• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 741
  • 15
  • 10
  • 8
  • 8
  • 8
  • 4
  • 4
  • 2
  • Tagged with
  • 762
  • 357
  • 326
  • 262
  • 259
  • 243
  • 242
  • 239
  • 191
  • 178
  • 151
  • 141
  • 134
  • 132
  • 130
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Dexmedetomidina associada à ropivacaína em anestesia locorregional para analgesia trans e pós-operatória em procedimentos cirúrgicos de joelho em cães

Mombachi, Verônica Santos January 2015 (has links)
Bloqueios regionais periféricos têm sido frequentemente utilizados em uma variedade de procedimentos na rotina veterinária, para promover analgesia durante e após as cirurgias. Ropivacaína é um anestésico local de longa ação e farmacologicamente semelhante à bupivacaína, porém parece oferecer margem de segurança maior e menor cardiotoxicidade em comparação com a bupivacaína. A dexmedetomidina é um agonista α2-adrenérgico altamente seletivo para receptores α2. Estudos utilizando ratos como modelo experimental e diferentes doses de dexmedetomidina adicionada à bupivacaína ou ropivacaína, demonstraram prolongar a ação sensitiva e motora da anestesia periférica do nervo ciático. Em pacientes humanos, este efeito também foi comprovado. O presente trabalho testou a hipótese de que a dexmedetomidina associada à ropivacaína aumentaria o bloqueio sensitivo quando comparada à ropivacaína ou bupivacaína sem adjuvante, na anestesia periférica do membro pélvico de cães submetidos a cirurgias ortopédicas de joelho. Um total de 25 cães (três para estudo piloto) que foram submetidos a cirurgias de ruptura de ligamento cruzado cranial ou luxação de patela foram selecionados. Os dois principais nervos do plexo lombossacral (femoral e ciático) foram identificados através de neuroestimulação. 22 cães foram randomizados em um dos três grupos. No grupo ROPI (n=7) 0,2 ml.kg-1 de ropivacaína 0,75%, no grupo BUPI (n=7) 0,2 ml.kg-1 de bupivacaína 0,5% e no grupo ROPIDEX (n=8) 0,2 ml.kg-1 de ropivacaína 0,75% + dexmedetomidina 0,5 mcg.ml-1 de solução anestésica foram administrados. Inicio do bloqueio sensitivo, duração dos bloqueios, duração da analgesia e a estimativa de dor foram registrados. Características dos cães e tipo de cirurgia foram semelhantes entre os grupos. O inicio do bloqueio sensitivo foi similar entre os grupos (P= 0,102). A duração da ação sensitiva foi significativamente maior no grupo ROPIDEX (645 ±127,3 minutos) em comparação aos grupos ROPI (440±65,3 minutos) e BUPI (502±105,5 minutos) P= 0,004. O grupo ROPIDEX também teve a ação motora mais longa que o grupo ROPI (P= 0,035), 540±160 e 365±96 minutos respectivamente. A analgesia foi mais duradoura no grupo ROPIDEX (720 ±150 minutos) em comparação aos grupos ROPI (437±107 minutos) e BUPI (541±105 minutos) - P= 0,001. Não houve diferença significativa nas avaliações de dor entre os grupos nos momentos comparados. Um animal do grupo ROPIDEX apresentou bradicardia após a realização do bloqueio. Durante o período transanestésico o grupo ROPIDEX apresentou valores de pressão significativamente mais baixos nos momentos T3 e T5, mas nenhum paciente apresentou hipotensão. Bloqueio do membro contralateral foi observado em 1 caso (4,5%) no grupo ROPIDEX. Três pacientes (2 no grupo BUPI e 1nogrupo ROPIDEX ) tiveram que receber analgesia complementar com fentanil no período cirúrgico, 86% dos cães foi resgatado apenas após a recuperação total da anestesia local. Concluiu-se que o uso de dexmedetomidina associada à ropivacaína para a anestesia regional periférica dos nervos femoral e ciático prolonga a duração dos bloqueios sensitivo e motor e também da analgesia pós-operatória de procedimentos ortopédicos em joelhos de cães. / Peripheral nerve blocks are used frequently in a variety of procedures in veterinary practice for surgical anesthesia and postoperative pain. Ropivacaine is a local anesthetic with long duration, having similar pharmacology to bupivacaine; however, it has a wider safety margin and was shown to possess less cardiotoxicity in comparison with bupivacaine. Many additives to local anesthetics have been investigated in attempt to increase the duration of the block in order to improve postoperative pain. Dexmedetomidine is a α2-receptor agonist highly selective. Previous studies showed that different doses of dexmedetomidine enhanced the duration of sensory and motor blockade when added to bupivacaine and ropivacaine in a sciatic nerve block model in rat. In humans this results also has been reported. The present tested the hypothesis that dexmedetomidine added to ropivacaine, when compared to ropivacaine or bupivacaine alone, enhances the duraction of sensory blockade for peripheral femoral and sciatic nerve block for knee surgeries in dogs. 22 patients scheduled for elective hind limb surgery were divided into three goups in a randomized fashion. The two main nerves of the lumbosacral plexus (femoral and sciatic) were identified using neural stimulation. Pacients were assigned to one of the three group. In group ROPI (n=7) 0,2 ml.kg-1 of ropivacaine 0,75%, in group BUPI 0,2 ml.kg-1of bupivacaine 0,5% and in group ROPIDEX 0,2 ml.kg-1+0,5 mcg.ml-1of anesthetic solution were given. Sensory block onsetime, motor and sensory block duration and duration of analgesia were recorded. Demographic data and surgical characteristics were similar in all groups. Sensory block onset time were not different between groups (P= 0,102). Sensory block duration were longer in ROPIDEX group (645 ±127,3 minutes) than ROPI (440±65,3 minutes) or BUPI (502±105,5 minutes) (P= 0,004). Motor block duration were longer in ROPIDEX than ROPI (P= 0,035), 540±160 e 365±96 minutos respectively, but not differ from BUPI. Duration of analgesia was longer in ROPIDEX group (720 ±150 minutes) when compared to ROPI (437±107 minutes) or BUPI (541±105 minutes) (P=0,001). There were no different between pain score evaluation among groups. One dog had bradycardia after peripheral block with ROPIDEX and during the anesthetic period arterial pressure levels were lower at T3 and T5 moments, but without hypotension. Contralateral hind limb block was present in one case (4,5%)in ROPIDEX group. Three dogs needed additional analgesia (2 in BUPI and 1 in ROPIDEX) during surgery while 86% of patients received rescue analgesia only when totally recovered from local anesthesia. It was concluded that dexmedetomidine added to ropivacaine for lateral pre-iliac and paravertebral lumbosacral plexus block prolongs the duration the block and the duration of postoperative analgesia in dogs undergoing pelvic limbs orthopedic surgery.
92

