• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 241
  • 201
  • 52
  • 15
  • 11
  • 11
  • 11
  • 11
  • 11
  • 11
  • 11
  • 11
  • 7
  • 6
  • 2
  • Tagged with
  • 625
  • 625
  • 625
  • 625
  • 228
  • 213
  • 177
  • 170
  • 106
  • 100
  • 87
  • 84
  • 69
  • 61
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Validação de métodos para análise de citrato de colina e acetilmetionina em soluções injetáveis por cromatografia líquida de alta eficiência e eletroforese capilar / Validation of methods for analysis of choline citrate and acetylmethionine in injectable solutions by high performance liquid chromatography and capillary electrophoresis.

Alexandre, Grazielle Prado 11 February 2011 (has links)
O objetivo desta pesquisa foi desenvolver, validar e comparar métodos analíticos para separação e quantificação de citrato de colina e acetilmetionina em formulações injetáveis por cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (EC). O método por CLAE, com o qual foi possível quantificar e separar simultaneamente, o citrato de colina e a acetilmetionina, foi realizado empregando-se uma coluna cromatográfica C18, 250 x 4,6 mm, 5µm, Shim-Pack® VP-ODS e fase móvel constituída por tampão fosfato de potássio 25 mM pH 5,7: acetonitrila: metanol (88:10:2 v/v/v). O método por EC foi validado utilizando-se como eletrólito, tampão de tetraborato de sódio 20 mM a pH 9,2 e capilar de sílica fundida de 40,2 cm, sendo 30 cm efetivos, com 75 µm de diâmetro interno. O método por CLAE apresentou um coeficiente de correlação (r) de 0,9996 para o citrato de colina e 0,9998 para a acetilmetionina. No método por EC, o coeficiente de correlação (r) encontrado foi de 0,9996 para a acetilmetionina. Os métodos podem ser considerados eficientes e confiáveis para serem empregados em análises de rotina de controle de qualidade de soluções injetáveis contendo a associação dos dois fármacos selecionados para o estudo. / The objective of this research was to develop, to validate and to compare two analytical methods for separation and quantification of choline citrate and acetylmethionine in injectable formulations by high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). The HPLC method which enables the separation and simultaneous quantitative determination of choline citrate and acetylmethionine was performed using a C18, 250 x 4.6 mm, 5µm-Shim-Pack®VP-ODS column and a mobile phase constituted of buffer 25 mM potassium phosphate, pH 5.7: acetonitrile: methanol (88:10:2 v/v/v). The CE method was validated using a solution of 20 mM sodium tetraborate buffer pH 9.2 as the electrolyte and a fused silica capillary of 40.2 cm, with 30 cm effective, and 75 mm of diameter. The HPLC method showed a correlation coefficient (r) of 0.9996 for choline citrate and 0.9998 for acetylmethionine. For CE method the correlation coefficient (r) was found to be 0.9996 for acetylmethionine. The methods showed to be efficient and reliable methods, and can be used in routine analysis for quality control of injectable solutions containing the association of the two compounds selected to be studied in this research.
262

Determinação simultânea de etinilestradiol e drospirenona em contraceptivos orais por cromatografia e fase líquida de alta eficiência e eletroforese capilar / Simultaneous determination of ethinyl estradiol and drospirenone in oral contraceptive by high performance liquid chromatography and cappilary electrophoresis

Silva, Viviane Benevenuti 13 November 2012 (has links)
O controle da fertilidade é obtido principalmente pela inibição da ovulação por meio da atividade combinada de dois componentes principais: estrogênio e progestina. Desta forma, novas formulações vêm sendo desenvolvidas com baixa dose de etinilestradiol associado a um novo agente progestógeno, a drospirenona, com o objetivo de garantir equilíbrio entre eficácia, segurança e controle de ciclo menstrual. Este trabalho tem como objetivo desenvolver, validar e comparar métodos analíticos para a identificação e quantificação de etinilestardiol e drospirenona presentes em uma mesma formulação por cromatografia em fase líquida de alta eficiência (CLAE) e a eletroforese capilar (EC). O método por CLAE, foi realizado empregando-se uma coluna LiChoCART® 100RP - C18, (125 x 4 mm) 5 µm, fase móvel constituída por MeCN/H2O 50:50 (v/v) e vazão de 1.0 mL min. Utilizou-se um detector UV 200 nm para drospirenona e um de fluorescência λex = 280 nm e λem = 310 nm, para o etinilestradiol. O método por EC foi validado utilizando-se como eletrólito, tampão de tetraborato de sódio 30 mM, dodecil sulfato de sódio 20 mM e acetonitrila 30% a pH 9,2, capilar de sílica fundida de 31,2 cm sendo 21 cm efetivos, com 75 µm de diâmetro interno. O método por CLAE apresentou um coeficiente de correlação (r2) de 0,9989 para o etinilestradiol e 0,999 para a drospirenona. No método por EC, o coeficiente de correlação (r2) encontrado foi de 0,9988 para o etinilestradiol e 0,998 para a drospirenona. Os métodos podem ser considerados eficientes e confiáveis para serem empregados em análise de rotina para controle de qualidade destes produtos farmacêuticos. / The fertility control is achieved mainly by inhibiting ovulation through the combined activity of two main components: estrogen and progestin. Thus, new formulations have been developed associating appropriately low dose of ethinylestradiol to a new drug, the drospirenone, in order to ensure the balance between efficacy, safety and cycle control. The objective of this research was to develop, to validate and to compare two analytical method for separation and quantification of ethinylestardiol and drospirenone using high performance liquid chromatography and capillary electrophoresis (CE). The HPLC method, was performed using a LiChoCART® 100RP - C18, (125 x 4 mm) 5 µm column, a mobile phase constituted of acetonitrile:water (50:50 v/v) and flow rate of 1.0 mL min. UV detection was made for drospirenone at 200 nm coupled with a fluorescence detector at λex= 280 nm and λem = 310 nm for ethinylestradiol. The CE method was validated using a solution of sodium tetraborate buffer 30 mM, sodium dodecil sulphate 20 mM and acetonitrile 30%, pH 9.2 and a fused silica capillary of 31,2 cm with 21 cm effective and 75 µm of diameter. The HPLC method showed a correlation coefficient (r2) of 0.9989 for ethinylestradiol and 0,999 for drospirenone. For CE method, the correlation coefficient was (r2) 0,9988 for ethinylestradiol and 0,9989 for drospirenone. The methods showed to be efficient and reliable, and can be used in routine analysis for quality control of these pharmaceutical preparations.
263

