Spelling suggestions: "subject:"contaminantes."" "subject:"ontaminantes.""
71 |
Formación de contaminantes y estudio cinético de la descomposición térmica de dos combustibles alternativos: CDR y ASRRey Martínez, Lorena 11 July 2016 (has links)
No description available.
|
72 |
Estudios de identificación y caracterización de agentes contaminantes virales en colonias de cría de ratonesMaiza, Andrea Soledad 03 March 2013 (has links)
Se conoce ampliamente que la confiabilidad de una colonia de cría de
ratones para un determinado experimento puede ser solamente demostrada
mediante un comprensivo monitoreo del estado de salud de los animales antes
y durante el experimento. En este trabajo se han desarrollado las técnicas de
inmunofluorescencia indirecta (IFI) y enzimoinmunoensayo (ELISA) para la
detección de anticuerpos contra el virus Sendai, virus de la hepatitis murina y el
virus diminuto o minuto de ratón en las colonias de cría del ratón, considerados
los agentes virales más prevalentes en las colonias SPF de ratones. Se estudió
la cinética de replicación para cada virus mediante la cosecha de células y
sobrenadantes respectivos, en diferentes días post inoculación (pi).Se obtuvo
una Semilla Maestra y una Semilla de Trabajo para el virus Sendai mediante la
inoculación del virus en huevos embrionados de pollo. La Semilla de Trabajo
sin diluir y en diluciones factor de 10 se utilizó para inmunizar a los ratones con
diferentes esquemas de inoculación. Los sueros y líquidos ascíticos
presentaron títulos de anticuerpos específicos entre 64 y 256, por la inhibición
de hemaglutinación (HAI) y IFI, mientras que los títulos por ELISA estuvieron
entre 6400 y 204800, para las mismas muestras. Para el virus MHV la Semilla
Maestra y la Semilla de Trabajo se obtuvo por inoculación del virus en
monocapas de células L929. Diluciones factor 10 de la cepa viral MHV se
utilizó para inmunizar a los ratones con diferentes esquemas de inoculación.
Los sueros y líquidos ascíticos presentaron títulos de anticuerpos específicos
entre 32 y 2048 por IFI, mientras que los títulos por ELISA estuvieron entre
3200 y 12800 para los sueros y entre 200 y 6400 para los líquidos ascíticos,
para las mismas muestras. Para el virus MVM la Semilla Maestra y la Semilla
de Trabajo se obtuvo por inoculación del virus en monocapas de células L929.
Diluciones factor 10 de la cepa viral MVM y de la ST viral se utilizó para
inmunizar a los ratones con diferentes esquemas de inoculación. Los sueros y
líquidos ascíticos se presentaron títulos de anticuerpos específicos entre 32 y
128 por inmunofluorescencia indirecta (IFI), mientras que los títulos por ELISA
estuvieron entre 1600 y 6400 para los sueros y entre 200 y 800 para los
líquidos ascíticos, para las mismas muestras. El antígeno para la pruebas IFI consistió en células enteras, mientras que para las pruebas de ELISA fue células lisadas por sonicación. Para el virus
Sendai ambos antígenos se obtuvieron por inoculación de 0,1 UHA de la ST en
células LLCMK2 y se cosechó el día 7pi. Para el virus MHV se inoculó ~105
DICT 50 / mL y para el virus MVM ~10 6DICT 50 / mL, en células L929. Las
células fueron procesadas el día 5 y 1 pi respectivamente. Nuestros estudios
muestran que el desarrollo de las pruebas de IFI y ELISA, (complementadas
con la prueba clásica de HAI para el caso del virus Sendai), comprenden una
batería de pruebas innovadoras y confiables para la detección de anticuerpos
contra los virus de Sendai, MHV y MVM en bioteros. Los resultados
presentados revelan que las metodologías desarrolladas en nuestro laboratorio
son herramientas eficaces para el control de la contaminación por los agentes
virales estudiados en colonias de ratones libres de patógenos específicos. Los
estudios presentados podrían considerarse como un punto de partida para el
desarrollo de futuros avances en este campo del conocimiento.
Palabras claves: ratones SPF, virus contaminantes de roedores , enzimo
inmuno análisis (ELISA), inmunofluorescencia indirecta (IFI) / It is widely known that the reliability of a mouse breeding colony for a
given experiment only can be demonstrated by a comprehensive health
monitoring of the animals before and during the experiment. We recommend
finding specific antibodies as indicators of virus circulation in the colony. In this
work, we developed the techniques of indirect immunofluorescence (IFI) and
enzyme immunoassay (ELISA) for the detection of antibodies to Sendai virus,
MHV virus and MVM virus in mouse breeding colonies. It was studied the
kinetics for each virus replication by harvesting cells and its respective
supernatants at different days post inoculation (pi). It was generated both a
master sample and a working sample by inoculation of Sendai virus in
embryonated chicken eggs. The working sample undiluted and 10-fold serial
dilutions were used to immunize mice following different schemes of inoculation.
