• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 324
  • 7
  • Tagged with
  • 334
  • 334
  • 276
  • 275
  • 71
  • 71
  • 66
  • 64
  • 63
  • 57
  • 42
  • 40
  • 38
  • 37
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Viabilidade e importância da redução da emissão de clorofluorcarbonos (CFCS) por reciclagem e controle no uso / Feasibility and importance of reducing emissions of chlorofluorocarbons (CFCs) for recycling and control in use

Assunção, João Vicente de 06 July 1993 (has links)
Uma pesquisa de campo foi conduzida para verificar as condições reais de utilização de clorofluorcarbonos em sistemas de refrigeração e de condicionamento de ar. A pesquisa cobriu os setores de refrigeração de supermercados, ar condicionado de edifícios e oficinas de reparação e de manutenção de geladeiras, \"Freezers\" e condicionadores de ar compactos e automotivos. A região escolhida para a pesquisa está localizada no município de São Paulo, tendo uma superfície de 12,504 Km2. As seguintes conclusões principais resultaram deste estudo: Predomina o consumo do HCFC 22 nos usuários pesquisados; a reciclagem e a recuperação ocorrem em pequena escala na região estudada; os sistemas de condicionamento de ar automotivos são a fonte mais significativa de substâncias agressivas à camada de ozônio, nos usuários pesquisados; vazamentos ocorrem por práticas de serviço não adequadas; a utilização do CFC 11 para limpeza de circuitos reduz o ganho obtido em sistemas que empregam o HCFC 22; a manutenção preventiva mostrou ser eficaz tanto para reduzir o consumo de gás refrigerante, como para reduzir a substituição de peças e componentes; a reciclagem e a recuperação do gás refrigerante tem efeito positivo em relação à camada de ozônio, economiza recursos naturais, reduz o consumo de energia, os riscos ao meio ambiente e à saúde da comunidade em geral. Finalmente, são feitas recomendações para o estabelecimento de um programa efetivo de reciclagem e recuperação de gases refrigerantes. / A field study was performed for verifying the actual conditions of the use of chlorofluorcarbons in refrigeration and air conditioning systems. The study has covered the sectors of supermarket refrigeration, building air conditioning systems, and refrigerators freezers and compact and automobile air conditioning systems repair shops. The region chosen for this study is located in the city of Sao Paulo and it has an area of 12.504 km2. The following conclusions resulted from the study: There is a predominance of the of HCFC 22 in the systems surveyied; recycling and recuperation are used in small scale in the region of the study; in the users covered by the study, the automobile air conditioning sector is the most important source of emission of ozone depleting substances; leaks occur because of bad service practices; the use of CFC 11 for circuit cleaning decreases the the gain obtained with the use of HCFC 22; the preventive maintenance has proved to be very efficient both for reducing the consum of refrigeration gases and for reducing the consum of parts and components of the refrigeration system; recycling and recuperation of refrigeration gases have positive effects in relation to the ozone layer, it saves natural resources, and reduces the risk to the enviromnent and to the public health. Finally, recommendations are made for the establishment of an effective refrigerant conservation program.
32

Viabilidade e importância da redução da emissão de clorofluorcarbonos (CFCS) por reciclagem e controle no uso / Feasibility and importance of reducing emissions of chlorofluorocarbons (CFCs) for recycling and control in use

João Vicente de Assunção 06 July 1993 (has links)
Uma pesquisa de campo foi conduzida para verificar as condições reais de utilização de clorofluorcarbonos em sistemas de refrigeração e de condicionamento de ar. A pesquisa cobriu os setores de refrigeração de supermercados, ar condicionado de edifícios e oficinas de reparação e de manutenção de geladeiras, \"Freezers\" e condicionadores de ar compactos e automotivos. A região escolhida para a pesquisa está localizada no município de São Paulo, tendo uma superfície de 12,504 Km2. As seguintes conclusões principais resultaram deste estudo: Predomina o consumo do HCFC 22 nos usuários pesquisados; a reciclagem e a recuperação ocorrem em pequena escala na região estudada; os sistemas de condicionamento de ar automotivos são a fonte mais significativa de substâncias agressivas à camada de ozônio, nos usuários pesquisados; vazamentos ocorrem por práticas de serviço não adequadas; a utilização do CFC 11 para limpeza de circuitos reduz o ganho obtido em sistemas que empregam o HCFC 22; a manutenção preventiva mostrou ser eficaz tanto para reduzir o consumo de gás refrigerante, como para reduzir a substituição de peças e componentes; a reciclagem e a recuperação do gás refrigerante tem efeito positivo em relação à camada de ozônio, economiza recursos naturais, reduz o consumo de energia, os riscos ao meio ambiente e à saúde da comunidade em geral. Finalmente, são feitas recomendações para o estabelecimento de um programa efetivo de reciclagem e recuperação de gases refrigerantes. / A field study was performed for verifying the actual conditions of the use of chlorofluorcarbons in refrigeration and air conditioning systems. The study has covered the sectors of supermarket refrigeration, building air conditioning systems, and refrigerators freezers and compact and automobile air conditioning systems repair shops. The region chosen for this study is located in the city of Sao Paulo and it has an area of 12.504 km2. The following conclusions resulted from the study: There is a predominance of the of HCFC 22 in the systems surveyied; recycling and recuperation are used in small scale in the region of the study; in the users covered by the study, the automobile air conditioning sector is the most important source of emission of ozone depleting substances; leaks occur because of bad service practices; the use of CFC 11 for circuit cleaning decreases the the gain obtained with the use of HCFC 22; the preventive maintenance has proved to be very efficient both for reducing the consum of refrigeration gases and for reducing the consum of parts and components of the refrigeration system; recycling and recuperation of refrigeration gases have positive effects in relation to the ozone layer, it saves natural resources, and reduces the risk to the enviromnent and to the public health. Finally, recommendations are made for the establishment of an effective refrigerant conservation program.
33

