• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 238
  • 12
  • 12
  • 12
  • 12
  • 10
  • 10
  • 10
  • 10
  • 6
  • 2
  • 1
  • Tagged with
  • 246
  • 246
  • 87
  • 52
  • 46
  • 42
  • 32
  • 27
  • 26
  • 26
  • 24
  • 23
  • 22
  • 22
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Filme à base de quitosana comparado à gordura autógena na prevenção de aderências pós-laminectomia dorsal em coelhos / Film based on chitosan compared to autologous fat in the prevention of postoperative adhesions dorsal laminectomy in rabbits

GOMES, Filipe Augusto Sales 30 January 2009 (has links)
Made available in DSpace on 2014-07-29T15:07:54Z (GMT). No. of bitstreams: 1 dissertacao Filipe ciencia Animal - Clinica e Cirurgia Animal.pdf: 1546193 bytes, checksum: 01b61544014ff3cebd3f43ddb04b8408 (MD5) Previous issue date: 2009-01-30 / The adhesions formation after surgical procedures in the spine is a subject well studied in neurosurgery, according to the discomfort and postoperative pain suffered by patients. Several studies have been performed using anti-inflammatories, autologous grafts, xenografts and xenologer biomaterials and even in film form and gel with the aim of reducing or preventing adhesion formation. The aim of this study was to compare the film based on chitosan with autogenous fat in preventing dural adhesions in rabbits. This technique was compared to the technique used routinely by neurosurgeons who, in most cases, using autogenous fat. We used 24 adult male rabbits of New Zealand, and 15 and 30 days postoperatively (PO) the spinal cords of animals underwent myelography and histological evaluation. The animals were randomly divided equally into two groups (group G and Q), and further subdivided into four subgroups: G15, Q15, G30 and Q30 according to time points and the material used. In the group Q, a laminectomy performed between L1-L2 was occluded with the film based on chitosan and in the Group G the defect was repaired with autogenous free fat graft. In assessing myelography, there was a moderate compression of the column spinal cord both in group G as in group Q. In two rabbits of group Q the compression was attributed to severe disruption of the stabilization made with surgical steel wire. There was no significant difference (p ≤ 0.05) between groups and subgroups. After the pre-established postoperatively, fibrous adhesion from mild to intense between the dura and the implant was noted in animals from both groups, with fibrosis and collagen fibers interspread with the tissue and implant withought, no statistically significant difference (p ≤ 0.05) between groups and subgroups. There were cell infiltrates and giant cells that were more intense in the group Q. At 15 and 30 days postoperatively, the films based on chitosan were coated by inflammatory cells with areas of central necrosis. At 30 days postoperatively, the material had a fibrous capsule surrounding the inflammatory focus and the implant was noticed statistically significant (p ≤ 0.05) of 5% when comparing the groups and subgroups. Based on the results we can conclude that the film based on chitosan, as well as a free autogenous fat reduces the extent of dural adhesions in rabbits, however, the film based on chitosan as well as any foreign body, induces crhonic and intenses inflammatory responses in the rabbit / A formação de aderências após procedimentos cirúrgicos na coluna vertebral é um tema bastante estudado na neurocirurgia, em função do desconforto e dores pós-operatórias sofridas pelos pacientes operados. Diversos estudos já foram realizados utilizando antiinflamatórios, enxertos autólogos, heterólogos e xenólogos e ainda biomateriais na forma de filme e gel com a finalidade de reduzir ou prevenir a formação de aderências. O objetivo deste estudo foi comparar o filme à base de quitosana com a gordura autógena na prevenção de aderências durais em coelhos. Tal técnica foi comparada à técnica realizada rotineiramente pelos neurocirurgiões que, na maioria dos casos, utilizam a gordura autógena. Foram utilizados 24 coelhos da raça Nova Zelândia, machos, adultos, e após 15 e 30 dias de pós-operatório (PO) as medulas espinhais dos animais foram submetidas à avaliação mielográfica e histológica. Os animais foram distribuídos aleatoriamente em dois grupos (grupo G e grupo Q) de igual número, sendo posteriormente subdivididos nos subgrupos G15,Q15, G30 e Q30 de acordo com os momentos de avaliação e o material utilizado. Nos animais do grupo Q, a laminectomia realizada entre L1-L2 foi ocluida com o filme à base de quitosana e no grupo G o defeito foi reparado com enxerto de gordura autógena livre. Na avaliação mielográfica, foi observada compressão moderada na coluna dorsal da medula espinhal tanto nos animais do grupo G quanto nos animais do grupo Q. Em dois coelhos do grupo Q ocorreu compressão grave atribuída à ruptura da estabilização feita com fio de aço cirúrgico. Não foi observada diferença significativa (p≤0,05) entre os grupos e subgrupos. Decorridos os períodos pré-estabelecidos de PO, foi notado nos animais de ambos os grupos, aderência fibrosa de leve a intensa entre a dura-máter e o implante, com fibrose e fibras colágenas entremeadas ao tecido conjuntivo e implante, sem diferença estatística significativa (p≤0,05) entre os grupos e subgrupos. Verificou-se infiltrados celulares e células gigantes, sendo este achado mais intenso nos animais do grupo Q. Aos 15 e 30 dias de PO, os filmes à base de quitosana encontravam-se revestidos por células inflamatórias com áreas de necrose central. Aos 30 dias de PO, o material apresentava cápsula fibrosa circundando o foco inflamatório e o implante, tendo sido notada diferença estatística significância (p≤0,05) de 5%, quando comparados os grupos e os subgrupos entre si. Com base nos resultados pode-se concluir que o filme à base de quitosana, assim como a gordura autógena livre reduz a extensão das aderências durais em coelhos, porém, o filme à base de quitosana assim como todo corpo estranho, induz respostas inflamatórias tissulares crônicas e intensas no coelho
232

Influência do grau de especialização médica no diagnóstico de fraturas vertebrais benignas e malignas nas imagens de ressonância magnética / Influence of the degree of medical specialization in the diagnosis of benign and malignant vertebral fractures in magnetic resonance imaging

