An electrocardiograph tutor using expert system technology

Meyer, Derek Louis January 1989 (has links)
Computer systems for the interpretation of diagnostic ECGs are widely used, but currently provide no explanatory or teaching functions of value to the less experienced practitioner. The relevant literature is reviewed, and specifications are provided for an ECG analysis system which will function as a learning aid for undergraduate and postgraduate medical students. Key aspects of the specifications are implemented on an IBM-PC. Recommendations for further development are provided.
222

Effekter av energidryck på korrigerad QT-tid, hjärtfrekvens och blodtryck på kvinnor : En placebostudie / Effects of energy drink on corrected QT interval, heart rate and blood pressure in women. - : A placebo study.

Memedovska, Zamira Edaet, Hsino, Bayan January 2023 (has links)
Syftet med denna placebostudie är att studera energidryckens effekter på QTc-tiden, hjärtfrekvens (HR), systoliskt blodtryck (SBP) och diastoliskt blodtryck (DBP) efter konsumtion av 2 mg koffein per kilogram kroppsvikt. Dessutom belysa om skillnader finns beroende på koffeinkonsumtions vanor. Variabler registrerades av ett 12-avlednings-elektrokardiogram och en automatiserad blodtrycksanordning. Undersökningen genomfördes före intag av sockerfri (ED) och 30–40 minuter efter ED konsumtion. I resultatet inkluderades 58 deltagare i åldrarna 18–30 år. En signifikant skillnad mellan QTc, HR, SBP och DBP identifierades före och efter konsumtion av ED, genom ett parvis t-test. Ingen signifikant skillnad identifierades på HR (P=0,2), SBP (P=0,4) och DBP (P=o,4) före och efter konsumtion av placebodryck. En signifikant skillnad på QTc (P=0,03) före och efter konsumtion av placebo dryck påvisades. Ingen signifikant skillnad påvisades mellan variablerna i relation till dryckerna, genom ett oberoende t-test. Ingen signifikant skillnad identifierades mellan variablerna, i relation till sällan konsumenter respektive ofta konsumenter, genom ett oberoende t-test. Ingen signifikant skillnad påvisades mellan ED respektive placebo dryck per konsumtions grupp, utfört med två-vägs ANOVA. / Effects of energy drink on corrected QT interval, heart rate and blood pressure in womena placebo study The purpose of this placebo study is to study the effects of the energy drink on the QTc time, heart rate (HR), systolic blood pressure (SBP), and diastolic blood pressure (DBP) after consumption of 2 mg of caffeine per kilogram of body weight. Additionally, highlight whether differences exist depending on caffeine consumption habits. Variables were recorded by a 12-lead-electrocardiogram and an automated blood pressure device. The survey was conducted before consuming a sugar-free energy drink (ED) and 30–40 minutes after ED consumption. The results included 58 participants aged 18-30 years. A significant difference between QTc, HR, SBP, and DBP was identified before and after consumption of ED, by a paired t-test. No significant difference was identified in HR (P=0.2), SBP (P=0.4), and DBP (P=0.4) before and after consumption of the placebo drink. A significant difference in QTc (P=0.03) before and after consumption of the placebo drink was demonstrated. No significant difference was detected between the variables about the drinks, through an independent t-test. No significant difference was identified between the variables, to infrequent and frequent consumers, using an independent t-test. No significant difference was detected between the ED and placebo drink per consumption group, performed with two-way ANOVA.
223

Estimation of Atrial Electrical Complexity during Atrial Fibrillation by Solving the Inverse Problem of Electrocardiography

