• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 109
  • 1
  • Tagged with
  • 110
  • 71
  • 59
  • 38
  • 30
  • 29
  • 25
  • 25
  • 24
  • 21
  • 19
  • 19
  • 17
  • 17
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Espectro do transtorno de ansiedade social: estudo de suas comorbidades psiquiátricas e associação com o prolapso de valva mitral / Social anxiety spectrum: study of this psychiatry comorbidities and the association with the mitral valve prolapse

Santos Filho, Alaor 16 November 2010 (has links)
Introdução: O transtorno de ansiedade social (TAS) é uma condição que pode ser muito incapacitante, com considerável sofrimento subjetivo, alta prevalência de comorbidades psiquiátricas e impacto negativo no funcionamento psicossocial. Entretanto, existem poucos dados na literatura sobre a possível extensão deste comprometimento nos indivíduos com sinais e sintomas subclínicos do TAS. Além disso, a discussão sobre a associação entre o prolapso de valva mitral (PVM) e os transtornos de ansiedade, particularmente com o transtorno de pânico e o TAS, existe já há cerca de três décadas, mas os resultados publicados não são suficientes para definitivamente estabelecer ou excluir a associação entre essas condições, com prevalências variando de 0 a 57%. Método: O delineamento metodológico envolveu duas etapas. Na primeira, as comorbidades psiquiátricas e o comprometimento no funcionamento psicossocial foram avaliados em 355 estudantes universitários que haviam sido diagnosticados previamente como TAS (n=141), TAS subclínico (n=92) ou controles (n=122). Na segunda etapa, um total de 232 voluntários diagnosticados como transtorno de pânico (n=41), TAS (n=89) ou controles (n=102) foram avaliados em ecocardiografia quanto ao PVM. Os exames foram realizados por dois cardiologistas que estavam cegos em relação ao diagnóstico psiquiátrico dos participantes. Foram obtidas medidas utilizando os critérios atuais e antigos para o diagnóstico de PVM, para permitir a comparação e generalização dos resultados. Resultados: A taxa de comorbidade com outros transtornos psiquiátricos foi de 71,6% no grupo TAS e de 50% nos sujeitos com TAS subclínico, ambos significativamente maiores que os controles (28,7%). A presença de comorbidades foi progressivamente maior de acordo com o subtipo e a gravidade do TAS. Quanto ao funcionamento psicossocial o grupo TAS apresentou maior comprometimento que os outros dois grupos em todos os domínios avaliados, e os sujeitos com TAS subclínico apresentaram valores intermediários. Na segunda etapa, os resultados demonstraram que não há diferenças estatísticas entre os grupos quanto à prevalência de PVM, seja pelos critérios ecocardiográficos atuais para o diagnóstico de PVM (visão longitudinal paraesternal: pânico=2,4%, TAS=4,5%, controles=1,0%) ou pelos critérios antigos (visão apical de 4-câmaras: pânico=2,4%, TAS=4,5%, controles=10,8%; modo-M: pânico=2,4%, TAS=6,7%, controles=4,9%). Também não houve diferenças significativas em relação a outras características morfológicas, como presença de regurgitação mitral, espessamento valvar ou presença de alongamento de cordoalhas. Conclusões: A prevalência de comorbidades psiquiátricas e o comprometimento no funcionamento psicossocial aumentam progressivamente ao longo do espectro de ansiedade social. O fato de o TAS subclínico apresentar considerável incapacidade e sofrimento em comparação com sujeitos controles justifica uma revisão na validade desses critérios diagnósticos. Por outro lado, não houve associação entre o transtorno de pânico ou o TAS com o PVM em nossos resultados, independente dos critérios diagnósticos utilizados, com prevalências compatíveis com a esperada na população geral. Dessa forma, é preciso desmistificar a relação entre essa alteração cardíaca e o transtorno de pânico e o TAS, pelas repercussões que pode ter para o paciente e em seu tratamento psiquiátrico. / Background: Social anxiety disorder (SAD) is a highly disabling condition that causes considerable subjective suffering. It has a high prevalence rate of psychiatric comorbidities and a negative impact on psychosocial functioning. However, few data are available in the literature about the possible extent of this impairment in individuals with subthreshold signs and symptoms of SAD. In addition, the discussion about the association between mitral valve prolapse (MVP) and anxiety disorders, especially panic disorder and SAD, has been going on for over three decades, but the published results are insufficient to establish or to exclude an association between these conditions, with reported prevalence rates ranging from 0% to 57%. Method: The methodological design involved two stages. In the first, psychiatric comorbidities and psychosocial functioning impairment were evaluated in 355 college students diagnosed with SAD (n=141), subthreshold SAD (n=92) or as healthy controls (n=122) in a previous study. In the second stage, a total of 232 volunteers previously diagnosed with panic disorder (n=41), SAD (n=89) or as healthy controls (n=102) underwent echocardiographic evaluation for MVP. The exams were performed by two cardiologists who were blind to the psychiatric diagnosis of the participants. Measurements based on current and earlier MVP diagnostic criteria were taken in order to permit the comparison and generalization of the results. Results: The rate of comorbidity with other psychiatric disorders was 71.6% in the SAD group and 50% in subjects with subthreshold SAD, both significantly greater than controls (28.7%). The presence of comorbidities increased progressively according to SAD subtype and severity. Concerning psychosocial functioning, the SAD group had greater impairment than the other two groups in all domains evaluated, and subjects with subthreshold SAD presented intermediate values. In the second stage, the results demonstrated that there were no statistically significant differences among the groups in terms of MVP prevalence, whether using current diagnostic criteria (long-axis view: panic=2.4%, SAD=4.5%, control=1.0%) or earlier criteria (apical four-chamber view: panic=2.4%, SAD=4.5%, control=10.8%; M-mode: panic=2.4%, SAD=6.7%, control=4.9%). Also, there were no significant differences regarding other morphological characteristics, such as presence of mitral regurgitation, mean valve thickness or elongation of chordae. Conclusions: The rates of psychiatric comorbidities and the psychosocial functioning impairment increase progressively along the spectrum of social anxiety. The fact that subthreshold SAD causes considerable disability and suffering in comparison with control subjects justifies a review of the validity of current diagnostic criteria. On the other hand, in this investigation no association between panic disorder or SAD and MVP was documented, regardless of the diagnostic criteria used, with prevalence rates similar to those reported for the general population. Thus, it seems necessary to demystify the relationship between this cardiac alteration and panic disorder and SAD in order to avoid unwanted influences for the patient and his psychiatric treatment.
72

Fatores associados à insuficiência moderada ou importante da valva atrioventricular esquerda no primeiro mês após correção de defeito de septo atrioventricular