Iranilson Medeiros Germano dos Santos 02 June 2017 (has links)
As fraturas benignas osteoporóticas e malignas da coluna vertebral representam um desafio diagnóstico para os médicos especialistas. As fraturas benignas osteoporóticas ocorrem em virtude da fragilidade óssea da osteoporose e as fraturas malignas são secundárias a infiltração neoplásica. Estes dois grupos tem em comum o fato de acometerem predominantemente a população idosa. Alguns sinais radiológicos favorecem o diagnóstico de fraturas benignas osteoporóticas enquanto outros sinais de imagem favorecem o diagnóstico de fraturas malignas, no entanto nenhum sinal identificado nas imagens é específico. O propósito de realizar esse estudo foi identificar se o nível de formação médica dos radiologistas e ortopedistas (cirurgiões da coluna vertebral) exerce influência para o diagnóstico etiológico dessas fraturas nos exames de RM da coluna lombar, assim como avaliar o grau de concordância intra e interobservador para o diagnóstico de fraturas benignas por osteoporose e fraturas malignas. Foram incluídos no estudo de forma retrospectiva os exames de 63 pacientes consecutivos da rotina clínica do HCRP, realizados previamente por indicação clínica e com diagnóstico de fratura não traumática de corpo vertebral. Para avaliar a influência do nível de formação médica, quatro radiologistas e dois cirurgiões da coluna vertebral com diferentes níveis de formação realizaram avaliações de forma independente e as cegas em relação as demais leituras e em relação às informações do prontuário clínico. As imagens de RM anonimizadas e no formato DICOM foram avaliadas em workstation OsiriX. Os médicos observadores fizeram as leituras classificando cada vértebra da região lombar da seguinte forma: sem fratura, com fratura de características benignas ou com fratura de características malignas. Cada observador realizou duas leituras, com intervalo de 15 dias entre as leituras. O padrão de referência foi obtido a partir da avaliação pormenorizada do prontuário eletrônico de cada paciente realizada por médico radiologista sênior, a partir do Sistema de Informações do Hospital (HIS) e do Sistema Informatizado da radiologia (RIS), incluindo a biópsia com confirmação histopatológica nos casos de neoplasia e o seguimento clinico e laboratorial por pelo menos dois anos nos casos em que não houve indicação clínica de biópsia. Utilizando este padrão de referência foram calculadas para cada leitura, a sensibilidade, a especificidade, acurácia, valor preditivo positivo e negativo com intervalo de confiança (IC) 95%. Os resultados demonstram uma excelente concordância intraobservador e uma boa concordância interobservador, porém sem relevância estatística. Além disso, de uma forma geral a sensibilidade dos observadores para a detecção de fraturas malignas foi boa. A especificidade, acurácia e valor preditivo negativo foram elevados para todos os observadores. O valor preditivo positivo variou de moderado a substancial. Portanto, não houve influência do nível de formação médica para o desempenho diagnóstico na detecção de fraturas benignas osteoporóticas e fraturas malignas nas imagens de ressonância magnética. / Benign osteoporotic and malignant spinal fractures represent a diagnostic challenge for medical specialists. Osteoporotic benign fractures occur because of the bone fragility of osteoporosis and malignant fractures are secondary to neoplastic infiltration. These two groups have in common the fact that they affect predominantly the elderly population. Some radiological signs favor the diagnosis of benign osteoporotic fractures while other imaging signs favor the diagnosis of malignant fractures, however no signs identified in the images are specific. The purpose of this study was to identify whether the level of medical training of radiologists and orthopedists (spine surgeons) influences the etiological diagnosis of these fractures in lumbar spinal MRI (magnetic resonance imaging), as well as to evaluate the degree of intra and interobserver agreement for the diagnosis of benign fractures due to osteoporosis and malignant fractures. We retrospectively included the exams of 63 consecutive patients from the clinical routine of the HCRP, performed previously by clinical indication and with diagnosis of non-traumatic vertebral body fracture. To evaluate the influence of the level of medical training, four radiologists and two spine surgeons with different levels of training performed evaluations independently, without knowing the other readings and without the information in the medical record. The anonymized MRI in the DICOM format were evaluated in OsiriX workstation. Observer doctors did the readings by classifying each vertebra in the lumbar region as follows: no fracture, with fracture of benign features or with fracture of malignant characteristics. Each observer performed two readings, with a 15-day interval between readings. The reference standard was obtained from the detailed evaluation of each patient\'s electronic medical record by a senior radiologist, with the Hospital Information System (HIS) and the Computerized Radiology System, including biopsy with histopathological confirmation in cases of neoplasia and clinical and laboratory follow-up for at least two years in cases in which there was no clinical indication of biopsy. Using this reference standard, sensitivity, specificity, accuracy, positive and negative predictive value with 95% confidence interval (CI) were calculated for each reading. The results demonstrate excellent intraobserver agreement and good interobserver agreement, but without statistical relevance. In addition, the sensitivity of the observers for the detection of malignant fractures was generally good. The specificity, accuracy and negative predictive value were high for all observers. The positive predictive value ranged from moderate to substantial. Therefore, there was no influence of the level of medical training for diagnostic performance in the detection of benign osteoporotic fractures and malignant fractures in magnetic resonance imaging.
233

Incidência e fatores de risco para fratura vertebral por osteoporose em idosos brasileiros da comunidade: um estudo prospectivo de base populacional. São Paulo Ageing e Health (SPAH) Study / Vertebral fractures, Incidence and risk factors for osteoporotic vertebral fracture in low-income community-dwelling elderly: a population-based prospective cohort study in Brazil

