• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 329
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 348
  • 348
  • 193
  • 90
  • 76
  • 68
  • 55
  • 48
  • 45
  • 41
  • 30
  • 26
  • 25
  • 24
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Sarcopenia em idosos: revisão, prevalência, concordância entre métodos diagnósticos e antropometria como proposta de rasatreamento / Sarcopenia in the elderly: review, prevalence, agreement between diagnostic methods and anthropometry as a screening proposition

Pagotto, Valéria 21 June 2013 (has links)
Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2014-12-01T16:58:26Z No. of bitstreams: 2 Tese - Valéria Pagotto - 2013.pdf: 1825466 bytes, checksum: f97e4cc29d226317b6a69fbcc4e88f19 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2014-12-04T14:32:55Z (GMT) No. of bitstreams: 2 Tese - Valéria Pagotto - 2013.pdf: 1825466 bytes, checksum: f97e4cc29d226317b6a69fbcc4e88f19 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-12-04T14:32:55Z (GMT). No. of bitstreams: 2 Tese - Valéria Pagotto - 2013.pdf: 1825466 bytes, checksum: f97e4cc29d226317b6a69fbcc4e88f19 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-06-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The aim of this study was to review methods and diagnostic criteria for sarcopenia available in the literature to estimate the prevalence and concordance between them, in a sample of elderly Goiânia, and propose anthropometry for screening sarcopenia. To review methods we used the recommendations for systematic review and meta-analysis of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement. For other purposes, we used a subsample of 132 elderly Senior Project/ Goiânia, selected in proportion to the Sanitation Districts of Goiânia. The data were collected by staff previously trained and standardized. Sarcopenia was analyzed by mass and muscle strength. The mass mucular was estimated by dual X-ray absorptiometry (DEXA), bioelectrical impedance analysis (BIA) and anthropometry, and muscle strength through hand grip strength (FPP). Analyses were performed in STATA 12.0, comparison of means and proportions, estimation of prevalence and prevalence ratio, Kappa, calculation of sensitivity and specificity analysis and ROC (receiver operator characteristic) curve. The project was approved by the Ethics Committee of the Federal University of Goiás. In 28 prevalence studies reviewed were found three methods for the diagnosis of sarcopenia: DEXA BIA and anthropometry with significant variations in prevalence as sex and the method adopted. Applying the diagnostic criteria found in the subsample Elderly Project/ Goiânia, the prevalence of sarcopenia ranged from 60.6% to 8.3% for the criteria of muscle mass and 54.2% to 48.8% for the strength, increasing in age and is more prevalent in men by criteria of muscle mass and women by criteria muscle strength. There was good agreement between two diagnostic criteria using DEXA, and moderate to weak for others. Anthropometric measurements of the circumference of the calf (CP), midlearm circumference (MAMC) and brachial circumference (CB) have been proposed for screenig sarcopenia and all showed good sensitivity and specificity for the cutoff of DEXA, and the CP had the best performance. We conclude that there are different methods and criteria for diagnosis of sarcopenia and its aplicabillity both in elderly sample of Goiânia, as other results in different prevalence rates by sex and age. The only good agreement between the two methods indicates DEXA both the need for an operational definition and the need for early detection. Anthropometric measurements of CP, CMB and CB can be used for tracking and consequent prevention of adverse events in elderly health resulting from sarcopenia / O objetivo deste estudo foi revisar os métodos e critérios diagnósticos de sarcopenia disponíveis na literatura, estimar a prevalência e a concordância entre estes diferentes critérios em amostra de idosos de Goiânia e propor o método antropométrico como rastreamento da sarcopenia. Para revisão de métodos foram utilizadas as recomendações para comunicação de estudos de revisão sistemática e metanálise do Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement. Para os demais objetivos utilizou-se subamostra de 132 idosos do Projeto Idosos/ Goiânia, selecionados de forma proporcional aos Distritos Sanitários de Goiânia. Os dados foram coletados por equipe previamente treinada e padronizada. A sarcopenia foi analisada segundo a massa e força muscular. A massa mucular foi estimada por meio da Absortometria por raio-X de dupla energia (DEXA), bioimpedância elétrica (BIA) e antropometria; e a força muscular por meio da Força de Preensão Palmar (FPP). As análises foram realizadas no STATA 12.0, por meio de testes para comparação de médias e proporções, estimativa da prevalência e razão de prevalência, teste Kappa, cálculo de sensibilidade e especificidade e análise de Curva Roc (receiver operator characteristic curve). O projeto foi aprovado pelo Comitê de Ética em Pesquisa da Universidade Federal de Goiás. Em 28 estudos de prevalência revisados, foram encontrados 3 métodos para diagnóstico de sarcopenia: DEXA, BIA e antropometria, com variações significantes na prevalência conforme o sexo e o método adotado. Aplicando os critérios diagnósticos encontrados na subamostra do Projeto Idosos/ Goiânia, a prevalência de sarcopenia variou de 60,6% a 8,3% para os critérios de massa muscular e de 54,2% a 48,8% para os de força, aumentando nas faixa etária, sendo mais prevalente em homens por critérios de massa muscular e em mulheres por critérios de força muscular. Observou-se boa concordância entre dois critérios diagnósticos utilizando DEXA, e moderada a fraca para os demais. As medidas antropométricas da Circunferência da Panturrilha (CP), Circunferência Muscular do Braço (CMB) e Circunferência Braquial (CB) foram propostas para rastreamento de sarcopenia e todas apresentaram boa sensibilidade e especificidade para os pontos de corte de DEXA, sendo que a CP teve o melhor desempenho. Conclui-se que existem diferentes métodos e critérios para diagnóstico da sarcopenia e a aplicabilidiade deles tanto na amostra de idosos de Goiânia, como em outras resulta em diferentes prevalências conforme sexo e faixa etária. A boa concordância entre apenas dois métodos de avaliação pela DEXA sinaliza tanto a necessidade de uma definição operacional como a necessidade de detecção precoce. As medidas antropométricas da CP, CMB e CB podem ser utilizadas para rastreamento e consequente prevenção de eventos adversos a saúde do idoso decorrente da sarcopenia.
292