Serum and ascitic fluid samples were collected and showed titers of specific
antibodies between 64 and 256, by hemaglutination inhibition (HAI) and IFI,
whereas serum and ascitic fluid samples showed titers between 6400 and
204800, by ELISA. The master sample for MHV virus and Working sample was
obtained by inoculation of the virus in L929 cell monolayers. The MHV virus 10-
fold serial dilutions were used to immunize mice following different schemes of
inoculation. Serum and ascitic fluids samples were collected and specific
antibody titers between 32 and 2048 by IFI, while ELISA titers were between
3200 and 12800 for the serum and 200 to 6400 for ascitic fluids samples, for the
same samples. The master sample for MVM virus and Working sample was
obtained by inoculation of the virus in L929 cell monolayers. The working
sample and 10-fold serial dilutions of MVM virus were used to immunize mice
following different schemes of inoculation.Serum and ascitic fluids samples
were collected and specific antibody titers between 32 and 128 by indirect IFI,
while ELISA titers were between 1600 and 6400 for serum and 200 to 800 for
ascites fluids samples, for same samples. The antigen for IFA tests consisted of
whole cells, while for the ELISA was lysed cells by sonication. Sendai virus for
both antigens was obtained on day 7pi in LLCMK2 cells by inoculation of 0.1
UHA of working sample. For MVM virus was inoculated ~10 6DICT 50 / mL and
MHV was inoculated ~105 DICT 50 / mL. They were processed L929 cells and
used on day 1 and 5pi respectively. Our results show that the development of
specific IFI and ELISA, (complemented by the classical test of HAI for Sendai
virus), comprise a battery of innovative and reliable tests for the detection of
antibodies against Sendai virus, MHV virus and MVM virus in laboratory mice.
These initial data reveal that both tests might be efficient tools for the monitoring
of contamination by these viral agents in colonies of specific pathogen free
mice. The studies presented could be considered as a starting point for the
development of future advances in this field of knowledge.
Keywords: specific pathogen free mice, rodent virus contaminantion, enzyme
immunoassay (ELISA), immunoflurescence assay (IFI)
|
73 |
[en] AN ASSESSMENT OF THE USE OF PROCESSED OIL GROUND AS LIVER MATERIAL OF LANDFILLS / [pt] AVALIAÇÃO DO USO DE BORRA OLEOSA PROCESSADA EM SISTEMAS DE IMPERMEABILIZAÇÃO DE ATERROSSIMONE HARTH OLIVEIRA 09 September 2002 (has links)
[pt] Este trabalho tem como objetivo apresentar uma avaliação do uso de borra oleosa processada como material de
construção em sistemas de impermeabilização de Aterros Sanitários. O estudo se baseia em resultados de ensaios de laboratório
e em dados fornecidos pela PETROBRAS, além de informações da literatura, as quais foram utilizadas para prever a
mobilidade do contaminante e os principais mecanismos de interação entre este e a borra. Foi desenvolvido um
equipamento para a realização de ensaios de transporte em laboratório, que permite a determinação dos parâmetros de
transporte do contaminante no solo. / [en] The purpose of this thesis is to present an evaluation of
the use o processed oil ground as a building material for
barrier systems in Landfill facylities. The study is based
on experimental laboratory results and on PETROBRAS data,
besides literature data, which have been used for
predicting the contaminant mobility and the main mechanisms
of its interaction with the soil.An equipment has been
developed to carry out laboratory tests on confined soil
samples using water and a contaminant solution as the
percolating fluid, which allows the determination of the
transport parameters of the contaminant in the soil.
|
74 |
El delito de propagación indebida de contaminantes del artículo 291 del Código PenalOlea Jaqueih, Catalina January 2017 (has links)
Memoria de Prueba para optar al Grado de Licenciado en Ciencias Jurídicas y Sociales / La presente memoria tiene por objeto profundizar el estudio del delito contemplado en el artículo 291 del Código Penal, el cual ha cobrado vital importancia por la creciente conciencia de repulsa al daño ambiental y hoy carente de un prolífero análisis dogmático.
En específico, ahondar en el origen de la norma, la necesidad de legislar acerca de la propagación de contaminantes, y el desarrollo que el proyecto de ley tuvo en su tramitación; analizar los elementos de la tipicidad que contempla el delito, a saber, su bien jurídico protegido, sujetos activo y pasivo, la conducta, objeto material de la conducta, elementos normativos del tipo y la causalidad; analizar las distintas formas de aparición del delito, en tanto a su autoría y participación, iter críminis, concurso de delitos, culpabilidad, causales de justificación y de exculpación, penalidad y extinción de la responsabilidad penal; finalmente analizar la aplicación del delito y establecer los problemas que se presentan para la misma, basándonos en estadísticas y jurisprudencia.