Molero Alabau, Rubén 30 October 2023 (has links)
Tesis por compendio / [ES] La fibrilación auricular (FA) es la arritmia más prevalente en el mundo y está asociada con una elevada morbilidad, mortalidad y costes sanitarios. A pesar de los avances en opciones de tratamiento farmacológico y terapia de ablación, el manejo de la FA todavía tiene margen de mejora. La imagen electrocardiográfica (ECGI) se ha destacado como un prometedor método no invasivo para evaluar la electrofisiología cardíaca y guiar las decisiones terapéuticas en casos de fibrilación auricular. No obstante, el ECGI se enfrenta a desafíos como la necesidad de resolver de manera precisa el denominado problema inverso de la electrocardiografía y de optimizar la calidad de las reconstrucciones de ECGI. Además, la integración del ECGI en los procesos clínicos rutinarios sigue siendo un reto, en gran medida debido a los costos que supone la necesidad de imágenes cardíacas. Por ello, los objetivos principales de esta tesis doctoral son impulsar la tecnología ECGI mediante la determinación de sus requisitos técnicos mínimos y la mejora de las metodologías existentes para obtener señales de ECGI precisas. Asimismo, buscamos evaluar la capacidad de ECGI para cuantificar de forma no invasiva la complejidad de la FA. Para lograr estos objetivos, se han llevado a cabo diversos estudios a lo largo de la tesis, desde el perfeccionamiento del ECGI hasta la evaluación de la FA utilizando esta tecnología. En primer lugar, se han estudiado los requisitos geométricos y de señal del problema inverso mediante el estudio de los efectos de la densidad de la malla del torso y la distribución de electrodos en la precisión del ECGI, lo que ha conducido a la identificación del número mínimo de nodos y su distribución en la malla del torso. Además, hemos identificado que para obtener señales de ECGI de alta calidad, es crucial la correcta disposición de los electrodos en la malla del torso reconstruido. Asimismo, se ha definido y evaluado una nueva metodología de ECGI sin necesidad de usar técnicas de imagen cardiaca. Para ello, hemos comparado métricas derivadas del ECGI calculadas con la geometría original del corazón de los pacientes con las métricas medidas en diferentes geometrías cardíacas. Nuestros resultados han mostrado que el ECGI sin necesidad de imágenes cardíacas es efectivo para la correcta cuantificación y localización de los patrones y zonas que mantienen la FA. En paralelo, hemos optimizado la regularización de Tikhonov de orden cero actual y la optimización de la curva L para el cálculo de las señales ECGI, investigando cómo el ruido eléctrico y las incertidumbres geométricas influyen en la regularización. A partir de ello, propusimos un nuevo criterio que realza la precisión de las soluciones de ECGI en escenarios con incertidumbre debido a condiciones de señal no ideales. En segundo lugar, en esta tesis doctoral, se han llevado a cabo múltiples análisis relativos a diferentes metodologías de procesado de señales y obtención métricas derivadas del ECGI con el fin de caracterizar mejor el sustrato cardíaco y la actividad reentrante en las señales de ECGI de pacientes con FA. Con el objetivo de obtener una comprensión más profunda de los mecanismos electrofisiológicos subyacentes a la FA, hemos establecido la estrategia de filtrado óptima para extraer patrones reentrantes específicos del paciente y métricas derivadas de señales ECGI. Además, hemos investigado la reproducibilidad de los mapas de reentradas derivados de las señales de ECGI y hemos encontrado su relación con el éxito de la ablación de venas pulmonares (PVI). Nuestros resultados han mostrado que una mayor reproducibilidad en los patrones reentrantes de FA detectados con ECGI está relacionada con el éxito de la PVI, creando una metodología para estratificar a los pacientes con FA antes de los procedimientos de ablación. / [CA] La fibril·lació auricular (FA) és l'arrítmia més prevalent al món i està associada amb una elevada morbiditat, mortalitat i costos sanitaris. Malgrat els avanços en opcions de tractament farmacològic i teràpies d'ablació, el maneig de la FA encara té marge de millora. La imatge electrocardiogràfica (ECGI) s'ha destacat com un prometedor mètode no invasiu per a avaluar l'electrofisiologia cardíaca i guiar les decisions terapèutiques en casos de fibril·lació auricular. No obstant això, l'ECGI s'enfronta a desafiaments com la necessitat de resoldre de manera precisa el denominat problema invers de la electrocardiografia i d'optimitzar la qualitat de les reconstruccions de ECGI. A més, la integració del ECGI en els processos clínics rutinaris continua sent un repte, en gran manera a causa dels costos que suposa la necessitat d'imatges cardíaques. Per això, els objectius principals d'aquesta tesi doctoral són impulsar la tecnologia de l'ECGI mitjançant la determinació dels seus requisits tècnics mínims i la millora de les metodologies existents per obtenir senyals d'ECGI precises. A més, busquem avaluar la capacitat de l'ECGI per quantificar de forma no invasiva la complexitat de la FA. Per a aconseguir aquests objectius, s'han dut a terme diversos estudis al llarg de la tesi, des del perfeccionament de l'ECGI fins a l'avaluació de la FA utilitzant aquesta tecnologia. En primer lloc, hem estudiat els requisits geomètrics i de senyal del problema invers mitjançant l'estudi dels efectes de la densitat de la malla del tors i la distribució d'elèctrodes en la precisió de l'ECGI, el que ha conduït a la identificació del nombre mínim de nodes i la seva distribució en la malla del tors. A més, hem identificat que per obtindre senyals d'ECGI d'alta qualitat, és crucial la correcta disposició dels elèctrodes en la malla del tors reconstruïda. També s'ha definit i avaluat una