Magnetostatics and Dynamics of Ion Irradiated NiFe/Ta Multilayer Films Studied by Vector Network Analyzer Ferromagnetic Resonance

Markó, Daniel 31 January 2011 (has links) (PDF)
In the present work, the implications of ion irradiation on the magnetostatic and dynamic properties of soft magnetic Py/Ta (Py = Permalloy: Ni80Fe20) single and multilayer films have been investigated with the main objective of finding a way to determine their saturation magnetization. Both polar magneto-optical Kerr effect (MOKE) and vector network analyzer ferromagnetic resonance (VNA-FMR) measurements have proven to be suitable methods to determine µ0MS, circumventing the problem of the unknown effective magnetic volume that causes conventional techniques such as SQUID or VSM to fail. Provided there is no perpendicular anisotropy contribution in the samples, the saturation magnetization can be determined even in the case of strong interfacial mixing due to an inherently high number of Py/Ta interfaces and/or ion irradiation with high fluences. Another integral part of this work has been to construct a VNA-FMR spectrometer capable of performing both azimuthal and polar angle-dependent measurements using a magnet strong enough to saturate samples containing iron. Starting from scratch, this comprised numerous steps such as developing a suitable coplanar waveguide design, and writing the control, evaluation, and fitting software. With both increasing ion fluence and number of Py/Ta interfaces, a decrease of saturation magnetization has been observed. In the case of the 10×Py samples, an immediate decrease of µ0MS already sets in at small ion fluences. However, for the 1×Py and 5×Py samples, the saturation magnetization remains constant up to a certain ion fluence, but then starts to rapidly decrease. Ne ion irradiation causes a mixing and broadening of the interfaces. Thus, the Py/Ta stacks undergo a transition from being polycrystalline to amorphous at a critical fluence depending on the number of interfaces. The saturation magnetization is found to vanish at a Ta concentration of about 10–15 at.% in the Py layers. The samples possess a small uniaxial anisotropy, which remains virtually unaffected by the ion fluence, but slightly reduces with an increasing number of Py/Ta interfaces. In addition to magnetostatics, the dynamic properties of the samples have been investigated as well. The Gilbert damping parameter α increases with both increasing number of Py/Ta interfaces and higher ion fluences, with the former having a stronger influence. The inhomogeneous linewidth broadening ΔB0 increases as well with increasing number of Py/Ta interfaces, but slightly decreases for higher ion fluences. / In dieser Dissertation ist der Einfluss von Ionenbestrahlung auf die magnetostatischen und dynamischen Eigenschaften von weichmagnetischen Py/Ta-Einzel- und Multilagen (Py = Permalloy: Ni80Fe20) untersucht worden, wobei das Hauptziel gewesen ist, eine Methode zur Bestimmung der Sättigungsmagnetisierung zu finden. Sowohl polare magneto-optische Kerr-Effektmessungen (MOKE) als auch ferromagnetische Resonanzmessungen mittels eines Vektornetzwerkanalysators (VNA-FMR) haben sich als geeignet erwiesen, um µ0MS zu bestimmen, wobei das Problem des unbekannten effektiven magnetischen Volumens umgangen wird, welches bei der Verwendung von Techniken wie SQUID oder VSM auftreten würde. Unter der Voraussetzung, dass die Proben keinen senkrechten magnetischen Anisotropiebeitrag besitzen, kann die Sättigungsmagnetisierung selbst im Fall starker Grenzflächendurchmischung infolge einer großen Anzahl an Py/Ta-Grenzflächen und/oder Ionenbestrahlung mit hohen Fluenzen bestimmt werden. Ein weiterer wesentlicher Bestandteil dieser Arbeit ist die Konstruktion eines VNA-FMR-Spektrometers gewesen, welches vollautomatisiert ist, polare und azimutale Winkelabhängigkeiten messen kann und einen Magneten besitzt, der Proben, die Eisen beinhalten, sättigen kann. Von Grund auf beginnend umfasste dies zahlreiche Schritte wie z. B. die Entwicklung eines geeigneten koplanaren Wellenleiterdesigns sowie das Schreiben von Steuerungs-, Auswertungs- und Fitprogrammen. Mit steigender Fluenz und Zahl an Py/Ta-Grenzflächen ist eine Abnahme der Sättigungsmagnetisierung beobachtet worden. Im Fall der 10×Py-Proben findet diese bereits bei kleinen Fluenzen statt. Im Gegensatz dazu bleibt µ0MS der 1×Py- und 5×Py-Proben bis zu einer bestimmten Fluenz konstant, bevor sie sich dann umso schneller verringert. Die Bestrahlung mit Ne-Ionen verursacht eine Durchmischung und Verbreiterung der Grenzflächen. Infolgedessen erfahren die Py/Ta-Proben bei einer kritischen Fluenz, die von der Zahl der Grenzflächen abhängig ist, einen Phasenübergang von polykristallin zu amorph. Die Sättigungsmagnetisierung verschwindet ab einer Ta-Konzentration von etwa 10–15 Atom-% in den Py-Schichten. Die Proben besitzen eine kleine uniaxiale Anisotropie, die praktisch unbeeinflusst von der Fluenz ist, sich jedoch mit steigender Zahl an Py/Ta-Grenzflächen leicht verringert. Neben den statischen sind auch die dynamischen magnetischen Eigenschaften der Proben untersucht worden. Der Gilbert-Dämpfungsparameter α erhöht sich sowohl mit steigender Zahl an Py/Ta-Grenzflächen als auch mit höheren Fluenzen, wobei Erstere einen größeren Einfluss hat. Die inhomogene Linienverbreiterung ΔB0 nimmt ebenfalls mit steigender Zahl an Py/Ta-Grenzflächen zu, verringert sich jedoch bei größeren Fluenzen leicht.
152

