• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 194
  • Tagged with
  • 194
  • 194
  • 142
  • 98
  • 59
  • 49
  • 47
  • 46
  • 35
  • 32
  • 29
  • 26
  • 24
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Cinética do consumo de oxigênio no domínio severo: comparação entre homens e mulheres saudáveis e sedentários.

Azevedo, Paulo Henrique Silva Marques de 16 March 2007 (has links)
Made available in DSpace on 2016-06-02T19:22:47Z (GMT). No. of bitstreams: 1 DissPHSMA.pdf: 1029230 bytes, checksum: 1bf26ddbd8cdbd2c465cd8442edf58ac (MD5) Previous issue date: 2007-03-16 / Universidade Federal de Sao Carlos / The objective of the present study was to analyse and compare the kinetics of oxygen consumption between groups during running in severe domain. Eighteen healthy and sedentary participants were separated by sex, nine men and women (25,20 ± 2,60 years; 22,10 ± 1,80 years and, 77,30 ± 12,30 kg; 58,60 ± 9,60 kg, respectively). An incremental test was realized at treadmill to determine the associated speed to VO2max (vVO2max) and running to exhaustion (Tlim) at vVO2max to determine the VO2 kinetics, with data expressed by average and standard desviation. The VO2max (3,29 ± 0,62 vs 1,90 ± 0,39 L/min) (p&#8804;0,0001); vVO2max (14 ± 2 vs 10 (3) km.h-1) (p<0,0108); amplitude (3 ± 0,70 vs 1,80 ± 0,40 L/min) (p<0,0003) was significantly increased to men. There was not detected a statistic difference between men and women to the constant time [35,80 (22,30) s vs 36,50 (6,60) s] (p<0,2973); Tlim [271 (118) s vs 261 (73) s] (p<0,6849); Target time to achieve VO2max [142,30 (84,50) s vs 175,80 (24,60) s] (p<0,2973); %Tlim to TAVO2max [43,70 (24,40) vs 72,50 (17,70)] (p<0,1903); time maintained at VO2max (TMVO2max) [145,10 (72,50) s vs 64,20 (65,30) s] (p<0,1359), expressed values by median and interquartil amplitude. We conclude that the VO2 kinetics is similar between young and sedentary men and women, despite the biggest VO2 value demonstrated by men. The prescription value to the aerobic intervalled training do not have make off the proposed by literature for medium and high performance athletes. / O presente estudo teve como objetivo analisar e comparar a cinética de consumo de oxigênio entre gêneros em corrida no domínio severo. Participaram do estudo nove homens e nove mulheres (25,2 ± 2,6 anos; 22,1 ± 1,8 anos e, 77,3 ± 12,3 kg; 58,6 ± 9,6 kg, respectivamente). Foi realizado teste incremental em esteira rolante para determinação da velocidade associada ao VO2max (vVO2max), e corrida até a exaustão (Tlim) na vVO2max para determinar a cinética do VO2. O VO2max (3,29 ± 0,62 vs 1,90 ± 0,39) (p&#8804;0,0001), vVO2max (14,0 ± 2,0 vs 10,0 (3,0) km.h-1) (p<0,0108) e a amplitude (3,0 ± 0,7 vs 1,8 ± 0,4 L/min) (p<0,0003) (M±DP) foram significativamente maiores para os homens. Não foi detectada diferença estatística entre homens e mulheres para a constante tempo (&#964;) [35,8 (22,3) s vs 36,5 (6,6) s] (p<0,2973), Tlim [271,0 (118,0) vs 261,0 (73,0)] (p<0,6849), tempo para atingir o VO2max (TAVO2max) [142,3 (84,5) s vs 175,8 (24,6) s] (p<0,2973), %Tlim para TAVO2max [43,7 (24,4) vs 72,5 (17,7)] (p<0,1903); tempo mantido no VO2max (TMVO2max) [145,1 (72,5) s vs 64,2 (65,3) s] (p<0,1359), valores expressos pela mediana e amplitude interquartil. Concluímos que a resposta da cinética do VO2 é semelhante entre homens e mulheres jovens sedentários, apesar do maior valor de VO2max apresentado pelos homens. Palavras chave: Cinética VO2; Gênero; Domínio Severo
112

Decomposição de Staurastrum iversenii Neygaard var. americanum: efeitos da qualidade do recurso, da disponibilidade de oxigênio e da temperatura.