Estudo eletroanalítico e cromatográfico para a análise de LSD em química forense / Electroanalytical and chromatographic studies for determination of LSD in forensic chemistry.

Oiye, Érica Naomi 27 November 2015 (has links)
O LSD, abreviação para a dietilamida do ácido lisérgico, é um alucinógeno que comumente é consumido na forma de selos e suas apreensões são constantes no cenário policial brasileiro e mundial. No momento da apreensão, nos laboratórios forenses tem-se um processo de análises químicas para a confirmação desta droga. As metodologias analíticas precisam ser sensíveis, específicas e fornecer resultados confiáveis, o que o processo de validação através de protocolos normatizados - pode garantir. Neste trabalho, propõem-se procedimentos experimentais para a determinação de LSD em amostras apreendidas através de técnicas de Voltametria Cíclica e Cromatografia Líquida de Alta Eficiência (CLAE) com detecções de arranjo de diodo e eletroquímica. Essas análises permitem ampliar as restritas metodologias encontradas na literatura. Esses procedimentos tiveram o perclorato de amônio em metanol com presença de água como eletrólito de suporte para a detecção voltamétrica, e com base nesses resultados, obteve-se informações para a detecção eletroquímica dentro do sistema cromatográfico. Esta mesma composição de fase móvel também permite a detecção por arranjo de diodo neste sistema. Nos três sistemas estudados, obteve os limites de quantificação de 1,64 10-6 mol L-1, 6,67 10-6 mol L-1 e 3,29 10-6 mol L-1 para as técnivas de Voltametria Cíclica, CLAE com detecção eletroquímica e detecção de arranjo de diodo, respectivamente. Tais valores mostram que as metodologias tem capacidade de analisar baixas concentrações de LSD. Além da validação dos três métodos propostos, fez-se a análise de três amostras apreendidas, das quais uma continha LSD e outras duas não. Deste modo, a partir da combinação dos mesmos componentes de fase móvel, é possível obter dois procedimentos cromatográficos baseados em diferentes tipos de detecção, enquanto que a determinação voltamétrica habilita outro tipo de análise aliando a portabilidade e rapidez da quantificação. Ao fim de todo o processo de validação envolvido, obtêm-se três metodologias que permitem a quantificação de LSD, com a confiabilidade garantida para serem aplicadas em análises de rotina de um laboratório forense. / LSD abbreviation for Lysergic Acid Diethylamide - is a hallucinogenic drug commonly consumed in blotters form. Inside the police scenario, its apprehension is constant in national and global scale. Once the drug is apprehended, forensic laboratories must follow a procedure with chemical analysis aiming a confirmatory result. The analytical methodologies applied for this purposes must be sensitive, specific and provide reliable results, and all these characteristics can be afforded with a validation process behind these procedures. In the present study, three new methodologies for the determination of LSD in seized samples are presented, based on Cyclic Voltammetry technique and High Performance Liquid Chromatography (HPLC) with diode array detection and electrochemical detection. These analyses increase the number of methodologies found in literature for the same purpose. All the experimental procedures included ammonium perchlorate in methanol with the presence of water composing the supporting electrolyte solution for voltammetric measurements. From the electrochemical information observed, it could be applied for electrochemical detection in a chromatographic system. This same composition as mobile phase enables a signal for diode array detection. In all the three systems, the values for limit of quantification were 1.64 10-6 mol L-1, 6.67 10-6 mol L-1 and 3.29 10-6 mol L-1, for voltammetric determination, HPLC with electrochemical detector and diode array detector, respectively. These results prove the methodologies can quantify low concentration of LSD in seized samples. Indeed, after all validation process, three real blotter samples were analyzed, which one of them contained LSD. In this way, from the same components in mobile phase, it is possible to gather two different procedures based on distinct detection principle, whilst the voltammetric determination might be seen as a variety for drug analysis, with portability and quickness as some characteristics for its quantification. Finally, after all validation process applied, there are three methodologies for quantification of LSD in seized samples, with confidence ensured for appliance in the routine of a forensic laboratory.
264

