• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 50
  • 15
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 81
  • 81
  • 81
  • 70
  • 49
  • 47
  • 45
  • 39
  • 31
  • 28
  • 27
  • 21
  • 18
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Effects of Two Therapeutic Modalities on Acute Muscle Soreness

Kopec, Thomas J., ATC 09 June 2009 (has links)
No description available.
42

Effects of TENS on Voluntary Quadriceps Activation and Vertical Ground Reaction Force During Walking in Subjects with Experimental Knee Pain

Son, Seong Jun 01 May 2014 (has links) (PDF)
Context: Knee pain is a common symptom in knee pathology and is associated with alterations in quadriceps activation and movement patterns. Reducing pain through intervention may help reestablish neuromuscular function. The independent effects of knee pain are difficult to examine and unclear. Objective: To investigate the effects of transcutaneous electrical nerve stimulation (TENS) on quadriceps activation and vertical ground reaction force (VGRF) during walking. Design: Crossover. Setting: Laboratory. Subjects: 15 in the TENS group (10M and 5F, 23.5 ± 2.8 yrs, 70.5 ± 12.5 kg, 178.1 ± 7.4 cm), and 15 in the sham group (10M and 5F, 22.5 ± 2.0 yrs, 72.1 ± 13.7 kg, 177.5 ± 9.3 cm). Interventions: Subjects underwent three experimental conditions (pain, sham, and control). Measurements were recorded across four time points (preinfusion, infusion, treatment, and posttreatment). Hypertonic or isotonic saline, respectively, was infused into the infrapatellar fat pad for 48 minutes (total 7.7 mL). The TENS group received a 20-minute treatment. A sham treatment was administered to the sham group. Main Outcome Measures: Perceived knee pain on a 10-cm visual analog scale, knee extension maximum voluntary isometric contraction (MVIC) normalized to body mass, knee extension central activation ratio (CAR), and VGRF. Results: Knee pain peaked at 4 cm during infusion and remained consistent across time in the sham group (F2,28 = 49.90, P < 0.0001), while knee pain gradually decreased to 1.5 cm following TENS treatment (F2,28 = 23.11, P < 0.0001). A group x condition x time interaction was detected for both the MVIC (F6,168 = 2.92, P < 0.01) and CAR (F6,168 = 3.03, P < 0.008) measurements. Post hoc analysis revealed that the infusion of hypertonic saline reduced knee extension MVIC by 29% in the TENS group, and by 26% in the sham group (P < 0.05). However, while the MVIC remained depressed by 26% following sham treatment, the MVIC was found to improve by 12% following TENS treatment (P < 0.05). Similarly, a 10% decrease in CAR was detected in both sham and TENS groups prior to treatment. This 10% deficit held, with a 9% deficit following sham treatment, while the deficit of CAR was improved by 4% following TENS treatment (P < 0.05). For the TENS group, infusion of hypertonic saline changed VGRF at initial loading, midstance, and push-off phase. VGRF was only different at initial loading and push-off phase following TENS treatment. For the sham group however, sham treatment did not restore VGRF, showing alterations in initial loading, midstance, and push-off phase (α = 0.05). Conclusions: Infusion of hypertonic saline increased perceived knee pain, reduced knee extension MVIC, reduced CAR, and altered VGRF over some of stance phase. TENS lessened the deficits in MVIC, CAR, and VGRF, suggesting decreased muscle inhibition and improved movement function.
43

Åtgärder för att motverka och lindra symtom vid muntorrhet hos vuxna : En allmän litteraturstudie / Measures to prevent and relieve symptoms of dry mouth in adults