nova metodologia d'ECGI sense necessitat d'utilitzar tècniques d'imatge cardíaca. Per a això, hem comparat mètriques derivades de l'ECGI calculades amb la geometria original del cor dels pacients amb les mètriques mesurades en diferents geometries cardíaques. Els nostres resultats han mostrat que l'ECGI sense necessitat d'imatges cardíaques és efectiu per a la correcta quantificació i localització dels patrons i zones que mantenen la FA. Paral·lelament, hem optimitzat la regularització de Tikhonov d'ordre zero actual i l'optimització de la corba L per al càlcul de les senyals d'ECGI, investigant com el soroll elèctric i les incerteses geomètriques influeixen en la regularització. Addicionalment, vam proposar un nou criteri que reforça la precisió de les solucions d'ECGI en escenaris amb incertesa degut a condicions de senyal no ideals. En segon lloc, en aquesta tesi doctoral, s'han dut a terme múltiples anàlisis relatius a diferents metodologies de processament de senyals i obtenció de mètriques derivades de l'ECGI amb l'objectiu de caracteritzar millor el substrat cardíac i l'activitat reentrant en les senyals d'ECGI de pacients amb FA. Amb l'objectiu d'obtindre una comprensió més profunda dels mecanismes electrofisiològics subjacents a la FA, hem establert l'estratègia de filtrat òptima per extreure patrons reentrants específics del pacient i mètriques derivades de senyals ECGI. A més, hem investigat la reproductibilitat dels mapes de reentrades derivats de les senyals d'ECGI i hem trobat la seva relació amb l'èxit de l'ablació de venes pulmonars (PVI). Els nostres resultats han mostrat que una major reproductibilitat en els patrons reentrants de FA detectats amb ECGI està relacionada amb l'èxit de la PVI, creant una metodologia per estratificar els pacients amb FA abans dels procediments d'ablació. / [EN] Atrial fibrillation (AF) is the most prevalent arrhythmia in the world and is associated with significant morbidity, mortality, and healthcare costs. Despite advancements in pharmaceutical treatment alternatives and ablation therapy, AF management remains suboptimal. Electrocardiographic Imaging (ECGI) has emerged as a promising non-invasive method for assessing cardiac electrophysiology and guiding therapeutic decisions in atrial fibrillation. However, ECGI faces challenges in dealing with accurately resolving the ill-posed inverse problem of electrocardiography and optimizing the quality of ECGI reconstructions. Additionally, the integration of ECGI into clinical workflows is still a challenge that is hindered by the associated costs arising from the need for cardiac imaging. For this purpose, the main objectives of this PhD thesis are to advance ECGI technology by determining the minimal technical requirements and refining existing methodologies for acquiring accurate ECGI signals. In addition, we aim to assess the capacity of ECGI for noninvasively quantifying AF complexity. To fulfill these objectives, several studies were developed throughout the thesis, advancing from ECGI enhancement to AF evaluation using ECGI. Firstly, geometric and signal requirements of the inverse problem were addressed by studying the effects of torso mesh density and electrode distribution on ECGI accuracy, leading to the identification of the minimal number of nodes and their distribution on the torso mesh. Besides, we identified that the correct location of the electrodes on the reconstructed torso mesh is critical for the accurate ECGI signal obtention. Additionally, a new methodology of imageless ECGI was defined and assessed by comparing ECGI-derived drivers computed with the original heart geometry of the patients to the drivers measured in different heart geometries. Our results showed the ability of imageless ECGI to the correct quantification and location of atrial fibrillation drivers, validating the use of ECGI without the need for cardiac imaging. Also, the current state of-the-art zero-order Tikhonov regularization and L-curve optimization for computing ECGI signals were improved by investigating the impact of electrical noise and geometrical uncertainties on the regularization. We proposed a new criterion that enhances the accuracy and reliability of ECGI solutions in situations with uncertainty from unfavorable signal conditions. Secondly, in this PhD thesis, several analyses, signal processing methodologies, and ECGIderived metrics were investigated to better characterize the cardiac substrate and reentrant activity in ECGI signals from AF patients. With the objective of obtaining a deeper understanding of the electrophysiological mechanisms underlying AF, we established the optimal filtering strategy to extract patient-specific reentrant patterns and derived metrics in ECGI signals. Furthermore, we investigated the reproducibility of the obtained ECGI-reentrant maps and linked them to the success of PVI ablation. Our results showed that higher reproducibility on AF drivers detected with ECGI is linked with the success of PVI, creating a proof-of-concept mechanism for stratifying AF patients prior to ablation procedures. / This work was supported by: Instituto de Salud Carlos III, and Ministerio de Ciencia e Innovación (supported by FEDER Fondo Europeo de Desarrollo Regional DIDIMO PLEC2021- 007614, ESSENCE PID2020-119364RB-I00, and RYC2018- 024346B-750), EIT Health (Activity code SAVE-COR 220385, EIT Health is supported by EIT, a body of the European Union) and Generalitat Valenciana Conselleria d’Educació, Investigació, Cultura i Esport (ACIF/2020/265 and BEFPI/2021/062). / Molero Alabau, R. (2023). Estimation of Atrial Electrical Complexity during Atrial Fibrillation by Solving the Inverse Problem of Electrocardiography [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/199029 / Compendio
224

