• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • 3
  • Tagged with
  • 111
  • 111
  • 73
  • 72
  • 41
  • 26
  • 19
  • 19
  • 16
  • 15
  • 14
  • 14
  • 14
  • 13
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Estudo de acurácia diagnóstica da glicemia capilar da borda da ferida operatória para a predição de necrose cutânea de espessura total do retalho pós-mastectomia / Diagnostic accuracy of interstitial glucose levels at the surgical wound edges to predict full thickness necrosis in mastectomy flaps

Bernardo Pinheiro de Senna Nogueira Batista 05 September 2018 (has links)
INTRODUÇÃO: As necroses de retalhos da mastectomia (RM) afetam até um terço das mulheres submetidas à reconstrução imediata de suas mamas e aumentam o risco de outras complicações e, por fim, de falha da reconstrução. A glicemia capilar (GC) tem sido usada para monitorização clínica de mudanças agudas na perfusão tecidual de retalhos livres. Nós avaliamos a acurácia diagnóstica da GC para predição de necrose de espessura total (NET) em RM após mastectomia com reconstrução imediata. MÉTODOS: Duzentos e trinta amostras de sangue para mensuração de GC foram coletadas ao longo da ferida operatória de 30 mulheres submetidas à ressecção total de suas mamas. Uma amostra de sangue periférico para mensuração da GC periférica foi colhida em cada paciente. Fotografias da mama foram capturadas no final da cirurgia e no pós-operatório (entre 7 e 14 dias). Estas fotos foram comparadas por um investigador cego aos valores das GCs para determinar a ocorrência de necrose e em que pontos de coleta ela ocorreu. A associação entre GC e a ocorrência de NET foi testada usando modelos de equações de estimação generalizadas. Nós analisamos a acurácia diagnóstica da GC como um teste intraoperatório de predição de NET usando curvas de Característica de Operação do Receptor e a estatística C (ou área sob a Curva). RESULTADOS: NET ocorreu em 21/230 (9.1%) pontos de coleta aleatória de 9/30 pacientes (30%). Cada decréscimo de 10mg/dL no valor absoluto da GC (GCA) foi associada a uma razão de chance (RC) de 1.71 (1.21-2.41; p=.002) para NET e C=.78 (.65-.92). Cada queda em 10% da razão entre a GC e a GC periférica (GCr) foi associada com uma RC=1.77 (1.23-2.55; p=.002) para NET e C=.75 (.47-.89). Para pontos de corte de GCA < 90 mg/dL ou GCR < 80%, a especificidade e sensibilidade para o teste como uma ferramenta de rastreamento para NET foi de 67% (14/21) e 86% (179/209), respectivamente. CONCLUSÕES: A performance da GC como uma ferramenta de rastreamento para NET foi sub ótima, com um poder discriminatório moderado. No entanto, sua mensuração pode ser informativa como uma ferramenta adicional para esta avaliação ainda altamente subjetiva. As associações observadas entre a GC e a ocorrência de NET pós-operatória suportam nossa hipótese de que os tecidos dos RM sob stress perfusional demonstram alterações metabólicas precoces / INTRODUCTION: Mastectomy skin flap (MSF) necrosis affects up to one-third of patients undergoing immediate breast reconstruction and increases the risk other complications rand, ultimately, reconstruction failure. Interstitial glucose level (IGL) has been used clinically to monitor acute changes in local tissue perfusion in free flaps. We evaluated the accuracy of IGL for prediction of full thickness necrosis (FTN) in MSF after mastectomy with immediate breast reconstruction. METHODS: Two hundred and thirty random blood samples for IGL measurement along the surgical wound edges of 30 women undergoing unilateral total breast resection with immediate reconstruction were collected. At the same time, a peripheral blood sample was also tested. Pictures of the breast were taken after skin closure with markings identifying the position where the samples were taken and 7 to 14 days post-operatively. These pictures were compared by an investigator blinded to IGL values to determine the occurrence of FTN and at which IGL sampling sites it occurred. The association between IGL and the occurrence of FTN was tested using generalized estimating equation models. We analyzed the diagnostic accuracy of IGL as an intraoperative test for FTN with the use of Receiver Operating Curves and their C-statistics (or Area Under the Curve). RESULTS: FTN occurred in 21/230 (9.1%) random sampling points from 9/30 patients (30%). Each 10mg/dL decrease in absolute IGL (IGLA) was associated with an OR=1.71 (1.21-2.41; p=.002) for FTN and C=.78 (.65-.92). Each 10% decrease in the ratio of IGL to peripheral glucose level (IGLR) was associated with an OR=1.77 (1.23-2.55; p=.002) for FTN, with C=.75 (.47-.89). For cut-offs of IGLA < 90 mg/dL or IGLR < 80%, the specificity and sensitivity of the test as a screening tool for FTN were 67% (14/21) and 86% (179/209), respectively. CONCLUSIONS: The performance of IGL as a screening tool for FTN was suboptimal, with a moderate discriminative power for FTN. However, it can be informative as an additional tool to the still highly subjective intraoperative evaluation of MSFs. The observed association between IGL measurements and post-operative FTN supports our hypothesis that tissues of the MSF under perfusion stress will show early metabolic alterations
52

Validação de uma ferramenta de triagem para disfagia / Validation of a screening tool for dysphagia