Análise de parabenos em amostras de água de rios e de esgoto sanitário da cidade de São Carlos/SP / Analysis of parabens in water samples from rivers and wastewater in São Carlos city

Derisso, Carolina Resende 07 April 2017 (has links)
A presente pesquisa teve como objetivo desenvolver e validar um método analítico utilizando microextração líquido-líquido (LLME) e cromatografia líquida acoplada ao detector por arranjo de diodos (HPLC-DAD) para análise do metil, etil, propil e butilparabeno em amostras de esgoto sanitário provenientes da Estação de Tratamento de Esgoto de São Carlos (ETE Monjolinho) antes e após o tratamento, bem como em amostras de águas superficiais dos córregos Santa Maria Madalena, Tijuco Preto, Gregório e Monjolinho. Por meio de planejamentos experimentais pode-se desenvolver o método analítico, e inicialmente, otimizou-se as condições cromatográficas, selecionando-se a coluna Zorbax SB-C8 (250 x 4,6 mm, 5 µm), 20 µL de volume de injeção, comprimento de onda de 257 nm, vazão da fase móvel de 1 mLmin-1 e temperatura da coluna cromatográfica de 30°C. A fase móvel com modo de eluição isocrática foi composta por metanol e solução de ácido acético 1% (v/v). No método de extração LLME, o procedimento otimizado utilizou 5 mL de amostra de esgoto, 10 mL de acetato de etila como solvente extrator e 0,4 g de cloreto de sódio (NaCl). Os ensaios de validação demonstraram boa adequação do método desenvolvido, com limites de quantificação de 10 µgL-1 e coeficientes de correlação superiores a 0,99. A recuperação deu-se entre 71 e 99% e a precisão entre 0,4 e 7,4 %, valores estes que estão dentro da faixa de aceite estabelecida pela Agência Nacional de Vigilância Sanitária (ANVISA). Foram realizadas duas coletas em estações diferentes do ano e em ambas foi possível encontrar e quantificar os parabenos. Na primeira coleta, feita em período de estiagem, a concentração encontrada dos parabenos foi maior do que aquela encontrada na segunda coleta. As maiores concentrações encontradas na primeira coleta foram: 0,98 µgL-1 de metilparabeno no esgoto bruto, 9,7 µgL-1 de etilparabeno na amostra de água do rio Monjolinho, 7,9 µgL-1 de propilparabeno na amostra do córrego do Gregório e 11 µgL-1 de butilparabeno no esgoto bruto. Já na segunda coleta, o metilparabeno pode ser quantificado apenas na amostra de esgoto bruto: 0,03 µgL-1 e a maior concentração encontrada de etilparabeno foi de 2,1 µgL-1 no rio do Monjolinho. O butilparabeno foi detectado em seis dos sete pontos amostrados, sendo a maior concentração encontrada no rio do Monjolinho (6,99 µgL-1). O propilparabeno não foi encontrado em nenhuma das amostras da segunda coleta. / The present research had the objective of developing and validating an analytical method using liquid-liquid microextraction (LLME) and liquid chromatography coupled to the detector by diode array (HPLC-DAD) for the analysis of methyl, ethyl, propyl, and butylparaben in wastewater samples from the São Carlos wastewater treatment plant (ETE Monjolinho) before and after treatment; it was also accomplished in surface water samples from Santa Maria Madalena, Tijuco Preto, Gregório, and Monjolinho brooks. By means of experimental planning, the analytical method could be developed, and, initially, the chromatographic conditions were optimized by selecting the Zorbax SB-C8 column (250 x 4,6 mm, 5 μm), injection volume of 20 μL, 257 nm wavelength, mobile phase flow rate of 1 mLmin-1, and chromatographic column temperature at 30ºC. The mobile phase with isocratic elution mode was composed of methanol and 1% (v/v) acetic acid solution. In the LLME extraction method, the optimized procedure used 5 mL of wastewater, 10 mL of ethyl acetate as the extracting solvente, and 0,4 g of sodium chloride (NaCl). The validation tests showed a good fit of the developed method, with quantification limits of 10 μgL-1 and correlation coefficients higher than 0,99. The recovery was between 71% and 99%. Furthemore, the precision was between 0,4% and 7,4%. Those values are within the acceptable range established by the National Agency of Sanitary Administration (ANVISA). Two samplings were carried out in different seasons of the year and, in both, it was possible to find and to quantify the parabens. In the first sampling, during the dry season, the concentration of parabens was higher than that found in the second sampling. The highest concentrations found in the first sampling were: 0,98 μgL-1 of methylparaben in the raw wastewater, 9,7 μgL-1 of ethylparaben in the water sample of Monjolinho river, 7,9 μgL-1 of propylparaben in the water sample of Gregório brook, and 11 μgL-1 in the raw wastewater. In the second sampling, methylparaben could be quantified only in the raw wastewater: 0,03 µgL-1. The highest concentrations of ethylparaben was 2,1 µgL-1 in the Monjolinho river. Butylparaben could be detected in six of seven points, and the highest concentration was in the water sample of Monjolinho river. Propylparaben could not be found in any of the samples.
265

Fungos e micotoxinas em castanhas do brasil, da colheita ao armanezamento. / Fungi and mycotoxins in Brazil nuts, from harvest to storage.

