311 |
Desenvolvimento de uma metodologia computacional para calculos em dosimetria internaYORIYAZ, HELIO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:03Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:55Z (GMT). No. of bitstreams: 1
06878.pdf: 8623929 bytes, checksum: 9403b721e2a38e59f0a65c626040f7f0 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
312 |
Desenvolvimento de método para separação química de gálio-67 pela técnica de difusão térmica / Development of method to chemical separation of gallium-67 by thermal diffusion techniqueMARTINS, PATRICIA de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:17Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:06Z (GMT). No. of bitstreams: 0 / Radioisótopos de gálio são estudados e avaliados para aplicações médicas desde 1949. Nos últimos 50 anos 67Ga tem sido amplamente utilizado no diagnóstico de diversas patologias, incluindo lesões inflamatórias crônicas e agudas, bacterianas ou estéreis e diversos tipos de tumores. No Brasil 30% das clinicas que prestam serviços de Medicina Nuclear utilizam o Citrato de 67Ga com uma demanda de distribuição no IPEN-CNEN/SP de 37 GBq (1 Ci) por semana. O 67Ga apresenta meia-vida física de 3,26 dias (78 horas) e decai 100% por captura eletrônica para o 67Zn estável. Seu decaimento inclui a emissão de raios γ com energias de 93,3 keV (37%), 184,6 keV (20,4%), 300,2 keV (16,6%) e 888 keV (26%). No IPEN o 67Ga era produzido a partir da reação 68Zn(p, 2n)67Ga. Após a irradiação, o alvo era totalmente dissolvido em HCl concentrado e a solução percolada em resina catiônica DOWEX 50W-X8, 200-400 mesh, condicionada em HCl 10 mol L-1. Zinco, níquel e cobre eram eluídos em HCl 10 mol L-1 e o 67Ga em HCl 3,5 mol L-1. O produto final era obtido na forma de citrato de 67Ga. Este trabalho apresenta um método inédito, rápido, direto e eficiente de separação química e obtenção de 67GaCl3 a partir da difusão térmica (aquecimento do alvo) aliada à extração em ácido acético concentrado. A purificação foi realizada por cromatografia de troca iônica. Realizou-se a eletrodeposição do zinco natural em placas de cobre niquelado como substrato e os depósitos de zinco obtidos foram aderentes ao substrato, levemente brilhantes e uniformes. Os alvos foram irradiados com prótons de 26 MeV e corrente integrada de 10 μA.h. Após a irradiação, os alvos foram aquecidos a 300 °C por 2 horas e colocados em contato com ácido acético concentrado por 1 hora. O rendimento médio de extração de 67Ga obtido foi de (72±10)%. Esta solução foi evaporada e o resíduo foi retomado em NH4OH 0,5 mol L-1. O 67Ga foi purificado em resina catiônica Dowex 50WX8 em meio de NH4OH. A recuperação obtida foi de (98 ± 2) %, de 67Ga. O eluido foi evaporado e retomado em HCl 0,1 mol L-1. A pureza química foi verificada por ICP-OES encontrando-se (2 ± 1) μg mL -1 de zinco. As concentrações de ferro, cobre e níquel foram inferiores ao limite de detecção do método e aos limites de utilização de 67Ga. A pureza radionuclídica foi verificada por espectroscopia-γ utilizando um detector de germânio Hiper-Puro encontrando-se valor superior a (99,9%). Este método inédito permite a obtenção de 67Ga com alta pureza química, radioquímica e radionuclídica em condições de processamento menos agressivas e corrosivas que o método comumente utilizado. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
313 |
Desenvolvimento de um radiofármaco para marcação com Tc-99m para a identificação de infecção utilizando um peptídeo catiônico sintético / Development of a Tc-99m labeling radiopharmaceutical for infection identification using a synthetic cationic peptideDIAS, LUIS A.P. 03 February 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-02-03T12:08:21Z
No. of bitstreams: 0 / Made available in DSpace on 2016-02-03T12:08:21Z (GMT). No. of bitstreams: 0 / O crescimento anual no número de procedimentos realizados em Medicina Nuclear se deve em primeiro lugar à vantagem de não serem invasivos. Cerca de 80% dos diagnósticos realizados em Medicina Nuclear utilizam radiofármacos preparados com tecnécio-99m devido a suas características físicas ideais, disponibilidade e baixo custo. Dentre os radiofármacos utilizados para identificar processos de infecção e inflamação estão os leucócitos marcados com tecnécio-99m, considerado o padrão ouro e o citrato de gálio (67 Ga), atualmente comercializado no Brasi. Os leucócitos marcados possuem a desvantagem da técnica laboriosa de marcação nem sempre disponível nos centros de Medicina