Maira Santilli de Lima 21 August 2018 (has links)
INTRODUÇÃO: A disfagia orofaríngea gera impacto negativo na qualidade de vida e saúde dos indivíduos que a possuem, aumentando também a taxa de morbidade e a necessidade de cuidados. A utilização de protocolos padronizados para a triagem da disfagia em serviços hospitalares auxilia o diagnóstico e tratamento precoce, reduzindo complicações clínicas, tempo de permanência e custos hospitalares. Essas ferramentas devem ser simples e apresentar alta sensibilidade quando comparadas aos exames objetivos de avaliação da deglutição. OBJETIVO: o objetivo do presente estudo foi realizar a validação de um instrumento simples de triagem da disfagia utilizado em um hospital público de grande porte no Brasil em população adulta heterogênea. MÉTODO: O Protocolo de Avaliação de Risco para Disfagia versão de triagem (PARDt) contém quatro itens (ausculta cervical alterada, alteração da qualidade vocal, tosse e engasgo antes/durante/após a deglutição) que foram previamente indicados como fatores de risco independentes associados à presença de disfagia no teste de deglutição com água. Fonoaudiólogos treinados administraram e classificaram o PARDt para pacientes consecutivos encaminhados pela equipe médica do hospital para realizar a videofluoroscopia da deglutição (VDF). Vinte por cento de todos os pacientes inscritos foram aleatoriamente alocados para a realização da VDF, menos de 24 horas após serem submetidos ao PARDt. RESULTADOS: No total, 211 pacientes receberam a triagem da deglutição, sendo que desses, 99 falharam (com disfagia) e 112 passaram (sem disfagia). Um em cada cinco pacientes foi randomizado para receber a VDF, ou seja, 42 pacientes. Comparando os achados da avaliação clínica da deglutição com os achados da VDF, a versão de triagem do PARD demonstrou excelente validade, com sensibilidade de 92,9%, especificidade de 75,0%, valores preditivos negativos de 95,5% e acurácia de 80,9%. CONCLUSÃO: O PARDt é uma ferramenta simples e precisa para identificar a penetração e/ou aspiração em pacientes que não são alimentados por sonda, que apresentam bom nível de alerta, sem histórico de pneumonias de repetição, que não estejam em vigência de pneumonia e que não façam uso de cânula de traqueostomia / INTRODUCTION: Oropharyngeal dysphagia can have a negative impact on the quality of life and health of the individuals who have it, increasing the morbidity rate and the need for care. The use of standardized dysphagia screening protocols in hospital services helps diagnosis and early treatment, reducing clinical complications, length of stay and hospital costs. These tools should be simple and have high sensitivity when compared to objective examinations of swallowing assessment. OBJECTIVE: The purpose of the present study was to assess the validity of a simple instrument for screening dysphagia used in a large public hospital in Brazil with heterogeneous adult population. METHODS: The Dysphagia Risk Evaluation Protocol (DREP) - screening version contains four items (altered cervical auscultation, altered vocal quality, coughing and choking before / during / after swallowing) that were previously indicated as independent risk factors associated to the presence of dysphagia in the swallowing test with water. Trained speech therapists administered and scored DREP - screening version to consecutive patients referred by hospital\'s medical team to perform videofluoroscopy for swallowing (VSFF). Twenty percent of all enrolled patients were then randomly allocated to perform VSFF, less than 24 hours after being submitted to the DREP - screening version. RESULTS: A total of 211 patients were screened for swallowing, of which 99 failed (with dysphagia) and 112 passed (without dysphagia). One in five patients was randomized to receive VSFF, that is, 42 patients. Comparing the findings of the clinical evaluation of swallowing with the VSFF findings, the DREP - screening version showed excellent validity, with sensitivity of 92.9%, specificity of 75.0%, predictive values of 95.5% and accuracy of 80.9%. CONCLUSION: The DREP - screening version is a simple and accurate tool to identify penetration and / or aspiration in patients who are not tube-fed, who have a good level of alertness, have no history of recurrent pneumonia, are not on pneumonia, and that do not use a tracheostomy cannula
53

Ecoendoscopia versus colangiorressonância magnética nuclear no diagnóstico da coledocolitíase: revisão sistemática / Endoscopic ultrasound versus magnetic resonance cholangiopancreatography in suspected choledocholithiasis: a systematic review

Vinicius Leite de Castro 27 April 2018 (has links)
Introdução: Atualmente há falta de consenso quanto à melhor estratégia diagnóstica não invasiva em pacientes com suspeita clínica de coledocolitíase. Duas revisões sistemáticas anteriores não demonstraram diferença estatisticamente significativa para detecção de coledocolitíase entre duas modalidades diagnósticas: Ecoendoscopia e Colangiorressonância Magnética Nuclear (CRMN). Entretanto, após a última revisão, outro estudo foi publicado resultando em um incremento significativo na amostra populacional a ser analisada. Objetivo: Comparar os resultados diagnósticos da Ecoendoscopia e da CRMN em pacientes com suspeita clínica de coledocolitíase por intermédio de revisão sistemática. Métodos: Realizou-se pesquisa nos bancos de dados eletrônicos da Medline, Embase, Cochrane, LILACS e Scopus em busca de estudos prospectivos que comparassem a Ecoendoscopia e CRMN na detecção de coledocolitíase, datados anteriormente a setembro de 2017. Todos os pacientes deveriam ter sido submetidos a teste padrão-ouro a fim de confirmação diagnóstica. Os estudos foram submetidos ao Quality Assessment of Diagnostic Accuracy Studies para análise de vieses. As variáveis analisadas e comparadas foram sensibilidade, especificidade, prevalência, valor preditivo positivo, valor preditivo negativo e acurácia. Resultados: Foram selecionados oito estudos prospectivos comparando Ecoendoscopia e CRMN no diagnóstico da coledocolitíase. Um total de 538 pacientes foram incluídos na análise. A probabilidade pré-teste para coledocolitíase foi 38,7%. As sensibilidades médias da Ecoendoscopia e da CRMN para detecção de coledocolitíase foram 93,7% e 83,5% respectivamente, e as especificidades foram 88,5% e 91,5%, respectivamente. As probabilidades pós-teste também foram calculadas: valores preditivos positivos de 89% e 87,8%, respectivamente, e valores preditivos negativos de 96,9% e 87,8%. As acurácias foram 93,3% e 89,7%, respectivamente. Conclusão: Para a mesma probabilidade pré-teste de coledocolitíase, a Ecoendoscopia demonstra maior sensibilidade e acurácia quando comparada à CRMN / Background: There is a lack of consensus about the optimal noninvasive strategy for patients with suspected choledocholithiasis. Two previous systematic reviews demonstrated no statistically significant difference between Endoscopic Ultrasound (EUS) and Magnetic Resonance Cholangiopancreatography (MRCP) for detection of choledocholithiasis. A recent publication provided new data to be analyzed. Objective: To compare the diagnostic results of Endoscopic Ultrasound and Magnetic Resonance Cholangiopancreatography in choledocholithiasis suspected patients. Methods: A systematic review was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses recommendations including all published prospective trials. Medline, Embase, Cochrane, LILACS and Scopus databases were scanned until September 2017. All patients were submitted to a gold-standard method. The selected studies were submitted to Quality Assessment of Diagnostic Accuracy Studies. Aggregated variables such as sensitivity, specificity, prevalence, positive and negative predictive values and accuracy were analyzed. Results: A total of eight prospective trials comparing EUS and MRCP including 538 patients were analyzed. The pretest probability for choledocholithiasis was 38.7. The mean sensitivity of EUS and MRCP for detection of choledocholithiasis was 93.7 and 83.5, respectively; the specificity was 88.5 and 91.5, respectively. The positive predictive value was 89 and 87.8, respectively; the negative predictive value was 96.9 and 87.8 respectively. The accuracy was 93.3 and 89.7, respectively. Conclusion: For the same pretest probability of choledocholithiasis, EUS has higher sensitivity and accuracy compared to MRCP
54

