• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 199
  • 60
  • 45
  • 32
  • 29
  • 17
  • 7
  • 7
  • 7
  • 5
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 455
  • 99
  • 66
  • 52
  • 51
  • 50
  • 49
  • 47
  • 46
  • 41
  • 36
  • 35
  • 35
  • 33
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Resíduos de pesticidas organoclorados e bifenilos policlorados em sedimentos e algas de Santos e Cananéia, SP, Brasil / Waste of organochlorine pesticides and polychlorinated biphenyls in sediments and algae of Santos and Cananéia- SP Brazil

Matos, Maria Auxiliadora Costa 03 December 2002 (has links)
Bifenilos policlorados (PCBs) e pesticidas organoclorados são poluentes resistentes à degradação e têm sido identificados em vários compartimentos do ambiente marinho. O objetivo deste trabalho foi otimizar e validar a metodologia, e avaliar a contaminação por pesticidas organoclorados e PCBs em algas e sedimentos costeiros no Estuário e Baía de Santos-São Vicente e no Complexo Estuarino-Lagunar de Iguape e Cananéia (SP). Foram coletadas nessas regiões um total de 37 amostras de sedimento superficial, 3 testemunhos com 27 sub-amostras e 10 amostras de alga, no período de 1998-2001. O método, que incluiu a extração e purificação com solventes orgânicos e análise por GC-ECD, mostrou-se satisfatório dentro dos padrões internacionais. Na região de Cananéia-Iguape predominaram os DDTs (sedimentos: 0,78 a 14,52 ng.g-1 peso seco) e as maiores concentrações ocorreram nas proximidades da Cidade de Cananéia e Baía de Trapandé. Na região de Santos predominaram os PCBs (sedimentos: 4,08 a 133,42 ng.g-1 peso seco, testemunhos de sedimentos: 3, 70 a 44,65 ng.g-1 peso seco e algas: 15,83 a 43,21 ng.g-1 peso seco) e os maiores valores foram encontrados no emissário submarino, no Estuário de Santos, em locais próximos as indústrias, e no Estuário de São Vicente. De maneira geral, as concentrações tanto de PCBs quanto de pesticidas organoclorados em Santos e Cananéia-Iguape foram baixas. Santos apresentou maior incidência de PCBs, provavelmente devido à industrialização, enquanto que em Cananéia-Iguape predominaram os pesticidas organoclorados, que podem ser atribuídos às antigas campanhas de saúde pública ou aplicações nas lavouras. / Polychlorinated biphenyls and chlorinated pesticides are degradation resistant pollutants. They have been detected in several compartments of marine environment. The objective of this study was the optimization of the methodology and the evaluation of the contamination of chlorinated pesticides and PCBs em algae and coastal sediments in the Estuary and Bay of Santos-São Vicente and in the Lagunar Complex of Iguape and Cananéia (SP). An amount of 37 samples of superficial sediment, 3 cores with 27 subsamples and 10 samples of algae was collected in the period of 1998-2001. The methodology was considered satisfactory within international standards, that includes extraction and clean up with organic solvents and analysis with GC-ECD. In the Cananéia-Iguape region, DDTs were predominant and the highest levels were found around the city of Cananéia and in Trapandé Bay. In the Santos area, the PCBs were predominant and the highest values were found around the Santos Bay outfall and in the Estuary of Santos-São Vicente. In general, either the concentrations of PCBs or chlorinated pesticides in Santos and Cananéia-Iguape were low. Santos presented higher incidence of PCBs, probably due to industrialization, while in Cananéia-Iguape the chlorinated pesticides predominated, and that can be attributed to past public health campaigns or to agricultural uses.
252

Projeto e análise de aplicações de circuladores ativos para a operação em frequências de ultrassom Doppler de ondas contínuas / Design and application analysis of active circulators for operation in frequencies of continuous-wave Doppler ultrasound