AVALIAÃÃO DAS TENSÃES RESIDUAIS DE SOLDAGEM EM TUBULAÃÃES DE PEQUENO DIÃMETRO USADAS EM REFINARIA DE PETRÃLEO / Welding Residual Stress Evaluation of Small Size Pipes Used in Petroleum Refinering

Cleiton Carvalho Silva 16 January 2007 (has links)
AgÃncia Nacional do PetrÃleo / CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Este trabalho teve como objetivo avaliar o comportamento das tensÃes residuais em tubulaÃÃes de aÃo ASTM A106 Gr. B com pequeno diÃmetro, soldada pelos processos TIG manual e automÃtico. Buscou-se tambÃm avaliar o efeito do aporte tÃrmico sobre o perfil de tensÃes, bem como correlacionar os resultados com a microestrutura e dureza. A mediÃÃo das tensÃes foi realizada atravÃs de difraÃÃo de raio-X, utilizando um minidifratÃmetro empregado para mediÃÃo em campo. AnÃlises metalogrÃficas foram realizadas na seÃÃo transversal da junta, atravÃs de microscopia Ãtica e microscopia eletrÃnica de varredura. Foram levantados os perfis de microdureza nas superfÃcies externa e interna. Os resultados mostraram que a mediÃÃo de tensÃes residuais por difraÃÃo de raio-X, usando o minidifratÃmetro para aplicaÃÃes em campo, à eficaz na determinaÃÃo do perfil de tensÃes, contudo, à necessÃria a realizaÃÃo de ajustes dos difratogramas por funÃÃes analÃticas, para determinar a correta localizaÃÃo do pico de difraÃÃo de raio-X, reduzindo o erro das medidas. As mediÃÃes das tensÃes residuais axiais realizadas na superfÃcie externa dos tubos mostraram que o perfil à formado por tensÃes compressivas na regiÃo da solda (zona fundida e zona afetada pelo calor) e por tensÃes trativas nas regiÃes mais afastadas. Foram observados elevados nÃveis de tensÃes residuais axiais compressivas na superfÃcie externa de tubos de parede fina, na regiÃo da solda, os quais podem representar uma situaÃÃo crÃtica, visto que o comportamento linear das tensÃes ao longo da espessura devido ao efeito torniquete à consensual e, portanto, isso indica a presenÃa de elevados nÃveis de tensÃes residuais de traÃÃo no metal de solda e na zona afetada pelo calor. O ciclo tÃrmico do passe de acabamento ocasionou um intenso refino de grÃo e uma significativa reduÃÃo de dureza, especialmente no metal de solda e na superfÃcie interna dos tubos, a exceÃÃo das amostras de 2â de diÃmetro soldadas com elevado aporte tÃrmico. Nenhuma das amostras soldadas apresentou valores de dureza acima do mÃximo estabelecido por norma, que à de 248 HV, mostrando que o fato da junta apresentar dureza baixa, nÃo necessariamente representa que esta nÃo esteja sujeita a um elevado nÃvel de tensÃes residuais. / The aim of this work was to evaluate the behavior of welding residual stress in small size pipes of ASTM A106 Gr. B steel, welded by manual and automatic GTAW processes. It was also evaluated the effect of the welding heat input on residual stress profile, as well as to correlate the results with microstructure and hardness. The residual stress measurement was accomplished through X-ray diffraction, using a minidiffractometer for measurement in field. Metallographics analysis were accomplished in the traverse section of the welded joint, using optic microscopy and scanning electron microscopy. The microhardness profiles in the outer and inner surfaces of pipe were determined. The results showed that the measures of residual stress by X-ray diffraction with minidiffractometer for applications in field was shown quite effective in the residual stress profile determination, however, it is necessary the accomplishment of diffractograms fittings by analytic functions, to determine the correct peak localization, reducing the measures error. The measurements of the axial residual stress accomplished in the outer surface pipes showed that the profile is formed by compressive stresses in the welds region (fusion zone and heat affected zone - HAZ) and for tension stresses in the areas more distant of weld bead. High levels of compressive axial residual stress were observed in the outer surface of small size pipes, located in the welds region, which can represent a critical situation, because the linear behavior of the through-thickness residual stress due to âtourniquetâ effect is consensual and, therefore, indicates the presence of high levels of tension residual stress in the inner surface, especially in the root weld metal and HAZ. The welding heat input of the finish pass caused an intense grain refining and a significant reduction of hardness of the weld metal in the inner surface, exception of 2" diameter sample welded with high heat input. None of the welded samples presented values of hardness above the maximum established for standard, which is 248 HV, showing that the fact of the welded joint to present low hardness, it does not necessarily represent that this is not subject to a high level of residual stress.
293

Formación tardía de etringita en fibrocemento. / Delayed ettringite formation in fiber cement.

