• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 52
  • 30
  • 5
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 131
  • 58
  • 30
  • 29
  • 21
  • 21
  • 19
  • 14
  • 13
  • 11
  • 11
  • 11
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Efeitos da terapia de ressincronização cardíaca no remodelamento ventricular reverso de pacientes com cardiopatia dilatada não isquêmica: avaliação pela ecocardiografia tridimensional / Effects of cardiac resynchronization therapy on left ventricular reverse remodeling in patients with non ischemic dilated myocardiopathy: evaluation by three dimensional echocardiography

Viviane Tiemi Hotta 18 June 2010 (has links)
Introdução: A terapia de ressincronização cardíaca (TRC) tem se mostrado como um tratamento eficaz no tratamento de pacientes com insuficiência cardíaca (IC) grave e distúrbio da condução ventricular. A ecocardiografia tridimensional (Eco 3D) consiste em uma nova modalidade diagnóstica com resultados promissores para a identificação da dissincronia cardíaca e avaliação dos resultados da TRC. Objetivos: Estudar os efeitos da TRC no remodelamento reverso do ventrículo esquerdo (VE), em pacientes com miocardiopatia não isquêmica, insuficiência cardíaca e distúrbio da condução intraventricular, por meio da ecocardiografia tridimensional em tempo real. Métodos: De janeiro de 2007 a junho de 2009, foram avaliados 24 pacientes com miocardiopatia dilatada não isquêmica, IC classe funcional (CF) III ou IV (NYHA), com tratamento medicamentoso otimizado, QRS > 120 ms ao eletrocardiograma, e fração de ejeção do ventrículo esquerdo (FEVE) < 0,35 submetidos à TRC. Os pacientes foram avaliados antes, três e seis meses após TRC pela CF (NYHA), qualidade de vida pelo escore de Minnesota (MLHFQ), eletrocardiograma (intervalo PR e duração do QRS), ecocardiograma bidimensional (volumes diastólico VDVE, e sistólico VSVE, do ventrículo esquerdo, fração de ejeção ventricular esquerda - FEVE), Doppler tecidual (TDI) (avaliação da dissincronia cardíaca) e análise tridimensional (VDVE, VSVE, FEVE e dissincronia pela análise do SDI systolic dyssynchrony index). Foi considerado remodelamento reverso redução > 15% do VSVE após a TRC. As diferenças das médias das variáveis contínuas foram analisadas com o teste T não pareado, entre os grupos respondedor e não respondedor, depois de satisfeita a condição de normalidade. Antes da TRC, foi realizada uma análise univariada das características clínicas, eletrocardiográficas e ecocardiográficas para a construção de um modelo de regressão logística. Resultados: 9/24(38%) dos pacientes analisados apresentaram remodelamento ventricular reverso após TRC. O grupo respondedor apresentou menores volumes ventriculares (VDVE: 230 + 35 ml vs 316 + 10 ml, p = 0,045; VSVE: 178 + 30 ml vs 238 + 10 ml, p = 0,047), avaliados pelo método de Simpson, além de maior dissincronia cardíaca, avaliada pelo Eco 3D (SDI:13 + 3% vs 9 + 3%, p = 0,005) e pelo TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). Após a análise de regressão logística, o SDI (SDI > 11%) foi o único fator independente na predição de remodelamento reverso, seis meses após a TRC (sensibilidade:0,78; especificidade:0,79). Conclusões: O Eco 3D foi eficaz na detecção do remodelamento reverso do VE após a TRC, por meio da detecção da redução dos volumes ventriculares esquerdos (VDVE, VSVE) e da melhora da