Santini, Tales Roberto de Souza 11 July 2014 (has links)
Os circuladores tradicionais são amplamente utilizados em telecomunicações e defesa militar para o simultâneo envio e recepção de sinais por um único meio. Esses circuitos passivos, fabricados a partir de materiais ferromagnéticos, possuem a desvantagem do aumento de dimensões, peso e custos de fabricação com a diminuição da frequência de operação definida no projeto destes dispositivos, inviabilizando sua aplicação em frequências abaixo de 500 MHz. O circulador ativo surgiu como uma alternativa aos tradicionais, tendo aplicações em frequências desde o nível DC até a ordem de dezenas de gigahertz. As suas maiores aplicações ocorrem quando são necessários dispositivos compactos, de baixo custo e de baixa potência. Os primeiros circuitos propostos possuíam uma grande limitação em termos de frequência de operação e de potência entregue à carga. Entretanto, com os avanços tecnológicos na eletrônica, tais problemas podem ser amenizados atualmente. Neste trabalho é apresentado o desenvolvimento de um circuito circulador ativo para a utilização em instrumentação eletrônica, em particular para a operação em frequências na ordem das utilizadas em equipamentos de ultrassom Doppler de ondas contínuas, na faixa de 2 MHz a 10 MHz. As possíveis vantagens da implementação de circuladores em sistemas de ultrassom estão relacionadas ao incremento da relação sinal-ruído, aumento da área de recepção do transdutor, simplificação da construção do transdutor, simplificação do circuito de demodulação/ processamento, e maior isolação entre os circuitos de transmissão e recepção de sinais. Na fase inicial, o circulador ativo proposto é modelado por equacionamento, utilizando-se tanto o modelo ideal dos amplificadores operacionais como o seu modelo de resposta em frequência. Simulações computacionais foram executadas para confirmar a validade do equacionamento. Um circuito montado em placa de prototipagem rápida foi apresentado, e testes de prova de conceito em baixas frequências foram realizados, mostrando uma grande semelhança entre o teórico, o simulado e o experimental. A segunda parte contou com o projeto do circuito circulador para a operação em maiores frequências. O circuito proposto é composto por três amplificadores operacionais de realimentação por corrente e vários componentes passivos. Uma análise de sensibilidade utilizando os métodos de Monte-Carlo e análise do pior caso foi aplicada, resultando em um perfil de comportamento frente às variações dos componentes do circuito e às variações da impedância de carga. Uma placa de circuito impressa foi projetada, utilizando-se de boas práticas de leiaute para a operação em altas frequências. Neste circuito montado, foram realizados os seguintes testes e medições: comportamento no domínio do tempo, faixa dinâmica, nível de isolação em relação à amplitude do sinal, largura de banda, levantamento dos parâmetros de espalhamento, e envio e recepção de sinais por transdutor de ultrassom Doppler de ondas contínuas. Os resultados dos testes de desempenho foram satisfatórios, apresentando uma banda de transmissão de sinais para frequências de 100 MHz, isolação entre portas não consecutivas de 39 dB na frequência de interesse para ultrassom Doppler e isolação maior que 20 dB para frequências de até 35 MHz. A faixa dinâmica excedeu a tensão de 5 Vpp, e o circuito teve bom comportamento no envio e na recepção simultânea de sinais pelo transdutor de ultrassom. / Traditional circulators are widely used in both telecommunications and military defense for sending and receiving signals simultaneously through a single medium. These passive circuits which are manufactured from ferromagnetic materials, have the disadvantages of having suffered an increase in dimensions, weight, and manufacturing costs along with the decrease in the operation frequency established in the designs of such devices, thus preventing their useful employment in frequencies below 500 MHz. The active circulator emerged as an alternative to the traditional ones, and has applications on frequencies ranging from a DC level to levels involving dozens of gigahertz. It is applicable when compact devices are made necessary, at a low cost, and for low frequencies. The first circuits to be introduced had a major limitation in terms of operating frequency and power delivered to the load. However, due to technological advances in electronics, problems such as the aforementioned can now be minimized. This research work presents the development of an active circulator circuit to be used in electronic instrumentation, particularly for operation at frequencies such as those used in continuous wave Doppler ultrasound equipment, ranging from 2 MHz to 10 MHz. The advantages made possible by implementing ultrasound systems with circulators are related to an increase in the signal-to-noise ratio, an increase in the transducers reception area, a simplified construction of the transducer, simplification of the demodulation/processing circuit, and a greater isolation between the transmission circuits and signal reception. In the initial phase, the proposed active circulator was modeled by means of an equating method, using both the ideal model of operational amplifiers and the model of frequency response. Computer simulations were carried out in order to confirm the validity of the equating method. A circuit mounted upon a breadboard was introduced and proof of concept assessments were performed at low frequencies, showing a great similarity among the theoretical, simulated and experimented data. The second phase is when the circulator circuits design was developed in order make its operation at higher frequencies possible. The proposed circuit is comprised of three currentfeedback operational amplifiers and several passive components. A sensitivity analysis was carried out using Monte-Carlo methods and worst-case analyses, resulting in a certain behavioral profile influenced by variations in circuit components and variations in load impedance. A printed circuit board was designed, employing good practice layout standards so that operation at high frequencies would be achieved. The following evaluations and measurements were performed on the circuit that was assembled: time domain behavior, dynamic range, isolation level relative to signal amplitude, bandwidth, survey of the scattering parameters, and transmission and reception of signals by a continuous wave Doppler ultrasound transducer. The results of the performance tests were satisfactory, presenting a 100 MHz signal transmission band, isolation between non-consecutive ports of 39 dB at the frequency of interest to the Doppler ultrasound, and an isolation greater than 20 dB for frequencies of up to 35 MHz. The dynamic range exceeded the 5Vpp and the circuit performed satisfactorily in the simultaneous transmission and reception of signals through the ultrasound\'s transducer.
253