Dexmedetomidina associada à ropivacaína em anestesia locorregional para analgesia trans e pós-operatória em procedimentos cirúrgicos de joelho em cães

Mombachi, Verônica Santos January 2015 (has links)
Bloqueios regionais periféricos têm sido frequentemente utilizados em uma variedade de procedimentos na rotina veterinária, para promover analgesia durante e após as cirurgias. Ropivacaína é um anestésico local de longa ação e farmacologicamente semelhante à bupivacaína, porém parece oferecer margem de segurança maior e menor cardiotoxicidade em comparação com a bupivacaína. A dexmedetomidina é um agonista α2-adrenérgico altamente seletivo para receptores α2. Estudos utilizando ratos como modelo experimental e diferentes doses de dexmedetomidina adicionada à bupivacaína ou ropivacaína, demonstraram prolongar a ação sensitiva e motora da anestesia periférica do nervo ciático. Em pacientes humanos, este efeito também foi comprovado. O presente trabalho testou a hipótese de que a dexmedetomidina associada à ropivacaína aumentaria o bloqueio sensitivo quando comparada à ropivacaína ou bupivacaína sem adjuvante, na anestesia periférica do membro pélvico de cães submetidos a cirurgias ortopédicas de joelho. Um total de 25 cães (três para estudo piloto) que foram submetidos a cirurgias de ruptura de ligamento cruzado cranial ou luxação de patela foram selecionados. Os dois principais nervos do plexo lombossacral (femoral e ciático) foram identificados através de neuroestimulação. 22 cães foram randomizados em um dos três grupos. No grupo ROPI (n=7) 0,2 ml.kg-1 de ropivacaína 0,75%, no grupo BUPI (n=7) 0,2 ml.kg-1 de bupivacaína 0,5% e no grupo ROPIDEX (n=8) 0,2 ml.kg-1 de ropivacaína 0,75% + dexmedetomidina 0,5 mcg.ml-1 de solução anestésica foram administrados. Inicio do bloqueio sensitivo, duração dos bloqueios, duração da analgesia e a estimativa de dor foram registrados. Características dos cães e tipo de cirurgia foram semelhantes entre os grupos. O inicio do bloqueio sensitivo foi similar entre os grupos (P= 0,102). A duração da ação sensitiva foi significativamente maior no grupo ROPIDEX (645 ±127,3 minutos) em comparação aos grupos ROPI (440±65,3 minutos) e BUPI (502±105,5 minutos) P= 0,004. O grupo ROPIDEX também teve a ação motora mais longa que o grupo ROPI (P= 0,035), 540±160 e 365±96 minutos respectivamente. A analgesia foi mais duradoura no grupo ROPIDEX (720 ±150 minutos) em comparação aos grupos ROPI (437±107 minutos) e BUPI (541±105 minutos) - P= 0,001. Não houve diferença significativa nas avaliações de dor entre os grupos nos momentos comparados. Um animal do grupo ROPIDEX apresentou bradicardia após a realização do bloqueio. Durante o período transanestésico o grupo ROPIDEX apresentou valores de pressão significativamente mais baixos nos momentos T3 e T5, mas nenhum paciente apresentou hipotensão. Bloqueio do membro contralateral foi observado em 1 caso (4,5%) no grupo ROPIDEX. Três pacientes (2 no grupo BUPI e 1nogrupo ROPIDEX ) tiveram que receber analgesia complementar com fentanil no período cirúrgico, 86% dos cães foi resgatado apenas após a recuperação total da anestesia local. Concluiu-se que o uso de dexmedetomidina associada à ropivacaína para a anestesia regional periférica dos nervos femoral e ciático prolonga a duração dos bloqueios sensitivo e motor e também da analgesia pós-operatória de procedimentos ortopédicos em joelhos de cães. / Peripheral nerve blocks are used frequently in a variety of procedures in veterinary practice for surgical anesthesia and postoperative pain. Ropivacaine is a local anesthetic with long duration, having similar pharmacology to bupivacaine; however, it has a wider safety margin and was shown to possess less cardiotoxicity in comparison with bupivacaine. Many additives to local anesthetics have been investigated in attempt to increase the duration of the block in order to improve postoperative pain. Dexmedetomidine is a α2-receptor agonist highly selective. Previous studies showed that different doses of dexmedetomidine enhanced the duration of sensory and motor blockade when added to bupivacaine and ropivacaine in a sciatic nerve block model in rat. In humans this results also has been reported. The present tested the hypothesis that dexmedetomidine added to ropivacaine, when compared to ropivacaine or bupivacaine alone, enhances the duraction of sensory blockade for peripheral femoral and sciatic nerve block for knee surgeries in dogs. 22 patients scheduled for elective hind limb surgery were divided into three goups in a randomized fashion. The two main nerves of the lumbosacral plexus (femoral and sciatic) were identified using neural stimulation. Pacients were assigned to one of the three group. In group ROPI (n=7) 0,2 ml.kg-1 of ropivacaine 0,75%, in group BUPI 0,2 ml.kg-1of bupivacaine 0,5% and in group ROPIDEX 0,2 ml.kg-1+0,5 mcg.ml-1of anesthetic solution were given. Sensory block onsetime, motor and sensory block duration and duration of analgesia were recorded. Demographic data and surgical characteristics were similar in all groups. Sensory block onset time were not different between groups (P= 0,102). Sensory block duration were longer in ROPIDEX group (645 ±127,3 minutes) than ROPI (440±65,3 minutes) or BUPI (502±105,5 minutes) (P= 0,004). Motor block duration were longer in ROPIDEX than ROPI (P= 0,035), 540±160 e 365±96 minutos respectively, but not differ from BUPI. Duration of analgesia was longer in ROPIDEX group (720 ±150 minutes) when compared to ROPI (437±107 minutes) or BUPI (541±105 minutes) (P=0,001). There were no different between pain score evaluation among groups. One dog had bradycardia after peripheral block with ROPIDEX and during the anesthetic period arterial pressure levels were lower at T3 and T5 moments, but without hypotension. Contralateral hind limb block was present in one case (4,5%)in ROPIDEX group. Three dogs needed additional analgesia (2 in BUPI and 1 in ROPIDEX) during surgery while 86% of patients received rescue analgesia only when totally recovered from local anesthesia. It was concluded that dexmedetomidine added to ropivacaine for lateral pre-iliac and paravertebral lumbosacral plexus block prolongs the duration the block and the duration of postoperative analgesia in dogs undergoing pelvic limbs orthopedic surgery.
93