Secure Chaotic Transmission of Digital and Analog Signals Under Profiled Beam Propagation in Acousto-Optic Bragg Cells with Feedback

Almehmadi, Fares Saleh S. 27 May 2015 (has links)
No description available.
225

The effects of atrial repolarization on exercise-induced ST-segment depression in apparently healthy females

Brown, Rhonda K. 11 July 2009 (has links)
The relationship between the PQ-segment slope on ST-segment depression during vigorous exercise was examined in 26 apparently healthy females between 18 and 26 years of age. Each subject performed 2 submaximal cycle ergometer exercise tolerance tests (trial A and trial B) on nonconsecutive days wherein the following variables, as delta scores, were measured; P-wave amplitude (microvolts), PQ-segment slope (uV!sec), and J-point at 0 and 60 msec (uV). Each variable was measured by both visual and computer averaging. The degree of reproducibility within and between trials differed for the visual and computer averaged measures. Generally higher reproducibility was found with computer averaging particularly within trial B (r =0.63-0.89, p<O.OI). Trial b served as a basis for assessment of PQ-segment slope effect on ST segment response. Computer analysis of frequency distribution for responses revealed a greater frequency of downsloping PQ-segment with clinically significant ST-segment depression (>50 uV) at both 0 and 60 msec after the J-point in lead II. However, there was a greater percentage (91%) of flat PQ-segment slopes with clinically significant ST-segment depression at J-point 0 msec in lead V5. These findings suggest possible influence of lead selection on the measurements of the PQ-segment slope and ST-segment. Implication of clinical application would be to use lead VS for diagnosing CHD and by measuring ST-segment depression at J-point 60 msec. However when screening exercise ECG tests in apparently healthy women use J-point at 0 msec. / Master of Science
226

Eventos arrítmicos em pacientes com canalopatias cardíacas submetidos à anestesia local odontológica: estudo piloto randomizado / Arrhythmic events in patients with cardiac channelopathies subjected to local dental anesthesia: a randomized pilot study

Oliveira, Ana Carolina Guimarães 14 May 2019 (has links)
Introdução: Distúrbios dos canais iônicos cardíacos potencialmente letais, como a síndrome de Brugada (SBr), a síndrome do QT longo congênito (SQTL) e a taquicardia ventricular polimórfica catecolaminérgica (TVPC) podem ser responsáveis por pelo menos um terço do total de casos de morte súbita que permanecem inexplicados. Estes pacientes, por vezes, não obtêm tratamento odontológico e analgesia adequados devido à falta de informações na literatura em relação à dose e tipo de anestésico local recomendado, e ao risco potencial de eventos cardíacos ameaçadores à vida e instabilidade hemodinâmica. Métodos: Trata-se de um estudo piloto, randomizado, duplo-cego e cruzado com portadores de canalopatias cardíacas submetidos a tratamento odontológico restaurador em duas sessões, realizadas com intervalo mínimo de sete dias (wash-out) entre ambas, sendo o paciente seu próprio controle. Na primeira sessão, por randomização, o paciente recebeu uma das soluções anestésicas: lidocaína 2% sem vasoconstritor (LSA) ou lidocaína 2% com adrenalina 1:100.000 (LCA), originando duas condições: sem adrenalina e com adrenalina; na segunda sessão recebeu o outro anestésico. Todos foram monitorados com Holter por 28 horas, contadas a partir de uma hora antes do procedimento, nas duas sessões do estudo. Durante o atendimento odontológico, foram feitos registros pontuais em três momentos por meio de eletrocardiograma de 12 derivações, esfigmomanômetro digital para pressão arterial e escala de mensuração da ansiedade. Resultados: Sessenta e dois procedimentos restauradores foram realizados em 31 pacientes: 16 (51,6%) tinham SQTL, 12 (38,7%) SBr e três (9,7%) TVPC, dentre os quais 12 (38,7%) eram portadores de cardiodesfibrilador implantável. A idade média dos pacientes foi 45,2+15,8 anos, sendo 21 (67,7%) do sexo feminino. Os valores médios da frequência cardíaca máxima se mostraram aumentados com o uso de LCA no período da anestesia (84,4 x 80,4 bpm; p=0,005) com diferença estatisticamente significante entre as duas condições, assim como o QTc em pacientes com SQTL (465,4 x 450,1; p=0,009). Valores de pressão arterial e mensuração da ansiedade não mostraram diferença estatisticamente significante. Não foram observadas arritmias ventriculares ameaçadoras à vida durante os procedimentos. Conclusões: O uso da anestesia local com lidocaína, independente do uso de vasoconstritor, não resultou em arritmias ameaçadoras à vida e foi considerado seguro nos pacientes selecionados. Estes resultados preliminares devem ser confirmados em uma população maior, em um estudo multicêntrico / Background: Ion channel disorders, such as Brugada syndrome (BS), long QT syndrome (LQTS), and catecholaminergic polymorphic ventricular tachycardia (CPVT), may account for at least one-third of unexplained sudden cardiac deaths. These patients often do not receive adequate dental treatment and analgesia owing to the lack of information in the literature regarding the dose and type of local anesthetic recommended, and due to the potential risk of life-threatening cardiac events. Methods: This is a randomized, double-blind pilot trial in patients with cardiac CCh underwent to restorative dental treatment in two sessions, with a wash-out period of 7 days (crossover trial). In the first session, by randomization, the patient received one of the anesthetic solutions: 2% lidocaine without vasoconstrictor (LSA) or 2% lidocaine with epinephrine 1: 100,000 (LCA), making two conditions: without epinephrine and with epinephrine; and in the second session received the other anesthetic. Twenty-eight-hour Holter monitoring was performed in all patients, initiated one hour before the procedure, in the two study sessions. During the dental treatment, additional specific monitoring including 12-lead electrocardiography (ECG), digital sphygmomanometry and anxiety scale assessments was also applied at three time points. Results: Sixty-two dental procedures were performed in 31 patients with CCh: 16 (51.6%) had LQTS, 12 (38.7%) had BS and three (9.7%) had CPVT; 12 (38.7%) patients had an implantable defibrillator. The mean age was 45.2+15.8 years, and 21 (67.7%) patients were female. The maximum heart rate was increased after the use of epinephrine during the anesthesia period (84,4 x 80,4 bpm, p=0.005), as well the corrected QT in LQTS patients (465,4 x 450,1; p=0,009). Blood pressure and anxiety measurements showed no statistically significant differences. No life-threatening arrhythmias occurred during the dental treatment. Conclusions: The use of local dental anesthesia with lidocaine, regardless of the use of a vasoconstrictor, did not result in life-threatening arrhythmias and was considered safe in these selected patients with channelopathies. These preliminary findings need to be confirmed in a larger population study, in a multicenter study
227