Degradação de bifenila policlorada e caracterização da comunidade microbiana de reator anaeróbio com biofilme / Studies on the biodegradation and degradation of polychlorinated biphenyl in anaerobious conditions

Corrêa, Regiane Cristina 14 October 2011 (has links)
Métodos de Microbiologia de anaeróbios estritos e de Biologia Molecular foram empregados para se conhecer a diversidade de microrganismos relacionados à degradação de ascarel em reatores anaeróbios metanogênicos. A avaliação de potencial metanogênico foi realizada para a escolha da melhor condição nutricional, bem como, para a seleção de material suporte e solvente adequado a solubilização do ascarel. Nos ensaios em batelada, a produção de metano foi maior nos reatores contendo etanol (média de 0,22 - 0,46 molCH4/gSTV, 46h). Remoção de 85,6% (86,7 mg/L de PCB em Aroclor 1016 e 1260) foi obtida na condição com espuma de poliuretano, etanol (46g/L) e formiato (680 mg/L). Diferentes solventes e surfactantes, tais como, DMSO, dioxano, ácido acético, ácido fórmico, n-hexano, acetona, etano, metanol, Tween 80, SDS (10%) e Triton X-100 foram avaliados para a solubilização de ascarel. Dentre esses, metanol, Triton X-100 e ácido fórmico foram eleitos para a realização de ensaio em reatores em batelada contendo espuma de poliuretano, com o propósito de avaliar o potencial metanogênico na degradação de PCB. Os valores de produção de metano foram muito semelhantes (0,21 0,38 molCH4/mLgSTV, 45h) nas diferentes condições, no entanto, a remoção de PCB foi maior nos reatores com metanol 790 mg/L (86,6%), ácido Fórmico 600 mg/L (84,5%) e Triton X-100 1% (72,1%). Portanto, a melhor condição foi contemplada para a operação do reator anaeróbio horizontal de leito fixo (RAHLF) no tratamento do ascarel, ou seja, células imobilizadas em espuma de poliuretano, etanol e formiato (como fonte de carbono), Triton X-100 (0,1%) e metanol (como solvente). No RAHLF, a remoção média de matéria orgânica (DQO) foi de 91% para concentração afluente média de 1270 mg/L. A presença de morfologias semelhantes à Methanosarcina e bacilos fluorescentes foi confirmada em exames microscópicos. Na análise filogenética, por meio de PCR/DGGE e seqüenciamento das bandas recortadas, os grupos encontrados foram relacionados aos Filos Proteobacteria, Firmicutes, Spirochaetes, Chlorobi e Chloroflexi, sendo que neste último estão incluídos representantes relacionados a degradação de PCBs. Dentre as arquéias metanogênicas verificou-se similaridade de 99% e 97% com Methanosaeta sp. e Methanolinea sp., relacionadas com a metanogenese acetoclástica e hidrogenotrófica, respectivamente / Molecular biology and microbiology methods were used to study the microbial communities related to degradation of ascarel at methanogenic conditions in an anaerobic reactor. The methanogenic potential was evaluated to choose the better nutritional condition as well as to select the better support material and the most suitable solvent to favor the solubilization of ascarel. The methane production was higher (0.22 0.46 molCH4/mLgSTV, 46h) in batch reactors containing ethanol (46 g/L) and formate (680 mg/L), the PCB elimination attaining 85.6% (86.7 mg/L de PCB as Aroclor 1016 and 1260) when Polyuretane foam was used as support material. Different solvents, namely DMSO, dioxane, n-hexane, acetic acid, formic acid, acetone, ethane, methanol, and surfactants, such as 10% SDS,, Triton X-100, were evaluated aiming o determine the better condition to solubilize ascarel. According to the results of such experiments, methanol, formic acid and Triton X-100 were selected for carrying out the batch experiments in reactors containing polyurethane foam to evaluate the methane production during the PCBs degradation. Regardless of the operation conditions the methane production rates were similar (0.21 0.38 molCH4/gSTV, 45h), however the elimination of PCB was higher in the reactors containing methanol (790 mg/L), formic acid (600 mg/L) and Triton X-100 (1%). Therefore, the better condition for treating ascarel-containing residues in a bench-scale horizontal-flow immobilized biomass (HAIB) was attained with cells immobilized in polyurethane foam when ethanol and formate were used as carbon sources, and in presence of Triton X-100 and methanol, the average elimination of organic material attaining 91% for affluent concentration of 1270 mg/L. The presence of Methanosarcina and fluorescent rods was confirmed by microscopy analysis. According to the filogenetics analysis, which was carried out by PCR/DGGE and band-sequencing, the Bacteria domain are related to the Filos Proteobacteria, Firmicutes, Spirochaetes, Chlorobi and Chloroflexi, this latter being directly related to the degradation of PCB. Among the methanogenic Archea, a similiraty of 99% and 97% was observed to Methanosaeta sp. and Methanolinea sp. related to acetoclastic and hydrogenthrophic methanogenesis, respectively
254