Dexmedetomidina associada à ropivacaína em anestesia locorregional para analgesia trans e pós-operatória em procedimentos cirúrgicos de joelho em cães

Mombachi, Verônica Santos January 2015 (has links)
Bloqueios regionais periféricos têm sido frequentemente utilizados em uma variedade de procedimentos na rotina veterinária, para promover analgesia durante e após as cirurgias. Ropivacaína é um anestésico local de longa ação e farmacologicamente semelhante à bupivacaína, porém parece oferecer margem de segurança maior e menor cardiotoxicidade em comparação com a bupivacaína. A dexmedetomidina é um agonista α2-adrenérgico altamente seletivo para receptores α2. Estudos utilizando ratos como modelo experimental e diferentes doses de dexmedetomidina adicionada à bupivacaína ou ropivacaína, demonstraram prolongar a ação sensitiva e motora da anestesia periférica do nervo ciático. Em pacientes humanos, este efeito também foi comprovado. O presente trabalho testou a hipótese de que a dexmedetomidina associada à ropivacaína aumentaria o bloqueio sensitivo quando comparada à ropivacaína ou bupivacaína sem adjuvante, na anestesia periférica do membro pélvico de cães submetidos a cirurgias ortopédicas de joelho. Um total de 25 cães (três para estudo piloto) que foram submetidos a cirurgias de ruptura de ligamento cruzado cranial ou luxação de patela foram selecionados. Os dois principais nervos do plexo lombossacral (femoral e ciático) foram identificados através de neuroestimulação. 22 cães foram randomizados em um dos três grupos. No grupo ROPI (n=7) 0,2 ml.kg-1 de ropivacaína 0,75%, no grupo BUPI (n=7) 0,2 ml.kg-1 de bupivacaína 0,5% e no grupo ROPIDEX (n=8) 0,2 ml.kg-1 de ropivacaína 0,75% + dexmedetomidina 0,5 mcg.ml-1 de solução anestésica foram administrados. Inicio do bloqueio sensitivo, duração dos bloqueios, duração da analgesia e a estimativa de dor foram registrados. Características dos cães e tipo de cirurgia foram semelhantes entre os grupos. O inicio do bloqueio sensitivo foi similar entre os grupos (P= 0,102). A duração da ação sensitiva foi significativamente maior no grupo ROPIDEX (645 ±127,3 minutos) em comparação aos grupos ROPI (440±65,3 minutos) e BUPI (502±105,5 minutos) P= 0,004. O grupo ROPIDEX também teve a ação motora mais longa que o grupo ROPI (P= 0,035), 540±160 e 365±96 minutos respectivamente. A analgesia foi mais duradoura no grupo ROPIDEX (720 ±150 minutos) em comparação aos grupos ROPI (437±107 minutos) e BUPI (541±105 minutos) - P= 0,001. Não houve diferença significativa nas avaliações de dor entre os grupos nos momentos comparados. Um animal do grupo ROPIDEX apresentou bradicardia após a realização do bloqueio. Durante o período transanestésico o grupo ROPIDEX apresentou valores de pressão significativamente mais baixos nos momentos T3 e T5, mas nenhum paciente apresentou hipotensão. Bloqueio do membro contralateral foi observado em 1 caso (4,5%) no grupo ROPIDEX. Três pacientes (2 no grupo BUPI e 1nogrupo ROPIDEX ) tiveram que receber analgesia complementar com fentanil no período cirúrgico, 86% dos cães foi resgatado apenas após a recuperação total da anestesia local. Concluiu-se que o uso de dexmedetomidina associada à ropivacaína para a anestesia regional periférica dos nervos femoral e ciático prolonga a duração dos bloqueios sensitivo e motor e também da analgesia pós-operatória de procedimentos ortopédicos em joelhos de cães. / Peripheral nerve blocks are used frequently in a variety of procedures in veterinary practice for surgical anesthesia and postoperative pain. Ropivacaine is a local anesthetic with long duration, having similar pharmacology to bupivacaine; however, it has a wider safety margin and was shown to possess less cardiotoxicity in comparison with bupivacaine. Many additives to local anesthetics have been investigated in attempt to increase the duration of the block in order to improve postoperative pain. Dexmedetomidine is a α2-receptor agonist highly selective. Previous studies showed that different doses of dexmedetomidine enhanced the duration of sensory and motor blockade when added to bupivacaine and ropivacaine in a sciatic nerve block model in rat. In humans this results also has been reported. The present tested the hypothesis that dexmedetomidine added to ropivacaine, when compared to ropivacaine or bupivacaine alone, enhances the duraction of sensory blockade for peripheral femoral and sciatic nerve block for knee surgeries in dogs. 22 patients scheduled for elective hind limb surgery were divided into three goups in a randomized fashion. The two main nerves of the lumbosacral plexus (femoral and sciatic) were identified using neural stimulation. Pacients were assigned to one of the three group. In group ROPI (n=7) 0,2 ml.kg-1 of ropivacaine 0,75%, in group BUPI 0,2 ml.kg-1of bupivacaine 0,5% and in group ROPIDEX 0,2 ml.kg-1+0,5 mcg.ml-1of anesthetic solution were given. Sensory block onsetime, motor and sensory block duration and duration of analgesia were recorded. Demographic data and surgical characteristics were similar in all groups. Sensory block onset time were not different between groups (P= 0,102). Sensory block duration were longer in ROPIDEX group (645 ±127,3 minutes) than ROPI (440±65,3 minutes) or BUPI (502±105,5 minutes) (P= 0,004). Motor block duration were longer in ROPIDEX than ROPI (P= 0,035), 540±160 e 365±96 minutos respectively, but not differ from BUPI. Duration of analgesia was longer in ROPIDEX group (720 ±150 minutes) when compared to ROPI (437±107 minutes) or BUPI (541±105 minutes) (P=0,001). There were no different between pain score evaluation among groups. One dog had bradycardia after peripheral block with ROPIDEX and during the anesthetic period arterial pressure levels were lower at T3 and T5 moments, but without hypotension. Contralateral hind limb block was present in one case (4,5%)in ROPIDEX group. Three dogs needed additional analgesia (2 in BUPI and 1 in ROPIDEX) during surgery while 86% of patients received rescue analgesia only when totally recovered from local anesthesia. It was concluded that dexmedetomidine added to ropivacaine for lateral pre-iliac and paravertebral lumbosacral plexus block prolongs the duration the block and the duration of postoperative analgesia in dogs undergoing pelvic limbs orthopedic surgery.
94

