• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 408
  • 9
  • 9
  • 9
  • 9
  • 8
  • 7
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 433
  • 349
  • 210
  • 91
  • 79
  • 74
  • 55
  • 48
  • 45
  • 41
  • 39
  • 38
  • 31
  • 31
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
421

Efeitos da manobra de recrutamento alveolar nas fases inspiratória e expiratória na tomografia computadorizada de tórax em pacientes com lesão pulmonar aguda ou síndrome do desconforto respiratório agudo / Effects of recruitment maneuver during expiration and inspiration analyzed by thoracic CT scan in patients with acute lung injury and acute respiratory distress syndrome

Matos, Gustavo Faissol Janot de 25 March 2008 (has links)
O objetivo da Estratégia de Recrutamento Máximo (ERM) guiada pela TC de tórax é minimizar a quantidade de colapso alveolar e os mecanismos de lesão induzida pela ventilação mecânica (VILI). Os objetivos deste trabalho são comparar por meio da análise quantitativa das imagens obtidas pela TC durante ERM, em pacientes com SDRA, os seguintes parâmetros: colapso, hiperdistensão Tidal Recruitment (TR), Tidal Stretch (TS) e a distribuição de ar nos pulmões Métodos - Doze pacientes foram transportados para a sala de TC e seqüências de imagens foram obtidas durante a pausa expiratória e inspiratória ao longo da ERM. A ERM consistiu em ventilação modo Pressão Controlada com diferencial fixo de pressão 15 cmH2O e elevações progressivas da PEEP de 10 - 45 cmH2O (fase de recrutamento) e titulação da PEEP (25 - 10 cmH2O) FR=10 - 15 irpm, relação I:E 1:1 e FiO2 1.0. Os pulmões foram divididos em quatro regiões de acordo com o eixo esterno - vertebral (1 anterior e 4 posterior) Resultados - A idade media da população estudada foi de 46 ± 20,5 anos e cerca de 92% dos pacientes tinham SDRA de origem primária. Com o objetivo de manter o recrutamento alcançado pela ERM foram necessários níveis elevados de PEEP média de 23,7 ± 2,3 cmH2O. A relação PaO2/FiO2 aumentou de 131,6 ± 37,6 para 335,9±58,7 (p<0,01) após a titulação da PEEP. A quantidade de colapso global diminuiu de 54 ± 8% (P10pré) para 4,8 ± 6% (P45) (p<0,01), e em P25pós foi mantido em níveis baixos 6,7 ± 6% (p=1,0). Em relação ao TR global, diminuiu de P10pre (4 ± 4%) para P45 (1 ± 1%) (p=0,029), e também foi mantido em níveis baixos após a titulação da PEEP em P25pós (p=1,0). Quanto à hiperdistensão, houve aumento estatisticamente significativo entre P10pré e P45 (p=0,032), embora em termos absolutos este aumento foi inferior a 5%. A comparação entre P25pré e P25pós revelou que não houve diferença entre eles (p=1,0). Não houve aumento do Tidal Hyperinflation entre P10pré e P45 (p=0,95). O Tidal Stretch também diminuiu durante a ERM e foi mantido em níveis baixos em P25pós, semelhantes aos observados em P45. Em P10pre durante pausa expiratória, quase 80% do ar se localizava distribuído na metade anterior dos pulmões. Durante ERM a distribuição de ar foi progressivamente em direção à metade posterior, até que em P25pós atingiu quase 40% (p<0,01). Discussão - A análise tomográfica detalhada destes 12 pacientes portadores de SDRA apresentou como principais resultados que a Estratégia de Recrutamento Máximo guiada por TC de tórax reduziu de forma significativa a quantidade de colapso pulmonar global, de Tidal Recruitment, de Tidal Stretch sem, no entanto, intensificar significativamente a geração de hiperdistensão. Foram necessários níveis elevados de PEEP (cerca de 25 cmH2O em média) para a manutenção do recrutamento adquirido e para garantir distribuição mais homogênea do ar nos pulmões. A elevação da PEEP de 10 cmH2O pra 20 cmH2O, sem a realização de manobra de recrutamento, pode exacerbar os mecanismos de VILI ao invés de diminuí-los. A ERM não promove aumento relevante da hiperdistensão, frente à imensa contribuição na redução do colapso e dos outros mecanismos de VILI. Conclusões - A ERM e titulação da PEEP guiados pela TC de tórax diminuiu significativamente a quantidade de colapso pulmonar, Tidal Recruitment e Tidal Stretch, sem no entanto, aumentar significativamente a hiperdistensão. A ERM também promoveu distribuição de ar mais homogênea no parênquima pulmonar. / The goal of Maximal Recruitment Strategy (MRS) guided by thoracic CT scan is to minimize alveolar collapse and the mechanisms of ventilator induced lung injury (VILI). The objectives of this study were to compare by quantitative analyzes of CT scan image of the lungs obtained during MRS of patients with ARDS, the following parameters: collapse, overdistension, Tidal Recruitment (TR), Tidal Stretch (TS) and the gas distribution throughout the lungs. Methods - Twelve patients were transported to the CT room and sequences of CT scan at expiratory and inspiratory pauses were performed during MRS. MRS consisted of 2 min steps of tidal ventilation with fixed deltaPCV=15 cmH2O and progressive increments in PEEP levels (recruitment 10 - 45 cmH2O) and PEEP titration (25 - 10 cmH2O). RR=10 - 15 bpm, I:E ratio 1:1, and FiO2 1.0. The lungs were divided in 4 regions according to the sternum-vertebral axis (1 anterior and 4 posterior). Results - The mean age of the studied population was 46 ± 20,5 y.o., and 92% of the patients ad primary ARDS. In order to sustain recruitment obtained by MRS, mean PEEP levels of 23,7 ± 2,3 cmH2O were necessary and PaO2/FiO2 ratio increased from 131,6 ± 37,6 to 335,9±58,7 (p<0,01) after MRS and PEEP titration. Global collapse decreased from 54 ± 8% (P10pre) to 4,8 ± 6% (P45) (p<0,01), and was sustained at similar levels at P25post 6,7 ± 6% (p=1,0). Global TR also decreased from P10pre (4 ± 4%) to P45 (1 ± 1%) (p=0,029), and was sustained with the same levels at P25post (p=1,0). Regarding overdistension there was statistically significant increment from P10pre to P45 (p=0,032), although in absolute terms the increment was very low < 5%, and P25pre and P25post were identical (p=1,0). There was no increment of Tidal Hyperinflation from P10pre to P45 (p=0,95). TS also decrease during MRS and was maintained at low levels similar to P45 at titrated PEEP (P25post). At P10pre almost 80% of the air at FRC was located at anterior regions. During MRS the distribution of air was directed towards the posterior regions and at P25post was almost 40% (p<0,01). Discussion - The tomographic analysis revealed that during MRS there was a significantly reduction of pulmonary collapse, Tidal Recruitment and Tidal Stretch, without increasing significantly overdistension. High levels of PEEP were necessary to sustain recruitment obtained during MRS and homogeneous gas distribution throughout the lung parenchyma. When PEEP was increased from P10pre to P20pre there was an increment in TR and TS, without a significantly reduction in absolute mass of collapsed lung, suggesting that it may exacerbate the mechanisms of VILI. MRS does not promote relevant overdistention when balanced by its effects on reduction of the mechanisms of VILI. Conclusions - MRS and PEEP titration guided by CT scan decreased significantly lung collapse, Tidal Recruitment and Tidal Stretch, without increasing significantly overdistension. MRS also promoted a homogeneous gas distribution throughout the lung parenchyma.
422

Composição corporal e antropometria de idosos:concordância entre métodos, desenvolvimento e validação de equações preditivas e pontos de corte / Body composition and anthropometry of the elderly:agreement between methods, development and validation of predictive equations and cutoffs.