Avaliação da sensibilidade cutânea em pés de pacientes diabéticos através do Pressure Specified Sensory Device TM / Evaluation of cutaneous sensibility threshold on the feet of diabetic patients with the Pressure Specified Sensory Device(TM)

Carvalho, Viviane Fernandes de 04 March 2008 (has links)
A neuropatia diabética causa diminuição ou perda da sensibilidade protetora do pé, tornando-o mais vulnerável ao trauma mecânico e térmico. A profilaxia das complicações neuropáticas tem início pela identificação da perda de sensibilidade e, portanto, do comprometimento neurológico. O Pressure Specified Sensory Device(TM) (PSSD) é um equipamento desenvolvido para quantificar o limiar de pressão, aplicada sobre a pele, necessária para que o paciente perceba o estímulo provocado por: um ponto estático, um ponto em movimento, dois pontos estáticos e dois pontos em movimento. Denominamos grupo estudo, aos trinta e quatro pacientes diabéticos do tipo 2, sem história prévia de feridas e/ou amputações nos pés que foram submetidos à avaliação de sensibilidade cutânea utilizando-se o PSSD(TM). Foram realizados testes nos territórios cutâneos dos nervos fibular profundo, plantar medial e ramo calcâneo do nervo tibial posterior. Estímulos foram provocados segundo as modalidades: um ponto estático (1 PE), um ponto em movimento (1 PD), dois pontos estáticos (2 PE) e dois pontos em movimento (2 PD), para as duas últimas modalidades. Previamente às modalidades 2PE e 2PD determinou-se o limiar de discriminação entre dois pontos estáticos (D2PE) e em movimento (D2PD). Foram realizados apenas no grupo estudo, testes com o monofilamento de Semmes-Weisntein nº 5,07 (MSW) e com o diapasão de 128 Hz. Vinte e oito pacientes não-diabéticos, submetidos aos mesmos testes, formaram o grupo controle. Para os limiares de sensibilidade, encontramos valores superiores no grupo estudo (p < 0,05). Ao compararmos os limiares de sensibilidade alcançados pelos pacientes diabéticos sensíveis e não sensíveis ao estímulo promovido pelo MSW nº 5,07 verificamos que o p-valor variou entre 0,018 < p < 0,113 para 1 PE e 0,002 < p < 0,083 para 2 PE, conforme o território cutâneo estudado. Na comparação dos limiares de sensibilidade da modalidade 1 PD entre diabéticos sensíveis e insensíveis à vibração do diapasão de 128 Hz, as diferenças não foram estatisticamente significantes (p = 0,183). Os resultados obtidos nos permitiram sugerir que o dispositivo PSSD(TM) seja utilizado como forma de acompanhamento do comprometimento da fibra nervosa. / Neuropathy is a severe progressive loss of protective sensation on the feet, making the patient more vulnerable to mechanical trauma and consequently more suitable to the development of chronic wounds, major distortion of the foot bone architecture and eventually to limb amputation. Prophylaxis should be enforced to avoid foot ulceration and for that, evaluation of the degree of loss of sensation on the skin is essential. The PSSD (Pressure Specified Sensory Device(TM)) was developed in order to quantify the threshold of pressure applied to the skin that could be recognized as positive by the patient. Pressure of one or two points is tested both statically and with movement, thus assessing the function of fast and slow response nerve fibers. Threshold of two-point discrimination was also measured in mm. Thirty four (n = 34) diabetic patients, type II, with no previous history of wounds on the lower extremity were studied using the tests, one point static (1PE), one point moving (1PD) and two points static (2 PE), and moving (2 PD) on the cutaneous territory of the fibular nerve and posterior tibial nerve (two territories - medial plantar and calcaneous nerves). The control group (28 non diabetic patients) was assessed by the same exams and the results were compared. In the diabetic group the cutaneous territories were also evaluated using the conventional Semmes-Weinstein filament nº 5,07 e vibrometer of the 128 Hz. Altered values were observed for the static and dynamic tests over the three studied nerve territories. The differences were statically significant (p < 0,05). Comparing the threshold of sensibility between sensitive and non sensitive diabetic patients to MSW nº 5,07 test, we observed that p-value range was 0,018 0,113 when 1PE test was applied, and 0,002 0,083 when 2PE test was applied, according to the cutaneous territories evaluated. Numeric quantification of the threshold of pressure allows us to determine the status of the fiber/receptor structures as well as the functional deficit of nerve fibers. Our findings suggest that PSSD(TM) is an adjuvant tool to evaluate the degree of loss of sensation on the skin.
55

A escala de avaliação de demência (DRS) no diagnóstico de comprometimento cognitivo leve e doença de Alzheimer / The dementia rating scale (DRS) in the diagnosis of mild cognitive impairment and Alzheimer´s disease