Felipe Jaime Davila 02 October 2015 (has links)
La temperatura de curado, utilizada por la industria de fibrocemento como catalizador en la hidratación del cemento para lograr alta resistencia inicial en sus productos, genera la hipótesis de expansión causada por formación tardía de etringita. Para el planteamiento de dicha hipótesis, el siguiente estudio contempló dos grupos de muestras con el objetivo de estudiar aisladamente su comportamiento químico y físico: uno de los grupos conformado por pasta cementicia con 35% de sustitución de calcario, y el otro conformado por fibrocemento con incorporación de PVA y celulosa. Por calorimetría isotérmica se observó la cinética de reacción de dos pastas, una de ellas curada a 23 ºC y la otra a 85 ºC donde esta última experimentó un efecto catalizador en sus reacciones. Ensayos de DRX y DTG/TG mostraron la presencia de etringita a 23 °C durante todas las edades de hidratación exhibiendo una tendencia de aumento en la intensidad de los picos y en la cantidad, respectivamente, en función del tiempo; sin embargo, a 85 ºC la presencia de esta fase fue inconstante durante las primeras edades de hidratación, a partir de mes de hidratación mostró aumento en cada una de las siguientes medidas realizadas mensualmente; a 85 °C hubo una menor formación de portlandita en comparación con los resultados obtenidos a 23 °C. Utilizando el método Rietveld y análisis químico fueron determinadas las cantidades y las composiciones químicas, respectivamente, de las fases del cemento anhidro y del calcario para alimentar el programa GEMS y simular la hidratación de la pasta estudiada en laboratorio para un tiempo infinito bajo la influencia de la temperatura. Simulaciones de la hidratación de la pasta se aproximaron a los resultados reportados por la revisión bibliográfica permitiendo predecir la presencia de fases en función de la estabilidad termodinámica. Resultados de porosimetría por inyección de mercurio mostraron una mayor concentración de poros, asociados a defectos, en muestras curadas a 85°C con respecto a las de 23 °C. Finalmente, medidas de variación longitudinal para muestras de fibrocemento elaboradas en laboratorio y en fábrica presentaron dispersión en los resultados de expansión para cada uno de los escenarios sin poder correlacionar todos los datos con el aumento de masa exhibido por cada una de las muestras; no obstante, se resalta el riesgo de deterioro del fibrocemento por el aumento de defectos causado por la temperatura así como la creación de todas las condiciones necesarias que favorecen la formación tardía de etringita a partir del proceso de fabricación empleado para este producto. / The curing temperature using by the fibercement industry as a catalyst in the hydration of cement, hypothesizes expansion caused by delayed ettringite formation. To approach this hypothesis, this study looked at two groups of samples in order to study its chemical and physical behavior individually. One group was composed of cement paste with 35% substitution of limestone filler, and the other by fibercement with addition of PVA and cellulose. In the isothermal calorimetry test was observed the kinetics reaction of both pastes, one cured at 23 °C and the other at 85 °C, the latter showed a catalytic effect in his reactions. XRD and DTG/TG showed the presence of ettringite at 23 °C for all hydration ages exhibiting a trend of increase in the peak intensity and amount, respectively in function of time, however, at 85 °C the presence of this phase was unstable during early ages of hydration until completing one month hydration where showed an increase in each of the following measurements monthly performed. At 85 °C there was a lower formation of portlandite when it was compared with results obtained at 23 °C. Using the Rietveld quantitative method analysis and chemical analysis were determined amounts and chemical compositions, respectively, of the phases of cement anhydrous and limestone filler to feed the GEMS software and simulate the hydration of paste studied in the laboratory for an infinite time under the influence of temperature. Simulations of paste hydration approached the reported data in literature allowing predicting the presence of phases according to thermodynamic stability. Additionally, results of mercury intrusion porosimetry showed a higher concentration of pores associated with defects, in samples cured at 85 ° C compared to 23 °. Finally, were taken measures of length offset of fibercement samples produced in laboratory and factory which had incorporation of PVA fibers and cellulose; they presented dispersion in the results of expansion for each of the scenarios unable to correlate with the mass gain exhibited by each sample. However, the risk of deterioration of the fibercement is highlighted by the increase of defects caused by temperature and the creation of all necessary conditions to favor the late formation of ettringite from the manufacturing process used for this product.
294

Avaliação da adaptação marginal e interna de coroas de dissilicato de lítio confeccionadas pelo sistema CAD/CAM após escaneamento direto e indireto / Evaluation of the marginal and internal adaptation of lithium disilicate crowns made by the CAD / CAM system after direct and indirect scanning