BARBOSA, Larissa Silva 09 May 2011 (has links)
Made available in DSpace on 2014-07-29T15:25:15Z (GMT). No. of bitstreams: 1 Tese Larissa Silva Barbosa.pdf: 4706638 bytes, checksum: 84142955db2151a63ddb14705543d0e3 (MD5) Previous issue date: 2011-05-09 / The aim of this study was to assess body composition and anthropometry of the elderly with regard to agreement between methods, development and validation of predictive equations and cutoffs. We evaluated 132 elderly patients (52 men and 80 women) aged between 60 and 91 years, users of primary health care, not institutionalized and drawn at random in proportion to the nine health districts of Goiânia, GO. For collection of anthropometric measurements, bioelectrical impedance (BIA) and dual energy x-ray absorptiometry (DEXA), standardized procedures were used by trained examiners and equipment was calibrated regularly. Analyses were performed using STATA/SE. Descriptive analysis, tests for comparison of means, equation validation according to criteria suggested by Lohman, Bland-Altman and Lin graphic analysis and ROC (receiver operator characteristic curve) analysis were carried out. The project was approved by the Ethics Committee of the Federal University of Goias. The Durnin and Womersley equation showed the highest concordance correlation coefficient (CCC = 0.846) and the lowest mean differences (MD = - 2.335) for males. The equations of Lean et al. (for men) and Deurenberg et al. (for women) showed the highest correlation with and lowest mean differences from DEXA. Equations were proposed to estimate body fat percentage (BF%): (males: BF% = - 16.868 + 0.571TSF + 0.409WC and females: BF% = 8.634 + 0.601BMI + 0.321SISF + 0.234SSSF + 0.398TSF 0.467BSF). In both sexes, the equations are similar to DEXA in estimating BF% with high precision and accuracy. In males, the proposed body mass index (BMI) cutoff point was &#8805; 25 kg/m2; the waist circumference (WC) cutoff point was &#8805; 98.9 cm. In women, the BMI and WC values with the most sensitivity, specificity and accuracy were &#8805; 26.6 kg/m2 and &#8805; 90.5 cm. Since the currently available equations for predicting body composition of elderly have certain limitations, these newly developed and validated equations for the two sexes can be recommended for wide use. Accurate BMI and WC cutoff points for predicting BF% in older adults were also identified. / O objetivo deste estudo foi analisar a composição corporal e antropometria de idosos com relação à concordância entre métodos, desenvolvimento e validação de equações preditivas e pontos de corte. Foram avaliados 132 idosos (52 homens e 80 mulheres), com idade entre 60 e 91 anos, usuários da atenção primária à saúde, não instituicionalizados, selecionados a partir de sorteio aleatório proporcional aos nove distritos sanitários de Goiânia-GO. Para coleta de medidas antropométricas, impedância bioelétrica (BIA) e absortometria por raio-X de dupla energia (DEXA) foram utilizados procedimentos padronizados, por avaliadores devidamente treinados, com equipamentos regularmente calibrados. As análises foram realizadas no STATA/SE. Realizou-se análise descritiva, testes para comparação de médias, validação de equações segundo critérios sugeridos por Lohman, análise gráfica por Bland e Altman e por Lin e análise de Curva ROC (receiver operator characteristic curve). O projeto foi aprovado pelo Comitê de Ética em Pesquisa da Universidade Federal de Goiás. A equação de Durnin e Womersley apresentou maior coeficiente de correlação de concordância (CCC = 0,846) e menor diferenças médias (DM = - 2,335) para o sexo masculino. A equação de Lean et al. (para homens) e de Deurenberg et al. (para mulheres) apresentaram maior concordância e menores diferenças médias com DEXA. Foram propostas equações para estimativa do percentual de gordura corporal (%GC): (sexo masculino: %GC = - 16,868 + 0,571DCTR + 0,409CC e sexo feminino: %GC = 8,634 + 0,601IMC + 0,321DCSI + 0,234DCSE + 0,398DCTR 0,467DCBI). Em ambos os sexos, as equações propostas apresentaram semelhança com DEXA na estimativa do %GC, apresentando alta precisão e acurácia. No sexo masculino o ponto de corte proposto para índice de massa corporal (IMC) foi &#8805; 25 Kg/m2 e para circunferência da cintura (CC) &#8805; 98,9 cm. Nas mulheres os valores de IMC e CC com maior sensibilidade, especificidade e acurácia foram &#8805; 26,6 Kg/m2 e &#8805; 90,5 cm. As equações atualmentes disponíveis para predizer a composição corporal de idosos apresentam limitações, sendo desenvolvida e validada nova equação para ambos os sexos a qual recomenda-se sua ampla utilização. Identificou-se ainda pontos de corte acurados de IMC e CC para predizer %GC em idosos.
423

Efeitos da manobra de recrutamento alveolar nas fases inspiratória e expiratória na tomografia computadorizada de tórax em pacientes com lesão pulmonar aguda ou síndrome do desconforto respiratório agudo / Effects of recruitment maneuver during expiration and inspiration analyzed by thoracic CT scan in patients with acute lung injury and acute respiratory distress syndrome

