• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 117
  • 82
  • 6
  • 5
  • 4
  • 4
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 231
  • 140
  • 111
  • 86
  • 52
  • 39
  • 39
  • 35
  • 34
  • 34
  • 31
  • 30
  • 28
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Energikartläggning av ”Kontoret” vid Dåvamyrans kraftvärmeverk : En energikartläggning utförd med IDA ICE för en modern kontorsbyggnad hos Umeå Energi

Andersson, Jakob January 2016 (has links)
The law on energy audits for large companies was adopted by the Swedish Parliament in 2014 and implies that companies that answer to the law are to present a representative picture of their energy consumption. In addition, suggestions for cost-effective measures are to be made, that will lead to reduced energy consumption and more efficient use of energy. This energy audit was made in accordance with directives and the Swedish Energy Agency’s recommendations. It was done for Umeå Energy’s office building at Dåvamyrans CHP, which is their largest CHP for district heating. The building was completed in 2007, and is connected to the powerplant Dåva 1 by a subsurface tunnel. Dåva 2 was completed in 2010 to meet the increased need for heating in Umeå, and to reduce the share of oil in Umeå Energy's fuel mix. It is a highly energy efficient and environmentally sound facility for the production of district heating.   As an energy simulation program IDA ICE performs very well when it comes to estimating a building's actual energy consumption, this program will be used for the energy audit of the office. The energy audit separates itself to estimate the energy consumption in the building for heating, cooling, building electricity and business electricity and exclude the external consumptions for lighting and transports.   Measurements were taken for a week for the buildings electricity consumption. The values were then used together with an inventory of the effects of lighting, electrical components and assumptions for electricity consumption for the office part, to appreciate the building's total needs of business electricity. Inventories of ventilation and temperature measurements were made to get the heating demand for the model. Personal Attendance was also estimated, to be able to simulate the cooling need for which measurements are not available. The model was corrected thoroughly to match the estimated electric consumption and the heat consumption that had been measured, and corrected on the basis of boundaries for the model.   The results showed that the building has a total annual energy requirement of 157,5 [kWh/m2], 97 [kWh/m2] for district heating, 55,2 [kWh/m2] for electricity consumption and 5,1 [kWh/m2] for district cooling . The corrected simulation according to measurements and estimates was used to make an energy balance for district heating, and to simulate different improvement actions that was later analyzed for individual and simultaneous influence on each other.   A conclusion was drawn that the measure which favors both district heating, district cooling and electricity consumption, is a combination of all limited measures including the replacement of LED lamps for certain areas, turning of the lights and shutting down computers after hours, as well as the reduction of the air handling units operating times and reducing the temperature with one degree for the entire building. These combined measures balance and affect each other positively, and can provide potential savings of between 27 000 and 37 000 [SEK] per year depending on varying energyprices district heating and electricity.    Other practical measures that should be done is conducting measurements for the hot water demand, cooling need and electricity consumption for the building, since they aren’t being conducted currently. An adjustment of the ventilation flows should also be made, this is because some diverging flows were detected during measurements. It should be examined how the activation of night cooling functions during the summer. If it would be activated during summer it would provide a reduced cooling requirement.    Keywords: Energy Audit, Energy Efficiency, District Heating, Electricity Consumption, IDA ICE, Umeå Energi / Lagen om energikartläggning för stora företag antogs av Sveriges Riksdag år 2014 och innebär att företagen som är inräknade ska redovisa en representativ bild av sin energiförbrukning. Dessutom ska det lämnas in föreslag för att göra kostnadseffektiva åtgärder, som ska leda till en minskad energiförbrukning och effektivare användning av energi. Denna energikartläggning har gjorts enligt lagens riktlinjer och Energimyndighetens rekommendationer för energikartläggningar. Kartläggningen gjordes för kontorsbyggnaden vid Dåvamyrans kraftvärmevärk, som är Umeå Energis stora produktionsanläggning för fjärrvärme. År 2007 färdigställdes kontoret och ligger i anslutning till Dåva 1 via en tunell under jorden. Dåva 2 färdigställdes 2010 för att möta det ökade behovet av fjärrvärme i Umeå och för att minska andelen olja i Umeå Energis bränslemix. Den är en väldigt energieffektiv och miljöanpassad anläggning för produktion av fjärrvärme.   Eftersom energisimuleringsprogrammet IDA ICE presterar mycket bra när det kommer till att uppskatta en byggnads verkliga energiförbrukning, kommer detta program att användas för energikartläggningen av byggnaden. Energikartläggningen avgränsar sig till att endast ta med energiförbrukningen inom byggnaden för uppvärmning, fjärrkyla, fastighetsel och verksamhetsel. Från kartläggningen exkluderas den yttre förbrukningen i form av belysning, motorvärmarstolpar och transporter som tillkommer i verksamheten.   Mätningar gjordes under en vecka för elförbrukningen. Dessa användes sedan tillsammans med inventerade effekter för belysning, elektriska komponenter och antaganden för elförbrukningen för kontorsdelen till att uppskatta byggnadens totala behov av verksamhetsel. Inventeringar av ventilation och mätningar för temperaturer gjordes för att få uppvärmningsbehovet för modellen. Personnärvaro uppskattades också för att kunna simulera ett fjärrkylabehov där mätningar inte finns att tillgå. Modellen korrigerades grundligt för att matcha den uppskattade elföbrukningen och fjärrvärmeförbrukningen som hade mätts, normalårskorrigerats och korrigerats utifrån avgränsningar.    Resultatet visade att byggnaden har ett totalt årligt energibehov på 157,5 [kWh/m2], varav 97 [kWh/m2] för fjärrvärme, 55,2 [kWh/m2] för elförbrukningen och 5,1 [kWh/m2] för fjärrkylan. Grundsimuleringen användes för att göra en energibalans för fjärrvärmen och simulera för olika förbättringsåtgärder som senare analyserades för enskild och sammanlagd påverkan på varandra.    Som slutsats drogs att den åtgärd som gynnar både fjärrvärme, elförbrukning och fjärrkylaförbrukning, är en kombination för alla begränsade åtgärder som innefattar byte av led lampor, släckning av belysning och avstängning av datorer efter arbetstid, reducering av ventilationssystemets drifttider och reducering av temperaturen i byggnaden med en grad. Dessa sammanlagda åtgärder balanserar och påverkar varandra positivt och kan ge en potentiell besparing på mellan 27 000 och 37 000 [kr] per år beroende på varierande energipris för el och fjärrvärme.    Andra praktiska åtgärder som framgår av metodavsnittet är att mätningar för tappvarmvatten, fjärrkyla och byggnadens elförbrukning borde införas eftersom sådana mätningar inte görs i nuläget. En injustering av ventilationsflöden borde också göras, detta eftersom avvikande flöden upptäcktes under mätningar. Sedan borde det undersökas hur aktiveringen av nattkyla fungerar under sommartid, att det ses till så att den är på, eftersom det skulle ge ett reducerat kylbehov för den varma perioden om den inte vore aktiverad.   Nyckelord: Energikartläggning, Energieffektivisering Fjärrvärme, Elförbrukning, IDA ICE, Umeå Energi, Umeå / Nej
82