FEVE. O SDI foi o único preditor independente de remodelamento reverso após a TRC. Apresentaram menor taxa de resposta seis meses após a TRC, os pacientes com maiores volumes ventriculares esquerdos e menor fração de ejeção ventricular esquerda. A TRC melhorou a CF (NYHA) de IC e a qualidade de vida pelo escore de Minnesota / Introduction: Cardiac resynchronization therapy (CRT) consists of an effective treatment for patients with severe heart failure and ventricular conduction disturbance. Three dimensional echocardiography (3D Echo) is a new diagnostic modality with promising results in the identification of cardiac dyssynchrony and for the evaluation of CRT results. Objectives: To evaluate the effects of CRT in the left ventricular (LV) reverse remodeling in patients with non ischemic dilated myocardiopathy, heart failure and intraventricular conduction disturbance by using three dimensional echocardiography. Methods: From January, 2007 to June, 2009, twenty-four consecutive patients with heart failure, sinus rhythm, QRS > 120 ms, and Functional Class III or IV (NYHA), despite optimized medical treatment and left ventricular ejection fraction (LVEF) < 0,35, underwent CRT. All patients were assessed regarding Functional Class (NYHA), and the quality of life was evaluated using the Minnesota Living with Heart Failure Questionnaire (MLHFQ). All patients were submitted to an electrocardiogram, two dimensional echocardiography (2D Echo) including the evaluation of cardiac dyssynchrony by Tissue Doppler Imaging (TDI) and 3D Echo (SDI - systolic dyssynchrony index), before, three and six months after CRT. Left ventricular reverse remodeling was defined as a reduction of at least 15% of the left ventricular systolic volume (LVSV) after CRT. The difference between the mean of the continuous variables were compared by students T test, after being tested for normality. Before CRT, it was performed a univariate analysis of clinical, electrocardiographic and echocardiographic baseline characteristics of the patients for the construction of a logistic regression model. Results: 9/24 (38%) of the patients presented with left ventricular reverse remodeling six months after CRT. Patients who presented LV reverse remodeling had smaller left ventricular volumes estimated by Simpsons rule (LV diastolic volume (LVDV): 230 + 35 ml vs 316 + 10 ml, p = 0,045; LVSV: 178 + 30 ml vs 238 + 10 ml, p = 0,047) and greater cardiac dyssynchrony detected by 3D Echo (SDI: 13 + 3% vs 9 + 3%, p = 0,005) and by TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). After logistic regression analysis, the best predictors of left ventricular reverse remodeling after CRT were the cardiac dyssynchrony indexes evaluated by TDI (twelve segments) and SDI, but SDI (SDI > 11%) was the only independent factor in the prediction of left ventricular reverse remodeling six months after CRT (sensitivity of 0,78 and specificity of 0,79). Conclusions: 3D Echo was effective in the detection of left ventricular reverse remodeling after CRT, by detecting the reduction in left ventricular volumes (LVDV, LVSV) and the increase in LVEF. SDI was the only independent predictor of LV reverse remodeling after CRT. Patients with larger LV volumes, and smaller LVEF were more prone to not respond six months after CRT. CRT improved Functional Class (NYHA) and quality of life evaluated by MLHFQ
112