Magneto-optical Kerr Effect Spectroscopy Study of Ferromagnetic Metal/Organic Heterostructures

Li, Wen 14 January 2011 (has links) (PDF)
Diese Dissertation stellt die erste Anwendung des magneto-optischen Kerr Effektes (MOKE) auf ferromagnetische Metall/Organische Heterostrukturen zur Aufklärung der optischen und chemischen Eigenschaften dar. Die MOKE-Untersuchungen wurden spektroskopisch in einem Energiebereich von 1.7 eV bis 5.5 eV durchgeführt. Heterostrukturen, wie sie hier untersucht werden, sind relevant für Anwendungen in der organischen Spintronik. Die Auswertung der Experimentellen Daten wird unterstützt durch numerische Simulationen eines Schichtmodells und ergänzende Untersuchung der strukturellen und magnetischen Eigenschaften unter Zuhilfenahme von AFM, TEM, SEM, STXM und SQUID-Magnetometrie. In der aktuellen Arbeit wurde Ni als Beispiel einer ferromagnetischen Schicht oberhalb oder unterhalb des organischen Films verwendet. Die organische Schicht besteht jeweils aus den diamagnetischen Molekülen Rubren, Pentacen und Fulleren, welche nur ein vernachlässigbares MOKE-Signal aufweisen. Zum Vergleich wurden das metallfreie Phtalocyanin H2Pc, welche ein nur eine bis zwei Größenordnungen schwächeres MOKE Signal als das genutzte Ni zeigen, betrachtet. Selbst Moleküle, welche kein intrinsisches MOKE-Signal zeigen, können über die optische Interferenz Einfluss auf das MOKE Signal von Ni nehmen. Daher kann die Dicke der organischen Schicht genutzt werden, um den Verlauf des MOKE Spektrum zu kontrollieren. Dies wird für Rubren und C60 gezeigt. Beim Vergleich des MOKE-Spektrums von Rubren/Ni- und Ni/Rubren-Doppelschichten war es möglich zu zeigen, dass die Metallablagerung an der Oberfläche einen Versiegelungseffekt hat, welcher die Oxidation der organischen Unterschicht verlangsamt. AFM und TEM Messungen zeigen, dass Ni die Morphologie der unteren Rubrenschicht annimmt. Die Proben, die mit einer geringen Wachstumsrate von Rubren hergestellt wurden, weisen bei einer nominellen Schichtdicke von 15 nm klar geformte Rubren-Inseln mit großen Abständen zwischen ihnen auf. In diesen Fällen zeigte die magnetische Hysteresemessung von MOKE bei Raumtemperatur eine unterschiedliche Gestalt in Abhängigkeit von der Photonenenergie. Die Hystereseschleifen wurden durch die Präsenz zweier magnetischer Phasen interpretiert. Die MOKE-Spektren dieser beiden Phasen wurden aus dem experimentellen Spektrum separiert. Die Gestalt des gemessenen Spektrums ändert sich mit der Stärke des angelegten Feldes aufgrund der unterschiedlichen Beiträge der zwei Phasen. An den ferromagnetischen Metall/organischen Schichten wurde TEM angewendet, um die Größe der Metallpartikel zu bestimmen, sowie STXM um die Orientierung der organischen Moleküle festzustellen. Die Schichtdicke, das Massenverhältnis sowie die Wechselwirkung zwischen Metall und organischen Material beeinflussen nachweislich das MOKE Signal.
153

