61 |
Energikartläggning av hotellbyggnad med byggår 2016 och effektivisering av ventilation i IDA-ICE / Energy evaluation of hotel building built 2016 and energy efficiency of ventilation in IDA-ICEForslund, August January 2020 (has links)
The main purpose of this thesis was to evaluate the energy use and the potential for energy savings in the ventilation for a hotel building that has been preliminary certified in the Swedish environmental assessment method Miljöbyggnad. In the preliminary certificate the building received the certificate SILVER for the energy use. This certificate needs to be verified in order to acquire the final certificate. The energy use was determined with data from energy meters and statistics from the energy provider. The potential for energy savings in the ventilation was evaluated by analyzing the effects of air flows, room temperature and supply temperature on the energy use and the room climate with the help of the simulation program IDA-ICE. The results show that the energy use in the building is 119 kWh/(m2, year), which equals the certificate BRONS in Miljöbyggnad. The certificate for SILVER will not be achieved. The biggest energy consumers are the heating system, the hot water system and the cooling system. They stand for 36, 21 and 19 percent of the total energy use, respectively. With energy savings measures in the ventilation the energy use can be reduced by 8 kWh/(m2, year). This would mean that the energy use can be reduced to 110 kWh/(m2, year). The building would still receive the certificate for BRONS. The energy savings, however, would be achieved by using a lower supply temperature, minimum air flows (0,1 l/(s, m2)) when rooms are not used as well as decreasing the time schedule for the ventilation by two hours and allowing the maximum temperature to rise by 0,5 degrees Celsius. This also resulted in a higher temperature in the conference rooms, where the temperature could reach up to 24,2 degrees Celsius in winter and 24,5 degrees Celsius hot summer days.
|
62 |
Analys av felkällor vid energisimuleringar : En jämförelse mellan IDA ICE och CFDPersson, Therese January 2013 (has links)
I detta arbete har energisimuleringsprogrammet IDA ICE utvärderats genom att simuleringar gjorda i detta program jämförts med simuleringar gjorda i CFD-programmet ANSYS Fluent. Modeller i form av ett kvadratiskt kontorsrum med fönster ställdes upp för ett basfall i de båda programmen och parametern operativ temperatur jämfördes. För att se hur förändringar i modellerna påverkade resultatet ställdes ett antal nya fall upp där olika parametrar varierades. Variablerna som en i taget ändrades vid uppställningar av nya simuleringsfall var: rumshöjd, U-värde på fönstret, deplacerande istället för omblandande ventilation, radiator istället för golvvärme, tilluftstemperatur, mätpunktens placering samt hur till-och frånluftsdonen placerades. Resultatet av simuleringarna visade att den operativa temperaturen höll sig på en relativt konstant nivå för de olika fallen i IDA ICE, medan värdet på denna parameter varierade för de olika fallen vid CFD-simuleringarna. Slutsatsen som dras av detta är att IDA ICE är bra för generella beräkningar av operativ temperatur och termisk komfort, men att denna parameter inte bör användas vid optimering av systemet i IDA ICE eftersom programmet inte tar hänsyn till luftrörelser och hur don är placerade.