Avaliação da qualidade de vida de portadores de marcapasso cardíaco artificial em Goiânia, Goiás / Quality of life of artificial cardiac pacemaker patient in Goiânia, Goiás

ZATTA, Laidilce Teles 14 April 2010 (has links)
Made available in DSpace on 2014-07-29T15:04:27Z (GMT). No. of bitstreams: 1 dissertacao Laidilce T Zatta.pdf: 353033 bytes, checksum: 50158c4aade92a4a9fe7e29429d42d86 (MD5) Previous issue date: 2010-04-14 / Health related quality of life includes social, emotional and physical well-being of individuals, the impact of some treatments used to control health problems and the individual's ability to lead his own life. One of these treatments currently used is a device called artificial pacemaker, and patients have reported changes in daily life after implantation, which may influence the quality of their lives. It is a descriptive exploratory study that aimed to evaluate the quality of life of cardiac pacemakers patients using a generic instrument- SF-36 ® (Medical Outcomes Study 36-Item Short-Form Health Survey) and other specific instrument - AQUAREL (Assessment of Quality of Life and Related Events). We interviewed 84 patients with permanent pacemaker after six or more months of implantation, and used two instruments to assess quality of life: SF-36 and AQUAREL. Respondents had an average age 59.9 years, 58.3% were female, catholic (70.2%), had completed elementary school (81%). They self-reported themselves as white (59.5%), they had a steady partner (69%) and monthly family income below two minimum wages (51.3%). The implantation time varied between one and 28 years (median three years), the principal cause was the Chagas disease (76.2%), 73.8% were with the first generator, the predominant type of stimulation was DDDR (67,9%) and they were functional class I (57.1%). The median scores for SF-36 dimensions were higher in Social Functioning (100.00) and Mental Health (68.00) dimensions; the lowest scores were obtained in Role Limitations Resulting from Physical Health (00.00) and Role Limitations Resulting from Emotional Problems (33.33) dimensions. The median scores of AQUAREL were 81.25 for Chest Discomfort, Arrhythmias (80.00) and 71.43 for Dyspnea. Cronbach's Alpha ranged between 0.916 and 0.688 for SF-36 dimensions and between 0.852 and 0.693 for AQUAREL, indicating good reliability of the instruments. It was observed that the perception of individuals facing the aspects analyzed in each dimension of SF-36 and AQUAREL is not homogeneous, being influenced by religion, gender, age, race, presence of children, work, income level, education, number of implants and the reason of the implant. The lower scores indicate which aspects need attention from the health team to contribute to the quality of life of these patients. / A qualidade de vida relacionada à saúde engloba, além dos aspectos sociais, emocionais e de bem-estar físico dos indivíduos, o impacto de alguns tratamentos empregados para controle de problemas de saúde e a habilidade do indivíduo de conduzir sua própria vida. Um dos tratamentos é o implante de marcapasso cardíaco artificial definitivo, cujos portadores relatam alterações na vida diária após o implante, que podem influenciar na qualidade de suas vidas. Trata-se de estudo descritivo exploratório, que objetivou avaliar a qualidade de vida dos portadores de marcapasso cardíaco artificial por meio de um instrumento genérico - SF-36® (Medical Outcomes Study 36-Item Short-Form Health Survey) e outro específico - AQUAREL (Assessment of Quality of Life and Related Events). Foram entrevistados 84 portadores de marcapasso cardíaco artificial definitivo após seis ou mais meses de implante. Os entrevistados tinham idade média de 59,9 anos, 58,3% eram do sexo feminino, católicos (70,2%), possuíam escolaridade fundamental incompleta (81%). Autodenominaram-se brancos (59,5%), possuíam companheiro fixo (69%) e renda mensal familiar inferior a dois salários mínimos (51,3%). O tempo de implante variou entre um e 28 anos (mediana três anos), a causa base foi a doença de Chagas (76,2%), 73,8% estavam com o 1º gerador, o tipo de estimulação predominante foi DDDR (67,9%) e pertenciam à classe funcional I (57,1%). As medianas dos escores do SF-36 foram maiores nas dimensões Aspectos Sociais (100,00) e Saúde Mental (68,00) e os menores escores foram obtidos em Aspectos Físicos (00,00) e Aspectos Emocionais (33,33). As medianas dos escores do AQUAREL foram 81,25 para Desconforto no Peito, 80,00 para Arritmias e 71,43 para Dispnéia ao Exercício. O alfa de Cronbach variou entre 0,916 e 0,688 para as dimensões do SF-36 e entre 0,852 e 0,693 para o AQUAREL, indicando boa confiabilidade dos instrumentos. Observou-se que a percepção dos indivíduos frente aos aspectos analisados em cada dimensão do SF-36 e AQUAREL não é homogênea, sendo influenciada pela religião, sexo, faixa etária, raça, presença ou não de filhos, trabalho, faixa de renda, escolaridade, número de implante e motivo do implante. Os menores escores indicam quais aspectos precisam de maior atenção por parte da equipe de saúde. Reforça-se a necessidade da atuação qualificada de uma equipe multiprofissional que acompanhe o portador de marcapasso, minimizando os fatores que possam estar interferindo na sua qualidade de vida.
113

"Estudo dos efeitos da estimulação atrial temporária na prevenção da fibrilação atrial no pós-operatório de cirurgia de revascularização do miocárdio com circulação extracorpórea" / Study the effect of temporary atrial pacing in prevention of atrial fibrillation after coronary artery bypass graft surgery