Nuclear, enquanto o citrato de gálio (67 Ga) não é específico e possui energias desfavoráveis para a dosimetria do paciente e para a aquisição de imagens. Neste cenário, novas moléculas para diagnóstico de focos de infecção têm sido pesquisadas, particularmente envolvendo biomoléculas, como os peptídeos antimicrobianos. Nesta categoria, a Ubiquicidina na forma de um fragmento sintético (UBI 29-41) despertou o interesse de pesquisadores que estudaram a marcação com tecnécio-99m utilizando métodos direto e indireto. Um reagente liofilizado de UBI 29-41descrito na literatura demonstrou eficácia no diagnóstico de focos de infecção utilizando-se imagens cintilográficas, porém o produto não está disponível no Brasil. O objetivo deste trabalho foi estudar a marcação do fragmento de UBI 29-41 com tecnécio-99m por método direto e avaliar a utilização de soluções tampão no procedimento de marcação, de modo a flexibilizar o volume da solução de pertecnetato de sódio a ser utilizado, o que constitui aspecto de ineditismo deste trabalho. O fragmento foi radiomarcado com diferentes volumes de soluções tampão alcalinas (carbonato e fosfato) e a utilização dos tampões em substituição à solução de hidróxido de sódio possibilitou realizar a marcação com diferentes volumes da solução de pertecnetato de sódio, sem comprometimento do rendimento de marcação. Uma formulação liofilizada foi avaliada, demonstrando estabilidade por período de 12 meses, viabilizando a produção rotineira do agente de marcação. Os estudos de biodistribuição das preparações efetuadas com os diferentes tampões demonstraram que os complexos formados apresentam características gerais de biodistribuição semelhantes ao composto padrão descrito na literatura, incluindo rápido clareamento sanguíneo e alta captação renal, condizente com a eliminação do produto por esta via. Entretanto, as preparações estudadas apresentaram captação hepática maior e captação renal menor que o composto padrão. As preparações estudadas captaram no foco de infecção provocado por S.aureus e demonstraram potencial para aplicação clínica no diagnóstico em Medicina Nuclear. Como pré-requisito para a realização de estudos clínicos de um novo composto foi realizado estudo de cito e genotoxicidade, cujos resultados demonstraram a segurança das preparações estudadas. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
314 |
Estudo de uma câmara de ionização tipo poço através de simulação Monte Carlo / Study of a well-type ionization chamber by Monte Carlo simulationMairon Marques dos Santos 25 September 2009 (has links)
O uso de simulação Monte Carlo do transporte de radiação na matéria tem sido cada vez mais empregado nas áreas de física radiológica e dosimétrica. Em Medicina Nuclear é possível usar diversos códigos de simulação como ferramenta para estudar diferentes características de resposta de calibradores de dose. O código de simulação Monte Carlo PENELOPE (Penetration and ENErgy LOss of Positron and Electrons) possui um algoritmo misto do transporte de radiação, condensando eventos de interação, conforme os parâmetros de entrada estabelecidos. Neste trabalho, o código de simulação PENELOPE foi usado para estudar a resposta de uma câmara de ionização em função de diversos parâmetros que influenciam suas características de resposta. Neste trabalho os parâmetros de resposta de uma câmara de ionização tipo poço foram estudados através de simulação Monte Carlo, comparando-se os resultados obtidos com dados experimentais. A eficiência da câmara foi testada através de simulação e mostrou-se condizente com os valores previstos através de cálculos. Com relação à atividade, a resposta se mostrou linear para todos os nuclídeos estudados, sendo possível se obter a sensibilidade relativa da câmara através de simulação e de medidas experimentais. A resposta da câmara em função a energia, obtida através de simulação, também representou bem os valores experimentais, sendo possível extendê-los para energias mais altas e mais baixas que os valores das medidas experimentais. Estudos do volume de radiofármaco e da posição da fonte no poço da câmara obtidos através de simulação apresentaram comportamento esperado de acordo com a literatura. O código PENELOPE foi validado para o estudo desta câmara de ionização, permitindo que parâmetros geométricos e de materiais sejam estudados sem os custos e as dificudades dos arranjos experimentais. / The use of Monte Carlo simulation to the radiation transport in matter has been widly applied in the radiological