Milosheska, Marija, Osawese Eguabor, Lidia January 2022 (has links)
Bakgrund: Muntorrhet är vanligt förekommande i den vuxna befolkningen och epidemiologiska studier visar att dess förekomst ökar med åldern vilket leder till att salivproduktionen minskar, vilket är en följd av systemiska sjukdomar, läkemedel och strålbehandling av huvud- och halscancer. Syftet: Syftet med studien var att beskriva olika åtgärder som finns för att lindra muntorrhet hos vuxna. Metod: Studien har genomförts i form av en litteraturstudie med kvantitativ metod. Vetenskapliga artiklarna söktes efter i tre olika databaser med totalt 21 artiklar som redovisades i en artikelmatris. Artiklarna publicerades mellan 2000–2021 och åldersgräns &gt;18 år. Resultat: Resultatet har visat flera olika metoder och åtgärder för att lindra och motverka muntorrhet hos vuxna individer. Bland de åtgärderna har läkemedel, salivstimulerade tugg- och sugtabletter, munspray/gel samt akupunkur, elektrisk nervstimulering och LLLT använts. Slutsats: Litteraturstudien har redovisat olika metoder som finns för att lindra muntorrhet hos vuxna människor men nya studier behövs för att förstärka resultatet samt komma fram till fler metoder för att lindra muntorrhet. / Abstract: Dry mouth is common in the adult population and epidemiological studies show that its prevalence increases with age leading to a decrease in saliva production, which is a consequence of systemic diseases, drugs and radiotherapy for head- and neck cancer. Aim: The aim of this study is to describe the various measures available to alleviate dry mouth in adults. Method: The study was conducted as a literature review using quantitative methods. The scientific articles were searched in three different databases, a total of 21 articles presented in an article matrix table. The articles were published between 2000-2021 and the age limit was &gt;18 years. Result: The results have shown several different methods and measures to alleviate and counteract dry mouth in adults. Among those measures, medications; pilocarpine and cervemelin, saliva stimulated tablets, mouth spray/gel as well as Acupuncture, TENS and LLLT have been used. Conclusion: The literature review has reported various methods available to alleviate dry mouth in adults, but new studies are needed to strengthen the results and more methods to alleviate dry mouth.
44

Efficacité analgésique de la neurostimulation périphérique (TENS) chez les aînés / Analgesic efficacy of transcutaneous electrical nerve stimulation (TENS) in the elderly

Bergeron-Vézina, Kayla January 2015 (has links)
La neurostimulation périphérique (en anglais transcutaneous electrical nerve stimulation ou TENS) est une modalité thérapeutique fréquemment utilisée en réadaptation pour diminuer la douleur. À ce jour, cependant, l’efficacité analgésique du TENS chez les aînés demeure peu documentée. La majorité des études effectuées jusqu’à présent ont été réalisées chez les jeunes adultes ou chez des populations d’âge hétérogènes. La présente étude, un essai croisé randomisé à double insu, avait pour objectif de documenter l’efficacité analgésique du TENS conventionnel et du TENS acupuncture chez les aînés et d’observer si la réponse analgésique de ces deux modalités de TENS entre les aînés et les jeunes adultes est différente. Quinze aînés et quinze jeunes adultes ont participé à l’étude. Les participants étaient évalués à trois occasions distinctes pour recevoir en alternance un TENS conventionnel, un TENS acupuncture et un TENS placebo. Une douleur expérimentale était créée à l’aide d’une thermode de type Peltier, appliquée au niveau de la colonne lombaire pendant deux minutes, période durant laquelle les participants devaient évaluer l’intensité de leur douleur avec une échelle visuelle analogue reliée à un ordinateur (CoVAS). Les mesures de douleur ont été prises avant, pendant et après l’application de chaque type de TENS. Chez les jeunes adultes, lorsque comparée au niveau de douleur initiale, une diminution significative de la douleur a été observée pendant et après l’application du TENS conventionnel et acupuncture. Le TENS conventionnel et acupuncture étaient supérieurs au traitement placebo (toutes les valeurs de p < 0,05). Cependant, chez les aînés, le TENS conventionnel et acupuncture n’ont pas permis de diminuer significativement la douleur. De plus, aucune modalité TENS ne se démarquait du traitement placebo (toutes les valeurs de p > 0,05). Bien que le TENS conventionnel et le TENS acupuncture soient efficaces chez les jeunes adultes, les présents résultats suggèrent que le TENS n’est pas la meilleure option de traitement pour diminuer la douleur chez les aînés, du moins lorsqu’il est utilisé seul (monothérapie). Des études futures, visant à déterminer des façons de bonifier l’effet du TENS chez les aînés, sont nécessaires.
45

An investigation of the prevalence and treatment of pain in a multiple sclerosis population