La metodología utilizada será la propia de las ciencias jurídicas, a saber, el método dogmático.
|
75 |
Avaliação da qualidade do ar em duas estações do metrô de São Paulo / Air quality evaluation in two stations of the São Paulo SubwayFujii, Reinaldo Keiji 14 September 2006 (has links)
Objetivo. Comparar a qualidade do ar externo com o ambiente interno das estações Clínicas e Praça da Sé do Metrô de São Paulo, quantificando e qualificando os contaminantes microbiológicos e atmosféricos. Propõe-se com este estudo promover o conhecimento de fatores sobre a qualidade do ar e das condições de higiene e saúde destes locais, contribuindo para a melhoria da qualidade de vida dos trabalhadores e usuários do sistema. Métodos. As amostras foram realizadas no período de Julho a Novembro de 2005. Os fungos foram coletados com o impactador de Andersen de um estágio com volume de aspiração de 28 l/min por um tempo de 10 minutos por amostra, e como meio de cultivo Agar Sabouraud Dextrose a 4 por cento . A quantificação e identificação foram feitas por meio de análises de lâminas do material microbiológico em microscópio óptico, coradas com azul de lactofenol. Para o dióxido de nitrogênio utilizou-se difusor passivo com trietanolamina como substância adsorvente e as análises foram realizadas por espectrofotometria. O difusor passivo para avaliação da concentração de benzeno é do tipo membrana, com carvão ativado como substância adsorvente e a análise por cromatografia gasosa. O tempo de exposição para estes amostradores foi de 30 dias. O PM10 foi medido com um monitor contínuo, com leitura direta. Foram instalados dois equipamentos em cada estação por um período de 7 dias. Resultados. Os estudos indicam a presença de fungos comuns com predominância para o Cladosporium sp (52 por cento ), Alternaria sp (17 por cento ) e Penicillium sp (13 por cento ) e em proporções semelhantes interna e externamente às estações. A concentração média de NO2 no interior das estações, foi de 73,9JPñ (VWHV YDORUHV Vão semelhantes às medições externas realizadas com o equipamento de Espectroscópia de Absorção por Diferencial Óptico (DOAS) e os valores medidos pela estação de monitoramento da CETESB, instalado na FSP/USP. Os valores viii máximos encontrados para o benzeno foram de 5,7JPñ QR LQWHULRU GDV estações e 6,2JPñQRDPELHQWHH[WHUQR230LQGLFRXYDORUHVHOHYDGRV sendo o valor médio, para a estação Clínicas de 312,4JPñ PHGLGRV QD SODWDIRUPDHJ/m³ no mezanino, na estação Praça da Sé verificamos a concentração de 150,9JPñ QD SODWDIRUPD GD OLQKD H JPñ QD plataforma da linha 3. Conclusões. O presente estudo possibilitou a avaliação e comparação dos níveis de poluição ambiental interno e externo às estações. A constatação da predominância de fungos comuns no ar não indica a ausência de riscos para a saúde humana, pois o seu impacto depende da suscetibilidade dos indivíduos expostos. A concentração de NO2 e benzeno encontradas no ambiente interno e externo são de mesma ordem de grandeza, o que indica que estes contaminantes têm a mesma fonte de origem. A alta concentração de PM10 representa uma maior preocupação. Para este contaminante deve-se avaliar a composição do material encontrado e seu grau de toxicidade / Objective. Compare the air quality outdoors with the indoors environment at Clínicas and Praça da Sé Stations of the São Paulo Subway, measuring the quantity and quality of the existing microbiological and atmospheric contaminants. The purpose of this study is to promote the knowledge of factors related to the air quality and the health and hygiene conditions in these places, contributing to the improvement of the quality of life of employees and users of the system. Methods. The samples were taken from July to November 2005. The fungi were taken by one-stage Andersen impactor with aspiration volume of 28 l/min for a period of 10 minutes per sample, making use of Agar Sabouraud Dextrose at 4 per cent for the culture. The quantification and identification are done by the analysis of slides with the microbiological material in an optical microscope, colored with lactofenol blue. For the nitrogen dioxide, a passive diffuser was used with triethanolamine as absorbing substance and the analysis was done by spectrophotometry, the passive diffuser used to evaluate the concentration of benzene is the membrane type with activated carbon as absorbing substance making use of gas chromatography analysis. The exposure period for these samplers was 30 days. The PM10 was measured with a continuous monitor, with direct