|
63 |
Pluginkonfigurering - ett grafiskt och användarvänligt sätt att konfigurera "plugins" i iipax / Plugin Configuration- a graphical and user-friendly way to configure the plugins in iipaxvon Weber, Ludwig January 2012 (has links)
Företaget Ida Infront, där examensarbetet utfördes, var intresserad av hur den grafiska pluginkonfigurering kan göras mer användarvänlig i deras egenproducerade mjukvaruprogram iipax. Programmet iipax används bland annat till att effektivisera ärendehanteringsprocesser och digitala arkiveringar. Det är till stor del uppbyggt av plugins vilka förtecknas i en konfigurationsfil men även i vissa fall det grafiska användargränssnittet. Pluginkonfigurering sker genom att användaren fyller i pluginnamn, parameternamn och parametervärden för ett plugin i ett formulär. Det finns ingen information i programmet vilka plugins som finns eller vad de har för parametrar, vilket gör det svårt att konfigurera plugins. Utifrån en kravspe-cifikation som angavs i början av examensarbetet och möten med anställda på Ida Infront har en prototyp tagits fram som visar hur man kan konfigu-rera plugins på ett enklare sätt. Prototypen är ett modifierat iipax-program där ett ramverk, som består av en databas med plugins och en grafisk konfigureringskomponent, ingår. Ramverket använder "reflection" för att hitta plugins, vilket gör att bara plugins som existerar på servern kan läggas till i databasen. I konfigureringskomponenten kan användaren välja plugins från en lista och pluginparametrarna fylls i och valideras automatiskt. Det undersöktes även hur annotationer kan användas för att förbättra möjlighe-terna att samla in information om plugins. I prototypen krävs inte samma förkunskap av användaren för att konfigurera plugins som i ett omodifierat iipax och risken att användaren gör fel har minskats. Enligt min uppfatt-ning har pluginkonfigureringen blivit användarvänligare, men det har inte utförts någon undersökning för att bekräfta detta. / The company Ida Infront, where the thesis was performed, was interested in how plugin configuration can be made more user-friendly in their self-produced software application iipax. The program iipax is used, among other things, to streamline workflow processes and digital archives. It is largely made up of plugins listed in a configuration file, but in some cases also in the graphical user interface. Plugin configuration is done by the user who fills in the plugin name, parameter names and parameter values into a form. There is no information available in the program about which plugins exist or what parameters they have, making it difficult to configure the plugins. Based on a specification given in the beginning of the thesis work and on meetings with employees at Ida Infront, a prototype has been developed that shows how configuring plugins in a simpler way is done. The prototype is a modified iipax application in which a framework, consisting of a database with plugins and a graphic configuration component, is included. The framework uses "reflection" to locate plugins, which means that only plugins that exist on the server can be added to the database. In the configuration component, the user can choose a plugin from a list and plugin parameters are filled in and validated automatically. It was also examined how annotations can be used to improve the ability to collect information about plugins. The prototype does not require the prior knowledge of the user to configure the plugins in an unmodified iipax and the risk that the user make an error has been reduced. In my opinion configuring plugins has been made more user-friendly, but no research has been done to confirm this.
|
64 |
Byggnadsutformningens påverkan på den specifika energianvändningen / The impact of building design on the specifik energy useKarerwa, Eddy Sage January 2021 (has links)
Examensarbetets syfte var att undersöka hur en byggnadsutformning påverkar den specifika energianvändningen. Det gjordes genom att simulera olika modeller av en förskola i IDA ICE. Underlaget för studien var förskolan Teleskopet som befann sig i stadsdelen Tavleliden i Umeå som illustrerades av modeller i IDA ICE för att sedan göra energibalansberäkningar. Fyra modeller med olika formfaktorer byggdes i IDA ICE. Ett enplanshus, ett tvåplanshus, ett treplanshus och ett fyrplanshus simulerades för att sedan bestämma hur formfaktor i förhållande till den specifika energianvändningen varierade. Modellerna som simulerades i IDA ICE behövde ha identiska brukarindata för att bara formfaktor skulle ändras. Således användes Boverkets föreskrifter om ändring av verkets föreskrifter och allmänna råd (2016:12) om fastställande av byggnadens energianvändning vid normalt brukande och ett normalår(BEN 2),Boverkets föreskrifter om ändring i boverkets byggregler (2011:6) -föreskrifter och allmänna råd; bfs 2020:4(BBR 29) och Umeå tekniska anvisningar från Umeå Kommun fastighet. Generellt sett visade det sig att enplanshus hade högre formfaktor jämfört med de andra modellerna. Studien visade