Degradação de bifenila policlorada e caracterização da comunidade microbiana de reator anaeróbio com biofilme / Studies on the biodegradation and degradation of polychlorinated biphenyl in anaerobious conditions

Regiane Cristina Corrêa 14 October 2011 (has links)
Métodos de Microbiologia de anaeróbios estritos e de Biologia Molecular foram empregados para se conhecer a diversidade de microrganismos relacionados à degradação de ascarel em reatores anaeróbios metanogênicos. A avaliação de potencial metanogênico foi realizada para a escolha da melhor condição nutricional, bem como, para a seleção de material suporte e solvente adequado a solubilização do ascarel. Nos ensaios em batelada, a produção de metano foi maior nos reatores contendo etanol (média de 0,22 - 0,46 molCH4/gSTV, 46h). Remoção de 85,6% (86,7 mg/L de PCB em Aroclor 1016 e 1260) foi obtida na condição com espuma de poliuretano, etanol (46g/L) e formiato (680 mg/L). Diferentes solventes e surfactantes, tais como, DMSO, dioxano, ácido acético, ácido fórmico, n-hexano, acetona, etano, metanol, Tween 80, SDS (10%) e Triton X-100 foram avaliados para a solubilização de ascarel. Dentre esses, metanol, Triton X-100 e ácido fórmico foram eleitos para a realização de ensaio em reatores em batelada contendo espuma de poliuretano, com o propósito de avaliar o potencial metanogênico na degradação de PCB. Os valores de produção de metano foram muito semelhantes (0,21 0,38 molCH4/mLgSTV, 45h) nas diferentes condições, no entanto, a remoção de PCB foi maior nos reatores com metanol 790 mg/L (86,6%), ácido Fórmico 600 mg/L (84,5%) e Triton X-100 1% (72,1%). Portanto, a melhor condição foi contemplada para a operação do reator anaeróbio horizontal de leito fixo (RAHLF) no tratamento do ascarel, ou seja, células imobilizadas em espuma de poliuretano, etanol e formiato (como fonte de carbono), Triton X-100 (0,1%) e metanol (como solvente). No RAHLF, a remoção média de matéria orgânica (DQO) foi de 91% para concentração afluente média de 1270 mg/L. A presença de morfologias semelhantes à Methanosarcina e bacilos fluorescentes foi confirmada em exames microscópicos. Na análise filogenética, por meio de PCR/DGGE e seqüenciamento das bandas recortadas, os grupos encontrados foram relacionados aos Filos Proteobacteria, Firmicutes, Spirochaetes, Chlorobi e Chloroflexi, sendo que neste último estão incluídos representantes relacionados a degradação de PCBs. Dentre as arquéias metanogênicas verificou-se similaridade de 99% e 97% com Methanosaeta sp. e Methanolinea sp., relacionadas com a metanogenese acetoclástica e hidrogenotrófica, respectivamente / Molecular biology and microbiology methods were used to study the microbial communities related to degradation of ascarel at methanogenic conditions in an anaerobic reactor. The methanogenic potential was evaluated to choose the better nutritional condition as well as to select the better support material and the most suitable solvent to favor the solubilization of ascarel. The methane production was higher (0.22 0.46 molCH4/mLgSTV, 46h) in batch reactors containing ethanol (46 g/L) and formate (680 mg/L), the PCB elimination attaining 85.6% (86.7 mg/L de PCB as Aroclor 1016 and 1260) when Polyuretane foam was used as support material. Different solvents, namely DMSO, dioxane, n-hexane, acetic acid, formic acid, acetone, ethane, methanol, and surfactants, such as 10% SDS,, Triton X-100, were evaluated aiming o determine the better condition to solubilize ascarel. According to the results of such experiments, methanol, formic acid and Triton X-100 were selected for