SIMULERING AV SPECIFIK ENERGIANVÄNDNING FÖR ETT FIKTIVT ATTEFALLSHUS : En undersökning om ett generellt Attefallshus kan klara det nu gällande BBR-kravet för småhus

Netzell, Pontus January 2016 (has links)
Energy efficiency in the building sector is crucial for many countries in succeeding with the completion of goals regarding energy efficiency. This study has investigated if there are any possible and reasonable solutions for Attefallshus in Sweden to meet the demands of the National Board of Housing regarding energy performance in houses. By building a model and calculating the annual energy usage for a specific Attefallshus, through simulations with the software IDA ICE and general input, an energy audit has been obtained. By comparing the specific energy usage for the studied case with the requirement the conclusion that it is possible for this small building to achieve a low enough energy usage to meet the demand. Solar cells are the key to accomplish the target of a low specific energy usage and by combining this with an effective system for heating it possible to get under the limit. The usage of domestic hot water is a very large part of the building specific energy usage and alone almost reaches the set bounds which is why it is of great importance to carefully design systems and to regain heat with effective ventilation. A large part of the energy usage in Attefallshus is related to the user why awareness and careful usage of energy is a significant factor in reaching a low specific energy usage.
83

Energihushållning och varsamhet för äldre byggnader : Chefsbostaden i Strömsholm, ett timmerhus från 1900-talets början

