• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 113
  • 88
  • 14
  • 11
  • 6
  • 6
  • 5
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 282
  • 282
  • 102
  • 100
  • 61
  • 44
  • 42
  • 39
  • 39
  • 26
  • 25
  • 23
  • 22
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Multielectrode platform for measuring oxygenation status in multicellular tumor spheroids

Sheth, Disha B. 25 April 2011 (has links)
No description available.
182

Reliability of the calculated maximal lactate steady state in amateur cyclists

Adam, Jennifer, Oehmichen, Matthias, Oehmichen, Eva, Rother, Janine, Müller, Ulrike Maria, Hauser, Thomas, Schulz, Henry 13 July 2015 (has links) (PDF)
Abstract provided by Publisher Complex performance diagnostics in sports medicine should contain maximal aerobic and maximal anaerobic performance. The requirements on appropriate stress protocols are high. To validate a test protocol quality criteria like objectivity and reliability are necessary. Therefore, the present study was performed in intention to analyze the reliability of maximal lactate production rate (VLamax) by using a sprint test, maximum oxygen consumption (VO2max) by using a ramp test and, based on these data, resulting power in calculated maximum lactate-steady-state (PMLSS) especially for amateur cyclists. All subjects (n=23, age 26 ± 4 years) were leisure cyclists. At three different days they completed first a sprint test to approximate VLamax. After 60 min of recreation time a ramp test to assess VO2max was performed. The results of VLamax-test and VO2max-test and the body weight were used to calculate PMLSS for all subjects. The intra class correlation (ICC) for VLamax and VO2max was 0.904 and 0.987, respectively, coefficient of variation (CV) was 6.3 % and 2.1 %, respectively. Between the measurements the reliable change index of 0.11 mmol∙l-1∙s-1 for VLamax and 3.3 ml∙kg-1∙min-1 for VO2max achieved significance. The mean of the calculated PMLSS was 237 ± 72 W with an RCI of 9 W and reached with ICC = 0.985 a very high reliability. Both metabolic performance tests and the calculated PMLSS are reliable for leisure cyclists.
183

Utrymning uppåt : Påverkan av vinterkläder vid utrymning uppåt via trappor

Neumann, Dorothea, Asplund, Mattias January 2016 (has links)
When cities grow larger the demand for more residential buildings and public transport increases. To be able to meet the demands and still make the city compact the interest for underground facilities grows. Underground facilities come with some drawbacks, one example is the evacuation where the people are expected to evacuate upwards. This master thesis is aiming to further develop the research done on the subject by examining the impact of winter clothing. Two tests were performed in Skrapan, which is 25 floors high. The participants went up for 22 of the floors and were recorded during the ascending. Some of the participants had a pulse watch and a breathing mask, which measured the oxygen consumption. The median for the walking speed varied between 0,81 m/s and 0,56 m/s with regular clothing and 0,78 m/s to 0,57 m/s with winter clothes. In the building codes it says that 0,6 m/s should be used when calculating evacuation times when ascending stairs. The heart rate did not change significantly between the two tests. However, the oxygen consumption was higher with the jacket on. The participants would not have been able to keep going for much longer than 5 minutes with their current pace. According to the results in this master thesis 0,6 m/s is too high because in the tests that were made the participants were physically active and still couldn’t keep that speed up for the whole test. Due to the test being two days in a row, almost all of the participants walked slower the second time. However, the ones that walked with winter clothes the second day walked more slowly than the ones with regular clothes compared to the first day. Therefore, it is safe to say that the clothes do affect the walking speed of evacuating people and that more clothes i.e. warm shoes or a hat will have an even greater impact. / I takt med att städerna växer, både till yta och befolkningsmängd, ökar behovet av infrastruktur bland annat inom kollektivtrafiken och transportvägar. Genom att bygga dessa anläggningar under marken går det att exploatera marken ovan till andra ändamål. Med undermarksanläggningar kommer vissa svårigheter, så som begränsade utrymningsmöjligheter. Riktlinjerna för utrymning uppåt är inte till för längre trappor, och är därför inte representativt för de nya användningsområdena. Vikten av att dimensionera utrymningsmöjligheterna utifrån vad dagens befolkning kan prestera är relevant för att säkerställa en trygg utrymning i händelse av en olycka. Examensarbetet inriktar sig därför på att vidareutveckla tidigare forskning om utrymning uppåt genom att undersöka hur gånghastigheterna i trappor påverkas av vinterkläder. Försök genomfördes med 21 personer under två dagar i ett av Skrapans utrymningstrapphus, där varje försöksperson fick gå en gång per dag. Mätmetoderna som användes var bland annat; pulsklocka, tidtagning, videoobservationer och andningsmask som mäter syreupptagningsförmågan. Medianen för gånghastigheten beräknades på varje våningsplan där de högsta värdet med vanliga kläder blev 0,81 m/s, 3 meter upp i trappan och det lägsta 0,56 m/s, 57 meter upp i trappan. Med vinterkläder blev motsvarande värden 0,78 m/s, 5 meter upp i trappan och 0,57 m/s, 33 meter upp i trappan. Enligt Boverkets allmänna råd om analytisk dimensionering ska den dimensionerande gånghastigheten i trappor sättas till 0,6 m/s. Denna riktlinje är inte godtagbar eftersom försökets urvalsgrupp hade svårt att hålla den hastigheten trots att majoriteten av försökspersonerna i examensarbetet var unga och i god kondition. Gånghastigheterna påverkades även av att försökstillfällena genomfördes dagarna efter varandra vilket gjorde att försökspersonerna inte hade möjlighet att återhämta sig helt mellan försöken. Dock var tidsskillnaden från första dagen till den andra större för de som gick med vinterkläder andra dagen än för de som gick med vanliga kläder andra dagen. Vilket visar på att försökspersonerna blivit påverkade av vinterkläderna och därför gått långsammare. Mätningarna av syreupptagningsförmågan hos försökspersonerna gav varierande resultat, mycket beroende på kön och om de hade vinterkläder på sig eller inte. Kvinnornas utnyttjande grad ökade från 70-85 % till 73-90 % av sin maximala syreförbrukning när de var iklädda vinterkläder. Jämfört med männens utnyttjande grad som sjönk från 63-85 % till 61-77 % vid användandet av vinterkläder. Försökspersonerna var nära sin maximala syreförbrukning, VO2,max, vilket tyder på att de inte skulle klara av att hålla samma tempo i en längre trappa. Männen skulle kunna hålla samma tempo i cirka 15 minuter medan kvinnorna som ligger på 90 % av sin kapacitet enbart skulle kunna hålla samma hastighet i cirka 5 minuter. Vilket är ett ytterligare tecken på att hastigheten i BBRAD är för hög i långa trappor.
184