Bruna Neves de Freitas 15 December 2017 (has links)
O objetivo desse estudo foi avaliar a adaptação interna e marginal de coroas de dissilicato de lítio obtida por duas técnicas disponíveis pelo sistema CAD/CAM, o escaneamento direto e indireto. As análises foram realizadas por meio do microtomógrafo computadorizado (&microCT), microscópio confocal a laser (CL) e técnica da replica (TR), em dois momentos: antes e após a cristalização do material. O dente 14 de manequim foi preparado e duplicado em silicone, obtendo 20 réplicas em resina de poliuretano. Para a formação do Grupo 1 (IND/n=08), o manequim foi moldado com moldeira de estoque e silicone de adição com técnica de moldagem simultânea e modelagem com gesso pedra tipo III e IV, totalizando oito modelos em gesso. Os modelos foram escaneados com escâner indireto. Foram fresadas oito coroas de dissilicato de lítio. Para formação do Grupo 2 (DIR/n=08), o manequim foi escaneado com escâner direto. Oito imagens foram obtidas e enviadas ao laboratório pelo programa do sistema. Da mesma forma, foram fresadas oito coroas de dissilicato de lítio. As leituras da adaptação marginal das coroas foram realizadas com as mesmas adaptadas sobre a respectiva réplica em poliuretano, no &microCT, CL, e TR. As leituras da adaptação interna foram realizadas no &microCT e TR. As análises foram realizadas antes e após a cristalização das coroas. Os dados que apresentaram distribuição normal foram analisados por ANOVA dois fatores e os dados que não apresentaram distribuição normal foram analisados por teste U de Mann-Whitey para comparação entre os Grupos e pelo teste de Wilcoxon para comparação antes e após a cristalização. Em relação à adaptação axial, foi verificada diferença significante apenas para os Tempos (p=0,017), com menores valores após a cristalização. Para a adaptação interna não foi observada diferença entre os Grupos (p>0,05) ou Tempos estudados (p>0,05). Para a adaptação marginal vertical houve diferença para o Grupo IND, com maiores valores após a cristalização independente da metodologia de análise (&microCT - p=0,001; confocal - p=0,038). Já a medida marginal horizontal apresentou resultados divergentes de acordo com a metodologia utilizada. No &microCT, IND foi maior que DIR (p=0,003) e antes maior que após a cristalização (p<0,001). No confocal, IND menor que DIR após a cristalização (p=0,05), e para DIR, antes menor que após a cristalização (p=0,005). No volume total e volume marginal do espaço para cimentação houve diferença significante apenas para o DIR, com maiores valores após a cristalização (volume total - p=0,025; volume marginal - p=0,002). Pelos resultados obtidos pode-se concluir que há contração do material após a cristalização, resultando em maior desadaptação comprovado pelo aumento do volume total do espaço de cimentação em consequência da dificuldade de assentamento da coroa de dissilicato de lítio. / The objective of this study was to evaluate the internal and marginal adaptation of lithium desilicated crowns obtained by two alternative techniques to the CAD / CAM system, direct and indirect scanning. The analyzes were carried out by computerized microtomograph, laser confocal microscope and replica technique, in two moments: before and after the crystallization of the material. The manikin tooth 14 was prepared for total crown. Then it was duplicated, in silicone, and there were obtained 16 replicas in polyurethane resin. Two groups were formed from the impression of the manikin through the direct and indirect scanning, For the Group 1 (IND/n = 08), the manikin was molded with stock tray, with addition silicone, by the simultaneous molding technique and modeling performed with gypsum stone type III and IV, totaling eight molds and plaster models. The models were sent to the laboratory for scanning on the scanner indirect. Dissilicate crowns were made of lithium milled. For the Group 2 (DIR/n = 08), the dummy was scanned by scanner directly. The eight images obtained were sent directly to the laboratory by the system program. Likewise, milled lithium dissilicate crowns were made. The marginal adaptation of the crowns was performed with the same ones on the respective polyurethane tooth, in the computerized microtomograph (&microCT), confocal laser microscope (CL) and through the replica technique (TR). Internal adaptation readings were performed using a &microCT and TR. The analyses were made before and after the crystallization of the crowns. The data showed normal distribution were analyzed by two factors ANOVA and the data did not show normal distribution were analyzed for U Mann-Whitney test for comparison among groups and by the Wilcoxon test for comparison before and after the crystallization . In relation to the axial adaptation, significant difference was verified only for Times (p = 0.017), with lower values after crystallization. For the internal adaptation was not observed difference between groups (p > 0.05) or Times studied (p > 0.05). For the vertical marginal adaptation difference to the IND group, with higher values after the crystallization analysis methodology-independent (&microCT p = 0.001;-p = 0.038 confocal). Already the measure presented divergent results horizontal marginal according to the methodology used. In &microCT, IND was greater than DIR (p = 0.003) and greater than after the crystallization (p < 0.001). In confocal IND less than DIR after the crystallization (p = 0.05), and DIR, before less than after the crystallization (p = 0.005). In total volume and marginal volume of space for cementation significant difference only to the DIR, with higher values after the crystallization (total volume - p = 0.025; marginal volume - p = 0.002). The results obtained can be concluded that there is contraction of the material after the crystallization, resulting in higher leakage evidenced by the increase of the total volume of the cementing space as a result of the settling difficulty the dissilicate Crown.
295

Aplicação de potássio e sódio no crescimento e na qualidade do lenho de árvores de Eucalyptus grandis W. Hill ex Maiden / Application of potassium and sodium in the growth and quality of wood from Eucalyptus grandis W. Hill ex Maiden trees

Carlos Roberto Sette Junior 14 September 2010 (has links)
A diversificada e importante aplicação do lenho das plantações de eucalipto de rápido crescimento, com a aplicação de fertilização mineral, exigem a análise do seu efeito na qualidade do lenho. Com esse objetivo avaliou-se a dinâmica do incremento em diâmetro do tronco, as características anatômicas, físico-mecânicas e a concentração de nutrientes do lenho de árvores de Eucalyptus grandis, plantadas no espaçamento de 3x2 m e fertilizadas com potássio e sódio (no plantio, 6º, 12° mês). Foram selecionadas 60 árvores de eucalipto, no 22º mês, em 5 classes de área basal e avaliado o incremento em diâmetro do tronco, a cada 14 dias, de fevereiro de 2006 a fevereiro de 2010, através de dendrômetros. Para a amostragem do lenho em diferentes porcentagens da altura total do tronco foram selecionadas e cortadas árvores de eucalipto com a idade de 12, 24, 36 e 48 meses, em 5 classes de área basal. As amostras do lenho das árvores de eucalipto com 12, 24 e 36 meses foram utilizadas na avaliação das suas características anatômicas e determinação da densidade básica ponderada. Para as amostras do lenho das árvores de eucalipto com 48 meses foram analisadas as características anatômicas (fibras e vasos), físicas (densidade aparente e básica), mecânicas (resistência e rigidez à flexão estática e resistência a compressão paralela as fibras) nos tratamentos de fertilização, nas classes de área basal, nas posições radial e longitudinal do tronco e realizadas regressões múltiplas. Os resultados mostraram que as árvores de eucalipto dos tratamentos potássio e sódio e as de maior classe de área basal, apresentaram taxas de incremento do tronco superiores em relação às do tratamento controle e demais classes de área basal. Para o diâmetro do tronco das árvores foi detectado um efeito da sazonalidade climática, com períodos de máximo e mínimo crescimento. Houve diferença significativa entre os tratamentos de fertilização e classes de área basal das árvores para algumas características anatômicas e propriedades mecânicas; não foi observada diferença significativa para a densidade aparente e básica do lenho. Os maiores teores de potássio e de sódio foram encontrados no lenho das árvores dos respectivos tratamentos. A análise do teor de potássio e de sódio no lenho das árvores de eucalipto no 12º, 24º, 36º e 48º mês mostrou a maior retranslocação dos nutrientes nos respectivos tratamentos. Os resultados permitem concluir que os nutrientes, principalmente o potássio, induziu maior incremento em diâmetro e volume de lenho do tronco das árvores de eucalipto, sem alteração da sua densidade aparente e básica. A fertilização mineral influenciou algumas características anatômicas e propriedades mecânicas do lenho das árvores de eucalipto. O teor de potássio e de sódio variou nos tratamentos de fertilização, evidenciando a ocorrência de sua translocação no lenho das árvores ao longo da sua idade. / The diverse and important application of the wood in eucalyptus plantations of fast growth with the addition of mineral fertilizers, require the analysis of its effect on the woods quality. With this objective were evaluated the dynamics of the increment in trunk diameter, anatomical characteristics, physical-mechanical and nutrient concentration in Eucalyptus grandis trees planted at a spacing of 3x2 m and fertilized with potassium and sodium (at planting, 6, 12th month). Were selected 60 eucalyptus trees with 22 months, in five class of basal area and evaluated the increment in trunk diameter, every 14 days, from February 2006 to February 2010 through dendrometers bands. To sample the wood at different percentages of the total height of the trunk were selected and cut eucalyptus trees at the age of 12, 24, 36 and 48 months, in five class of basal area. The wood samples of eucalyptus trees with 12, 24 and 36 months were used in the evaluation of its anatomical and determination of the basic density. For eucalyptus trees wood samples with 48 months were analyzed the anatomic characteristics (fibers and vessels), physical (wood density), mechanical (strength and stiffness) in the treatment of fertilization, class of basal area, radial and longitudinal positions and multiple regressions. The results showed that the eucalyptus trees with the sodium and potassium treatments and the class of basal area upper had rates of growth upper than the control treatment and other class of basal area. For the trunk diameter of trees was detected a seasonal effect of climate, with periods of maximum and minimum growth. There were significant differences between fertilization treatments and class of basal area of trees to some anatomical characteristics, and mechanical properties; no difference was found for wood density. The higher concentration of potassium and sodium were found in trees of the respective treatments. The analysis of the content of potassium and sodium in the wood of the eucalyptus trees on the 12th, 24th, 36th and 48th months showed greater translocation of nutrients in the treatments. The results indicate that nutrients, particularly potassium, induced greater increase in volume and diameter of the eucalyptus trees trunk, without altering wood density. The mineral fertilization influenced some anatomical characteristics and mechanical properties of wood. The content of potassium and sodium varied in fertility treatments, indicating the occurrence of translocation in the wood of trees along its age.
296