Warke, Kim January 2005 (has links)
No description available.
46

Avaliação da eletroestimulação nervosa transcutânea para alívio da dor de contração uterina pós-parto durante a amamentação: ensaio clínico randomizado / Assessment of transcutaneous electrical nerve stimulation to relieve the painful postpartum uterine contractions during breastfeeding: a randomized clinical trial

Sousa, Ligia de 20 October 2011 (has links)
Durante a amamentação ocorre a liberação de ocitocina para a ejeção do leite, que desencadeia a contração uterina, associada a processo doloroso. A Eletroestimulação Nervosa Trânscutânea (TENS) é um recurso fisioterapêutico que tem como função o alívio da dor. O objetivo principal deste estudo foi avaliar a efetividade da TENS para alívio de dor de contração uterina durante a amamentação em multíparas após o parto vaginal. Como objetivo específico visou mensurar e caracterizar a dor de contração uterina e identificar queixas álgicas durante a amamentação. Trata-se de um estudo clínico controlado e randomizado, composto por 32 multíparas após o parto vaginal, durante a amamentação. O estudo foi desenvolvido dentro dos padrões éticos, sendo aprovado pelo Comitê de Ética em Pesquisa da Escola de Enfermagem de Ribeirão Preto - USP. O estudo foi realizado em uma maternidade no interior do estado de São Paulo. As participantes foram alocadas de maneira aleatória, no alojamento conjunto. As participantes foram divididas em dois grupos, o grupo experimental (GE) que recebeu a aplicação de TENS convencional e o grupo controle (GC). Para o GE os eletrodos da TENS convencional foram posicionados na região paravertebral (T10-L1 e S2- S4), programado para gerar frequência de 80Hz, duração de pulso de 100?s e amplitude ajustada para produzir sensação forte e tolerável. O aparelho foi aplicado por 40 minutos. As puérperas foram avaliadas pela Escala de Categoria Numérica (NRS) e pela Intensidade de Dor Presente (PPI), em duas mamadas, correspondentes a primeira e segunda avaliação. Durante a primeira avaliação as puérperas foram questionadas quanto as características da dor e a presença de outras queixas dolorosas. Na segunda avaliação, o GE recebeu a TENS convencional durante a amamentação e o GC foi apenas acompanhado pelo mesmo período. Após a retirada da TENS do GE e acompanhamento do GC, as mulheres foram questionadas novamente em relação ao nível de dor. Ao final, as puérperas do GE responderam sobre a satisfação do tratamento e desconforto da corrente. Foi realizada análise descritiva para apresentação dos dados e análise comparativa entre os grupos, por meio de teste nãoparamétrico, com nível de significância p<=0,05. A dor de contração uterina apresentou as seguintes características: profunda, localizada em região de baixo ventre e ritmada. O início e diminuição da dor associaram-se com o início e término da sucção, respectivamente. As queixas dolorosas associadas foram dor nas mamas, na região perineal, nos membros superiores e inferiores, na região cervical e na coluna. O PPI indicou que as maiorias das participantes tiveram dor avaliada como moderada e o nível de dor pela NRS foi de 5,53. Na análise intragrupo o GE apresentou redução significativa da dor pela NRS (p<0,0001) após o uso da TENS. O GC também mostrou redução significativa da dor entre a primeira e segunda avaliação (p=0,04). Na análise intergrupo, o GE teve redução significativa da dor pelo PPI (p<0,001) e pela NRS (p<0,01) quando comparado ao GC. As puérperas que utilizaram a TENS relataram estar muito satisfeitas ou satisfeitas com o recurso, utilizariam a técnica em puerpério futuro e não sentiram desconforto causado pela corrente da TENS convencional. A intervenção não causou nenhum tipo de efeitos adversos e colaterais no GE. A TENS convencional foi eficaz no alívio de dor de contração uterina após o parto e durante a amamentação, podendo ser método de escolha para alívio deste tipo de dor. / During breastfeeding occurs the release of oxytocin for milk ejection, that cause uterine contractions associated with painful process. The transcutaneous electrical nerve stimulation (TENS) is a physical therapy resource, which aims to pain relief. The main objective of this study was to evaluate the effectiveness of TENS to relief of painful uterine contraction during lactation in multiparous after vaginal delivery. The specific objectives were to measure and characterize the uterine contraction pain and identify pain complaints during breastfeeding. This is a randomized, controlled clinical study, formed by 32 multiparous after vaginal delivery, during breastfeeding. The study was conducted with ethical standards and was approved by the Ethics Committee of the Nursing School of Ribeirão Preto - USP. The study was accomplished in a maternity hospital in the state of São Paulo. The participants were placed randomly. The participants were divided in two groups, the experimental group (EG) received the application of conventional TENS and the control group (CG). For EG, the electrodes were placed in the paravertebral region (T10-L1 and S2-S4), programmed to generate frequency of 80Hz, pulse duration of 100?s and intensity adjusted to cause strong feeling and tolerable. The device was applied for 40 minutes. The women were evaluated by Category Numeric Scale (NRS) and Present Pain Intensity (PPI), in two feedings, corresponding to the first and second evaluation. During the first assessment women were asked about pain characteristics and the presence of other pain complaints. In the second evaluation, EG received conventional TENS during breastfeeding and the CG were only accompanied by the same period. After remove the conventional TENS of the EG and monitoring the CG, the women were asked again in relation to the level of pain. In the end, the participants of the EG responded about treatment satisfaction and discomfort of the current. Descriptive analysis was performed for the presentation of data and comparative analysis between the groups, using non-parametric test, with significance level p <= 0.05. The painful uterine contraction had the following characteristics: deep, located in a lower abdomen and rhythmic. The onset and decreased pain associated with the start and end suction, respectively. The pain complaints were breast pain, perineal, in upper extremity, lower extremity, neck and spine. The PPI indicated that the most participants were assessed as moderate pain and pain level was 5.53 for the NRS. In the EG intragroup analysis showed a significant reduction of pain by the NRS (p <0.0001) after use of TENS. The GC also showed significant reduction in pain between the first and second evaluation (p = 0.04). In the intergroup analysis, the EG had significant reduction in pain by the PPI (p <0.001) and the NRS (p <0.01) when compared to CG. The women who used TENS reported being very satisfied or satisfied with the resource, using the technique in future puerperium and felt no discomfort caused by the current of conventional TENS. The intervention did not cause any adverse effects and side effects in EG. The conventional TENS was effective in relieving of uterine contraction pain after delivery and during breastfeeding, may be the method of choice for this type of pain relief.
47