Gustavo Faissol Janot de Matos 25 March 2008 (has links)
O objetivo da Estratégia de Recrutamento Máximo (ERM) guiada pela TC de tórax é minimizar a quantidade de colapso alveolar e os mecanismos de lesão induzida pela ventilação mecânica (VILI). Os objetivos deste trabalho são comparar por meio da análise quantitativa das imagens obtidas pela TC durante ERM, em pacientes com SDRA, os seguintes parâmetros: colapso, hiperdistensão Tidal Recruitment (TR), Tidal Stretch (TS) e a distribuição de ar nos pulmões Métodos - Doze pacientes foram transportados para a sala de TC e seqüências de imagens foram obtidas durante a pausa expiratória e inspiratória ao longo da ERM. A ERM consistiu em ventilação modo Pressão Controlada com diferencial fixo de pressão 15 cmH2O e elevações progressivas da PEEP de 10 - 45 cmH2O (fase de recrutamento) e titulação da PEEP (25 - 10 cmH2O) FR=10 - 15 irpm, relação I:E 1:1 e FiO2 1.0. Os pulmões foram divididos em quatro regiões de acordo com o eixo esterno - vertebral (1 anterior e 4 posterior) Resultados - A idade media da população estudada foi de 46 ± 20,5 anos e cerca de 92% dos pacientes tinham SDRA de origem primária. Com o objetivo de manter o recrutamento alcançado pela ERM foram necessários níveis elevados de PEEP média de 23,7 ± 2,3 cmH2O. A relação PaO2/FiO2 aumentou de 131,6 ± 37,6 para 335,9±58,7 (p<0,01) após a titulação da PEEP. A quantidade de colapso global diminuiu de 54 ± 8% (P10pré) para 4,8 ± 6% (P45) (p<0,01), e em P25pós foi mantido em níveis baixos 6,7 ± 6% (p=1,0). Em relação ao TR global, diminuiu de P10pre (4 ± 4%) para P45 (1 ± 1%) (p=0,029), e também foi mantido em níveis baixos após a titulação da PEEP em P25pós (p=1,0). Quanto à hiperdistensão, houve aumento estatisticamente significativo entre P10pré e P45 (p=0,032), embora em termos absolutos este aumento foi inferior a 5%. A comparação entre P25pré e P25pós revelou que não houve diferença entre eles (p=1,0). Não houve aumento do Tidal Hyperinflation entre P10pré e P45 (p=0,95). O Tidal Stretch também diminuiu durante a ERM e foi mantido em níveis baixos em P25pós, semelhantes aos observados em P45. Em P10pre durante pausa expiratória, quase 80% do ar se localizava distribuído na metade anterior dos pulmões. Durante ERM a distribuição de ar foi progressivamente em direção à metade posterior, até que em P25pós atingiu quase 40% (p<0,01). Discussão - A análise tomográfica detalhada destes 12 pacientes portadores de SDRA apresentou como principais resultados que a Estratégia de Recrutamento Máximo guiada por TC de tórax reduziu de forma significativa a quantidade de colapso pulmonar global, de Tidal Recruitment, de Tidal Stretch sem, no entanto, intensificar significativamente a geração de hiperdistensão. Foram necessários níveis elevados de PEEP (cerca de 25 cmH2O em média) para a manutenção do recrutamento adquirido e para garantir distribuição mais homogênea do ar nos pulmões. A elevação da PEEP de 10 cmH2O pra 20 cmH2O, sem a realização de manobra de recrutamento, pode exacerbar os mecanismos de VILI ao invés de diminuí-los. A ERM não promove aumento relevante da hiperdistensão, frente à imensa contribuição na redução do colapso e dos outros mecanismos de VILI. Conclusões - A ERM e titulação da PEEP guiados pela TC de tórax diminuiu significativamente a quantidade de colapso pulmonar, Tidal Recruitment e Tidal Stretch, sem no entanto, aumentar significativamente a hiperdistensão. A ERM também promoveu distribuição de ar mais homogênea no parênquima pulmonar. / The goal of Maximal Recruitment Strategy (MRS) guided by thoracic CT scan is to minimize alveolar collapse and the mechanisms of ventilator induced lung injury (VILI). The objectives of this study were to compare by quantitative analyzes of CT scan image of the lungs obtained during MRS of patients with ARDS, the following parameters: collapse, overdistension, Tidal Recruitment (TR), Tidal Stretch (TS) and the gas distribution throughout the lungs. Methods - Twelve patients were transported to the CT room and sequences of CT scan at expiratory and inspiratory pauses were performed during MRS. MRS consisted of 2 min steps of tidal ventilation with fixed deltaPCV=15 cmH2O and progressive increments in PEEP levels (recruitment 10 - 45 cmH2O) and PEEP titration (25 - 10 cmH2O). RR=10 - 15 bpm, I:E ratio 1:1, and FiO2 1.0. The lungs were divided in 4 regions according to the sternum-vertebral axis (1 anterior and 4 posterior). Results - The mean age of the studied population was 46 ± 20,5 y.o., and 92% of the patients ad primary ARDS. In order to sustain recruitment obtained by MRS, mean PEEP levels of 23,7 ± 2,3 cmH2O were necessary and PaO2/FiO2 ratio increased from 131,6 ± 37,6 to 335,9±58,7 (p<0,01) after MRS and PEEP titration. Global collapse decreased from 54 ± 8% (P10pre) to 4,8 ± 6% (P45) (p<0,01), and was sustained at similar levels at P25post 6,7 ± 6% (p=1,0). Global TR also decreased from P10pre (4 ± 4%) to P45 (1 ± 1%) (p=0,029), and was sustained with the same levels at P25post (p=1,0). Regarding overdistension there was statistically significant increment from P10pre to P45 (p=0,032), although in absolute terms the increment was very low < 5%, and P25pre and P25post were identical (p=1,0). There was no increment of Tidal Hyperinflation from P10pre to P45 (p=0,95). TS also decrease during MRS and was maintained at low levels similar to P45 at titrated PEEP (P25post). At P10pre almost 80% of the air at FRC was located at anterior regions. During MRS the distribution of air was directed towards the posterior regions and at P25post was almost 40% (p<0,01). Discussion - The tomographic analysis revealed that during MRS there was a significantly reduction of pulmonary collapse, Tidal Recruitment and Tidal Stretch, without increasing significantly overdistension. High levels of PEEP were necessary to sustain recruitment obtained during MRS and homogeneous gas distribution throughout the lung parenchyma. When PEEP was increased from P10pre to P20pre there was an increment in TR and TS, without a significantly reduction in absolute mass of collapsed lung, suggesting that it may exacerbate the mechanisms of VILI. MRS does not promote relevant overdistention when balanced by its effects on reduction of the mechanisms of VILI. Conclusions - MRS and PEEP titration guided by CT scan decreased significantly lung collapse, Tidal Recruitment and Tidal Stretch, without increasing significantly overdistension. MRS also promoted a homogeneous gas distribution throughout the lung parenchyma.
424

Legacy phosphorus in Brazilian agriculture and cover crops contribution to enhance this nutrient bioavailability in tropical Oxisols / Legado do fósforo na agricultura brasileira e a contribuição de plantas de cobertura para aumentar a biodisponibilidade deste nutriente em Latossolos