Porto, Claudia Sellitto 14 September 2006 (has links)
A Escala de Avaliação de Demência (Dementia Rating Scale -DRS), proposta por Steven Mattis (1988), tem sido bastante utilizada na avaliação de pacientes com demência tanto na atividade clínica como na pesquisa. Consiste de 5 subescalas: Atenção, Iniciativa/Perseveração, Construção, Conceituação e Memória. Neste estudo, a Escala de Avaliação de Demência foi aplicada em 56 pacientes com doença de Alzheimer com demência de intensidade leve; 55 pacientes com diagnóstico de comprometimento cognitivo leve; e, 60 indivíduos controles. Na diferenciação entre pacientes com doença de Alzheimer e controles a nota de corte de < 128 demonstrou 90,0% de sensibilidade e 89,3 % de especificidade; e, entre pacientes com doença de Alzheimer e comprometimento cognitivo leve, a nota de corte foi < 123 com sensibilidade de 78,2% e 76,8% de especificidade. Na diferenciação entre pacientes com comprometimento cognitivo leve e controles, a nota de corte foi de < 134 com 73,3% de sensibilidade e 72,7% de especificidade. A DRS demonstrou ser um instrumento com boa acurácia diagnóstica na discriminação entre pacientes com doença de Alzheimer de intensidade leve e indivíduos controles. A DRS também foi capaz de diferenciar entre pacientes com comprometimento cognitivo leve de controles, e pacientes com comprometiemnto cognitivo leve de pacientes com doença de Alzheimer de intensidade leve. As subescalas Memória e Iniciativa/Perseveração demonstraram maior acurácia diagnóstica em todas as situações analisadas quando comparadas às demais subescalas. / The Dementia Rating Scale (DRS), proposed by Steven Mattis (1988), it has been very used to assess patients with dementia both in clinical practice and research. Consists of 5 subscales: Attention, Initiation/Perseveration, Construction, Conceptualization and Memory. The Dementia Rating Scale was applied to 56 patients with Alzheimer´s disease, witha dementia of mild intensity; 55 patients with diagnosis of mild cognitive impairment; and, 60 controls. Between patients with Alzheimer´s disease and controls the cutoff score of <128 showed a 90.0% of sensitivity and 89.3% of specificity; and, between patients with Alzheimer´s disease and mild cognitive impairment, the cutoff score was <123 with sensitivity of 78.2% e 76.8% of specificity. In the analysis between patients with mild cognitive impairment and controls, the cutoff score was <134 with 73.3% of sensitivity and 72.7% of specificity. The Dementia Rating Scale showed to be a instrument with good diagnostic accuracy in the discrimination between patients with mild Alzheimer´s disease and controls. The Dementia Rating Scale also was able to discriminated between patients mild cognitive impairment and controls, and between patients with mild cognitive impairment and mild Alzheimer´s disease. The Memory and Initiation/Perseveration subscales showed good diagnostic accuracy in all analysed situations.
56

Colangiopancreatografia retrógrada endoscópica versus ultrassom endoscópico no diagnóstico histológico da estenose biliar maligna: revisão sistemática e metanálise / ERCP versus EUS for tissue diagnosis of malignant biliary stricture: systematic review and meta-analysis

Moura, Diogo Turiani Hourneaux de 07 March 2016 (has links)
Introdução: O diagnóstico histológico das estenoses biliares é fundamental na definição da terapêutica a ser empregada, devido à heterogeneidade dos resultados dos estudos comparando o uso do escovado citológico e da biópsia transpapilar na colangiopancreatografia retrógada endoscópica (CPRE) com a punção aspirativa ecoguiada com agulha fina (ECO-PAAF) no diagnóstico histológico da estenose biliar maligna, e o fato de não existirem revisões sistemáticas e metanálises comparando esses métodos, este estudo propõe comparar esses dois métodos no diagnóstico histológico da estenose biliar maligna, através de revisão sistemática e metanálise da literatura. Métodos: Utilizando as bases de dados eletrônicas Medline, Embase, Cochrane, LILACS, CINAHL, e Scopus foram pesquisados estudos datados anteriormente a novembro de 2014. De um total de 1009 estudos publicados, foram selecionados três estudos prospectivos comparando ECO-PAAF e CPRE no diagnóstico histológico da estenose biliar maligna e cinco estudos transversais comparando ECO-PAAF com o mesmo padrão-ouro dos outros três estudos comparativos. Todos os pacientes foram submetidos ao mesmo padrão-ouro. Foram calculadas as variáveis do estudo (prevalência, sensibilidade, especificidade, valores preditivos positivos e negativos e acurácia) e realizada a metanálise utilizando os softwares Rev Man 5 e Meta-DiSc 1.4. Resultados: Um total de 294 pacientes foi incluído na análise. A probabilidade pré-teste para estenose biliar maligna foi de 76,66%. As sensibilidades médias da CPRE e da ECO-PAAF para o diagnóstico histológico da estenose biliar maligna foram de 49% e 76,5%, respectivamente; especificidades foram de 96,33% e 100%, respectivamente. As probabilidades pós-teste também foram determinadas: valores preditivos positivos de 98,33% e 100%, respectivamente, e valores preditivos negativos de 34% e 58,87%. As acurácias foram 60,66% e 82,25%, respectivamente. Conclusão: A ECO-PAAF é superior a CPRE com escovado citológico e/ou biópsia transpapilar no diagnóstico histológico da estenose biliar maligna. No entanto, um teste de ECO-PAAF ou CPRE com amostra histológica negativa não pode excluir a estenose biliar maligna, pois ambos os testes apresentam baixo valor preditivo negativo / Background and Aims: Due the heterogeneity of the results of studies comparing the use of ERCP-based brush cytology and forceps biopsy and EUS-guided fine-needle aspiration for the diagnosis of malignant biliary stricture, and the fact that there are no systematic reviews and meta-analysis comparing these methods, in this review, we will compare ERCP against EUS-FNA for tissue diagnosis of malignant biliary stricture. Design: A systematic review of comparative studies (prospective or retrospective) was conducted analyzing EUS and ERCP for tissue diagnosis of malignant biliary stricture. Methods: The databases Medline, EMBASE, Cochrane, LILACS, CINAHL, and Scopus were searched for studies dated previous to November 2014. We identified three prospective studies comparing EUS-FNA and ERCP for the diagnosis of malignant biliary stricture and five cross sectional studies comparing EUS-FNA with the same gold standard of the other three studies. All patients were submitted to the same gold standard method. We calculated study variables (prevalence, sensitivity, specificity, positive and negative predictive values, and accuracy) and performed a meta-analysis using the Rev Man 5 and Meta-DiSc 1.4 softwares. Results: A total of 294 patients were included in the analysis. The pretest probability for malignant biliary stricture was 76.66%. The mean sensitivities of ERCP and EUS-FNA for tissue diagnosis of malignant biliary stricture were 49% and 76.5%, respectively; specificities were 96.33% and 100%, respectively. The post-test probabilities, positive predictive value (98.33% and 100%, respectively) and negative predictive value (34% and 58.87%, respectively) were determined. The accuracies were 60.66% and 82.25%, respectively. Conclusion: EUS- FNA is superior to ERCP with brush cytology and forceps biopsy for diagnosing malignant biliary strictures. However, a negative EUS-FNA or ERCP test may not exclude malignant biliary stricture because both have low negative post-test probabilities
57