Vicente Avila Neto 12 June 2006 (has links)
Avaliamos os efeitos da estimulação atrial temporária na prevenção da fibrilação atrial no pós-operatório de revascularização do miocárdio com circulação extracorpórea e identificamos os fatores de risco para o aparecimento dessa arritmia. Estudamos 240 pacientes que ao término da cirurgia de revascularização miocárdica submeteram-se ao implante de eletrodos epicárdicos na parede lateral do átrio direito e no teto do átrio esquerdo e foram randomizados em grupo não estimulado, grupo com estímulo atrial direito e grupo com estímulo simultâneo nos átrios direito e esquerdo. Concluímos que a estimulação atrial temporária reduziu a incidência de fibrilação atrial pós-operatória e que a idade avançada e a não estimulação atrial foram fatores preditivos independentes para a ocorrência da arritmia / We studied the effects of temporary atrial pacing to prevent the atrial fibrillation after coronary artery bypass graft surgery and the risk factors to occurrence of this arrhytmia. We followed-up 240 patients after coronary artery bypass graft surgery who suffered temporary pacing atrial implantation at the end of operation. The patients were randomized into three groups according pacing stimulation into right atrial pacing, biatrial pacing and no stimulated patients. We concluded that the temporary atrial pacing reduced the incidence of postoperative atrial fibrillation. In addition older age was also a predictive factor of occurrence of atrial fibrillation
114

Teacher's Perceptions of Pacing Guides as a Tool to Teach Science: Case of Constrained Professionalism

Gardner, Grant E., Jones, Gail M., Robertson, Laura, Robert, Sarah 01 April 2014 (has links)
No description available.
115

Studium klinického vlivu různých forem srdeční resynchronizační terapie u pacientů s chronickým srdečním selháním / Studium of the clinical impact of different forms of cardiac resynchronisation therapy by patients with chronic heart failure

Burianová, Lucie January 2012 (has links)
Studium of the clinical impact of different forms of cardiac resynchronization therapy by patients with chronic heart failure MUDr. Lucie Burianová ABSTRACT: Introduction: Biventricular (BiV) pacing decreases mortality and improves quality of life of patients with severe heart failure. Haemodynamic and short time clinical studies suggest that isolated leftventricular pacing could have the same effect. Aims: Compare the effect of BiV and leftventricular pacing by subjects with dilated cardiomyopathy and severe heart failure with the attention to signs of dyssynchrony and remodelation of the left chamber. In methodical substudy compare the results of left chamber volumes and ejection fraction (EF LK) measured by CT angiography and 2-dimensional echocardiography with use of contrast agent (K-ECHO). Methods: Patients indicated for cardiac resynchronization therapy were randomized for either BiV or leftventricular pacing. After implantation of the device they were examinated clinically and by echocardiography every 3 months in the period of one year. Four years from the onset of the study the major adverse events in both groups were evaluated. The results of left chamber volumes and EF LK measured by K-ECHO and CT angiography were compared. Results: We enrolled 33 patients. We found clinical improvement in both...
116

ALTERATIONS IN MYOSIN AND MYOCYTE STRUCTURE IN AN EXTREMLY LONG TERM PACING MODEL OF CANINE DILATED CARDIOMYOPATHY

Fuller, Geraldine Anne 20 December 2002 (has links)
No description available.
117

The short term influence of right ventricular pacing burden on echocardiographic and spiroergometric parameters in patients with preserved left ventricular ejection fraction

Youssef, Akram, Pfluecke, Christian, Dawid, Maciej, Ibrahim, Karim, Günther, Michael, Kolschmann, Steffen, Richter, Utz, Francke, Alexander, Wunderlich, Carsten, Christoph, Marian 22 April 2024 (has links)
Background The incidence of worsened clinical outcome due to high right ventricular (RV) pacing burden in patients with preserved left ventricular function remains controversial. Objective To investigate the impact of RV pacing on several echocardiographic and spiroergometric parameters. Methods In 60 pacemaker patients with preserved left ventricular ejection fraction (LVEF) serial echocardiographies and spiroergometries were performed over a time course of 12 months. Additionally, in 48 patients retrospective echocardiographic analyses of the LV- and RV function were carried out up to 24 months after pacemaker implantation. Results The patients were divided into two groups: The high RV pacing burden group (hRVP: ≥ 40%) and the low RV pacing group (lRVP < 40%) according to the definitions in previous randomized MOST and DAVID trials. After a period of 12-month pacemaker therapy no changes to left ventricular end diastolic diameter (LVEDD), left ventricular end systolic diameter (LVESD), LVEF, E/A-ratio; E/E′-ratio and tricuspid annular plane systolic excursion (TAPSE) could be revealed, independently of the RV pacing burden. Additionally, after 24-month long term follow-up there were no differences in LVEF and TAPSE in both groups. Accordingly, no relevant changes of peak exercise capacity, ventilatory anaerobic threshold or maximal oxygen consumption could be demonstrated independently of the RV pacing. Conclusions In pacemaker patients with preserved LVEF the burden of RV pacing has no adverse influence on several echocardiographic and spiroergometric surrogate parameters of pacemaker-induced cardiomyopathy after a follow-up of 12 to 24 month. Despite this, screening for pacemaker induced cardiomyopathy should be performed especially in the presence of new heart failure symptoms.
118