Pacobahyba, Lucilia Dias 23 May 2002 (has links)
Made available in DSpace on 2016-06-02T19:28:51Z (GMT). No. of bitstreams: 1 Pacobahyba.pdf: 806828 bytes, checksum: 80f8829debedd2c2f3a1bbde1053164f (MD5) Previous issue date: 2002-05-23 / Financiadora de Estudos e Projetos / In this work the decomposition aspects of the Staurastrum iversenii Nygaard var. americanum phytoplankton species, isolated from the Barra Bonita Reservoir (22 degrees 29 minutes S e 48 degrees 34 minutes W), were approached; as resource of the decomposition were used: cells (ruptured and whole) and polysaccharide of higher and lower molecular masses. Were approached, still, the effects of the following variables: temperature and concentration of dissolved oxygen. Therefore, decomposition chambers were set up in laboratory with cells (ruptured and whole) and polysaccharides of higher and lower molecular masses deriving from S. iversenii. Based on the quantifications of the organic carbon concentrations, the decomposition processes of the resources were described and the kinetic coefficients evaluated. These descriptions constituted the base of the models proposed for the resource decomposition. These models allowed to infer that the used substrata constituted from a structural point of view, of composed heterogeneous, presenting labile and refracting fractions. In relation to the consumption of oxygen, the decomposition of the ruptured cells was observed to be faster than that of the whole cells; for the polysaccharides, the consumptions of oxygen were faster in the mineralization of the fractions of high molecular mass. The temperature influenced the speeds of the processes involved with the mineralization of the refracting fractions, besides altering the mineralization routes of the resources; it, also, induced the occurrence of alterations of the stoichiometric (O/C) relationships of the processes. It was possible to verify that the sugars which form these polysaccharides contributed with the supply of energy to the microorganisms during a long period. The proposed mathematical models were shown to be sensitive to the experimental results. The degradation of S. iversenii can contribute to the maintenance of the processes connected to the maintenance of the Barra Bonita Reservoir microbial loop. / Neste trabalho foram abordados aspectos da decomposição da espécie fitoplanctônica Staurastrumive iversenii Nygaard var. americanum, isolada do reservatório de Barra Bonita (22 graus 29 minutos S e 48 graus 34 minutos W); como recurso da decomposição utilizaram-se: células (rompidas e íntegras) e polissacarídeos de alta e baixa massas moleculares. Foram abordados, ainda, os efeitos das seguintes variáveis: temperatura e concentração oxigênio dissolvido. Para tanto, montou-se em laboratório, câmaras de decomposição com células (rompidas e íntegras) e polissacarídeos (de alta e baixa massas moleculares) provenientes de S. iversenii. Com base nas quantificações das concentrações de carbono orgânico descreveu-se os processos de decomposição dos recursos e avaliou-se os coeficientes cinéticos. Estas descrições constituíram a base dos modelos propostos para a decomposição dos recursos. Esses modelos permitiram inferir que os substratos utilizados constituíram-se, do ponto de vista estrutural, de compostos heterogêneos, apresentando frações lábeis e refratárias. Em relação ao consumo de oxigênio, observou-se que foi mais rápido na decomposição das células rompidas que das células íntegras; para os polissacarídeos, os consumos de oxigênio foram mais rápidos nas mineralizações das frações de alta massa molecular. A temperatura influenciou as velocidades dos processos envolvidos com a mineralização das frações refratárias, além de alterar as rotas das mineralizações dos recursos; induziu, também, a ocorrência de alterações das relações estequiométricas (O/C) dos processos. Foi possível verificar que os açucares que formam estes polissacarídeos contribuíram com o fornecimento de energia para os microrganismos durante um longo período. Os modelos matemáticos propostos mostraram-se sensíveis aos resultados experimentais. A degradação de S. iversenii pode contribuir para a manutenção dos processos ligados a manutenção do elo microbiano do reservatório de Barra Bonita.
113

Treinamento intervalado no limite inferior e superior do domínio severo: Efeitos sobre variáveis fisiológicas e desempenho no ciclismo / Interval training at lower and upper boundary of severe domain: Effects on physiological variables and performance in cycling