att från en formfaktor på 2.4 till en formfaktor på 0.9 minskade den specifika energianvändningen med 4.9[ kWh/m2,år ]. Från samma studie kunde man också visa att om man ökade persontätheten från [ 0.33pers/m2,Atemp ] till [ 0.5pers/m2,Atemp ] kunde man spara 5.3[ kWh/m2,år ] på den specifika energianvändningen. Sammanfattningsvis är val av byggnadsutformning och persontäthet viktigt för att avgöra energiprestanda på byggnaden. Studien visar att ju lägre formfaktor samt högre persontätheten i en och samma byggnad påverkar byggnadens energianvändning med en total minskning på 5.3[ kWh/m2,år ]. / The purpose of the thesis project was to investigate how a building design affects it specific energy use. This was done by simulating different models of one preschool in IDA ICE. The basis for the study was the preschool Teleskopet which was located in the district Tavleliden in Umeå which was illustrated by models in IDA ICE and then make energy balance calculations.Four models with different form factors were built in IDA ICE. A single-storey house, a two-storey house, a three-storey house and a four-storey house were simulated to then determine the form factor in relation to the specific energy use varied. The models simulated in IDA ICE needed to have identical user data so that the form factor would change.The National Board of Housing, Building and Planning’s regulations on changing the board of directors were used, regulations and general guidelines (2016: 12) on the determination of the building energy use during normal use and a normal year (BEN 2), the National Board of Housing, Building and Planning’s regulations on changes in the National Board of Housing, Building and Planning’s building regulations (2011: 6) regulations and general guidelines; bfs 2020: 4 (BBR 29) and Umeå technical instructions from Umeå Municipality property were taken into consideration.In general, it turned out that single-storey houses had a higher form factor compared to those other models.The study showed that from a form factor of 2.4 to a form factor of0.9 it reduced the specific energy consumption by 4.9[ kWh/m2,year ]. The same study also showed that if one increased the person density from [ 0.33pers/m2,Atemp ] to [ 0.5pers/m2,Atemp ] resulted in a decrease of 5.3[ kWh/m2,year ] on the specific energy use. In conclusion,the choice of building design and person density is important to determine the energy performance of the building. The study showed that the lower the form factor and the higher the density of persons in one and the same building were, had an effect on the building’s energy use by one total reduction of 5.3 [ kWh/m2,year].
|
65 |
Klimatanpassning av en skolbyggnad : Genom simuleringar utifrån framtidens klimatförändringarSammeli, Matilda January 2022 (has links)
The aim of this thesis was to examine what impact future climate change and raised temperatures will have on current building design and how they can be adapted to the future climate change in terms of energy use, indoor temperature and thermal comfort by using passive solutions. This was carried out by a case study of a school building located in the Uppsala- Stockholm area, which was modeled in the energy simulation tool IDA ICE 4.8. The building was then compared in today’s (2020) climate to the future (2080) climate based on future weather data representing IPCCS’s RCP 8,5 scenario for the year of 2080, followed by an assessment of several climate adaption measures in the future climate. The result showed a future climate much warmer than the one today, with a monthly average temperature up to 1,5 degrees higher. This led to the school building being overheated for 703 hours during the period of April-September in the future climate, in comparison to 20 hours in today’s climate, regarding mean air temperature. The energy usage of the building showed a smaller heat demand for the 2080 climate but an added cooling demand that did not exist in the 2020 climate. Despite the added cooling demand, the building had a lower energy usage in total in the future climate. In order to adapt the building to the 2080 climate, 10 passive measures were simulated individually as well as combined into two different packages of solutions, one large and one small. Overall, the results showed that no measure or package was enough to adapt the building in order to reach the current indoor climate requirements. For the building to keep the maximum mean air temperature at 26 degrees, an active cooling was needed as well. The measure keeping the lowest indoor temperature was the large package of solutions. Although, knowing that passive measures were not enough for the building to reach the current thermal requirements, looking at the total energy usage showed that the smaller package of solutions had the lowest annual energy demand of all measures. It had a marginally higher cooling demand due to fewer measures, but a significantly lower heating demand due to a less effective solar protection and a higher internal heating load.