Levantamento das principais fontes de emissões atmosféricas na cidade de Manaus

Gomes, Edson Pinheiro 09 April 2009 (has links)
Submitted by Elaine Lucia (lucia.elaine@live.com) on 2015-06-30T18:57:27Z No. of bitstreams: 1 Dissertação - Edson Pinheiro Gomes.pdf: 12347358 bytes, checksum: 2db06179cb92fda9fad72e50d6fc95e4 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-07-01T15:13:30Z (GMT) No. of bitstreams: 1 Dissertação - Edson Pinheiro Gomes.pdf: 12347358 bytes, checksum: 2db06179cb92fda9fad72e50d6fc95e4 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-07-01T15:21:41Z (GMT) No. of bitstreams: 1 Dissertação - Edson Pinheiro Gomes.pdf: 12347358 bytes, checksum: 2db06179cb92fda9fad72e50d6fc95e4 (MD5) / Made available in DSpace on 2015-07-01T15:21:41Z (GMT). No. of bitstreams: 1 Dissertação - Edson Pinheiro Gomes.pdf: 12347358 bytes, checksum: 2db06179cb92fda9fad72e50d6fc95e4 (MD5) Previous issue date: 2009-04-09 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / There is a growinglack for effective action to obtain an air quality improvement, especially in urban areas where air pollution has become one of the factors that affect the quality of life. The assessment of air quality involves the measurement of its quality and identifies the main sources that cause pollution. In the present work was done the survey the main generating sources of air pollutants in the urban area of Manaus, to support actions such as the preparation of the inventory of emissions, monitoring of air quality and control of the generating activities. Currently, in the city of Manaus are found many sources of atmospheric emission. The mobile sources are probably the most significant because the progressive growthofthe vehicular fleet,makingit necessary to implement the Pollution Control Program of from Vehicles in Use - PCPV and Inspection and Maintenance Program of Vehicles in Use - I / M, for the control of vehicular emissions. In the particular industrial emissions case, the practice has been the pollution sources control in the licensing or monitoring process. However, this action is insufficient to comply with the law. In this work is recommended to carryout the emissions inventoryto establish a net work for monitoring air quality. This action would be to contribute for a more effective activities control to air pollution in thecity. / Há uma crescente necessidade de ações efetivas para obtenção de uma melhoria na qualidade do ar ambiente, principalmente nos centros urbanos, onde a poluição do ar tornou-se um dos fatores que mais afetam a qualidade de vida da população. A avaliação da qualidade do ar envolve não somente a medição de sua qualidade, como também a identificação das principais fontes que causam a poluição. No presente trabalho foi realizado o levantamento das principais fontes geradoras de poluentes atmosféricos na área urbana de Manaus, para subsidiar ações como, a elaboração do inventário das emissões atmosféricas, o monitoramento da qualidade do ar e o controle das atividades geradoras. Atualmente, existe na cidade de Manaus uma grande diversidade de fontes de emissões atmosféricas, sendo as fontes móveis, provavelmente as mais significativas, pelo crescimento progressivo da frota veicular,fazendo se necessário a implementação do Plano de Controle da Poluição por Veículos em Uso PCPV e do Programa de Inspeção e Manutenção de Veículos em Uso – I/M, para o controle das emissões veiculares. No caso particular das emissões industriais, a prática tem sido o controle por fontes poluidoras, seja na fase de licenciamento ou na fiscalização. No entanto, esta ação não tem sido suficiente para atender o que a legislação estabelece. Neste trabalho, recomenda-se que seja realizado o inventário de emissões, a fim de estabelecer uma rede de monitoramento da qualidade do ar, para que haja um controle mais efetivo das atividades que contribuem para a poluição do ar na cidade.
34

Estudo dos efeitos mutagênicos da poluição ambiental em trabalhadores de rua em São Paulo / Air pollution significantly influences mutagenesis in the oral mucosa: a study in inhabitants of Sao Paulo, Brazil