Predição da restrição do crescimento fetal pela medida da altura uterina / Prediction of fetal growth restriction by uterine height

Martinelli, Silvio 08 March 2004 (has links)
O objetivo deste estudo foi verificar o poder de predição da medida da altura uterina para a restrição do crescimento fetal (RCF), por meio da curva de MARTINELLI et al. (2001), tendo como limite o percentil 5 e 10 para a idade gestacional e comparar com a curva de BELIZÁN et al. (1978). Entre julho de 2000 e fevereiro de 2003, 238 gestantes de alto risco foram submetidas a medidas de altura uterina, da 20a à 42a semana de gestação. Todas possuíam idade gestacional confirmada por ultra-sonografia precoce. A confirmação do diagnóstico de RCF foi dada após o nascimento pela curva de RAMOS (1983). Entre as gestantes, 50 (21,0%) tiveram recém-nascidos pequenos para a idade gestacional. O mesmo observador realizou 1617 medidas de altura uterina, com fita métrica, da borda superior da sínfise púbica ao fundo uterino. Para a ocorrência de RCF, considerando um exame positivo se uma medida de altura uterina encontrava-se abaixo do percentil 10 para a idade gestacional na curva de MARTINELLI et al. (2001), a sensibilidade (S) foi de 78%, especificidade (E) de 77,1%, valor preditivo positivo (VPP) de 47,6% e valor preditivo negativo (VPN) de 92,9%. Utilizando como limite o percentil 5, foram obtidos S= 64%, E= 89,9%, VPP= 62,7% e VPN= 90,4%, para o diagnóstico da RCF. Utilizando-se a curva de BELIZÁN et al. (1978) e considerando positivo exame com um valor abaixo do percentil 10 para a idade gestacional, os resultados encontrados foram S= 54%, E= 97,3%, VPP= 84,4% e VPN= 88,8% para a identificação da RCF. Comparada à curva de BELIZÁN et al. (1978), a curva de altura uterina de MARTINELLI et al. (2001) apresentou maior sensibilidade e valor preditivo negativo, consistindo em método de triagem mais adequado para a RCF / The aim of this study was to correlate uterine height measurements below the 5th and 10th percentiles using MARTINELLI et al. (2001) curve to fetal growth restriction (FGR) and to compare with the BELIZÁN et al. (1978) curve. During the period of July 2000 and February 2003, 238 pregnant women of high risk were submitted to uterine height measurements between the 20th and 42nd weeks of gestation. The whole group had well-known gestational age, confirmed by early ultrasound. The diagnosis of FGR was confirmed after birth according to RAMOS (1983). Among these women, 50 (21,0%) gave birth to light for gestational age infants. The same observer, using tape measure, performed 1617 uterine height measurements, from the upper border of the symphysis pubis to the fundus uteri. For the diagnosis of FGR, being considered as positive the exam with measurements below the 10th percentile according to MARTINELLI et al. (2001) curve, the sensitivity (SE), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) were 78,0%, 77,1%, 47,6% and 92,9%, respectively. For the 5th percentile, this curve showed SE= 64,0%, SP= 89,9%, PPV= 62,7% and NPV= 90,4% for the detection of FGR. The BELIZÁN et al. (1978) curve, having the 10th percentile as the limit, yielded SE= 54,0%, SP= 97,3%, PPV= 84,4% and NPV= 88,8% for the identification of FGR. We conclude that, when used for screening FGR, the MARTINELLI et al. (2001) curve showed greater sensitivity and negative predictive value, and presents better results than that of Belizán et al. (1978)
58

Sensibilidade e especificidade do Sistema Manchester de Classificação de Risco na priorização de pacientes com infarto agudo do miocárdio que apresentam dor torácica / Sensitivity and specificity of Manchester Triage System in the prioritization of patients with acute myocardial infarction who present chest pain.