Holographic imaging of cold atoms

Turner, Lincoln David Unknown Date (has links) (PDF)
This thesis presents a new optical imaging technique which measures the structure of objects without the use of lenses. Termed diffraction-contrast imaging (DCI), the method retrieves the object structure from a Fresnel diffraction pattern of the object, using a deconvolution algorithm. DCI is particularly adept at imaging highly transparent objects and this is demonstrated by retrieving the structure of an almost transparent cloud of laser-cooled atoms. Applied to transparent Bose-Einstein condensates, DCI should allow the non-destructive imaging of the condensate while requiring only the minimum possible apparatus of a light source and a detector. (For complete abstract open document)
154

Femtosecond magneto-optical four-wave mixing in Garnet films / Mélange à quatre ondes magnéto-optique femtoseconde dans les films de Grenat

Sanches Piaia, Monica 18 July 2014 (has links)
Un des objectifs du Femtomagnetisme est de contrôler l’aimantation des matériaux avec des impulsions laser femtoseconde. Il a été démontré qu’une réponse magnéto-optique (MO) cohérente a lieu avant la thermalisation des populations de spins dans une configuration pompe-sonde MOKE. Elle résulte du couplage cohérent spin-photon dû à l’interaction spin-orbite. Une description simplifiée de cet effet a été faite en tenant compte d’un système à huit niveaux couplés au champ laser. La cohérence MO est définie par le temps de déphasage dépendent du champ T2MO. Dans ce travail, il est montré que la réponse MO cohérente d’un grenat dopé au bismuth peut être mesurée directement avec différentes configurations de mélange à quatre ondes MO. L’importance de connaître la phase spectrale de l’impulsion pour obtenir T2MO a été étudié. Avec des impulsions de 10fs dans le proche infra-rouge, une mesure de T2MO donne (2.8+/-1)fs, c. à d., du même ordre de grandeur que le temps de déphasage des charges. / One of the goals of Femtomagnetism is to manipulate the magnetization of materials using femtosecond optical pulses. It has been shown in ferromagnetic films that a magneto-optical (MO) coherent response takes place before the thermalization of the spins populations in a pump and probe MOKE experiment. It results from the coherent spin-photon coupling mediated by the spin-orbit interaction. A simplified description of this effect has been made by considering an eight-level system coupled with the laser field. The MO coherence can be defined by the magnetic field dependent dephasing time T2MO. In the present work, it is shown that the coherent MO response of a bismuth-doped garnet can be directly measured in different degenerated MO four-wave mixing configurations. The importance of well-knowing the spectral phase of the pulse to measure T2MO was studied. Using 10fs near infra-red pulses, T2MO was shown to be (2.8+/-1)fs that is of the same order of the charges dephasing time.
155

Modèles cinétiques, de Kuramoto à Vlasov : bifurcations et analyse expérimentale d'un piège magnéto-optique / Kinetic models, from Kuramoto to Vlasov : bifurcations and experimental analysis of a magneto-optical trap