Diogo Souza Domiciano 05 February 2015 (has links)
As fraturas vertebrais por osteoporose conferem risco aumentado de novas fraturas por fragilidade e maior mortalidade. Não há dados consistentes acerca da incidência de fratura vertebral osteoporótica em países de baixa/média renda, que têm experimentado aumento da expectativa de vida e envelhecimento populacional acelerado nas últimas décadas. Os objetivos deste estudo foram determinar a incidência de fratura vertebral osteoporótica, diagnosticada por radiografia, bem como identificar os principais fatores de risco para fratura em idosos brasileiros da comunidade, em um estudo coorte prospectivo de base populacional. Setecentos e sete indivíduos da comunidade, com 65 anos ou mais, foram avaliados através de radiografias da coluna vertebral obtidas no início do estudo e após um tempo médio de seguimento de 4,3 ± 0,8 anos. Nova fratura vertebral foi definida como uma alteração na morfologia vertebral resultando em maior grau de deformidade na segunda radiografia (graus 1-3), quando comparado com o exame inicial. Questionário (dados clínicos), medida da densidade mineral óssea (DMO) e exames laboratoriais foram realizados na avaliação inicial. Modelos de regressão multivariada de Poisson foram construídos para identificar os preditores independentes de fratura vertebral. Quatrocentos e quarenta e nove mulheres (72,9±4,8 anos) e 258 homens (72,3±4,7 anos) foram incluídos no estudo. A incidência de fratura vertebral ajustada para a idade foi 40,3/1000 pessoas-ano em mulheres e 30,6/1000 pessoas-ano em homens. Na análise multivariada três modelos possíveis de fatores de risco para fratura foram determinados em mulheres: 1. idade (RR 2,46, IC 95% 1,66-3,65, para cada aumento em 10 anos), fratura osteoporótica prévia (RR 1,65, IC 95% 1,00-2,71) e DMO da coluna lombar (RR 1,21, IC 95% 1,03-1,41, para cada redução de 1 DP na DMO); 2. idade (RR 2,25, IC 95% 1,52-3,34, para cada aumento em 10 anos) e DMO do colo do fêmur (RR 1,42, IC 95% 1,11-1,81, para cada redução de 1 DP na DMO); 3. Idade (RR 2,11, IC 95% 1,41-3,15, para cada aumento em 10 anos) e DMO do quadril total (RR 1,56, IC 95% 1,21-2,0, para cada redução de 1 DP na DMO). Em homens, o maior quartil de distribuição do telopeptídeo C-terminal (CTX) sérico (RR 1,96, IC 95% 0,98-3,91) e fratura prévia (RR 2,10, 95% CI 1,00-4,39) foram preditores de nova fratura vertebral, após ajustes para idade, peso e atividade física. Este é o primeiro estudo longitudinal que determinou a incidência de fratura vertebral em uma amostra de base populacional de idosos na América Latina. A frequência de fratura vertebral foi elevada nessa população. Idade, fratura prévia, DMO e marcadores bioquímicos da remodelação óssea foram preditores de nova fratura vertebral / Vertebral fractures are associated with increased future fracture risk and mortality. No data on incidence of osteoporotic vertebral fracture have been reported in low-income countries where the population\'s aging has been faster. Thus, we sought to describe the incidence and risk factors for radiographic vertebral fracture in a longitudinal prospective Brazilian population-based elderly cohort. 707 older adults (449 women and 258 men) were evaluated with spinal radiographs obtained at baseline and after a mean follow-up of 4.3 ± 0.8 years. New vertebral fracture was defined as distinct alteration in the morphology of vertebrae resulting in higher grade of deformity on the second radiograph when compared to the baseline radiograph. Clinical questionnaire, bone mineral density (BMD), and laboratory tests were performed at baseline. Multivariate Poisson regression models were used to identify independent predictors of fracture. The age-standardized incidence of vertebral fracture was 40.3/1,000 person-years in women and 30.6/1,000 in men. In women, three models of risk factors for fracture were fitted: (1) age (relative risks (RR) 2.46, 95 % confidence interval (CI) 1.66-3.65), previous osteoporotic fracture (RR 1.65, 95 % CI 1.00-2.71), and lumbar spine BMD (RR 1.21, 95 % CI 1.03-1.41); (2) age (RR 2.25, 95 % CI 1.52-3.34) and femoral neck BMD (RR 1.42, 95 % CI 1.11-1.81); (3) age (RR 2.11, 95 % CI 1.41-3.15) and total hip BMD (RR 1.56, 95 % CI 1.21-2.0). In men, the highest quartile of cross-linked C-telopeptide (CTx) (RR 1.96, 95 % CI 0.98-3.91) and prior fracture (RR 2.10, 95 % CI 1.00-4.39) were predictors of new vertebral fracture. This is the first population-based study to ascertain the incidence of vertebral fracture in elderly Latin Americans, confirming the high frequency of the disorder. Age, prior fracture, BMD, and bone turnover were predictors of the short-term incidence of vertebral fracture
234

Resultados da vertebroplastia percutânea na doença vertebral cervical / Results of percutaneous vertebroplasty in the cervical spine