Ölander, Ylva January 2014 (has links)
This report is the result of a degree project in building engineering, at an advanced level. The project evaluated a building from a technical and historical point of view, and focused on its energy consumption, particularly the energy used for heating. The building in question was a small apartment building in Strömsholm, Sweden. It was made in 1902, from vertical logs, a not so common form of the traditional log house. The goal of the project was to evaluate if the energy consumption could be reduced in accordance with building preservation regulations, that is without damaging any of the building’s cultural or historical values. The building was surveyed with the help of archive and literature studies, interviews and inspections. Based on these findings, supplementary insulation on the inner side of the climate screen was decided on. The program IDA Indoor Climate and Energy was used to make computer simulations of the energy consumption of the building for five different alternatives of supplementary insulation. Part of the project was also to investigate whether IDA Indoor Climate and Energy was suitable for energy simulations of old buildings. The moisture balance of the outer walls was calculated manually to see if the supplemental insulation constituted a risk when it came to the moisture sensitivity of the construction. The result of the computer simulations, combined with building physics, shows that the energy consumption for heating could be reduced, especially if the roof was to be insulated. However, these results cannot and should not be seen as anything but indications, because of the uncertainty of the input data. The data on ventilation and air flows was considered to be one of the main sources of error. Furthermore, there were signs that the design of the computer models was far from optimal. The result of the moisture calculations shows that the moisture sensitivity is indeed increased. IDA Indoor Climate and Energy was judged as more suitable for simulations of new buildings than of old ones, due to the complexity of the latter, but the program can still be used as an aid for energy evaluations of old buildings if it is used in the right way. / Denna rapport är resultatet av ett examensarbete i byggnadsteknik på avancerad nivå. Arbetet gick ut på att undersöka en byggnad ur ett tekniskt och kulturhistoriskt perspektiv, med inriktning på hushållning av energi. Föremålet för undersökningen var ett flerbostadshus i restimmer, uppfört 1902 i Strömsholm, Västmanland. Målet var att undersöka om byggnadstekniska åtgärder behövdes för att minska energiåtgången, främst den för aktiv uppvärmning, i byggnaden. Dessa åtgärder skulle utformas så att byggnadens bevarandevärda särdrag inte går förlorade, i enlighet med Plan- och bygglagens bestämmelser om ändring av byggnader. Med hjälp av arkivsökningar, litteraturstudier, intervjuer och undersökningar kartlades byggnaden. Utifrån dess förutsättningar bestämdes förslag för energibesparande åtgärder, fem olika alternativ för invändig tilläggsisolering. För att beräkna byggnadens energiåtgång och hur mycket de olika alternativen skulle kunna påverka denna gjordes simuleringar i programmet IDA Indoor Climate and Energy. En av frågeställningarna i arbetet var huruvida detta program var lämpligt för energisimuleringar av äldre byggnader eller inte. Beräkningar av den relativa luftfuktigheten i ytterväggen gjordes för hand för att bedöma fuktskaderisken i konstruktionen efter tilläggsisolering. Indata till fuktberäkningarna och datorsimuleringarna hämtades från litteraturen eller utgjordes av uppskattningar. Resultat av datorsimuleringarna, tillsammans med byggnadsfysiska resonemang, visar att det går att minska energiåtgången för uppvärmning, driftel och tappvarmvatten, i synnerhet vid tilläggsisolering av taket. Dock kan inte dessa resultat ses som något annat än indikationer eftersom osäkerheterna i indata för modellerna var för stora. Bristande indata för ventilationen bedömdes vara en av de största felkällorna. Dessutom föreligger vissa reservationer gällande modellernas utformning. Resultatet av fuktberäkningarna visar att väggarna blir känsliga för fuktskador vid invändig tilläggsisolering. IDA Indoor Climate and Energy bedöms vara lämpligare för simuleringar av nyproducerade byggnader än av äldre byggnader på grund av komplexiteten hos de senare, men det kan ändå fungera som ett hjälpmedelvid energiutvärderingar av sådana om det används rätt.
84

Utvärdering av energiprojektering för Hedlunda passivhusförskola : Assessment of the projected energy demand for a passive house preschool at Hedlunda