Negri, Ariadini 23 October 2009 (has links)
A poluição atmosférica vem recebendo crescente atenção como problema de saúde pública, pois representa uma fonte de agentes que podem promover o stress oxidativo e danos ao DNA, levando a efeitos cancerígenos e mutagênicos. As vias aéreas superiores, incluindo a cavidade oral são as áreas mais expostas do sistema respiratório, a material particulado e gases, e podem ser facilmente acessadas para monitorar a exposição humana a estes agentes. Nosso objetivo foi analisar o impacto da poluição do ar sobre a incidência de mutagénese em habitantes de nossa cidade. Para o estudo da mutagênese, utilizamos o teste de micronucleous (Mn), em células do epitélio da mucosa oral. Uma média de 4 a 6 amostras foram coletadas de cada voluntário, que concordou em participar do estudo, em São Paulo (SP) (n = 39) e, em Peruibe (PER), uma pequena cidade à beira-mar (n = 24), utilizados como um grupo controle. Os níveis de material particulado (PM10) foram medidos pelo método gravimétrico, e o ozônio e NO2 foram medidos pelos amostradores passivos, bem como pelas medições realizadas pela CETESB no mesmo local da coleta. Os resultados expostos em relação à concentração de MN / células, mostraram uma diferença estatisticamente significativa comparando SP (0042 ± 0032) e Per (0023 ± 0019), p = 0,009. Um aumento de MN / células foi observado em fumantes comparados aos não fumantes em SP (0055 ± 0012 e 0.040 ± 0005), p< 0,001 e em Per (0,0268 ± 0,00167 and 0,0181 ± 0,00128), p<0,001. Nosso estudo confirma os efeitos da poluição do ar na promoção de mutagênese e sugere possível sinergismo entre poluição e tabagismo / Air pollution is receiving crescent attention as a public health problem, as it represents a source of agents that may promote oxidative stress and DNA damage, leading to mutagenic and carcinogenic effects. The upper airways, including the oral cavity are the most exposed areas of the respiratory system to airborne particles and gases, and can be easily accessed to monitor human exposure to these agents. Our aim was to analyze the impact of air pollution on the incidence of mutagenesis in habitants of our city. To address mutagenicity, we used the micronucleous (mn) assay in desquamated cells of the oral mucosa. An average of 4 to 6 samples were collected from each subject that agreed to participate in the study in Sao Paulo (SP) (n=39) and in Peruibe (Per), a small city by the sea, (n=24) used as a control group. The levels of particulate (PM10) were measured by gravimetric methodology, ozone and NO2 were measured by passive monitors as well as by governmental monitoring stations in each location. The results exposed as mn/cells showed a statistically significant difference comparing SP (0,042 ± 0,032) and Per (0,023 ± 0,019), p= 0,009. An increase in mn/cells was observed in smokers compared to non smokers in SP (0,055 ± 0,012 and 0,040 ± 0,005), p<0,001 and in Peruíbe (0, 0268 ± 0,00167 and 0,0181 ± 0,00128), p<0,001. Our study confirms the hazardous effects of air pollution promoting mutagenesis and suggests that its effects may be synergic to smoking habit. We hope that our work may influence habits and public politics in order to improve public health in this issue
35

Poluição, internação e renda: uma abordagem  espacial no município de São José dos Campos / Pollution, hospitalization and income: a spatial approach in São José dos Campos

Mauro, Antonio Carlos Cortez 15 December 2014 (has links)
Introdução - São José dos Campos é um importante centro econômico e polo industrial, situado em uma região de vale e baixa dispersão atmosférica. Essas características são sugestivas de importante poluição do ar local, a qual pode afetar a saúde de populações mais vulneráveis, como a de idosos. Considerando que hospitalização de idosos pode estar relacionada também a fatores de risco, como a exposição à poluição em decorrência do local de moradia e à renda familiar, este trabalho propõe um estudo da distribuição espacial dos locais de habitação de idosos internados por doenças respiratórias e cardiovasculares, que podem ser associadas a processos da poluição do ar, verificando a existência de distribuição aleatória ou formação de agrupamentos e a correlação com a renda familiar predominante nos setores socioeconômicos do Município. Casuística e Métodos - Foi elaborado um banco de dados registrando os endereços, com coordenadas geográficas, de pacientes idosos internados por doenças cardiovasculares e respiratórias no Hospital Municipal de São José dos Campos, no ano de 2010. Foi realizada a espacialização desses endereços sobre o mapa da área urbana, bem como a espacialização da Taxa de Internação desses idosos sobre o mapa dos setores socioeconômicos do Município. Analisou-se a distribuição espacial da Taxa de Internação, utilizando-se estatística descritiva e Índice de Moran. Foi analisada a distribuição geográfica dos locais de habitação dos pacientes internados, aplicando-se o Estimador de Kernel. Resultados - Foram identificadas 1.200 internações de idosos por doenças respiratórias e cardiovasculares. O Índice de Moran, com base na divisão socioeconômica e taxas de internação do Município, não identificou agrupamentos de setores. Porém, a aplicação do Estimador de Kernel na espacialização dos locais de habitação permitiu a visualização de agrupamentos no entorno de importante autoestrada e fonte emissora de poluentes. Conclusões - A existência de agrupamentos de habitações de pacientes internados, próximos à principal rodovia que atravessa o Município, sugere correlação com a poluição por emissões veiculares. Não foram observadas evidências conclusivas sobre a correlação espacial entre taxa de internação e renda. O Inventário de Emissões de Poluentes Atmosféricos do Município, através da caracterização das fontes de poluição, corroborou a identificação de fatores de risco sanitário e ambiental / Introduction - São José dos Campos is an important economic and industrial hub center, located in a valley and region of low atmospheric dispersion. These features are suggestive of important local air pollution, which can affect the health of vulnerable populations such as the aged. Whereas hospitalization of the aged may also be related to risk factors such as exposure to pollution from the place of residence and family income, this thesis proposes a study of the spatial distribution of housing sites for aged patients hospitalized for respiratory and cardiovascular diseases which may be associated to air pollution processes, checking for random distribution or formation of clusters and the correlation with the predominant household income in socioeconomic sectors of the Municipality. Casuistry and Methods - A database was developed registering addresses with geographical coordinates of aged patients hospitalized for cardiovascular and respiratory diseases at São José dos Campos Municipal Hospital, in the year 2010. The spatial distribution of these addresses was performed on the map of the urban area as well as the spatial rate of hospitalization of the aged on the socio-economic sectors map of the Municipality. The spatial distribution of the hospitalization rate was analyzed, using descriptive statistics and the Moran\'s Index. The geographic distribution of housing sites of hospitalized patients was analyzed by applying the Kernel Estimator. Results - 1,200 hospitalizations of aged people were identified for respiratory and cardiovascular diseases. The Moran\'s Index, based on socioeconomic division and admission rates to the municipality, not identified groups of sectors. However, the application of Kernel Estimator for interpolation of local housing allowed the visualization of clusters around the major highway and emission source of pollutants. Conclusions - The existence of clusters of dwellings inpatients, near the main highway that runs through the municipality, suggests correlation with pollution from vehicle emissions. No conclusive evidence on the spatial correlation between hospitalization rate and income were observed. The Emission Inventory of Air Pollutants of the Municipality, through the characterization of pollution sources, corroborated the identification of health and environmental risk factors
36