Marcos Rodrigues 20 February 2018 (has links)
Phosphorus (P) one of the essential elements to plants and animals, is a non-renewable resource and accuatlly high demanded in agriculture. The World\'s population growth and future estimatives on food demands raises the question about the sustainability of the current agriculture systems, speccially concerns about the low P use efficiency in agroecosystems. Brazilian agriculture requires high P inputs and many researches has been developed to increase the crops yield and, consequently, food production efficiency. However, this development was achieved at the high costs of mineral fertilisers (specially P) and long-term perspectives about the costs of the intensification in the tropical agriculture is accuattly in debate. In this conxtext, in the present thesis chapter two we evaluated the evolution of the Brazilian cropland basis and P demands, quantifying the Brazil P Legacy and, based on scenarios involving the cropland area and yield expansion, we estimated the future (up to 2050) Legacy P and P fertilisers demand. We also estimated the potential aleviation that could be achieved in the mineral fertilizers consumption by utilisation and improvements on manure P recycling. Alternatively, considering the systems intensification and its effects on P availability, we proposed alternative scenarios to promote the Legacy P utilisation in Brazil\'s improved agriculture systems to grant the agriculture expansion without huge increments on the national P fertilisers consumption. A worldwide recognized advance in Brazilian agriculture is the Cerrado, where large cropland areas accually are cultivated twice a year, improving the food and fiber production without any additional disturbance of natural ecossystems. In this context, no-tillage (NT) agriculture has been widely used and, as consequence, soil fertility has been improved, which could be also farorable to the P availability, when rotation with crop species with P mobilization mechanisms are introduced, such as cover crops utilisation. However, the effects of these improved rotated systems on P bioavailability in long-term in tropical soils remains uncert in the literature and was our objective in the chapter three, where is described a study envolving the evaluation of long-term changes on P fractions in tropical Oxisols, from two long-term field trials involving tillage systems (NT and conventional tillage, CT) and cover crops (millet, brachiaria, maize and control, fallow). The long-term cultivation generated large amounts of legacy P in the soil and with the brachiaria introduction as cover crop, more P was recycled in the topsoil and labile P and all the organic P fractions increased. Based on the cover crop effects, we proposed that the bioavailability of the legacy P could be represented by the P extracted by the labile fractions + moderately labile P fractions. In the chapter four, we used other techniques actually widely applied to P speciation, and we applied in tropical soils affected by the native Cerrado conversion into NT and CT agriculture. A multiple approach to identify and quantify the P forms in tropical soils were proposed by the utilisation of Hedley\'s fractionation togheter with P K-edge XANES for P-bindings into inorganic soil matrix and liquid 31P-NMR spectroscopy to complement the organic P species in tropical soils. / Fósforo (P), um dos elementos essenciais às plantas e animais, é um recurso não-renovável e altamente demandado na agricultura atualmente. O crescimento da população mundial e as estimativas futuras da demanda de alimentos aumentam os questionamentos sobre a sustentabilidade dos sistemas agrícolas atuais, especialmente no que se refere a baixa eficiência no uso do P na agricultura. A agricultura brasileira requer altas quantidades de P e muitas pesquisas tem sido desenvolvidas para aumentar a produtividades das culturas e, conseequentemente, a eficiencia da produção de alimentos. Entretanto, este desenvolvimento tem sido alcançado a altos custos com uso de fertilizantes minerais (sobretudo P) e as perspectivas de longo prazo sobre os custos da intensificação da agricultura tropical estão atualmente em debate. Nesse contexto, no capítulo dois da presente tese avaliamos a evolução da área cultivada no Brasil e das demandas de P, quantificando o legado do P no Brasil e, baseado em cenários envolvendo a expansão da área cultivada e da produtividade, estimamos o futuro (até 2050) legado de P e as demandas por fertilizantes fosfatados. Ainda estimamos a potencial redução no consumo de fertilizantes fosfatados que pode ser alcançada pela utilização e melhorias na reciclagem do P oriundo de dejetos. Alternativamente, considerando a intensificação dos sistemas e seus efeitos na disponibilidade de P, propusemos cenários alternativos visando a utilização do \"Legacy P\" em sistemas agrícolas melhorados para garantir a expansão agrícola sem drásticos incrementos no consumo nacional de fertilizantes fosfatados. Um avanço internacionalmente reconhecido na agricultura Brasileira é o Cerrado, onde extensas áreas agrícolas são cultivadas duas vezes ao ano, incrementando assim a produção de alimentos e fibras sem qualquer custo aos ecossistemas naturais. Nesse contexto, a agricultura sob plantio direto (PD) tem sido amplamente difundida e, como consequencia, a fertilidade dos solos tem-se elevado, o que pode também favorecer a disponibilidade de P, quando são introduzidas rotações com espécies de plantas que apresentam mecanismos de mobilização do P, como o uso de plantas de cobertura. Entretanto, os efeitos desses sistemas melhorados de rotação na biodisponibilidade de P em solos tropicais no longo prazo permanecem incertos na literatura e foram objeto de estudo no capítulo três, onde está descrito um estudo envolvendo a avaliação das mudanças de longo-prazo nas frações de P em Latossolos, oriundos de dois experimentos de campo de longa duração no Cerrado, envolvendo a avaliação de sistemas de preparo (PD e preparo convencional, PC) e plantas de cobertura (milheto, braquiária milho e um controle, apenas pousio). O cultivo por longo tempo resultou em grandes quantididades de \"Legacy P\" acumulado no solo e, com o uso de braquiária como cultura de cobertura, maior quantidade de P foi reciclado para as camadas superiores do solo e as frações de P lábil e todas as frações organicas aumentaram. Baseado nos efeitos das plantas de cobertura, sugerimos que a biodisponibilidade do \"Legacy P\" pode ser representada pelo P extraído nas frações lábeis + o P de frações moderadamente lábeis. No capítulo quatro, utilizamos outras técincas atualmente difundidas para a especiação de P, aplicando-as em solos tropicais influenciados pela conversão do Cerrado nativo em agricultura sob PD e PC. Uma abordagem múltipla para identificação e quantificação de formas de P em solos tropicais foi proposta através da utilização do fracionamento de P proposto por Hedley em conjunto com a especiação de P por XANES da borda K do P para identificação de ligação do P a matrix inorgânica do solo, e espectroscopia de ressonância magnética nuclear (NMR) para complementação da identificação de espécies orgânicas de P em solos tropicais.
425

Estudos dos efeitos das descargas atmosféricas nos índices de desempenho da subestação de Vila do Conde e subestação de Marabá