Francisco José Arruda Mont'Alverne 17 November 2008 (has links)
A vertebroplastia percutânea (VP) consiste na injeção de polimetilmetacrilato (PMMA) no corpo vertebral para alívio da dor e estabilização vertebral, porém seu uso na região cervical é restrito. No intuito de avaliar a efetividade e a segurança da VP na região cervical (VPC), foram avaliados 75 pacientes que se submeteram à VPC (n=101) por doença maligna (n=69) ou hemangioma vertebral (n=6) no período de janeiro de 1994 a outubro de 2007. A VPC foi realizada por uma abordagem ântero-lateral guiada por fluoroscopia. A dor foi graduada por uma escala variando de 0 a 10. O seguimento clinico (período médio de 8,8 meses) foi obtido em 57 (76%) pacientes: 48 tiveram a VPC indicada para controle da dor e nove para estabilização vertebral. Os dados foram analisados de forma univariada e multivariada. A efetividade analgésica foi obtida em 37 (77,1%) dos 48 pacientes seguidos, tendo sido associada ao volume de cimento injetado (P=0,011) e ao preenchimento vertebral (P=0,007) na análise multivariada. A estabilidade vertebral foi observada em 55 (96,5%) dos 57 pacientes, não se correlacionando com as variáveis estudadas. A curva de ROC identificou o preenchimento vertebral como preditor da efetividade analgésica (P=0,008), sendo 50% o melhor ponto de corte para discriminar a maior probabilidade de efetividade analgésica (sensibilidade de 78,0% e especificidade de 62,5%). O extravasamento de cimento foi identificado em 83 (82,2%) das 101 vértebras tratadas não se correlacionando com as variáveis estudadas. As complicações clínicas foram detectadas em 13 (17,3 %) pacientes: complicações locais em 10 (13,3%) e sistêmicas em três (4%) pacientes. As complicações clínicas foram estatisticamente relacionadas à ruptura do muro posterior (P=0,026) e ao extravasamento de PMMA no plexo venoso transverso (P=0,023). A taxa de mortalidade e morbidade a longo termo foi de 1,3% (um paciente) e 1,3% (um paciente). Pode se inferir que a VPC é um procedimento efetivo e seguro, sem se negligenciar os riscos potenciais de complicações. O preenchimento vertebral e o volume de cimento foram associados à efetividade analgésica, mas não à estabilidade vertebral. O preenchimento vertebral teve o maior poder discriminatório da efetividade analgésica, tendo sido obtido com o ponto de corte de 50 % o melhor equilíbrio entre sensibilidade e especificidade para se determinar a efetividade analgésica / Percutaneous vertebroplasty (PV) consists of an injection of polymethylmethacrylate (PMMA) into the vertebral body for pain relief and spinal stabilization, however reports of PV in the cervical spine (CPV) are scarce in the literature. To evaluate the effectiveness and security of CPV, we evaluated 75 patients (mean age, 51.3 years) who underwent CPV (n=101) for malignancies (n=69) and vertebral hemangiomas (n=6) between January 1994 and October 2007. CPV was performed via an antero-lateral approach, using fluoroscopic guidance. Pain intensity was scored with a scale ranging from 0 to 10. Follow-up (mean time of 8.8 months) was avaible in 57 (76 %) patients: 48 of them had CPV indicated for pain control and nine for spinal stabilization. Data were analysed by means of univariate and multivariate analysis. Pain improvement was observed in 37 (77.1%) out of 48 followed patients and was correlated in multivariate analysis with cement volume (P=0.011) and with vertebral filling (P=0.007). Spinal stabilization was observed in 55 (96.5%) of 57 followed patients and was related with none of the evaluated variables. The ROC curve identified the vertebral filling as a good predictor of pain improvement (P=0.008). The best cut-off point to discriminate pain improvement was 50% of vertebral filling (78.0% sensitivity and 62.5% specificity). In 83 (82.2%) of the 101 treated vertebral levels, at least one type of PMMA leakage was found. None of the evaluated factors were related significantly to PMMA leakage. Clinical complications were detected in 13 (17.3%) patients: local complications in 10 (13.3%) patients and systemic clinical complications in three (4.0%) patients. Posterior wall disruption (P=0.026) and transverse venous PMMA leakage (P=0.023) were significantly associated with clinical complications. Long-term morbidity and mortality rate was 1.3% (one patient) and 1.3% (one patient). CPV is a safe and efficacious procedure, but the potential for local and systemic complications must be considered. Cement volume and vertebral filling were associated with pain improvement but not with spinal stability. Vertebral filling has a good performance to predict pain improvement and a cut-off of 50% of vertebral filing obtained the best compromise between sensitivity and specificity to discriminate pain improvement
235

Desenvolvimento de um sistema para avaliação dos desvios da coluna vertebral em três dimensões- Spine3D / Development of a new three-dimensional system for evaluating spine deformities - Spine3D

Thomaz Nogueira Burke 21 May 2013 (has links)
Introdução: Escoliose é definida como um complexo desalinhamento tridimensional da coluna vertebral na qual há o aparecimento de uma curvatura lateral no plano coronal, normalmente associada com o aplanamento das curvaturas no plano sagital e rotação vertebral em seu eixo longitudinal. O padrão ouro para seu diagnóstico e monitoramento é a medida radiográfica pelo ângulo de Cobb, que possui como principais desvantagens o fato de não avaliar as curvas em três dimensões e expor os pacientes, principalmente os que estão em fase de crescimento, a consideráveis doses de radiação. Objetivo: Esta pesquisa teve como objetivo principal o desenvolvimento de um sistema de avaliação e representação da coluna vertebral em três dimensões, capaz de possibilitar ao usuário a análise quantitativa dos desvios da coluna vertebral nos planos coronal, sagital e transverso. São objetivos secundários estimar a precisão e a exatidão do sistema proposto, e avaliar a sua aplicabilidade a partir de um estudo de caso. Métodos: O Sistema desenvolvido, denominado de Spine 3D, é baseado no uso do controle de videogame Wiimote para rastrear LEDs infravermelhos que compõe um marcador multiplanar em uma cena, e tem como objetivo reconstruir em um ambiente 3D a pose das vértebras torácicas e lombares e, com isto, obter as variáveis angulares e de translação que descrevem seu alinhamento nos planos coronal, sagital e transverso. O experimento para a avaliação da exatidão e precisão consistiu em posicionar o marcador a 50 centímetros de distância do Wiimote, ambos alinhados em um mesmo plano. O marcador foi transladado em intervalos de 10 mm e rotacionado em 5°, 10°, 20° e 30° nos eixos X, Y e Z, com auxílio de um inclinômetro e um paquímetro digital. Os dados foram coletados a 100 Hz. A exatidão foi calculada comparando os resultados encontrados pelo sistema com os valores obtidos pelo inclinômetro e paquímetro digital. A precisão foi calculada a partir do desvio-padrão dos pontos coletados. Resultados: A exatidão média do sistema foi de 0,90° e 0,78mm. A precisão média do sistema foi de 0,62° e 0,42mm. Para o ângulo de Cobb na escoliose, a exatidão e precisão foram de 1,46° e 1,72°, e para a cifose torácica e lordose lombar, a exatidão e precisão foram de 2,82° e 1,60°, respectivamente. Durante o estudo de caso, a diferença entre o Spine3D e a radiografia, para o ângulo de Cobb foi de 1,3° para escoliose curva torácica e 2,24° para escoliose curva lombar. Conclusão: O sistema mostrou ter boa exatidão e precisão após os testes de validação interna. O estudo de caso sugere que a técnica possui potencial para aplicação clínica na avaliação dos desvios da coluna vertebral em três dimensões. / Introduction: Scoliosis is a complex three-dimensional malalignment of the vertebral column in which there is lateral curvature of the spine in the coronal plane, usually associated with flattening of the contour in the sagittal plane and rotation of the vertebrae around their longitudinal axes. Routine clinical analysis of the scoliotic spine is currently based on the radiographic measurement of Cobb angle. Although considered as the golden standard, it has the disadvantage of look over only the two-dimensional aspects of the curve and, over a period of years, the patient will be exposed to a large dose of radiation, especially in early onset curves. There is evidence that this may increase the risk of developing several types of cancer. Objective: This paper describes a new low-cost and radiation-free system to evaluate the three-dimensional aspects of scoliosis, and its concurrent validation in terms of accuracy and precision. Its applicability was tested in a case study. Methods: The system, named Spine3D, has the ability to track an infrared beacon equipped with LEDs (IRLED) to reconstruct the pose of each lumbar and thoracic vertebra in 3D space. The system also calculates the spine alignment to the coronal, sagittal and transverse planes. For accuracy and precision evaluation of the system, the beacon was positioned 50 cm away from the IR camera (Wiimote), aligned with in the same plane. The beacon was increasingly translated at 10 mm intervals and rotated at 5°, 10°, 20° and 30° on all three axes. The capture achieved rate was of 100 Hz roughly and accuracy was calculated comparing the results of Spine3D, digital paquimeter and digital inclinometer. Precision was considered as the standard deviation of the collected data. Results: The average accuracy obtained for the system is 0.90° and 0.78 mm, with precision of 0.62° and 0.42 mm. For Cobb angle calculations in coronal plane, accuracy and precision were of 1.46° and 1.72°, and for thoracic kyphosis and lumbar lordosis, the values were 2.82° and 1.60°. During the case study, the difference between the Cobb angle measured by Spine3D and radiography was 1.3° for thoracic scoliosis curve and 2.24° for lumbar scoliosis curve. Conclusion: The Spine3D system offers a non-invasive and radiation-free alternative for three-dimensional spine assessment and representation. Future studies should indicate if the measures taken by the Spine3D system have correlation with the Cobb angle measured by other methods.
236