Risberg, Ylva January 2017 (has links)
På Hedlunda i Umeå finns Hedlunda förskola; en byggnad som innehåller förskoleverksamhet, ett storkök och en matsal. Byggnaden uppfördes 2014 och började nyttjas samma år. Byggnaden är projekterad av Sweco för att klara krav gällande allt från specialpedagogik till energi och miljö. Den är även certifierad enligt en internationell passivhusstandard. Syftet med examensarbetet är att granska om förskolan håller de energikrav den projekterats för, samt att jämföra byggnadens projekterade energianvändning med den i praktiken uppmätta. Det sistnämnda gjordes även för att utvärdera precisionen hos den projekterade energianvändningen. Energibehovet ställdes även i proportion till de gränsvärden för energikrav som används av andra energicertifieringar. Byggnaden simulerades i programmet IDA ICE, och de mätvärden som samlades in bearbetades i Microsoft Excel. Programmet PHPP användes även för att granska om förskolan uppfyllde de internationella passivhuskraven. Byggnaden klarar varken kravet för årlig energianvändning eller kravet för specifikt primärenergibehov. Båda dessa är krav inom den internationella passivhusstandarden. Det föregående överskrids med 14 %, och det senare med 4 %. Byggnaden klarar energikravet för den svenska passivhuscertifieringen med god marginal. Värdet på byggnadens specifika energianvändning skilde sig knappt alls mellan projekteringen och det uppmätta värdet. Tittar man dock på enskilda faktorer så skiljer sig de projekterade värdena av el och uppvärmning sig mot de uppmätta med större differenser. Störst differens återfinns i faktorn verksamhetsel som överskattades med 60 % i projekteringen. Byggnadens specifika energianvändning uppgick till ca 43 kWh /m2 år  vilket är lägre kraven de vanligaste energistandardena ställer, vilket innebär att byggnaden är osedvanligt energieffektiv. Om alla lokaler som fick bygglov i Sverige 2015 hade byggts med samma energiprestanda som denna byggnad så hade det gått åt 392 GWh /år , medan om de istället byggts enligt BBRs standard så hade energiåtgången blivit 1098 GWh /år  (exklusive verksamhetsel). Även om olika lokaler har olika behov och krav så ger det en fingervisning av besparingspotentialen. Syftet med byggnaden var att det skulle bli en förebild för framtida energisnåla projekt, vilket det också blev när Vegaskolan i Vännäs byggdes efter samma koncept. På det hela taget är Hedlunda förskola en byggnad med hög energiprestanda. / At Hedlunda in Umeå, there’s a building complex containing a combined preschool, canteen and catering kitchen. It was built in 2014 and the preschool started up the same year. Sweco projected the building to satisfy the requisites required for the international passive house certification. The building was also supposed to meet specific requirements for specialized pedagogy, and requirements for non-toxic building materials in preschools, amongst others. In this master thesis the building’s energy usage was studied to see if the building met the requested requirements, and how close the estimated energy demand was to the actual demand. The purchased energy was also compared to energy requirements used by other certification systems used in Sweden today. The building meets the international passive house requirement for the annual heating demand, but breaches the requirement for primary energy value by 4 %. The Swedish passive house requirement is met with a significant margin. The purchased energy per square meter was 43 kWh /m2 year , which differed only marginally from the projected value of 41 kWh /m2 year . It may seem as if it was a very good estimation of the purchased energy, but when the factors are studied individually there are differences among them that go up to 60 %. The purchased energy per square meter was lower than all of the other requirements in other energy certification systems which proves that this is a highly efficient building. The building was created with the main purpose of serving as a model for energy efficient buildings, and it has served its purpose since Vegaskolan in Vännäs was built within the same concept. All in all, Hedlunda preschool is a building with a very good energy performance. If all public buildings who gained building permit in 2015 in Sweden had been built with the same energy efficiency as Hedlunda preschool, then the total energy demand would be 392 GWh /year , whereas if they were built as the BBR-standard the corresponding energy demand would be 1098 GWh /year . This is just a rough estimation to give a hint of the amount of energy that can be saved.
85