Kozak, Marcelo Felipe 27 May 2011 (has links)
Submitted by Fabíola Silva (fabiola.silva@famerp.br) on 2016-06-27T14:52:30Z No. of bitstreams: 1 marcelofelipekozak_dissert.pdf: 986000 bytes, checksum: 7f262464a429e4df84692f32c1e38c0d (MD5) / Made available in DSpace on 2016-06-27T14:52:30Z (GMT). No. of bitstreams: 1 marcelofelipekozak_dissert.pdf: 986000 bytes, checksum: 7f262464a429e4df84692f32c1e38c0d (MD5) Previous issue date: 2011-05-27 / Introduction: One of the most often and important complications after surgical treatment of atrioventricular septal defects is the left atrioventricular valve insufficiency. So, this study was conducted to identify risk factors for moderate or severe left atrioventricular valve regurgitation within 30 days of surgical repair of atrioventricular septal defects at our center. Methods: This was a retrospective study in which we evaluated the results of 104 consecutive patients that were operated on at our practice between 2002 and 2010. The following associated factors were considered: age, weight, Down syndrome, grade of preoperative atrioventricular valve regurgitation, abnormalities on the atrioventricular valve and the use of annuloplasty. Patients were separated in two groups according to type of AVSD: group I (complete) and group II (incomplete – partial and transitional). Characteristics of the 53 patients of the group I: the median patient age at the time of repair was 6.7 months; the median weight was 5.3 Kg; 86.8% had Down syndrome; at the time of preoperative evaluation, there were 26 cases with moderate or severe atrioventricular valve regurgitation (49.1%); annuloplasty was perfored in 34%; abnormalities on the valve were found in 11.3% of the cases. Characteristics of the 51 patients of the group II: The median patient age at the time of repair was 4.1 years; the median weight was 13.4 Kg; 37.2% had Down syndrome; at the time of preoperative evaluation, there were 23 cases with moderate or grater LAVVR (45.1%); abnormalities on the AV valve were found in 17.6% of the cases; annuloplasty was performed in 21.6% of the patients. Results: Group I - At the time of post-operative evaluation, there were 21 cases with moderate or severe left atrioventricular valve regurgitation (39.6%). After performing a multivariate analysis, the only significant factor associated with these grades of insufficiency within 30 days of surgical correction of complete atrioventricular septal defect was the absence of Down syndrome (p = 0.03). Group II - At the time of postoperative evaluation, there were 12 cases with moderate or greater LAVVR (23.5%). During univariate analysis, only absence of Down syndrome was statistically significant (p = 0.02). However, after a multivariate analysis, none of the factors reached significance. Conclusion: Absence of Down syndrome proved to be associated with moderate or severe post-operative left atrioventricular valve regurgitation in patients with complete AVSD. However, none of the factors studied was determinant of a moderate or greater LAVVR within the first 30 days of repair of incomplete AVSD at our center. / Introdução: Uma das complicações mais frequentes e importantes do tratamento cirúrgico do defeito de septo atrioventricular (DSAV) é a insuficiência residual da valva atrioventricular esquerda, tanto nas formas totais, como parciais e transicionais. Dessa forma, esse estudo foi conduzido para identificar fatores de risco associados à insuficiência da valva atrioventricular esquerda (IVAVE) de grau moderado ou importante nos primeiros 30 dias após correção de defeito de DSAV. Métodos: Dados de 104 pacientes com DSAV operados entre 2002 e 2010 foram avaliados retrospectivamente, sendo estudados os seguintes fatores de risco: idade e peso no momento da correção, ausência de síndrome de Down, grau de insuficiência da valva atrioventricular (AV) antes da correção, anormalidades na valva AV e uso de anuloplastia. Os pacientes foram separados em dois grupos de acordo com o tipo de DSAV: grupo I (total) e grupo II (parcial e transicional). Características dos 53 pacientes do grupo I: a mediana da idade foi de 6,7 meses e a do peso de 5,3 Kg; 86,8% tinham síndrome de Down; antes da operação, 26 pacientes apresentavam insuficiência pelo menos moderada da valva AV (49.1%); anuloplastia foi realizada em 34% dos pacientes; anormalidades na valva AV foram encontradas em 11.3% dos casos. Características dos 51 pacientes do grupo II: a mediana da idade foi de 4,1 anos e a do peso de 13,4 Kg; 37,2% tinham síndrome de Down; antes da operação, 23 pacientes apresentavam IVAVE pelo menos moderada (45,1%); anormalidades na valva AV foram encontradas em 17,6% dos casos; anuloplastia foi realizada em 21,6% dos pacientes. Resultados: Grupo I – Após a correção cirúrgica, 21 casos apresentaram IVAVE pelo menos moderada (39,6%). Pela análise multivariada, o único fator associado com IVAVE pelo menos moderada no pós-operatório foi ausência de síndrome de Down (p = 0,03). Grupo II - Após a correção cirúrgica, 12 casos apresentaram IVAVE pelo menos moderada (23,5%). Pela análise univariada, apenas a ausência de síndrome de Down teve significância estatística (p = 0.02). Porém, após análise multivariada, nenhum dos fatores teve significância estatística. Conclusão: Ausência de síndrome de Down foi determinante de IVAVE moderada ou importante nos primeiros 30 dias após correção de DSAV total. Todavia, nenhum dos fatores estudados foi determinante para tais graus de IVAVE entre os pacientes com DSAV parcial e transicional.
73

Espectro do transtorno de ansiedade social: estudo de suas comorbidades psiquiátricas e associação com o prolapso de valva mitral / Social anxiety spectrum: study of this psychiatry comorbidities and the association with the mitral valve prolapse