Nishi, Fernanda Ayache 09 June 2017 (has links)
Introdução: O Sistema Manchester de Classificação de Risco tem como objetivo definir a prioridade clínica para atendimento médico de pacientes nos serviços de emergência. A avaliação de pacientes com suspeita de infarto agudo do miocárdio com sintomas típicos como a dor torácica realizada por meio do Sistema Manchester exige adequada sensibilidade e especificidade do sistema ao determinar a prioridade para atendimento médico. Objetivos: Os objetivos deste estudo foram integrar as melhores evidências disponíveis quanto a sensibilidade e especificidade do Sistema Manchester na classificação de pacientes com relação ao diagnóstico de síndrome coronariana aguda; estimar a sensibilidade e especificidade do Sistema Manchester na classificação de pacientes com dor torácica para a adequada priorização no que se refere ao diagnóstico de infarto agudo do miocárdio num hospital geral de ensino na cidade de São Paulo; e verificar associação entre o desempenho do Sistema Manchester na avaliação desses pacientes e variáveis selecionadas. Método: Este estudo foi desenvolvido em duas etapas, sendo a primeira uma revisão sistemática da literatura realizada segundo metodologia de revisões de acurácia de testes diagnósticos do Joanna Briggs Institute. Na segunda etapa do estudo foram estimadas a sensibilidade e a especificidade do Sistema Manchester na avaliação de pacientes com infarto agudo do miocárdio por meio de um estudo metodológico, transversal e retrospectivo. A sensibilidade e a especificidade do Sistema Manchester foram estimadas por meio da verificação da classificação estabelecida para pacientes com dor torácica que receberam ou não o diagnóstico médico de infarto agudo do miocárdio após a classificação. Resultados: Foram incluídos na revisão sistemática seis estudos com total de 54.176 participantes, todos de qualidade metodológica moderada, que apontaram valores de sensibilidade entre 70% e 80%. Dois estudos que apresentaram os dados necessários para o cálculo de especificidade, tiveram valores calculados de 59% e 97%. A amostra do estudo primário incluiu 10.087 episódios de classificação, sendo 52,3% de pacientes do sexo feminino com média de idade de 43,6 anos (DP=17,6). Do total de episódios, 139 tinham diagnóstico de infarto. A sensibilidade do Sistema Manchester foi de 44,6% e a especificidade foi de 91,3%. Houve associação estatisticamente significativa entre o desempenho do Sistema Manchester e a idade dos pacientes (p<0,001), com maior frequência de classificação incorreta nas faixas etárias mais altas. Não houve associação entre o sexo dos pacientes e o desempenho do Sistema Manchester. Conclusão: a recomendação para uso do Sistema Manchester na avaliação de pacientes no serviço de urgência em relação ao diagnóstico de síndrome coronariana aguda foi de grau B segundo graus de recomendação estabelecidos pelo Joanna Briggs Institute, o que remete a uma recomendação \"fraca\" para uma determinada estratégia de gestão da saúde. Essa conclusão decorre sobretudo da heterogeneidade dos critérios de inclusão e portanto das amostras dos estudos incluídos. Os resultados do estudo evidenciam a necessidade de se discutir formas de melhorar a sensibilidade desse sistema para a adequada priorização de pacientes com dor torácica. / Introduction: The Manchester Triage System aims to define the clinical priority of patients for medical care in the emergency department. The evaluation of patients with suspected acute myocardial infarction presenting typical symptoms such as chest pain using the Manchester Triage System requires proper sensitivity and specificity of the system in order to determine medical care priority. Objectives: The objectives of this study were: to integrate the best available evidence regarding the sensitivity and specificity of the Manchester Triage System in the evaluation of patients with the diagnose of acute coronary syndrome; to estimate the sensitivity and specificity of the Manchester Triage System in the classification of patients with chest pain to adequate prioritization in relation to the diagnose of acute myocardial infarction in a general teaching hospital in the city of São Paulo; to verify the association between the performance of the Manchester Triage System in the evaluation of these patients and selected variables. Methods: This study was developed in two stages, the first one consisted in a systematic review performed according to the methodology of diagnostic test accuracy systematic reviews from Joanna Briggs Institute. In the second stage of the study the sensitivity and specificity of the Manchester Triage System in the evaluation of patients with acute myocardial infarction were estimated though a methodological retrospective cross-sectional study. The sensitivity and specificity of the Manchester Triage System were estimated by verifying the classification of patients with chest pain who received or not the medical diagnosis of acute myocardial infarction. Results: The systematic review included six studies with a total of 54,176 participants, all of the studies with moderate methodological quality. The studies pointed sensitivity values from 70% to 80%. The specificity values calculated from two studies containing the necessary data were 59% and 97%. The sample of the performed primary study included 10,087 episodes of classification, 52.3% of the patients were females with average age of 43.58 years (SD=17.6). Of the total episodes, 139 had the diagnosis of infarction. The sensitivity of the Manchester Triage System was 44.6% and the specificity was 91.3%. There was statistically significant association between the performance of the Manchester Triage System and the age of the patients (p<0.001), with a higher frequency of incorrect classification in the older age groups. There was no observed association between the sex of the patients and the performance of the Manchester Triage System. Conclusion: Recommendation for the utilization of the Manchester Triage System in the evaluation of patients in emergency services to correct prioritization related to the diagnose of acute coronary syndrome was graded B according to the Joanna Briggs Institute grades of recommendation, which refers to a weak recommendation to a certain strategy for healthcare management. This finding is due to the heterogeneity of the inclusion criteria and therefore the samples of the included studies. The results of this study highlight the necessity of discussion about ways to improve the sensitivity of this system, for the adequate prioritization of patients with chest pain.
59

Acurácia da ressonância magnética na detecção de roturas e de instabilidade na porção intra-articular do tendão da cabeça longa do bíceps braquial em pacientes submetidos a reparo do manguito rotador / Accuracy of magnetic resonance imaging in the detection of tears and instability in the intra-articular portion of the long head of biceps tendon in patients undergoing rotator cuff repair