carrying out the batch experiments in reactors containing polyurethane foam to evaluate the methane production during the PCBs degradation. Regardless of the operation conditions the methane production rates were similar (0.21 0.38 molCH4/gSTV, 45h), however the elimination of PCB was higher in the reactors containing methanol (790 mg/L), formic acid (600 mg/L) and Triton X-100 (1%). Therefore, the better condition for treating ascarel-containing residues in a bench-scale horizontal-flow immobilized biomass (HAIB) was attained with cells immobilized in polyurethane foam when ethanol and formate were used as carbon sources, and in presence of Triton X-100 and methanol, the average elimination of organic material attaining 91% for affluent concentration of 1270 mg/L. The presence of Methanosarcina and fluorescent rods was confirmed by microscopy analysis. According to the filogenetics analysis, which was carried out by PCR/DGGE and band-sequencing, the Bacteria domain are related to the Filos Proteobacteria, Firmicutes, Spirochaetes, Chlorobi and Chloroflexi, this latter being directly related to the degradation of PCB. Among the methanogenic Archea, a similiraty of 99% and 97% was observed to Methanosaeta sp. and Methanolinea sp. related to acetoclastic and hydrogenthrophic methanogenesis, respectively
255

中小型PCB業者因應後山寨文化經營策略之探討

張玉青 Unknown Date (has links)
近幾年由於「山寨手機」的興起,吸引了大家對於山寨產品的注意力,改變了一般民眾對山寨產品的想法,然而,山寨手機的出現,已經不單是一個社會的獨特現象,它更影響了手機產業供應鏈的生態。因此本研究透過個案研究方法,以B公司做為研究對象,從收集的初級及次級資料中,利用SWOT分析與五力分析作為分析方法,試圖回答下列兩個問題:(1)瞭解「山寨產業」對於PCB產業有何衝擊?(2)面對「山寨產業」的衰退,台灣PCB廠商應如何因應? 本研究發現,由於B公司初期的企業能力能夠滿足山寨手機的需求,因此能夠在山寨手機興起時從中獲利,然而,隨著山寨手機產業的衰退,本研究認為B公司須採用下列策略因應:(1)淡出山寨手機供應鏈,不再陷入削價競爭的窘境,將目標客戶轉為「白牌手機」廠商,(2)善用大陸市場與低價勞力,由於大陸市場已經從「世界工廠」轉變為「世界市場」,為了服務廣大的消費者,國際大廠紛紛在大陸設立據點,因此B公司應繼續增加昆山廠的生產線,同時,(3)要提高手機用PCB的研發費用,由於傳統山寨手機產業已經衰減,新的需求轉向高階智慧型手機,因此B公司必須手機產品主力從低階四層板,提升為高階的HDI板,除了可以回應智慧型手機的需要外,也慢慢將目標客戶轉移至品牌手機廠商。 本研究主要貢獻是提供企業深入了解山寨手機對手機產業供應鏈之影響,雖然仿冒抄襲是一個新興產業成長的必經之路,然而大陸的山寨手機產業所產生的影響不容小覷,因此本研究以一個曾經受惠於在山寨手機的PCB廠作為研究對象,試圖提出面對後山寨時代的來臨,企業應該用如何回應。 / The rise of bandit mobile phone industry has attracted people’s eye and change people’s mind on bandit products. “Bandit” is not just a unique social phenomenon, but an impact on the outside environment of mobile phone supply chain. This research used case study to investigate the B company, a Taiwanese PCB company as our research object. We utilized SWOT analysis and Porter’s five force analysis as tools with our primary and secondary data to clarify the following two questions: (1) what the influence did bandit industry arise on the PCB industry, and (2) what is the PCB company’s strategy when facing downturn of the bandit mobile phone industry. Our study has found that the B company’s capability matched the need of bandit mobile phone industry at the early stage. However, with the industry declined, we suggest the B company should adapt the following strategies in order to maintain its profit: (1) fade out from bandit mobile phone industry, and turn to white-box mobile phone industry; (2) take advantage of cheap labor cost in China and extend existing production lines; (3) enhance the R&D investment on mobile phone PCB. The major contribution of this research is to help firms understand the influence of bandit mobile phones on mobile phone’s supply chain. Although copy is the necessary evil in the developing industry, however, the impact from it still can’t be ignored. We choose a Taiwanese PCB company, which has been benefited from bandit mobile phones, as our case to identify what’s next for the PCB companies in post bandit mobile phone age.
256