Alaor Santos Filho 16 November 2010 (has links)
Introdução: O transtorno de ansiedade social (TAS) é uma condição que pode ser muito incapacitante, com considerável sofrimento subjetivo, alta prevalência de comorbidades psiquiátricas e impacto negativo no funcionamento psicossocial. Entretanto, existem poucos dados na literatura sobre a possível extensão deste comprometimento nos indivíduos com sinais e sintomas subclínicos do TAS. Além disso, a discussão sobre a associação entre o prolapso de valva mitral (PVM) e os transtornos de ansiedade, particularmente com o transtorno de pânico e o TAS, existe já há cerca de três décadas, mas os resultados publicados não são suficientes para definitivamente estabelecer ou excluir a associação entre essas condições, com prevalências variando de 0 a 57%. Método: O delineamento metodológico envolveu duas etapas. Na primeira, as comorbidades psiquiátricas e o comprometimento no funcionamento psicossocial foram avaliados em 355 estudantes universitários que haviam sido diagnosticados previamente como TAS (n=141), TAS subclínico (n=92) ou controles (n=122). Na segunda etapa, um total de 232 voluntários diagnosticados como transtorno de pânico (n=41), TAS (n=89) ou controles (n=102) foram avaliados em ecocardiografia quanto ao PVM. Os exames foram realizados por dois cardiologistas que estavam cegos em relação ao diagnóstico psiquiátrico dos participantes. Foram obtidas medidas utilizando os critérios atuais e antigos para o diagnóstico de PVM, para permitir a comparação e generalização dos resultados. Resultados: A taxa de comorbidade com outros transtornos psiquiátricos foi de 71,6% no grupo TAS e de 50% nos sujeitos com TAS subclínico, ambos significativamente maiores que os controles (28,7%). A presença de comorbidades foi progressivamente maior de acordo com o subtipo e a gravidade do TAS. Quanto ao funcionamento psicossocial o grupo TAS apresentou maior comprometimento que os outros dois grupos em todos os domínios avaliados, e os sujeitos com TAS subclínico apresentaram valores intermediários. Na segunda etapa, os resultados demonstraram que não há diferenças estatísticas entre os grupos quanto à prevalência de PVM, seja pelos critérios ecocardiográficos atuais para o diagnóstico de PVM (visão longitudinal paraesternal: pânico=2,4%, TAS=4,5%, controles=1,0%) ou pelos critérios antigos (visão apical de 4-câmaras: pânico=2,4%, TAS=4,5%, controles=10,8%; modo-M: pânico=2,4%, TAS=6,7%, controles=4,9%). Também não houve diferenças significativas em relação a outras características morfológicas, como presença de regurgitação mitral, espessamento valvar ou presença de alongamento de cordoalhas. Conclusões: A prevalência de comorbidades psiquiátricas e o comprometimento no funcionamento psicossocial aumentam progressivamente ao longo do espectro de ansiedade social. O fato de o TAS subclínico apresentar considerável incapacidade e sofrimento em comparação com sujeitos controles justifica uma revisão na validade desses critérios diagnósticos. Por outro lado, não houve associação entre o transtorno de pânico ou o TAS com o PVM em nossos resultados, independente dos critérios diagnósticos utilizados, com prevalências compatíveis com a esperada na população geral. Dessa forma, é preciso desmistificar a relação entre essa alteração cardíaca e o transtorno de pânico e o TAS, pelas repercussões que pode ter para o paciente e em seu tratamento psiquiátrico. / Background: Social anxiety disorder (SAD) is a highly disabling condition that causes considerable subjective suffering. It has a high prevalence rate of psychiatric comorbidities and a negative impact on psychosocial functioning. However, few data are available in the literature about the possible extent of this impairment in individuals with subthreshold signs and symptoms of SAD. In addition, the discussion about the association between mitral valve prolapse (MVP) and anxiety disorders, especially panic disorder and SAD, has been going on for over three decades, but the published results are insufficient to establish or to exclude an association between these conditions, with reported prevalence rates ranging from 0% to 57%. Method: The methodological design involved two stages. In the first, psychiatric comorbidities and psychosocial functioning impairment were evaluated in 355 college students diagnosed with SAD (n=141), subthreshold SAD (n=92) or as healthy controls (n=122) in a previous study. In the second stage, a total of 232 volunteers previously diagnosed with panic disorder (n=41), SAD (n=89) or as healthy controls (n=102) underwent echocardiographic evaluation for MVP. The exams were performed by two cardiologists who were blind to the psychiatric diagnosis of the participants. Measurements based on current and earlier MVP diagnostic criteria were taken in order to permit the comparison and generalization of the results. Results: The rate of comorbidity with other psychiatric disorders was 71.6% in the SAD group and 50% in subjects with subthreshold SAD, both significantly greater than controls (28.7%). The presence of comorbidities increased progressively according to SAD subtype and severity. Concerning psychosocial functioning, the SAD group had greater impairment than the other two groups in all domains evaluated, and subjects with subthreshold SAD presented intermediate values. In the second stage, the results demonstrated that there were no statistically significant differences among the groups in terms of MVP prevalence, whether using current diagnostic criteria (long-axis view: panic=2.4%, SAD=4.5%, control=1.0%) or earlier criteria (apical four-chamber view: panic=2.4%, SAD=4.5%, control=10.8%; M-mode: panic=2.4%, SAD=6.7%, control=4.9%). Also, there were no significant differences regarding other morphological characteristics, such as presence of mitral regurgitation, mean valve thickness or elongation of chordae. Conclusions: The rates of psychiatric comorbidities and the psychosocial functioning impairment increase progressively along the spectrum of social anxiety. The fact that subthreshold SAD causes considerable disability and suffering in comparison with control subjects justifies a review of the validity of current diagnostic criteria. On the other hand, in this investigation no association between panic disorder or SAD and MVP was documented, regardless of the diagnostic criteria used, with prevalence rates similar to those reported for the general population. Thus, it seems necessary to demystify the relationship between this cardiac alteration and panic disorder and SAD in order to avoid unwanted influences for the patient and his psychiatric treatment.
74

Prótese valvar mitral : 20 anos de seguimento de uma amostra de pacientes operados no Hospital de Clínicas de Porto Alegre, Rio Grande do Sul, Brasil