Avaliação da utilização de um programa computadorizado para aplicação da escala de Basso, Beattie e Bresnahan (BBB) em ratos Wistar / Evaluation of the use of a computer software for the application of the Basso, Beattie e Bresnahan (BBB) scale in Wistar rats

Alessandra Eira Iague Sleiman Molina 31 October 2012 (has links)
A escala de Basso, Beattie e Brenahan (BBB) serve para avaliação da recuperação locomotora em ratos com lesão medular nos níveis torácicos. É baseada em critérios observacionais da movimentação do animal durante a marcha e atribui uma pontuação de 0 a 21 segundo a gravidade da lesão neurológica. Menor pontuação, maior gravidade. Tal escala pode ser aplicada de modo livre, em que o pesquisador observa o rato e emite uma nota; pode ser aplicada de modo dirigido, em que o pesquisador segue uma sequência de perguntas pré-estabelecidas e atribui uma nota; ou de modo automatizado, em que as respostas à mesma sequência de perguntas são fornecidas a um programa de computador, que emitirá uma nota com o grau de lesão. Trabalhos já publicados mostram que existe variação interobservadores na aplicação desta escala. O objetivo do trabalho foi avaliar a utilização de um programa de computador para auxiliar os pesquisadores na atribuição de notas na aplicação da escala BBB e comparar as notas obtidas por esses pesquisadores quando o fazem de modo livre, dirigido e utilizando um programa automatizado. Para testar o programa, foi realizada lesão medular padronizada em 12 ratos Wistar utilizando-se metodologia da New York University - Impactor System. Na sequência, filmou-se a movimentação dos ratos para aplicação da escala BBB no 28o dia. Foram convocados oito pesquisadores do laboratório de estudos de trauma raquimedular da Universidade de São Paulo. As avaliações de dois chefes do laboratório, com 15 anos de experiência na aplicação da escala, foram consideradas o padrão ouro na avaliação. Seis pesquisadores receberam as filmagens dos ratos com o objetivo de aplicar a escala BBB nas três metologias: livre, dirigida e automatizada, com 15 dias de intervalo entre as avaliações. A ordem da aplicação da escala foi randomizada entre os pesquisadores e a ordem dos ratos, nas análises das filmagens, também foi variada para evitar a memorização por parte dos pesquisadores. Os resultados interavaliadores e entre os métodos mostraram-se similares. A comparação dos resultados entre os seis pesquisadores e os dois considerados padrão ouro mostrou diferença para dois pesquisadores nos métodos livre e dirigido. Concluiu-se que a aplicação da escala BBB pelo modo automatizado não apresentou diferença em relação ao padrão ouro para todos os avaliadores, e que, quando feita pelo modo livre, dirigido e automatizado, não apresentou diferença em relação ao padrão ouro, considerando a média dos avaliadores em cada método / The BBB is an evaluation scale in the locomotor recovery in rats presenting thoracic medullar injury. It is based on observation criteria of animal movement while walking, and a provides a score ranging from 0 to 21 according to the severity of the neurological injury. The lower the score, the higher the severity. Such scale can be applied by using a free system of analysis, that is, when the researcher observes the rat and gives a score. The evaluation can also be made in an assisted way, where the researcher follows a series of pre-established questions and then gives a score,or in an automated manner, where the answers to the same sequence of questions are provided to a computer program, which provides a score with the degree of injury. Published research shows that there is a interobserver variation in the scale application The objective of the present study was to evaluate the use of a computer program for helping researchers in the scoring by the BBB scale, and comparing these grades obtained when they are making a free evaluation, in an assisted evaluation and while using a computer program. In order to test the program, a standardized spinal cord injury was performed in 12 Wistar rats in accordance with the methodology proposed by the New York University - Impactor System. Then, the rat movements were filmed on the 28th day, so that the Basso, Bettie and Bresnahan scale could be applied. Eight researchers working in the spinal cord injury laboratory in the University of São Paulo were invited for the study. Two heads of the laboratory, with a fifteen year-experience in the usage and application of the scale, were considered to be gold standard in the evaluation. Six researchers were shown the films and asked to apply the BBB scale by the three methodologies: free, assisted and computerized, with a fifteen-day interval between evaluations. The scale application order was randomized among the researchers as well as the order of the rats in the film analysis so as to avoid memorization on the part of the researchers. Results proved to be similar between researchers and methods. The comparison of results among the six researchers and the gold standard ones showed discrepancies in two of the researchers in the free and assisted methods of analysis. It was concluded that the BBB scale evaluated through the computer method was no different than the gold standard for all the researchers. When the analysis was performed using the free, assisted and computer-assisted methods, no difference was observed in relation to the gold standard considering the mean values in each method
237