SANTOS, Luciano Silva dos 10 May 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-04-27T14:05:39Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudosEfeitosDescargas.pdf: 3450211 bytes, checksum: fca30650fac216b6df30f8e2dc05f5a8 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-05-04T12:57:18Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudosEfeitosDescargas.pdf: 3450211 bytes, checksum: fca30650fac216b6df30f8e2dc05f5a8 (MD5) / Made available in DSpace on 2017-05-04T12:57:18Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudosEfeitosDescargas.pdf: 3450211 bytes, checksum: fca30650fac216b6df30f8e2dc05f5a8 (MD5) Previous issue date: 2016-05-10 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Este trabalho tem como objetivo apresentar os efeitos de descargas atmosféricas nos índices de desempenho na subestação de Vila do Conde (SE VDC) e de Marabá (SE MB), onde estão situadas na região norte, no estado do Pará, integrando o Sistema Norte - Nordeste de Transmissão da ELETRONORTE, estando interligadas às Usinas Hidrelétrica de Tucuruí (UHE Tucuruí). Foram estudadas, estabelecendo as relações entre as informações meteorológicas cedidas pelo SIPAM e dados fornecidos pelo centro de operações da Eletronorte no período de 2005 a 2013 de forma a determinar os efeitos nocivos das descargas atmosféricas, as quais são responsáveis pela intensificação de interrupções no fornecimento de energia elétrica. A análise por restrita à área de atuação da Eletronorte SE VDC e SE MB. O estudo desenvolvido evidência os desligamentos por descargas atmosféricas na linha de transmissão VDC/CASTANHAL de 230 KV e no disjuntor de 500 KV VCDJ7-08 e linha de transmissão MB/Imperatriz de 500 KV. Os resultados demonstram que a incidência de um raio pode causar surtos diretos e indiretos em linhas de transmissão e subestações de alta potência. Neste contexto justifica o estudo de formas eficientes de prevenção, sendo uma das finalidades deste trabalho. / This paper aims to present the effects of lightning in the performance indices in Vila do Conde substation (SE VDC) and Maraba (SE MB), which are situated in the north, in the state of Pará, integrating the North System - Eletronorte Transmission northeast, being connected to the Tucuruí Hydroelectric Power Plants (HPP Tucuruí). They were studied, establishing relations between the weather information provided by the SIPAM and data provided by central Eletronorte's operations in the period 2005-2013 in order to determine the harmful effects of lightning, which are responsible for the intensification of supply interruptions electricity. The analysis restricted to the area of operation of Eletronorte SE and SE VDC MB. The study developed evidence disconnections by lightning on transmission line VDC / CASTANHAL 230 KV and 500 KV breaker VCDJ7-08 and transmission line MB / Empress of 500 KV. The results demonstrate that a lightning strike may cause direct and indirect surges in transmission lines and high power substations. In this context it justifies the study of efficient forms of prevention, one of the purposes of this work.
426

Medidas de concentração de radônio proveniente de argamassas de cimento portland, gesso e fosfogesso / Measurements of radon concentration from portland cement, gypsum and phosphogypsum mortars

Narloch, Danielle Cristine 14 September 2015 (has links)
CAPES / O cimento Portland é bastante empregado na construção civil e apresenta em sua composição o gesso natural. Para minimizar custos é possível substituir parte do gesso desta composição pelo fosfogesso. O fosfogesso é um resíduo gerado a partir da produção dos fertilizantes e é constituído, essencialmente, por cálcio dihidratado e algumas impurezas, como fluoretos, metais em geral e radionuclídeos. Atualmente, toneladas de fosfogesso são armazenadas à céu aberto próximo das indústrias de fertilizantes, causando a contaminação do meio ambiente. O elemento 226Ra, presente nesses materiais, ao passar pela série de decaimento radioativo, transforma-se em gás 222Rn. Esse gás, ao ser inalado pode decair dentro dos pulmões e neste caso, os seus produtos depositam-se nas paredes pulmonares ocasionando exposição à radiação, podendo ser um potencial causador de câncer pulmonar. Dessa forma, o objetivo desta pesquisa foi medir os níveis de concentração de 222Rn em corpos de prova de argamassa de cimento Portland, de gesso e de fosfogesso provenientes do Estado do Paraná, além de caracterizar o material e estimar a concentração de radônio em um ambiente de convívio humano hipotético construído com paredes destes materiais. Para as medidas de atividade do 222Rn foi utilizado o monitor AlphaGUARD (Saphymo GmbH). A análise qualitativa e quantitativa foi realizada por meio da espectrometria gama e da EDXRF com tubos de alvos de Au e Ag (AMPTEK), e com alvo de Mo (ARTAX) e os ensaios mecânicos com equipamento de raios X (Gilardoni) e com a prensa mecânica (EMIC). Os valores médios da atividade do radônio no ar obtidos pelo estudo dos materiais armazenados no recipiente foram de 854 ± 23 Bq/m3, 60,0 ± 7,2 Bq/m3 e 52,9 ± 5,4 Bq/m3 para argamassas de cimento Portland, de gesso e de fosfogesso, respectivamente. Estes resultados extrapolados para o ambiente hipotético de 36 m3 com paredes revestidas com os materiais foram de 3366 ± 91 Bq/m3, 237 ± 28 Bq/m3 e 208 ± 21 Bq/m3 para argamassas de cimento Portland, gesso e fosfogesso. Considerando o limite de 300 Bq/m3 estabelecido pela ICRP, observa-se que, para o revestimento de cimento Portland a exposição não é segura e requer alguns procedimentos de mitigação específicos. A partir da espectrometria gama foi calculado o valor do rádio equivalente (Raeq) para as argamassas de cimento Portland, gesso e fosfogesso que resultou em 78,2 ± 0,9 Bq/kg; 58,2 ± 0,9 Bq/kg e 68,2 ± 0,9 Bq/kg, respectivamente. Os valores do Raeq das amostras encontram-se inferiores ao limite máximo de 370 Bq/kg. Em relação a análise qualitativa e quantitativa das amostras por EDXRF, os resultados permitiram identificar e quantificar os elementos que compõe as amostras como o Ca, S, Fe, entre outros. / Portland cement being very common construction material has in its composition the natural gypsum. To decrease the costs of manufacturing, the cement industry is substituting the gypsum in its composition by small quantities of phosphogypsum, which is the residue generated by the production of fertilizers and consists essentially of calcium dihydrate and some impurities, such as fluoride, metals in general, and radionuclides. Currently, tons of phosphogypsum are stored in the open air near the fertilizer industries, causing contamination of the environment. The 226 Ra present in these materials, when undergoes radioactive decay, produces the 222Rn gas. This radioactive gas, when inhaled together with its decay products deposited in the lungs, produces the exposure to radiation and can be a potential cause of lung cancer. Thus, the objective of this study was to measure the concentration levels of 222Rn from cylindrical samples of Portland cement, gypsum and phosphogypsum mortar from the state of Paraná, as well as characterizer the material and estimate the radon concentration in an environment of hypothetical dwelling with walls covered by such materials. Experimental setup of 222Rn activity measurements was based on AlphaGUARD detector (Saphymo GmbH). The qualitative and quantitative analysis was performed by gamma spectrometry and EDXRF with Au and Ag targets tubes (AMPTEK), and Mo target (ARTAX) and mechanical testing with x- ray equipment (Gilardoni) and the mechanical press (EMIC). Obtained average values of radon activity from studied materials in the air of containers were of 854 ± 23 Bq/m3, 60,0 ± 7,2 Bq/m3 e 52,9 ± 5,4 Bq/m3 for Portland cement, gypsum and phosphogypsum mortar, respectively. These results extrapolated into the volume of hypothetical dwelling of 36 m3 with the walls covered by such materials were of 3366 ± 91 Bq/m3, 237 ± 28 Bq/m3 e 208 ± 21 Bq/m3for Portland cement, gypsum and phosphogypsum mortar, respectively. Considering the limit of 300 Bq/m3 established by the ICRP, it could be concluded that the use of Portland cement plaster in dwellings is not secure and requires some specific mitigation procedure. Using the results of gamma spectrometry there were calculated the values of radium equivalent activity concentrations (Raeq) for Portland cement, gypsum and phosphogypsum mortar, which were obtained equal to 78,2 ± 0,9 Bq/kg; 58,2 ± 0,9 Bq/kg e 68,2 ± 0,9 Bq/kg, respectively. All values of radium equivalent activity concentrations for studied samples are below the maximum level of 370 Bq/kg. The qualitative and quantitative analysis of EDXRF spectra obtained with studied mortar samples allowed to evaluate quantitate and the elements that constitute the material such as Ca, S, Fe, and others.
427