Ribeiro, Angela Henrique Silva January 2013 (has links)
Este estudo avalia mortalidade, reoperação e eventos hemorrágicos em pacientes submetidos à cirurgia para troca valvar mitral utilizando substituto biológico ou mecânico. O delineamento do estudo foi do tipo coorte histórica. Entre todos os registros, foram selecionados 352 prontuários de pacientes submetidos à cirurgia para troca valvar mitral entre 1990 e 2008, que tiveram seguimento mínimo de 5 e máximo de 23 anos. Para avaliar o tempo de sobrevida, a probabilidade de reoperação e de eventos hemorrágicos, foi utilizada a curva de Kaplan-Meier. Foi aplicado, para comparar as curvas entre os grupos, o teste qui-quadrado de Log-rank. A análise multivariada de Regressão de Cox foi utilizada para identificar preditores independentes de mortalidade, reoperação e eventos hemorrágicos. A sobrevivência em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 87,7%, 74,2%, 69,3% e 69,3% e, para substituto biológico, foi de 87,6%, 71,0%, 64,2%, e 56,6%, respectivamente. Não houve diferença significativa entre a mortalidade entre os dois grupos (p=0,38). Na análise multivariada, os fatores associados com o óbito foram: idade, eventos hemorrágicos e insuficiência renal. A probabilidade de permanecer livre de reoperação em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 94,4%, 92,7%, 92,7% e 92,7% e, para bioprótese, foi de 95,9%, 86,4%, 81,2% e 76,5%, respectivamente (p=0.073), com uma incidência significativamente maior de reoperação para bioprótese (p=0,008). Os fatores associados com reoperação foram: sexo masculino, diâmetro da prótese e endocardite. A probabilidade de permanecer livre de eventos hemorrágicos em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 95,0%, 91,0%, 89,6% e 89,6% e, para bioprótese, foi de 96,9%, 94,0%, 94,0% e 94,0%, respectivamente (p=0,267). Os fatores associados com eventos hemorrágicos foram: IMC (índice de massa corporal) superior à 30 kg/m2, doença pulmonar obstrutiva crônica, tempo de ventilação mecânica na Unidade de Tratamento Intensivo superior a 30 dias e presença insuficiência mitral. Os autores concluíram que: 1) a mortalidade foi estatisticamente semelhante entre os dois grupos no seguimento; 2) houve tendência maior à reoperação no grupo com bioprótese; 3) após 10 anos de seguimento, a probabilidade de permanecer livre de reoperação não mudou para pacientes com substitutos valvares mecânicos; 4) a probabilidade de permanecer livre de eventos hemorrágicos não mudou após 10 anos de seguimento para portadores de biopróteses; 5) as características basais dos pacientes foram os maiores determinantes de mortalidade tardia após a cirurgia; 6) o tipo de prótese não foi fator preditor independente associado a nenhum dos desfechos avaliados na análise multivariada. / This study assessed mortality, reoperation and bleeding events in patients who underwent mitral valve replacement surgery with a biological or mechanical substitute. This was a historical cohort study. In total, 352 inpatients clinical health records who underwent mitral valve replacement surgery between 1990 and 2008 with 5 to 23 years of follow-up were selected. A Kaplan-Meier curve was used to evaluate the survival time, the probability of reoperation and bleeding events. A log-rank chi-square test was applied to compare the curves between groups. Multivariate Cox regression analysis was used to identify independent predictors of mortality, reoperation and bleeding events. The 5, 10, 15 and 20 year survival rates after surgery using a mechanical substitute were 87.7%, 74.2%, 69.3% and 69.3%, respectively, while the survival rates after surgery with a biological substitute were 87.6%, 71.0%, 64.2% and 56.6%, respectively. There was no significant difference in mortality between the two groups (p = 0.38). In the multivariate analysis, the factors associated with death were age, bleeding events and renal failure. The probabilities of being free of reoperation at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 94.4%, 92.7%, 92.7% and 92.7%, respectively, while after surgery with a bioprosthesis, they were 95.9%, 86.4%, 81.2% and 76.5%, respectively (p = 0.073); therefore, there was a significantly higher incidence of reoperation for patients receiving a bioprosthesis (p = 0.008). The factors associated with reoperation were male gender, diameter of the prosthesis and endocarditis. The probabilities of remaining free of bleeding events at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 95.0%, 91.0%, 89.6% and 89.6, respectively, while after surgery with a bioprosthesis, they were 96.9%, 94.0%, 94.0% and 94.0%, respectively (p = 0.267). The factors associated with bleeding events were BMI (body mass index) greater than 30 kg/m2, chronic obstructive pulmonary disease, mechanical ventilation at an Intensive Care Unit for longer than 30 days and mitral regurgitation. The authors concluded that: 1) mortality during follow-up was statistically similar in both groups; 2) there was a greater tendency to reoperation in the bioprosthesis group; 3) the probability of survival free from reoperation did not change for patients with mechanical valves after 10 years’ follow-up; 4) the probability of survival free from bleeding events did not change after 10 years’ follow-up for bioprostheses patients; 5) patients’ baseline characteristics were the greatest determinants of late mortality after mitral valve replacement surgery; 6) the type of prosthesis fitted was not an independent predictive factor of any of the outcomes analyzed in the multivariate analysis.
75

Estudo dos efeitos da hipertensão arterial nas alterações morfológicas da valva atrioventricular esquerda (mitral) de ratos hipertensos induzidas por L-NAME / Studies of the effects of arterial hypertension on the morphological changes of the left atrioventricular valve(mitral) of hypertensive rats induced by L-NAME

Vinícius Novaes Rocha 18 February 2009 (has links)
As valvas cardíacas têm como função manter o fluxo unidirecional do sangue e para isso conta com uma arquitetura anisotrópica da matriz extracelular que assegura e sustenta uma adequada função sob condições de alta e baixa pressão. A valvopatia é uma desordem que pode acometer qualquer uma das valvas cardíacas por qualquer modificação em sua estrutura que impossibilita o seu adequado funcionamento. Estudos demonstram que o stress mecânico ocasionado pelo fluxo sanguíneo pode interferir na estrutura organizacional das células e matriz extracelular da valva. O presente estudo teve como objetivo investigar as possíveis alterações estruturais e ultraestruturais que a hipertensão arterial, induzida por L-NAME, pode ocasionar na valva atrioventricular esquerda (mitral) de corações de ratos. Os animais receberam L-NAME (40mg/kg/dia), previamente diluído na água de beber, durante um período de cinco semanas. Ao final da quinta semana foi realizada a eutanásia dos animais e fragmentos da válvula parietal foram coletados e processados para microscopia de luz e eletrônica. Foram analisadas as estruturas morfológicas das válvulas tanto para microscopia óptica (histoquímica) quanto microscopia eletrônica (histoquímica ultraestrutural e imunohistoquímica ultraestrutural), assim como, a espessura da válvula e a quantificação (%/area) das fibras elásticas e colágenas através do programa ImagePro-Plus 4.5. Os animais tratados com L-NAME desenvolveram hipertensão a partir da segunda semana de administração do fármaco. Estruturalmente foi possível identificar uma desorganização das fibras elásticas e colágenas com regiões de fragmentação. Os animais hipertensos apresentaram regiões da válvula mais espessas do que o controle, além de uma menor porcentagem de fibras colágenas. Ultraestruturalmente, identificamos modificações do endotélio nos animais tratados com L-NAME, que se apresentou com contorno irregular e com acúmulos de vesículas no seu interior. Além disso, foi observada também fragmentação da lâmina basal, desorientação das fibras colágenas, acúmulo de fibras oxitalânicas próximo ao endotélio e fragmentação das fibras elástica da região atrial. O presente trabalho concluiu que o aumento da pressão sanguínea, caracterizada pela hipertensão, ocasiona modificações na estrutura morfológica da válvula, que pode estar associado de forma sinérgica com a inibição da síntese óxido do nítrico, podendo assim, prejudicar o seu perfeito funcionamento. / The heart valves are designed to maintain the unidirectional blood flow and for this reason they have an anisotropic architecture of the extracellular matrix that ensures and maintains proper function under conditions of high and low pressure. The valve disease is a disorder that can affect any of the heart valves, marked by any change in its structure that prevents its proper operation. Studies show that the mechanical stress caused by blood flow may interfere with the organizational structure of cells and extracellular matrix of the valve. This study aimed to investigate the possible structural and ultrastructural changes that hypertension, induced by L-NAME, can cause to the left atrioventricular valve (mitral) from hearts of rats. The animals received L-NAME (40mg/kg/dia), previously diluted in water, for five weeks. At the end of the fifth week euthanasia of animals was performed and the valve parietal fragments were collected and processed for light microscopy (histochemistry) and electron microscopy (ultrastructural histochemistry and ultrastructural immunohistochemistry). It was analyzed the morphological structure of the valves at both structural (light microscopy) and ultrastructural (electron microscopy), as well as the thickness of the valve and quantification (% / area) of the elastic and collagen fibers through the ImagePro-Plus 4.5. The animals treated with L-NAME developed hypertension from the second week of administration of the drug. Structurally, it was possible to identify a disorganization of the elastic and collagen fibers with regions of fragmentation. The hypertension animals showed thicker valve regions than control, plus a smaller amount of collagen fibers. Ultrastructurally, it was identified changes of the endothelium in animals treated with L-NAME, where it presented irregular contours and accumulations of vesicles inside. Furthermore, it was also observed fragmentation of basal lamina, disorientation of collagen fibers, fiber oxytalan accumulation near the endothelium and fragmentation of elastic fibers of the atrial layer. This study concluded that increased blood pressure, characterized by hypertension, causes changes in the morphological structure of the valve, which may be linked in with the synergistic inhibition of nitric oxide synthesis, and may thus undermine its perfect operation.
76