Metodologia para implementação do MPS.BR utilizando o ambiente webapsee

ROCHA, Vanderlene Covre 29 April 2009 (has links)
Submitted by Irvana Coutinho (irvana@ufpa.br) on 2011-03-30T16:38:01Z No. of bitstreams: 2 ROCHA, Vanderlene Covre PPGEngenharia Elétrica.pdf: 2493637 bytes, checksum: ac14f60ec89cf61fb6b7fd05ccdbf266 (MD5) license_rdf: 22876 bytes, checksum: 0a4e855daae7a181424315bc63e71991 (MD5) / Made available in DSpace on 2011-03-30T16:38:01Z (GMT). No. of bitstreams: 2 ROCHA, Vanderlene Covre PPGEngenharia Elétrica.pdf: 2493637 bytes, checksum: ac14f60ec89cf61fb6b7fd05ccdbf266 (MD5) license_rdf: 22876 bytes, checksum: 0a4e855daae7a181424315bc63e71991 (MD5) Previous issue date: 2009 / Eletronorte - Centrais Elétricas do Norte do Brasil S/A / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / A number of initiatives to improve the software process has emerged recently to improve quality and productivity in software organizations. Some models and standards have focused the implementation of improvements in the software development process area; MPS.BR model is an example of thiese models. This process improvement model aims to improve software quality, preferably for micro, small and medium enterprises in order to meet the needs of their business model and was chosen to be explored in this work. Several advantages are gained during process improvement effort, one of them is the definition of a systematic process for software development, which helps to achieve the process quality and productivity and also the developed product quality. The use of a defined process model brings several benefits associated with standardization, such as the optimization, the re-work cost reduction, less defects in products, among others. But there is a lack of models that can be applied directly to a specific company of software development and therefore it is necessary to model the process, customizing it with the ultimate goal of creating a model that adequately represents the organization process. One of the difficulties for the implementation of models such as MPS.BR is the lack of methodologies that shows how the implementation of improvements to be made and not only what should be done. In this context, this work proposes a methodology for the implementation of the MPS.BR model based on IDEAL model, through a specific tool, called WebAPSEE, which works to coordinate the methodology execution. The methodology was tested in a local organization called CTIC - Center for Information Technology and Communication of UFPA which was assessed as level of G MPS.BR. / Uma série de iniciativas para melhoria do processo de software surgiu recentemente visando melhorar a qualidade e a produtividade em organizações de desenvolvimento de software. Alguns modelos e normas têm buscado a implantação de melhorias no processo de desenvolvimento de software, o MPS.BR é um deles. Esse modelo de melhoria de processo é voltado para as micro, pequenas e médias empresas, de forma a atender as suas necessidades de negócio e foi o modelo escolhido para ser explorado nesse trabalho. Várias são as vantagens adquiridas com a implantação de um modelo de melhoria, umas delas é a definição de um processo sistemático de desenvolvimento de software, que auxilie tanto na qualidade e produtividade do processo quanto na qualidade do produto desenvolvido. Com um modelo de processo definido a organização pode contar com diversos benefícios associados à padronização, como, por exemplo, a otimização, a redução de custos com retrabalho, a redução de defeitos nos produtos, dentre outros. Mas não existem modelos prontos que possam ser aplicados diretamente a uma empresa específica de desenvolvimento de software e, por isso, é necessário modelar o processo, customizando-o, com o objetivo final de gerar um modelo que adequadamente represente o processo da organização. Uma das dificuldades para a implantação de modelos como o MPS.BR é a falta de metodologia que mostre como a implantação de melhoria deve ser feita e não apenas o que deve ser feito. Este trabalho propõe uma metodologia para a implementação do modelo MPS.BR baseada no modelo de implantação IDEAL, através de uma ferramenta específica, chamada WebAPSEE. A metodologia foi experimentada no CTIC - Centro de Tecnologia da Informação e Comunicação da UFPA que ao final do trabalho foi avaliado Nível G do MPS.BR.
95

[en] A SPATIAL PARTITIONING HEURISTIC FOR AUTOMATIC ADJUSTMENT OF THE 3D NAVIGATION SPEED IN MULTISCALE VIRTUAL ENVIRONMENTS / [pt] UMA HEURÍSTICA DE PARTIÇÃO ESPACIAL PARA O AJUSTE AUTOMÁTICO DA VELOCIDADE DE NAVEGAÇÃO 3D EM AMBIENTES DE MULTIESCALA