Estimulação elétrica nervosa transcutânea do membro superior para reabilitação funcional da mão em pacientes com artrite reumatoide / Transcutaneous electrical nerve stimulation of upper limb for functional rehabilitation of the hand in patients with rheumatoid arthritis

Rodriguez, Antônio dos Santos 10 December 2014 (has links)
A artrite reumatóide é uma doença inflamatória crônica associada a alta morbidade, perda da produtividade e redução da expectativa de vida. Os pacientes requerem uma atendimento multidisciplinar para o controle da doença, reduzindo a inflamação e prevenindo a atrofia e deformação articulares. A estimulação elétrica nervosa transcutânea (TENS) tem se demonstrado no controle da dor articular, mas ainda há controvérsias sobre sua eficácia na reabilitação funcional da mão nesses pacientes. Este é um estudo cego, placebo-controlado, cruzado para comparar parâmetros funcionas da mobilidade da mão em pacientes com artrite reumatóide antes, durante e ao final de um período de 12 semanas de aplicação de TENS-burst em pontos sensitivos do membro superior. Na aplicação terapêutica utilizou-se intensidade de corrente de 10mA para estimulação das articulações metacarpofalangeanas e 20mA para os pontos sensorias do braço. Após uma pausa de um mês no tratamento, os pacientes que inicialmente receberam a estimulação terapêutica passaram a receber a estimulação placebo e vice-versa. Os resultados mostraram que a eletroestimulação terapêutica produziu mudanças positivas graduais e lineares na reabilitação funcional da mão analisado-se parâmetros de força e precisão de preensão das mãos, levando os pacientes à uma independência na execução de atividade de vida diária. O tratamento placebo mostrou-se ineficiente para a recuperação dos parâmetros avaliados. As habilidades conquistadas pelos pacientes que receberam inicialmente a eletroestimulação terapêutica foram perdidas durante o período de repouso, sugerindo que a manutenção da função da mão depende da continuidade do tratamento ao longo do tempo / Rheumatoid arthritis is a chronic inflammatory disease associated with high morbidity, loss of productivity and reduced life expectancy. Patients require multidisciplinary treatment to control the disease by reducing inflammation and preventing atrophy and joint deformation. Transcutaneous electrical nerve stimulation (TENS-burst) has been shown to control joint pain, but there is still controversy about its efficacy in functional hand rehabilitation in these patients. This is a blind, placebo-controlled, crossover study to compare the functional parameters of the mobility of the hand in rheumatoid arthritis patients before, during and after a period of 12 weeks of application of TENS- burst in the sensory points of the arm and metacarpophalangeal joints . In therapeutic application we used a current of 10mA for stimulation of joints and 20mA for the sensory points of the arm. After a month-long pause in treatment, patients who initially received therapy stimulation began receiving the placebo stimulation and vice versa. The results showed that therapeutic electrical stimulation produced gradual and linear positive changes in functional rehabilitation of the hand, accessed by analysis of strength and accuracy parameters of prehension, leading patients to independence in performing their daily living activities. The placebo treatment was inefficient for the recovery of the parameters evaluated. Skills achieved by patients who initially received therapeutic TENS-burst were lost during the rest (washing out) period, suggesting that the maintenance of hand function in rheumatoid artherits patients depends on the continuity of TENS-burst treatment
48

Estudo da estimulação elétrica nervosa transcutânea (TENS) nível sensório para efeito de analgesia em pacientes com osteoartrose de joelho / Study of transcutaneous electrical nerve stimulation (TENS) for the sensory effect of analgesia in patients with knee osteoarthritis

Morgan, Charles Ricardo 13 December 2010 (has links)