Estenose degenerativa do canal lombar = correlação entre o índice de Oswestry e imagem de ressonância magnética = Degenerative lumbar spinal stenosis: correlation with Oswestry index and magnetic ressonance / Degenerative lumbar spinal stenosis : correlation with Oswestry index and magnetic ressonance

Pasqualini, Wagner, 1960- 21 August 2018 (has links)
Orientador: João Batista de Miranda / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-21T06:02:57Z (GMT). No. of bitstreams: 1 Pasqualini_Wagner_D.pdf: 1157517 bytes, checksum: f927ba791a4b318be74e60bad2138135 (MD5) Previous issue date: 2012 / Resumo: Modelo de Estudo: Estudo diagnóstico Transversal de caso controle. Objetivos: comparar pacientes com estenose do canal lombar com indicação de cirurgia e um grupo controle, assintomáticos para esta doença, levando em consideração imagens de ressonância magnética (RM) e o questionário de Oswestry. Material e Método: Vinte e três pacientes com estenose do canal lombar foram comparados com um grupo controle de 17 indivíduos. Todos foram submetidos a RM e responderam ao questionário de Oswestry. Medidas qualitativas foram descritas segundo os grupos com uso de frequências absolutas e relativas e, verificada a existência de associação dessas medidas com uso do teste exato de Fisher. Medidas quantitativas foram descritas e comparadas entre os grupos com uso do teste Mann-Whitney. O teste de Spearman foi utilizado para avaliar a correlação entre os grupos. Resultados: Lombalgia foi a queixa mais frequente nos dois grupos. O índice de Oswestry mostrou média de percentual de invalidez de 45,69% no Grupo Estenose e 11,60% no Grupo Controle. A RM mostrou que a área de secção transversa do saco dural, o diâmetro do canal e a avaliação dos forames e recesso lateral estavam alterados em ambos os grupos. Conclusões: Não houve relação entre o grau de estenose do canal lombar mensurado em exame de RM com o índice de Oswestry em ambos os grupos / Abstract: Study design: Transversal Case-control, diagnostic study. Objectives: To verify the relationship between the degree of lumbar spinal canal stenosis (LCS), as seen in magnetic resonance imaging (MRI), and the severity of disability as seen in the Oswestry Index, in patients with LCS compared to controls without a diagnosed LCS. Methods: Twenty-three patients with a previous diagnosis of LCS were compared with a control group of 17 volunteers. All participants underwent MRI and answered the Oswestry questionnaire. Qualitative data were described according to the groups with the use of absolute and relative frequencies, and the association of these measures was checked by using the Fisher exact test. Quantitative measures were described and compared between groups using the Mann-Whitney test. Spearman's test was used as well. Results: Low back pain was the most frequent complaint in both groups. The Oswestry index showed average percentage of disability of 45.69% in patients with stenosis and 11.60% in the control group. MRI revealed that the dural sac cross-sectional area (DCSA), the diameter of the canal and the evaluation of lateral recesses and foramina were equally changed in both groups. Conclusions: There was no correlation between the degree of lumbar canal stenosis measured on MRI with the Oswestry Disability Index in both groups / Doutorado / Cirurgia / Doutor em Cirurgia
238

Avaliação radiográfica do balanço sagital da coluna vertebral em paraplégicos = um novo paradigma para reabilitação com estimulação elétrica funcional / Sagittal spinal alignment in paraplegics : a new paradigm for the rehabilitation under neuromuscular electrical stimulation

Medeiros, Rodrigo Castro de, 1979- 15 June 2011 (has links)
Orientador: Alberto Cliquet Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-18T12:33:02Z (GMT). No. of bitstreams: 1 Medeiros_RodrigoCastrode_M.pdf: 1107012 bytes, checksum: 8c4a2b98916bf061db40e20d0c7d01a6 (MD5) Previous issue date: 2011 / Resumo: Nas últimas décadas, a reabilitação nos lesado-medulares vem evoluindo através do uso da estimulação elétrica funcional (EEF). Apesar dos inegáveis ganhos cardiovasculares, psicológicos e na densidade mineral óssea advindos desta técnica, o ortostatismo e a deambulação destes pacientes sob estímulo elétrico ainda dependem do suporte fornecido pelos membros superiores. A literatura pertinente aos estudos biomecânicos sobre EEF para ortostatismo em paraplégicos está baseada em teoremas matemáticos fundamentados na física mecânica referente aos braços de alavanca musculoesqueléticos. Contudo, percebe-se uma falha conceitual nestes teoremas a medida que desconsideram os princípios de regulação do reflexo postural observados nos indivíduos sem alterações neurológicas. Nos indivíduos saudáveis, o princípio da conservação de energia exige que, na posição ortostática, a cabeça e tronco estejam alinhados sobre a pelve e centrados em relação aos pés. Para obtenção de uma postura adequada, o organismo utiliza primariamente o reflexo postural espinopélvico, através do qual as curvaturas sagitais da coluna são adaptadas à posição da pelve e dos quadris. O objetivo deste estudo é descrever os aspectos radiográficos do perfil sagital obtidos em pacientes paraplégicos em postura bipedal através da estimulação elétrica funcional dos quadríceps complementados com apoio bimanual. Dez pacientes paraplégicos que participam do ambulatório de reabilitação foram selecionados. Após serem submetidos a radiografias panorâmicas em perfil, foram analisados as médias e os desvios-padrão dos vários parâmetros geométricos descritos na literatura referentes ao equilíbrio sagital em indivíduos saudáveis. Os valores obtidos para cifose torácica e lordose lombar foram semelhantes a dos pacientes saudáveis descritos na literatura. Os parâmetros pélvicos revelaram inversão do tilt pélvico, aumento do slop sacral e diminuição do ângulo sacrofemoral. Nos parâmetros espinopélvicos, foram observados aumentos nas distâncias horizontais entre as vértebras e a bacia e/ou quadris. Estes aspectos traduzem a presença de uma importante anteversão da bacia associada à flexão dos quadris com consequente translação anterior da linha de prumo da coluna expressada através de um intenso desequilíbrio sagital anterior. Para quem deseja optimizara postura bipedal dos paraplégicos sob EEF, este estudo inédito lança uma nova e importante visão sobre a compreensão das alterações ergonômicas presentes no balanço sagital. Tal fato possivelmente servirá de base para o desenvolvimento de novas configurações de EEF / Abstract: In recent decades, the rehabilitation of injured spinal cord-has been evolving through the use of functional electrical stimulation (FES). Despite the undeniable gains cardiovascular, psychological and bone mineral density resulting from this technique, the standing and ambulation of these patients still depend on electrical stimulation of the support provided by the upper limbs. The literature pertaining to the biomechanical studies on FES for standing in paraplegics is based on mathematical theorems based on the physical mechanics related to musculoskeletal lever arms. However, we find a conceptual flaw in these theorems as they disregard the principles of regulation of postural reflex observed in subjects without neurological damage. In healthy subjects, the principle of conservation of energy requires that, in standing position, head and torso are aligned in the pelvis and centered over the feet. To obtain a proper posture, the body uses primarily espinopélvico postural reflex, whereby the sagittal curvatures of the spine are adapted to the position of the pelvis and hips. The aim of this study is to describe the radiographic features of the sagittal profile obtained in bipedal posture in paraplegic patients by functional electrical stimulation of the quadriceps supplemented with bimanual support. Ten paraplegic patients participating in outpatient rehabilitation were selected. After being subjected to panoramic radiography in profile, we analyzed the means and standard deviations of various geometrical parameters described in the literature for the sagittal balance in healthy subjects. The values obtained for thoracic kyphosis and lumbar lordosis were similar to healthy patients in the literature. The parameters revealed pelvic tilt reversal of pelvic, sacral and increase the slop angle reduction sacrofemoral. The spinopelic parameters increases were observed in the horizontal distances in relation to vertebrae and pelvis and/or hips. These aspects reflect the presence of a significant anteversion of the pelvis associated with hip flexion with subsequent anterior translation of the plumb line of the column expressed through an intense anterior sagittal imbalance. For those who want to optimize the bipedal posture of paraplegic patients under FES, this new study sheds new and important insight into the understanding of these ergonomic changes in sagittal balance. This fact possibly serve as the basis for the development of new configurations of FES / Mestrado / Fisiopatologia Cirúrgica / Mestre em Cirurgia
239