reading. This equipment uses fibreoptic sensors for the identification of the size and concentration of the particles which are sucked by a diaphragm pump, passing through a measuring chamber which also measures the temperature and the air humidity. Two pieces of this equipment were installed in each station for a period of seven days. Results. The studies indicate the presence of ordinary fungi with the prevalence of Cladosporium sp (52 per cent ), Alternaria sp (17 per cent ) and Penicillium sp (13 per cent ) in similar proportions both indoors and outdoors. The indoor average concentration of NO2 was 69,5g/m³. These values are similar to the outdoor x results obtained with the equipment for Differential Optical Absorption Spectroscopy (DOAS) and the values measured by CETESB control station, located at FSP/USP. The values found for benzene ranged from 3,8 to 6,2g/m³, indicating an average of 5,0g/m³. The PM10 indicated high values with an average, at Clínicas Station, of 312,4 g/m³ measured in the platform and 243,9 g/m³ in the mezzanine. At Praça da Sé Station the concentration on the platforms was 150,9 g/m³ for line 1 and 124,2 g/m³ for line 3. Conclusions. The present study permitted the assessment and comparison of the environmental pollution levels inside and outside the stations. The verification of the predominance of common fungi in the air doesn\'t indicate the absence of risks for the human health, because it impact depends on the exposed individuals\' susceptibility. The concentration of NO2 and benzene found in the internal and external atmosphere are of same order of greatness, what indicates that these pollutants have the same origin source. The high concentration of PM10 represents a larger concern. This pollutant it should be evaluated the composition of the found material and his toxicity degree
|
76 |
Contaminantes orgânicos em monômero cloreto de vinila (MVC): desenvolvimento de método para identificação por TD-GC-MS e análise por PCA aplicada a amostras de diferentes pontos de um processo industrialSantos, Fábio Neves dos 02 1900 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2014-09-17T15:13:51Z
No. of bitstreams: 1
Fabio Neves Dissertação.pdf: 1617814 bytes, checksum: 880cf6fc37213ab6dcd60cf882b1ffb3 (MD5) / Approved for entry into archive by Fatima Cleômenis Botelho Maria (botelho@ufba.br) on 2014-09-19T12:31:43Z (GMT) No. of bitstreams: 1
Fabio Neves Dissertação.pdf: 1617814 bytes, checksum: 880cf6fc37213ab6dcd60cf882b1ffb3 (MD5) / Made available in DSpace on 2014-09-19T12:31:43Z (GMT). No. of bitstreams: 1
Fabio Neves Dissertação.pdf: 1617814 bytes, checksum: 880cf6fc37213ab6dcd60cf882b1ffb3 (MD5) / O monômero cloreto de vinila (MVC) é a principal matéria-prima utilizada na
produção do Policloreto de vinila (PVC). Sendo assim, o controle da pureza do
MVC é fundamental para o controle da reação de polimerização, bem como para
as propriedades do PVC, visto que alguns contaminantes orgânicos reagem como
co-monômeros. Portanto, faz-se necessário o desenvolvimento de metodologias
para identificação das substâncias presentes como contaminantes do MVC. Neste
trabalho, foram desenvolvidos métodos de identificação dos contaminantes,
baseados na sua pré-concentração por adsorção em Tenax-TA e Tenax-
TA/Carboxen1000/CarbosieveSIII, seguidos de dessorção térmica e análise por
cromatografia gasosa acoplada à espectrometria de massas (TD-GC-MS). A
otimização desses métodos foi realizada utilizando-se planejamento fatorial de
experimentos completo e fracionário. Os métodos otimizados foram utilizados na
identificação dos contaminantes do MVC nas etapas do processo de obtenção,
armazenamento e recuperação do monômero, correspondendo a quatro pontos
distintos de coleta das amostras. Foram identificadas ao todo dezenove
substâncias
dentre
as
quais
hidrocarbonetos alifáticos
e
aromáticos,
organoclorados, alcoóis, fenóis e fenonas. Destas, doze estavam presentes no
MVC virgem, treze no MVC da esfera de armazenamento, doze no MVC da
entrada dos reatores de polimerização e dezesseis no MVC recuperado. Os
contaminantes presentes com as maiores concentrações relativas nos diferentes
pontos foram estireno, aromático C6, tolueno, naftaleno, 1-octanol e 1,3-
butadieno. Destes, estireno e 1,3-butadieno tem sido relatados na literatura como
sendo fortes inibidores de polimerização para o MVC. Através da análise de
componentes principais foi possível comprovar que há diferenças nas
características do MVC, a depender do ponto do processo de onde ele é captado.
