the inhaler and cleaning the mouth also presented high error indices. On the written tests, the question most often answered incorrectly was that related to the waiting time between puffs. CONCLUSIONS: The theoretical and practical knowledge of health professionals of our Institution on the use of metered-dose inhalers is heterogeneous. The performance of fellows, physical therapists and attending physicians was significantly better than that of nurses and nursing assistants who are directly involved in the practical application of these devices in the hospital routine.
25

Preparações para inalação : avaliação aerodinâmica das partículas finas

Carlos, Carla Isabel Amante January 2002 (has links)
No description available.
26

Efeitos cardiorrespiratórios promovidos pelo posicionamento trendelenburg reverso a cinco e dez graus em bezerros anestesiados pelo sevofluorano: Marcelo Augusto de Araújo. -

Araújo, Marcelo Augusto de [UNESP] 06 July 2015 (has links) (PDF)
Made available in DSpace on 2016-05-17T16:51:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-06. Added 1 bitstream(s) on 2016-05-17T16:54:47Z : No. of bitstreams: 1 000864322.pdf: 815216 bytes, checksum: c0bbfaacecea5919ee702fba6aa4553e (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / The aim of this study was to assess the cardiorespiratory effects of the reverse Trendelenburg position (RTP) at five and ten degrees in sevoflurane-anesthetized calves. Eight male Holstein calves aged 12±2 months were included in the study. At the first phase of the experiment, the minimum alveolar concentration of sevoflurane (MACsevo) was determined through electrical stimulation for each animal. At the second phase, the cardiorespiratory effects of the RTP were assessed. The subjects were restrained in dorsal recumbency on the surgical table tilted at 0° (G0), 5° (G5) or 10° (G10) in the reverse Trendelenburg position. Induction to anesthesia was produced with 8% sevoflurane in 5L/minute oxygen delivered through facial mask. The anesthesia was then maintained at 1.3 MACsevo. Cardiorespiratory variables were obtained after instrumentation (M40) and at 30, 60, 120 and 180 minutes (M70, M100, M160 and M220 respectively). The venous admixture was greater at M40 in G10 compared to G0 and G5. Oxygen consumption and extraction were significantly lower at M40 in G10 compared to G0 and G5, as well as at M100, M160 and M220 compared to G5 only. No differences were found between groups for the other variables. Reverse Trendelenburg position at five and ten degrees did not improve cardiorespiratory parameters in sevoflurane-anesthetized calves / FAPESP: 2013/06046-2
27

Avaliação de parâmetros bioquímicos e hematológicos em ratos wistar expostos à amônia por inalação