Oxydation du sulfure d'hydrogène par les cellules épithéliales coliques : Une voie métabolique de détoxication et de production d'énergie

Mimoun, Sabria 02 December 2011 (has links)
Le sulfure d'hydrogène (H2S) est un métabolite bactérien produit notamment par les bactéries sulfato-réductrices du côlon à partir des acides aminés soufrés, des sulfates/sulfites alimentaires et des sulfomucines. A fortes concentrations, le H2S est un gaz toxique, de par sa capacité à inhiber la cytochome c oxydase, et par conséquent, la respiration mitochondriale. A l'inverse, notre travail montre qu'à faibles concentrations, le H2S induit une énergisation mitochondriale des cellules épithéliales coliques humaines HT 29 Glc-/+ lui conférant aussi un rôle de substrat minéral énergétique. Dans ce travail, nous avons déterminé les concentrations de H2S permettant l'oxydation/détoxication de H2S par les cellules HT 29 Glc-/+ et celles provoquant une inhibition de la consommation d'oxygène. L'oxydation du H2S nécessite la coopération entre la « sulfide oxidation unit » et la chaîne respiratoire. La capacité des cellules HT29 Glc-/+ à oxyder le H2S est associée à la présence des transcrits codant les enzymes constituant la « sulfide oxidation unit » : la sulfure d'hydrogène quinone reductase (SQR), la dioxygenase ETHE1 et la thiosulfate transferase (TST). Nous avons démontré la priorité de l'oxydation du H2S sur les substrats carbonés . En effet, nos résultats suggèrent que les électrons venant de la SQR sont transférés au pool d'ubiquinone aux dépens de ceux venant du complexe I. Nos résultats démontrent que la SQR joue un rôle déterminant pour l'oxydation de H2S. De plus, la détoxication du H2S par les cellules HT29 Glc-/+ augmente au cours de la différenciation spontanée ou induite par un traitement au butyrate. L'augmentation de la détoxication de H2S au cours de la différenciation est associée à une augmentation de la réserve respiratoire soulignant l'importance de la chaîne respiratoire comme composante de la fonction de détoxication du H2S. En situation d'inhibition de la cytochrome c oxydase, la grande capacité des cellules coliques humaines à détoxiquer le H2S pourrait être en partie due à la présence d'un transfert réverse des électrons issus de l'oxydation de H2S de la SQR vers le complexe I. Outre le butyrate, le zinc un autre composé de la lumière colique, exerce un effet protecteur contre la toxicité cellulaire du H2S. Enfin, notre travail a mis en évidence une diminution de l'expression d'un gène codant pour une enzyme de la « sulfide oxidation unit » (la TST) dans le rectum comparée à différents segments du côlon, ce qui pourrait correspondre à des capacités de détoxication du H2S différente en fonctions des segments du gros intestin humain. / Hydrogen sulfide (H2S) is a metabolite produced notably by colonic sulphate-reducing bacteria from alimentary sulphur-containing amino acids, sulfates / sulfites and sulfomucines. At high concentrations, H2S is a toxic gas due to its ability to inhibit cytochome c oxidase, and therefore mitochondrial respiration. In contrast, our study shows that at low concentrations, H2S induces mitochondrial energization in human colonic epithelial cells HT-29 Glc -/+ assigning it a role as the first inorganic oxidative substrate in human cells. In this work, we have determined sulphide concentrations allowing sulphide oxidation/detoxification by HT-29 cells and those which inhibit oxygen consumption. The oxidation of H2S requires cooperation between the “sulphide oxidation unit” and the respiratory chain. The capacity of HT-29 Glc -/+ to oxidize H2S is associated with the presence of transcripts encoding the enzymes constituting the “sulfide oxidation unit”: the sulphide quinine reductase (SQR), the sulphur dioxygenase or Ethylmalonic encephalopathy 1 (ETHE1) and the thiosulfate sulphur transferase (TST). We demonstrate that the oxidation of H2S takes precedence over the oxidation of carbon substrates. Indeed, our results suggest that electrons from SQR are transferred to the ubiquinone pool at the expense of those originating from the complex I. Our results point out that SQR represents a determinanat factor in the oxidation of H2S. In addition, the detoxification of H2S by HT-29 Glc -/+ cells increases during spontaneous differentiation and differentiation induced by treatment with butyrate. The increase in the detoxification of H2S during the differentiation is associated with an increase of the respiratory reserve pointing out the importance of the respiratory chain as a component of the detoxification function of H2S. In situations of inhibition of cytochrome c oxidase, the capacity of human colon cells to detoxify H2S could be due in part to the presence of a reverse transfer of electrons from the oxidation of H2S to the SQR complex I. In addition to butyrate, zinc, another compound of the colonic lumen has a protective effect against cell toxicity associated with H2S. Lastly, we have shown a decreased expression of the gene encoding an enzyme of the “sulfide oxidation unit” (TST) in the rectum compared to the other segments of human colon. This observation may correspond to different detoxification capacities towards H2S according to the different parts of the human large intestine.
185