Passivhus ur en brukares perspektiv / Passive houses from a user's perspective

Samuelsson, Marcus, Lüddeckens, Thomas January 2009 (has links)
Ett passivhus är ett hus som i stort sett enbart värms upp av människorna och elapparaterna som finns i huset. Särskilda krav för att få kalla huset för passivhus måste uppfyllas. Vi har gjort en enkätundersökning på tre olika passivhusprojekt för att utreda vad de boende tycker om inomhusklimatet. De utvalda projekten finns i Värnamo, Frillesås och Glumslöv. Enkätsvaren visar att de boende i Frillesås är mycket nöjda, medan mer än 50 % av dem som bor i Glumslöv tycker att det är för varmt på sommaren och för kallt på vintern. För att utreda om de olika konstruktionerna har någon inverkan på inomhusklimatet har beräkningar och simuleringar i datorprogrammen VIP+ och IDA gjorts. Resultaten från de båda programmen visar att vilken av de två konstruktionerna som valts inte bör ha någon påverkan på inomhusklimatet. / A passive house is a house that is mostly heated with energy from humans and from electric devices in the house. Special requirements need to be followed if you want to call the house a passive house. We did a survey on three different passive house projects to investigate the tenants opinion about the indoor climate. The chosen projects are located in Värnamo, Frillesås and Glumslöv. The result of the survey shows that the tenants in Frillesås are very satisfied, while more than 50 % of the tenants in Glumslöv think it’s too hot in the summer and too cold in the winter. To investigate if the construction has any effect on the indoor climate, we did calculations and simulations in the computer programs VIP+ and IDA. The result from both of the programs shows that the chosen construction should not effect the indoor climate.
86

Fuktförebyggande åtgärder för ett bättre klimat i den småländska stenkyrkans krypgrund / Moisture preventative actions, in order to ensure a better environment in the crawl space of thestonechurches of Småland

Ekelöf, Henrik, Hasselby, Fabian January 2010 (has links)
Fukt i kyrkans krypgrund är ett ”växande” problem som på senare tid uppmärksammats alltmer. I denna studie har flera möjliga lösningar undersökt, vidare har en allmän angreppsmodell formulerats för att underlätta framtida utredningar. Studien visar bland annat att styrning efter mögelrisken är önskvärt för att få ett energioptimerat och garanterat mögelfritt klimat. Åtgärdsförslag såsom sorptionsavfuktare samt värmning genom elradiator direkt i krypgrunden är möjliga lösningar som med ett litet energitillskott förbättrar klimatet i krypgrunden avsevärt.
87

Passivhus ur en brukares perspektiv / Passive houses from a user's perspective

Samuelsson, Marcus, Lüddeckens, Thomas January 2009 (has links)
<p> </p><p>Ett passivhus är ett hus som i stort sett enbart värms upp av människorna och elapparaterna som finns i huset. Särskilda krav för att få kalla huset för passivhus måste uppfyllas.</p><p>Vi har gjort en enkätundersökning på tre olika passivhusprojekt för att utreda vad de boende tycker om inomhusklimatet. De utvalda projekten finns i Värnamo, Frillesås och Glumslöv. Enkätsvaren visar att de boende i Frillesås är mycket nöjda, medan mer än 50 % av dem som bor i Glumslöv tycker att det är för varmt på sommaren och för kallt på vintern. <strong></strong>För att utreda om de olika konstruktionerna har någon inverkan på inomhusklimatet har beräkningar och simuleringar i datorprogrammen VIP+ och IDA gjorts. Resultaten från de båda programmen visar att vilken av de två konstruktionerna som valts inte bör ha någon påverkan på inomhusklimatet.</p><p> </p> / <p><p>A passive house is a house that is mostly heated with energy from humans and from electric devices in the house. Special requirements need to be followed if you want to call the house a passive house.<strong></strong></p><p>We did a survey on three different passive house projects to investigate the tenants opinion about the indoor climate. The chosen projects are located in Värnamo, Frillesås and Glumslöv. The result of the survey shows that the tenants in Frillesås are very satisfied, while more than 50 % of the tenants in Glumslöv think it’s too hot in the summer and too cold in the winter.</p>To investigate if the construction has any effect on the indoor climate, we did calculations and simulations in the computer programs VIP+ and IDA. The result from both of the programs shows that the chosen construction should not effect the indoor climate.</p>
88

Energieffektivisering av uppvärmningssystem i småbostadshus / Improving energy efficiency of a heating system in a single-family detached home