Baquião, Arianne Costa 18 April 2012 (has links)
O trabalho teve como objetivo avaliar a presença de fungos e aflatoxinas e ácido ciclopiazônico (ACP) em castanhas-do-brasil a campo e armazenadas, no solo e ar a fim de estabelecer vias de contaminação fúngica. A pesquisa de fungos foi feita pela técnica de semeadura em superfície em meio Ágar batata dextrose e Ágar Aspergillus flavus parasiticus e a determinação de micotoxinas, por cromatografia líquida de alta eficiência. As amostras a campo foram analisadas em: Dia 0; amostras na árvore, Dias 5, 10 e 15; em contato com solo 5, 10 e 15 dias, respectivamente. As armazenadas foram analisadas mensalmente por 11 meses. A campo, os fungos mais prevalentes foram: A. flavus em ouriços e amêndoas; Fusarium spp. em cascas. No solo foram isolados Penicillium spp. e Aspergillus flavus e no ar, Fusarium spp. e Penicillium spp. No armazenamento, em amêndoas, foi constatado A. flavus, Fusarium spp. e A. nomius; e em cascas, Fusarium spp. e A. flavus. Aflatoxinas e ACP não foram detectados. O aumento do tempo de contato das castanhas-do-brasil com o solo foi acompanhado de maior isolamento de A. flavus; sugerindo contaminação da castanha durante etapa a campo. A. nomius e A. parasiticus foram isolados apenas no armazenamento, indicando contaminação no estoque das amêndoas. / The objective of this present study was analyse, in the field and in the storage, mycobiota and the contamination by (aflatoxins and cyclopiazonic acid from Brazil nuts, soil and air samples to determine route of fungi contamination. The Brazil nuts mycobiota was determine by diluition plating method in Potate Dextrose Agar and Aspergillus flavus parasiticus agar and, micotoxins was done by high performance liquid chromatography. Field samples were collected in: day 0, samples still on the tree; days 5, 10 and 15, samples in contact with soil for 5, 10 and 15 days, respectively. The most prevalent fungi were Aspergillus flavus in fruit pods and nuts and Fusarium spp. in shells. Penicillium spp. and A. flavus were isolated from soil, and Fusarium spp. and Penicillium spp. from air. The storage samples were analysed montly during 11 months; and showed predominance A. flavus, Fusarium spp. e A. nomius in nuts, and Fusarium spp. and A. flavus in shells. Aflatoxins and cyclopiazonic acid were not detected. These findings indicate soil as the main source of fungal contamination of Brazil nuts. A. nomius e A. parasiticus were isolated only in storage, suggesting Brazil nuts contamination occurs in this period.
266

Avaliação da extração de hemicelulose e da produção de xilooligossacarídeos a partir de um subproduto de Eucalyptus oriundo de uma empresa de celulose /

Mafei, Thamyres Del Torto. January 2017 (has links)
Orientador: Fernando Masarin / Banca: Michel Brienzo / Banca: Guilherme Peixoto / Resumo: A madeira de Eucalyptus é aplicada principalmente na cogeração de energia, na alimentação animal, na produção de carvão vegetal e na produção de celulose. Um subproduto de Eucalyptus gerado em fábricas de celulose é utilizado principalmente para cogeração de energia, porém o mesmo apresenta um grande potencial a ser estudado, pois tem um elevado teor de celulose e hemicelulose. Uma alternativa é a produção de xilooligossacaródeos (XOS) a partir do subproduto de Eucalyptus. Os XOS são responsáveis por diversos efeitos benéficos como a prevenção de cáries, a diminuição de níveis séricos de colesterol e o estímulo do crescimento de bifidobactérias no trato gastrointestinal. Objetivo: O presente trabalho propôs avaliar a produção de XOS via hidrólise enzimática de um subproduto de Eucalyptus oriundo de uma empresa de celulose. Métodos: A parte experimental envolveu a obtenção de um subproduto de Eucalyptus oriundo do processamento de toras de madeira. O subproduto foi moído e extraído com etanol e posteriormente pré-tratado com clorito de sódio. Os subprodutos, extraído (SE) e extraído e pré tratado (SEP), foram submetidos a um processo de extração de hemicelulose. As hemiceluloses, hemicelulose extraído do subproduto extraído-moido (HSE) e hemicelulose extraído do subproduto extraído e pré-tratado (HSEP) e os subprodutos (SE e SEP) foram caracterizados quimicamente em relação aos teores de celulose, hemicelulose e lignina. Além disso, as hemiceluloses obtidas (HSE e HSEP) e os s... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Eucalyptus wood is mainly applied to energy cogeneration production, animal feed, charcoal production and pulp production. A byproduct of Eucalyptus generated in pulp mills is mainly used for energy cogeneration, but it has a great potential to be studied because it has a high content of cellulose and hemicellulose. An alternative is the production of XOS from the Eucalyptus byproduct. The XOS are responsible for several beneficial effects such as caries prevention, decreased serum cholesterol levels and stimulation of the growth of bifidobacteria in the gastrointestinal tract. Objective: The present work proposed to evaluate the XOS production through enzymatic hydrolysis of a by-product of Eucalyptus from a cellulose company. Methods: The experimental part involved the obtaining of a by-product of Eucalyptus from the processing of wood logs. The by-product was ground and extracted with ethanol and then pretreated with sodium chlorite. The by-products, extracted (SE) and extracted and pre-treated (SEP), were submitted to a hemicellulose extraction process. Hemicelluloses, hemicellulose extracted from the groundextracted by-product (HSE) and hemicellulose extracted from the pre-treated by-product (HSEP) and by-products (SE and SEP) were chemically characterized in relation to the contents of cellulose, hemicellulose and lignina. In addition, the obtained hemicelluloses (HSE and HSEP) and by-products (SE and SEP) were enzymatically hydrolyzed using the commercial extracts Cellulase (Sigma), Celluclast (Novozymes) and Xilanases (Verdartis) to evaluate to evaluate the production of XOS.Results: SE and SEP presented cellulose... (Complete abstract click electronic access below) / Mestre
267