Resposta molecular do endotélio pulmonar à exposição aguda de material particulado  fino / Molecular response of pulmonary endothelial cells to acute exposure to fine particulate matter

Alameddine, Mirna 03 March 2010 (has links)
Estudos epidemiológicos estabelecem uma associação evidente entre poluição do ar e o aumento de morbimortalidade cardiovascular e respiratória. No entanto, os mecanismos moleculares subjacentes aos efeitos do material particulado fino (MP2,5) sobre o organismo ainda estão pouco esclarecidos. O objetivo deste trabalho foi caracterizar o impacto da exposição ao MP2,5 sobre a biologia do endotélio pulmonar e do coração, através da avaliação do perfil de expressão gênica por microarray. Camundongos adultos fêmeas foram anestesiados e submetidos à instilação intratraqueal de MP2,5 (grupo exposto) ou veículo (grupo controle). Os animais foram sacrificados 12 a 18 horas após a instilação e pulmão, coração e sangue da veia cava inferior foram coletados. Os pulmões foram dissociados com colagenase tipo I e células endoteliais foram positivamente selecionadas por captura imuno-magnética através de micro-ímãs acoplados a anti-CD31. O cRNA derivado de endotélio pulmonar e de coração total foi hibridizado em membrana de microarray de baixa densidade desenhada para representar genes relevantes à biologia endotelial. Os genes encontrados diferencialmente expressos no pulmão foram Itgb1, Cxcl1, Tnf, Ecgf1 e Tnfaip3 (hiper-expressos em expostos a MP2,5) e Enpep, Pdgfra, Gzmb, Birc2, Npr1, Angpt1, Cxcl5 e Il7 (hipo-expressos). Não foi possível realizar análise de inferência estatística de membranas do coração neste trabalho. Não houve diferença estatisticamente significativa entre os grupos exposto e controle na contagem sangüínea de neutrófilos, linfócitos ou plaquetas, apesar dos dois grupos apresentarem plaquetose. Os achados indicam que MP2,5 altera a transcrição de genes envolvidos não só na inflamação e estresse oxidativo, mas também no tônus e remodelamento vascular, que podem ser os responsáveis pelos efeitos cardiovasculares agudos do MP2,5 / Epidemiological studies establish a clear association between air pollution and increased cardiovascular and respiratory morbidity and mortality. However, the molecular mechanisms underlying the effect of fine particulate matter (PM2,5) are still poorly understood. The aim of this study was to characterize the impact of exposure to PM2,5 on the biology of pulmonary endothelium and the heart, through the assessment of gene expression profiling by microarray. Adult female mice were anesthetized and submitted to intratracheal instillation of either PM2,5 (challenged group) or vehicle (control group). The animals were sacrificed 12 to 18 hours after instillation and lung, heart and blood samples from the inferior vena cava were collected. The lungs were dissociated with collagenase type I and endothelial cells were positively selected by immuno-magnetic capture through microbeads coupled to anti-CD31. The cRNA derived from the pulmonary endothelial cells and heart were hybridized to low-density microarray designed specifically to represent genes relevant to endothelial biology. Genes found differentially expressed in the lung were Itgb1, Cxcl1, Tnf, Ecgf1, and Tnfaip3 (over-expressed in challenged group) and Enpep, Pdgfra, Gzmb, Birc2, Npr1, Angpt1, Cxcl5 and IL7 (under-expressed). It was not possible to perform statistical inference of heart samples in this study. There was no statistically significant difference between challenged and control groups in blood counts of neutrophils, lymphocytes or platelets, despite both groups presented increased number of platelets. The findings indicate that PM2,5 alters transcription of genes involved not only in inflammation and oxidative stress, but also in vascular tonus and remodeling, which may be responsible for the acute cardiovascular effects of PM2,5
37