Impacto do uso rápido dos betabloqueadores sobre a mortalidade e remodelamento ventricular na insuficiência cardíaca avançada / Impact of rapid beta-blockers therapy on mortality and ventricular remodeling in advanced heart failure

Melo, Domingos Sávio Barbosa de 25 March 2011 (has links)
Fundamento: A terapia com betabloqueadores é fundamental para o tratamento da insuficiência cardíaca congestiva. Entretanto, apesar dos dados que documentam os benefícios dos betabloqueadores, a otimização da dose desses medicamentos durante a hospitalização ainda não foi testada. Objetivos: Avaliar a segurança da efetividade do betabloqueio rápido em pacientes hospitalizados por Insuficiência Cardíaca avançada. Métodos: Em estudo clínico randomizado, foram incluídos 92 pacientes com insuficiência cardíaca e fração de ejeção do ventrículo esquerdo <45%: 46 no grupo tratamento e 46 no grupo controle. Do total 59 (64,1%) pacientes eram do sexo masculino, com idade média de 62,25±14,43 anos. Durante o período de internação esses pacientes foram alocados aleatoriamente para receber incrementos da dose de betabloqueadores de forma rápida, a cada dois dias (grupo tratamento), ou a cada 15 dias (grupo controle). O desfecho principal foi a ocorrência de reinternação ou morte por causas diferentes. Foram considerados como efeitos adversos hipotensão arterial, bradicardia e piora da insuficiência cardíaca. Resultados: A fração de ejeção média do ventrículo esquerdo foi de 27,24±9,08, o diâmetro diastólico final médio 66,15±8,65 e o diâmetro sistólico final médio 57,04±9,96. No grupo tratamento, houve redução significativa do DSFVE em três meses e um ano (p<0,001), enquanto no grupo controle permaneceu inalterado (p=0,337). O DDFVE apresentou redução significativa (p=0,036) no grupo tratamento que não foi significativa no grupo controle (p=0,250). Houve aumento significativo da FEVE no grupo tratamento (p<0,001) em três meses, o que não ocorreu no grupo controle (p=0,151), mas não houve diferença entre os grupos em um ano. A distância percorrida no teste de caminhada de 6min aumentou significativamente (p<0,001) no grupo tratamento em relação ao grupo controle. O grupo tratamento apresentou probabilidade livre de internação significativamente maior que a do grupo controle (p=0,045). Com referência à sobrevida, o grupo tratamento apresentou níveis significativamente maiores que a do grupo controle no período avaliado (p=0,002). Conclusões: O incremento rápido da dose de betabloqueador durante a internação por descompensação de insuficiência cardíaca foi segura e melhorou a sobrevida, o remodelamento ventricular e a capacidade de fazer exercícios / Background: The beta-blocker therapy is essential in congestive heart failure treatment. However, despite data documenting, the benefits of beta-blockers, and the optimization of these medications dosage during hospitalization has not been tested. Objectives: To evaluate the safety of the efficiency of acute beta-blockade on hospitalized patients due to advanced heart failure. Methods: In a randomized clinical trial, 92 patients with heart failure and ejection fraction of left ventricle <45% were included: 46 in the treatment group and 46 in the control group. In the assessed group 59 (64.1%) patients were male, with mean age of 62.25 ± 14.43 years. During the hospitalization period and those who were randomized to acute beta-blocker dose increments, every other day (treatment group) or every 15 days (control group) were selected. The main outcome was the occurrence of rehospitalization or death for different causes. Hypotension, bradycardia, and worsening heart failure were considered as adverse effects. Results: The mean ejection fraction of left ventricle was 27.24±9.08, the average end-diastolic diameter 66.15±8.65 and the average end-systolic diameter 57.04±9.96. In the treatment group, significant reduction of DSFVE in three months and one year (p<0.001) has been observed, whereas in the control group remained unchanged (p=0.337). The LVEDD decreased significantly (p=0.036) in the treatment group and in the control group it was not significant (p=0.250). There was a significant increase of the LVEF in the treatment group (p<0.001) in three months, and no difference occurred in the control group (p=0.151), and no difference between groups in a year was observed. During the 6 min walking test the treatment group showed a significant distance increase (p<0.001) when compared with the control group. The treatment group had free admission probability significantly higher than the control group (p=0.045). As to patients survival, the treatment group showed significantly higher levels than the control group during the evaluation period (p=0.002). Conclusions: Fast increase of the beta-blockers dosage during hospitalization in decompensated heart failure was safe and improved survival, ventricular remodeling, and exercise capacity
228