Dahlberg, Emil January 2015 (has links)
Uppvärmningen av ett småbostadshus står vanligen för kring hälften av dess energianvändning. Enligt energimyndigheten drar det svenska standardhuset 22,7 MWh per år varav 12,2 MWh går till uppvärmning. Att ge värmesystemet så bra förutsättningar som möjligt bör alltså vara av intresse för varje husägare, kanske främst ur ett ekonomiskt perspektiv men även ur ett ekologiskt perspektiv. I detta arbete har olika energieffektiviseringsåtgärder studerats som kan implementeras i en tvåplansvillas värmesystem bestående av en värmepump, golvvärme på nedervåningen och olika värmedistributionssystem på övervåningen. Åtgärderna har innefattat både praktiska såsom val av isolering i golvvärmesammanhang och mer teoretiska såsom reglerstrategier. Relevant teori för de ingående systemen har presenterats och utgjort grunden för implementeringar av systemen i simuleringsprogrammet IDA Indoor Climate and Energy. Programmet har använts för att simulera en modellbyggnad utrustad med de olika systemlösningarna varvid resultaten sedan jämförts mot varandra. Det mest energieffektiva systemet på övervåningen har visat sig vara lågtempererade radiatorer tack vare kombinationen med golvvärme på nedervåningen vilket tillåter värmepumpen att arbeta med en lägre värmekurva. Även då golvvärme på övervåningen användes erhölls en låg energiförbrukningen, dock på bekostnad av komforten. Elradiatorer, vilka inte kan utnyttja energin som värmepumpen hämtar ur värmekällan, gav den högsta energiförbrukningen. / Heating of a single family residence usually constitutes about half of the total energy consumption. According to Energimyndigheten, the average Swedish house consumes 22,7 MWh whereof 12,2 MWh goes to heating. To bring about as good conditions for the heating system as possible should be of interest for every house owner, maybe mostly out of an economic point of view but also out of an ecologic point of view. This work have studied different efforts aiming towards a more energy efficient system that can be implemented in the heating system of a two story single-family house equipped with a heat pump, floor heating on the first floor and different heat distribution systems on the second floor. The different efforts include both practical such as choice of insulation in relation to floor heating and more theoretical such as control strategies. Relevant theory for the different subsystems has been presented and used for implementation in the simulation software IDA Indoor Climate and Energy. The program was used to simulate a building model equipped with the different heating systems in which the results are compared to each other. The most energy efficient system on the second floor proved to be low temperature radiators due to the combination with the floor heating system on the first floor which allows the heat pump to operate with a lower heating curve. Although floor heating on the second floor also yielded a low energy consumption, it was at the expense of comfort. Electric radiators, which cannot take advantage of the energy the heat pump collects from the heat source, yielded the highest energy consumption.
89

Förbättring av Egenvärmehus : En fallstudie av ett flerbostadshus, Kv. Fyrtornet

Yamabo, Deo Gratias January 2013 (has links)
Energy efficiency has become a very topical issue that has been discussed throughout the European Union for preventing negative environmental impacts that have been associated with the consumption of energy. In the residential sector have mainly municipalities set strict requirements for the reduction of energy consumption while the renewable energy has been asked. Different concepts of low-energy buildings have been developed to reduce the cost of operation and maintenance in existing buildings such as in new ones. This thesis has aimed to minimize the energy cost of a large building which has had low energy consumption features originally. Energy reviews has been initiated in order to be able for showing how the house electricity could be carried out even more efficiently. The work was initiated through a literature study to clearly increase the reliability on the energy subject. Different concepts of low-energy buildings have been treated in connection with its specifications, afterward those have been compared with the obtained results. An analysis of the building’s energy use has been carried out as well as economic evaluation has been considered in order to the viability of the energy efficiency measures that have been proposed. Energy demand for the studied building has been valued at 48, 7 kWh/m2 annually in its original form. The obtained value has been lower than the required energy which has been promoted in Building Regulations, BBR 18. After the improvement of building has been performed, by using a package of measures, the building has been upgraded to a passive house level and the energy demand has become 21, 5 kWh/m2 annually. A reasonably large amount of energy has been reduced in connection with the improvement package as well as the whole profitability has proven to be economic sustainable. By integrating solar energy systems in the building, its result has shown a biggest benefit for saving energy. / Energieffektiviseringen har blivit en mycket aktuell fråga som har diskuterats inom Europeiska Unionen för att förebygga negativa de miljöpåverkan som förknippats med energiförbrukning. Inom bostadssektorn har främst kommuner ställt strikta krav som har fått energianvändningen att reduceras samtidigt som har brukande av förnybara energin gynnats. Olika koncept av lågenergibyggnader har därför utvecklats för att begränsa kostnader för drift och underhåll. Examensarbetets syfte har varit att kostnadseffektivt minimera energibehovet i ett flerbostadshus som från början har lågenergi inslag. En energikartläggning har inletts för att sedan kunna visa hur hus el skulle kunna utföras ännu effektivare. Arbetet har inletts med en litteraturstudie för att tydligt öka kunskapen i ämnet energihushållning. Olika begrepp av lågenergibyggnader har behandlats i samband med dess kravspecifikationer som efteråt har jämförts med det erhållna resultatet. Det har också genomförts en analys över byggnadens energianvändning. Ekonomiska bedömningen har beaktats i analysen för att överväga lönsamheten av de energieffektiviserande åtgärderna som har föreslagits. Den evaluerade byggnadskroppen har inledningsvis åtgärdats individuellt för att se vilka av de förbättringsmöjligheterna som har medfört störst energibesparing. Därefter har det gjorts flera energioptimeringsåtgärder samtidigt. Dock har utredningen visat sig vara omöjlig för att spara en stor energimängd med enstaka åtgärder. Energiprestanda för den studerade byggnaden har beräknats till 48,7 kWh/m2 årligen i sitt originalutförande, vilket har varit lägre än den energigränsen som förespråkats i Boverkets byggregler 18 då huset konstruerades. Efter vidtagande av åtgärdspaketet har energibehov kommits åt passivhusnivån med en prestanda på 21,5 kWh/m2 per år. En någorlunda stor mängd av energin har reducerats i samband med åtgärdspaketet samt att den totala lönsamheten har visat sig vara ekonomisk hållbar. Solenergisystem har varit den största fördelen till att energibesparingen har kunnat säkerställas.
90