Modélisaton et conception de transformateurs planar pour convertisseur de puissance DC/DC embarqué / Modeling and design of planar trasnformers for embedded DC/DC power converter

Ngoua teu Magambo, Jean-Sylvio 13 December 2017 (has links)
Ces travaux de thèse s’inscrivent dans la problématique de développement de transformateurs planar pour l’intégration de puissance, dans le contexte de l’avion plus électrique (More Electric Aircraft – MEA) où les contraintes de volume et de poids sont primordiales. Les composants magnétiques restent en effet un frein à l’intégration des systèmes d’Electronique de Puissance et les composants planar (transformateurs et inductances) offrent une alternative intéressante aux composants bobinés pour la réduction de la taille des convertisseurs.Dans ce manuscrit, des méthodes, un outil de dimensionnement et des prototypes de transformateurs planar (2 et 3 enroulements) en technologie feuillard et PCB sont développés pour des applications de convertisseur DC/DC aéronautique. Dans un premier temps, les modèles permettant le calcul des pertes, l'estimation de l'élévation de température et le calcul de l’inductance de fuite sont présentés et comparés afin de concevoir des outils de calculs pour la conception. Dans un deuxième temps, il est montré que la modification de la forme des angles des spires rectangulaires permet de réduire significativement les pertes cuivre HF. Sur la base de ces outils et résultats, des prototypes de transformateurs planar à 3 enroulements en PCB multicouches sont développés. De nombreux prototypes sont caractérisés et valident les modèles de dimensionnement proposés. Enfin, l’un de ces prototypes est intégré et testé dans un convertisseur de puissance DC/DC de 3.75kW mettant en évidence les gains obtenus. / These thesis works deal with the issue of the planar transformers development for power integration, in the context of the More Electric Aircraft (MEA), where the constraints of volume and weight are paramount. Magnetic components remain a hindrance to the integration of Power Electronics systems and planar components (transformers and inductors) offer an interesting alternative to wound components for reducing the size of converters.In these works, methods, a sizing tool and prototypes of planar transformers (2 and 3 windings) in strip and PCB technology are developed for aeronautical DC / DC converter applications. Firstly, the models allowing the calculation of the losses, the estimation of the temperature rise and the calculation of the leakage inductance are presented and compared in order to design calculation tools for engineers. In a second step, it is shown that the modification of the shape of the angles of rectangular turns makes it possible to significantly reduce the HF copper losses.Based on these tools and results, prototypes of 3-windings planar transformers in multilayer PCBs are developed. Many prototypes are characterized and validate the proposed designing models. Finally, one of these prototypes is integrated and tested in a DC / DC power converter of 3.75kW highlighting the gains obtained.
257