Comportamento térmico de óxidos de ferro presentes em solos da savana de Roraima

José Lindolfo Carvalho Renda 29 October 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Nesse trabalho foi estudada uma seqüência de amostras de solos de acordo com os perfis; , com o objetivo de identificar através de análise difratométrica, óxidos de ferro, a partir do concentrado magnético induzido das amostras dos solos coletados em terras nas proximidades de Amajarí, Boa Vista, Bonfim e Alto Alegre em Roraima, visando fornecer subsídios para futuros projetos de uso do solo relacionados às áreas em que esses perfis estão localizados. Em uma primeira etapa as amostras foram coletadas em horizontes superficiais e subsuperficiais sendo definidos em 0,0 a 0,10 m; 0,60 a 1,00 m e 0,80 a 1,00 m e levadas ao laboratório de Manejo de Solos no Centro de Ciências Agrárias, onde procedemos ao tratamento e posterior afinamento das amostras de areia total (TFSA), e a separação do concentrado magnético. Na segunda etapa, as amostras tratadas foram levadas ao Laboratório de Propriedades Magnéticas no campus do Paricarana, onde foram feitas análises mineralógica utilizando a técnica de Difração de Raios-X / In this work was studied a soil sequence sample according to the profiles; and P_5, aiming to identify through analysis diffractogram, iron oxides, from the concentrated samples of induced magnetic soils collected on land near Amajarí, Boa Vista, Bonfim and Alto Alegre, Roraima, to provide data for future projects related to land use areas in which these profiles are located. In a first step the samples were collected in surface and subsurface horizons were defined in 0.0 to 0.10 m: 0.60 to 1.00 m and 0.80 to 1.00 I brought to the laboratory of Soil Management Center of Agricultural Sciences, where he proceeded to treatment and subsequent thinning of the sand samples total (TFSA), and the separation of the magnetic concentrate. In the second step, the treated samples were brought to the Laboratory of Magnetic Properties on the campus of Paricarana where mineralogical analysis was performed using the technique of X-ray diffraction
297

Estudo da estrutura da glândula pineal humana empregando métodos de microscopia de luz, microscopia eletrônica de varredura, microscopia de varredura por espectrometria de raio-X e difração de raio-X. / A study of human pineal gland structure, using optic microscopy, scanning eletron microscopy, x-ray spectrometry. scanning microscopy and x-ray difraction.

Sérgio Felipe de Oliveira 03 June 1998 (has links)
Estruturas da glândula pineal humana foram estudadas empregando os métodos de microscopia de luz, microscopia eletrônica de varredura, microscopia de varredura por espectrometria de raio-x e difração de raio-x. As peças para microscopia de luz foram fixadas em solução de formalina a 10% durante 48h e incluídas em parafina. Para a microscopia eletrônica de varredura, as peças foram fixadas em solução de Karnovsky modificada, sendo que parte das peças foram fraturadas em nitrogênio líquido para o exame das características internas do corpo píneal. Os resultados evidenciaram que o corpo píneal apresenta formações calcáreas distribuídas no interior do tecido conjuntivo. As formações calcáreas possuem tamanhos e formas diferentes. As estruturas calcáreas apresentam uma cápsula constituída pelo tecido conjuntivo. Na porção interna, a estrutura calcárea é constituída por uma série de !ameias concêntricas, com porosidade de aspecto amorfo. Evidenciou-se pela análise de difração de raio-x, a estrutura cristalina formada pelos átomos de vários elementos que compõem a formação calc área . / The structure of human pineal gland was studied by optic microscopy, scanning eletromicroscopy, spectrometer x-ray scanning eletron microscopy with energy dispersion (EDS). The tissues to analysis by optic microscopy were fixed in formalin at 1O % during 48 h and put in parffin. For S.E.M., the tissues were fixed in modified Kamovsky solution, and a part of the material was fracturated in liquid nitrogen to analysis of internal characteristic of the pineal body. The results showed that the pineal body has calcareon concretion distributed in the connective tissue. In the internai position, the calcareon structure was made of concentrics lamelae with amorf aspect. The x-ray difractor showed the cristalin structure of the atom arrangement of the elements that compose the calcarean concretions.
298