Métivier, David 22 September 2017 (has links)
Les systèmes en interaction à longue portée sont connus pour avoir des propriétés statistiques et dynamiques particulières. Pour décrire leur évolution dynamique, on utilise des équations cinétiques décrivant leur densité dans l'espace des phases. Ce manuscrit est divisé en deux parties indépendantes. La première traite de notre collaboration avec une équipe expérimentale sur un Piège Magnéto-Optique. Ce dispositif à grand nombre d'atomes présente des interactions coulombiennes effectives provenant de la rediffusion des photons. Nous avons proposé des tests expérimentaux pour mettre en évidence l'analogue d'une longueur de Debye, et son influence sur la réponse du système. Les expériences réalisées ne permettent pour l'instant pas de conclure de façon définitive. Dans la deuxième partie, nous avons analysé les modèles cinétiques de Vlasov et de Kuramoto. Pour étudier leur dynamique de dimension infinie, nous avons examiné les bifurcations autour des états stationnaires instables, l'objectif étant d'obtenir des équations réduites décrivant la dynamique de ces états. Nous avons réalisé des développements en variété instable sur cinq systèmes différents. Ces réductions sont parsemées de singularités, mais prédisent correctement la nature de la bifurcation, que nous avons testée numériquement. Nous avons conjecturé une réduction exacte (obtenue via la forme normale Triple Zero) autour des états inhomogènes de l'équation de Vlasov. Ces résultats génériques pourraient être pertinents dans un contexte astrophysique. Les autres résultats s'appliquent aux phénomènes de synchronisation du modèle de Kuramoto pour les oscillateurs avec inertie et/ou interactions retardées. / Long-range interacting systems are known to display particular statistical and dynamical properties.To describe their dynamical evolution, we can use kinetic equations describing their density in the phase space. This PhD thesis is divided into two distinct parts. The first part concerns our collaboration with an experimental team on a Magneto-Optical Trap. The physics of this widely-used device, operating with a large number of atoms, is supposed to display effective Coulomb interactions coming from photon rescattering. We have proposed experimental tests to highlight the analog of a Debye length, and its influence on the system response. The experimental realizations do not allow yet a definitive conclusion. In the second part, we analyzed the Vlasov and Kuramoto kinetic models. To study their infinite dimensional dynamics, we looked at bifurcations around unstable steady states. The goal was to obtain reduced equations describing the dynamical evolution. We performed unstable manifold expansions on five different kinetic systems. These reductions are in general not exact and plagued by singularities, yet they predict correctly the nature and scaling of the bifurcation, which we tested numerically. We conjectured an exact dimensional reduction (obtained using the Triple Zero normal form) around the inhomogeneous states of the Vlasov equation. These results are expected to be very generic and could be relevant in an astrophysical context. Other results apply to synchronization phenomena through the Kuramoto model for oscillators with inertia and/or delayed interactions.
156

Charakterisierung von dia-, para- und ferromagnetischen dünnen Schichten mittels magnetooptischer Kerr-Effekt-Spektroskopie

Fronk, Michael 13 September 2010 (has links)
Die polare magnetooptische Kerr-Effekt-Spektroskopie (MOKE) wird in dieser Arbeit zum ersten Mal zur Charakterisierung paramagnetischer Schichten eingesetzt. Die Schichten bestehen aus Phthalocyanin-Molekülen (H2Pc, VOPc, MnPc, CoPc und CuPc), die sich als Modellsystem zur Untersuchung des Einflusses des Molekülzentrums auf die elektronischen Zustände eignen. Die optischen Konstanten und die Dicken der Schichten werden mittels Ellipsometrie bestimmt. Mithilfe eines optischen Schichtmodells wird aus den Ellipsometrie- und MOKE-Daten die Voigt-Konstante, ein magnetooptischer Materialparameter, berechnet. Der Einfluss des Molekülzentrums auf die energetische Dispersion der Voigt-Konstante ist moderat. Vergleichsweise groß ist der Einfluss der Orientierung der Moleküle auf die Größe der Voigt-Konstante. Daher kann diese als Maß für den Aufstellwinkel des planaren CuPc herausgestellt werden. Darüber hinaus wird am Beispiel von CuPc gezeigt, dass sich die strukturelle Ordnung in molekularen Schichten mittels Reflexions-Anisotropie-Spektroskopie quantifizieren lässt. Die MOKE-Spektroskopie wird zusammmen mit MOKE-Magnetometrie auch zur Untersuchung von Eisen-Platin-Schichten mit Schichtdicken um 5 nm auf thermisch oxidiertem Silizium verwendet. Hier wird der Einfluss von eindiffundiertem Kupfer auf die magnetischen Eigenschaften Remanenz, Koerzitivität und magnetische Anisotropie der Schichten untersucht. Dabei wird neben der in Form einer Unterschicht bereitgestellten Kupfermenge die Temperatur variiert, bei der das Kupfer diffundiert. Die Magnetometrieuntersuchungen ergeben, dass Kupfer die magnetischen Eigenschaften der Eisen-Platin-Schichten verbessert, das Optimum des Kupfergehalts aber deutlich unter 20% liegt. Die optimale Mischtemperatur beträgt 600°C. Durch die Anwendung der MOKE-Spektroskopie wurde im Rahmen dieser Arbeit erstmals die Präsenz einer Feinstruktur der magnetooptischen Übergänge aus den 3d-Zuständen des Eisens entdeckt. Durch Vergleichsmessungen mit Schichten anderer Schichtdicke und auf anderen Substraten kann diese Feinstruktur mit mechanischen Verspannungen an der Grenzfläche zum Substrat in Verbindung gebracht werden.
157