and dosimetric areas. In Nuclear Medicine it is possible to use a variety of simulation codes as tools to study different response characteristics of dose calibrators used to measure radionuclides activities. The PENELOPE (Penetration and ENErgy LOss of Positron and Electrons) Monte Carlo simulation code has a mixed algorithm for the transport of radiation, which condenses the interaction events according to the input parameters. In this work, the PENELOPE code of simulation was used to study the response of an ionization chamber as function of parameters influencing its response. The chamber efficiency was tested by simulation and it showed a good agreement with calculated results. To the activity, its response showed a linear behavior for all studied nuclides, allowing one to obtain its sensitivity by simulation and measurements. The response of the chamber as a function of the energy obtained by simulation also showed a good agreement with the measurements, allowing one to extrapolate it to energies below and above the measured ones. The analysis with the volume of radiopharmaceuticals and position of the sourse in the chamber well obtained by simulation showed the expected behavior compared to the ones in literature. PENELOPE was validated to study this ionization chamber, so allow one to perform geometric and material parameters studies without experimental costs and difficulties.
|
315 |
Atividades de radioisótopos administradas em Medicina Nuclear e proposta de nível de referência em diagnóstico (DRL) para o Brasil / Administered radioisotope activities in Nuclear Medicine and a proposal of diagnostic reference level (DRL) to BrasilLuis Felipe Emanuel Faleiros Braga 14 October 2016 (has links)
Estima-se que o número de exames diagnósticos em Medicina Nuclear cresça a uma taxa de 5% ao ano, ocasionando aumento das exposições de pacientes, familiares e meio ambiente às radiações ionizantes. O intuito dos guias de referência em exames diagnósticos (DRL) é a padronização das técnicas e a diminuição das exposições ao mínimo possível e estritamente necessárias para a realização do exame médico, todavia, a área de Medicina Nuclear brasileira não possui este tipo de guia, favorecendo o descontrole das exposições e incremento de riscos associados. O principal objetivo deste estudo foi a elaboração de um DRL para a área de Medicina Nuclear com base nos tipos de exames, atividades administradas, técnicas adotadas e parque de equipamentos disponíveis no país. Formulários foram enviados para todos os Serviços de Medicina Nuclear do Brasil - SMNs (~430) visando obter essas informações, bem como os tipos de ajustes das atividades de acordo com a idade e o peso corpóreo dos pacientes. Os dados foram analisados e como proposta de DRL, considerou-se o valor do percentil 75 (P75) da atividade máxima administrada em cada exame. Um total de 107 SMNs, representando 14 estados brasileiros e o Distrito Federal, responderam ao questionário. Dos 64 diferentes procedimentos diagnósticos analisados, as cintilografias óssea, renal e paratireoide são disponibilizadas em mais de 85% de todos os SMNs analisados. As atividades administradas para um mesmo tipo de exame apresentaram uma alta taxa de dispersão, alcançando diferenças superiores a 20 vezes entre o menor e maior valor praticado. Exames diagnósticos envolvendo os radioisótopos 67Ga, 201Tl e 131I foram observados como os geradores de maior dose de radiação aos pacientes. O ajuste das atividades para pacientes pediátricos tem levado em consideração a regra de Webster, regra de três simples e ajustes empíricos de acordo com o peso corpóreo dos pacientes. Com a aplicação dos valores de atividade propostos como DRL na rotina clínica, pode-se alcançar uma redução mínima de 15%, máxima de 95% e média de 50% em relação às atividades atualmente aplicadas. Ao todo, foram encontrados 189 equipamentos de imagem em funcionamento, sendo principalmente de quatro fabricantes diferentes (Elscint, GE, Philips e Siemens). A variabilidade das atividades administradas para um mesmo tipo de exame, respeitando as diferenças tecnológicas, pode refletir a falta de controle das exposições à radiação e a inexistência de um guia de referência nacional para a área de Medicina Nuclear, assim como também exemplificar a diversidade de protocolos de imagem praticados no país. A adoção de um DRL para a área de Medicina Nuclear poderia contribuir consideravelmente para o controle das exposições e padronização da técnica, ofertando à população