INTRODUÇÃO: A osteoartrose de joelho (OAJ) é uma das patologias que mais afetam o aparelho locomotor e interferem de forma considerável nas atividades da vida diária, acometendo os indivíduos em faixa etária variável e em diversos graus e níveis de dor articular. As propostas terapêuticas são bastante diversificadas para a osteoartrose (OA), a terapia física, a TENS está para colaborar no tratamento dos pacientes com osteoartrose de joelho. OBJETIVOS: Devido à importância da articulação do joelho nas atividades locomotoras e sua relação com as atividades da vida diária. Os pacientes com osteoartrose de joelho sofrem não somente pelo problema localizado, existe uma alteração funcional global que pode levar a processos dolorosos em outras articulações. Para uma eficaz orientação e avaliação do paciente primeiro é necessário que este faça a descrição clara de sua dor para que o profissional perceba como que esse estímulo doloroso prejudica sua vida. O objetivo do presente estudo foi avaliar o efeito da estimulação elétrica nervosa transcutânea (sigla em inglês TENS) nível sensório para tratamento de dor em pacientes com diagnóstico de osteoartrose de joelho, utilizando escalas de avaliação de dor, escala de avaliação funcional. MÉTODOS: Foram estudados 10 pacientes com diagnóstico de osteoartrose de joelho, utilizando uma modalidade fisioterapêutica, a eletroterapia, especificamente a (TENS), com parâmetros de 80 Hz e 140s, com um total de 10 sessões, 30 minutos para cada sessão, o período total de tratamento compreendeu 4 semanas, nesse total de 10 sessões, cada paciente foi entrevistado com um questionário na 1ª sessão, na 5ª e na 10ª sessão. Os formulários utilizados foram Questionário da Dor McGill Melzack, escala Analógica visual da dor, escala numérica com expressão facial de sofrimento, escala de atividades da vida diária da knee Outcome Survey - RESULTADOS: O resultado com a TENS nível sensório para efeito de analgesia mostra que as diferenças foram estatisticamente significativas (p<0,05) para escala Analógica visual da dor e o Questionário da Dor McGill, em alguns itens da escala de atividades da vida diária da knee Outcome Survey houve significância estatística. CONCLUSÃO: Nossos resultados sugerem que a TENS nível sensório reduz a dor e melhora a funcionalidade do joelho em alguns pontos da escala de atividades da vida diária em pacientes com OAJ / INTRODUCTION: Knee osteoarthritis (KOA) is one of the diseases that most affect the locomotor system and interfere significantly in activities of daily life, affecting individuals at varying ages and in different degrees and levels of joint pain. The proposals are quite diverse therapies for osteoarthritis (OA), physical therapy, TENS is to collaborate in the treatment of patients with osteoarthritis of the knee. OBJECTIVES: Because of the importance of the knee joint in locomotor activity and its relation to the activities of daily living. Patients with osteoarthritis of the knee not only suffer the problem located, there is a change in overall functional processes that can lead to pain in other joints. To provide efficient guidance and evaluation of the patient first must make this clear description of their pain for the professional to realize how painful stimulus that affect their lives. The aim of this study was to evaluate the effect of transcutaneous electrical nerve stimulation (TENS acronym in English) to the sensory processing of pain in patients with osteoarthritis of the knee, using rating scales of pain, functional scale. METHODS: We studied 10 patients with osteoarthritis of the knee, using a modality physiotherapy, electrotherapy, specifically (TENS), with parameters of 80 Hz and 140s, with a total of 10 sessions, 30 minutes for each session, the period Total treatment included 4 weeks in total of 10 sessions, each patient was interviewed with a questionnaire in the first session, on the 5th and 10th session. The forms used were the McGill Pain Questionnaire - Melzack, visual analogue pain scale, numerical scale with facial expression of pain, range of activities of daily living of the Knee Outcome Survey - RESULTS: The result with TENS for the effect of sensory analgesia shows that the differences were statistically significant (p <0.05) for visual analogue pain scale and McGill Pain Questionnaire, in some items of the scale of activities of daily living knee Outcome Survey of statistical significance. CONCLUSION: Our results suggest that sensory TENS reduces pain and improves knee function in some points of the scale of activities of daily living in patients with KOA
49