Análise da fonte e composição da poluição atmosférica em diferentes locais da região metropolitana de São Paulo / Analysis of source and composition of air pollution in different locations in the Metropolitan Region of São Paulo

Ramires, Letícia Ogushi Romeiro 10 January 2013 (has links)
Grandes cidades, como São Paulo, são afetadas de forma significante pela poluição atmosférica. É de grande importância a caracterização das fontes emissoras da poluição atmosférica, não somente nas regiões centrais, mas também nas regiões periféricas, pois a composição da poluição pode não ser homogênea em toda a extensão da cidade. Neste estudo foram caracterizados os componentes da poluição atmosférica em quatro regiões dentro cidade de São Paulo. Para este fim foram Coletados Material Particulado (PM2.5) durante vinte dias no período de inverno de 2011 e vinte dias durante o período de verão de 2011. O material foi coletado através de filtros de policarbonato com 24 h de exposição, e foi submetido a análises gravimétricas, determinação da concentração de Black Carbon por refletância e determinação da composição elementar por Fluorescência de Raios-X. A identificação das diferentes fontes geradoras de material particulado foi baseada na análise de Componentes Principais (ACP). A variação da concentração da massa do material particulado fino (PM2.5) em g/m3 não teve diferença significativa entre os locais amostrados, mas mostrou diferença entre as estações do ano, sendo maior no período do inverno em todos os locais. A proporção do Black Carbon teve um comportamento diferente da massa. O Black Carbon não variou significantemente entre as estações do ano, porém apresentou diferença entre os locais amostrados, destacando-se no Parque do Ibirapuera e na Zona Leste. Foram encontrados 3 Fatores que explicam 75% da variabilidade. O Fator 1 é constituído pelos elementos Ti, V, Mn, Fe, Ni, Pb, P, S Cr e K e foi atribuído como sendo associado à ressuspensão de solo e emissões veiculares, O Fator 2 é composto por V, P, BC, e S e foi interpretado como sendo representativo de emissões veiculares de combustíveis com alto teor de enxofre. O Fator 3 é 7 associado aos elementos BC e Ni e foi interpretado como sendo produzido por emissões veiculares em geral / Large cities such as São Paulo are significantly affected by air pollution. It is of great importance to characterize the emission sources of air pollution, not only in the central regions of the city of São Paulo, but also in peripheral regions, do to the fact that the composition of pollution may not be homogeneous across the city area. This study shows the Characterized the components of air pollution in four different areas of the metropolitan region of São Paulo. Particulate matter (PM 2.5) was collected during the winter of 2011 and summer of 2011. It was collected 24-h PM2.5 samples, employing gravimetry to determine PM2.5 mass concentrations; reflectance to quantify black carbon concentrations and X-ray fluorescence to characterize elemental composition. A receiver model based on principal component analysis (PCA) was used to identify the involvement of the different sources for the generation of particulate matter. The fine particulate matter (PM2.5) in g/m3 did not differ significantly among the locations. However, the results collected showed differences according the seasons evaluation, being higher in the winter for all regions sampled. The proportion of Black Carbon behaves differently than the mass. It does not vary significantly between the seasons, but between the different regions. The proportion of Black Carbon was higher in Ibirapuera Park and the East Zone. Was found 3 factors explaining 75% of the variability. Factor 1 consists of the elements Ti, V, Mn, Fe, Ni, Pb, P, S Cr e K and was related to crustal emission (soil) and vehicle emissions, Factors 2 consists of the elements V, P, BC, e S and can be related to vehicular emissions of fuels with high sulfur content. Factor 3 consists of the elements BC and Ni was associated to vehicle emission
38

Efeitos da adição de O2 puro sobre as emissões poluentes produzidas na incineração industrial de resíduos perigosos / not available