Além disso, foi possível classificar as amostras de MVC, provenientes de
diferentes pontos do processo, em três agrupamentos distintos, bem como
identificar em cada agrupamento os principais contaminantes responsáveis pelas
diferenciações. Considerando que o controle da pureza do monômero é
fundamental para a qualidade do PVC, estes resultados demonstram a
importância de realizar experimentos em escala de laboratório com o MVC
proveniente de cada ponto, a fim de verificar a influência dos seus contaminantes
característicos sobre as propriedades do PVC produzido. Com essas informações
será possível buscar estratégias para a eliminação ou redução dos principais
contaminantes responsáveis pelas alterações nas propriedades do produto final. / The Vinyl Chloride Monomer (MVC) is the main raw material used in the
production of Poly (Vinyl Chloride) (PVC). Thus, the control of MVC purity is
essential to control polymerization reaction, as well as the properties of PVC, since
some organic contaminants react as co-monomers. Therefore, it is necessary to
develop methodologies for the identification of substances as contaminants MVC. In
this work, we developed methods for identifying contaminants, based on your pre-
concentration
by
adsorption
on
Tenax-TA
and
Tenax-
TA/Carboxen1000/CarbosieveSIII, followed by thermal desorption and analysis by
Gas Chromatography-Mass Spectrometry (TD-GC-MS). The optimization of these
methods was performed using full factorial design of experiments and fractional. The
optimized methods were used in the identification of contaminants in the MVC
stages of acquisition, storage and retrieval of the monomer, corresponding to four
distinct points of sample collection. We identified a total of nineteen substances
among which aliphatic and aromatic hydrocarbons, organochlorine, alcohols,
phenols and fenonas. Of these, twelve were present in virgin MVC, MVC thirteen in
the storage sphere, twelve in MVC input of polymerization reactors and sixteen in
MVC recovered. Contaminants with higher relative concentrations in different points
were styrene, benzene, toluene, naphthalene, 1-octanol and 1,3-butadiene. Of
these, 1,3-butadiene and styrene have been reported in the literature as strong
polymerization inhibitors for MVC. Through Principal Component Analysis was
possible to prove that there are differences in the characteristics of the MVC,
depending on the point in the process where it is captured. Moreover, it was possible
to classify the samples MVC from different points of the process in three distinct
clusters and identify each cluster major contaminants responsible for differentiation.
Whereas the control of the purity of the monomer is critical to the quality of the PVC,
these results demonstrate the importance of conducting experiments on a laboratory
scale with the MVC from each point, in order to check the influence of its
contaminants on the characteristic properties of PVC produced. With this information
you can find strategies for elimination or reduction of major pollutants responsible for
changes in the properties of the final product.
|
77 |
Avaliação da qualidade do ar em duas estações do metrô de São Paulo / Air quality evaluation in two stations of the São Paulo SubwayReinaldo Keiji Fujii 14 September 2006 (has links)
Objetivo. Comparar a qualidade do ar externo com o ambiente interno das estações Clínicas e Praça da Sé do Metrô de São Paulo, quantificando e qualificando os contaminantes microbiológicos e atmosféricos. Propõe-se com este estudo promover o conhecimento de fatores sobre a qualidade do ar e das condições de higiene e saúde destes locais, contribuindo para a melhoria da qualidade de vida dos trabalhadores e usuários do sistema. Métodos. As amostras foram realizadas no período de Julho a Novembro de 2005. Os fungos foram coletados com o impactador de Andersen de um estágio com volume de aspiração de 28 l/min por um tempo de 10 minutos por amostra, e como meio de cultivo Agar Sabouraud Dextrose a 4 por cento . A quantificação e identificação foram feitas por meio de análises de lâminas do material microbiológico em microscópio óptico, coradas com azul de lactofenol. Para o dióxido de nitrogênio utilizou-se difusor passivo com trietanolamina como substância adsorvente e as análises foram realizadas por espectrofotometria. O difusor passivo para avaliação da concentração de benzeno é do tipo membrana, com carvão ativado como substância adsorvente e a análise por cromatografia gasosa. O tempo de exposição para estes amostradores foi de 30 dias. O PM10 foi medido com um monitor contínuo, com leitura direta. Foram instalados dois equipamentos em cada estação por um período de 7 dias. Resultados. Os estudos indicam a presença de fungos comuns com predominância para o Cladosporium sp (52 por cento ), Alternaria sp (17 por cento ) e Penicillium sp (13 por cento ) e em proporções semelhantes interna e externamente às estações. A concentração média de NO2 no interior das estações, foi de 73,9JPñ (VWHV YDORUHV Vão semelhantes às medições externas realizadas com o equipamento de Espectroscópia de Absorção por Diferencial Óptico (DOAS) e os valores medidos pela estação de monitoramento da CETESB, instalado na FSP/USP. Os valores viii máximos encontrados para o benzeno foram de 5,7JPñ QR LQWHULRU GDV estações e 6,2JPñQRDPELHQWHH[WHUQR230LQGLFRXYDORUHVHOHYDGRV sendo o valor médio, para a estação Clínicas de 312,4JPñ PHGLGRV QD SODWDIRUPDHJ/m³ no mezanino, na estação Praça da Sé verificamos a concentração de 150,9JPñ QD SODWDIRUPD GD OLQKD H JPñ QD plataforma da linha 3. Conclusões. O presente