Estudo dos efeitos da hipertensão arterial nas alterações morfológicas da valva atrioventricular esquerda (mitral) de ratos hipertensos induzidas por L-NAME / Studies of the effects of arterial hypertension on the morphological changes of the left atrioventricular valve(mitral) of hypertensive rats induced by L-NAME

Vinícius Novaes Rocha 18 February 2009 (has links)
As valvas cardíacas têm como função manter o fluxo unidirecional do sangue e para isso conta com uma arquitetura anisotrópica da matriz extracelular que assegura e sustenta uma adequada função sob condições de alta e baixa pressão. A valvopatia é uma desordem que pode acometer qualquer uma das valvas cardíacas por qualquer modificação em sua estrutura que impossibilita o seu adequado funcionamento. Estudos demonstram que o stress mecânico ocasionado pelo fluxo sanguíneo pode interferir na estrutura organizacional das células e matriz extracelular da valva. O presente estudo teve como objetivo investigar as possíveis alterações estruturais e ultraestruturais que a hipertensão arterial, induzida por L-NAME, pode ocasionar na valva atrioventricular esquerda (mitral) de corações de ratos. Os animais receberam L-NAME (40mg/kg/dia), previamente diluído na água de beber, durante um período de cinco semanas. Ao final da quinta semana foi realizada a eutanásia dos animais e fragmentos da válvula parietal foram coletados e processados para microscopia de luz e eletrônica. Foram analisadas as estruturas morfológicas das válvulas tanto para microscopia óptica (histoquímica) quanto microscopia eletrônica (histoquímica ultraestrutural e imunohistoquímica ultraestrutural), assim como, a espessura da válvula e a quantificação (%/area) das fibras elásticas e colágenas através do programa ImagePro-Plus 4.5. Os animais tratados com L-NAME desenvolveram hipertensão a partir da segunda semana de administração do fármaco. Estruturalmente foi possível identificar uma desorganização das fibras elásticas e colágenas com regiões de fragmentação. Os animais hipertensos apresentaram regiões da válvula mais espessas do que o controle, além de uma menor porcentagem de fibras colágenas. Ultraestruturalmente, identificamos modificações do endotélio nos animais tratados com L-NAME, que se apresentou com contorno irregular e com acúmulos de vesículas no seu interior. Além disso, foi observada também fragmentação da lâmina basal, desorientação das fibras colágenas, acúmulo de fibras oxitalânicas próximo ao endotélio e fragmentação das fibras elástica da região atrial. O presente trabalho concluiu que o aumento da pressão sanguínea, caracterizada pela hipertensão, ocasiona modificações na estrutura morfológica da válvula, que pode estar associado de forma sinérgica com a inibição da síntese óxido do nítrico, podendo assim, prejudicar o seu perfeito funcionamento. / The heart valves are designed to maintain the unidirectional blood flow and for this reason they have an anisotropic architecture of the extracellular matrix that ensures and maintains proper function under conditions of high and low pressure. The valve disease is a disorder that can affect any of the heart valves, marked by any change in its structure that prevents its proper operation. Studies show that the mechanical stress caused by blood flow may interfere with the organizational structure of cells and extracellular matrix of the valve. This study aimed to investigate the possible structural and ultrastructural changes that hypertension, induced by L-NAME, can cause to the left atrioventricular valve (mitral) from hearts of rats. The animals received L-NAME (40mg/kg/dia), previously diluted in water, for five weeks. At the end of the fifth week euthanasia of animals was performed and the valve parietal fragments were collected and processed for light microscopy (histochemistry) and electron microscopy (ultrastructural histochemistry and ultrastructural immunohistochemistry). It was analyzed the morphological structure of the valves at both structural (light microscopy) and ultrastructural (electron microscopy), as well as the thickness of the valve and quantification (% / area) of the elastic and collagen fibers through the ImagePro-Plus 4.5. The animals treated with L-NAME developed hypertension from the second week of administration of the drug. Structurally, it was possible to identify a disorganization of the elastic and collagen fibers with regions of fragmentation. The hypertension animals showed thicker valve regions than control, plus a smaller amount of collagen fibers. Ultrastructurally, it was identified changes of the endothelium in animals treated with L-NAME, where it presented irregular contours and accumulations of vesicles inside. Furthermore, it was also observed fragmentation of basal lamina, disorientation of collagen fibers, fiber oxytalan accumulation near the endothelium and fragmentation of elastic fibers of the atrial layer. This study concluded that increased blood pressure, characterized by hypertension, causes changes in the morphological structure of the valve, which may be linked in with the synergistic inhibition of nitric oxide synthesis, and may thus undermine its perfect operation.
77

Prótese valvar mitral : 20 anos de seguimento de uma amostra de pacientes operados no Hospital de Clínicas de Porto Alegre, Rio Grande do Sul, Brasil