Baptista, Eduardo 05 February 2019 (has links)
A literatura a respeito da capacidade da ressonância magnética em avaliar as afecções do tendão da cabeça longa do bíceps é escassa, a despeito da importância destas condições na gênese da dor e da disfunção do ombro. O objetivo primário deste estudo foi analisar o desempenho diagnóstico da ressonância magnética na detecção de roturas e de instabilidade na porção intra-articular deste tendão, comparando os achados de imagem com os dados de cirurgia artroscópica (padrão de referência). Foram objetivos secundários determinar as reprodutibilidades intraobservador e interobservador, avaliar a capacidade da ressonância magnética em classificar os tipos de rotura, avaliar a acurácia da associação entre alterações tendíneas e roturas do manguito rotador na instabilidade, além de pesquisar fatores preditores da acurácia da ressonância magnética. Foi realizado estudo transversal, com segmentos retrospectivo e prospectivo. Os critérios de inclusão foram indicação de cirurgia artroscópica do ombro para reparo do manguito rotador e exame de ressonância magnética préoperatória. Os critérios de exclusão foram: manipulação cirúrgica pregressa no ombro estudado; exames com imagens de má qualidade; intervalo entre exame pré-operatório e procedimento cirúrgico superior a um ano; indicação de técnica cirúrgica por via aberta. Foram estudados 100 ombros de 98 pacientes, operados consecutivamente de abril de 2013 a março de 2017 (47 meses). Todos os pacientes realizaram ressonância magnética de 1,5 Tesla em nossa instituição, sem utilização de contraste intra-articular. Todas as cirurgias foram realizadas pelos mesmos 3 cirurgiões, com 10 a 12 anos de experiência em cirurgia do ombro e cotovelo. Dois radiologistas, com 4 e 8 anos de experiência na área musculoesquelética, avaliaram as imagens de todos os exames, de forma independente e sem conhecimento prévio dos resultados intra-operatórios. Os mesmos casos foram revistos por um dos radiologistas, 4 meses após a primeira análise. Nossos resultados demostraram desempenho diagnóstico moderado da ressonância magnética para detecção de roturas do bíceps, com sensibilidades entre 71,1% a 73,3%, especificidades de 72,7% e acurácia entre 72 e 73%. A reprodutibilidade interobservador foi substancial (coeficiente Kappa de 0,62 a 0,69) e a reprodutibilidade intraobservador foi substancial ou quase perfeita na avaliação das roturas (coeficiente Kappa de 0,74 a 0,82). Houve correlação moderada entre os métodos para classificar o tipo de rotura (coeficiente Kappa de 0,38 a 0,47). Quando consideradas roturas completas, foram calculadas especificidades entre 75,0% e 95,7%, porém sensibilidades de 55,6% a 66,7%. Para o diagnóstico de instabilidade, observa-se sensibilidade de 52,4% a 59,1%, especificidade de 70,5% a 84% e acurácia de 64,4% a 69,5%. A avaliação combinada do deslocamento tendíneo e das roturas do manguito rotador resultou em sensibilidades de 17,5% a 47,7% e especificidades de 72,7% a 90,7%. A reprodutibilidade interobservador foi substancial (coeficiente Kappa de 0,59 a 0,7) e a reprodutibilidade intraobservador foi substancial ou quase perfeita (coeficiente Kappa de 0,76 a 0,80) para avaliação de instabilidade. Não identificamos fatores preditores para acurácia da ressonância magnética na pesquisa dessas afecções / There is paucity of literature regarding the performance of magnetic resonance imaging to assess long head of the biceps tendon disorders, despite the importance of such disorders in the genesis of pain and shoulder dysfunction. The primary objective of this study was to analyze the diagnostic performance of magnetic resonance imaging in the detection of tears and instability of the intra-articular portion of this tendon, comparing imaging findings with data from arthroscopic surgery (reference standard). Secondary objectives were to determine intraobserver and interobserver reproducibility; to evaluate the capability of MRI to classify types of tears; to evaluate the accuracy of the association between tendon displacement and rotator cuff tears to predict instability; to investigate predictive factors of magnetic resonance accuracy. A cross-sectional study was carried out, with retrospective and prospective segments. Inclusion criteria were indication of arthroscopic shoulder surgery for rotator cuff repair and preoperative magnetic resonance imaging. Exclusion criteria were: previous surgical manipulation in the studied shoulder; poor quality images; interval between preoperative examination and surgical procedure above one year; and indication of open surgical technique. We studied 100 shoulders of 98 consecutively operated patients from April 2013 to March 2017 (47 months). All patients underwent magnetic resonance imaging at our institution, using a 1.5 Tesla scanner, without use of intra-articular contrast. All surgeries were performed by the same 3 surgeons, with 10 to 12 years of experience in shoulder and elbow surgery. Two radiologists, with 4 and 8 years of experience in musculoskeletal radiology, evaluated the images independently and without previous knowledge of the intraoperative results. The same cases were reviewed by one of the radiologists, 4 months after the first analysis. Our results demonstrated a moderate diagnostic performance of MRI to detect biceps tears, with sensitivities between 71.1% and 73.3%, specificities of 72.7% and accuracy between 72 and 73%. Interobserver reproducibility was substantial (Kappa coefficient ranged from 0.62 to 0.69), and intraobserver reproducibility was substantial or almost perfect (Kappa coefficient ranged from 0.74 to 0.82). There was moderate correlation between the methods when classifying the type of tear (Kappa coefficient ranged from 0.38 to 0.47). Regarding full-thickness tears, specificities were calculated between 75.0% and 95.7%, but sensitivities from 55.6% to 66.7%. For the diagnosis of instability, sensitivity was from 52.4% to 59.1%, specificity was from 70.5% to 84% and accuracy was from 64,4% to 69,5%. The combined evaluation of tendon displacement and rotator cuff tears resulted in sensitivities from 17.5% to 47.7% and specificities from 72.7% to 90.7%. Interobserver reproducibility was substantial (Kappa coefficient ranged from 0.59 to 0.7), and intraobserver reproducibility was substantial or almost perfect (Kappa coefficient ranged from 0.76 to 0.80) for instability assessment. We did not identify predictive factors for magnetic resonance imaging accuracy in the assessment of these conditions
60

Validação do questionário de angina da OMS na sua versão curta utilizando como padrão ouro o teste de esforço e o ecocardiograma sob estresse farmacológico / Validation of the angina questionnaire of the oms on the short version using as gold standard the exercise treadmill test and the pharmacological stress echocardiography