Orlandini, Lorena Floriani January 2012 (has links)
Embora a importância do controle dos níveis de amônia em biotérios seja reconhecida há muitos anos e várias consequências da exposição por inalação em espécies convencionais de laboratório sobre o trato respiratório tenham sido descritas na literatura, existem poucos estudos que avaliaram os efeitos sistêmicos e subclínicos nos animais. O presente trabalho teve por objetivo avaliar o perfil hematológico e bioquímico em ratos Wistar alojados sob condições ambientais adversas (ammonia build-up) com tempo de permanência de 5 (Grupo 1, n=20), 10 (Grupo 2, n=20) ou 15 dias (Grupo 3, n=20). A elevação dos níveis de poluentes no ambiente de alojamento experimental foi obtida através da redução da taxa de ventilação e da colocação de maravalha servida, de forma a alcançar-se uma concentração média aproximada de 90 ppm de amônia, variando de 76 a 106 ppm. A análise hematológica revelou que os animais do Grupo 1 apresentaram valores de hemoglobina e hematócrito significativamente maiores em relação todos os outros grupos. Com relação aos parâmetros bioquímicos, novamente observou-se que o Grupo 1 diferiu estatisticamente do Grupo Controle, do Grupo 2 e do Grupo 3 para creatinina e para gama-glutamiltransferase. Diferenças entre o Grupo 1 e os demais grupos experimentais foram encontradas para fosfatase alcalina, alanina aminotranferase, amilase e glicose. Os demais parâmetros apresentaram resultados variáveis e aparentemente inconclusivos. Concluindo, a análise dos resultados indica que a maioria das alterações no perfil hematológico e bioquímico de animais expostos ocorre entre o dia 0 e o dia 5 e posteriormente retorna aos valores basais, devido a uma possível resposta adaptativa ao aumento da concentração de amônia atmosférica no ambiente de alojamento. / Although the importance of controlling the levels of ammonia in animal facilities has been acknowledged for many years now, and several consequences of exposure by inhalation in conventional laboratory species on the respiratory tract have been described in the literature, there are few studies assessing the systemic and subclinical effects on animals. This study aimed at assessing the hematological and biochemical profile in Wistar rats housed under adverse environmental conditions (ammonia build-up) with stay time of 5 (Group 1, n=20), 10 (Group 2, n=20) or 15 days (Group 3, n=20). The increase in the levels of pollutants in the experimental environment housing was achieved by reducing the rate of ventilation and the placement of soiled bedding served, in order to achieve an average concentration of ammonia of approximately 90 ppm, ranging from 76 to 106 ppm. The hematological analysis revealed that animals in Group 1 had hemoglobin and hematocrit values significantly higher than all other groups. Concerning the biochemical parameters, once again it was observed that Group 1 differed statically from the Control Group, Group 2 and Group 3 regarding creatinine and gamma-glutamyltransferase. Differences between Group 1 and the other experimental groups were found regarding alkaline phosphatase, alanine aminotransferase, amylase and glucose. The other parameters showed variable results, apparently inconclusive. In conclusion, the analysis of the results indicates that most changes in the hematological and biochemical profile of the animals exposed occur between day 0 and day 5, and then return to baseline, in reason of a possible adaptive response to the increase of atmospheric ammonia concentration in the environment housing.
28

Análise de impactos das queimadas sobre a saúde humana: um estudo de caso do Município de Rio Branco, Acre / Analysis of impacts of fires on human health: a case study of the city of Rio Branco, Acre

Souza, Leonardo Salema Nogueira January 2008 (has links)
Made available in DSpace on 2012-09-06T01:12:18Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 1119.pdf: 1469120 bytes, checksum: 8eb738d0ea6e885db70370d7f6674016 (MD5) Previous issue date: 2008 / (...) O objetivo descreve e analisa a distribuição temporal dos focos de calor detectados por satélite e das hospitalizações por problemas respiratórios e circulatórios em crianças e idosos, respectivamente, residentes no município de Rio Branco, Acre, duante o período das queimadas entre 2000 e 2006. (...)
29

Efeitos hemodinâmicos, eletrocardiográficos e hemogasométricos do butorfanol em cães anestesiados pelo desfluorano