exames de alta tecnologia e de riscos controlados / It has been estimated that the number of diagnostic procedures in Nuclear Medicine has shown an annual growth rate of 5%, and consequently increasing the ionizing radiation exposition of patients, family and environment. The aim of diagnostic reference levels (DRL) is the standardization of techniques and decrease expositions to as low as possible and just compatible with the diagnostic exam under study. However, Brazilian Nuclear Medicine does not have those references, causing a decontrol of expositions and increasing the associated risks. The main objective of this study was the DRL development to Nuclear Medicine on the basis of diagnostic procedures, administered activities, adopted techniques, and the available equipments in the country. Forms were sent to all the Brazilian Nuclear Medicine Services -NMS (~430) aiming to obtain those information, as well as the rules applied to adjust the administered activities according to patient\'s age and body mass. All data were analyzed, and the percentile 75 (P75) of the maximum activity applied in each diagnostic exam was considered as the DRL. A total of 107 NMS have answered the form, representing 14 Brazilian states and Federal District. From the 64 diagnostic procedures studied, bone, kidney and parathyroid scintigraphy were found to be used in more than 85% of all the NMS analyzed. There was a large disparity among the activities administered, when applying the same procedure, reaching, in some cases, more than 20 times between the lowest and highest. Diagnostic exams based on 67Ga, 201Tl, and 131I radioisotopes proved to be de major exams administering radiation doses to patients. The activities adjustment to pediatric patients has used different rules, including Webster rule, rule of three and empirical adjustments according to the patient\'s body weight. On introducing the DRL activity values into clinical routine, the minimum reduction in radiation doses received by patients was about 15%, the maximum was 95%, and the average was 50% compared with the previously reported administered activities. There were found 189 image equipments working, with mainly 4 different brands (Elscint, GE, Philips e Siemens). The variability in the administered activities to the same diagnostic procedure, respecting the existing differences in technology, may reflect the lack of radiation exposition control and the non-existence of a national reference guide to Nuclear Medicine, as well as exemplify the variability in the image protocols practiced in the country. The establishment of DRL to a Nuclear Medicine could considerably contribute toward the control and reduction of radiation exposure, thereby offering to the public high-technology exams with controlled risks
|
316 |
DOC BASE NUCLEAR 1.01: software de gestão de documentos em Serviços de Medicina Nuclear Juiz de ForaBarroso, Adelanir Antonio 10 April 2017 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-06-19T12:16:50Z
No. of bitstreams: 1
adelanirantoniobarroso.pdf: 1550547 bytes, checksum: c29a77a5cddabe41dae80005aea02776 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-06-29T12:21:34Z (GMT) No. of bitstreams: 1
adelanirantoniobarroso.pdf: 1550547 bytes, checksum: c29a77a5cddabe41dae80005aea02776 (MD5) / Made available in DSpace on 2017-06-29T12:21:34Z (GMT). No. of bitstreams: 1
adelanirantoniobarroso.pdf: 1550547 bytes, checksum: c29a77a5cddabe41dae80005aea02776 (MD5)
Previous issue date: 2017-04-10 / O software de gestão de documentos em Serviços de Medicina Nuclear (SMN), denominado DOC BASE NUCLEAR 1.01, funciona via local e por acesso remoto (via web), com o objetivo principal de arquivamento eletrônico e controle da documentação exigida pelos órgãos reguladores brasileiros, com ênfase especial para Agência Nacional de Vigilância Sanitária (ANVISA), Comissão Nacional de
Energia Nuclear (CNEN) e Ministério do Trabalho e Previdência Social (MTPS). O software possibilita a criação de checklist da base documental exigida, com definições de origem e validade dos documentos. O processo inicial teve origem na análise de pastas físicas que foram criadas e indexadas, com documentos impressos que serviram de base para orientar o modelo do software, desenvolvido
em linguagem Visual Basic, plataforma .NET, com banco de dados SQL SERVER, além da linguagem ASP NET. O programa foi concebido de forma a permitir a inclusão de cópias digitalizadas da legislação específica, além de documentos adicionais e suas especificações, com orientações e alertas para a permanente manutenção da base documental em conformidade com a legislação vigente. Na