Porovnání obecných a specifických funkčních zátěžových testů u skialpinistů / Comparison of universal and specific functional stress tests of ski- mountaineerers

Formánková, Dita January 2011 (has links)
Title: Comparison of universal and specific functional stress tests of ski-mountaineerers. Objectives: The aim of the thesis is to compare maximal functional parameters of ski-mountaineerers measured during three functional laboratory stress tests. The functional stress tests were set on a treadmill, bicycle ergometer, and on a ski-mountaineer trainer. Consecutively, there is evaluated the meaning of testing of the functional parameters on the ski-mountaineer trainer. Methods: Interindividual and intraindividual descriptive study of 10 ski-mountaineerers of middle and high level performance. Results: The respondents reached the average value of VO2max 63,3 ml.kg-1 .min-1 on the ski-mountaineer trainer, 67,5 ml.kg-1 .min-1 on a treadmill and 66,5 ml.kg-1 .min-1 on a bicycle ergometer. The average measured HR on the ski-mountaineer trainer was 179 heartbeats/min, on the treadmill 185 heartbeats/min and on the bycicle ergometer 183 heartbeats/min. The average value of R reached the value of 1,09 on the ski-mountaineer trainer, 1,18 on the treadmill and 1, 19 on the bycicle ergometer. The highest measured value of VO2max reached on the treadmill was 79,3 ml.kg-1 .min-1 , the bycicle ergometer enabled to reach maximum 76,5 ml.kg-1 .min-1 and the highest value reached on the ski-mountaineer trainer was...
186

Metabolismo oxidativo e estado redox tecidual dependente da função e do estado nutricional de operárias de Apis mellifera L. / Oxidative metabolism and redox state dependent on the function and nutritional status of Apis mellifera L. workers