Medidas de concentração de radônio proveniente de argamassas de cimento portland, gesso e fosfogesso / Measurements of radon concentration from portland cement, gypsum and phosphogypsum mortars

Narloch, Danielle Cristine 14 September 2015 (has links)
CAPES / O cimento Portland é bastante empregado na construção civil e apresenta em sua composição o gesso natural. Para minimizar custos é possível substituir parte do gesso desta composição pelo fosfogesso. O fosfogesso é um resíduo gerado a partir da produção dos fertilizantes e é constituído, essencialmente, por cálcio dihidratado e algumas impurezas, como fluoretos, metais em geral e radionuclídeos. Atualmente, toneladas de fosfogesso são armazenadas à céu aberto próximo das indústrias de fertilizantes, causando a contaminação do meio ambiente. O elemento 226Ra, presente nesses materiais, ao passar pela série de decaimento radioativo, transforma-se em gás 222Rn. Esse gás, ao ser inalado pode decair dentro dos pulmões e neste caso, os seus produtos depositam-se nas paredes pulmonares ocasionando exposição à radiação, podendo ser um potencial causador de câncer pulmonar. Dessa forma, o objetivo desta pesquisa foi medir os níveis de concentração de 222Rn em corpos de prova de argamassa de cimento Portland, de gesso e de fosfogesso provenientes do Estado do Paraná, além de caracterizar o material e estimar a concentração de radônio em um ambiente de convívio humano hipotético construído com paredes destes materiais. Para as medidas de atividade do 222Rn foi utilizado o monitor AlphaGUARD (Saphymo GmbH). A análise qualitativa e quantitativa foi realizada por meio da espectrometria gama e da EDXRF com tubos de alvos de Au e Ag (AMPTEK), e com alvo de Mo (ARTAX) e os ensaios mecânicos com equipamento de raios X (Gilardoni) e com a prensa mecânica (EMIC). Os valores médios da atividade do radônio no ar obtidos pelo estudo dos materiais armazenados no recipiente foram de 854 ± 23 Bq/m3, 60,0 ± 7,2 Bq/m3 e 52,9 ± 5,4 Bq/m3 para argamassas de cimento Portland, de gesso e de fosfogesso, respectivamente. Estes resultados extrapolados para o ambiente hipotético de 36 m3 com paredes revestidas com os materiais foram de 3366 ± 91 Bq/m3, 237 ± 28 Bq/m3 e 208 ± 21 Bq/m3 para argamassas de cimento Portland, gesso e fosfogesso. Considerando o limite de 300 Bq/m3 estabelecido pela ICRP, observa-se que, para o revestimento de cimento Portland a exposição não é segura e requer alguns procedimentos de mitigação específicos. A partir da espectrometria gama foi calculado o valor do rádio equivalente (Raeq) para as argamassas de cimento Portland, gesso e fosfogesso que resultou em 78,2 ± 0,9 Bq/kg; 58,2 ± 0,9 Bq/kg e 68,2 ± 0,9 Bq/kg, respectivamente. Os valores do Raeq das amostras encontram-se inferiores ao limite máximo de 370 Bq/kg. Em relação a análise qualitativa e quantitativa das amostras por EDXRF, os resultados permitiram identificar e quantificar os elementos que compõe as amostras como o Ca, S, Fe, entre outros. / Portland cement being very common construction material has in its composition the natural gypsum. To decrease the costs of manufacturing, the cement industry is substituting the gypsum in its composition by small quantities of phosphogypsum, which is the residue generated by the production of fertilizers and consists essentially of calcium dihydrate and some impurities, such as fluoride, metals in general, and radionuclides. Currently, tons of phosphogypsum are stored in the open air near the fertilizer industries, causing contamination of the environment. The 226 Ra present in these materials, when undergoes radioactive decay, produces the 222Rn gas. This radioactive gas, when inhaled together with its decay products deposited in the lungs, produces the exposure to radiation and can be a potential cause of lung cancer. Thus, the objective of this study was to measure the concentration levels of 222Rn from cylindrical samples of Portland cement, gypsum and phosphogypsum mortar from the state of Paraná, as well as characterizer the material and estimate the radon concentration in an environment of hypothetical dwelling with walls covered by such materials. Experimental setup of 222Rn activity measurements was based on AlphaGUARD detector (Saphymo GmbH). The qualitative and quantitative analysis was performed by gamma spectrometry and EDXRF with Au and Ag targets tubes (AMPTEK), and Mo target (ARTAX) and mechanical testing with x- ray equipment (Gilardoni) and the mechanical press (EMIC). Obtained average values of radon activity from studied materials in the air of containers were of 854 ± 23 Bq/m3, 60,0 ± 7,2 Bq/m3 e 52,9 ± 5,4 Bq/m3 for Portland cement, gypsum and phosphogypsum mortar, respectively. These results extrapolated into the volume of hypothetical dwelling of 36 m3 with the walls covered by such materials were of 3366 ± 91 Bq/m3, 237 ± 28 Bq/m3 e 208 ± 21 Bq/m3for Portland cement, gypsum and phosphogypsum mortar, respectively. Considering the limit of 300 Bq/m3 established by the ICRP, it could be concluded that the use of Portland cement plaster in dwellings is not secure and requires some specific mitigation procedure. Using the results of gamma spectrometry there were calculated the values of radium equivalent activity concentrations (Raeq) for Portland cement, gypsum and phosphogypsum mortar, which were obtained equal to 78,2 ± 0,9 Bq/kg; 58,2 ± 0,9 Bq/kg e 68,2 ± 0,9 Bq/kg, respectively. All values of radium equivalent activity concentrations for studied samples are below the maximum level of 370 Bq/kg. The qualitative and quantitative analysis of EDXRF spectra obtained with studied mortar samples allowed to evaluate quantitate and the elements that constitute the material such as Ca, S, Fe, and others.
428

Investigação de jazidas de solos tropicais para uso em pavimentação na região metropolitana de Goiânia - GO / Investigation of deposits of tropical soils for use in flooring in the metropolitan area of &#8203;&#8203;Goiânia - GO