Problem och förbättringsåtgärder för termisk komfort och energi på en glasbyggnad i Gävle – en fallstudie

Käck Nauclér, Johan, Sandberg, Peter January 2018 (has links)
Det byggdes många byggnader med fasader av glas under 90-talet. Arkitekterna ville med detta framhäva en design som var luftig, ljus, genomskinlig och som hade god tillgång till naturligt dagsljus. Dock finns problem med dessa byggnader eftersom de ofta har hög energianvändning och dålig termisk komfort. I denna fallstudie undersöktes glasbyggnaden Bråbänken i Gävle, den hade vid till- fället problem med den termiska komforten då byggnaden upplevdes för varm på sommaren och för kall på vintern. Vidare var energianvändningen för byggnaden hög då den var dåligt isolerad och hade hög solinstrålning. Studien gick ut på att komma till rätta med dessa problem genom att bygga en termisk numerisk modell av byggnaden i simuleringsprogrammet IDA-ICE och sedan studera olika förbätt- ringsåtgärder genom att ändra indatan för byggnadens olika komponenter. Resultatet av simuleringarna visade att en reduktion av solinstrålningen genom sol- film och screenväv förbättrade den termiska komforten på sommaren men margi- nellt försämrade den på vintern. Årsenergianvändningen reducerades för åtgärderna genom att byggnaden i högre grad bibehöll sin värme på vintern och minimerade kylbehovet på sommaren. Slutsatsen blev att en kombinerad åtgärd med ickemetallisk solfilm på väggfönster och screenväv på taket är den bästa lösningen för att komma tillrätta med problemen vad gäller termisk komfort och energianvändning för glasbyggnaden Bråbänken. / There was a lot of construction of buildings with glazed facades during the 90 ́s. The architects wanted to show a design that was airy, bright, transparent and that had a good availability of natural daylight. However there is a problem with these build- ings because they have a high energy consumption and bad thermal comfort. In this case study a glass building in Gävle called Bråbänken was studied, which at the moment has problems with thermal comfort according to the occupants who complained about it being to hot in the summer and to cold in the winter. Further- more the energy consumption for the building was high because it was poorly insu- lated and had high solar radiation. The study aimed at addressing these problems by creating a thermal model of the building in the energy simulation program IDA-ICE and then study different improvements by changing the input values for various components of the model. The results of the simulations showed that by reducing the solar radiation through solar film and screen fabrics improved the thermal comfort in the summer but mar- ginally deteriorated it in the winter. The annual energy consumption was reduced by minimizing the use of energy for heating in the winter and of cooling in the sum- mer. The conclusion was that a combination of non-metallic solar film on walls and screen fabrics on the roof is the best solution to improve the thermal comfort and energy consumption for the glass building Bråbänken.

Page generated in 0.317 seconds