HENRIQUE D ESCRAGNOLLE-TAUNAY 28 March 2018 (has links)
[pt] Com a evolução tecnológica, ambientes virtuais em 3D crescem continuamente em complexidade; este é o caso de ambientes multiescala, i.e., ambientes que contêm grupos de objetos com níveis de escala extremamente divergentes. Tal variação em escala dificulta a navegação interativa neste tipo de ambiente dado sua demanda repetitiva e não-intuitiva de ajustes em tanto velocidade quanto escala, levando em consideração os objetos que estão próximos ao observador, para garantir uma navegação estável e confortável. Esforços recentes tem sido desenvolvidos trabalhando com soluções fortemente baseadas na GPU que nem sempre podem ser viáveis dependendo da complexidade de uma cena. Nós apresentamos uma heurística de particionamento espacial para o ajuste automático de velocidade de navegação 3D em um ambiente multiescala virtual, minimizando o esforço computacional e transferindo este para a CPU, permitindo que a GPU possa focar na renderização. Nossa proposta descreve uma estratégia geométrica durante a fase de pré-processamento que nos permite estimar, em tempo real, qual é a menor distância entre o observador e o objeto mais próximo dele. A partir desta informação única, somos capazes de ajustar automaticamente a velocidade de navegação de acordo com a caraterística de escala da região na qual o observador se encontra. Com a informação topológica da cena obtida na fase de pré-processamento, somos capazes de responder, em tempo real, qual é o objeto mais próximo assim como o objeto visível mais próximo, que nos permite propor duas diferentes heurísticas de velocidade de navegação automática. Finalmente, com o objetivo de verificar o ganho de usabilidade alcançado com as abordagens propostas, foram realizados testes de usuário para avaliar a eficiência e precisão da navegação, assim como a satisfação subjetiva do usuário. Os resultados foram particularmente significantes ao demonstrar o ganho em precisão da navegação ao utilizar as abordagens propostas, tanto para usuários experientes quanto para leigos. / [en] With technological evolution, 3D virtual environments continuously increase in complexity; such is the case with multiscale environments, i.e., environments that contain groups of objects with extremely diverging levels of scale. Such scale variation makes it difficult to interactively navigate in this kind of environment since it demands repetitive and unintuitive adjustments in either velocity or scale, according to the objects that are close to the observer, in order to ensure a comfortable and stable navigation. Recent efforts have been developed working with heavy GPU based solutions that are not feasible depending on the complexity of the scene. We present a spatial partitioning heurístic for automatic adjustment of the 3D navigation speed in a multiscale virtual environment minimizing the workload and transferring it to the CPU, allowing the GPU to focus on rendering. Our proposal describes a geometric strategy during the preprocessing phase that allows us to estimate, in real-time phase, which is the shortest distance between the observer and the object nearest to him. From this unique information, we are capable to automatically adjusting the speed of navigation according to the characteristic scale of the region where the observer is. With the scene topological information obtained in a preprocessing phase, we are able to obtain, in real-time, the closest object and the visible objects, which allows us to propose two different heurístics for automatic navigation velocity. Finally, in order to verify the usability gain in the proposed approaches, user tests were conducted to evaluate the accuracy and echiency of the navigation, and users subjective satisfaction. Results were particularly significant for demonstrating accuracy gain in navigation while using the proposed approaches for both laymen and advanced users.
96

[en] TECHNICAL REGULATION: PROPOSITION OF A MINIMUM CODE OF THE GOOD REGULATORY PRACTICES AND DIAGNOSIS OF THE BRAZILIAN SYSTEM / [pt] REGULAMENTAÇÃO TÉCNICA: PROPOSIÇÃO DE UM CÓDIGO MÍNIMO DAS BOAS PRÁTICAS E DIAGNÓSTICO DO SISTEMA BRASILEIRO

JORGE KENEDY ALMEIDA SILVA 21 May 2007 (has links)
[pt] Objetivo: Proposição de um código mínimo das boas práticas da regulamentação técnica com vistas a disciplinar o desenvolvimento e a aplicação de regulamentos e assegurar que estes somente sejam introduzidos quando justificados com base em objetivos legítimos e em benefício da eficiência de qualquer sistema regulatório, com o propósito de evitar barreiras desnecessárias ao comércio e sem prejuízo dos interesses públicos. Motivação: Contribuir para o avanço do conhecimento sobre regulamentação técnica e para o aprimoramento das práticas regulatórias do sistema brasileiro, assim facilitando a inserção comercial do País em âmbito internacional. Contextualização: O trabalho se desenvolveu no contexto de um movimento mundial de harmonização de nomenclaturas e procedimentos regulatórios ainda em uso nos países membros da Organização Mundial do Comércio, reconhecendo-se, entretanto, que aspectos puramente técnicos não são capazes de justificar um modelo unificado. Metodologia: A proposição das boas práticas da regulamentação baseou-se: (i) na análise das características mínimas dos sistemas regulatórios em relação às recomendações da Organização Mundial do Comércio, do Código de Alfândega e de acordos comerciais regionais e internacionais de conceituados organismos; (ii) no diagnóstico da regulamentação técnica vigente no País à luz da prática internacional e na identificação dos diferentes atores que integram o sistema regulatório brasileiro; e (iii) na identificação dos aspectos funcionais e na eficácia do sistema regulatório brasileiro, por meio de pesquisa de campo conduzida junto aos 29 organismos que integram o referido sistema. Resultados: À luz da prática internacional, o trabalho identifica, discute e fundamenta um conjunto de nove parâmetros considerados essenciais às boas práticas da regulamentação, a saber: (i) aderência aos preceitos básicos e nomenclatura internacional; (ii) coordenação integrada do sistema nacional de regulamentação; (iii) sistemática para avaliação de riscos pela introdução ou não de um determinado regulamento técnico; (iv) infra-estrutura de comitês técnicos; (v) sistema nacional de normalização; (vi) sistema nacional de metrologia; (vii) infra-estrutura básica para avaliação da conformidade; (viii) redes de segurança do sistema regulatório e (ix) acompanhamento de mercado. Conclusões: A introdução de um código de boas práticas da regulamentação constitui pré-condição ao adequado funcionamento de qualquer sistema regulatório. Nove atributos essenciais foram caracterizados à luz da prática internacional como elementos que devem integrar um código mínimo capaz de proporcionar a harmonização entre os órgãos regulamentadores do país, a interação dos órgãos regulamentadores com o Ponto Focal Brasileiro, a promoção da cidadania, o desenvolvimento econômico e a redução dos impactos sócio- econômico-ambientalcultural da regulamentação técnica. / [en] Objectives: The aim of this study is to formalize a set of rules, principles and instruments to suit the purpose of a good technical regulatory practice that would discipline the development and application of technical regulations based on legitimate objectives oriented by public interests. Such framework is required for the benefit of an efficient regulatory system to avoid unnecessary barriers to trade and without loss of public interests. Motivation: To contribute to the advance of technical regulation and best regulatory practices in Brazil, as a strategy to promote the country internationally. Context: The study was developed in the context of a worldwide movement, coordinated by the WTO, to harmonize nomenclature and procedures and to develop good regulatory practices, recognizing that purely technical aspects are not suffice to justify an unified approach. Methodology: The good regulatory practice here proposed is based on: (i) a diagnosis of technical regulation in place (ii) a search of the minimum characteristics of the regulatory systems in the light of WTO recommendations and relevant commercial agreements and (iii) a review of the specialized literaure and an exploratory survey among the regulatory bodies to find out their functional and operational aspects. Results: In the light of international practices, this work identifies, discusses and establishes a set of guiding principles considered essential to good regulatory practice, namely: (i) adherence to basic precepts and international practices; (ii) risk assessment associated with the introduction or not of a specific regulation; (iii) integrated coordination of a national system of regulation; (iv) infra-structure of national committees; (v) a national system of standardization; (vi) a national system of metrology; (vii) basic infra-structure for conformity assessment; (viii) security networks for the regulatory system and (ix) market surveillance. Conclusions: The introduction of a code of regulatory practices constitutes a pre-condition to an adequate functioning of any regulatory system. In the light of the best international regulatory practices, nine essential attributes were identified to promote harmonization of the regulatory bodies and information exchange between them; citizenship; economic development and reduction of their cultural, environmental, economic and social impacts.
97