fase tardia do projeto as aplicações foram expandidas permitindo a inclusão de documentos advindos de diferentes origens, incluindo aqueles internos do SMN facilitando a centralização, o arquivamento eletrônico e a controladoria dos mesmos. É possível, ainda, elaborar uma lista digital de exigências e incluir novos documentos, respeitando seus algoritmos e pré-requisitos para obtenção dos mesmos. A caixa de busca por denominações facilita a localização e o acesso aos documentos que, selecionados, são agrupados em local específico, sob o nome genérico de “carrinho de documentos” e, ao término da seleção, são finalizados (fechados) com a criação de pasta personalizada para o uso a que se destine. O
software foi submetido a teste operacional em SMN, com boa resposta aos objetivos propostos, fácil execução e boa interação com usuário. / The present product DOC BASE NUCLEAR 1.01 is a document management software in Nuclear Medicine Services (SMN), which works via local and remote access (web) with the main objective of electronically filing and controlling the documentation required by the Brazilian regulatory agencies, with special emphasis on the National Agency of Sanitary Surveillance (ANVISA), the National Nuclear
Energy Commission (CNEN) and the Ministry of Labor and Social Security (MTPS). The product enables the creation of a checklist of the required documentary base, with definitions of origin and validity of the documents. This initial process originated from the analysis of physical folders that were created and indexed, with printed documents that served as a basis to guide the design of the software, developed in
Visual Basic language .NET platform (DOT NET), with SQL SERVER database and ASP NET language.The software has been created to allow the inclusion of digitised copies of specific legislation, as well as additional documents and their specifications, with guidelines and alerts/notifications for the permanent maintenance of the documentary base, in accordance with current legislation. At a later stage of the project, the possible applications of the software were expanded and allowed for the inclusion of different sources, such as internal documents from SMN, facilitating their centralisation, electronic archiving and control. The software generates a digital list of requirements and the inclusion of new documents, maintaining the algorithms of the requirements and prerequisites for obtaining them. One can find a search box for denominations in order to locate and access to documents that are selected as a
group under the generic name of “documents cart" and that, at the end of the selection, are finalized (closed) with the new custom folder for your intended use. The software has been tested by Nuclear Medicine Services, with a good responseregarding its objectives, usability and good user interaction.
|
317 |
Det korta mötet med barn i vården : En litteraturstudie om upplevelser hos sjuksköterskor / The short meeting with children in healthcare : A literature review on nurses experiencesAhlgren, Johanna January 2018 (has links)
Inledning: Den största anledningen till att barn kommer i kontakt med sjukvården är på grund av misstänkt fraktur, vilket innebär att röntgensjuksköterskor ofta möter barn i det dagliga arbetet på röntgenavdelningen. Trots det är dessa sällan utbildade i bemötande av barn, eller inom pediatrisk bildtagning. Vuxna som inte är vana vid att hantera barn kan känna viss tveksamhet eller rädsla inför att vårda ett barn. För att kunna förbättra mötet med barn är det viktigt att veta vilka känslor sjukvårdpersonal känner i mötet, och varför. Syfte: att beskriva vilka upplevelser sjukvårdpersonal känner i mötet med barn. Metod: Studien utfördes som en litteraturöversikt med 10 artiklar som granskades med en induktiv kvalitativ innehållsanalys. De 10 artiklarna var av kvalitativ ansats och intervjuade sjukvårdspersonal som bestod av ambulanspersonal, akutsjuksköterskor, allmänsjuksköterskor och radioterapeuter. Resultat: Fyra kategorier; bemötande, hanterbarhet, tiden har betydelse och föräldrar. Dessa beskriver i vilka situationer sjukvårdspersonal upplever både negativa och positiva känslor i mötet med barn. Slutsats: att identifiera vilka känslor som uppstår är grunden för fortsatta studier för att förbättra arbetsmiljön för såväl röntgensjuksköterskor som övrig sjukvårdspersonal.