BIFENILOS POLICLORADOS (PCBs) EM PESCADOS IN NATURA DO LITORAL DO RIO GRANDE DO SUL, BRASIL / POLYCHLORINATED BIPHENYLS (PCBs) IN FISH IN NATURA FROM THE COAST OF RIO GRANDE DO SUL, BRAZIL

Pigatto, Giane Magrini 05 August 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Polychlorinated biphenyls (PCBs) are toxic, non-biodegradable, and lipophilic chemical compounds of industrial origin. In Brazil, PCBs are still used in old electrical transformers and capacitors which were installed up to 1981 when their use and commercialization were banned. However, the permission to use devices with PCBs installed up to the early 80s was maintained up to the moment that their dielectric fluids or the entire device be fully replaced for products free of PCBs. Currently, PCBs are classified as persistent organic pollutants (POPs) because they pollute and accumulate in the environment affecting all organisms in the food chain. The main form of human intake is the ingestion of contaminated food, especially food of animal origin. Fish are the main means of transmission of PCB congeners to the human body. The concern about PCBs is centered on their toxicological potential, especially as inducers of cancer. Thus, the aim of this study was to investigate the possible contamination by residues of 11 individual PCB congeners in fresh marine fish from the state of Rio Grande do Sul (RS), Brazil. The methodology for the analysis of PCBs in fish included sampling on the coast of RS, the extraction and purification of these compounds by the use of acidified silica gel and solvents, as well as their identification and quantification using gas chromatography coupled to a micro electron capture detector (GC - μECD). Results were confirmed by gas chromatography coupled to mass spectrometry (GC - MS). PCBs investigated were not found in all samples. PCBs 28 and 52 were not detected. PCBs 153, 138, 180, 118, 101, 77, and 81 were found in 98.33 %, 95%, 93.33%, 60%, 33.33 %, and 31.67 % of the samples, respectively. PCBs 126 and 169 were found at lower frequencies, 18.33% and 15%, respectively. The individual congeners found in higher mean concentrations were PCB 153 (184.36 ng/g fat), followed by PCB 138 (159.27 ng/g fat), PCB 118 (98.16 ng/g fat), PCB 180 (69.04 ng/g fat), PCB 101 (32.99 ng/g fat), and PCB 77 (12.95 ng/g fat). PCBs 81, 126 and 169 were found in lower concentrations (4.97 ng/g, 4.49 ng/g and 2.08 ng/g fat, respectively). Results confirm the contamination by PCBs of all marine species of consumption analyzed and can be used as indicators of environmental contamination by these compounds in the coast of RS. / Bifenilos policlorados (PCBs) são compostos químicos de origem industrial, tóxicos, não biodegradáveis, lipofílicos, e que foram produzidos a partir da década de 30 até os anos 70, quando foram proibidos. No Brasil, PCBs estão presentes, por exemplo, em transformadores e capacitores elétricos instalados até 1981, quando a comercialização e utilização desses compostos foram proibidas no país. Porém, manteve-se a permissão de utilização desses equipamentos contendo PCBs e instalados até o início dos anos 80, até que ocorra a substituição integral dos mesmos ou a troca de seus respectivos fluidos dielétricos por produtos isentos de PCBs. Atualmente, PCBs são classificados como poluentes orgânicos persistentes (POPs), pois poluem e se acumulam no meio ambiente, influenciando todos os organismos da cadeia alimentar. A principal forma de contaminação humana é a ingestão de alimentos contaminados, principalmente alimentos de origem animal. Dentre esses, os pescados constituem-se no principal meio de veiculação de congêneres de PCBs até o organismo humano. A preocupação acerca dos PCBs está centrada no seu potencial toxicológico, principalmente como indutores de câncer. Diante disso, o objetivo desse trabalho foi investigar a possível contaminação, por resíduos de 11 congêneres individuais de PCBs, em pescados marinhos in natura do estado do Rio Grande do Sul, Brasil. A metodologia empregada para análise de PCBs nos pescados incluiu a coleta de amostras do litoral do RS, a extração e purificação desses compostos com a utilização de sílica gel acidificada, solventes e, finalmente, a identificação e quantificação dos mesmos utilizando-se cromatografia gasosa acoplada a um micro detector de captura de elétrons (GC-μECD). Os resultados obtidos foram confirmados por cromatógrafo gasoso acoplado à espectrometria de massas (GC-MS). Os PCBs investigados não foram encontrados em todas as amostras analisadas. Os PCBs 28 e 52 não foram detectados. O PCB 153 foi encontrado em 98,33% das amostras analisadas, seguido pelos PCBs 138 e 180 encontrados em 95% das amostras, pelo PCB 118 encontrado em 93,33% das amostras, pelo PCB 101 encontrado em 60% das amostras, pelo PCB 77 e PCB 81, encontrados em 33,33% e 31, 67% das amostras, respectivamente. Os PCBs 126 e 169 foram encontrados com menores freqüências, 18,33% e 15%, respectivamente. Os congêneres individuais encontrados em maiores concentrações médias foram o PCB 153 (184,36 ng/g de gordura), seguido pelo PCB 138 (159,27 ng/g de gordura), PCB 118 (98,16 ng/g de gordura), PCB 180 (69,04 ng/g de gordura), PCB 101 (32,99 ng/g de gordura) e PCB 77 (12,95 ng/g de gordura). Os PCBs 81, 126 e 169 foram encontrados nas menores concentrações (4,97 ng/g, 4,49 ng/g e 2,08 ng/g de gordura, respectivamente). Os resultados obtidos confirmam a contaminação por PCBs de todas as espécies marinhas de consumo analisadas e podem ser utilizados como indicativos da contaminação ambiental, por esses compostos, no litoral do RS.
258