Turnes, Tiago 05 June 2013 (has links)
Made available in DSpace on 2016-12-06T17:06:56Z (GMT). No. of bitstreams: 1 Tiago Turnes.pdf: 566528 bytes, checksum: de1b9403dc58334cab95ace0bfee45aa (MD5) Previous issue date: 2013-06-05 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to observe the effects of training performed at the lower and upper boundary of severe intensity domain on physiological variables and performance on cycling. After an incremental test, and determination of critical power (PC) and determination of the highest intensity in which VO2max is attained (ISUP), Wingate test and 250kJ time-trial, the subjects were devised in two training groups, that were performed three times for week, for a four weeks period. A group trained on intensity 5% above PC (105%PC group, n = 8) and the other on ISUP intensity (ISUP group, n = 8). The ISUP session training provoked higher blood lactate concentration, heart rate and time near VO2max than 105%PC group (p &#8804; 0.05), with no differences in total work performed on training session between groups. The ISUP and 105%PC improved equally (p < 0.05) the higher intensity in incremental test (ISUP: 266 ± 40; 294 ± 38W vs. 105%PC: 254 ± 36; 283 ± 32W), anaerobic threshold (ISUP: 154 ± 42; 184 ± 36W vs. 105%PC: 145 ± 44; 170 ± 31W), PC (ISUP: 209 ± 47; 233 ± 35W vs. 105%PC: 198 ± 26 vs. 222 ± 28W), ISUP (ISUP: 338 ± 51; 357 ± 51W vs. 105%PC: 319 ± 33; 340 ± 33W), relative VO2max (ISUP: 47.5 ± 5.7; 50.7 ± 6.9ml.kg.min-1 vs. 105%PC: 47.2 ± 3.9; 48.8 ± 3.7ml.kg.min-1) and 250-kJ time-trial performance (ISUP: 1137 ± 217; 1019 ± 182s vs. 105%PC: 1188 ± 180; 1072 ± 171s). Both groups had no changes on work capacity above PC, lowest exercise duration in which VO2max is attained and fatigue index in Wingate test (p > 0.05). Only ISUP group improved the absolute VO2max (ISUP: 3558 ± 446; 3790 ± 496 ml.min-1 vs. 105%PC: 3638 ± 388; 3708 ± 390ml.min-1), lactate threshold (ISUP: 66 ± 27 ; 98 ± 28W vs. 105%PC: 69 ± 18; 100 ± 20W) and peak (ISUP: 894 ± 111; 951 ± 124W vs. 105%PC: 918 ± 119; 924 ± 122W) and mean (ISUP: 705 ± 65; 743 ± 79W vs. 105%PC: 729 ± 79; 736 ± 81W) power of Wingate test (p < 0.05). In conclusion, the highest and the lowest intensity of severe domain were equally efficient to improve the aerobic indexes and aerobic performance of middle duration (~18min). However, only the training on the upper boundary of severe domain improves VO2max and anaerobic parameters of Wingate test. Therefore, ISUP training seems to be more advantageous compared to 105%PC when the aim is improve the anaerobic performance in cycling. / O objetivo deste estudo foi observar os efeitos do treinamento intervalado realizado no limite inferior e superior do domínio severo sobre variáveis fisiológicas e desempenho no ciclismo. Após teste incremental, determinação da potência crítica (PC) e da maior intensidade em que o VO2max é alcançado (ISUP), teste de Wingate e Contra-relógio de 250kJ, os sujeitos foram divididos em dois grupos de treinamento, que foi realizado três vezes por semana, em um período de quatro semanas. Um grupo treinou em intensidade 5% acima da PC (Grupo 105%PC, n = 8) e outro na intensidade de ISUP (Grupo ISUP, n = 8). A sessão de treinamento na ISUP provocou maiores concentrações de lactato sanguíneo, frequência cardíaca e tempo próximo ao VO2max comparado ao grupo 105%PC (p &#8804; 0,05), sem diferenças no trabalho total realizado nas sessões de treinamento entre os grupos. Os grupos ISUP e 105%PC obtiveram similar adaptação (p < 0,05) na potência pico do teste incremental (ISUP: 266 ± 40; 294 ± 38W vs. 105%PC: 254 ± 36; 283 ± 32W), limiar anaeróbio (ISUP: 154 ± 42; 184 ± 36W vs. 105%PC: 145 ± 44; 170 ± 31W), PC (ISUP: 209 ± 47; 233 ± 35W vs. 105%PC: 198 ± 26 vs. 222 ± 28W), ISUP (ISUP 338 ± 51; 357 ± 51W vs. 105%PC: 319 ± 33; 340 ± 33W), VO2max relativo (ISUP: 47,5 ± 5,7; 50,7 ± 6,9ml/kg/min-1 vs. 105%PC: 47,2 ± 3,9; 48,8 ± 3,7ml/kg/min-1) e tempo de prova de contra-relógio de 250kJ (ISUP: 1137 ± 217; 1019 ± 182s vs. 105%PC: 1188 ± 180; 1072 ± 171s). Ambos os grupos não provocaram adaptações na capacidade de trabalho acima da PC, menor tempo em que o VO2max é alcançado e índice de fadiga do teste de Wingate (p > 0,05). Apenas o grupo ISUP provocou melhoras significantes no VO2max absoluto (ISUP: 3558 ± 446; 3790 ± 496 ml/min-1 vs. 105%PC: 3638 ± 388; 3708 ± 390ml/min-1), limiar de lactato (ISUP: 66 ± 27; 98 ± 28W vs. 105%PC: 69 ± 18; 100 ± 20W) e potência pico (ISUP: 894 ± 111; 951 ± 124W vs. 105%PC: 918 ± 119; 924 ± 122W) e média (ISUP: 705 ± 65; 743 ± 79W vs. 105%PC: 729 ± 79; 736 ± 81W) do teste de Wingate (p < 0,05). Em conclusão, a maior e menor intensidade do domínio severo foram de igual eficiência para melhora nos principais índices fisiológicos aeróbios como no desempenho aeróbio de média duração (~18min). Entretanto, apenas o grupo de treinamento no limite superior do domínio severo provocou melhoras nos parâmetros anaeróbios no teste de Wingate. Dessa forma, o treinamento na ISUP parece ser vantajoso em relação a 105%PC quando o objetivo do treinamento é melhorar também o desempenho anaeróbio no ciclismo.
114

Efeito do tratamento com exercício físico na capacidade funcional em tabagistas com doença arterial coronariana / Effect of treatment on exercise capacity in funcional in smohing with coronary artery disease