Ribeiro, Angela Henrique Silva January 2013 (has links)
Este estudo avalia mortalidade, reoperação e eventos hemorrágicos em pacientes submetidos à cirurgia para troca valvar mitral utilizando substituto biológico ou mecânico. O delineamento do estudo foi do tipo coorte histórica. Entre todos os registros, foram selecionados 352 prontuários de pacientes submetidos à cirurgia para troca valvar mitral entre 1990 e 2008, que tiveram seguimento mínimo de 5 e máximo de 23 anos. Para avaliar o tempo de sobrevida, a probabilidade de reoperação e de eventos hemorrágicos, foi utilizada a curva de Kaplan-Meier. Foi aplicado, para comparar as curvas entre os grupos, o teste qui-quadrado de Log-rank. A análise multivariada de Regressão de Cox foi utilizada para identificar preditores independentes de mortalidade, reoperação e eventos hemorrágicos. A sobrevivência em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 87,7%, 74,2%, 69,3% e 69,3% e, para substituto biológico, foi de 87,6%, 71,0%, 64,2%, e 56,6%, respectivamente. Não houve diferença significativa entre a mortalidade entre os dois grupos (p=0,38). Na análise multivariada, os fatores associados com o óbito foram: idade, eventos hemorrágicos e insuficiência renal. A probabilidade de permanecer livre de reoperação em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 94,4%, 92,7%, 92,7% e 92,7% e, para bioprótese, foi de 95,9%, 86,4%, 81,2% e 76,5%, respectivamente (p=0.073), com uma incidência significativamente maior de reoperação para bioprótese (p=0,008). Os fatores associados com reoperação foram: sexo masculino, diâmetro da prótese e endocardite. A probabilidade de permanecer livre de eventos hemorrágicos em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 95,0%, 91,0%, 89,6% e 89,6% e, para bioprótese, foi de 96,9%, 94,0%, 94,0% e 94,0%, respectivamente (p=0,267). Os fatores associados com eventos hemorrágicos foram: IMC (índice de massa corporal) superior à 30 kg/m2, doença pulmonar obstrutiva crônica, tempo de ventilação mecânica na Unidade de Tratamento Intensivo superior a 30 dias e presença insuficiência mitral. Os autores concluíram que: 1) a mortalidade foi estatisticamente semelhante entre os dois grupos no seguimento; 2) houve tendência maior à reoperação no grupo com bioprótese; 3) após 10 anos de seguimento, a probabilidade de permanecer livre de reoperação não mudou para pacientes com substitutos valvares mecânicos; 4) a probabilidade de permanecer livre de eventos hemorrágicos não mudou após 10 anos de seguimento para portadores de biopróteses; 5) as características basais dos pacientes foram os maiores determinantes de mortalidade tardia após a cirurgia; 6) o tipo de prótese não foi fator preditor independente associado a nenhum dos desfechos avaliados na análise multivariada. / This study assessed mortality, reoperation and bleeding events in patients who underwent mitral valve replacement surgery with a biological or mechanical substitute. This was a historical cohort study. In total, 352 inpatients clinical health records who underwent mitral valve replacement surgery between 1990 and 2008 with 5 to 23 years of follow-up were selected. A Kaplan-Meier curve was used to evaluate the survival time, the probability of reoperation and bleeding events. A log-rank chi-square test was applied to compare the curves between groups. Multivariate Cox regression analysis was used to identify independent predictors of mortality, reoperation and bleeding events. The 5, 10, 15 and 20 year survival rates after surgery using a mechanical substitute were 87.7%, 74.2%, 69.3% and 69.3%, respectively, while the survival rates after surgery with a biological substitute were 87.6%, 71.0%, 64.2% and 56.6%, respectively. There was no significant difference in mortality between the two groups (p = 0.38). In the multivariate analysis, the factors associated with death were age, bleeding events and renal failure. The probabilities of being free of reoperation at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 94.4%, 92.7%, 92.7% and 92.7%, respectively, while after surgery with a bioprosthesis, they were 95.9%, 86.4%, 81.2% and 76.5%, respectively (p = 0.073); therefore, there was a significantly higher incidence of reoperation for patients receiving a bioprosthesis (p = 0.008). The factors associated with reoperation were male gender, diameter of the prosthesis and endocarditis. The probabilities of remaining free of bleeding events at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 95.0%, 91.0%, 89.6% and 89.6, respectively, while after surgery with a bioprosthesis, they were 96.9%, 94.0%, 94.0% and 94.0%, respectively (p = 0.267). The factors associated with bleeding events were BMI (body mass index) greater than 30 kg/m2, chronic obstructive pulmonary disease, mechanical ventilation at an Intensive Care Unit for longer than 30 days and mitral regurgitation. The authors concluded that: 1) mortality during follow-up was statistically similar in both groups; 2) there was a greater tendency to reoperation in the bioprosthesis group; 3) the probability of survival free from reoperation did not change for patients with mechanical valves after 10 years’ follow-up; 4) the probability of survival free from bleeding events did not change after 10 years’ follow-up for bioprostheses patients; 5) patients’ baseline characteristics were the greatest determinants of late mortality after mitral valve replacement surgery; 6) the type of prosthesis fitted was not an independent predictive factor of any of the outcomes analyzed in the multivariate analysis.
78

Prótese valvar mitral : 20 anos de seguimento de uma amostra de pacientes operados no Hospital de Clínicas de Porto Alegre, Rio Grande do Sul, Brasil