|
66 |
Byggnadsutformningens påverkan på den specifika energianvändningen / The impact of building design on the specific energy useKarerwa, Eddy Sage January 2021 (has links)
Examensarbetets syfte var att undersöka hur en byggnadsutformning påverkar den specifika energianvändningen. Det gjordes genom att simulera olika modeller av en förskola i IDA ICE. Underlaget för studien var förskolan Teleskopet som befann sig i stadsdelen Tavleliden i Umeå som illustrerades av modeller i IDA ICE för att sedan göra energibalansberäkningar. Fyra modeller med olika formfaktorer byggdes i IDA ICE. Ett enplanshus, ett tvåplanshus, ett treplanshus och ett fyrplanshus simulerades för att sedan bestämma hur formfaktor i förhållande till den specifika energianvändningen varierade. Modellerna som simulerades i IDA ICE behövde ha identiska brukarindata för att bara formfaktor skulle ändras. Således användes Boverkets föreskrifter om ändring av verkets föreskrifteroch allmänna råd (2016:12) om fastställande av byggnadens energianvändning vid normalt brukande och ett normalår(BEN 2),Boverkets föreskrifter om ändring i boverkets byggregler (2011:6) -föreskrifter och allmänna råd; bfs 2020:4(BBR 29) och Umeå tekniska anvisningar från Umeå Kommun fastighet. Generellt sett visade det sig att enplanshus hade högre formfaktor jämfört med de andra modellerna. Studien visade att från en formfaktor på 2.4 till en formfaktor på 0.9 minskade den specifika energianvändningen med 4.9[kWh/ m2 ,år]. Från samma studie kunde man också visa att om man ökade persontätheten från [0.33 pers/m2 ,Atemp] till [0.55 pers/m2 ,Atemp] kunde man spara 5.3[kWh/ m2 ,år] på den specifika energianvändningen. Sammanfattningsvis är val av byggnadsutformning och persontäthet viktigt för att avgöra energiprestanda på byggnaden. Studien visar att ju lägre formfaktor samt högre persontätheten i en och samma byggnad påverkar byggnadens energianvändning med en total minskning på 5.3[kWh/ m2 ,år]. / The purpose of the thesis project was to investigate how a building design affects it specific energy use. This was done by simulating different models of one preschool in IDA ICE. The basis for the study was the preschool Teleskopet which was located in the district Tavleliden in Umeå which was illustrated by models in IDA ICE and then make energy balance calculations. Four models with different form factors were built in IDA ICE. A single-storey house, a two-storey house, a three-storey house and a four-storey house were simulated to then determine the form factor in relation to the specific energy use varied. The models simulated in IDA ICE needed to have identical user data so that the form factor would change. The National Board of Housing, Building and Planning’s regulations on changing the board of directors were used, regulations and general guidelines (2016: 12) on the determination of the building energy use during normal use and a normal year (BEN 2), the National Board of Housing, Building and Planning’s regulations on changes in the National Board of Housing, Building and Planning’s building regulations (2011: 6) regulations and general guidelines; bfs 2020: 4 (BBR 29) and Umeå technical instructions from Umeå Municipality property were taken into consideration. In general, it turned out that single-storey houses had a higher form factor compared to those other models.The study showed that from a form factor of 2.4 to a form factor of 0.9 it reduced the specific energy consumption by 4.9[ kWh/m2,year ]. The same study also showed that if one increased the person density from [ 0.33pers/m2,Atemp ] to [ 0.5pers/m2,Atemp ] resulted in a decrease of 5.3[ kWh/m2,year ] on the specific energy use. In conclusion,the choice of building design and person density is important to determine the energy performance of the building. The study showed that the lower the form factor and the higher the density of persons in one and the same building were had an effect to the building’s energy use by one total reduction of 5.3 [ kWh/m2,year ].