Contribuição das forças musculares isocinéticas de joelho e tronco para aquisição da massa óssea em atletas de futebol feminino / Contributions of knee and trunk isokinetic muscular strength to bone mass acquisition in female soccer players

Saccol, Michele Forgiarini 31 October 2007 (has links)
OBJETIVO: Analisar a contribuição da força muscular isocinética de flexores e extensores do joelho dominante e tronco na aquisição da massa óssea das regiões correspondentes a aplicação dessas forças em atletas de futebol feminino (GAF). MÉTODOS: vinte e duas atletas de futebol feminino foram comparadas com 20 controles pareados (GC). O conteúdo mineral ósseo (CMO) e a densidade mineral óssea (DMO) foram avaliados em corpo total, coluna lombar e quadril dominante (fêmur total e colo femoral) pelo software pediátrico do densitômetro Hologic QDR (modelo Discovery, Bedford, MA, USA). Pela análise de corpo total, foram determinadas as variáveis de composição corporal e a massa óssea do membro inferior dominante, tronco e cabeça. A força muscular no movimento de flexão e extensão do joelho e do tronco foi avaliada pelo dinamômetro isocinético Biodex Multi-joint System 3 (Shirley, NY, USA) na velocidade de 60°/s, com 5 repetições do modo concêntrico/excêntrico. As variáveis concêntricas de pico de torque, trabalho na repetição máxima e trabalho total dos flexores e extensores foram considerados. Foram utilizados o teste t de Student para análise entre grupos e os coeficientes de correlação de Pearson e de regressão linear simples para o GAF. RESULTADOS: Os grupos foram semelhantes para idade, peso, altura, raça e ingestão de cálcio (p>0.05), porém o GAF apresentou maior percentual de massa magra e menor percentual de gordura corporal que o GC (p<0.001). Todos os sítios ósseos submetidos à carga mecânica durante o exercício físico apresentaram valores significativamente superiores no GAF, assim como todas as variáveis de força isocinética concêntrica de joelho dominante e tronco (p<0.05 e p<0.001). As variáveis de massa óssea de todas as regiões avaliadas do GAF apresentaram correlações positivas com o peso, índice de massa corporal, massa magra total e do tronco. A DMO das regiões analisadas não apresentou nenhuma correlação significante com as variáveis de força muscular. Porém, todas as variáveis de força de flexão do tronco correlacionaram-se positivamente com o CMO do corpo total e do tronco, assim como as variáveis de extensão do joelho demonstraram associações positivas com o CMO do quadril e do membro inferior dominante. CONCLUSÃO: A força muscular exerceu uma contribuição positiva na aquisição do CMO dos sítios específicos. Esses resultados de correlação positiva entre a força e a quantidade mineral óssea de sítios específicos provêem evidências adicionais de um papel da força muscular na aquisição da massa óssea regional. / OBJECTIVE: to analyze the contribution of isokinetic muscular strength of dominant knee and trunk flexors and extensors in the acquisition of bone mass in the correspondent regions that these forces are applied in female soccer players. METHODS: twenty-two female soccer athletes (GAF) were compared with 20 matched-controls (GC). The bone mineral content (BMC) and bone mineral density (BMD) were evaluated in whole body, lumbar spine and dominant hip (femoral neck and total hip) with the paediatric software of Hologic QDR (Discovery model, Bedford, MA, USA). From whole body scan, the variables of body composition and bone mass of dominant leg, trunk and head were also determined. The muscular strength of flexion and extension movements in dominant knee and trunk were evaluated with the Biodex Multi-joint System 3 (Shirley, NY, USA) with 60°/s, and 5 repetitions at concentric/eccentric mode. The concentric variables peak torque, maximal repetition total work and total work of flexors and extensors were considered. Statistical analysis was performed using Student\'s t-test to compare groups and additionally Pearson\'s correlation coefficient and linear regression analysis to GAF. RESULTS: Both groups were similar regarding age, weight, height, race and calcium intake (p>0.05), however GAF presented a higher percentage of lean body mass and a lower percentage of body fat compared to GC (p<0.001). All loaded sites during exercise had significantly higher values of bone mass for GAF, and so for all isokinetic concentric strength variables of dominant knee and trunk (p<0.05 e p<0.001). Bone mass variables of GAF regions presented positive correlations with weight, body mass index, total and trunk lean mass. The BMD of any region presents significant correlations with variables of strength performance. Nevertheless, all strength variables of trunk flexors were positively correlated with BMC of whole body and trunk, so as knee dominant extensors with BMC of hip and dominant leg. CONCLUSION: muscular strength exerted a positive contribution to BMC acquisition at specifics sites. These results of positive correlation between force and bone mineral quantity of specific sites give us further evidences of the muscle strength role in the acquisition of regional bone mass.
240