Relação entre hábito alimentar e síndrome do espectro autista / Relationship between food habits and autistic spectrum

Silva, Nádia Isaac da 14 March 2011 (has links)
O autismo é uma síndrome que afeta todas as áreas do comportamento humano. Sua etiologia não está definida. Os estudos descreveram uma associação do autismo com diversas anormalidades fisiológicas entre elas, distúrbios relacionados ao metabolismo proteico. A teoria do excesso de peptídeos opioides afirma que o consumo de glúten e caseína pode intensificar o comportamento da síndrome do espectro autista. Outra hipótese é de que distúrbios do metabolismo da creatina também estão integrados à doença. Os objetivos desse estudo foram: avaliar a variedade e a frequência de alimentos consumidos por autistas, bem como a adequação desse consumo; avaliar as alterações do metabolismo da creatina; desenvolver testes preliminares para determinar as condições mais adequadas para a identificação e possível quantificação dos peptídeos opioides derivados do glúten e da caseína por HPLC. Para atingir esses objetivos foi elaborada uma anamnese nutricional, contendo questões sobre características sócio-demográficas das famílias dos autistas participantes, histórico pessoal de doenças, comportamento autista durante as refeições, e levantamento de hábito alimentar. Para caracterizar o quadro clínico da população foi realizada uma avaliação psicológica com aplicação do método quantitativo Childhood Autism Rating Scale (CARS) e a identificação de presença de retardo mental foi através de levantamento de avaliação clínica existente, feita por equipe multidisciplinar das instituições participantes. A concentração de creatinina na urina dos autistas e grupo controle formado por parentes do mesmo sexo foi determinada pelo método de Jaffé. Os resultados sobre a caracterização da população indicaram que 1/3 dos pais de autistas possuem baixa escolaridade e 60% renda familiar na faixa de 2 a 4 salários mínimos. Segundo o método de avaliação CARS 64% dos autistas são casos graves. A renite alérgica é a patologia de maior prevalência na população estudada. Em média 60,71% dos autistas apresentam sintomas gástricos, sendo o mais frequente a flatulência (39,90%). O registro sobre comportamento alimentar identificou que 50% dos autistas expressam o comportamento de comerem muito rápido e 46,43% consomem porções exageradas de alimentos. Esse fato influência diretamente o hábito alimentar. A avaliação de adequação de consumo de nutrientes revelou que 57,14% têm o consumo de energia superior ao recomendado e baixo consumo de fibras, ácido ascórbico e cálcio. As análises de concentração de creatinina revelaram que os valores são significativamente inferiores em crianças autistas e do grupo controle formado por parentes distantes e que são similares quando comparado com grupo formado por seus pais. As análises iniciais por cromatografia líquida de alta performance evidenciam que dos dois métodos desenvolvidos o codificado como número 2 é mais eficiente do que o número 1, pois consegue distinguir os picos de todos os padrões de peptídeos testados e que o protocolo inicial para a extração de peptídeos opioides em fase sólida deve ser revisto. / Autism is a syndrome that affects all areas of human behavior. Its etiology is not defined. The studies described an association of autism with various abnormalities including physiological disorders related to protein metabolism. The theory of excess opioid peptides says that consumption of gluten and casein can intensify the behavior of autistic spectrum syndrome. Another hypothesis is that disorders of creatine metabolism are also integrated to the disease. The objectives of this study were to assess the variety and frequency of foods consumed by autism, as well as the appropriateness of this consumption and to evaluate the changes of creatine metabolism, developing preliminary tests to determine the most appropriate conditions for the identification and possible quantification of opioid peptides derived from gluten and casein by HPLC. To achieve these objectives was drawn up a nutritional interview containing questions on sociodemographic characteristics of the families of autistic participants, personal history of disease, autistic behavior during meals, and a survey of eating habits. To characterize the clinical status of the population a psychological evaluation was performed using a quantitative Childhood Autism Rating Scale (CARS). The creatinine concentrations in urine of autistic and control group formed by relatives of the same sex was determined by the Jaffé. The results on the characterization of the population indicated that one third of parents of autistic children have lower education and 60% of family income in the range from 2 to 4 minimum wages. According to the method of evaluation CARS 64% of autistic children are severe cases. The allergic rhinitis is the most prevalent disease in this population. On average 60.71% of people with autism have gastric symptoms, the most frequent flatulence (39.90%). The record on eating behavior found that 50% of autistic children express the behavior of eating too fast, and 46.43% consume excessive portions of food. This fact directly influences the food habits. The assessment of adequacy of nutrient intake have revealed that 57.14% of energy consumption and lower than the recommended intake of fiber, and calcium acid ascorbic. The analysis revealed that creatinine concentration values are significantly lower in autistic children and the control group formed by distant relatives and are compared with similar group formed by his parents. Initial analysis by high performance liquid chromatography showed that the two methods developed and coded as number 2 is more efficient than a number, for it can distinguish the peaks of all patterns of peptides tested and that the initial protocol for the extraction of opioid peptides in the solid phase should be reviewed.
268