Garcia, Roberto Carlos Barrera 08 April 2010 (has links)
Made available in DSpace on 2016-12-06T17:07:25Z (GMT). No. of bitstreams: 1 Roberto.pdf: 812217 bytes, checksum: 027fe32205ab5a47b3a3381ae6cefbcc (MD5) Previous issue date: 2010-04-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Cigarette smoking is identified as a risk factor for six of the eight leading causes of death in the world, with one death recorded every six seconds. Cardiovascular diseases such as coronary artery disease (CAD) is a possible consequence of smoking. In addition to harming the physical activity, smoking affects the functional capacity expressed in the decrease of maximal oxygen uptake (VO2max). Although it is known that aerobic exercise improves VO2max with functional capacity, there are few studies that deal with the effect of aerobic exercise in smokers and systemic levels of VO2max. The objective of this study was to evaluate the effects of treatment with aerobic exercise on functional capacity in smokers with CAD. This retrospective trial was performed from the database Cardiosport Clinic in Florianopolis / SC, previously approved by the Ethics Committee. A systematic random sample (n = 27) consisted of male smokers with coronary artery disease (CAD) diagnosed with at least ten years of smoking, with a mean age of 61 years (± 8 years) and body mass index (BMI) to 27 (23-31), patients were divided into two distinct groups, one control group with abstinence and untrained (GC) and an experimental group without withdrawal and aerobic training (GE). The variable analyzed for assessment of functional capacity was VO2max. Statistical analysis showed an increase in VO2max in the GE of 20.33 (17,50-38,70) to 21.00 (17,10-44,20) ml/kg-1/min-1 considered statistically significant. In the CG there was no significant increase, obtaining values of 27.10 (17,00-31,90) to 27.40 (16,50-32,20) ml/kg-1/min-1 pre and post tests respectively, and p = 0.05 for both groups. We conclude that although the increase in VO2max in GE has been significant, these values remain in the lower ratings of functional capacity levels for healthy people, and the abstinence from smoking during eight weeks results in improvement of VO2max. Aerobic exercise improves functional capacity in smokers with CHD over a period of eight weeks. / O tabagismo é identificado como fator de risco entre seis das oito principais causas de morte no mundo, com um óbito registrado a cada seis segundos. As doenças cardiovasculares como a doença arterial coronariana (DAC) é uma possível consequência do consumo do tabaco. Além de prejudicar as atividades físicas, o tabagismo afeta a capacidade funcional expressada na diminuição do consumo máximo de oxigênio (VO2máx). Embora seja conhecido que o exercício físico aeróbio aprimora o VO2máx junto com a capacidade funcional, são poucos os estudos que tratam sobre o efeito do exercício aeróbico sistemático em fumantes e seus níveis de VO2máx. O objetivo deste trabalho foi avaliar os efeitos do tratamento com exercício físico aeróbico sobre capacidade funcional em tabagistas com DAC. Esta pesquisa retrospectiva experimental foi realizada a partir do banco de dados da Clínica Cardiosport em Florianópolis/SC, previamente aprovada pelo Comitê de Ética. A amostra casual sistemática (n=27) foi composta por homens tabagistas com doença arterial coronariana (DAC) diagnosticada com pelo menos dez anos de fumo, apresentando idade média de 61 anos (±8 anos) e índice de massa corporal (IMC) igual a 27 (23-31), Os pacientes foram divididos em dois grupos distintos, sendo um grupo controle com abstinência e sem treinamento (GC) e um grupo experimental sem abstinência e com treinamento aeróbico (GE). A variável analisada para avaliação da capacidade funcional foi o VO2máx. As estatísticas evidenciaram um aumento no VO2máx no GE de 20,33 (17,50-38,70) para 21,00 (17,10-44,20)ml/kg-1/min-1 considerado estatisticamente significativo (p=0.002). No grupo GC não se observou aumento significativo, obtendo valores de 27,10 (17,00-31,90) para 27,40 (16,50-32,20) ml/kg-1/min-1 pré e pós testes respectivamente, Considerando o p=0,05 para ambos os grupos. Conclui-se que embora o aumento no VO2máx no GE tenha sido significativo, tais valores permanecem nas classificações mais baixas dos níveis de capacidade funcional para pessoas saudáveis, e que a abstinência do fumo por oito semanas no resulta em aprimoramento do VO2máx. O exercício físico aeróbico melhora a capacidade funcional em pacientes tabagistas com DAC num período de oito semanas.
115

Respostas cardiorrespiratórias e neuromusculares da corrida estacionária em diferentes cadências nos meios aquático e terrestre / Cardiorespiratory and neuromuscular responses to stacionary running at different cadences in aquatic and terrestrial environments

Alberton, Cristine Lima January 2007 (has links)
O objetivo do presente estudo foi analisar as respostas cardiorrespiratórias, cinemáticas e neuromusculares de mulheres jovens realizando o exercício de corrida estacionária em diferentes cadências nos meios aquático e terrestre. Doze mulheres jovens, experientes na prática de hidroginástica, foram amostras voluntárias do estudo. Cada uma participou de duas sessões experimentais: 1) coleta dos dados de caracterização da amostra e realização de um teste de esforço máximo; 2) coleta das variáveis cardiorrespiratórias (freqüência cardíaca (FC), consumo de oxigênio (VO2), percentual da FC máxima (%FCmáx) e percentual do VO2 máximo (%VO2máx)), cinemáticas (velocidade angular média (VAMQ) e de pico do quadril (VAPQ)) e neuromusculares (amplitude do sinal eletromiográfico (EMG) dos músculos vasto lateral (VL), bíceps femoral (BF), reto femoral (RF) e semitendinoso (ST)). Para a coleta de tais variáveis, dois protocolos de testes foram realizados, um no meio terrestre e outro no meio aquático, com um intervalo de duas horas entre eles. Para cada um dos meios, o exercício de corrida estacionária foi realizado durante 4 min em 3 cadências submáximas (60, 80 e 100 bpm) e durante 15 s no máximo esforço, com um intervalo de 5 min entre cada situação. Utilizamos análise de variância com bloqueamento, considerando o efeito do sujeito como mais uma fonte de variação para a análise estatística, com os dados processados nos programas SPSS versão 13.0 e R-project. Como resultados, as variáveis VAMQ e VAPQ foram significativamente mais elevadas quando o exercício foi executado no meio terrestre, e maiores quanto maior a cadência de execução, sugerindo um padrão cinemático distinto entre os meios. Da mesma forma, as respostas cardiorrespiratórias foram maiores para o exercício no meio terrestre e aumentaram significativamente com o aumento da cadência de execução. Já as respostas neuromusculares não apresentaram um comportamento semelhante, visto que o sinal EMG dos músculos VL, BF, RF e ST não aumentou significativamente com o incremento da cadência de execução, exceto das cadências submáximas para o máximo esforço. Na comparação entre os meios, o meio terrestre apresentou respostas significativamente maiores para o sinal EMG de todos os músculos nas cadências submáximas, exceto para o músculo ST que apresentou respostas semelhantes. Entretanto, no máximo esforço todos os grupos musculares analisados apresentaram respostas similares entre os meios. Em suma, a realização do exercício de corrida estacionária no meio aquático em cadências de execução submáximas apresenta respostas cardiorrespiratórias e neuromusculares menores do que o mesmo executado no meio terrestre, para as cadências fixas do presente estudo. Todavia, em intensidades máximas, a amplitude do sinal EMG pode apresentar padrões de ativação muscular semelhante entre os meios. / The aim of the present study was to analyze the cardiorespiratory, kinematic and neuromuscular response of young women performing stationary running exercise at different cadences in aquatic and terrestrial environments. The study sample consisted of twelve young women, experienced in hydrogymnastics. Each one took part in two experimental sessions: 1) collection of sample characterization data and the performance of a maximum effort test; 2) collection of the cardiorespiratory (heart rate, (HR), oxygen uptake (VO2), percentage of maximum HR (%HRmax) and percentage of maximum VO2 (%VO2max)), kinematic (mean hip angular velocity (MHAV) and peak hip angular velocity (PHAV)), and neuromusuclar variables (electromyographic signal amplitude (EMG) of the vastus lateralis (VL), biceps femoris (BF), rectus femoris (RF) and semitendinosus (ST) muscles). In order to collect these variables, two test protocols were carried out, one land-based and the other water-based, with a two-hour interval between them. The stationary running exercise was performed in each of these environments during 4 min at 3 submaximal cadences (60, 80, and 100 bpm) and during 15 s at maximum effort, with a 5 min-interval between each situation. We used blocked variance analysis, in which the effect of the subject was considered an additional source of variation for the statistical analysis. The data was processed using the SPSS (version 13.0) and R-project programs. The findings showed that the MHAV and PHAV were significantly higher when the exercise was performed on land, and higher the greater the cadence of execution, suggesting distinct kinematic patterns for the two environments. Similarly, the cardiorespiratory responses were higher with the land-based exercise and increased significantly with increased cadence. The neuromuscular responses, however, showed no such behavior, with the EMG signal from the VL, BF, RF and ST muscles showing no significant increase with greater cadence of execution, except from the sub-maximum cadences to the maximum effort. When comparing the environments, the terrestrial environment presented significantly greater EMG signal responses from all the muscles at the sub-maximum cadences, except for the ST muscle which presented similar responses in both environments. However, at the maximum effort, all the analyzed muscle groups showed similar responses in both environments. In summary, at the cadences used in the present study, the performance of the stationary running exercise in an aquatic environment at a sub-maximum cadences presents lower cardiorespiratory and neuromuscular responses than the same exercise performed on land. Yet, at maximum intensities, the amplitude of the EMG signal may present similar muscular activation patterns in the two environments.
116