Santos, Paulo Sergio Patto dos [UNESP] 24 June 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-06-24Bitstream added on 2014-06-13T19:20:12Z : No. of bitstreams: 1 santos_psp_dr_jabo.pdf: 641424 bytes, checksum: 8c594a74557772feb6a9e2b096c91e94 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Avaliaram-se os efeitos hemodinâmicos, eletrocardiográficos e hemogasométricos decorrentes da aplicação do butorfanol em cães anestesiados pelo desfluorano. Utilizaram-se vinte cães adultos, machos e fêmeas, clinicamente saudáveis separados igualmente em dois grupos GP e GB e induzidos à anestesia com propofol, por via intravenosa, na dose de 8,4 l 0,8 mg/kg. Após a intubação com sonda orotraqueal de Magill, manteve-se a anestesia inalatória com desfluorano (10V%), diluído em O2 puro (30 mL/kg/min), através de circuito anestésico tipo semi fechado. Decorridos 40 minutos do início da anestesia inalatória foram administrados 0,05 mL/kg de solução de cloreto de sódio a 0,9% (placebo) ou 0,4 mg/kg de butorfanol, ambos por via intramuscular, respectivamente, aos animais do GP e GB. Considerou-se o período imediatamente anterior a estas aplicações como o momento zero (M0) para o registro dos parâmetros. Novas mensurações foram realizadas 15 minutos após (M15) e subseqüentemente a intervalos de 15 minutos, por um período de 60 minutos (M30, M45, M60 e M75). Os dados numéricos obtidos foram submetidos à Análise de Perfil, sendo considerado o nível de significância de p£0,05. A administração do butorfanol reduziu a freqüência cardíaca (FC), pressões arteriais sistólica (PAS), diastólica (PAD) e média (PAM), pressão média da artéria pulmonar (PAPm), resistência periférica total (RPT) e pressão de perfusão coronariana (PPC) ao longo de todo o período experimental. A pressão média do átrio direito (PADm) diminuiu em M30, M45 e M75 no GB quando comparado ao GP. O trabalho ventricular esquerdo (TVE) e índice do trabalho ventricular esquerdo (ITVE) diminuíram somente aos 15 minutos após a administração do opióide. Os intervalos RR e QT apresentaram valores de M0 menor que os demais no GB... . / The aim of this work was to evaluate alterations due to butorphanol administration in desflurane anesthetized dogs over hemodynamic, electrocardiography and blood gas analysis. Twenty adult dogs, males and females, clinically healthy, weighing 12l3 kg were used for this purpose. The dogs were separated in two groups (GP and GB) and general anesthesia was induced by intravenous administration of propofol (8.4l 0.8 mg/kg). All dogs were submitted to inhalatory anesthesia with desflurane (10V%), diluted in O2 (30 mL/kg/min), through a semi-closed anesthetic circuit. After 40 minutes of induction, animals from GP received saline solution at 0.9% (0.05 mL/kg) and from GB received butorphanol (0.4 mg/kg), both applied intramuscularly. Observations of the variables started immediately before the application of the agents (M0). Serial measurements were carried out in 15-minute intervals after the administration of butorphanol or saline up to 75 minutes, respectively M15, M30, M45, M60 and M75. Numeric data were submitted to profile analysis (p£0.05). Mean values for heart rate (HR), systolic (SAP), diastolic (DAP) and mean arterial pressure (MAP), mean pulmonary artery pressure (PAPm), total vascular resistance (TVR) and coronary perfusion pressure (CPP) were decreased after butorphanol administration. Mean right atrial pressure (RAPm) decreased at M30, M45 e M75 for GB when compared with GP and the left ventricular work (LVW) and left ventricular work index (LVWI) were significantly decreased 15 minutes after butorphanol administration. RR and QT intervals increased while the breathing rate (BR) decreased at M30. Mean values for PaCO2 and base deficit (BD) increased after butorphanol administration. Mean values for arterial pH were lower at M30, M45, M60 and M75 in GB when compared with GP and body temperature (T°C) gradually decreased for both groups... (Complete abstract, access undermentioned eletronic address)
30

Comparação entre a variação da pressão de pulso e o índice de variabilidade pletismográfica como índices dinâmicos de pré-carga em cães anestesiados com isoflurano submetidos à hemorragia hipotensiva por reposição volêmica / Comparison of changes in pulse pressure variation and in plethysmographic variability index induced hypotensive hemorrhage followed by volume replacement in isoflurane-anesthetized dogs