Cervoni, Mário Sergio 03 December 2018 (has links)
As operárias de Apis mellifera realizam diferentes tarefas de acordo com a sua idade (polietismo etário), sendo que operárias jovens cuidam da cria e quando mais velhas forrageiam. Entretanto, tal transição não segue uma cronologia fixa, mas se ajusta às necessidades da colônia, especialmente as condições nutricionais, tanto da colônia quanto dos indivíduos. Nesse sentido, abordamos a questão de como o metabolismo oxidativo no corpo gorduroso das operárias, i.e., o centro do metabolismo intermediário destes insetos, está relacionado com alterações da função das operárias na colônia e como o mesmo responde a um estresse nutritivo imposto individualmente em duas fases, na fase larval e na fase adulta. Como métodos para avaliar a atividade mitocondrial e o estado redox das células do corpo gorduroso utilizamos um sistema de respirometria de alta resolução para medir o consumo de O2, e realizamos ensaios bioquímicos para quantificar a geração de espécies reativas de oxigênio (EROs), os níveis de óxido nítrico, o número de unidades mitocondriais, e eventuais danos oxidativos resultantes. Ademais, por meio de PCR quantitativa medimos a expressão relativa de genes ligados à biogênese mitocondrial, ao sistema antioxidante e à via de sinalização por hipóxia. Na comparação destes parâmetros entre operárias nutridoras e forrageiras avaliamos separadamente os três principais compartimentos do corpo (cabeça, tórax e abdômen) uma vez que esses estão diferencialmente relacionados a tais funções. Para os tecidos da cabeça observamos que as amostras de nutridoras apresentaram maior consumo de O2, associado a uma maior produção de EROs e expressão elevada dos genes da via de hipóxia, enquanto forrageiras apresentaram maiores quantidades de transcritos dos genes do sistema antioxidantes e menores níveis de danos oxidativos. Para os tecidos do tórax observamos nas forrageiras uma maior capacidade de produção de ATP, acompanhada de uma elevada expressão de genes codificadores de enzimas do sistema antioxidante e menores níveis de danos oxidativos. Com relação aos tecidos abdominais, as abelhas nutridoras apresentaram maior atividade mitocondrial, enquanto as amostras de forrageiras apresentaram maior número de unidades mitocondriais, elevados níveis EROs e também uma expressão elevada dos genes do sistema antioxidante e da via de hipóxia. Assim, os dados revelaram uma clara mudança na atividade mitocondrial e nos padrões redox teciduais associados a esta transição de polietismo etário. Também notamos diferenças nestes parâmetros para cada compartimento do corpo analisado, refletindo uma demanda energética diferencial em cada tecido. A segunda parte do projeto teve como objetivo avaliar os mesmos parâmetros redox em uma situação de restrição alimentar em três situações distintas. O primeiro grupo experimental foi constituído de larvas que sofreram restrição calórica por umperíodo de 10 horas. O segundo grupo foi composto por abelhas recém emergidas que sofreram ou não tal restrição calórica no período larval. O terceiro grupo consistiu de abelhas que sofreram ou não restrição calórica no período larval, e após emergirem foram mantidas em caixas até atingirem a idade de 7 dias, quando foram submetidos novamente a uma restrição calórica. Para o primeiro grupo, as larvas, verificamos que após o período de restrição calórica os genes relacionados com a biogênese mitocondrial e o sistema antioxidante apresentaram níveis de expressão menores comparadas com larvas controle. Observamos também que larvas que sofreram restrição calórica apresentaram menor consumo de O2 e menores níveis de EROs. Para o segundo grupo, as abelhas recém emergidas, não observamos nenhuma diferença na expressão de genes mitocondriais e do sistema antioxidante entre as que sofreram ou não restrição calórica na fase larval, demostrando uma recuperação nestes parâmetros após o período de metamorfose. No terceiro grupo, as abelhas de 7 dias foram submetidas a uma nova restrição calórica para observar se indivíduos que passaram por a situação de estresse no período larval apresentariam uma resposta mais imediata a um estresse nutricional na fase adulta. Os resultados do terceiro grupo revelaram que abelhas que haviam sido expostas a uma situação prévia de restrição calórica, apresentaram uma redução dos transcritos de genes ligados a biogênese mitocondrial e do sistema antioxidante quando comparados ao grupo que sofreu restrição calórica apenas na fase adulta. Em conjunto nossos dados sugerem que a restrição calórica é capaz de diminuir o metabolismo oxidativo e que existe uma resposta aparentemente adaptativa em indivíduos adultos que passaram por essa situação previamente durante o desenvolvimento larval. Assim, esses resultados podem servir para direcionar estudos futuros sobre a relação entre restrição calórica, metabolismo oxidativo e longevidade nesses insetos sociais. / Apis mellifera workers perform different tasks according to their age (age polyethism), where young workers care for the brood and older ones become foragers. However, this a transition does not follow a fixed chronology, but is fitted to the needs of the colony, especially the nutritional conditions of both, the colony and the individual bee. In this sense, we address the question of how oxidative metabolism in the fat body of the workers, e.g., the center of the intermediary metabolism of these insects, is related to changes in the function of the workers in the colony, and how these parameters responds to a nutritional stress imposed individually in two stages, in the larval and adult phase. For evaluating mitochondrial activity and the redox status of fat body cells we used a high resolution respirometry system to measure O2 consumption, and we performed biochemical assays to measure the generation of reactive oxygen species (ROS), levels of nitric oxide, the number of mitochondrial units, and eventual oxidative damages. Furthermore, using quantitative PCR, we measured the relative expression of genes linked to mitochondrial biogenesis, to the antioxidant system, and to the hypoxia signaling pathway. In the comparison of these parameters between nurse and forager workers, we evaluated separately the three main body compartments (head, thorax and abdomen), since these are differentially related to these functions. For the head tissues, we observed that nurses showed higher O2 consumption, associated with higher ROS production and elevated expression of hypoxia pathway genes, while foragers presented higher amounts of transcripts of the antioxidant system genes and lower levels of oxidative damages. For the thorax tissues we found in the foragers a greater capacity of ATP production, accompanied by a higher expression of genes encoding enzymes of the antioxidant system and lower levels of oxidative damage. With respect to the abdominal tissues, nurse bees presented higher mitochondrial activity, while foragers had a higher number of mitochondrial units, elevated ROS levels, and also a higher expression of genes related to the antioxidant system and hypoxia pathway. Thus, these data revealed a clear change in mitochondrial activity and redox tissue patterns associated with this transition of age polyethism. We also noticed differences in these parameters for each of the analyzed body compartment, reflecting a differential energy demand in each tissue. The second part of the project aimed to evaluate the same redox parameters in a food restriction condition in three distinct situations. The first experimental group consisted of larvae that experienced caloric restriction for a 10 hour period. The second group consisted of newly emerged bees that had or not experienced such a caloric restriction in the larval period. The third group consisted of bees that had experienced or not caloric restriction during the larval period, and after emergence were kept in boxes until reaching 7 days old, when they were resubmitted to another caloricrestriction. For the first group, the larvae, we found that after the period of caloric restriction, genes related to mitochondrial biogenesis and the antioxidant system presented lower levels of expression compared to control larvae. We also observed that larvae that had experienced caloric restriction presented lower O2 consumption and lower ROS levels. For the second group, newly emerged bees, we did not observe any differences in the expression of mitochondrial genes and the antioxidant system among those individuals that had experienced or not caloric restriction in the larval phase, indicating a recovery in these parameters after the period of metamorphosis. In the third group, the 7-day-old bees had experienced a new caloric restriction to see whether individuals that had been in a stressful situation during larval period would respond more readily to nutritional stress in adulthood. The results for this group showed that bees that had been exposed to a previous caloric restriction presented a reduction in the transcript levels of genes related to mitochondrial biogenesis and the antioxidant system when compared to the group that experienced caloric restriction only in adulthood. Taken together, our data suggest that caloric restriction is able to diminish the oxidative metabolism, and that there is a seemingly adaptive response in adult individuals that had previously experienced this situation during larval development. Thus, these results can serve to direct future studies on the relationship between caloric restriction, oxidative metabolism and longevity in these social insects.
187