Estudo das alterações da variabilidade da freqüência cardíaca e troponina no paciente séptico / Heart rate variability and troponin in septic patients

Nogueira, Antonio Carlos 24 April 2006 (has links)
CONTEXTO: Estudos observacionais têm demonstrado alterações na variabilidade da freqüência cardíaca em pacientes em sepse, embora não exista publicação correlacionando lesão cardíaca causada pela inflamação sistêmica e redução da variabilidade da freqüência cardíaca. OBJETIVOS: Determinar, em pacientes em sepse, se a lesão cardíaca é causa das alterações da variabilidade da freqüência cardíaca e sua correlação com a mortalidade. Analisar também a associação entre evolução clínica e variabilidade da freqüência cardíaca, troponina, lesão celular à microscopia eletrônica e óptica e variáveis hemodinâmicas. MÉTODO: Estudo observacional, prospectivo, entre pacientes que desenvolveram sepse grave ou choque séptico, analisando sobrevida. Foram analisados: variabilidade da freqüência cardíca (alta e baixa freqüência, através da monitorização cardíaca contínua), dosagem dos níveis séricos de troponina, creatinofosfoquinase e creatinofosfoquinase fração MB, proteína C-reativa, alterações morfológicas e funcionais das células cardíacas por microscopia óptica e eletrônica e imunoistoquímica. Os dados hemodinâmicos foram obtidos por ecocardiograma e medida direta por cateter de artéria pulmonar. RESULTADOS: Dos 31 pacientes incluídos, 12 (38,7%) morreram durante o acompanhamento de 6 dias e 13 sobreviveram até o 28o dia (41,9%); 6 pacientes (19,4%) morreram nas primeiras 6 horas do estudo. O índice APACHE, utilizado como marcador prognóstico, foi igual nos dois grupos (27 +/- 2,6 nos sobreviventes e 26 +/- 2 nos não sobreviventes). A troponina plasmática se mostrou marcador de disfunção miocárdica na sepse (sobreviventes: 0,53 +/- 0,13 mg/ml, e não-sobreviventes: 2,31 +/- 1,01 mg/ml, p < 0,05), com informação prognostica, e se correlacionou com os piores dados hemodinâmicos do grupo de não-sobreviventes (índice de trabalho sistólico do ventrículo esquerdo no grupo de sobreviventes de 48,1 +/- 6,7 g.m/m2 e no de não-sobreviventes de 34,0 +/- 6,7 g.m/m2, p < 0,05). A variabilidade da freqüência cardíaca diminuída se correlacionou com pior prognóstico e a análise multivariada apontou a baixa freqüência cardíaca como uma variável independente para predizer alta da unidade de terapia intensiva (280 +/- 25 ms2 nos sobreviventes e 84 +/- 7,2 ms2 nos pacientes que evoluiram a óbito, freqüência mínima 129 +/- 19 ms2 e 65 +/- 9 ms2 na freqüência máxima, p < 0,05). A microscopia do coração evidenciou infiltrado inflamatório difuso e aumento do número de mitocôndrias e destruição destas organelas. CONCLUSÃO: Nossos resultados sugerem que a alteração da variabilidade da freqüência cardíaca está relacionada com a evolução para óbito, e correlaciona-se com a lesão cardíaca diagnosticada pela dosagem de troponina sérica e alteração do índice do trabalho sistólico do ventrículo esquerdo por sístole. A histologia do coração demonstrou importante lesão celular do coração, com destruição e aumento do número de mitocôndrias. / CONTEXT: Observational studies have shown alterations in the variability of heart rate in patients with sepsis, although there is not a published study showing correlation to cardiac lesion caused by systemic inflammation and reduction on the heart rate variability. OBJECTIVE: To determine, in patients in sepsis, if the cardiac lesion is caused by the alteration on the heart rate variability and access its correlation with mortality; and also, to analyze the association between clinical evolution and cardiac rate variability, plasmatic troponin, cellular lesion on electronic microscopy and optic and the patients\' hemodynamic data. METHOD: Observational study among patients that developed sepsis or septic shock, analyzing the survivors\' rate. The heart rate variability was analyzed (high and low rate through continuous cardiac monitorization), as well as plasma levels of troponin, CK, CK-MB, C-reactive protein, the morphologic alterations and of cardiac cells function, through electronic and optic microscopy and through immunohistochemistry. The hemodynamics\' data were analyzed though echocardiogram and pulmonary artery catheter. RESULTS: Among 31 patients included, 12 (38.7%) of them died during the course of 6 days and 13 (41.9%) survived until the 28th day, 6 (19.4%) died within the first 6 hours of the study. The APACHE index, used as a prognostic marker, was the same in both groups (27 +/- 2.6 in the survivor group and 26 +/- 2.0 in the non-survivors group). The plasmatic troponin became a marker in the myocardial dysfunction in sepsis (survivors 0.53 +/- 0.13 mg/ml and non-survivors 2.31 +/- 1.01 mg/ml, p < 0.05), with prognostic information, and it correlated with the worst hemodynamic parameters among non-survivors group (left ventricle systolic index was 48.1 +/-6.7 g.m/m2 in survivors and 34.0 +/- 6.7 g.m/m2 in non survivors group, p < 0.05). The decrease on the heart rate variability was correlated with the worst prognoses and analyses pointed to a low rate as an independent variable to predict the patients discharge from the intensive care unit (280 +/- 25 ms2 among survivors and 84 +/-7.2ms2 among non-survivors). The heart microscopy showed diffused inflammatory infiltration and increase in the number of mitochondrias and lesions in these organelles. CONCLUSION: Our results suggest that the alteration of the variability on the heart rate is related with the evolution to death, and correlated to cardiac lesion, evidenced through the dosage of troponin, and to alteration of the systolic workload of the left ventricle by systole. The heart histology demonstrated important cellular lesion of the heart, with a raise in number of and damage to mitochondrias.
229