Efeitos do treinamento com pesos sobre a densidade mineral ossea, força muscular e variaveis funcionais na menopausa / Response of the resting metabolic rate, bone mineral density, muscle strength and oxygen uptake after 16 week resistance training in postmenopausal women

Bonganha, Valeria, 1981- 14 August 2018 (has links)
Orientador: Vera Aparecida Madruga / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-08-14T00:30:49Z (GMT). No. of bitstreams: 1 Bonganha_Valeria_M.pdf: 3256322 bytes, checksum: 91deeb15b9570006ec9f1e2bf73ec3ee (MD5) Previous issue date: 2009 / Resumo: O presente estudo analisou as respostas dos indicadores de força, densidade mineral óssea (DMO), taxa metabólica de repouso (TMR), composição corporal e capacidade aeróbia (O2 máximo e limiar anaeróbio) após intervenção de 16 semanas de treinamento com pesos (TP). Participaram desta pesquisa 22 voluntárias, na pós-menopausa (12 meses sem menstruações) subdivididas em dois grupos: grupo treinado (GT n=12) e grupo controle (GC n=10). O programa de TP teve freqüência de três sessões semanais em dias alternados, compreendendo 10 exercícios para membros superiores, inferiores e tronco, sendo realizado três séries de 10 repetições máximas (RM) na etapa 1 e três séries de 8 RM na etapa 2. Os níveis de força foram mensurados pelo teste de 1-RM, a composição corporal foi obtida pelo método de espessura de dobras cutâneas, a avaliação da DMO foi realizada por Densitometria Radiológica de Dupla Energia nas regiões da coluna lombar e colo do fêmur, a TMR e o O2 máximo foram obtidos por meio de calorimetria indireta, sendo a TMR calculada por meio da equação de Weir (1949). O O2 máximo foi obtido durante teste de esforço progressivo em esteira até a exaustão. Para análise dos dados foi utilizado o teste de Kruskal-Wallis, para avaliar os efeitos do TP intra e intergrupos e a correlação de Spearman nas correlações utilizadas. Os resultados encontrados mostraram aumentos com diferenças estatisticamente significantes para as cargas levantadas nos testes de 1-RM para supino e leg press no GT e nenhuma modificação foi encontrada para o GC. Não foram obtidas diferenças significantes para os valores de DMO, tanto da coluna quanto do fêmur, da TMR e do O2 pico e limiar anaeróbio em ambos os grupos. O treinamento com pesos foi eficaz para aumentar a força muscular, entretanto 16 semanas de intervenção não foram suficientes para provocar alterações significantes na DMO, na TMR e na capacidade aeróbia. / Abstract: This study examined the adaptive responses of indicators of strength, bone mineral density (BMD), the resting metabolic rate (RMR) and aerobic capacity (O2 max and anaerobic threshold ) after 16 weeks intervention resistance training program (RT). Participated 22 postmenopausal women (12 months without menstruation), subdivided in two groups: trained group (GT n = 12) and control group (GC n = 10). The RT period had frequency of three sessions per week on alternate days, with 10 exercises for upper limbs and lower limbs, and performed three sets of 10 repetitions maximum (RM) in step 1 and three sets of 8 RM in step 2. The levels of strength were measured by the 1-RM test, body composition was obtained by the method of skinfolds, the assessment of BMD was performed by densitometry of Radiological Dual Energy in the regions of lumbar spine and the femoral neck, and the RMR and O2 max were obtained by indirect calorimetry and the RMR calculated using equation of Weir (1949). The O2 max was obtained during progressive test on a treadmill until exhaustion. For statistical analysis we used the Kruskal-Wallis test to assess the effects of intra and inter RT and the Spearman correlation to the correlations used. The results showed statistically significant differences increase for the load being strength in the 1-RM tests and supine leg press for the GT and no change was found to GC. No significant differences were obtained for the BMD of the spine on both the femur, O2 peak and the TMR in both groups. RT was effective to increase muscle strength, but 16 weeks were not sufficient to cause changes in BMD, in TMR and aerobic capacity. / Mestrado / Atividade Fisica, Adaptação e Saude / Mestre em Educação Física
117