estudo possibilitou a avaliação e comparação dos níveis de poluição ambiental interno e externo às estações. A constatação da predominância de fungos comuns no ar não indica a ausência de riscos para a saúde humana, pois o seu impacto depende da suscetibilidade dos indivíduos expostos. A concentração de NO2 e benzeno encontradas no ambiente interno e externo são de mesma ordem de grandeza, o que indica que estes contaminantes têm a mesma fonte de origem. A alta concentração de PM10 representa uma maior preocupação. Para este contaminante deve-se avaliar a composição do material encontrado e seu grau de toxicidade / Objective. Compare the air quality outdoors with the indoors environment at Clínicas and Praça da Sé Stations of the São Paulo Subway, measuring the quantity and quality of the existing microbiological and atmospheric contaminants. The purpose of this study is to promote the knowledge of factors related to the air quality and the health and hygiene conditions in these places, contributing to the improvement of the quality of life of employees and users of the system. Methods. The samples were taken from July to November 2005. The fungi were taken by one-stage Andersen impactor with aspiration volume of 28 l/min for a period of 10 minutes per sample, making use of Agar Sabouraud Dextrose at 4 per cent for the culture. The quantification and identification are done by the analysis of slides with the microbiological material in an optical microscope, colored with lactofenol blue. For the nitrogen dioxide, a passive diffuser was used with triethanolamine as absorbing substance and the analysis was done by spectrophotometry, the passive diffuser used to evaluate the concentration of benzene is the membrane type with activated carbon as absorbing substance making use of gas chromatography analysis. The exposure period for these samplers was 30 days. The PM10 was measured with a continuous monitor, with direct reading. This equipment uses fibreoptic sensors for the identification of the size and concentration of the particles which are sucked by a diaphragm pump, passing through a measuring chamber which also measures the temperature and the air humidity. Two pieces of this equipment were installed in each station for a period of seven days. Results. The studies indicate the presence of ordinary fungi with the prevalence of Cladosporium sp (52 per cent ), Alternaria sp (17 per cent ) and Penicillium sp (13 per cent ) in similar proportions both indoors and outdoors. The indoor average concentration of NO2 was 69,5g/m³. These values are similar to the outdoor x results obtained with the equipment for Differential Optical Absorption Spectroscopy (DOAS) and the values measured by CETESB control station, located at FSP/USP. The values found for benzene ranged from 3,8 to 6,2g/m³, indicating an average of 5,0g/m³. The PM10 indicated high values with an average, at Clínicas Station, of 312,4 g/m³ measured in the platform and 243,9 g/m³ in the mezzanine. At Praça da Sé Station the concentration on the platforms was 150,9 g/m³ for line 1 and 124,2 g/m³ for line 3. Conclusions. The present study permitted the assessment and comparison of the environmental pollution levels inside and outside the stations. The verification of the predominance of common fungi in the air doesn\'t indicate the absence of risks for the human health, because it impact depends on the exposed individuals\' susceptibility. The concentration of NO2 and benzene found in the internal and external atmosphere are of same order of greatness, what indicates that these pollutants have the same origin source. The high concentration of PM10 represents a larger concern. This pollutant it should be evaluated the composition of the found material and his toxicity degree
|
78 |
Aplicació de tècniques ecotoxicològiques en diferents matrius ambientals. Viabilitat i complementarietatRoig Montserrat, Neus 23 November 2012 (has links)
L’objectiu general d’aquesta tesi ha estat avaluar l’aplicabilitat de bioassajos específics i un bioassaig estandarditzat genèric en mostres de diferents matrius ambientals. D’aquesta manera es pretén complementar la informació obtinguda de les anàlisis químiques per tal de poder establir un millor diagnòstic ambiental. S’han analitzat diferents metalls i compostos orgànics en mostres dels diferents compartiments ambientals. Per avaluar l’ecotoxicitat de mostres d’aigua dolça, s’ha triat l’alga Pseudokirschneriella subcapitata, mentre que per mostres de sòl i residus orgànics, s’han escollit plantes d’interès agrícola com són Allium cepa, Raphanus sativus i Lolium perenne. Per últim, s’han realitzat tests in vitro de toxicitat humana per avaluar la toxicitat de les partícules PM10 de l’aire amb cultius de cèl•lules pulmonars (línia A549). En tots els casos, s’ha realitzat també un assaig ecotoxicològic amb el bacteri luminescent Vibrio fischeri, per avaluar la seva idoneïtat en les diferents matrius ambientals. Els resultats, han demostrat que l’aplicació de bioassajos específics en diferents matrius ambientals pot suposar una bona eina d’“screening” per completar la informació obtinguda de les anàlisis químiques que, realitzades de forma individual, poden estimar erròniament la toxicitat real de les mostres ambientals. S’ha observat que el bioassaig amb Vibrio fischeri ha mostrat bona complementarietat amb d’altres assajos més específics de cada matriu, a més de resultar molt sensible a la presència de contaminants en aigües i sediments fluvials, fangs de depuradora i partícules d’aire PM10. / El objetivo general de esta tesis ha sido