Klein, Adriana Vieira [UNESP] 27 February 2015 (has links) (PDF)
Made available in DSpace on 2015-08-20T17:09:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-27. Added 1 bitstream(s) on 2015-08-20T17:26:10Z : No. of bitstreams: 1 000840455.pdf: 703216 bytes, checksum: b7377910cd0cf18a9473841539933c24 (MD5) / Klein, A. V. Comparação entre a variação da pressão de pulso e o índice de variabilidade pletismográfica como índices dinâmicos de pré-carga em cães anestesiados com isoflurano submetidos à hemorragia hipotensiva seguida por reposição volêmica. 72 p. Dissertação (Mestrado) - Faculdade de Medicina, Universidade Estadual Paulista, Botucatu, 2015. A variação da pressão de pulso (VPP) e índice de variabilidade pletismográfica (IVP) são parâmetros úteis para identificar os indivíduos onde o aumento da pré-carga obtido pela expansão volêmica resultará em elevação do índice sistólico (IS) e do índice cardíaco (IC). Este estudo objetivou comparar a VPP e o IVP como índices dinâmicos de pré-carga em cães anestesiados com isoflurano submetidos à hemorragia hipotensiva, seguida pela reposição volêmica (RV) com sangue autólogo. Em um estudo prospectivo, sete cães adultos pesando 25,1 ± 3,4 kg (média ± desvio padrão) foram anestesiados com isoflurano e submetidos à ventilação com volume controlado (volume corrente: 12 mL/kg) com o emprego do bloqueador neuromuscular atracúrio. As concentrações expiradas de isoflurano, ajustadas para manter a pressão arterial média (PAM) em 65 mmHg (±5 mmHg de variação) antes da hemorragia, foram mantidas constantes durante o estudo. O débito cardíaco foi obtido através da técnica de termodiluição pulmonar, enquanto a VPP e o IVP foram obtidos através da pressão arterial invasiva e através de um sensor de oxímetro de pulso posicionado na língua, respectivamente. As variáveis estudadas foram coletadas antes da hemorragia (momento basal), após a retirada de sangue até a redução da PAM para 45 mmHg (± 5 mmHg de variação) e após a RV com sangue autólogo durante 30 minutos. A hemorragia diminuiu significativamente (P < 0,05) o IS e o IC em relação ao momento basal, enquanto a RV normalizou estas variáveis. A VPP e o IVP aumentaram... / Klein, A. V. Comparison of changes in pulse pressure variation and in plethysmographic variability index induced by hypotensive hemorrhage followed by volume replacement in isoflurane-anesthetized dogs. 72 p. Dissertation (MSc) - School of Medicine, São Paulo State University, Botucatu, 2015. The pulse pressure variation (PPV) and the pletysmographic variability index (IVP) are parameters that may identify individuals in which an increase in preload achieved by volume expansion will result in an increase in stroke index (SI) and in cardiac index (CI). This study aimed to compare the PPV and the PVI as dynamic preload indexes in isoflurane-anesthetized dogs undergoing hypotensive hemorrhage followed by volume replacement (VR) with autologous blood. In a prospective study, seven adult dogs weighing 25,1 ± 3,4 kg (mean ± standard deviation) were anesthetized with isoflurane under volume controlled ventilation (tidal volume: 12 mL/kg) and atracurium neuromuscular blockade. End-tidal isoflurane concentrations, adjusted to maintain mean arterial pressure (MAP) at 65 mmHg (± 5 mmHg range) before hemorrhage, were maintained constant throughout the study. Cardiac output was measured by the pulmonary thermodilution technique, while PPV and PVI were derived from invasive blood pressure from a pulse oxymeter placed in the tongue, respectively. Variables were recorded before hemorrhage (baseline), after withdrawing blood until MAP was decreased to 45 mmHg (± 5 mmHg range), and after VR with autologous blood over 30 minutes. Hemorrhage significantly (P < 0.05) decreased SI and CI from baseline; while VR normalized these variables. The PPV and PVI significantly increased from baseline after hemorrhage. Changes from baseline induced by hemorrhage were significantly higher for PPV (11 ± 5%) than for PVI (5 ± 5%). After VR, PPV returned to baseline while PVI decreased significantly from baseline. Changes from hemorrhage induced by VR were ...

Page generated in 0.0444 seconds