Avaliação em bancada do desempenho de sete diferentes marcas de ressuscitadores manuais auto-inflaveis para adultos produzidos e/ou comercializados no Brasil / Evaluation of the performance of seven different marks of self-inflating resuscitator bags for adults manufacturing and/or commercialization in Brazil

Godoy, Armando Carlos Franco de 10 January 2007 (has links)
Orientador: Ronan Jose Vieira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-09T10:43:00Z (GMT). No. of bitstreams: 1 Godoy_ArmandoCarlosFrancode_D.pdf: 1391626 bytes, checksum: 600da181d72c7d389f13d631605e7c01 (MD5) Previous issue date: 2007 / Resumo: Esta pesquisa foi realizada como o objetivo de verificar se a fisioterapia respiratória favorece o surgimento de refluxo gástrico de dieta enteral para a cavidade orofaríngea em pacientes adultos, sedados, portadores de via aérea artificial e necessitando ventilação mecânica. Efetuou-se um estudo experimental prospectivo, utilizando-se o modelo estatístico caso-controle, empregou-se grupo experimenta~ o qual os pacientes recebiam tratamento fisioterápico e o grupo controle, o qual os pacientes não recebiam tratamento fisioterápico. A amostra foi composta por 20 pacientes em cada grupo, os quais recebiam dieta enteral por sonda de alimentação alocada no estômago. Utilizou-se como marcador do refluxo gástrico de dieta enteral o corante azul-de-metileno, injetado no intervalo entre a metade e a outra metade do volume total de dieta enteral infundida. Se os pacientes apresentassem colorações azuladas em suas secreções orofaríngeas, verificado por três profissionais da saúde no final do experimento, estaria evidenciado o refluxo de dieta enteral. Ao final de cada experimento, tanto no grupo controle como no grupo experimenta não foram encontradas, secreções azuladas, em nenhum paciente durante as inspeções da sua cavidade orofaríngea. Este fato nos permitiu concluir que a fisioterapia respiratória, neste grupo de pacientes, não propicia o refluxo de dieta enteral para a cavidade orofaríngea / Abstract: This research was carried through as the objective to evaluate the gastric index of reflux of enteral diet for the orofaringea socket caused by the respiratory therapeutic handling in adult patients, sedated, intubated and needing ventilation mechanics. A prospective experimental study was effected, using the statistical model case-control, was used the experimental group has controlled, which the patients did not receive handling physical therapy. The sample was composed of 20 patients who received enteral diet for sounding lead of feed leased in the stomach. The blue-of-methylene was used as marking of gastric reflux of enteral diet, which was introduced in the interval between the half and to another half of the total volume of the enteral diet. If the patients presented bluish coloration in its orofaringeas secretions; in the end of the experiment, were evidenced refluxes of enteral diet. To the end of each experiment, as much in the group has controlled as in the experimental group, nothing was found in any patient, during the inspections of itsorofaringeas sockets, bluish secretions. This fact led us to the conclusion that the physical therapy in this specific group of patients was not appropriate for the reflux of enteral diet for the orofaringea socket / Doutorado / Ciencias Basicas / Doutor em Clínica Médica
118

Projeto multicentrico em fisiologia do exercicio : etapa de calibração de cicloergometros / Physiogy of exercice multicentre project : cycle calibration stage

De Bellis Silva, Gerson 27 June 2008 (has links)
Orientador: Luiz Eduardo Barreto Martins / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-08-11T15:22:06Z (GMT). No. of bitstreams: 1 DeBellisSilva_Gerson_M.pdf: 2066470 bytes, checksum: ddc04339cfa1c1fb8ea3d1fb4616ea56 (MD5) Previous issue date: 2008 / Resumo: Nesse projeto multicêntrico em fisiologia do exercício - etapa de calibração de cicloergômetros foi desenvolvido um calibrador de cicloergômetros que pode ser utilizado com modelos diferentes de cicloergômetros. A partir de sua calibração estática constatou-se que o mesmo foi capaz de mensurar potencia em cicloergômetros com precisão de 0,85 W. Foi realizada a calibração dinâmica de três cicloergômetros de mesmo modelo que são utilizados pelos laboratórios de fisiologia do exercício da Faculdade de Educação Física da UNICAMP, do Departamento de Fisioterapia da UFSCar e do Departamento de Clinica Médica da USP de Ribeirão Preto. O experimento de calibração testou a resistência, estabilidade e a robustez dos cicloergômetros, além de fornecer a equação que relaciona a potencia real e a potencia indicada pelos cicloergômetros nas rotações de 45, 60 e 75 rpm. As inclinações calculadas pelas regressões foram 0.992, 0.991 and 0.977 respectivamente. Aplicaram-se testes ergoespirométricos em três voluntários nas potencias corrigidas de 60 e 120 W por 10 minutos em cada um dos laboratórios citados. Os valores de consumo de oxigênio, produção de CO2, ventilação e freqüência cardíaca foram calculados no regime permanente e suas medianas comparadas. Os resultados foram diferentes (p<0.05) para as comparações diretas, porém suas variações entre os dois níveis de esforço foram semelhantes. Os testes possibilitaram a observação de que a magnitude da variabilidade biológica dos dados fisiológicos se sobrepõe a precisão mecânica dos ergômetros utilizados nestes testes. Conclui-se que os cicloergômetros calibrados estão adequados ao propósito de um projeto multicêntrico, porém os procedimentos experimentais que envolvem a variabilidade biológica ainda necessitam de padronização para tornar possível agrupar dados coletados nos diferentes Laboratórios / Abstract: In the Multicenter Exercise Physiology Project: cycle ergometer calibration phase a multiple kind cycle ergometer calibrator was developed. The exercise physiology laboratories comprising the multicenter project were from Faculty of Physical Education- UNICAMP, Department of Physical Therapy UFSCar and Department of internal medicine- USPRP. Its static calibration gave an accuracy of 0.85 W for cycle ergometer workload readout. An experimental setup for testing stability, resistance and robustness of cycles was carried out in three identical model cycle ergometers. The dynamical calibration was executed to provide the linear regression equation between actual and indicated workloads for 45, 60 and 77 rpm. The computed regressions slopes were 0.992, 0.991 and 0.977 respectively. Ergospirometric tests with 60 and 120 W of workload were applied to three volunteers for 10 min in each laboratory. Oxygen uptake, CO2 production, ventilation and heart rate were computed for steady state and their medians tested for statistical significance (P<0.05). The results were different for direct testing of variables, although their between exercise levels variations were equal. Though, the biological variability overlaps the mechanical accuracy of ergometers. In conclusion, the calibration procedure of ergometers allows the constitution of a multicenter project but biological variability associated with the ergospirometric tests needs standardization to permit the grouping of data from different Laboratories / Mestrado / Biodinamica do Movimento Humano / Mestre em Educação Física
119