Sindicic, Daniel Ricardo 25 March 2002 (has links)
Estudou-se o efeito da adição de oxigênio puro ao processo de incineração de resíduos industriais perigosos como meio de reduzir emissões poluentes para a atmosfera. Deu-se ênfase especial à emissão de Material Particulado (MP) pois este é freqüentemente o fator limitante dos processos de incineração e o mais difícil de controlar. O trabalho experimental foi desenvolvido em uma unidade industrial com fornalha rotativa, câmara de pós combustão e sistema de tratamento de gases. Foram utilizados percentuais de oxigênio na vazão de oxidante do resíduo variando de 21% (ar atmosférico) até 55% (ar com adição de O2). Os resíduos de teste, sólidos e líquidos, foram materiais e misturas de materiais escolhidos por apresentarem diferentes propriedades físicas e químicas. Os teores de cloro destes materiais foram de até 26%, o de nitrogênio até 6,5%, a umidade até 33,5% e o poder calorífico inferior variou entre 13,6 e 50,5 MJ/kg. Sais metálicos foram adicionados em testes especiais destinados à detecção deste tipo de emissão. Os resultados mostraram, para a maioria dos casos, redução expressiva na emissão de particulados, no volume de escórias e na emissão de gases ácidos. O tempo de combustão de uma carga típica caiu para 1/3 daquele obtido como o uso de ar atmosférico apenas. Por outro lado a emissão de NOx subiu, mas não ultrapassou o limite estabelecido pela legislação. A operação com a mistura de alto teor de cloro (26%) e nitrogênio (6,5%) mostrou comportamento diferente das demais, produzindo aumento da emissão de MP e gases ácidos, e acentuando a emissão de NOx. A maior emissão de MP parece decorrente da operação do sistema de tratamento de gases e não do processo de incineração em si. Um modelo matemático baseado em rede neural foi desenvolvido para a previsão das emissões de MP e NOx, mostrando resultados razoáveis para o número de testes disponíveis, 27 ao todo. No geral o processo mostrou-se exequível e técnica, econômica e ambientalmente atraente. / The addition of pure oxygen to a process of incineration of industrial hazardous wastes was investigated as a mean to reduce atmospheric pollutants. Special attention was given to the emission of particulate matter (PM), once this is often the lirniting and most difficult factor to control in the incineration processes. The experimental work was developed in an industrial plant comprised by a rotary kiln incinerator equipped with a post combustion chamber and a gas treatment system. Oxygen percentage in the waste oxidant flow was varied from 21% (atmospheric air) to 55% (air plus pure O2). The wastes, liquid and solid, were materiaIs and mixtures of materials specifically chosen to present a range of physical and chemical properties. In them chlorine content were up to 26%, nitrogen up to 6.5%, humidity up to 33.5% and net calorific value from 13.6 to 50.5 MJ/kg. Metallic saIts were added in tests designed to detect this kind of emission. The resuIts show for the majority of the tests an expressive reduction in the emissions of PM, bottom ash, and acid gases. The combustion time of a typical load was decreased to 1/3 of its usual value (atmospheric air) when O2 was added. On the other hand, emissions of NOx have increased, although they remained bellow legislation limits. The operation with a mixture containing high levels of chlorine (26%) and nitrogen (6.5%) showed a different behavior increasing PM and acid gases emissions and accentuating the NOx emissions. The increase in PM seems to be a resuIt of the cleaning gas plant operational characteristics, rather than of the incineration process itself. A mathematical model based on neural networks was developed to predict PM and NOx emissions, showing reasonable agreement with experimental data for the 27 tests carried out. In general the process showed to be feasible and technical, economical end environmentally attractive.
39

Análise dos contaminantes biológicos presentes no material particulado (PM2,5) de amostras da região metropolitana de São Paulo / Analysis of biological contaminants in Particulate Matter (PM2.5) of Sao Paulo