Respostas cardiopulmonares e metabólicas do teste do degrau incremental modificado em indivíduos com asma / Cardiopulmonary and metabolic responses of incremental step test evaluate maximal exercise capacity in subjects with asthma

Barbosa, Renata Cleia Claudino 26 April 2019 (has links)
O teste de exercício cardiopulmonar (TECP) (ou teste ergoespirométrico) é considerado o padrão-ouro para avaliação da potência aeróbia, contudo este teste demanda equipamentos sofisticados e profissionais especializados. O interesse pelo teste do degrau para avaliação da capacidade física em indivíduos com doenças pulmonares crônicas cresceu nos últimos anos devido à sua portabilidade. Entretanto, o uso do teste do degrau incremental (TDIM) para avaliação da capacidade física de indivíduos com asma permanece desconhecido. O objetivo deste estudo foi avaliar as respostas cardiopulmonares e metabólicas durante o TDIM em indivíduos com asma moderada a grave bem como avaliar sua reprodutibilidade nesta população. Cinquenta e quatro indivíduos com asma moderada a grave foram submetidos ao TECP e a dois TDIM em ordem aleatorizada. Os testes foram realizados em 2 dias não consecutivos com intervalo mínimo de 48 horas. No primeiro dia, os indivíduos realizaram avaliação do controle clínico da asma pelo Asthma Control Questionnaire (ACQ) e o teste TECP ou os 2 TDIM, de acordo com a aleatorização. Na segunda visita, os indivíduos foram submetidos aos 2 TDIM ou ao TECP de acordo com a aleatorização. Os dados dos pacientes foram analisados em subgrupos de acordo com o índice de massa corpórea (IMC) e divididos em eutróficos, sobrepeso e obesos. O desempenho no melhor TDIM (m-TDIM) foi comparado à resposta do TECP. Os valores de consumo de oxigênio no pico do exercício (VO2pico) obtidos no m-TDIM foram inferiores ao TECP (2.042±494; 1.749±434 ml/min, média±DP, respectivamente; p=0,01). Os limites de concordância do VO2pico entre o m-TDIM e TECP variaram de -786 a 201 ml/min. Não foi observada diferença nos indivíduos eutróficos com asma (EA) na maioria das variáveis analisadas, exceto no coeficiente respiratório (RER). Por outro lado, foi verificado que a maioria das variáveis obtidas no TDIM foram inferiores nos indivíduos com sobrepeso e obeso comparado ao TECP. Apesar dos valores inferiores observados no m-TDIM quando comparado ao TECP na análise com todos os indivíduos, o TDIM se mostrou reprodutível e apresentou um excelente coeficiente de correlação intraclasse para o número de degraus (0,88[0,79 - 0,93]), o VO2pico (0,93[0,88 - 0,96]) e a frequência cardíaca máxima (0,86 [0,76 - 0,92]). Os nossos resultados mostram que o TDIM induz a uma menor resposta do VO2 pico quando comparado ao TECP em indivíduos com asma moderada a grave independente do IMC. Contudo, o TDIM foi bem tolerado e reprodutível nesta população / The cardiopulmonary exercise test (CPET) is the gold standard to measure aerobic fitness; however, CPET is expensive and requires specialized equipment and a qualified operator. There is a growing interest in using step tests to assess exercise capacity in subjects with chronic lung diseases due to its portability. However, the use of modified incremental step test (MIST) to evaluate exercise capacity in subjects with asthma remains unknown. This study aims to evaluate cardiopulmonary and metabolic responses during MIST in adults with moderate to severe asthma. In addition, we investigated the reliability of the MIST in this population. Fifty-four adults with asthma performed a CPET and two MIST with pulmonary gas analysis on two separate days in a randomized order. The tests were performed in 2 non-consecutive days with a minimum interval of 48 hours. On the first day was evaluated the clinical control of asthma by the Asthma Control Questionnaire (ACQ) and the TECP or 2 TDIM, according to the randomization. At the second visit, the subjects were submitted to 2 TDIM or TECP according to the randomization. The subjects were allocated according to BMI (body mass index) in eutrophic, overweight and obese. The best MIST (b-MIST) was considered at the peak of the exercise for comparison with CPET. There was a difference in peak oxygen uptake (VO2peak) assessed by the CPET and the b-MIST (2,042±494; 1,749±434 ml/min, mean ± SD, respectively; p=0.01). The limits of agreement for VO2peak between the CEPT and the b-MIST with ranged from -786 to 201ml/min. MIST was reproducible and presented an excellent intraclass correlation coefficient (CCI [95% confidence interval]) for the number of steps (0.88[0.79 - 0.93]), VO2 (0.93[0.88 - 0.96]) and maximal heart rate (0.86 [0.76 - 0.92]). The MIST elicits a lower VO2peak than the CPET in subjects with moderate to severe asthma regardless the BMI. However, the MIST is well tolerated and reproducible in this population
188