|
318 |
Magnetresonanstomografi vid diagnostisering av misstänkt scaphoideumfraktur : - fördelar med den tidiga undersökningenBerggren, Ida, Stange, Josefina January 2018 (has links)
Inledning: Det är omkring 30 % av alla scaphoideumfrakturer som i dag inte går att identifiera med den första konventionella radiologiska undersökningen. Vid misstänkt fraktur på scaphoideum börjar man med en klinisk undersökning av patienten, och går sen vidare med en konventionell röntgenundersökning för att kunna utesluta eller bekräfta eventuell fraktur.Dock är det klargjort att alla skadorna inte syns initialt på röntgenbilderna, vilket leder till att det blir svårt att ställa en säker diagnos av dessa patienter. MR-undersökningar kan vid behov användas för att kunna fastställa en diagnos. Syfte: Syftet med studien var att sammanställa kunskap kring vilka fördelar en tidig magnetresonanstomografiundersökning har vid en misstänkt scaphoideumfraktur. Metod: Studien genomfördes som en allmän litteraturstudie. Tio artiklarkvalitetsgranskades, analyserades och resultatet presenterades i kategorier. Resultat: Resultatet visade att de scaphoideumfrakturer som de konventionella röntgenbilderna inte kunde identifiera gick att identifiera med en tidig MR-undersökning. Det gick även att identifiera mjukdelsskador vilket medverkade till att patienten fick behandling utifrån diagnos. Dessutom visade resultatet att totalkostnaderna inte skiljer sig åt mellan konventionellt röntgenundersökta patienter gentemot MR-undersökta patienter. Det anses vara viktigt att radiologen har goda erfarenheter av att bedöma MR-bilder.Konklusion:Tidig MR-undersökning av en misstänkt scaphoideumfraktur påverkar hur patientens behandling utformas. Med en tidig undersökning kan patienter få en definitiv diagnos och därmed inte behöva vänta tills det är dags för en efterkontroll. Vidare forskning anses nödvändigt inom området där det undersöks hur patienter i Sverige påverkas av undersökningsförändringen med en tidig MR-undersökning, vid misstänkt scaphoideumfraktur.