Magneto-optical Kerr Effect Spectroscopy Study of Ferromagnetic Metal/Organic Heterostructures

Li, Wen 28 October 2010 (has links)
Diese Dissertation stellt die erste Anwendung des magneto-optischen Kerr Effektes (MOKE) auf ferromagnetische Metall/Organische Heterostrukturen zur Aufklärung der optischen und chemischen Eigenschaften dar. Die MOKE-Untersuchungen wurden spektroskopisch in einem Energiebereich von 1.7 eV bis 5.5 eV durchgeführt. Heterostrukturen, wie sie hier untersucht werden, sind relevant für Anwendungen in der organischen Spintronik. Die Auswertung der Experimentellen Daten wird unterstützt durch numerische Simulationen eines Schichtmodells und ergänzende Untersuchung der strukturellen und magnetischen Eigenschaften unter Zuhilfenahme von AFM, TEM, SEM, STXM und SQUID-Magnetometrie. In der aktuellen Arbeit wurde Ni als Beispiel einer ferromagnetischen Schicht oberhalb oder unterhalb des organischen Films verwendet. Die organische Schicht besteht jeweils aus den diamagnetischen Molekülen Rubren, Pentacen und Fulleren, welche nur ein vernachlässigbares MOKE-Signal aufweisen. Zum Vergleich wurden das metallfreie Phtalocyanin H2Pc, welche ein nur eine bis zwei Größenordnungen schwächeres MOKE Signal als das genutzte Ni zeigen, betrachtet. Selbst Moleküle, welche kein intrinsisches MOKE-Signal zeigen, können über die optische Interferenz Einfluss auf das MOKE Signal von Ni nehmen. Daher kann die Dicke der organischen Schicht genutzt werden, um den Verlauf des MOKE Spektrum zu kontrollieren. Dies wird für Rubren und C60 gezeigt. Beim Vergleich des MOKE-Spektrums von Rubren/Ni- und Ni/Rubren-Doppelschichten war es möglich zu zeigen, dass die Metallablagerung an der Oberfläche einen Versiegelungseffekt hat, welcher die Oxidation der organischen Unterschicht verlangsamt. AFM und TEM Messungen zeigen, dass Ni die Morphologie der unteren Rubrenschicht annimmt. Die Proben, die mit einer geringen Wachstumsrate von Rubren hergestellt wurden, weisen bei einer nominellen Schichtdicke von 15 nm klar geformte Rubren-Inseln mit großen Abständen zwischen ihnen auf. In diesen Fällen zeigte die magnetische Hysteresemessung von MOKE bei Raumtemperatur eine unterschiedliche Gestalt in Abhängigkeit von der Photonenenergie. Die Hystereseschleifen wurden durch die Präsenz zweier magnetischer Phasen interpretiert. Die MOKE-Spektren dieser beiden Phasen wurden aus dem experimentellen Spektrum separiert. Die Gestalt des gemessenen Spektrums ändert sich mit der Stärke des angelegten Feldes aufgrund der unterschiedlichen Beiträge der zwei Phasen. An den ferromagnetischen Metall/organischen Schichten wurde TEM angewendet, um die Größe der Metallpartikel zu bestimmen, sowie STXM um die Orientierung der organischen Moleküle festzustellen. Die Schichtdicke, das Massenverhältnis sowie die Wechselwirkung zwischen Metall und organischen Material beeinflussen nachweislich das MOKE Signal.
158