Análise de parabenos em amostras de água de rios e de esgoto sanitário da cidade de São Carlos/SP / Analysis of parabens in water samples from rivers and wastewater in São Carlos city

Carolina Resende Derisso 07 April 2017 (has links)
A presente pesquisa teve como objetivo desenvolver e validar um método analítico utilizando microextração líquido-líquido (LLME) e cromatografia líquida acoplada ao detector por arranjo de diodos (HPLC-DAD) para análise do metil, etil, propil e butilparabeno em amostras de esgoto sanitário provenientes da Estação de Tratamento de Esgoto de São Carlos (ETE Monjolinho) antes e após o tratamento, bem como em amostras de águas superficiais dos córregos Santa Maria Madalena, Tijuco Preto, Gregório e Monjolinho. Por meio de planejamentos experimentais pode-se desenvolver o método analítico, e inicialmente, otimizou-se as condições cromatográficas, selecionando-se a coluna Zorbax SB-C8 (250 x 4,6 mm, 5 µm), 20 µL de volume de injeção, comprimento de onda de 257 nm, vazão da fase móvel de 1 mLmin-1 e temperatura da coluna cromatográfica de 30°C. A fase móvel com modo de eluição isocrática foi composta por metanol e solução de ácido acético 1% (v/v). No método de extração LLME, o procedimento otimizado utilizou 5 mL de amostra de esgoto, 10 mL de acetato de etila como solvente extrator e 0,4 g de cloreto de sódio (NaCl). Os ensaios de validação demonstraram boa adequação do método desenvolvido, com limites de quantificação de 10 µgL-1 e coeficientes de correlação superiores a 0,99. A recuperação deu-se entre 71 e 99% e a precisão entre 0,4 e 7,4 %, valores estes que estão dentro da faixa de aceite estabelecida pela Agência Nacional de Vigilância Sanitária (ANVISA). Foram realizadas duas coletas em estações diferentes do ano e em ambas foi possível encontrar e quantificar os parabenos. Na primeira coleta, feita em período de estiagem, a concentração encontrada dos parabenos foi maior do que aquela encontrada na segunda coleta. As maiores concentrações encontradas na primeira coleta foram: 0,98 µgL-1 de metilparabeno no esgoto bruto, 9,7 µgL-1 de etilparabeno na amostra de água do rio Monjolinho, 7,9 µgL-1 de propilparabeno na amostra do córrego do Gregório e 11 µgL-1 de butilparabeno no esgoto bruto. Já na segunda coleta, o metilparabeno pode ser quantificado apenas na amostra de esgoto bruto: 0,03 µgL-1 e a maior concentração encontrada de etilparabeno foi de 2,1 µgL-1 no rio do Monjolinho. O butilparabeno foi detectado em seis dos sete pontos amostrados, sendo a maior concentração encontrada no rio do Monjolinho (6,99 µgL-1). O propilparabeno não foi encontrado em nenhuma das amostras da segunda coleta. / The present research had the objective of developing and validating an analytical method using liquid-liquid microextraction (LLME) and liquid chromatography coupled to the detector by diode array (HPLC-DAD) for the analysis of methyl, ethyl, propyl, and butylparaben in wastewater samples from the São Carlos wastewater treatment plant (ETE Monjolinho) before and after treatment; it was also accomplished in surface water samples from Santa Maria Madalena, Tijuco Preto, Gregório, and Monjolinho brooks. By means of experimental planning, the analytical method could be developed, and, initially, the chromatographic conditions were optimized by selecting the Zorbax SB-C8 column (250 x 4,6 mm, 5 μm), injection volume of 20 μL, 257 nm wavelength, mobile phase flow rate of 1 mLmin-1, and chromatographic column temperature at 30ºC. The mobile phase with isocratic elution mode was composed of methanol and 1% (v/v) acetic acid solution. In the LLME extraction method, the optimized procedure used 5 mL of wastewater, 10 mL of ethyl acetate as the extracting solvente, and 0,4 g of sodium chloride (NaCl). The validation tests showed a good fit of the developed method, with quantification limits of 10 μgL-1 and correlation coefficients higher than 0,99. The recovery was between 71% and 99%. Furthemore, the precision was between 0,4% and 7,4%. Those values are within the acceptable range established by the National Agency of Sanitary Administration (ANVISA). Two samplings were carried out in different seasons of the year and, in both, it was possible to find and to quantify the parabens. In the first sampling, during the dry season, the concentration of parabens was higher than that found in the second sampling. The highest concentrations found in the first sampling were: 0,98 μgL-1 of methylparaben in the raw wastewater, 9,7 μgL-1 of ethylparaben in the water sample of Monjolinho river, 7,9 μgL-1 of propylparaben in the water sample of Gregório brook, and 11 μgL-1 in the raw wastewater. In the second sampling, methylparaben could be quantified only in the raw wastewater: 0,03 µgL-1. The highest concentrations of ethylparaben was 2,1 µgL-1 in the Monjolinho river. Butylparaben could be detected in six of seven points, and the highest concentration was in the water sample of Monjolinho river. Propylparaben could not be found in any of the samples.
269