Factors influencing health-related quality of life in patients with implantable cardioverter defibrillator. / CUHK electronic theses & dissertations collection

January 2013 (has links)
Wong, Mei Fung Florence. / Thesis (D.Nurs.)--Chinese University of Hong Kong, 2013. / Includes bibliographical references (leaves 178-208). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstract also in Chinese.
119

Predição do desempenho em 10 km por meio de variáveis metabólicas e mecânicas: influência do nível de desempenho e da potencialização pós-ativação

Del Rosso, Sebastián 28 February 2018 (has links)
Submitted by Sara Ribeiro (sara.ribeiro@ucb.br) on 2018-08-08T17:35:32Z No. of bitstreams: 1 SebastianDelRossoDissertacao2018.pdf: 1818866 bytes, checksum: 3274a8646557f8e415e970e9bbe7a015 (MD5) / Approved for entry into archive by Sara Ribeiro (sara.ribeiro@ucb.br) on 2018-08-08T17:35:47Z (GMT) No. of bitstreams: 1 SebastianDelRossoDissertacao2018.pdf: 1818866 bytes, checksum: 3274a8646557f8e415e970e9bbe7a015 (MD5) / Made available in DSpace on 2018-08-08T17:35:47Z (GMT). No. of bitstreams: 1 SebastianDelRossoDissertacao2018.pdf: 1818866 bytes, checksum: 3274a8646557f8e415e970e9bbe7a015 (MD5) Previous issue date: 2018-02-28 / The main goal of the present study was to identify the main determinants influencing and thus explaining pacing and performance during self-paced 10 km running time trial and develop prediction equations including metabolic/respiratory and neuromuscular variables. Twenty-seven well-trained runners (age = 26,4 ± 6,5 years, training experience = 7,4 ± 5,9 years, training volume = 89,1 ± 39,1 km·week-1, VO2max = 62,3 ± 4,5 mL·kg-1·min-1) completed three testing sessions: During the first session, body composition and mechanical variables (concentric peak velocity, PV; time to peak velocity, TPV; peak force, PF; and peak power, PP) in the half-squat (AG) and loaded squat jump (SSC) were measured. The second testing session was dedicated to assessing metabolic variables [VO2max, ventilatory thresholds (VT1 and VT2), cost of running (CR) and maximal speed (SMAX)] and vertical jump (CMJ) potentiation; while during the third session a 10 km self-paced time trial was carried out. Also, before and after (0, 3, 6, and 9 min) the 10 km, athletes completed 2 CMJ for measuring mechanical variables [eccentric displacement (DE), mean eccentric and concentric velocity (VME, VMC), eccentric and concentric peak velocity (PVE, PVC)]. Pacing was defined as the time (T10km) or speed (S10km) every 1000 m, and analysis of those factors influencing the 10 km performance was carried by means of hierarchic multiple regression, whit the inclusion of all available variables. In addition, regression analyses were performed to develop prediction equation for T10km. Cluster analyses were carried out to evaluate the effects of performance levels [high performance group, GAD; low performance group (GBD)] and jumping potentiation (potentiation group, GP; non-potentiation group, GNP). For the whole sample, the final model including SMAX, CR, o a AGVP, Δ3-Pre CMJPVE (m·s-1), HRmax (bpm) and SSCPF (N) was statistically significant; r2 = 0,91, F(6-26) = 35,64, P < 0,001, EES = 0,76, r2ADJUSTED = 0,89; while the prediction model included the following variables: SMAX, CR and AGVP [r2 = 0,75; F(3-26) = 22,52; P < 0,001; EES = 1,23]. For the performance groups, there were significant main simple effects for time [F(2-52) = 12,20, P<0,001), η2 = 0,32] and group [F(1-25) = 49,91; P<0,001, η2 = 0,66] and also differences in the explaining variables for T10km: GAD [SMAX; SSCPF, HRMEAN, CV10km e Post-0min CMJPVE, F(5-9) = 266,06; P <0,001; SSE = 0,09 min; r2ADJUSTED = 0,99]; GBD [VT2-%VO2max, Δ6-Pre CMJEPV, CR; F(4-18) = 33,16; P <0,001, EES = 0,045 min; r2ADJUSTED = 0,88]. Furthermore, different prediction equations were found for each group: GAD – [T10km (min) = 68,65 – (1,084 × SMAX) – (0,008 × SSCPF) + (0,083 × AGCARGA); r2 = 0,98]; GBD - T10km (min) = 44,75 – (1,05× SMAX) + (0,17×VT2-%VO2max) + (1,89 × CMJVME) – (0,061 × Age); r2 = 0,89]. For jump potentiation groups there were significant differences only in the last 400 m and RPE (GNP = 8,36 ± 1,6 vs. GP = 6,8 ± 1,7; P = 0,03). Also, jump potentiation correlated with the final 400 m time in the whole sample (r = -0.42; P = 0,031) and with RPE for the GAD group (r = -0,75; P = 0,032). In conclusion, the results of the present study suggest that mechanical factors are significant for endurance runners given that explain part