Panorama das exposições médicas em radiologia convencional no Estado de São Paulo / Overview of the medical exposures in coventional radiology in the State of São Paulo

Marcelo Baptista de Freitas 07 March 2005 (has links)
A dosimetria de pacientes associada à avaliação das condições de funcionamento dos equipamentos médicos e aos procedimentos empregados na realização dos exames, desempenha um papel fundamental no sistema de proteção radiológica das exposições médicas. Nesse sentido, foi realizado um levantamento em grande escala das doses recebidas pelos pacientes submetidos a exames radiológicos convencionais realizados em uma amostra representativa de estabelecimentos de saúde do estado de São Paulo. Nesse levantamento foi empregado um kit dosimétrico postal originalmente desenvolvido, que permitiu a determinação da dose de entrada na pele (DEP) através da técnica de dosimetria termoluminescente. Paralelamente foram realizadas visitas in-loco a uma sub-amostra de estabelecimentos, onde as condições de funcionamento dos equipamentos de raios X médicos e do sistema de imagem foram avaliadas empregando-se procedimentos e equipamentos já estabelecidos em protocolos de controle de qualidade. O estudo completou-se com a elaboração de um catálogo de espectros na faixa de energia do radiodiagnóstico, que, através de procedimento desenvolvido, permitiu inferir espectros equivalentes em equipamentos médicos. Na determinação dos espectros foi empregado um detector semicondutor de telureto de cádmio e zinco (CdZnTe), cujas curvas de eficiência e escape foram determinadas experimentalmente para realização do processo de correção dos espectros (stripping procedure). O processo de amostragem de estabelecimentos de saúde realizado neste estudo permitiu verificar a distribuição de equipamentos de diagnóstico por imagem e a freqüência de exames radiológicos no estado de São Paulo. A partir desses resultados foram escolhidos os exames de tórax, crânio (e seios da face) e coluna para avaliação de DEP, uma vez que os mesmos apresentam as maiores freqüências anuais de exames por 1.000 habitantes: 100, 46 e 29, respectivamente. Na técnica de amostragem dos estabelecimentos de saúde incluídos neste estudo foi empregado como critério de estratificação a quantidade anual de exames radiológicos associados ao município de localização do estabelecimento. Do total de 200 estabelecimentos sorteados, 50 participaram da primeira etapa e 38 da segunda. Um total de 83 salas de exames (ou equipamentos) e 868 pacientes foram incluídos, e um conjunto de 1415 valores de DEP foi determinado. O resultado da distribuição dos valores de DEP permitiu determinar os chamados níveis de referência, que, no caso de pacientes adultos, se mostraram bastante semelhantes aos encontrados em outros estudos internacionais. No caso de pacientes infantis, a situação é bem diferente, obtendo-se valores pelo menos 2 vezes superiores a outros recomendados internacionalmente para a radiografia infantil mais freqüente (tórax). Esse fato sugere que as práticas empregadas na realização dos exames devem ser revisadas e que recomendações específicas a esse grupo de pacientes, a partir de estudos dirigidos, sejam publicadas. Constatou-se também alguns casos de DEP elevada pelo uso desnecessário de radioscopia de localização. Os testes de desempenho dos equipamentos e a avaliação das imagens realizadas sugerem que há possibilidade de melhoria das condições de realização dos exames, sem perda de informação diagnóstica presente na imagem e com redução das doses. Alguns espectros de raios X determinados experimentalmente apresentaram divergência em relação a outros catálogos já estabelecidos, numa faixa específica de energia do espectro (entre 25 e 40 keV). Para a sua utilização em situações práticas há necessidade de algumas correções na curva de eficiência, o que não inviabiliza a metodologia e os procedimentos estabelecidos. De forma geral, os resultados encontrados neste estudo permitem traçar um panorama das exposições médicas em radiologia convencional no estado de São Paulo, contribuindo para o aperfeiçoamento de futuras pesquisas que sejam realizadas na área, ou mesmo, para a implementação de políticas públicas. / Patients dosimetry, associated with the assessment of the performance of the radiological equipment and of the series of procedures employed in the accomplishment of the examinations, plays fundamental role in the radiation protection system of medical exposures. Therefore, a large-scale survey of absorbed doses was carried out in health services localized in the state of São Paulo, including patients submitted to conventional radiological examinations. In this survey a postal dosimetric kit, originally developed, was employed. It allows the evaluation of the entrance surface dose (ESD) to patients with thermoluminescence dosimeters. Also a series visits to a sub-sample of services was carried out, giving rise to the in-loco evaluation of the performance of the medical x-ray equipment and of the image system, using procedures and equipments already established in protocols of quality control. The study is completed with the elaboration of a catalogue of x-ray spectra, which provides means to infer the spectra generated by medical x-ray equipments. Measurements of x-ray spectra were carried out with a cadmium zinc telluride detector (CdZnTe), and the stripping procedure was performed taking into account both the contributions of efficiency and x-ray escape fraction, experimentally determined in this work. The stratified sampling technique furnished important data on the distribution of equipments and the annual frequency of examinations performed in the state of São Paulo. From these results radiological examinations of the chest, skull and sinus, and spine were selected for the evaluation of ESD, as their annual frequencies are the highest observed: 100, 46 and 29 per thousand inhabitants, respectively. The number of x-ray examinations carried out annually in the cities of the state was employed as the stratification criterion to construct the sample. From a total of 200 health services sampled, 50 agreed to participate of the first stage, and 38 of the second. A total of 83 rooms (or x-ray equipments) and 868 patients was included, and a set of 1415 values of ESD was measured. Diagnostic reference levels were determined with the outcomes of the distribution of ESD. For adult patients, the reference levels achieved are very similar to others obtained in international surveys. However, as far as pediatric patients are concerned, the situation is very different: the values found in this survey are twice larger than the international recommendations to chest radiography of children. This points out that the practices need to be revised and that specific recommendations to this patient group, following specific surveys, should be provided. Also, a series of high ESD values due to unnecessary localizing radioscopy were detected among our data. The results of the equipment performance tests and of the evaluation of image quality suggest that it is possible to improve the conditions of the examinations and to reduce doses to patients, without impairment of the diagnostic information. Some of the experimentally determined x-ray spectra show a discrepancy, when compared to other catalogue spectra, in a particular energy range 25 to 40 keV. The practical application of them will require some corrections in the efficiency curve, but the established methodology and procedures remain legitimate. In an extensive approach, the results of this study supply a panorama of medical exposures in conventional radiology in the state of São Paulo, contributing with resources to future research in the field and also to governmental actions.
299