|
67 |
Simulering av energieffektiviserande åtgärder i samband med ROT : En studie av flerbostadshus från 50-talet med hjälp av IDS simuleringJie, Gong January 2011 (has links)
ROT är förkortning till ” Reparation, Ombyggnader och Tillbyggnader ” som ä avsedd för skatteavdrag för vidtagna energibesparande åtgärder inom byggnadsektorn. Syftet med det här examensarbetet är att undersöka olika slags besparingar med hänsyn till dagens befintliga flerbostadshus omständigheter. Byggnadens energianvändning skulle generellt kunna minskas genom att förbättra klimatskal som exempelvis byggnadstekniska åtgärder och utnyttja nya installationstekniska åtgärder bl.a. som FTX ventilation system eller värmepumpar. Med hjälp av IDA ICE energisimuleringsprogram ska två flerbostadshusmodeller byggas. Resultatet från energiberäkningen med IDA ska analyseras och jämföras med bostadshusets energistatus idag. Avsikten med jamförelsen är att anpassa byggmodell för att representera den befintliga byggnaden så gott som möjligt. Förbättringsåtgärder som tillförs i byggmodellen ochberäknas med IDA skulle kunna påvisa olika potentialen av energibesparing. i olika förslagen .Även en ekonomiskbedömning av förbättringsåtgärder med valda åtgärder ska genomföras med ur livscykelkostnadssynpunkt som tar hänsyn till alla kostnader under kalkylperioden. Genom dessa kan fastigheter ägare få överblicka energikostnader för att avgöra ett rimligt och lönsamt beslut om energieffektiviseringsåtgärder. Nyckelord : åtgärder,befintliga flerbostadshus, IDA simulering, livscykelkostnad analys / The building sector accounts for almost one third of total energy use in Sweden. A large amount of residential buildings which were built one half century ago are in urgent need of renovation in order to reduce energy consumption meanwhile improving the inhouse comfort. This paper demonstrates that the heating need of apartment building from 1950s could be lowered by carrying out suggested measures. These include increasing the insulation layers on the roof and external wall, upgrade of windows in the building and reinstallation of ventilation system with heat exchange function. How much heating energy could potentially be cut down by implementation of each measure were examined by constructing and operating the model in the simulation program IDA Indoor Climate and Energy, which takes not only the indoor factors into account but also the external parameters like solar radiation , geographic location and surroundings. Finally the analysis on life cycle cost of each method has been performed based on reasonable assumptions in order to compare these measures in the term of costeffectiveness and give a more complete and sensible picture of energy effective means in the long run. Keywords : apartment building, heating energy reduction buildings envelop, model simulation, life cycle cost analysis, cost effectiveness.
|
68 |
Långsiktig klimat- och miljöpåverkan utifrån användandet av certifiering Miljöbyggnad 3.1 : En fallstudie på Strömsbro skolaHeidari, Nafiseh January 2021 (has links)
En av de mest debatterade frågorna i dagsläget är användningen av jordens resurser och hur dessa ska tas tillvara då efterfrågan ständigt ökar vilket medför ökad mängd klimatförändringar och växthusgaser. Idag beräknas byggnadssektorn stå för drygt en femtedel av Sveriges territoriella växthusgasutsläpp. Svenska byggnader står också för ungefär 30 % av Sveriges energianvändning, som går till el och uppvärmning. För att möta miljöproblemen som byggsektorn står inför styr boverkets byggregler utformning av byggnaderna och dess energisystem. Husbyggnadssektorn har dessutom ett flertal olika certifieringssystem som hjälper till med att göra miljömedvetna val. För att samla in data till arbetet har en fallstudie, litteraturstudie, livscykelanalys, simuleringsprogrammet IDA Indoor Climate Energi samt matematiska beräkningar genomförts. I fallstudien ingår en skolbyggnad, Strömsbro skola – Hus 10. Byggnaden byggdes år 2018 enligt Miljöbyggnad 3.0 dåvarande standard. Syftet är att granska och återbedöma byggnaden enligt manualen Miljöbyggnad 3.1 för nyproduktion. Sammantaget visar studien att det är svårare att uppfylla kraven i boverkets byggregler med fjärrvärme som uppvärmningssystem än en bergvärmepump. En byggnad vars uppvärmning kommer från fjärrvärme kräver mycket isolerade väggar för att uppnå ett högre betyg. Byggnader som är välisolerade har högre koldioxidutsläpp vid produktion men om byggnaden värms upp genom fjärrvärme blir utsläppen mindre sätt över byggnadens livstid. Fjärrvärmesystem reducerar utsläppet av växthusgaser med cirka 30% jämfört med bergvärmepump.