Polimorfismos de nucleotídeo único dos genes do sistema OPG/RANKL em mulheres pré-menopausadas com lúpus: associação com massa óssea e fratura vertebral / Single nucleotide polymorphisms of the OPG/RANKL system genes in premenopausal women with SLE: association with bone mass and vertebral fractures

Bonfá, Alessandra Cerezo 25 June 2014 (has links)
Introdução: O aumento da sobrevida dos pacientes com lúpus eritematoso sistêmico (LES) foi acompanhado por um aumento da frequência de comorbidades, tais como osteoporose e fraturas. Há descrições de associação de polimorfismos dos genes receptor ativador do fator nuclear kappa B (RANK), seu ligante (RANKL) e da osteoprotegerina (OPG) com alterações de densidade e fragilidade óssea, entretanto, não há estudos que avaliam estes polimorfismos em pacientes com LES. Objetivos: Avaliar polimorfismos de nucleotídeo único (SNP) dos genes RANKL, OPG e RANK em pacientes pré-menopausadas com LES e sua associação com densidade mineral óssea (DMO), fraturas vertebrais e concentrações séricas de sRANKL e OPG. Métodos: 211 mulheres com LES na pré-menopausa e 154 controles saudáveis foram avaliadas. Os seguintes SNPs foram avaliados por PCR em tempo real: RANKL [290 A > G (rs2277438)], OPG [1181 G > C (rs2073618), 245 T > G (rs3134069), 163 A>G (rs3102735)] e RANK [A > G (rs3018362)]. Concentrações séricas de OPG e sRANKL foram determinadas por ELISA, DMO e fraturas vertebrais por DXA (densitometria de dupla emissão com fonte de raios-X). Resultados: Pacientes e controles apresentaram frequência semelhante do alelo G do gene RANKL 290 A > G (41,2 vs. 40,3%, p=0,91), do alelo C do gene OPG 1181 G >C (62,6 vs. 61,0%, p=0,83), do alelo G da OPG 245 T>G (21,3 vs. 22,7%, p=0,80) do alelo G da OPG 163 A > G (96,2 vs. 87,0%, p=1,00) e do alelo G do RANK A > G (88,2 vs. 96,8%, p=0,75). Quando analisados os pacientes com LES, a frequência dos genótipos associados AG/GG do gene RANKL 290 A>G foi menos frequente em pacientes com fraturas vertebrais que em pacientes sem fraturas (28,1 vs. 46,9%, p=0,01). Com relação à densidade mineral óssea, a frequência dos genótipos associados TG/GG do polimorfismo 245 T > G da OPG foi maior em pacientes com baixa densidade mineral óssea do que em pacientes com densidade mineral óssea normal (31,4 vs. 18,1%, p=0,04). Não houve associação da DMO/fraturas com polimorfismos da OPG 1181 G > C, OPG 163 A > G e RANK A > G. Também não houve associação dos polimorfismos com as concentrações séricas de sRANKL e OPG. Conclusões: O presente trabalho demonstra pela primeira vez que variações genéticas no sistema OPG/RANKL podem desempenhar um papel importante na remodelação óssea e fratura em paciente pré-menopausadas com LES / Introduction: Survival rate improvement in systemic lupus erythematosus was accompanied by an increase in the incidence of long-term bone disorders such as osteoporosis, fractures and osteonecrosis. Polymorphisms of receptor activator of nuclear factor (NF)-kB ligand (RANKL) and osteoprotegerin (OPG) genes are known to influence bone mineral density and structure. However, there are no studies assessing these polymorphisms in SLE patients. Objective: To evaluate receptor activator of nuclear factor-kB (RANK) it ligand (RANKL) and osteoprotegerin (OPG) genes single nucleotide polymorphisms (SNP) in premenopausal SLE patients and their association with sRANKL and OPG serum levels, vertebral fractures and bone mineral density (BMD). Methods: 211 premenopausal SLE patients (ACR criteria) and 154 healthy controls were enrolled. SNPs of RANKL [290 A > G (rs2277438)], OPG [1181G > C (rs2073618), 245T>G (rs3134069), 163 A>G (rs3102735)] and RANK [A > G (rs3018362)] were obtained by real-time PCR. sRANKL/OPG serum levels were determined by ELISA. BMD and vertebral fractures were evaluated by dual energy X-ray absorptiometry. Results: SLE patients and controls had similar frequency of RANKL 290 G allele (41.2 vs. 40.3%, p=0.91), OPG 1181 C allele (62.6 vs. 61.0%, p=0.83), OPG 245 G allele (21.3 vs. 22.7%, p=0.80), OPG 163 G allele (96.2 vs. 87.0%, p=1.00) and RANK G allele (88.2 vs. 96.8%, p=0.75). Further analysis of SLE patients revealed that the frequency of RANKL 290 G allele was lower in patients with fractures than in patients without fractures (28.1 vs. 46.9%, p=0.01). In addition, the frequency of OPG 245 G allele was higher in patients with low BMD than in patients with normal BMD (31.4 vs. 18.1%, p=0.04). No association of OPG 1181 G > C, OPG 163 A > G and RANK A > G SNPs with BMD/fractures were found. Also, no association was observed between RANKL/OPG/RANK SNPs and sRANKL/OPG serum levels. Conclusions. Our study provides novel data demonstrating that RANKL/OPG genetic variations seem to play a role in bone remodeling and particularly in its main complication, fracture, in premenopausal patients with SLE

Page generated in 0.0883 seconds