Ribeiro, Angela Henrique Silva January 2013 (has links)
Este estudo avalia mortalidade, reoperação e eventos hemorrágicos em pacientes submetidos à cirurgia para troca valvar mitral utilizando substituto biológico ou mecânico. O delineamento do estudo foi do tipo coorte histórica. Entre todos os registros, foram selecionados 352 prontuários de pacientes submetidos à cirurgia para troca valvar mitral entre 1990 e 2008, que tiveram seguimento mínimo de 5 e máximo de 23 anos. Para avaliar o tempo de sobrevida, a probabilidade de reoperação e de eventos hemorrágicos, foi utilizada a curva de Kaplan-Meier. Foi aplicado, para comparar as curvas entre os grupos, o teste qui-quadrado de Log-rank. A análise multivariada de Regressão de Cox foi utilizada para identificar preditores independentes de mortalidade, reoperação e eventos hemorrágicos. A sobrevivência em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 87,7%, 74,2%, 69,3% e 69,3% e, para substituto biológico, foi de 87,6%, 71,0%, 64,2%, e 56,6%, respectivamente. Não houve diferença significativa entre a mortalidade entre os dois grupos (p=0,38). Na análise multivariada, os fatores associados com o óbito foram: idade, eventos hemorrágicos e insuficiência renal. A probabilidade de permanecer livre de reoperação em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 94,4%, 92,7%, 92,7% e 92,7% e, para bioprótese, foi de 95,9%, 86,4%, 81,2% e 76,5%, respectivamente (p=0.073), com uma incidência significativamente maior de reoperação para bioprótese (p=0,008). Os fatores associados com reoperação foram: sexo masculino, diâmetro da prótese e endocardite. A probabilidade de permanecer livre de eventos hemorrágicos em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 95,0%, 91,0%, 89,6% e 89,6% e, para bioprótese, foi de 96,9%, 94,0%, 94,0% e 94,0%, respectivamente (p=0,267). Os fatores associados com eventos hemorrágicos foram: IMC (índice de massa corporal) superior à 30 kg/m2, doença pulmonar obstrutiva crônica, tempo de ventilação mecânica na Unidade de Tratamento Intensivo superior a 30 dias e presença insuficiência mitral. Os autores concluíram que: 1) a mortalidade foi estatisticamente semelhante entre os dois grupos no seguimento; 2) houve tendência maior à reoperação no grupo com bioprótese; 3) após 10 anos de seguimento, a probabilidade de permanecer livre de reoperação não mudou para pacientes com substitutos valvares mecânicos; 4) a probabilidade de permanecer livre de eventos hemorrágicos não mudou após 10 anos de seguimento para portadores de biopróteses; 5) as características basais dos pacientes foram os maiores determinantes de mortalidade tardia após a cirurgia; 6) o tipo de prótese não foi fator preditor independente associado a nenhum dos desfechos avaliados na análise multivariada. / This study assessed mortality, reoperation and bleeding events in patients who underwent mitral valve replacement surgery with a biological or mechanical substitute. This was a historical cohort study. In total, 352 inpatients clinical health records who underwent mitral valve replacement surgery between 1990 and 2008 with 5 to 23 years of follow-up were selected. A Kaplan-Meier curve was used to evaluate the survival time, the probability of reoperation and bleeding events. A log-rank chi-square test was applied to compare the curves between groups. Multivariate Cox regression analysis was used to identify independent predictors of mortality, reoperation and bleeding events. The 5, 10, 15 and 20 year survival rates after surgery using a mechanical substitute were 87.7%, 74.2%, 69.3% and 69.3%, respectively, while the survival rates after surgery with a biological substitute were 87.6%, 71.0%, 64.2% and 56.6%, respectively. There was no significant difference in mortality between the two groups (p = 0.38). In the multivariate analysis, the factors associated with death were age, bleeding events and renal failure. The probabilities of being free of reoperation at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 94.4%, 92.7%, 92.7% and 92.7%, respectively, while after surgery with a bioprosthesis, they were 95.9%, 86.4%, 81.2% and 76.5%, respectively (p = 0.073); therefore, there was a significantly higher incidence of reoperation for patients receiving a bioprosthesis (p = 0.008). The factors associated with reoperation were male gender, diameter of the prosthesis and endocarditis. The probabilities of remaining free of bleeding events at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 95.0%, 91.0%, 89.6% and 89.6, respectively, while after surgery with a bioprosthesis, they were 96.9%, 94.0%, 94.0% and 94.0%, respectively (p = 0.267). The factors associated with bleeding events were BMI (body mass index) greater than 30 kg/m2, chronic obstructive pulmonary disease, mechanical ventilation at an Intensive Care Unit for longer than 30 days and mitral regurgitation. The authors concluded that: 1) mortality during follow-up was statistically similar in both groups; 2) there was a greater tendency to reoperation in the bioprosthesis group; 3) the probability of survival free from reoperation did not change for patients with mechanical valves after 10 years’ follow-up; 4) the probability of survival free from bleeding events did not change after 10 years’ follow-up for bioprostheses patients; 5) patients’ baseline characteristics were the greatest determinants of late mortality after mitral valve replacement surgery; 6) the type of prosthesis fitted was not an independent predictive factor of any of the outcomes analyzed in the multivariate analysis.
79

Determinação da proporção entre os segmentos do anel da valva tricuspide : estudo anatomico em corações de humanos / Proportion between the segments of the tricuspid valve annulus : anatomic study with human hearts

Antoniali, Fernando 26 July 2006 (has links)
Orientador: Domingo Marcolino Braile / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-07T03:55:43Z (GMT). No. of bitstreams: 1 Antoniali_Fernando_M.pdf: 4775200 bytes, checksum: 8361f227d501574e0c98c3965065c58b (MD5) Previous issue date: 2006 / Resumo: Objetivo: Determinar a proporção existente entre os segmentos do anel da valva tricúspide normal em humanos. Método: Foram estudados 30 corações de cadáveres humanos não formolizados, com menos de 6h de período ¿post-mortem¿, sem lesões congênitas ou adquiridas e com valvas tricúspides sem deformidades e continentes. A continência desta valva foi confirmada por injeção de água sob pressão no interior do ventrículo direito estando a valva pulmonar fechada. Foram realizadas fotos digitais da valva tricúspide com o anel valvar íntegro e após secção na comissura póstero-septal e retificação do anel valvar. Estas fotos contendo escalas milimetradas foram avaliadas por programa específico de computador. Foram feitas medidas computadorizadas do perímetro, segmento septal e segmento ântero-posterior do anel valvar íntegro. Nesta condição também foram feitas medidas da distância linear entre as comissuras ântero-septal e póstero-septal. Na condição de anel valvar retificado, foram realizadas medidas computadorizadas e manuais do perímetro e dos segmentos septal, anterior e posterior do anel valvar tricuspídeo. Compararam-se as medidas médias e as razões entre elas nas condições de anel íntegro e retificado. Compararam-se, também, a forma computadorizada e manual de mensuração do anel. Resultados: Nas medidas computadorizadas realizadas com imagens digitais do anel valvar íntegro, os valores médios do perímetro, segmento septal e ântero-posterior foram 105mm (±12,7), 30,6mm (±3,7) e 74mm (±9,4), respectivamente. A distância linear média entre as comissuras ântero-septal e póstero-septal foi de 28,9mm (±3,4). Nas medidas computadorizadas realizadas com imagens digitais do anel valvar retificado, os valores médios foram 117,5mm (±13,3), 32mm (±3,7), 46,3mm (±8,3) e 39,1mm (±8,5), respectivamente para perímetro, segmento septal, anterior e posterior. A razão média entre o segmento ântero-posterior e o septal foi 2,43 (±0,212) e 2,67 (±0,304) respectivamente em anéis íntegros e retificados. Houve diferenças significantes entre as medidas do perímetro (p<0,0001), do segmento septal (p=0,003) e do segmento ântero-posterior (p<0,0001) quando realizadas em anéis íntegros e retificados. As razões entre segmento ântero-posterior e septal também apresentaram diferença significante (p=0,0005). As medidas manuais do anel valvar retificado apresentaram os valores médios de 118,5mm (±12,7), 32,6mm (±3,4), 46,6mm (±7,7) e 39,3mm (±7,9), respectivamente para perímetro, segmento septal, anterior e posterior. Não houve diferenças significantes entre medidas manuais e computadorizadas. Conclusões: A proporção existente entre os segmento septal e o segmento ântero-posterior, do anel da valva tricúspide normal em humanos, é igual a 1 : 2,43. A secção e retificação do anel tricuspídeo altera as medidas de seus segmentos e suas relações / Abstract: Objective: The purpose of this study was to determine the proportion among the segments of the human tricuspid valve annulus. Methods: Descriptive autopsy study of 30 human hearts, without fixation, with less than six hours of post-mortem period, without congenital or acquired lesions and without tricuspid regurgitation. The tricuspid valve insufficiency was excluded by infusion of pressured water in the right ventricle with closed pulmonary valve. Digital images of the tricuspid ring on anatomical position and on flattened state were analyzed by specific software. Computerized measurements of the perimeter, septal segment, anteroposterior segment and the linear distance between the anteroseptal and posteroseptal commissures were obtained on anatomical position. Computerized and manual measurements of the perimeter, septal, anterior and posterior segments were obtained on flattened state. The measurements were demonstrated and compared on the two different situations, anatomical position and flattened. The computerized measurements were compared with the manual ones. Results: The mean values of the perimeter, septal and anteroposterior segments of the tricuspid ring, obtained by computerized measurements on anatomical position were: 105mm (±12.7), 30.6mm (±3.7) e 74mm (±9.4), respectively. The mean linear distance between the anteroseptal and posteroseptal commissures was 28.9mm (±3.4). On the flattened state and by computerized measurements, the mean value of the perimeter was 117.5mm (±13.3) and of the septal, anterior e posterior segments were respectively: 32mm (±3.7), 46.3mm (±8.3) e 39.1mm (±8.5). The mean ratio between the antero-posterior and septal segments was 2.43 (±0.212) on the anatomical position and on flattened state was 2.67 (±0.304). Statistical differences were observed in the measurements of perimeter (p<0.0001), septal segment (p=0.003) e antero-posterior segment (p<0.0001) on the two situations. Statistical difference also occurred on the ratios between the antero-posterior and septal segments (p=0.0005). The mean values obtained by manual measurements of the tricuspid ring on flattened state were: 118.5mm (±12.7), 32.6mm (±3.4), 46.6mm (±7.7) e 39.3mm (±7.9), respectively for perimeter, septal, anterior and posterior segments. There weren¿t statistical differences on computerized and manual measurements. Conclusions: The proportion between the septal and antero-posterior segments of the normal human tricuspid valve is 1 : 2.43. The attitude of flatting the tricuspid ring to measure the segments, changes their values and the ratios between them / Mestrado / Cirurgia / Mestre em Cirurgia
80