Avaliação comparativa entre os reparos das lesões agudas e crônicas do manguito rotador em estudo experimental / Comparative evaluation between acute and chronic rotator cuff tear repairs in an experimental model

Leonardo Muntada Cavinatto 03 February 2016 (has links)
Universidade de São Paulo, Faculdade de Medicina; 2015. Introdução: Diante de uma rotura traumática do manguito rotador, não há evidência direta que comprove que os reparos realizados precocemente são mais eficazes que aqueles realizados tardiamente. Para abordar essa questão, ensaios biomecânicos e de morfometria óssea foram realizados após roturas extensas do manguito rotador realizadas precocemente (lesões agudas) e tardiamente (lesões crônicas), mediante a utilização de um modelo experimental em ratos. Método: 30 ratos adultos da raça Wistar foram aleatoriamente divididos em três grupos (I, II e III) e submetidos à secção completa dos tendões do supraespinal e infraespinal nos ombros esquerdos. Após oito semanas, nos animais dos grupos I e II, os tendões rotos pertencentes aos ombros esquerdos foram cirurgicamente reparados, e os tendões equivalentes nos ombros direitos foram seccionados e imediatamente reparados. Quatro semanas após os reparos (para os ratos do grupo II) ou oito semanas após os reparos (para os ratos do grupo I), os animais foram submetidos à eutanásia. Os ratos do grupo III foram submetidos à eutanásia oito semanas após a cirurgia de secção tendínea sem que houvesse ocorrido o reparo dos tendões rotos. Os ombros direitos dos animais do grupo III permaneceram intactos e serviram como controles. Após a eutanásia, todos os ratos tiveram seus ombros dissecados e os espécimes foram encaminhados para a realização de testes biomecânicos e de microtomografia computadorizada. Resultados: Para todos os parâmetros biomecânicos analisados, foram encontradas interações significantes referentes aos fatores tempo de cicatrização e reparo, considerando os reparos precoces e tardios. Com relação ao tendão supraespinal para o período de oito semanas de cicatrização, a força máxima até a falha foi significantemente maior nos reparos precoces em comparação aos reparos tardios (31,81 ± 3,86N vs 19,36 ± 6,14N; p < 0,001), bem como a rigidez (17,22 ± 4,35N/mm vs 10,85 ± 4,25N/mm; p=0,034), a tensão máxima até a falha (4,49 ± 2,02N/mm2 vs 1,97 ± 0,61N/mm2; p < 0,001) e o módulo de elasticidade (13,72 ± 5,29N/mm2 vs 6,47 ± 2,42 N/mm2; p=0,033). Com relação ao tendão infraespinal com oito semanas de cicatrização, a força máxima até a falha foi significantemente maior nos reparos precoces em comparação aos reparos tardios (21,26 ± 3,94N vs 12,74 ± 2,87N; p=0,005), assim como a rigidez (12,86 ± 2,65N/mm vs 7,21 ± 3,30N/mm; p=0,014). O grupo com reparo tardio com oito semanas de cicatrização obteve resultados nos testes biomecânicos semelhantes aqueles obtidos nos testes do grupo com lesão sem reparo com oito semanas de cicatrização. A avaliação microtomográfica não apresentou diferenças significantes na microarquitetura óssea entre os reparos realizados precocemente e tardiamente. Conclusões: Os resultados desse estudo demonstram que as roturas extensas do manguito rotador reparadas precocemente produzem um tecido cicatricial na junção ósteo-tendínea com melhores propriedades biomecânicas que as roturas reparadas tardiamente. Porém, ao analisar a morfometria óssea da porção proximal do úmero, verificou-se que os efeitos são equivalentes, tanto para os reparos realizados tardiamente quanto para os reparos realizados precocemente / Introduction: In the event of a traumatic rotator cuff tear, there is no direct evidence that supports early over late surgical repair. To address this knowledge gap, biomechanical and bone morphometry outcomes were assessed following early (acute) and late (chronic) massive rotator cuff tear repairs in an experimental rat model. Methods: 30 adult Wistar rats were randomly divided into three groups (I, II and III), then subjected to combined supraspinatus and infraspinatus tendon tears of the left shoulder. Eight weeks following the injury, animals from groups I and II had the tendons of the injured shoulder surgically repaired. In addition, these animals were subjected to the same injury on the contralateral shoulder, which was immediately repaired. The rats were euthanized four weeks (group II) or eight weeks (group I) following the repairs. Group III was euthanized eight weeks following the injury, without surgical repair of the left shoulder, and the intact right shoulders of this group were used as controls. Tissues from all groups were harvested and subjected to biomechanical testing and bone morphometry analysis. Results: In all biomechanical parameters analyzed, a significant interaction was observed between healing and repair timing. For the supraspinatus tendon with eight weeks healing time, biomechanical properties were significant increased in the early repair group compared to the late repair group, including maximum load to failure (31,81 ± 3,86N vs 19,36 ± 6,14N; p < 0,001), stiffness (17,22 ± 4,35N/mm vs 10,85 ± 4,25N/mm; p=0,034), maximum stress to failure (4,49 ± 2,02N/mm2 vs 1,97 ± 0,61N/mm2; p < 0,001) and modulus of elasticity (13,72 ± 5,29N/mm2 vs 6,47 ± 2,42 N/mm2; p=0,033). For the infraspinatus tendon with eight weeks healing time, biomechanical properties were also significantly increased in the early repair group, including maximum load to failure (21,26 ± 3,94N vs 12,74 ± 2,87N; p=0,005) and stiffness (12,86 ± 2,65N/mm vs 7,21 ± 3,30N/mm; p=0,014). There were no significant differences between the late repair with eight weeks of healing time and the group without surgical repair for supraspinatus and infraspinatus tendons. Concerning bone morphometry of the humeral head, no significant differences were observed when comparing early and late repair groups. Conclusions: The results from this study indicate that early surgical repair of a massive rotator cuff tear leads to increased biomechanical properties of the tissue after healing. However, proximal humerus bone morphometry was unaffected by surgical repair timing
300