Coelho, Cristiane Degobbi 05 August 2009 (has links)
INTRODUÇÃO: A poluição do ar traz diversos efeitos à saúde e, em particular, o material particulado menor do que 2,5 &#956;m (PM2,5), está associado ao aumento das taxas de morbidade e mortalidade devido a doenças cardiorespiratórias. A maioria dos estudos foca apenas na composição química do material, porém os componentes do bioaerossol podem ser responsáveis por aproximadamente 22% da massa total. OBJETIVOS: Nesse estudo, objetivamos determinar a contribuição relativa de fungos e endotoxinas (constituinte da parede celular de bactérias gram-negativas) no PM2,5 e verificar possíveis efeitos inflamatórios locais devido à exposição a fungos e PM2,5 em ratos. MÉTODOS: O estudo foi dividido em três partes: 1) comparação de metodologias de coleta de fungos em amostradores de ar de curta e longa duração realizada em ambiente externo e em ambiente de concentrador de partículas ambientais em Boston, MA. 2) Coleta de 4 tipos de filtros a partir de amostrador de ar de PM2,5 utilizados para análise separadamente de fungos, quantificação de endotoxinas, análise de elementos químicos e extração para instilação em ratos em São Paulo. Dados meteorológicos também foram coletados. 3) Instilação intratraqueal de PM2,5 e fungos originários da atmosfera de São Paulo em ratos machos Wistar divididos em 3 grupos: A (administração de 6,3x102 esporos/&#956;g de PM2.5), B (18x102 esporos/&#956;g de PM2.5) e C (controle - instilação a partir de extração de filtro branco). O sacrifício foi feito após 24 horas da exposição, depois da retirada do lavado broncoalveolar para contagem total e diferencial de leucócitos, além de quantificação de citocinas de respostas TH1 e TH2. RESULTADOS: O estudo de comparação de metodologias mostrou que, entre os amostradores de ar de curta duração, Personal Burkard recuperou maior diversidade e concentração do que Andersen (p<0,05). Entre os amostradores de longa duração, Recording Burkard mostrou-se o melhor em termos de diversidade e concentração de esporos do que filtros MCE (p<0,05). Também observamos que os fungos representaram relevante porção do PM2,5, chegando a concentrações de 2159 esporos/&#956;g em ambiente de Concentrador de Partículas alocado em Boston, MA. A segunda parte do estudo mostrou novamente que os fungos representam porção relevante do PM2.5 alcançando valores médios de até 1345 esporos/&#956;g de PM2,5 a partir de coletas da atmosfera de São Paulo. Da mesma forma, endotoxinas foram obtidas em concentrações médias de 5,52 EU/&#956;g de PM2,5. Os modelos de regressão linear múltipla mostraram que a contagem total de fungos, de basidiósporos hialinos e de Cladosporium sp foi correlacionada positivamente com a presença do fator Ba/Ca/Fe/Zn/K/Si no PM2,5 (p<0,05). Os gêneros Penicillium/Aspergillus foram correlacionados positivamente à concentração de material particulado na atmosfera (p<0,05). Os ascósporos sem pigmentação foram correlacionados positivamente à umidade (p<0,05). As endotoxinas foram correlacionadas apenas à temperatura atmosférica (p<0,05). O modelo de instilação em animais mostrou que a administração de 6,3x102 esporos/&#956;g de PM2,5 foi responsável por um aumento na concentração de TNF e IFN no lavado broncoalveolar (p<0,05). Não foi observado o mesmo efeito quando a concentração de esporos foi de 18x102 esporos/&#956;g de PM2,5. Não foram observadas diferenças sgnificativas contagem total e diferencial de leucócitos. CONCLUSÕES: Fungos e endotoxinas são responsáveis por fração relevante do PM2,5. Esses contaminantes biológicos podem estar associados não apenas a fatores meteorológicos, mas também a elementos químicos presentes no Material Particulado, especialmente a elementos sinalizadores de tráfego de veículos e ressuspensão da crosta. Exposições a diferentes concentrações de fungos associados ao PM2,5 em ratos não sensibilizados podem levar a diferenças em respostas inflamatórias agudas, porém os mecanismos responsáveis por tais resultados devem ser objeto de estudos futuros. / INTRODUCTION: It is well known that air pollution is associated with health effects, particularly, particulate matter (PM) is correlated with increment in morbity and mortality by cardiorespiratory diseases. A lot of studies have focused on chemical characterization of PM, although components of bioaerosols may comprise nearly 22% of the total mass. OBJECTIVES: The aims of this study were to determine the relative contribution of fungi and endotoxin (component of cell wall in gram-negative bacteria) in PM2.5 and verify acute local inflammatory response due to fungi and PM2.5 exposure in rats. METHODS: The study was divided in 3 parts: 1) Comparison among short and long term samplers located outdoor and in Ambient Particle Concentrator located in Boston, MA. 2) Sampling of 4 different filters types analyzed for fungi, endotoxin, chemical composition and extraction for instillation experiments in Sao Paulo. Meteorological data were also collected. 3) Intratracheal instillation of PM2.5 and fungi in male Wistar rats, divided in 3 groups: A (administration of 6.3x102 spores/&#956;g of PM2.5), B (administration of 18x102 spores/&#956;g of PM2.5) and C (control - blank filter). The animals were sacrificed 24 hours after exposure to collect bronchoalveolar lavage. Total and differential counts of leukocytes as TH1 and TH2 cytokines quantification were assessed. RESULTS: Sampling techniques comparisons showed that, the short term sampler Personal Burkard was able to collect more diversity and concentration of spores than Andersen sampler (p<0.05). The long term sampler Recording Burkard was also able to collect more diversity and concentration of spores than MCE filters (p<0.05). We also observed that fungi contribution to PM2.5 was relevant, representing up to 2159 spores/&#956;g of PM2.5 in Ambient Particle Concentrator located in Boston, MA. The second part of the study demonstrated again that fungi represent a relevant portion of PM2.5, reaching average values of 1,345 spores/&#956;g of PM2.5 in Sao Paulo atmosphere. Also, endotoxin concentrations reached averages values of 5.52 EU/&#956;g of PM2.5. Multiple linear regression models showed that total fungi counts, hyaline basidiospores and Cladosporium sp were correlated with factor Ba/Ca/Fe/Zn/K/Si (p<0.05). The genera Penicillium/Aspergillus were correlated with PM2.5 mass (p<0.05). Colorless ascospores were correlated with relative humidity (p<0.05). Endotoxin was correlated only with temperature (p<0.05). Instilattion results showed that administration of 6.3x102 spores/&#956;g of PM2.5 was responsible for an increase in TNF and IFN in bronchoalveolar lavage (p<0.05). The same pattern wasn\'t observed when 18x102 spores/&#956;g of PM2.5 was administered. No significant differences were observed leucocytes total and differential counts. CONCLUSIONS: Fungi and endotoxin represent a relevant fraction of PM2.5. These biological contaminants can be associated not only with meteorological parameters, but with elementary composition, especially elements of traffic and crustal ressuspension. Acute exposure of non sensitized rats to different concentrations of fungi associated to PM2.5 might trigger different inflammatory responses, although the specific mechanisms remain unknown and further research is needed.
40

Efeitos da poluição do ar na adrenal de camundongas: aspectos histomorfométricos e imunoistoquímicos / Effects of air pollution in the female mice adrenal. Histomorphometric and immunohistochemical aspects