SILVA, Rita de Cássia 30 August 2010 (has links)
Made available in DSpace on 2014-07-29T15:18:22Z (GMT). No. of bitstreams: 1 Rita_Cassia_Silva.pdf: 4395629 bytes, checksum: 0c215c46e6dd82bf63ddafc66ab1035c (MD5) Previous issue date: 2010-08-30 / Paving is part of infrastructure investment to maintain and enhance economic growth and conditions for improving life quality. It is an activity that depends on selection and extraction of materials and requires high investments, whose availability is often limited and requires minimization of costs at all stages. Therefore, as it promotes a great economy mainly in transport, the use of appropriate materials extracted closest to the area to be paved should be taken into account in selection stage. Besides, conventional materials suitable for use in the pavement structure, such as granular materials, are scarce. Therefore, knowledge of regional materials with appropriate characteristics to the pavement is even more important. The Brazilian experience in using tropical lateritic soils in highways has been highly promising, contradicting the conventional use of the specifications adopted in the temperate regions. This experience has brought the implementation of lateritic soils and structured for this purpose the MCT (Miniature, Compressed, Tropical) methodology. From this context, the main objective of this work is to investigate soils that have suitable properties for use in paving and potential mineral deposits. The research was then conducted in two stages. The first one came from an environmental characterization, based mainly on maps, which allowed the identification of seven points for preliminary assessment of the indicated areas. The samples collected near to the surface were tested by X-ray diffraction, expeditious disk method and chemical analysis. By analyzing these points, two were chosen, where wells were dug for the analysis of soil profile. During this second phase, soil samples collected from these wells were tested for conventional characterization and support capacity by traditional method and by the MCT in order to evaluate these soils with respect to their support capacity to application to pavements. This investigation concluded that the soil properties of the two wells were favorable for the intended use. It is noteworthy, however, that although both belong to the group of Latossolos, they showed signs of being at different stages of weathering. According to the foregoing, it is believed that this research can contribute to the investigation of lateritic clay soils for use in paving as well as to enhance the city's geotechnical information, in the case Goiania, and thereby contribute to the integrated planning of future areas to be paved. / A pavimentação é uma atividade que deve ser considerada no investimento de infra-estrutura para manter ou ampliar o crescimento econômico e as condições de melhoria da qualidade de vida da população. É uma atividade que depende da seleção e da extração de materiais adequados e exige investimentos altos, cuja disponibilidade é geralmente limitada exigindo a minimização de custos em todas as etapas. Portanto, a utilização de materiais adequados mais próximos da área a ser pavimentada é um fator que deve ser levado em conta, pois promove uma grande economia, principalmente em transporte de material. Somado a isso, tem-se que os materiais convencionais adequados, no caso os granulares, para o uso na estrutura do pavimento estão escassos. Portanto, o conhecimento dos materiais regionais com características apropriadas à pavimentação é ainda mais premente. A experiência brasileira com a utilização de solos tropicais lateríticos em pavimentação tem-se mostrado bastante promissora, contradizendo o uso das especificações convencionais adotadas nas regiões de clima temperado. Esta experiência trouxe a aplicação de solos lateríticos e a estruturação da metodologia MCT (Miniatura, Compactada, Tropical) para este fim. A partir deste contexto, este trabalho tem como principal objetivo investigar solos que apresentem propriedades adequadas ao uso em pavimentação, como possíveis jazidas minerais. Para isso, esta pesquisa foi realizada em duas etapas. A primeira delas partiu de uma caracterização ambiental, embasada principalmente nos diversos mapeamentos, o que permitiu a identificação de sete pontos para avaliação preliminar das áreas mais indicadas. As amostras, coletadas próximas da superfície, foram ensaiadas por difratometria de Raios-X, método expedito da pastilha e análise química. Com a análise destes pontos, foram escolhidas dois, onde foram escavados poços para a análise do solo em perfil. Nesta segunda etapa, as amostras de solo recolhidas desses poços foram testadas em ensaios de caracterização convencional e de capacidade suporte pelo método tradicional e pela metodologia MCT, com vista à avaliação destes solos quanto à capacidade de suporte para aplicação em pavimentos. Esta investigação possibilitou, dentre outras conclusões, a verificação de que os solos dos dois poços apresentaram propriedades consideradas favoráveis para o uso pretendido. Destaca-se, entretanto, que apesar de ambos pertencerem ao grupo dos Latossolos, eles apresentaram indícios de estarem em estágios diferentes de intemperismo. De acordo com as considerações expostas, acreditase que esta pesquisa possa contribuir com a investigação dos solos argilosos lateríticos para uso em pavimentação como também para aprimorar as informações geotécnicas da cidade, no caso Goiânia, e com isso contribuir para o planejamento integrado das futuras áreas a serem pavimentadas.
429

Limitantes para Códigos de Peso Constante / Bounds for Constant-Weight Codes

RODRIGUES, Silvana da Silva 28 January 2011 (has links)
Made available in DSpace on 2014-07-29T16:02:17Z (GMT). No. of bitstreams: 1 SILVANA DA SILVA RODRIGUES.pdf: 983315 bytes, checksum: 17ccfa7762b3ec7758b0c81b7ca259bf (MD5) Previous issue date: 2011-01-28 / The main purpose of this dissertation was to construct lower and upper bounds for the cardinality of the error correcting codes for constant-weight, contained in the vector space Fn 3 , where F3 is a field with three elements, knowing parameters such as length and minimum distance code. We present the main results of linear algebra necessary to develop the theory of codes and then the fundamental concepts of more practical class of codes, the linear error correcting codes. We state the Totobola problem and the Football problem, relating them to the theory of codes and present some bounds for the "covering radius problem"for r = 1 , some values of n. In the last chapter, we conclude the work with some examples that illustrate bounds of coverings for Fn 3 , with r = 2 and 3, and the generalization of the problem, where we present the binary covering radius problem, the case of multiple coverages and the extension of the idea, citing bounds for the cardinality of the codes contained in the vector space over a finite field with any arbitrary number of elements. / O principal objetivo desta dissertação foi construir limitantes inferiores e superiores para o número de elementos de um código corretor de erros de peso constante, contido no espaço vetorial Fn 3 , onde F3 é um corpo contendo três elementos, a partir de parâmetros como comprimento e distância mínima do código. Apresentamos os principais resultados da álgebra linear necessários ao desenvolvimento da teoria de códigos e em seguida, os conceitos fundamentais da classe de códigos mais conhecida na prática: os códigos lineares. Definimos os problemas do totobola e da piscina de futebol e a relação de ambos, com a teoria de códigos e com o problema do raio de cobertura. Construímos limitantes para o problema do raio de cobertura para r = 1, a partir da variação de n, e no último capítulo o trabalho é finalizado com a apresentação de exemplos que ilustram limitantes de cobertura para Fn 3 , com r = 2 e 3 e a generalização do assunto, onde apresentamos o problema binário do raio de cobertura, o caso das múltiplas coberturas e a extensão da idéia, citando limitantes para o número de elementos de códigos contidos em espaços vetoriais sobre um corpo finito contendo uma quantidade qualquer de elementos.
430

Aplicação da técnica de eletro-floculação no tratamento de efluentes de curtume / Application of electroflocculation technique for the tannery effluent treatment