Consumo de oxigênio de amputados traumáticos transtibiais no repouso e exercício

Garcia, Marília Mendes do Nascimento 15 May 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-11T18:15:59Z No. of bitstreams: 1 mariliamendesdonascimentogarcia.pdf: 3241001 bytes, checksum: a1cee556b27ae439afc5e2b3142d4e76 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-27T19:25:41Z (GMT) No. of bitstreams: 1 mariliamendesdonascimentogarcia.pdf: 3241001 bytes, checksum: a1cee556b27ae439afc5e2b3142d4e76 (MD5) / Made available in DSpace on 2016-06-27T19:25:41Z (GMT). No. of bitstreams: 1 mariliamendesdonascimentogarcia.pdf: 3241001 bytes, checksum: a1cee556b27ae439afc5e2b3142d4e76 (MD5) Previous issue date: 2013-05-15 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Introdução: A marcha de amputados de membros inferiores (MMII) envolve maior consumo de oxigênio (VO2), justificado por meio das alterações biomecânicas. Apesar dos estudos não associarem as variáveis cardiovasculares e a capacidade física com o maior VO2 durante a marcha de amputados de MMII, esses indivíduos possuem alterações autonômicas e cardiovasculares em repouso e diminuição da capacidade aeróbia. Objetivo: Testar a hipótese que os amputados transtibiais traumáticos apresentam maior VO2 em repouso, que, associado às alterações cardiovasculares, interferem no VO2 durante a marcha e exercício aeróbio envolvendo os membros superiores. Métodos: Foram avaliados 22 indivíduos adultos, do sexo masculino, 11 com amputações transtibiais unilaterais traumáticas, comparados a 11 indivíduos sem amputações. Os voluntários foram avaliados em relação à frequência cardíaca (FC), pressão arterial (PA) e VO2, este por meio do analisador de gases K4 b² Cosmed. Todos os indivíduos foram avaliados em repouso, na postura supina e ortostática, em um protocolo de marcha na esteira rolante e em um protocolo contínuo no cicloergômetro de membros superiores (MMSS). Para comparação entre os grupos, foi utilizado o teste t de Student e o de Mann Whitney, este para o VO2 e, para correlacionar as variáveis, a Correlação de Spearman (p<0,05). Resultados: Na postura supina e ortostática, os amputados apresentaram maiores valores de PA, FC e VO2. O VO2 obtido na postura ortostática dos amputados foi correlacionado de forma positiva com a FC obtida nessa postura e com o VO2 em supino. Durante a marcha, os amputados apresentaram maior FC, PA, VO2 e este correlacionou-se positivamente com o VO2 na postura supina e com a FC durante a marcha. Durante o protocolo contínuo de MMSS, os amputados apresentaram maior VO2 e PAS. Conclusão: Os amputados transtibiais traumáticos apresentaram alterações cardiovasculares e metabólicas em repouso, que interferiram no VO2 durante a marcha e postura ortostática. Confirmando a presença de alterações não mecânicas, relacionadas ao VO2, os amputados transtibiais também apresentaram maior VO2 e FC durante a atividade aeróbia que não envolveu os MMII. / Introduction: The gait of lower limb amputees involves a higher oxygen consumption (VO2), justified by the biomechanical alterations. Although the studies do not associate the cardiovascular variables and the physical capacities with the higher VO2 during the gait of lower limb amputees, these subjects have autonomic and cardiovascular alterations in rest and decrease in the aerobic capacity. Aim: Test the hypothesis that the transtibial traumatic amputees show higher VO2 at rest, which associated with cardiovascular alterations, interfere on the VO2 during the gate and aerobic exercise involving the upper limbs. Methods: Were assessed 22 adult subjects, male, 11 with one-sided transtibial traumatic amputations, compared to 11 subjects with no amputations. The volunteers were assessed through the heart rate (HR), blood pressure (BP) and VO2, by the gases analyzer K4 b² Cosmed. All the subjects were assessed in rest, in the supine and orthostatic position, in a gait protocol on the treadmill and in a continuous protocol on the upper limbs cycle ergometer. For comparison between the groups, were used the t-Student and the Mann Whitney tests, for the VO2, and to correlate the variables, the Spearman Correlation. Results: On the supine and orthostatic position, the amputees showed higher values of BP, HR and VO2. The VO2 obtained on the amputees’ orthostatic position was correlated positively with the HR obtained in this position and with the VO2 in supine. During the gait, the amputees showed higher HR, BP and VO2, this correlated positively with the VO2 on the supine position and with the HR during the gait. During the continuous protocol of upper limbs, the amputees showed higher VO2 and BP Conclusion: The transtibial traumatic amputees showed cardiovascular and metabolic alterations at rest, which interfered in the VO2 during the gait and orthostatic position. Confirming the presence of non mechanic alterations, related to the VO2, the transtibial amputees also showed higher VO2 and HR during the aerobic activity that did not involve the lower limbs.
120