of the variance in the T10km while allowed for performance prediction. Moreover, performance level appears to be related to neuromuscular differences influencing pacing whereas jump potentiation likely affects effort perception. / O objetivo do presente estudo foi analisar os diversos fatores que podem influenciar e por tanto explicar o desempenho em uma prova de corrida de 10 km assim como também em subsegmentos dos 10 km, e predizer desempenho a partir de variáveis metabólicas/respiratórias e neuromusculares. Para tal fim, 27 corredores bem treinados (idade = 26,4 ± 6,5 anos, experiência de treinamento = 7,4 ± 5,9 anos, volume de treinamento = 89,1 ± 39,1 km·semana-1, VO2max = 62,3 ± 4,5 mL·kg-1·min-1) completaram três sessões de avaliação: A primeira sessão foi dedicada à determinação das variáveis mecânicas (pico de velocidade concêntrica, PV; tempo até o pico de velocidade, TPV; pico de força, PF e pico de potência, PP) nos exercícios de médio agachamento (AG) e salto com sobrecarga (SSC) e das variáveis associadas à composição corporal; durante a segunda sessão se avaliaram variáveis metabólicas [VO2max, limiares ventilatórios (VT1, primer limiar ventilatório, VT2, segundo limiar ventilatório), custo energético da corrida (CR) e velocidade máxima (SMAX)] conjuntamente com a potencialização no salto vertical (CMJ); e durante a terceira sessão se registrou o desempenho em uma prova simulada de 10 km (T10km) com monitoramento continuo da velocidade (GPS) e da frequência cardíaca (FC). Antes e depois (0, 3, 6 e 9 min) dos 10 km os atletas completaram 2 saltos verticais (CMJ) para à avaliação das variáveis mecânicas associadas ao salto [deslocamento excêntrico (DE), velocidade média excêntrica e concêntrica (VME, VMC), pico de velocidade excêntrica e concêntrica (PVE, PVC)]. O ritmo de corrida foi definido como o tempo ou velocidade a cada 1000 m, e para as análises dos fatores implicados na variância do desempenho em 10 km foi realizada uma análise de regressão múltipla hierárquica utilizando todas as variáveis disponíveis. Além disso, análises de regressão foram completadas para determinar equações de predição do T10km com variáveis independentes das registradas durante a prova. Entanto que analises por conglomerados foram utilizados para analisar os efeitos do nível de desempenho (grupo de alto desempenho, GAD; grupo de baixo desempenho, GBD) e da potencialização do salto vertical (grupo que exibiu potencialização, GP; grupo que não potencializou, GNP). Para o total de 27 atletas o modelo final que incluiu a SMAX (km·h-1), a CR (mL·kg-1·m-1), o a AGVP (m·s-1), o Δ3-Pre CMJPVE (m·s-1), a FCmax (bpm) e a SSCPF (N) foi estatisticamente significativo; r2 = 0,91, F(6-26) = 35,64, P < 0,001, EES = 0,76, r2ajustado = 0,89. Por outra parte, o modelo para a predição do T10km, com variáveis independentes da prova de 10 km, incluiu a SMAX, o CR e AGVP [r2 = 0,75; F(3-26) = 22,52; P < 0,001; EES = 1,23]. As analises por grupo de desempenho indicaram efeitos principais do tempo (Tempos parciais, Laps) [F(2-52) = 12,20, P<0,001), η2 = 0,32] e do grupo [F(1-25) = 49,91; P<0,001, η2 = 0,66] assim como diferencias nas variáveis que explicaram a variância no T10km: para GAD [SMAX; SSCPF, FCMÉDIA, CV10km e Pós-0min CMJPVE, F(5-9) = 266,06; P <0,001; SSE = 0,09 min; r2AJUSTADO = 0,99]; GBD [VT2-%VO2max, o Δ6-Pre CMJEPV, CR; F(4-18) = 33,16; P <0,001, EES = 0,045 min; r2AJUSTADO = 0,88]. Adicionalmente, acharam-se equações diferentes para a predição do T10km em cada um dos grupos: GAD – [T10km (min) = 68,65 – (1,084 × SMAX) – (0,008 × SSCPF) + (0,083 × AGCARGA); r2 = 0,98]; GBD - T10km (min) = 44,75 – (1,05× SMAX) + (0,17×VT2-%VO2max) + (1,89 × CMJVME) – (0,061 × Idade); r2 = 0,89]. Enquanto aos grupos de potencialização, se acharam diferenças significativas entre os grupos na velocidade atingida só no segmento de 400 m finais e na PSE final (GNP = 8,36 ± 1,6 vs. GP = 6,8 ± 1,7; P = 0,03). Ademais, na amostra completa a potencialização correlacionou com o tempo nos 400 m finais (r = -0.42; P = 0,031) e no grupo GAD, correlacionou com a PSE (r = -0,75; P = 0,032). Em conclusão, os resultados deste estudo sugerem que as variáveis mecânicas são importantes para corredores de 10 km já que permitem explicar a variância e predizer o desempenho. Além disso, o nível de desempenho parece estar associado com diferencias neuromusculares que influenciam o ritmo de corrida, entanto que a potencialização do salto vertical parece afeitar sobre tudo a percepção do esforço.
120