Avaliação dos fatores de risco de extrassístoles supraventriculares e ventriculares em pacientes ambulatoriais / Evaluation of risk factors of premature atrial and ventricular beats in outpatients

Ribeiro, Wilma Noia 17 May 2018 (has links)
As extrassístoles são achados frequentes em pacientes ambulatoriais, o que suscita o interesse em avaliar o seu significado clínico e fatores associados. O objetivo do estudo foi investigar as variáveis relacionadas com a presença de extrassístoles identificadas em pacientes ambulatoriais selecionados ao terem recebido a indicação de eletrocardiograma de rotina na rede básica de saúde. Foi realizado estudo transversal com 407 pacientes (idade média 55,8 anos ± 12 anos, 56% mulheres) encaminhados de Unidades Básicas de Saúde para o Hospital Municipal Doutor Fernando Mauro Pires da Rocha para realização de eletrocardiograma de repouso. Os participantes foram submetidos a questionário, exame físico, exames laboratoriais, ecocardiograma e monitorização eletrocardiográfica ambulatorial de 24 horas, a qual foi empregada para categorizar a frequência de extrassístoles. Depois de análise descritiva e exploratória, a regressão logística foi utilizada para avaliar as associações entre as variáveis. Extrassístoles supraventriculares ( >= 4/hora) se relacionaram com a idade (razão de chances 1,030; intervalo de confiança 95% 1,002 - 1,059; p=0,029), níveis de peptídeos natriuréticos > 20mg/dL (razão de chances 4,489; intervalo de confiança 95% 1,918 - 10,507; p=0.0005), bloqueios intraventriculares (razão de chances 4,184; intervalo de confiança 95% 1,861 - 9,406; p=0,0005) e diâmetro de átrio esquerdo (razão de chances 1,065; intervalo de confiança 95% 1,001 - 1,134; p=0,046). Extrassístoles ventriculares ( >= 5/hora) se associaram com a idade (razão de chances 1,032; intervalo de confiança 95% 1,010 - 1,054; p=0,004), uso de bloqueadores de canais de cálcio (razão de chances 2,248; intervalo de confiança 95% 1,019 - 4,954; p=0,045), níveis de peptídeos natriuréticos > 20mg/dL (razão de chances 2,079; intervalo de confiança 95% 1,062 - 4,068; p=0,033), taxas de HDL-colesterol (razão de chances 0,971; intervalo de confiança 95% 0,951 - 0,992; p=0,007), frequência cardíaca no eletrocardiograma (razão de chances 1,019; intervalo de confiança 95% 1,001 - 1,038; p=0,041), hipertrofia ventricular esquerda (razão de chances 2,292; intervalo de confiança 95% 1,402 - 3,746; p=0,001) e fração de ejeção ventricular esquerda (razão de chances 0,938; intervalo de confiança 95% 0,900 - 0,978; p=0,002). Na população estudada, os batimentos prematuros foram achados recorrentes e de baixa densidade na eletrocardiografia dinâmica de 24 horas. Extrassístoles mais frequentes se associaram a níveis de peptídeos natriuréticos > 20mg/dL e taxas mais baixas de HDL-colesterol; além disso, foi identificada maior dilatação atrial e hipertrofia ventricular no ecocardiograma dos pacientes com esse achado, sugerindo acometimento de órgão alvo decorrente de hipertensão arterial não controlada. Portanto, a detecção de extrassístoles frequentes na monitorização eletrocardiográfica de 24 horas, em pacientes acompanhados no nível de atenção primária, reitera as recomendações dirigidas principalmente para os cuidados com os fatores de risco associados com a sua presença / Premature complexes are common findings in outpatients; thus, it is important to evaluate their clinical significance and related factors. The aim of our study was to examine the variables associated with premature beats identified in outpatients who were followed by general practitioners in a primary public healthcare setting. We performed a cross-sectional study of 407 outpatients (mean age: 55.8±12 years; 56% women) who were referred from Basic Health Units to Doctor Fernando Mauro Pires da Rocha Municipal Hospital