Estudo randomizado, cruzado e duplo cego para a avaliação da eletroestimulação intravaginal no tratamento da dor pelvica cronica / Randomized double - blind crossover clinical trial on the use of intravaginal electrical stimulation for the treatment of chronic pelvic pain

Bernardes, Nicole de Oliveira 07 November 2018 (has links)
Orientador: Luis Guillermo Bahamondes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-11-07T16:48:31Z (GMT). No. of bitstreams: 1 Bernardes_NicoledeOliveira_D.pdf: 943074 bytes, checksum: 77f689a7ae54f986db640511ff0b65b9 (MD5) Previous issue date: 2009 / Resumo: Este estudo avaliou a eficácia da eletroestimulação intravaginal com corrente ativa (EIVA) comparada a um grupo de controle com eletroestimulação intravaginal sem corrente ativa (placebo) (EIVP) em mulheres com dor pélvica crônica (DPC). Foi realizado um ensaio clínico controlado, duplo-cego, randomizado cruzado. Foram avaliadas 26 mulheres com DPC sem causa aparente, que foram submetidas a 10 sessões de eletroterapia intravaginal com corrente ativa e 10 sessões de eletroterapia intravaginal sem corrente ativa (placebo). O estudo foi realizado na Seção de Fisioterapia do Centro de Atenção Integral à Saúde da Mulher da Universidade Estadual de Campinas. Foi utilizado o programa para dor crônica difusa com frequência de 8Hz, com variação de intensidade e frequência, largura de pulso de1mS e intensidade suportável para cada paciente (em mA). O tratamento foi realizado duas a três vezes por semana em aplicações de 30 minutos e a dor foi avaliada através da escala análoga visual, antes e após cada sessão, e imediatamente após o tratamento completo. Quinze mulheres foram alocadas inicialmente para o grupo EIVA e 11 para o grupo EIVP. Comparando-se a intensidade da dor ao longo do tempo, observou-se que ambos os grupos reduziram a queixa de dor pélvica, porém a EIVA foi mais eficiente em aliviar os sintomas dolorosos (p = 0,0005) em comparação a EIVP (p= 0,0253). A eficácia da EIVA foi confirmada quando se cruzaram os dados para os grupos de tratamento. A diminuição da dor foi estatisticamente significativa em todas as ocasiões, quando se mudou do grupo placebo para o ativo (p=0,0361). As queixas de dispareunia superficial e profunda não apresentaram alteração ao longo dos tratamentos, independentemente do grupo no qual a mulher iniciou o estudo. Em conclusão, EIVA foi mais eficaz do que EIVP no alívio dos sintomas dolorosos de mulheres com DPC / Abstract: This study assessed the efficacy of intravaginal electrical stimulation (IVES) or placebo in the treatment of women with chronic pelvic pain (CPP) with no apparent cause. It was conducted a double-blind cross over randomized clinical trial in which 26 women were allocated either to IVES with active electrode (IVESA) or IVES without active electrode (IVESP). Each woman underwent 10 sessions of IVES at random with or without electrical stimulus. After previous sessions, they were submitted to the same program; however, on the contrary to a previous treatment. A program to difuse chronic pain was used with a frequency of 8Hz with na intensity variation and pulse amplitude of 1mS and intensity according to each patient (in mA). The treatment was performed two to three times a week with applications of 30 minutes and the pain was assessed through the visual analogue scale (VAS) before and after each session and after the total treatment. The results showed that the IVES with active electrode was more effective (p = 0.0005) than IVES without active electrode (p= 0.0253). Dyspareunia was not significantly reduced after the treatment. Intravaginal electrical stimulation was more efficient than placebo in the alleviation of pain in women with CPP / Doutorado / Tocoginecologia / Doutor em Tocoginecologia
50