Correlação entre topografia da calcificação valvar e repercussão hemodinâmica na estenose aórtica degenerativa / Correlation between topographic distribution of aortic valve calcium and hemodynamic repercussion in degenerative aortic stenosis

Antonio Sergio de Santis Andrade Lopes 17 April 2018 (has links)
Introdução: A deposição de cálcio junto aos folhetos valvares esta intimamente relacionada à fisiopatologia da estenose valvar aórtica degenerativa (EAD). A tomografia computadorizada com multidetectores (TCMD), além de possibilitar o delineamento tridimensional das estruturas cardíacas, permite a quantificação da intensidade da calcificação valvar. Atualmente, a relação entre a localização dos depósitos valvares de cálcio e a gravidade hemodinâmica na estenose aórtica permanece incerta. Objetivo: Avaliar se a topografia da calcificação valvar influencia a repercussão hemodinâmica na EAD. Métodos: Trata-se de estudo prospectivo, unicêntrico, incluindo 97 pacientes com EAD moderada ou importante. O escore de cálcio da valva aórtica foi calculado a partir da TCMD sem contraste. A topografia da calcificação valvar foi avaliada através de análise tomográfica específica com infusão de baixa dose de contraste endovenoso, objetivando uma detalhada segmentação anatômica dos planos valvares. A medida da atenuação, expressa em unidades Hounsfield (UH), foi utilizada para quantificar o conteúdo de cálcio na região central e periférica do plano valvar aórtico. Resultados: Pacientes com EAD importante apresentaram escore de cálcio valvar aórtico superior ao dos portadores de EAD moderada (3131 ± 1828 unidades Agatston [UA] e 1302 ± 846 UA, respectivamente; p < 0,001). Quanto à topografia da calcificação, pacientes com EAD importante exibiram atenuações significativamente maiores no centro do plano valvar do que em sua periferia (507,4 ± 181,7 UH vs. 449,8 ± 114,5 UH; p = 0,001). Inversamente, pacientes com EAD moderada apresentaram menor atenuação na região central do que na periferia valvar (308,7 ± 92,9 UH vs. 347,6 ± 84,2 UH, p < 0,001). A razão da atenuação centro/periferia também foi significativamente maior nos pacientes com EAD importante (1,14 ± 0,32 vs. 0,89 ± 0,13; p < 0,001), permanecendo significativamente associada à presença de EAD importante mesmo após ajuste para o grau subjacente de calcificação Resumo valvar. Conclusão: A gravidade da EAD parece resultar não apenas do grau de calcificação, mas também da localização dos depósitos valvares de cálcio / Introduction: The pathophysiology of degenerative aortic valve stenosis (AS) is intimately related to the development of calcific deposits in the valve structure. Multidetector computed tomography (MDCT), a reliable method to delineate the tridimensional heart geometry, has been shown to accurately quantify the global aortic valve calcium content. Currently, the relationship between calcium location and hemodynamic disease severity is poorly understood. Objective: The present prospective study was conducted to test the hypothesis of whether the location of valve calcification influences the functional severity of AS. Methods: Prospective, single-arm study including 97 patients with diagnosed moderate or severe AS. Aortic valve calcium score was calculated from nocontrast multidetector computed tomography (MDCT). \"Low-contrast- os \" MDCT images were acquired for segmentation of the cardiac anatomy, with the attenuation, expressed in Hounsfield units (HU), used to quantify the calcium content at the central and peripheral regions of the aortic valve zone. Results: The calcium score was higher among patients with severe AS compared to patients without severe AS (3131±1828 Agatston units [AU] vs. 1302±846 AU respectively; p < 0.001). Patients with severe AS had significantly higher attenuations at the center of the valve than at its periphery (507.4±181.7 HU vs. 449.8±114.5 HU; p=0.001). Conversely, patients without severe AS had lower attenuation at the center than at the periphery of the valve (308.7 ± 92.9 HU vs. 347.6±84.2 HU; p < 0.001). The center/periphery attenuation ratio was significantly higher for patients with severe AS than for those without severe disease (1.14±0.32 vs. 0.89 ± 0.13; p < 0.001), and remained significantly associated with the presence of severe AS even after adjusting for the underlying degree of valve calcification. Conclusion: The severity of degenerative aortic valve stenosis appears to result not only from the degree of calcification but also from the localization of the calcific deposits within the valve

Page generated in 0.106 seconds