Desenvolvimento e validação de método analítico para análise de parabenos em tecido de peixes / Development and validation of the analytical method for analysis of parabens in fish tissue

Gabriela Lemos de Oliveira Ribeiro 11 December 2014 (has links)
O presente estudo teve como objetivo desenvolver e validar um método analítico para a investigação de parabenos em tecido de peixe. Para o preparo de amostra empregou-se como método a microextração líquido-líquido (LLME) seguido de análise cromatográfica líquida de alta eficiência acoplada a um detector de arranjo de diodos. Empregou-se coluna Nucleodur C8 (4,6 x 250 mm, 5 µm), com injeção de 20µL, fluxo de 1mL min-1, temperatura de 25 °C, comprimento de onda 258nm e fase móvel composta por água acidificada com 1% de ácido acético e metanol em modo gradiente na proporção de 60% de metanol até 8 minutos e de 65% até 20 minutos. A recuperação do método para o metilparabeno nas concentrações 0,05; 0,1; 0,25; 0,5; 0,8 e 1,0 µgg-1 foi de 94; 95; 89; 83; 100 e 74% respectivamente e o desvio padrão relativo foi de 7,0; 0,5; 3,2; 10,0; 5,2 e 2,9 %para as seis concentrações. A recuperação do etilparabeno foi de 107; 103; 80; 89; 89 e 88% para as seguintes concentrações 0,05; 0,1; 0,25; 0,5; 0,8 e 1,0 µgg-1 e o desvio padrão foi de 7,4; 4,1; 12,2; 3,2; 7,7 e 3,6 % respectivamente. A recuperação do propilparabeno foi de 106; 96; 94; 97; 100 e 76 % para as seguintes concentrações 0,05; 0,1; 0,25; 0,5; 0,8 e 1,0 µgg-1 e o desvio padrão foi de 14,2; 8,6; 14,9; 4,0; 7,9 e 2,6 % respectivamente. A recuperação do butilparabeno foi de 102; 74; 96; 79; 112 e 78% para as seguintes concentrações 0,05; 0,1; 0,25; 0,5; 0,8 e 1,0 µgg-1 e o desvio padrão foi de 7,7; 4,0; 9,1; 5,5; 2,0 e 4,2 % respectivamente. Os limites de detecção variaram de 0,0007 a 0,0221 µgL-1 e os de quantificação de 0,0021 a 0,0738 µgL-1. Os coeficientes de correlação ficaram entre 0,9837 a 0,9906 dentro do limite estabelecido pela Agência Nacional de Vigilância Sanitária para matrizes biológicas. O método foi aplicado em três amostra de peixes adquiridos no comércio de São Carlos - SP. Em 50% das amostras analisadas encontrou-se picos cromatográficos nos mesmos tempos de retenção dos padrões dos parabenos. A concentração do etilparabeno foi de 0,0438 µgg-1, para o propilparabeno a concentração foi de 0,0365 a 0,0564 µgg-1 e para o butilparabeno a concentração foi de 0,0322 a 0,0678 µgg-1. O metilparabeno foi o único que não foi encontrado nas amostras de tecido dos peixes analisadas. / his research aimed to develop and validate a new chromatographic method combined with liquid-liquid microextraction (LLME) for the determination and quantification of parabens in fish tissue. A high performance liquid chromatography coupled with diode array detection was employed with a Nucleodur C8 ec column (250 x 4.6 mm, 5 µm), injection volume of 20?L, wavelength of 258nm, flow rate of 1 mL min-1, temperature of 25 ° C and gradient mode, using 1% of acetic acid diluted in water and methanol, in the proportion of 60% of methanol until 8 minutes and 65% within 20 minutes. The liquid-liquid microextraction (LLME) provided adequate recoveries of 94; 95; 89; 83; 100 and 74% for the methylparaben at concentration of 0,05; 0,1; 0,25; 0,5; 0,8; 1,0 µgg-1 respectively, with accuracy of 7,0; 0,5; 3,2; 10,0; 5,2 and 2,9 %. The recoveries for the ethylparaben was 107; 103; 80; 89; 89 and 88% at concentration of 0,05; 0,1; 0,25; 0,5; 0,8 and 1,0 µgg-1 respectively,with accuracy of 7,4; 4,1; 12,2; 3,2; 7,7 and 3,6 % The recoveries for the propylparaben was 106; 96; 94; 97; 100 and 76 % at concentration of 0,05; 0,1; 0,25; 0,5; 0,8; 1,0 µgg-1 respectively, with accuracy of 14,2; 8,6; 14,9; 4,0; 7,9 and 2,6 % . The recoveries for the butylparaben was 102; 74; 96; 79; 112 and 78%at concentration of 0,05; 0,1; 0,25; 0,5; 0,8; 1,0 µgg-1 respectively,with accuracy of 7,7; 4,0; 9,1; 5,5; 2,0 and 4,2 %. The method detection limits (MDLs) ranged from 0,0007 a 0,0221 µgL-1 and the method quatification limists (MQLs) ranged from 0,0021 a 0,0738 µgL-1. The correlation coefficients ranged from 0.9837 to 0.9906 not further than the limits established by the Agência Nacional de Vigilância Sanitária for complex samples. The method LLME/HPLC-DAD was applied to the analysis of three samples from the market of São Carlos-SP. In 50% of the samples analysed, chromatographic peaks were found at the same retention times of parabens. The ethylparaben concentrations founded was 0,0438 µgg-1, for propylparaben concentration ranged from 0,0365 to 0,0564 µgg-1 and for butylparaben concentration ranged from 0,0322 to 0,0678 µgg-1. The methylparaben was not found in the fish tissue sample analyzed.
270