O papel da estimulação vagal elétrica no tratamento de pacientes com epilepsia refratária / The role of electrical vagus nerve stimulation in the treatment of patients with refractory epilepsy

Oliveira, Tatiana von Hertwig Fernandes de 07 March 2016 (has links)
A estimulação elétriva vagal (VNS) é uma terapia adjuvante utilizada no tratamento de pacientes com epilepsia refratária que não são candidatos à cirurgia ressectiva ou que apresentam resultados limitados após procedimentos cirúrgicos. Atualmente, há evidência suficiente para corroborar seu uso em pacientes com epilepsia focal ou outros tipos de crises epilépticas. Com o intuito de estudar um método para otimizar a terapia através da redução do consumo da bateria do sistema, este projeto teve como objetivo propor uma alteração no protocolo de estimulação já existente, com alteração da frequência de 30 Hz para 20 Hz, através da avaliação de duas variáveis principais: crises convulsivas e efeitos colaterais. A análise prospectiva e duplo-cega consistiu na avaliação por 3 meses de 6 pacientes já submetidos ao implante do VNS, seguida de alteração do parâmetro e continuidade do seguimento por mais 1 mês. Os resultados revelaram que, com a estimulação a 20 Hz, houve 68% de redução da incidência de crises (p = 0,054) assim como baixa incidência de efeitos colaterais (apenas 1 dos 6 pacientes). Por conseguinte, este estudo foi um projeto piloto de curto seguimento, que demonstrou a possibilidade de redução da frequência de estimulação para 20 Hz sem comprometimento da eficácia da terapia ou aumento da taxa de complicações, com consequente aumento da sobrevida do sistema. / Vagus nerve stimulation (VNS) is an adjunctive therapy used to treat patients with refractory epilepsy who are not candidates for resective surgery or have poor results after surgical procedures. There is sufficient evidence nowadays to support its use in patients with focal epilepsy and other seizure types. In order to investigate an approach to optimize therapy and reduce battery consumption, this project aimed at proposing an amendment to the current stimulation protocol, altering it from 30 Hz to 20 Hz, through assessment of two variables: seizures and adverse events. The prospective and double-blind analysis consisted of a 3 month evaluation of 6 patients that had already been implanted with the VNS system, followed by parameter adjustment and follow-up for another month. The results revealed that, with 20 Hz stimulation, there was 68% reduction in seizures (p = 0,054), as well as low incidence of adverse events (only 1 of 6 patients). Therefore, this study was a pilot project with short-term follow-up that indicates the possibility of reducing frequency stimulation to 20 Hz without compromising therapy efficacy and without any increase in complication rates, which could further increase battery life expectancy.

Page generated in 0.2667 seconds