Estudo prospectivo e randomizado de profilaxia antimicrobiana para procedimentos cirúrgicos em estimulação cardíaca artificial / Prospective and randomized trial of antibiotic prophylaxis for cardiac stimulation surgical procedures

Oliveira, Júlio César de 11 September 2007 (has links)
O objetivo desse estudo foi avaliar os efeitos da administração prévia de antibiótico na incidência de complicações infecciosas em procedimentos de estimulação cardíaca artificial. Os pacientes foram selecionados em um estudo duplo-cego e randomizado (1:1). Grupo I Cefazolina (1,0g dose única) versus grupo II placebo. O comitê de segurança interrompeu o estudo após a inclusão de 649 pacientes devido à diferença entre os grupos (group I 314; grupo II 335 pacientes) em favor do uso de antibiótico: 2 infectados (0,63%) versus 11 infectados no grupo placebo (3,28%); p=0,016. Marcadores identificados por análise univariada: não uso de antibiótico; procedimentos de implantes (versus trocas); hematoma pós-operatório e duração do procedimento. O não uso de antibiótico e hematoma pós-operatório foram significantes em análise multivariada / The objective of this study was to evaluate the effects of the previous venous antibiotic administration in the incidence of infectious complications in cardiac stimulation surgical procedures. Patients were selected in a double blind, randomized (1:1) trial. Group I Cefazolin (1,0g one dose) versus group II placebo. The security committee interrupted the trial after inclusion of 649 patients due to differences between groups (group I 314; group II 335 patients) in favor of the antibiotic arm: 2 infected patients (0,63%) versus 11 infected patients in the placebo arm (3,28%); p=0,016. Markers identified by univariate analysis: non-use of preventive antibiotic; implant procedures (versus replacement); post-operative haematoma and procedure duration. The non-use of antibiotic and the post-operative haematoma were independent predictors of infection in multivariate analysis

Page generated in 0.0432 seconds