evaluar la aplicación de bioensayos específicos y un bioensayo estandardizado genérico en distintas matrices ambientales. De este modo se pretende complementar la información obtenida con los análisis químicos para poder establecer un mejor diagnóstico ambiental. Se han analizado metales y compuestos orgánicos en muestras de distintos compartimentos ambientales. Para evaluar la ecotoxicidad de muestras de agua dulce se ha escogido el alga Pseudokirschneriella subcapitata, mientras que para muestras de suelos y residuos orgánicos se han escogido plantas de interés agrícola como son Allium cepa, Raphanus sativus y Lolium perenne. Por último, se han realizado tests in Vitro de toxicidad humana para evaluar la toxicidad de las partículas PM10 del aire, con cultivos de células pulmonares (línea A549). En todos los casos se ha realizado un ensayo ecotoxicológico con la bacteria luminescente Vibrio fischeri, para evaluar su idoneidad en las distintas matrices ambientales. Los resultados han demostrado que el uso de bioensayos específicos en distintas matrices ambientales puede suponer una buena herramienta de ‘’screening’’ para completar la información obtenida de los análisis químicos, que realizados de forma individual, pueden estimar erróneamente la toxicidad real de las muestras ambientales. Además, se ha observado que el bioensayo con Vibrio fischeri presenta buena complementariedad con otros ensayos más específicos de cada matriz ambiental, además de ser muy sensible a la presencia de contaminantes en aguas y sedimentos fluviales, lodos de depuradora y PM10 del aire.
|
79 |
Efeito tóxico da cafeína sobre o ciclo de vida de Chironomus sancticaroli (Chironomidae, Diptera) e Daphnia magna (Daphniidae, Cladocera) / Caffeine toxic effect on Chironomus sancticaroli (Diptera: Chironomidae) life cycle and Daphnia magna (Cladocera: Daphnidae)Bernegossi, Aline Christine 02 April 2019 (has links)
A cafeína está presente no cotidiano humano desde o tradicional café até como constituinte de medicamentos, estimulantes, chás, chocolate entre outros produtos alimentícios. Essa substância é considerada um contaminante orgânico emergente provindo de águas residuárias não tratadas. Sua presença nos corpos hídricos vem sendo documentada em baixas concentrações, desde ηg.L-1 até µg.L-1 e os efeitos dessas concentrações nos organismos aquáticos ainda não foram efetivamente investigados. Com o objetivo de avaliar os efeitos tóxicos da cafeína em concentrações comumentemente encontradas em corpos hídricos, foram realizados testes de ecotoxicidade aguda e crônica com os organismos-teste Chironomus sancticaroli e Daphnia magna e intergeracional com C. sancticaroli, com enfoque em respostas biológicas de mortalidade, imobilidade, crescimento, desenvolvimento e reprodução. Como resultado, a cafeína não apresentou toxicidade aguda no teste de curta duração realizado para D. magna e C. sancticaroli. Foi observado efeito de toxicidade crônica da cafeína, havendo interferência no desenvolvimento das larvas de Chironomus principalmente na concentração de 200 µg.L-1 e no crescimento e reprodução de D. magna, na qual foi observada indução na produção de neonatos e desaceleração para o desenvolvimento do organismo (retardo no processo de ecdise). No teste intergeracional, foram observadas mudanças nos padrões de desenvolvimento larval. Os resultados demonstram que a cafeína, em concentrações ambientalmente detectadas, pode causar pequenas alterações no ciclo de vida dos organismos, como por exemplo, alterações no tamanho das asas das fêmeas e no comprimento do corpo das larvas de C. sancticaroli. Recomendam-se o uso de técnicas biomoleculares para avaliar as respostas metabólicas dos organismos quando exposto à cafeína em baixas concentrações. / Caffeine is present in human daily life either as traditional coffee or constituent of medicines, stimulants, teas, chocolate, among other products. This substance is an emerging organic contaminant from untreated wastewater. Its presence in aquatic systems has been documented at low concentrations, from ηg.L-1 to µg.L-1 and the effects of these concentrations on aquatic organisms have not yet been effectively investigated. In order to evaluate the toxic effects of caffeine, at concentrations usually found in aquatic systems, acute and chronic ecotoxicological tests were performed with Chironomus sancticaroli and Daphnia magna and, an intergenerational with C. sancticaroli, focusing on biological responses of mortality, immobility, growth, development and reproduction. As a result, caffeine did not present acute toxicity in the shor-term test performed for D. magna and C. sancticaroli. Chronic toxicity of caffeine was observed, with interference in the Chironomus larvae development, mainly in the concentration of 200 µg.L-1, and in the growth and reproduction of D. magna, in which it was observed presence of induction in the production of neonates and deceleration to the development of the organism (delay in the process of ecdysis). In intergeneration test, changes in the larval developmental patterns were observed. In intergenerational testing, changes in larval developmental patterns were observed. The results demonstrate that caffeine, in concentrations detected environmentally, can cause small influences in the organism\'s life cycle of the, for example, changes in the size of the wings of the females and in the length of the body of the larvae of C. sancticaroli. The use of biomolecular techniques to evaluate the metabolic responses of organisms when exposed to caffeine at low concentrations is recommended.