Fornari, Marilda Menchon Tavares 12 February 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:07Z (GMT). No. of bitstreams: 1 Marilda M T Fornari.pdf: 813038 bytes, checksum: 1672b5ca9a95a70d2125540cf442fb8a (MD5) Previous issue date: 2008-02-12 / In the present work has been studied the electro-flocculation efficiency on the reduction of organic and inorganic material concentrations such as Chemical Oxygen Demand (COD), turbidity, total solids and metal, mainly chromium, on an untreated tannery effluent using a pair of electrodes. For this purpose, a lab scale Electro-Flocculation (EF) reactor was constructed using an 8-L plastic cylindrical container, containing a valve in its lower part for sludge evacuation and a horizontal support in its upper part for fixing a pair of electrolytic cell in upright position into a 5-L available reactor volume. The electrodes plates, made of iron or aluminum, were connected to terminals of direct current power supply. All the physical-chemistry parameters were measured following the Standard Methods for water analysis, while metal concentrations were determined using the Synchrotron X-Ray Fluorescence technique, available in the Brazilian Synchrotron Light Laboratory. In order to determine optimal operating conditions, the effects of current intensity, electrodes distance, effluent initial pH, and EF time have been experimentally examined, according to a statistic planning and correlation analysis. For each electrode, a total of 11 EF experiments were carried out for maximum and minimum values of EF reactor operating parameters. Applying a 95% confidence level into the correlation analysis between EF parameters, the physical-chemistry parameters and metal concentrations were reduced in all of them when the effluent initial pH was increased, while the EF time and the applied voltage were reduced for small electrodes distances. Moreover, the EF treatment efficiencies tend towards higher values with an increasing on the current intensity. In order to determine the best reactor operating values, other EF experiments were performed varying the effluent initial pH from 6.5 to 9.0 and from 6.0 to 8.5 for iron and aluminum electrodes, respectively, fixing the distance between the electrodes in 4.0 cm, the current intensity in 5.5 A and the EF time in 30 minutes. Nevertheless, these EF experiments have shown that the reduction factor on parameter concentrations due to an increasing of effluent initial pH was not significant compared to prior experiments. Henceforth, the effluent pH value was maintained near to the original one for the next EF treatments, avoiding introducing other substances into the effluent. Keeping effluent pH value in 7.5, other EF experiments were performed changing the EF time from 15 to 120 min., fixing current intensities and electrode distances in 5.5 A and 4.0 cm, respectively. For these reactor conditions, the EF time setting up in 30 min. was enough to get a good efficiency according the reduction factor in the most of parameters examined, without increasing a lot the reactor electrical power, for both kinds of electrodes. The EF reactor purpose and examined has shown a high efficiency on turbidity and chromium concentration reduction factor (98%). Furthermore, this system can be also used to reduce other elementary concentrations such as calcium, potassium and zinc, for both kinds of electrodes (Fe/Al). In comparison with iron electrodes, aluminum one has reported a better reduction factor (80%) on COD values and a good reduction factor (50%) on iron concentration. On the other hand, the EF method for tanneries effluent treatment system was also compared with conventional method using coagulating and flocculating agents, showing a great similarity between them in the reduction factor. In the EF method is not necessary to introduce substances to start the coagulation and flocculation process in effluent treatment. / Este trabalho tem por objetivo o estudo da eficiência da eletro-floculação na redução das concentrações de substâncias orgânicas e inorgânicas expressas através dos parâmetros: Demanda Química de Oxigênio (DQO), turbidez, sólidos totais e metais, principalmente o cromo, em efluente de curtume não tratado, utilizando um par de eletrodos. Para esse propósito foi construído, em escala laboratorial, um reator confeccionado a partir de um recipiente plástico de 8 litros, contendo uma válvula na parte inferior, para a retirada dos sedimentos, e um suporte horizontal na parte superior para a fixação do par de células eletrolíticas, em posição perpendicular dentro do reator com volume útil de 5 litros. As placas de eletrodos, de ferro e alumínio, foram conectadas a uma fonte de alimentação de energia.Todos os parâmetros físico-químicos foram determinados seguindo o Método Padrão para análise de água, enquanto que as concentrações de metal foram determinadas através da técnica de Fluorescência de Raios X por Reflexão Total, (SR-TXRF), disponível no Laboratório Nacional de Luz Síncroton. A fim de determinar as condições ótimas de operação, os efeitos da intensidade da corrente, distância entre eletrodos, pH inicial do efluente e tempo de eletrólise foram avaliados experimentalmente, de acordo com um planejamento estatístico e análise de correlação. Para cada eletrodo, foram realizados 11 experimentos de EF com valores máximos e mínimos para os parâmetros de operação do reator. Empregando um nível de 95% de confiança na correlação de análises dos parâmetros a análise de correlação entre os parâmetros de EF, os modelos mostraram tendência de redução nas concentrações dos parâmetros físico-químicos e de metais, quando o pH inicial do efluente foi elevado, enquanto o tempo de EF e a voltagem aplicada apresentaram tendência de redução nos valores para uma menor distância entre os eletrodos.. Além disso, a eficiência do tratamento de EF tende a valores mais elevados com o aumento na intensidade de corrente. A fim de determinar as melhores condições de operação do reator, outros experimentos EF foram feitos variando o pH inicial de 6.5 a 9.0 e de 6.0 a 8.5 para eletrodos de ferro e alumínio, respectivamente, fixando a distância entre os eletrodos em 4.0 cm, a intensidade da corrente em 5.5 A e o tempo de EF em 30 minutos. Entretanto, esses experimentos mostraram que o fator de redução percentual na concentração dos parâmetros, causada pelo aumento no pH inicial do efluente, não foi significativo comparado aos experimentos anteriores. Nos tratamentos posteriores de EF, o pH do efluente foi mantido próximo ao original, evitando a introdução de outras substâncias no efluente. Mantendo o valor do pH do efluente em 7.5, outros experimentos de EF foram realizados variando o tempo de eletrólise de 15 a 120 min., e fixando a intensidade da corrente e distância entre os eletrodos em 5.5 A e 4.0 cm., respectivamente. Nessas condições, o tempo de EF fixado em 30 min. foi suficiente para alcançar uma boa eficiência, de acordo com o fator de redução, para maioria dos parâmetros analisados, sem aumentar muito a potência elétrica do reator, para os dois tipos de eletrodos. Os experimentos realizados com reator de EF mostraram uma alta eficiência na redução da turbidez e concentração de cromo (98%). Ademais, esse sistema também pode ser utilizado na redução de outras concentrações elementares como cálcio, potássio e zinco, para ambos os tipos de eletrodos (Fe/Al). Em comparação com os eletrodos de ferro, o eletrodo de alumínio apresentou um melhor fator de redução nos valores de DQO (80%) e um bom fator de redução de ferro (50%). Por outro lado, o método de EF para o tratamento de sistema de efluentes de curtumes foi também comparado ao método convencional utilizando agentes coagulantes e floculantes, mostrando uma grande semelhança entre eles no fator de redução. No método EF não é necessário introduzir substâncias para iniciar o processo de coagulação e floculação no tratamento de efluente.

Page generated in 0.0568 seconds