Estudo das propriedades magnéticas de nanopartículas de AuPd / Study of the magnetic properties of AuPd nanoparticles

Figueiredo, José Jadsom Sampaio de 11 July 2008 (has links)
Orientadores: Abner de Siervo e Flavio Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin. / Made available in DSpace on 2018-08-12T11:00:44Z (GMT). No. of bitstreams: 1 Figueiredo_JoseJadsomSampaiode_M.pdf: 4194889 bytes, checksum: 489e23ac30c4fa90808ef2de00ae46d4 (MD5) Previous issue date: 2008 / Resumo: Nanopartículas (NPs) metálicas, filmes ultrafinos e sistemas nano-estruturados têm motivado vários estudos teóricos e experimentais devido a novas propriedades eletrônicas, óticas e magnéticas destes materiais. Nas NPs, tais propriedades estão diretamente relacionadas aos efeitos de tamanho (size effect) e superfície, os quais afetam suas estruturas eletrônica e cristalográfica, concentrando um maior número de átomos na superfície em relação ao seu volume. Estudos recentes têm sugerido que alguns metais nobres sem nenhum tipo de ordenamento ferromagnético espontâneo podem apresentá-lo, mesmo a temperatura ambiente, quando segmentados em forma de nanopartículas. Exemplos desses metais são Au e Pd. Apesar dos esforços para provar a existência de comportamento ferromagnético nestes materiais, não existem medidas que demonstrem de forma não ambígua a polarização ferromagnética nos átomos de Pd. Na maioria dos trabalhos mostrados na literatura, o ferromagnetismo é quantificado por magnetometria SQUID. Faz-se necessário, portanto, verificar a existência de ferromagnetismo nestes materiais utilizando-se de técnicas elemento específicas, tais como XMCD (dicroísmo circular magnético de raios X). Esta técnica é muito importante para determinação quantitativa e seletiva dos momentos magnéticos de spin e orbital para cada elemento separadamente. O nosso trabalho se diferencia em relação a estes, pois ao invés de estudarmos cada elemento individualmente trabalhamos com nanopartículas do composto bimetálico Aux Pd1-x (x =0,00, 0,25, 0,50, 0,75) passivadas por tiol. Medidas de SQUID indicaram claramente um sinal magnético nestas nanopartículas, inclusive à temperatura ambiente. Neste trabalho apresentaremos os resultados preliminares da caracterização destas nanopartículas por medidas de SQUID, XANES, XPS, bem como XMCD nas bordas L2,3 do Pd e L3 do Au . Ressaltamos também, o desenvolvimento de uma instrumentação para medidas de XMCD em ambientes de UHV onde é possível submeter às amostras a altos campos magnéticos e condições de baixas temperaturas. Com base nos resultados obtidos discutiremos a possibilidade de ferromagnetismo nestas nanopartículas e sua origem. / Abstract: Metallic Nanoparticles (NP's), ultra-thin films and nano-structured systems have motivated several theoretical and experimental works because of their new electronic optical and magnetic properties of these materials. In NP's, such properties are directly related to the size and surface effects, which affect its electronic and crystallographic structures, by concentrating a larger number of atoms on the surface in relation to their volume. Recent studies have suggested that some noble metals without any kind of spontaneous ferromagnetic order can exhibit it, even at room temperature, when segmented as nanoparticles. Examples of these metals are Au and Pd. Despite the efforts to prove the existence of a ferromagnetic behavior in such materials, there are no measurements that demonstrate unambiguously the ferromagnetic polarization in Pd atoms, for example. Most of the works shown in the literature have used SQUID measurements to characterize the ferromagnetism in these materials. It is therefore necessary to verify the existence of ferromagnetism in these materials by using element specific techniques, such as XMCD (X-ray magnetic circular dichroism). XMCD is a very important technique, which is element selective and performs quantitative determination of the spin and orbital magnetic contributions for each element separately. Our work has a particular difference when compared to others in literature because instead of studying each element individually we have worked with NP's of the bimetallic compound Aux Pd1-x (x = 0.00, 0.25, 0.50, 0.75) capped by thiol. SQUID measurements clearly showed ferromagnetic behavior in these nanoparticles, even at room temperature. In this thesis we will present results of a systematic characterization of these nanoparticles by a multi-technique approach which involves measurements with SQUID, XANES, XPS and XMCD in the L2,3 edges of the Pd and Au L3 edge. We also emphasize the development of a new instrumentation for XMCD measurements at UHV where samples can be submitted to high magnetic fields and conditions of low temperatures. Based on these findings we discuss the possibility of ferromagnetism in these nanoparticles and its origin. / Mestrado / Física da Matéria Condensada / Mestre em Física

Page generated in 0.0674 seconds