to perform a resting 12-lead electrocardiogram for clinical follow-up. They answered a questionnaire and submitted the physical examination, fasting laboratory testing, transthoracic echocardiogram and 24-hour Holter monitoring, which were used to categorize the frequency of premature complexes. After the univariate analysis, logistic regression analyses were performed to evaluate the independent association among the variables. Premature atrial complexes ( >= 4/hour) were associated with age (odds ratio 1.030; confidence interval 95% 1.002 - 1.059; p=0.029), peptide natriuretic levels > 20mg/dL (odds ratio 4.489; confidence interval 95% 1.918 - 10.507; p=0.0005), intraventricular blocks (odds ratio 4.184; confidence interval 95% 1.861 - 9.406; p=0.0005) and left atrium diameter (odds ratio 1.065; confidence interval 95% 1.001 - 1.134; p=0.046). Premature ventricular complexes ( >= 5/hour) were associated with age (odds ratio 1.032; confidence interval 95% 1.010 - 1.054; p=0.004), the use of calcium channels blockers (odds ratio 2.248; confidence interval 95% 1.019 - 4.954; p=0.045), peptide natriuretic levels > 20mg/dL (odds ratio 2.079; confidence interval 95% 1.062 - 4.068; p=0.033), HDL-cholesterol levels (odds ratio 0.971; confidence interval 95% 0.951 - 0.992; p=0.007), heart rate (odds ratio 1.019; confidence interval 95% 1.001 - 1.038; p=0.041), left ventricle hypertrophy (odds ratio 2.292; confidence interval 95% 1.402 - 3.746; p=0.001) and left ventricle ejection fraction (odds ratio 0.938; confidence interval 95% 0.900 - 0.978; p=0.002). In our population, premature complexes were common findings on 24-hour Holter monitoring, but of low density. Frequent ectopic beats were associated with peptide natriuretic levels > 20mg/dL and lower levels of HDL-cholesterol; left atrial enlargement and ventricular hypertrophy were also identified on the echocardiograms of these patients, suggesting that target organ damage was due to uncontrolled arterial hypertension. Therefore, the identification of frequent premature complexes on 24-hour Holter monitor recording of outpatients in a primary public healthcare setting reaffirms the need for monitoring for the risk factors associated with this finding
230

Estudo de relações ecodoplercardiográficas, eletrocardiográficas, ultrassonográficas e radiológicas em pacientes renais crônicos.

Loureiro, Afonso Augusto Carvalho 28 September 1995 (has links)
Made available in DSpace on 2016-01-26T12:51:12Z (GMT). No. of bitstreams: 1 afonsoloureiro_dissert.pdf: 209300 bytes, checksum: d0ce44c43c2878a31e7b4416e0396165 (MD5) Previous issue date: 1995-09-28 / Forty patients with end stage renal disease, twenty hipertensives and twenty healthy persons comprised the object of the authors s survey. Ecocardiography has shown to be the earliest and most sensitive method of heart enlargement in patients with hypertensive disease. Rx and Ecg are easily done although not sensitive. The authors s choice of ecocardiography as the simpliest and accurate method of ventricular hypertrophy is in accordance with literature data. / O autor estudou uma população de 20 pessoas "sadias", 20 pacientes hipertensos com função renal normal e 40 pacientes portadores de uremia. Encontrou variações estatisticamente significantes quanto avaliou imv através do exame ecodoplercardiográfico. Em relação ao exame eletrocardiográfico as alterações foram pouco evidentes. Foram encontrados resultados não coincidentes aos apresentados pelos critérios de hricak (1982). Os resultados encontrados através do índice cardiotorácico foram semelhantes aos da literatura. Pôde ainda demonstrar através dos resultados na metodologia empregada que pode ser usada como diagnóstico. Foram analisados parâmetros relacionados á creatinina e uréia que evienciaram dessemelhanças entre os pacientes.