[en] FIBERSOIL PEELS FOR CONSTRUCTION: FROM CONSTRUCTIVE TRADITIONS OF THE COUNTRY MAN TO MAN`S LIVING SPACES IN THE CITY. PROPOSING THE FIBERSOIL AS A WAY TO INCORPORATE AERATION CONCEPTS TO HOUSING / [pt] O FIBROSOLO COMO PELE PARA CONSTRUÇÃO: DA TRADIÇÃO CONSTRUTIVA DO HOMEM DO CAMPO, AOS ESPAÇOS HABITADOS PELO HOMEM DA CIDADE. UM CONCEITO DE AERAÇÃO DAS MORADIAS A PARTIR DA APLICAÇÃO CONSTRUTIVA DE CASCAS, PLACAS E FOLHAS DE FIBROSOLO

FERNANDO BETIM PAES LEME 08 January 2009 (has links)
[pt] Esta tese trata da apropriação de princípios de respiração e permeabilidade seletiva dos materiais que constituem nossas moradias, a partir do uso do fibrosolo. A técnica de fibrosolo, derivada dos conhecimentos construtivos feitos com terra crua e habitualmente realizados no campo, é utilizada aqui em diversos experimentos com finalidade de promover a aproximação entre estes saberes tradicionais e a ocupação dos espaços urbanos. Sob esta ótica, seu aprimoramento a partir da metodologia desenvolvida no LILD da PUC-Rio, estabelece uma perspectiva de uso sustentável e adequado às condições de moradia das cidades. / [en] The thesis concerns the appropriation of breathing and selective permeability principles of materials applied in the construction of our houses, departing from the usage of fibersoil. The fibersoil technique, derived from constructive knowledge of the country that usually adopts raw clay, is investigated in a series of experiments intending to promote an interaction between this traditional know-how and the occupation of urban spaces. From this framework, the enhancement of the process, based on the methodology developed in PUC-Rios LILD - Laboratory of Investigation in Living Design, establishes a perspective of sustainable usage adequate to the citys housing conditions.
98

Estudo do mecanismo de ação da crotoxina em tumores mamários e avaliação do seu potencial radiofarmacêutico / STUDY OF CROTOXIN MECHANISM OF ACTION TO MAMMARY CARCINOMAS AND EVALUATION OF ITS POTENTIAL AS A RADIOPHARMACEUTICAL