Variáveis de controle do esforço em bicicleta aquática

Martins, Jonas Almeida Neves 20 April 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-10-03T12:15:23Z No. of bitstreams: 1 jonasalmeidanevesmartins.pdf: 670644 bytes, checksum: 679ac9b33c9908bca7ef8da0cda4dd02 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2016-10-03T15:16:49Z (GMT) No. of bitstreams: 1 jonasalmeidanevesmartins.pdf: 670644 bytes, checksum: 679ac9b33c9908bca7ef8da0cda4dd02 (MD5) / Made available in DSpace on 2016-10-03T15:16:49Z (GMT). No. of bitstreams: 1 jonasalmeidanevesmartins.pdf: 670644 bytes, checksum: 679ac9b33c9908bca7ef8da0cda4dd02 (MD5) Previous issue date: 2010-04-20 / A bicicleta aquática Hidrocycle® possui sistema para gerar resistência, denominado Evolution®, que consiste em quatro calhas retangulares dispostas perpendicularmente movimentadas pelo giro dos pedais. Neste sistema há duas maneiras para controlar a carga: 1) velocidade de pedalada (RPM) e 2) alteração da área frontal das calhas (AF) em três níveis, AF1, AF2 e AF3. Para utilização mais precisa no treinamento, torna-se necessário o estudo das variáveis que atuam no controle da intensidade do exercício do sistema Evolution®, freqüência cardíaca (FC), percepção do esforço (PE), tensão muscular, consumo de oxigênio (VO2), gasto calórico e concentração de lactato [La] em resposta às variações de RPM e AF. Portanto, os objetivos do estudo foram verificar: 1) A resposta da FC e PE em teste progressivo de esforço realizado em duas profundidades, cicatriz umbilical e processo xifóide; 2) Identificar VO2max, [La]max, FCmax e PE para cada AF do sistema Evolution® em protocolo progressivo de cargas e predizer o gasto calórico e potência gerada protocolo de carga submáxima constante. Para o estudo 1, a amostra foi constituída por 10 homens e mulheres ativos, submetidos a dois testes progressivos, um em cada profundidade. Para o estudo 2, 15 homens, fisicamente ativos realizaram 3 testes máximos, um com cada AF e um teste de carga constante submáxima para predição do gasto calórico e potência gerada. No estudo 1, os valores máximos de FC e PE apresentaram diferenças estatisticamente significantes ao serem comparados nas duas profundidades. Já a FC por estágio de RPM, apresentou a partir do terceiro estágio tendência a ser mais alta, sendo evidente a diferença a partir do sétimo estágio na altura do processo xifóide. O estudo 2 verificou-se que não há diferença nos valores máximos de FC, VO2, [La] e PE nas 3 AF estudadas em teste máximo, porém os valores ocorrem em RPM diferentes, revelando que quanto maior a AF, menor é a RPM para se atingir os máximos para FC, VO2, [La1] e PE. Para o mesmo estudo, permitiu predizer o VO2 a partir das variáveis AF, RPM. Conclui-se que o sistema Evolution® da bicicleta aquática Hidrocycle® permite adequar a sobrecarga de exercício, assim como sua predição facilitando a aplicação do equipamento nas diversas áreas do treinamento físico. / The aquatic bicycle Hidrocycle® has a system to generate resistance, called Evolution®, which consists of four rectangular troughs arranged perpendicularly moved by the rotation of the pedals. In this system there are two ways to control the load: 1) the pedaling speed (rpm) and 2) change in the frontal area of ducting (AF) in three levels, AF1, AF2 and AF3. To use more precise training, it is necessary to study the variables that act in the control of exercise intensity Evolution® system, heart rate (HR), perceived exertion (PE), muscle tension, oxygen consumption (VO2) and lactate concentration [La] in response to changes in RPM and AF. Therefore, the objectives of the study were: 1) The response of HR and PE in the progressive effort test performed at two depths, umbilicus and xiphoid process, 2) Identify VO2max, [La]max, and PE for each AF system Evolution ® protocol in progressive loads and to predict the VO2. For study 1, the sample consisted of 10 active men and women who underwent two progressive tests, one in depth. For study 2, 15 men, physically active performed area submitted to 3 maximal tests, one each with AF and a test of submaximal constant workload to predict the caloric expenditure and power generated. In study 1, the maximum values of HR and PE showed no statistically significant differences when comparing the two depths. The HR for stage RPM, presented from the third stage tend to be higher in height of the xiphoid process. In study 2, there was no difference in the maximum values of HR, VO2, [La] and PE in 3 AF studied in maximal test, but the values occur at different rpm, showing that the higher the AF, the less RPM to achieve the maximum for HR, VO2, [La1] and PE. Since the study incremental load predicted VO2 from the variables AF, RPM. We conclude that the system Evolution ® aquatic bicycle Hidrocycle ® to tailor the exercise overload, as well as the prediction equity to facilitate the implementation of the equipment in the various areas of physical training.

Page generated in 0.0655 seconds