Determinação de ácido ascórbico por técnicas eletroquímicas e cromatográficas. Uma comparação estatística de desempenho. / Ascorbic Acid determination by electrochemical and chromatographic techniques. A statistical comparison of performance.

Pollyana Ferreira da Silva 16 October 2015 (has links)
As técnicas de voltametria de pulso diferencial e de cromatografia líquida de alta eficiência foram utilizadas para a detecção do ácido ascórbico (AA) em amostras farmacêuticas. O eletrodo de carbono vítreo modificado com nanopartículas de antimônio ancoradas em nanotubos de carbono de paredes múltiplas foi utilizado para a determinação eletroanalítica de ácido ascórbico. Parâmetros como eletrólito suporte, volume adicionado do nanocompósito à superfície do eletrodo, pH do eletrólito, amplitude e incremento de potencial foram avaliados e definidos os que obtiveram os melhores resultados. A curva analítica obtida para a determinação de AA com concentrações entre 291-698 µmol L-1 em comprimidos pelo método eletroanalítico apresentou boa linearidade (0,998) e limites de detecção e quantificação 42,58 µmol L-1 e 25,00 µmg L-1, respectivamente. O método cromatográfico utilizado foi validado e a curva analítica obtida para a determinação de AA com concentrações entre 291-698 µmol L-1 em comprimidos através desse método apresentou boa linearidade (0,998) e limites de detecção e quantificação 37,24 µmol L-1 e 21,86 µmg L-1, respectivamente. Os resultados obtidos foram validados comparados estatisticamente pelo método de regressão linear descrito por Miller e Miller. Para avaliar a equivalência entre os métodos utilizou-se um teste t de Student pareado, que confirmou a equivalência dos métodos estudados para esta aplicação. / Techniques of differential pulse voltammetry and high-performance liquid chromatography were used for detection of ascorbic acid (AA) in pharmaceutical samples. The glassy carbon electrode modified with antimony nanoparticles anchored in multi-walled carbon nanotubes was used for electroanalytical determination of ascorbic acid. Parameters as supporting electrolyte, the volume of nanocomposite added to the electrode surface, pH of the electrolyte, amplitude and step potential were evaluated and defined. The calibration curve obtained by electroanalytical method for determination of AA with concentrations between 291-698 µmol L-1 using pills, showed good linearity (0.998) and limits of detection and quantification 42,58 µmol L-1 e 25,00 µmg L-1, respectively. The chromatographic method used was validated and the analytical curve obtained for determination of AA with concentrations between 291-698 µmol L-1 using pills showed good linearity (0.998) and limits of detection and quantification 37,24 µmol L-1 and 21,86 µmg L-1, respectively. The results were validated and statistically compared by the linear regression method described by Miller and Miller. To evaluate the equivalence between the methods, Student\'s paired t-test was used, which confirmed the equivalence of the methods studied for this application.

Page generated in 0.1026 seconds