Marina Bicalho Silveira 28 January 2010 (has links)
A Crotoxina, o principal componente do veneno de Crotalus durissus terrificus, vem sendo estudada desde 1938. É um complexo polipeptídico natural com grande potencial farmacológico especialmente por seu efeito antitumoral, propriedade que tem despertado o interesse para o diagnóstico e o tratamento do câncer. Entretanto, pouco se sabe sobre seu mecanismo de ação e os sítios com os quais interage em células tumorais. O câncer de mama é o segundo tipo de câncer mais freqüente no mundo e o mais comum entre as mulheres. Cerca de 30 a 60% dos tumores mamários apresentam expressão aumentada de receptores do fator de crescimento epidérmico (EGFR), uma proteína transmembrana que desencadeia a proliferação celular. A partir de dados da literatura mostrando que o efeito antitumoral da Crotoxina é mais potente em células que superexpressam EGFR, estabeleceu-se o objetivo deste trabalho: avaliar os efeitos citotóxicos desse polipeptídeo sobre os tumores de origem mamária MCF-7 (carcinoma humano) e Ehrlich (carcinoma murino ascítico) e realizar um estudo de interação molecular da Crotoxina com células de tumor de Ehrlich. Inicialmente, a Crotoxina foi radiomarcada com iodo-125 (125I-Crotoxina) e iodo-131 (131I-Crotoxina). Ensaios de saturação e competição foram realizados para caracterizar a interação da Crotoxina in vitro, enquanto que a interação in vivo foi avaliada através da biodistribuição e obtenção de imagens em tomografia por emissão de fóton único (SPECT) do composto radiomarcado em camundongos portadores de tumor de Ehrlich. Os resultados evidenciaram que o polipeptídeo apresentou um potente efeito citotóxico sobre as células de tumor de Ehrlich, com valor de DL50 in vitro (concentração do composto que produziu 50% de morte celular) próximo de 1 micromolar, mas não apresentou efeito significativo sobre a linhagem MCF-7. Alterações morfológicas nas células de tumor de Ehrlich tratadas com Crotoxina sugerem indução de morte celular programada. A interação da 125I-Crotoxina com as células de Ehrlich foi saturável com cerca de 70% de especificidade, com Kd= 24,98 nmol/L e Bmax= 16570 sítios/célula para sítios de baixa afinidade e com Kd= 0,06 nmol/L e Bmax=210 sítios/célula para sítios de alta afinidade. O polipeptídeo radiomarcado apresentou menor especificidade (cerca de 37%) para a linhagem MCF-7. O EGF competiu com 20% dos sítios específicos da 125I-Crotoxina indicando que Crotoxina e EGF compartilham parcialmente sítios específicos em células de Ehrlich. Através do estudo de biodistribuição, observou-se que houve captação significativa de 125I-Crotoxina no tumor (razão tumor/músculo esquelético de 18,55) no período de 3 horas após administração deste composto. As imagens SPECT também evidenciaram captação diferenciada pelo tumor, mostrando interação in vivo da 131I-Crotoxina com células de tumor de Ehrlich. O conjunto dos resultados sugere que Crotoxina apresenta potente efeito antitumoral sobre células de Ehrlich e que este efeito é devido pelo menos parcialmente à interação específica com sítios de alta e baixa afinidade. Os sítios de baixa afinidade se correlacionam com o EGFR e os de alta afinidade ainda necessitam de mais investigação para melhor caracterização. Estes resultados corroboram o potencial da Crotoxina como ferramenta para radiodiagnóstico capaz de diferenciar células tumorais. / Crotoxin, the main component of Crotalus durissus terrificus snake venom, has been studied since 1938. It is a natural polypeptidic complex with pharmacological potential because of its antitumoral properties wich has attracted great interest for diagnosis and therapy of oncological deseases. However, Crotoxin mechanism of action and sites of specific interaction on tumor cells are still misunderstood. Breast cancer is the second most frequent type in the world and the most common cancer in women. About 30 to 60% of mammary tumors overexpress epidermal growth factor receptor (EGFR), a transmembrane protein related to cell proliferation. Since literature has reported that Crotoxin antitumoral effect is more potent on cells with EGFR overexpression the objectives of this work were to evaluate Crotoxin cytotoxic effects on mammary tumor cells human breast carcinoma (MCF-7) and Ehrlich tumor cells (murine ascitics carcinoma), and to investigate the specific molecular interaction of Crotoxin on Ehrlich tumor cells. Inititally, Crotoxin was radiolabelled with iodine-125 (125I-Crotoxin) and iodine-131 (131I-Crotoxin). Saturation and competition assay were carried out to characterize Crotoxin in vitro interaction; Crotoxin biodistribution studies and single-photon emission computed tomography (SPECT) of mice bearing Ehrlich tumor have been evaluated to describe in vivo interaction. Our results showed that Crotoxin presented cytotoxic effect against Ehrlich with DL50 in vitro (concentration of compound which is lethal for 50% of cells) of about one micromolar, but did not present significative effect against MCF-7. Morphological alterations characteristic of apoptosis suggests programmed cell death. 125I-Crotoxin interaction with Ehrlich tumor cells was saturable with approximately 70% specificity, and presented Kd=24.98 nmol/L and Bmax=16,570 sites/cell for low affinity binding sites and Kd=0.06 nmol/L e Bmax=210 sites/cell high affinity binding sites; moreover, the radiolabeled polypeptide interaction showed low specificity toward to MCF-7 (37%). EGF reduced 20% of 125I-Crotoxin specific binding, so specific binding sites of Crotoxin on Ehrlich tumor cells partially overlap to EGFR. Crotoxin biodistribution studies showed significant uptake in the tumor paw (tumor/skeletal muscle ratio= 18.55), three hours after administration. SPECT imaging also showed tumor uptake confirming in vivo interaction with Ehrlich tumor cells. Crotoxin had an antitumoral effect on Ehrlich tumor cells and this action is due, at least partially, to the specific interaction with low and high affinity binding sites. Low affinity binding sites correlate EGFR and high affinity binding sites still need identification. These results confirm Crotoxin as a template for radiopharmaceutical design for cancer diagnosis and as a tool for cancer studies, increasing its biotechnological potential.
99

Avaliação da base metrologica para calibração dos sistemas dosimétricos em tomografia computadorizada / Evaluation of a metrological framework for calibrating dosimetric systems of computed tomography

Juliana Viégas Pereira 19 August 2011 (has links)
As grandezas dosimétricas utilizadas em tomografia computadorizada (TC) foram definidas com o objectivo de avaliar as doses de radiação no paciente para fins de otimização e para verificar o desempenho dos equipamentos de TC. Neste trabalho foi estabelecida uma base metrológica para implantação de um procedimento de calibração de sistemas utilizados para dosimetria na área de tomografia computadorizada. Esta base metrológica consistiu na verificação da confiabilidade dos sistemas dosimétricos, na reprodução das qualidades de radiação de referência para feixes de tomografia computadorizada e na implantação da metodologia de calibração de câmaras do tipo lápis e de dosímetros termoluminescentes com a avaliação das incertezas associadas. O trabalho foi realizado no Laboratório de Calibração de Dosímetros do Centro de Desenvolvimento da Tecnologia Nuclear (LCD/CDTN), seguindo as indicações do Technical Report Series No. 457, Dosimetry in Diagnostic Radiology: An International Code of Practice TRS457 da Agência Internacional de Energia Atômica (AIEA) de 2007 e da International Electrotechnical Commission, Medical Diagnostic X-ray Equipment Radiation Conditions for use in the determination of characteristics - IEC 61267 de 2005. Os resultados da confiabilidade dos sistemas padrões sugerem que os limites estabelecidos pela IEC 61674 podem estar inadequados para o uso de câmaras de ionização tipo lápis. As radiações de referência RQR e RQT foram estabelecidas dentro dos limites de tolerância de 0,485 à 0,515. A caracterização metrológica de dosímetros termoluminescentes (TL) tem uma importante função na medição de doses em pacientes submetidos a exames de radiodiagnóstico. Os dosímetros termoluminescentes foram calibrados e apresentaram uma incerteza expandida inferior a 25% demonstrando que estão em condições de serem utilizados na dosimetria de pacientes. A câmara de ionização 10X5-3CT foi calibrada no Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares (LCI /IPEN) e no Laboratório do CDTN os resultados dos coeficientes de calibração variaram de 0,3% à 1,3%; isto evidencia a coerência metrológica entre os procedimentos de calibração adotados, já que as diferenças estão dentro das incertezas expandidas de 3,0% e 3,34%, respectivamente. Ao ser comparado o procedimento adotado no CDTN com o procedimento sugerido pelo Código de Prática TRS 457 os resultados dos coeficientes de calibração da câmara lápis apresentaram uma variação de até 6 % e uma incerteza expandia de 2,08%. Os dados obtidos permitem concluir que a base metrológica foi implantada, porém, antes de fornecer o serviço de calibração para a comunidade estudos detalhados no procedimento e comparações adicionais são necessários. / The dosimetric quantities used in computed tomography (CT) were defined to assess radiation doses to the patient for optimization purposes and to verify the performance of CT equipment. This work established a metrological framework for implementing a calibration procedure of systems used for CT dosimetry. The framework was evaluated through the verification of the metrological reliability of dosimetric systems, the reproduction of the reference radiation beam qualities for computed tomography and the implementation of the calibration methodology of the pencil type ionization chambers and thermoluninescent (TL) dosimeters including the evaluation of related uncertainties. The study was conducted at the Laboratory for Calibration of Dosimeters of the Development Center of Nuclear Technology (LCD / CDTN), following the recommendations of the Technical Report Series No. 457, "Dosimetry in Diagnostic Radiology: An International Code of Practice" - TRS457, 2007, of the Agency International Atomic Energy Agency and the International Electrotechnical Commission, "Medical Diagnostic X-ray Equipment - Radiation conditions for use in the determination of characteristics" - IEC 61267, 2005. The results of the reliability of the standard systems suggested that the limits set by IEC 61674 may be unsuitable for the use of pencil type ionization chambers. The reference radiations RQR and RQT were established within the limits of tolerance 0.485 - 0.515. The metrological characterization of TL dosimeters has an important role in the measurement of doses in patients undergoing radiological examinations. The dosimeters were calibrated and showed an expanded uncertainty of less than 25% indicating that they are able to be used in patient dosimetry. The 10X5-3CT ionization chamber was calibrated in the Laboratory Calibration of Instruments of the Institute of Energy and Nuclear Research (LCI / IPEN) and in the CDTN Calibration Laboratory; the difference between the calibration coefficients ranged from 0.3% to 1.3%; this highlights the consistency between the metrological calibration procedures adopted, since differences are within the expanded uncertainties of 3.0% and 3.34%, respectively. The comparison between the calibration procedures adopted by CDTN and suggested by the IAEA TRS 457 Code of Practice showed that the calibration coefficients of the pencil type chamber had a variation of up to 6% with an expanded uncertainty of 2.08%. The obtained data showed that the metrological framework was established; however, detailed studies of the procedure and additional comparisons are still needed before providing calibration service for the community.
100