|
69 |
Energiutredning av en villa i Älvkarleby samt lönsamhetsanalys av solcellerUmer, Diyar January 2021 (has links)
Energiutredning av gamla fastigheter är en betydelsefull åtgärd i dagens samhälle för att kunna identifiera och föreslå energieffektiviseringsåtgärder för att kunna minska dess totala energianvändning.Avsikten med denna utredning är att framställa olika förslag för att minimera energianvändningen för en villa i Älvkarleby samt analysera lönsamheten för en installation av en solcellsanläggning. Det undersökta objektet är en 1860-tals timmervilla med en boarea på cirka 400 m2 uppdelat på två våningar, villan renoverades ett antal gånger, då senast tilläggisolerades taket och installerades en luft-luftvärmepump för att minimera elkostnader.En modell skapades i IDA ICE-programmet i avsikt att kunna dela upp de olika energiförluster genom byggnadsskalet såsom tak, golv, väggar och fönster.En installation av en ny luft-luftvärmepump kan ge till resultat att energianvändningen minskas ytterligare med 20 %, detta eftersom den aktuella luft-luftvärmepumpen redan har minskat energianvändningen och därmed elkostnader. Denna typ av värmepump valdes då den har låga installationskostnader samt att det redan existerar en luft-luftvärmepump. Återbetalningstiden för den nya luft-luftvärmepumpen blir 3 år, detta kan dock variera beroende på drifttiderna genom åren.Solcellernas lutning och orientering är oftast optimerade för att maximera den totala årliga elproduktionen. Ändå kan detta inte alltid vara lönsamt utifrån det ekonomiska perspektivet.Ett flertal anläggningar testades med avseende på deras effekt och väderstreck då fastigheten har ett begränsat tak area i söderläge, detta gjordes med hjälp av WINSUN PV-programmet. En solcellsanläggning riktad mot syd och öster på 4,1 kW ansågs vara mest lönsamt bland de undersökta anläggningar då denna anläggning sparar nästan 89% av den producerade elen, då den används direkt i fastigheten.Kostnaden per kW blir lägre ju större anläggningen blir, vilket gör att anläggningen kommer att ha en ungefärlig återbetalningstid på 15 år. Men detta kan troligen påverkas av framtida elpriser, ekonomiska understöd samt fastighetens elanvändning under sommarperioden.
|
70 |
Klimatanpassning av block B2-B7 på Akademiska sjukhuset med avseende på ovanligt höga temperaturer i framtidenPaulsson, Kajsa January 2021 (has links)
The aim of this thesis has been to examine how the indoor climate in block B2-B7 at Uppsala University Hospital is affected by unusually high outdoor temperatures and to propose measures which can be taken in order to maintain the desired indoor climate. This was done through simulations in the software IDA ICE. The results show that the indoor temperatures exceed the permitted maximum limit in most of the floors in the buildings, and that measures must be taken in order to guarantee an acceptable indoor climate. Two of the analyzed measures, reduction of internal heat loads and mitigation of the urban heat island effect, could not be quantified and it was not possible to determine the extent of their impact on the indoor climate. However, installation of external sunscreens on the windows to the south and west turned out to reduce the cooling demand of the buildings with approximately 130 kW and should therefore be considered a relevant measure. Sunscreens alone were not sufficient to keep the indoor temperature below the maximum limit and there is therefore a need to expand the cooling capacity in the buildings by installing more air coolers. The cooling power deficit was estimated to be 360–440 kW through simulations, given that the outdoor temperature is in the interval 36–45°C. Among the proposed measures, sunscreens should have the highest priority due to the energy saving aspect. In addition to this, the installation of air coolers has been divided into phases based on indoor temperature in the respective buildings and floors. Within the phases, a further prioritization with respect to the activity type of each floor is considered necessary. The final product of the study is an action plan which can be used in the work of climate adapting the buildings.
|
Page generated in 0.0294 seconds