Fuchs, Luiz Fernando Portugal 01 September 2014 (has links)
INTRODUÇÃO: A poluição em centros urbanos é produzida, principalmente, pela queima de combustíveis fósseis. Constitui problema que afeta a saúde da população, provocando doenças tanto no sistema respiratório, como sistemicamente em vários órgãos. Dentre as funções afetadas, realça o impacto da poluição sobre o sistema endócrino, podendo acometer as adrenais, tanto, no ser humano, como em roedores. Todavia, pouco se conhece sobre a ação nesta glândula. Assim, propusemo-nos a analisar os efeitos do ar poluído sobre as adrenais em duas gerações consecutivas de camundongas. OBJETIVOS: Analisar os efeitos do ar concentrado com material particulado (MP) 2,5um sobre as adrenais, avaliando as alterações histomorfométricas; a angiogênese pelo fator de crescimento vascular endotelial (VEGF-A); a pela proliferação celular por meio da proteína Ki-67 e o índice de apoptose pela caspase 3-clivada nas três zonas do córtex da adrenal. MATERIAL E MÉTODOS: Utilizaram-se 20 camundongas alocadas em biotério livre de poluentes, as quais foram acasalados na proporção de um macho para duas fêmeas. Após confirmação da cópula, foram divididas em 2 grupos de 10 animais cada. Acondicionou-se um grupo diariamente em uma câmara, onde as camundongas foram expostas a MP 2,5um à concentração de 600ug/m³ (G0P). O outro grupo, com 10 animais, foi alocado em outra câmara com ar filtrado (G0NP). A exposição ocorreu diariamente durante toda a prenhez das camundongas. Ao nascimento os conceptos, foram amamentados por 30 dias em amamentação, período onde não houve exposição aos poluentes. Após este período, as mães foram eutanasiadas para coleta das adrenais e as filhas sofreram o mesmo protocolo de exposição (G1P e G1NP - submetidas e não submetidas à poluição), não foram acasaladas, sendo eutanasiadas para coleta das adrenais ao fim do protocolo. As adrenais passaram por processamento histológico para coloração de H.E. e imunoistoquímico. RESULTADOS: As adrenais do grupo G0P apresentaram maior espessura da zona glomerulosa e as do G1P apresentaram maior quantidade de espongiócitos na zona fasciculada. As adrenais do grupo G1P tiveram maior imunoexpressão de VEGF-A na zona glomerulosa do que as do G1NP. A imunoexpressão do Ki-67 foi maior na zona reticulada no grupo G0P; no grupo G1P houve maior expressão do Ki-67 na zona glomerulosa do que no grupo G1NP. A imunoexpressão da caspase-3 clivada foi maior nos grupos G0P e G1P do que nos demais. CONCLUSÃO: A exposição ao ar poluído com material particulado 2.5?m determinou alterações histomorfométricas e imunoistoquímicas nas três zonas do córtex da adrenal de duas gerações consecutivas de camundongas. Estas alterações poderiam causar distúrbios endócrinos e cardiovasculares / INTRODUCTION: The pollution in urban centers is produced mainly by the burning of fossil fuels. It\'s a concern of public health, causing diseases in both the respiratory system and the other organs. Among the affected functions, it is important to highlight the impact of pollution on the endocrine system and this effect on the adrenal glands, both in humans and in rodents. However, little is known on the action of pollutants on this gland. Therefore, the aim of this study was to analyze the effects of polluted air on the adrenal in two consecutive generations of female mice. OBJECTIVES: To assess the effects of concentrate air with particulate matter (PM) 2.5um on the adrenal cortex evaluating histomorphometric changes; angiogenesis by vascular endothelial growth factor (VEGF-A); the cell proliferation by Ki-67 index and apoptosis by cleaved caspase-3 in the three zones of the adrenal cortex. MATERIAL AND METHODS: We used 20 female mice in their cages free of pollutants. Those animals were mated at a ratio of one male to two females. After mating confirmation, animals were divided into 2 groups of 10 animals each. A group was daily allocated in a chamber where the female mice were exposed to PM 2.5um at a concentration of 600ug/m³ (G0P). The other group of 10 animals was allocated in another chamber with filtered air (G0NP). The exposure occurred daily throughout pregnancy period. At birth, the fetuses were breastfed for 30 days. During breastfeeding period there was no pollutants exposure. After this period, mothers were euthanized for adrenal collection and daughters suffered the same exposure protocol (G1P and G1NP - exposed and not exposed to pollution), but those were not mated, being euthanized for adrenal collection at the end of the protocol. The adrenal underwent histological processing for H.E. staining and immunohistochemistry. RESULTS: The adrenal of the G0P group had increased thickness of the zona glomerulosa and the G1P presented more espongiocytes in the zona fasciculata. The adrenal of the G1P group had higher immunoreactivity of VEGF-A in the zona glomerulosa than one of the G1NP. The immunoreactivity of Ki-67 in the zona reticularis of G0P group was higher one of G0NP; there was a higher expression of Ki-67 in the zona glomerulosa of the G1P group compared to G1NP group. The immunoreactivity of cleaved caspase-3 in G0P and G1P was higher than ones of other groups. CONCLUSION: Exposure to air pollution with particulate matter 2.5um determined histomorphometric and immunohistochemical changes in the three adrenal cortical zones of the two consecutive generations of mice. These changes could cause endocrine and cardiovascular disorders

Page generated in 0.1042 seconds