|
319 |
Röntgensjuksköterskans upplevelse av att arbeta med externa granskare under jourtid : En kvalitativ intervjustudie / The radiographers experience of working with teleradiology during night shifts : A qualitative interview studyBaltsén, Cecilia, Wiberg, Elin January 2017 (has links)
Titel: Röntgensjuksköterskans upplevelse av att arbeta med externa granskare under jourtid Syfte: Att undersöka hur röntgensjuksköterskan upplever arbetet med externa granskare under jourtid. Material och metod: Sex stycken röntgensjuksköterskor från två olika sjukhus i mellansverige intervjuades under perioden januari till mars 2017. Inklusionskriterierna för studien var minst två års erfarenhet av yrket samt minst ett års erfarenhet av att arbeta med externa granskare under jourtid. Tillstånd från verksamhetschefer och samtycke från informanterna erhölls innan studien startade. Data samlades in genom en kvalitativ metod med semistrukturerade intervjuer bestående av öppna frågor. Den insamlade datan analyserades med kvalitativ innehållsanalys enligt Graneheim & Lundman. Intervjuerna transkriberades och lästes igenom flera gånger. Därefter identifierades meningsbärande enheter och dessa kondenserades till koder. Genom koderna kunde kategorier och subkategorier identifieras. Resultat: I resultatet framkom fyra kategorier; Teleradiologi – tekniska aspekter, externa granskare jämfört med radiolog på plats, kommunikation och röntgensjuksköterskans kompetenser och egenskaper med tillhörande subkategorier. Konklusion: Informanterna upplever att det tar längre tid att kommunicera med externa granskare (EG) i jämförelse med att ha en radiolog på plats som kan ge svar direkt när röntgensjuksköterskan (RSS) är i behov av vägledning och snabba svar. I kommunikationen upplevs det också finnas språkbarriärer samt bristande kunskap, speciellt hos de sekreterare som tar emot samtal hos EG. Detta leder till frustration och blir ofta ett hinder i akuta situationer då RSS vill prata med en radiolog direkt. Under jourtid upplever RSS att denne får ta ett ökat ansvar samtidigt som förmågan att ta egna initiativ och beslut måste finnas. RSS upplever ingen förändring av bildkvalitén på de bilder som skickas i arbetet med EG. Informanterna upplevde i helhet att arbetet med EG fungerar bra och tillfredsställande under förutsättningarna att tekniken fungerar som den ska samtidigt som arbetsflödet inte ökar för mycket.
|
320 |
Kan ultraljud ersätta konventionell lungröntgen för att diagnostisera barn med misstänkt pneumoni? : En allmän litteraturöversikt / Can ultrasound replace conventional chest x-ray to diagnose children with suspected pneumonia? : A general literature reviewSalmela, Marika, Uggla, Olivia January 2017 (has links)
Pneumoni är globalt sett den största orsaken till sjukdom och mortalitet bland barn under fem år, med 920 000 dödsfall under 2015. I Sverige är pneumoni den största orsaken till sjukdom bland barn, med ett hastigt insjuknande med allmänpåverkan, feber, frossa och andningsproblem. I dagsläget ställs diagnos med hjälp av kliniska symtom och lungröntgen, vilket utsätter barnen för joniserande strålning. Med ultraljud är det möjligt att undersöka lungorna på ett sätt som är harmlöst mot kroppens vävnader. Syftet med denna studie var att ta reda på om ultraljud kan ersätta konventionell lungröntgen för att diagnostisera barn med misstänkt pneumoni. Studien genomfördes som en allmän litteraturöversikt där 13 kvantitativa vetenskapliga artiklar granskades. Ultraljud är en tillförlitlig metod som har högre sensitivitet och specificitet när det gäller att detektera pneumoni än vad lungröntgen har. Ultraljud är även bättre på att detektera små förändringar i lungorna och pleurautgjutningar jämfört med lungröntgen. Ultraljud kan användas för att diagnostisera barn med pneumoni. Att införa den som en alternativ undersökningsmetod till lungröntgen när det kommer till att diagnostisera pneumoni skulle leda till minskade stråldoser för de barn som söker vård med misstänkt pneumoni. / Pneumonia is globally the largest cause of disease and mortality among children under the age of five years, with 920,000 deaths in 2015. In Sweden, pneumonia is the major cause of childhood disease, with a rapid onset of malaise, fever, chills and respiratory problems. It’s currently diagnosed with the help of clinical signs and chest x-ray, which exposes the children to ionizing radiation. With ultrasound it is possible to examine the lungs in a way that’s not harmful to the body tissues. The purpose of this study was to determine whether ultrasound can replace conventional chest x-ray to diagnose children with suspected pneumonia. The study was conducted as a general literature review where 13 quantitative scientific articles were examined. Ultrasound is a reliable method that has higher sensitivity and specificity when it comes to detecting pneumonia compared to chest x-ray. Ultrasound is also better at detecting small consolidations in the lungs and the presence of pleural effusion compared to chest x-ray. Ultrasound can be used to diagnose children with suspected pneumonia. Introducing it as an alternative method of examination to chest x-ray when it comes to diagnosing pneumonia would lead to reduced radiation doses for those seeking pediatric care with suspected pneumonia.
|
Page generated in 0.1252 seconds