Bastos, Maria do Socorro Castelo Branco de Oliveira 06 August 2010 (has links)
OBJETIVO: Avaliar a validade da versão curta do questionário de angina da OMS/Rose em português, em adultos de 40 a 74 anos, moradores do Butantã, área de referência do Hospital Universitário da Universidade de São Paulo, Brasil usando como padrão-ouro o teste ergométrico e o ecocardiograma sob estresse farmacológico. Analisar ainda se a associação do questionário de dispnéia da American Thoracic Society ao questionário de angina da OMS/Rose altera a sensibilidade, especificidade, valor preditivo positivo (VPP) e negativo (VPN), a razão de verossimilhança positiva (RVP) e negativa (RVN). MÉTODOS: A versão curta do questionário de angina, traduzida e adaptada para o português, consiste das três primeiras perguntas que caracterizam dor no peito aos esforços e foi aplicada a 116 pessoas classificadas como de baixo e alto risco, de acordo com o escore de Framingham, utilizando como padrão-ouro o teste ergométrico Em um subgrupo de 74 participantes foi utilizado o ecocardiograma sob estresse farmacológico como padrão-ouro. Foram calculados a sensibilidade, especificidade, acurácia, VPP, VPN, RVP, RVN.. O PRIME-MD foi usado para diagnóstico de ansiedade e depressão. Utilizou-se o questionário de dispnéia da American Thoracic Society (ATS) traduzido RESULTADOS: A frequência de angina foi de 8,7%, similar a outros estudos e, de isquemia 4,8% semelhante à população geral do município de São Paulo. Dentre 126 participantes, 116 pessoas apresentaram um teste de esforço conclusivo, sendo 44 do grupo de alto risco, escore de Framingham médio 9,3 (2,5) com idade média 53,6 (7,0) anos, mais altos quando comparados aos 72 do grupo de baixo risco com escore de 3,3 (3,0) (p=0,000) e idade 49,2 (7,3) anos (p=0,002). No grupo de baixo risco ocorreu a maioria dos casos de isquemia. Dos 126 participantes, 88 foram submetidos ao ecocardiograma sob estresse e ele foi conclusivo em 74, 29 pessoas no grupo de alto risco apresentaram um escore médio de Framingham de 9.4 (2.7) e 45 do grupo de baixo risco com escore de 3.4 (3.4) (p=0.000).O questionário de angina comparado ao teste ergométrico apresentou sensibilidade de 25,0%, especificidade de 92,0%, acurácia de 89,7%, VPP de 10,0%, VPN de 97,2%, RVP de 3,1 e RVN de 0,82. Não houve nenhum caso de isquemia ao ecocardiograma sob estresse associado ao questionário de angina positivo. A freqüência de ansiedade foi 18,3% e de depressão 13,5% mas, houve associação entre presença de depressão ou ansiedade definida pelo questionário com presença de angina avaliada pelo questionário de angina da OMS/Rose (p=0,076). Nenhum participante com dispnéia apresentou sinais de isquemia aos exames. CONCLUSÃO: A versão curta do questionário de angina traduzida para o português tem parâmetros de qualidade de teste similar aos encontrados em outros estudos em amostras maiores, ou seja, baixa sensibilidade e alta especificidade, e sua utilização depende dos objetivos do estudo. Os transtornos mentais estudados se associaram com a positividade ao questionário de angina. Dispnéia não foi um sintoma equivalente de isquemia miocárdica na amostra estudada / OBJECTIVE: To assess the validity of the short version of the WHO/Rose angina questionnaire in Portuguese, applied to adults aged 40-74 years, living at Butantã, reference area of the Hospital Universitário - Universidade de São Paulo, in Brazil using exercise treadmill test and pharmacological stress echocardiography as gold standard. To analyze if the association of the American Thoracic Society (ATS) dyspnea questionnaire to the WHO/Rose angina questionnaire modifies de sensitivity, specificity, accuracy, positive (PPV) and negative (NPV) predictive values, positive (PLR) and negative (NLR) likelihood ratios. METHODS: The short version of the angina questionnaire adapted and translated into Portuguese has three first questions to characterize exertional chest pain. It was applied to 116 individuals classified into low- and high-risks groups according to the Framingham score, using the exercise treadmill test as the gold standard. Pharmacological stress echocardiography was used as the gold standard in a group of 74 participants. Sensibility, specificity, accuracy, PPV, NPV, PLR and NLR were calculated. The PRIME-MD was used to diagnose anxiety and depression. The translated version of the dyspnea questionnaire of the American Thoracic Society (ATS) was also employed. RESULTS: The frequency of angina was 8.7%, similar to that found in other studies, and of 4.8% for ischemia, which is similar to the general population of the city of Sao Paulo. Among 126 participants, 116 individuals had a conclusive exercise treadmill test; 44 subjects in the high-risk group had a mean Framingham score of 9.3 (2.5) and mean age of 53.6 (7.0) years these figures are higher as compared to 72 individuals of the low-risk group, with a score of 3.3 (3.0) (p=0.000) and mean age of 49.2 (7.3) years (p=0.002). Most cases of ischemia were in the low-risk group. Out of 126 participants, 88 were submitted to the stress echocardiography and it was conclusive in 74, 29 subjects in the high-risk group had a mean Framingham score of 9.4 (2.7) and 45 of the low-risk group had a score of 3.4 (3.4) (p=0.000). The angina questionnaire was compared to the exercise treadmill test and presented sensibility of 25.0%, specificity of 92.0%, accuracy of 89.7%, PPV of 10.0%, NPV of 97.2%, PLR of 3.1 and NLR of 0.82. There was no case of ischemia on stress echocardiography associated to a positive angina questionnaire. The frequency of anxiety was 18.3% and of depression was 13.5%, there was association among presence of the depression and anxiety as questionnaire defined with angina presence the assessed by the OMS/Rose angina questionnaire (p=0.076). No participant with dyspnea presented signs of ischemia on exams. CONCLUSION: The short version of the angina questionnaire translated into Portuguese has quality parameters of test that are similar to those of other studies with larger samples, that is, low sensibility and high specificity and its utilization depends on the study objectives. The mental disorders assessed were associated with positive angina questionnaire. Dyspnea was not a myocardial ischemia equivalent symptom in studied sample

Page generated in 0.1941 seconds