|
80 |
Cinética de adsorção de Pb e Cd em solo argiloso laterítico. / Adsorption kinetic of Ph and Cd in a lateritic soil.Jiménez Vega, Bernardo José 24 October 2016 (has links)
A adsorção de metais em solos tem sido estudada no escopo da geotecnia ambiental principalmente para prever formação de plumas, estudar viabilidade de técnicas de remediação e projetar revestimentos impermeabilizantes em sistemas de disposição de resíduos, entre outros. A consideração da adsorção como um fenômeno imediato e reversível é geralmente aceitável nessas aplicações, porém tem-se verificado que para solos tropicais o estudo da cinética pode melhorar as retroanálises de dados de campo e as interpretações de resultados experimentais. Este trabalho apresenta aspectos teóricos da cinética de adsorção, incluindo fatores que afetam a cinética de adsorção, modelos para determinar os mecanismos que controlam a cinética de adsorção e modelos de cinética de adsorção. A adsorção e a cinética de adsorção de cádmio e chumbo em um Latossolo roxo foram investigadas por meio de ensaios de adsorção tipo Batch. As concentrações iniciais nas soluções variaram de 2 mg/L até 2000 mg/L. OS tempos de contatos variaram de 5 minutos até 6 meses. Também foram realizados ensaios de extração e digestão química. A seguir, foram aplicados modelos para determinar os mecanismos que controlam a cinética de adsorção e também foram ajustados modelos de cinética de adsorção aos dados experimentais. Os resultados mostram que a adsorção pode ser representada por dois distintos comportamentos: curto prazo, até cerca de 8 horas, e longo prazo, para tempos superiores. A adsorção não específica aumenta com o aumento da concentração do contaminante na fase sólida no caso do cádmio, enquanto para o chumbo esta relação não ficou clara. Os modelos de cinética de adsorção testados representam apenas o comportamento de curto prazo e o ajuste desses modelos aos dados experimentais, mesmo para a adsorção de curto prazo, varia consideravelmente em função do método matemático utilizado. Finalmente, concluiu-se que a cinética de adsorção é bem representada por uma função tipo potência com expoente negativo. / Metal adsorption in soils has been studied in the scope of environmental geotechnics mainly to predict migration of contaminant plumes, to study feasibility of remediation techniques, and to design waste disposal sites. The consideration of adsorption as an immediate and reversible phenomenon is generally accepted in those applications; however, the study of adsorption kinetics in tropical soils may improve back-calculation of field data and interpretation of experimental results. This study presents theoretical aspects of adsorption kinetics, including factors that affect adsorption kinetics, models to determine mechanisms that control adsorption kinetics and adsorption kinetics models. Adsorption and adsorption kinetics of cadmium and lead in a Brazilian lateritic red clay were investigated by means of Batch adsorption tests on. Initial solutions concentrations varied from 2 mg/L to 2000 mg/L. Contact times varied from 5 minutes to 6 months. Chemical extraction and digestion tests were also performed. Models were then applied to experimental data to determine the mechanisms that control adsorption kinetics and adsorption kinetics models were also fitted to experimental data. The results show that adsorption can be represented by two different behaviors: a short time behavior, until circa 8 hours, and a long time behavior, for longer times. For cadmium, the importance of non specific adsorption increases as the contaminant concentration in the solid phase increases, while this relation is not clear for lead. The investigated adsorption kinetics models can only represent the short time behavior, and fitting of these models, even for short-time adsorption, depends considerably on the utilized mathematical method. Finally, adsorption kinetics can be well represented by a power function with negative exponent.
|
Page generated in 0.0595 seconds