Ontogênese do ritmo de consumo de oxigênio em operárias de Melipona quadrifasciata (Hymenoptera; Meliponini): a influência da luz / Ontogenesis of respiratory rhythms in Melipona quadrifasciata workers: the influence of light

Camargo, Jéssica Martins 26 April 2012 (has links)
As operárias de Melipona quadrifasciata exercem diferentes funções na colônia, segundo sua faixa etária. No interior da colônia, os indivíduos mais jovens, nutrizes, ficam localizados na região mais interna e aproximam-se progressivamente das regiões periféricas à medida que envelhecem. Os indivíduos mais velhos, forrageiras, saem da colônia diariamente. Ritmos biológicos estão presentes nas operárias de todas as idades, mas apenas os ritmos das forrageiras estão bem caracterizados. Neste trabalho, o objetivo foi detectar mudanças no sistema temporal que ocorrem ao longo do desenvolvimento ontogenético de abelhas operárias. O ritmo monitorado foi aquele de consumo de O2, empregando um ciclo claro/escuro como agente sincronizador. O consumo de O2 foi registrado em nutrizes com 24 horas de vida e em forrageiras, sendo que as nutrizes foram divididas em dois grupos: Nutri_BOD, indivíduos colocados em condições constantes de temperatura e iluminação assim que emergiam do favo, e NUTRI_Col, indivíduos devolvidos à colônia por 24 horas antes dos testes. O protocolo experimental foi dividido em três fases: Fase1, forrageiras e Nutriz_BOD eram mantidos em condição constante de iluminação e temperatura durante 24 horas. Nutriz_Col era devolvida a colônia de origem durante esse mesmo intervalo; Fase2, exposição a ciclo claro/escuro 12:12h durante 48 horas; Fase3, todos os indivíduos voltavam às condições ambientais constantes. Em Fase2 e Fase3 foram feitas as medidas de consumo de O2. Os resultados da Fase2 não mostraram arrastamento, período significativo do ritmo difere de 24h. A média de consumo na fotofase apresenta diferença significativa da média de consumo na escotofase, para o grupo das forrageiras e Nutri_Col, sendo o consumo maior na fotofase. Ritmos em livre curso foram encontrados em todas as forrageiras e em 25% das nutrizes de ambos os grupos. Os resultados indicam a existência de um processo de maturação do sistema circadiano, bem como na capacidade de lidar com a luz, que representa uma situação desfavorável à sobrevivência das nutrizes. Como os dois grupos de nutrizes apresentaram ritmos endógenos, o surgimento deles independe da influência da colônia. A colônia, porém, parece modular a velocidade do estabelecimento do ritmo e sua capacidade de sincronizar-se com o ciclo claro/escuro ambiental. / The workers of the stingless bee, Melipona quadrifasciata, assume different tasks during their adult life. Newly emerged individuals - nurses - remain inside the nest, without contact with the external environment. As the workers mature, they migrate to more peripheral regions but only the oldest - foragers - leave the nest. Foragers have strong daily rhythms. Biological rhythms have already been detected in all the workers, but only the rhythms of foragers are well characterized. This work aimed to detect changes in temporal biological system during post-embryonic development. For this, the rhythm of oxygen consumption was measured and light/dark cycle was used as the synchronizing agent. Oxygen consumption was monitored in foragers and in nurses 24 hours after the emergence. The nurses were divided into two groups: 1-Nutri_BOD: the bees were kept in constant conditions of temperature and illumination. 2- NUTRI_Col: newly emerged workers were transferred back to the colony for 24 hours before the experiment. The experimental protocol was divided into three parts: 1- Forager and Nutriz_BOD were kept in constant conditions of illumination and temperature for 24 hours. Nutriz_Col were returned to the colony during the same interval. 2- Animals were exposed to a light/dark cycle, 12:12h, for 48 hours. 3- All the bees returned to constant conditions, for 4 days. Mesurements of O2 consumption were taken during the second and third parts of the experiment. There was not entrainment of the individual\'s rhythms. The period was different from 24h. In foragers and Nutri_Col there were significant differences between the average consumption in the photophase and the average consumption in the scotophase. A free running rhythm was present in all foragers and in 25% of Nutri_Col and Nutri_BOD. Results indicate the existence of a process of maturation running in the circadian system, and an increasing ability to respond to light. Presence of light is a non-permissive condition for the nurses\' survival. Endogenous rhythms are present in both groups of nurses. The presence of the colony is not necessary to the development of the rhythm. However, the colony seems to modulate the rate of to the development and the ability to synchronize with the light/dark cycle.
189

Função endotelial em crianças pré-púberes com cardiomiopatia dilatada idiopática, insuficiência cardíaca com fração de ejeção de ventrículo esquerdo preservada e saudáveis / Endothelial function in prepubertal children with idiopathic dilated cardiomyopathy, heart failure with preserved left ventricular ejection fraction and healthy ones