Magnetostatics and Dynamics of Ion Irradiated NiFe/Ta Multilayer Films Studied by Vector Network Analyzer Ferromagnetic Resonance

Markó, Daniel 25 November 2010 (has links)
In the present work, the implications of ion irradiation on the magnetostatic and dynamic properties of soft magnetic Py/Ta (Py = Permalloy: Ni80Fe20) single and multilayer films have been investigated with the main objective of finding a way to determine their saturation magnetization. Both polar magneto-optical Kerr effect (MOKE) and vector network analyzer ferromagnetic resonance (VNA-FMR) measurements have proven to be suitable methods to determine µ0MS, circumventing the problem of the unknown effective magnetic volume that causes conventional techniques such as SQUID or VSM to fail. Provided there is no perpendicular anisotropy contribution in the samples, the saturation magnetization can be determined even in the case of strong interfacial mixing due to an inherently high number of Py/Ta interfaces and/or ion irradiation with high fluences. Another integral part of this work has been to construct a VNA-FMR spectrometer capable of performing both azimuthal and polar angle-dependent measurements using a magnet strong enough to saturate samples containing iron. Starting from scratch, this comprised numerous steps such as developing a suitable coplanar waveguide design, and writing the control, evaluation, and fitting software. With both increasing ion fluence and number of Py/Ta interfaces, a decrease of saturation magnetization has been observed. In the case of the 10×Py samples, an immediate decrease of µ0MS already sets in at small ion fluences. However, for the 1×Py and 5×Py samples, the saturation magnetization remains constant up to a certain ion fluence, but then starts to rapidly decrease. Ne ion irradiation causes a mixing and broadening of the interfaces. Thus, the Py/Ta stacks undergo a transition from being polycrystalline to amorphous at a critical fluence depending on the number of interfaces. The saturation magnetization is found to vanish at a Ta concentration of about 10–15 at.% in the Py layers. The samples possess a small uniaxial anisotropy, which remains virtually unaffected by the ion fluence, but slightly reduces with an increasing number of Py/Ta interfaces. In addition to magnetostatics, the dynamic properties of the samples have been investigated as well. The Gilbert damping parameter α increases with both increasing number of Py/Ta interfaces and higher ion fluences, with the former having a stronger influence. The inhomogeneous linewidth broadening ΔB0 increases as well with increasing number of Py/Ta interfaces, but slightly decreases for higher ion fluences. / In dieser Dissertation ist der Einfluss von Ionenbestrahlung auf die magnetostatischen und dynamischen Eigenschaften von weichmagnetischen Py/Ta-Einzel- und Multilagen (Py = Permalloy: Ni80Fe20) untersucht worden, wobei das Hauptziel gewesen ist, eine Methode zur Bestimmung der Sättigungsmagnetisierung zu finden. Sowohl polare magneto-optische Kerr-Effektmessungen (MOKE) als auch ferromagnetische Resonanzmessungen mittels eines Vektornetzwerkanalysators (VNA-FMR) haben sich als geeignet erwiesen, um µ0MS zu bestimmen, wobei das Problem des unbekannten effektiven magnetischen Volumens umgangen wird, welches bei der Verwendung von Techniken wie SQUID oder VSM auftreten würde. Unter der Voraussetzung, dass die Proben keinen senkrechten magnetischen Anisotropiebeitrag besitzen, kann die Sättigungsmagnetisierung selbst im Fall starker Grenzflächendurchmischung infolge einer großen Anzahl an Py/Ta-Grenzflächen und/oder Ionenbestrahlung mit hohen Fluenzen bestimmt werden. Ein weiterer wesentlicher Bestandteil dieser Arbeit ist die Konstruktion eines VNA-FMR-Spektrometers gewesen, welches vollautomatisiert ist, polare und azimutale Winkelabhängigkeiten messen kann und einen Magneten besitzt, der Proben, die Eisen beinhalten, sättigen kann. Von Grund auf beginnend umfasste dies zahlreiche Schritte wie z. B. die Entwicklung eines geeigneten koplanaren Wellenleiterdesigns sowie das Schreiben von Steuerungs-, Auswertungs- und Fitprogrammen. Mit steigender Fluenz und Zahl an Py/Ta-Grenzflächen ist eine Abnahme der Sättigungsmagnetisierung beobachtet worden. Im Fall der 10×Py-Proben findet diese bereits bei kleinen Fluenzen statt. Im Gegensatz dazu bleibt µ0MS der 1×Py- und 5×Py-Proben bis zu einer bestimmten Fluenz konstant, bevor sie sich dann umso schneller verringert. Die Bestrahlung mit Ne-Ionen verursacht eine Durchmischung und Verbreiterung der Grenzflächen. Infolgedessen erfahren die Py/Ta-Proben bei einer kritischen Fluenz, die von der Zahl der Grenzflächen abhängig ist, einen Phasenübergang von polykristallin zu amorph. Die Sättigungsmagnetisierung verschwindet ab einer Ta-Konzentration von etwa 10–15 Atom-% in den Py-Schichten. Die Proben besitzen eine kleine uniaxiale Anisotropie, die praktisch unbeeinflusst von der Fluenz ist, sich jedoch mit steigender Zahl an Py/Ta-Grenzflächen leicht verringert. Neben den statischen sind auch die dynamischen magnetischen Eigenschaften der Proben untersucht worden. Der Gilbert-Dämpfungsparameter α erhöht sich sowohl mit steigender Zahl an Py/Ta-Grenzflächen als auch mit höheren Fluenzen, wobei Erstere einen größeren Einfluss hat. Die inhomogene Linienverbreiterung ΔB0 nimmt ebenfalls mit steigender Zahl an Py/Ta-Grenzflächen zu, verringert sich jedoch bei größeren Fluenzen leicht.
159