Avaliação do potencial de remoção de arsênio utilizando lemna minor L. (1753) / Arsenic removal potential assessment using lemna minor L. (1753)

Gimenes, Luana Lorca Sartoris 29 October 2015 (has links)
Arsênio é um dos contaminantes inorgânicos mais tóxicos conhecidos, mesmo em pequenas quantidades, e muitos problemas podem ocorrer com a exposição humana a ele. Assim, o uso de tecnologias adequadas e com baixo custo torna-se essencial para remover este contaminante do ambiente. A fitorremediação é uma técnica promissora que está ganhando maior atenção no meio científico, pois possui facilidade na implantação e resistência das plantas em capturar ou simplesmente neutralizar a ação de determinados compostos tóxicos da água, servindo como verdadeiros filtros “verdes”. O presente trabalho tem como objetivo avaliar a eficiência da macrófita Lemna minor na remoção de arsênio, verificando a seletividade da planta para as espécies inorgânicas de arsênio (III e V) e avaliar o melhor tempo de remoção. Para os experimentos, plantas saudáveis (aproximadamente 0,5 g de biomassa fresca) foram selecionadas e transferidas para béqueres contendo diferentes concentrações de cada forma de arsênio (50; 100; 200; 300; 400 e 500 µg L-1), em solução nutriente Steinberg diluído (50%). As concentrações de As na água e na biomassa das plantas foram determinadas utilizando-se um Espectrômetro de Absorção Atômica em Chama, com geração de hiretos. Por meio da determinação de As (III) na solução contendo a Lemna minor por até 64 horas, observou-se uma queda gradativa do sinal de absorbância do As na solução até o período de 48 horas. Em todas as concentrações analisadas obtiveram percentagem de remoção maior que 50%, sendo crescente em comparação a concentração inicial. Lemna minor foi eficiente para remoção de As (III) em solução em todas as concentrações e nas condições estudadas tendo como maior taxa de remoção o período de 48 horas. Em sua biomassa seca percebeu-se maior acumulo de As nas maiores concentrações testadas, a remoção então é mais eficiente quando é exposta a concentrações maiores do contaminante. Já para o As (V) não houve eficiência de remoção da solução em todas as concentrações testadas e também a análise da biomassa seca dessas plantas demonstraram que não houve grande acumulo de As nos tecidos. Esse resultado demonstra um potencial seletivo da planta para a remoção de As (III), espécies mais tóxica, podendo ser empregada para a determinação/remoção seletiva de arsênio. / Arsenic is one of the most toxic known inorganic contaminants, even in small concentratios, and many problems can occur with human exposure to it. Thus, the use of suitable technologies and at low cost becomes essential to remove this contaminant from the environment. One promising technique is the phytoremediation that is gaining more attention in the scientific community once it has ease of deployment and resistance of plants to capture or simply neutralize the action of certain toxic compounds of water, serving as a true “green” filter. This study aims to evaluate the efficiency of the macrophyte Lemna minor on the removal of arsenic, verifying the selectivity of the plant to its inorganic species (As III and As V) and the best removal time. For the experiments, healthy plants (approximately 0,5 g fresh weight) were selected and transferred to beakers containing different concentrations of arsenic forms (50; 100; 200; 300; 400 and 500 μg L-1) in Steinberg diluted nutrient solution (50%). The concentrations in the water and plant biomass were determined using an Atomic Absorption Spectrometer for Flame, with hydrides generating. Through the determination of As (III) in the solution containing the Lemna minor up to 64 hours, there was a gradual decrease of the absorbance signal in the solution within 48 hours. At all concentrations tested removal rates obtained percentage than 50%, increased compared with the initial concentration. Lemna minor was effective for removal of As (III) of the solution at all concentrations and under the conditions studied as having greater removal rate in the 48 hour period. In its dry biomass was noticed highen accumulation of the highest concentrations tested, then the removal is more efficient when it is exposed to higher concentrations of the contaminant. As for the As (V) no removal solution efficiency in all tested concentrations and also analysis of the dried biomass of these plants showed no accumulation of high concentration in tissue. This result demonstrates a selective potential of the plant for the removal of As (III), the most toxic species can be employed to determine / selective removal of arsenic.

Page generated in 0.0631 seconds