Tavares, Aline Cristina 09 June 2016 (has links)
Adultos com insuficiência cardíaca (IC) desencadeada por cardiomiopatia dilatada idiopática (CMDid) apresentam disfunção endotelial. Esta, por sua vez, está relacionada a baixo prognóstico. Assim, o objetivo principal desse estudo foi avaliar a função endotelial de crianças com CMDid e com IC por CMDid prévia e função de ejeção do ventrículo esquerdo (FEVE) preservada. O estudo, então, foi composto por três grupos. O grupo CMDid foi composto de 15 crianças com CMDid e FEVE<40%.O grupo IC foi composto de 16 crianças com IC por CMDid prévia e FEVE > 50%. O grupo controle (CON) foi composto de 11 crianças saudáveis. As crianças dos três grupos foram submetidas a avaliações de função endotelial pelo índice de hiperemia reativa (RHI), ergoespirometria e classificação da classe funcional. Os resultados mostram que a estatura das crianças do CMDid foi menor que a das crianças do CON (1,20 ± 0,20 contra 1,40 ± 0,10; p=0,02). A FEVE foi significativamente menor no CMDid (35,2 ± 10,4) em comparação com a no IC (59,1 ± 5,9) e no CON (62,5 ± 3,4; p=0,0001). Os valores de RHI do CON se apresentaram significativamente 31% maiores que o CMDid e 25% maiores no IC, de forma que houve efeito principal significativo estatisticamente apenas para o grupo em relação à variável RHI [F(2,39)=10,310;p < 0,001; ?2=0,35; poder = 0,98].As crianças do CMDid apresentaram os valores de RHI e de pressão arterial sistólica no pico do exercício significantemente menores que as crianças do IC e do CON. A FEVE esteve moderadamente correlacionada com os valores do RHI (r=0,46; p < 0,006). Para cada unidade de medida de RHI, houve um acréscimo de 10,5 no VO2max. Os menores valores de RHI estiveram diretamente correlacionados com os menores valores de VO2max (r=1; p =< 0,01). A classificação de Weber foi significativamente associada às três classes funcionais (da criança, do responsável e do médico) / Adults with heart failure (HF) due to idiopathic dilated cardiomyopathy (DCM) have endothelial dysfunction. The latter is related to poor prognosis. Therefore, the primary aim of this study was to evaluate endothelial function in children with DCM, with HF due to previous DCM and preserved left ventricular ejection fraction (LVEF). The study was composed by three groups. CMDid group was composed by 15 DCM children with LVEF < 40%.ICgroup was composed by 16 HF children (by previous DCM) with LVEF > 50%. Control group (CON) was composed by 11 healthy children. All children were assessed by endothelial function via reactive hyperemia-peripheral artery tonometry (RH-PAT) testing, CPT and functional class classification. The results point that CMDid children were shorter than CON (1.20 ± 0.20 contra 1.40 ± 0.10; p=0.02). LVEF was significantly lower in children from CMDid (35.2 ± 10.4) compared to those from IC (59.1 ± 5.9) and from CON (62.5 ± 3.4; p=0.0001). CON had significant higher RHI values than CMDid in 31% and than IC in 25%.There was statistically significant main effect only for group in relation to the variable RHI [F(2,39)=10.310;p < 0.001; ?2=0.35; power = 0.98]. Children in CMDidhad significantly lower values of RHI and lower systolic pressure at peak of exercise than ICand CON. LVEF was moderate correlated to RHI values (r=0.46; p < 0.006). For each point of RHI, there is an addition of 10.5 in the VO2max. Lower RHI values were correlated to lower VO2max values (r=1; p =< 0.01).Weber\'s classification was significantly associated to the three functional classes (children\'s self report, parents\' and medical\'s)
190

Elaboração, validação e reprodutibilidade de um protocolo para mensurar a potência aeróbia utilizando movimentos específicos do judô / Protocol elaboration, validation and reliability for aerobic power measurement using specific judo movements