Determining the damping coefficient in a magneto-optical trap

Pandey, Krishna Prasad 01 August 2023 (has links)
No description available.
160

Constructing and Commissioning HELIOS – A High Harmonic Generation Source for Pump-Probe Measurements with sub 50 fs Temporal Resolution : The Development of Experimental Equipment for Extreme Ultraviolet Spectroscopy

Terschlüsen, Joachim A. January 2016 (has links)
This thesis presents HELIOS, an in-house laboratory for time-resolved pump-probe spectroscopy with extreme-ultraviolet (XUV) probe radiation. A wide span of pump wavelengths can be generated using commercial laser equipment while XUV probe radiation is generated via a high harmonic generation process in a noble gas delivering probe photons with energies between 20 eV and 72 eV. The XUV beam path features a time-preserving monochromator and was constructed and built in-house. HELIOS features an overall time resolution of about 50 fs when using 800 nm pump and 41 eV probe photons. An energy resolution of 110 meV at 41 eV photon energy can be achieved. HELIOS features two beamlines. One µ-focus beamline with an XUV focal size of about 20 µm can be used with experiments that require such a small XUV focal size as well as with different end stations. The other beamline features a semi-permanently mounted end station for angle-resolved photoelectron spectroscopy under ultra-high vacuum conditions. Experiments demonstrating the usability of HELIOS and the two beamlines are presented. A pump-probe measurement on graphene demonstrates the capability of determining a large part of the k-space in only one measurement due to the use of an ARTOF angle-resolved time-of-flight electron spectrometer. A non-angle-resolved pump-probe measurement on the conducting polymer PCPDTBT demonstrates the high signal-to-noise ratio achievable at this beamline in non-angle-resolved photoelectron-spectroscopy pump-probe measurements. The usability of the µ-focus beamline is demonstrated with time-resolved measurements on magnetic samples employing an in-house-designed spectrometer. These experiments allow the retrieval of element-specific information on the magnetization within a sample employing the transversal magneto-optical Kerr effect (T-MOKE). Additionally, a Fourier transform spectrometer for the XUV is presented, the concept was tested at a synchrotron and it was used to determine the longitudinal coherence of the XUV radiation at HELIOS.