Shiroma, Seihati Ari 23 January 2019 (has links)
O judô é um esporte de combate com características intermitentes, com alta demanda fisiológica. O desenvolvimento da potência aeróbia máxima em atletas de judô pode contribuir para a recuperação e a manutenção da intensidade dos esforços durante o combate, e para a recuperação entre os diferentes combates de uma competição. Em geral, a avaliação dessa capacidade física tem sido realizada por meio da aplicação de testes progressivos até a exaustão em esteira ou ciclo-ergômetro, os quais possuem baixa validade ecológica e não permitem a obtenção de parâmetros para a prescrição do treinamento específico da modalidade. Dessa forma, o objetivo deste estudo foi elaborar e testar a validade, reprodutibilidade e sensibilidade de um teste progressivo até a exaustão utilizando-se do uchi-komi (entrada de golpes), para mensurar a potência aeróbia máxima de atletas de judô. Doze atletas de judô do sexo masculino participaram desse estudo e foram submetidos a quatro sessões de avaliação, em dias distintos e, separadas por um intervalo de, no mínimo, 48 horas, exceto para a última sessão, que foi conduzido sete dias após a realização da terceira sessão. Para determinar a validade de critério, foram conduzidos três testes progressivos até a exaustão: teste de membros superiores (MMSSteste), membros inferiores (MMIIteste) e teste de uchi-komi (UKteste), os quais foram aleatorizados e distribuídos entre a primeira e a segunda sessões. Na etapa seguinte os mesmos atletas foram avaliados na terceira e quarta sessões para determinar a reprodutibilidade do UKteste. Além disso, também foi confirmado se os atletas alcançaram o verdadeiro consumo máximo de oxigênio, por meio de um teste de confirmação (UKconf). Para essa finalidade, 12 atletas de judô, incluindo 6 atletas que participaram do estudo de validade e reprodutibilidade, realizaram dois testes (UKteste e UKconf), separados por um intervalo de 20 minutos. A análise descritiva de todas as variáveis dependentes foi apresentada como média e desvio padrão. A validade do UKteste foi determinado por intermédio de uma análise de variância a um fator (tipo de teste) pela comparação do UKteste, MMSSteste e MMIIteste e pelo coeficiente de correlação de Pearson. Quando observada diferença significante, foi conduzido o teste de post-hoc de Bonferroni. A reprodutibilidade do UKteste foi determinada por meio do teste t de Student para dados pareados, coeficiente de correlação intraclasse (CCI), erro típico (ET) e ET como coeficiente de variação (CV). A sensibilidade do UKteste foi calculada pela menor variação detectável (MVD) para diferentes tamanho de efeito (0,2; 0,6 e 1,2 multiplicado pelo desvio padrão entre sujeitos) e classificados como marginal, médio, e bom, respectivamente. Além disso, a mínima mudança detectável (MMD) em uma dada variável foi calculada por meio da equação: ET x 1,96 * ?2. O nível de significância foi estabelecido em p < 0,05. A validade do UKteste foi confirmado pelo coeficiente de correlação de Pearson com valores de consumo pico de oxigênio (V? O2pico) classificados como quase perfeita. Não houve diferença nas variáveis mensuradas no UKteste e UKconf, além disso, os resultados mostraram que o UKteste possui boa reprodutibilidade relativa com CCI classificado como muito alta para a percepção subjetiva de esforço e quase perfeita CCI para o V? O2pico, frequência cardíaca máxima e intensidade aeróbia máxima. Adicionalmente, o teste apresentou boa reprodutibilidade absoluta, apresentando um ET como CV menor que 5%. Variações médias no tamanho do efeito podem ser adequadamente detectadas para o V? O2pico, intensidade aeróbia máxima e frequência cardíaca máxima. Em conclusão, o UKteste mostrou ser um teste válido e reprodutível para avaliar a potência aeróbia máxima de atletas de judô / Judo is a combat sport with intermittent characteristics and high physiological demand. The development of maximal aerobic power in judo athletes can contribute to the recovery and maintenance of efforts intensity during a combat, and to the recovery between different combats in a competition. In general, the evaluation of this physical capacity has been performed through the application of graded exercise tests in treadmill or cycle ergometer, which have low ecological validity, and do not enable the collection of parameters for specific training prescription to the modality. Thus, the objective of this study was to elaborate and test the validity, reliability and usefulness of a graded exercise tests using uchi-komi (repetition training), to measure the maximal aerobic power of judo athletes. Twelve male judo athletes participated in this study. They were submitted to 4 assessment sessions on different days separated by at least 48 hours, except in the last session which was performed 7 days after the 3rd session. In order to determine the criterion validity, 3 graded exercise tests were performed: upperbody (UBtest), lower-body cycle ergometer tests (LBtest) and uchi-komi (UKtest), which were randomized and distributed between 1st and 2nd sessions. In the next step, the same athletes were evaluated in the 3rd and 4th sessions to determine the reliability of the UKtest. Further, it was also confirmed whether athletes achieved true maximum oxygen uptake through a confirmation test (UKconf). For this purpose, 12 judo athletes, including 6 athletes who participated in the validity and reliability studies, performed 2 tests (UKtest and UKconf), separated by a 20-minute interval. The descriptive analysis of all dependent variables was presented by mean and standard deviations. The validity of the UKtest was determined through a one-way analysis of variance (test type), comparing the UKtest, UBtest and LBtest, and by the Pearson correlation coefficient. When a significant difference was observed, the Bonferroni post-hoc test was conducted. The UKtest reliability was determined by the test-retest comparison, using Student\'s t-test for paired data, intraclass correlation coefficient (ICC) and typical error (TE) as coefficient of variation (CV). The UKtest usefulness was calculated by the smallest worthwhile change (SWC) for different effect sizes (0.2, 0.6 and 1.2 multiplied by the standard deviation among subjects) and classified as marginal, average and good, respectively. In addition, the minimal detectable change (MDC) in each variable was calculated using the equation: TE × 1,96 × ?2. The significance level was set at p < 0.05. The validity of the UKtest was confirmed by the Pearsom correlation coefficient with values of peak oxygen consumption (V? O2peak) classified as nearly perfect. There were no differences between variables measured in the UKtest and in the UKconf. Also, results showed that the UKtest had good relative reliability, with ICC classified as very large (rated perceived exertion) and almost perfect (V? O2peak, maximal heart rate and maximum aerobic intensity). Moreover, the test presented good absolute reliability, with a TE as CV lower than 5%. Mean variations in effect size could be adequately detected for V? O2peak, maximal aerobic intensity and maximal heart rate. In conclusion, the UKtest proved to be a valid and reliable test to evaluate the maximal aerobic power of judo athletes

Page generated in 0.3168 seconds