Resíduos de pesticidas organoclorados e bifenilos policlorados em sedimentos e algas de Santos e Cananéia, SP, Brasil / Waste of organochlorine pesticides and polychlorinated biphenyls in sediments and algae of Santos and Cananéia- SP Brazil

Maria Auxiliadora Costa Matos 03 December 2002 (has links)
Bifenilos policlorados (PCBs) e pesticidas organoclorados são poluentes resistentes à degradação e têm sido identificados em vários compartimentos do ambiente marinho. O objetivo deste trabalho foi otimizar e validar a metodologia, e avaliar a contaminação por pesticidas organoclorados e PCBs em algas e sedimentos costeiros no Estuário e Baía de Santos-São Vicente e no Complexo Estuarino-Lagunar de Iguape e Cananéia (SP). Foram coletadas nessas regiões um total de 37 amostras de sedimento superficial, 3 testemunhos com 27 sub-amostras e 10 amostras de alga, no período de 1998-2001. O método, que incluiu a extração e purificação com solventes orgânicos e análise por GC-ECD, mostrou-se satisfatório dentro dos padrões internacionais. Na região de Cananéia-Iguape predominaram os DDTs (sedimentos: 0,78 a 14,52 ng.g-1 peso seco) e as maiores concentrações ocorreram nas proximidades da Cidade de Cananéia e Baía de Trapandé. Na região de Santos predominaram os PCBs (sedimentos: 4,08 a 133,42 ng.g-1 peso seco, testemunhos de sedimentos: 3, 70 a 44,65 ng.g-1 peso seco e algas: 15,83 a 43,21 ng.g-1 peso seco) e os maiores valores foram encontrados no emissário submarino, no Estuário de Santos, em locais próximos as indústrias, e no Estuário de São Vicente. De maneira geral, as concentrações tanto de PCBs quanto de pesticidas organoclorados em Santos e Cananéia-Iguape foram baixas. Santos apresentou maior incidência de PCBs, provavelmente devido à industrialização, enquanto que em Cananéia-Iguape predominaram os pesticidas organoclorados, que podem ser atribuídos às antigas campanhas de saúde pública ou aplicações nas lavouras. / Polychlorinated biphenyls and chlorinated pesticides are degradation resistant pollutants. They have been detected in several compartments of marine environment. The objective of this study was the optimization of the methodology and the evaluation of the contamination of chlorinated pesticides and PCBs em algae and coastal sediments in the Estuary and Bay of Santos-São Vicente and in the Lagunar Complex of Iguape and Cananéia (SP). An amount of 37 samples of superficial sediment, 3 cores with 27 subsamples and 10 samples of algae was collected in the period of 1998-2001. The methodology was considered satisfactory within international standards, that includes extraction and clean up with organic solvents and analysis with GC-ECD. In the Cananéia-Iguape region, DDTs were predominant and the highest levels were found around the city of Cananéia and in Trapandé Bay. In the Santos area, the PCBs were predominant and the highest values were found around the Santos Bay outfall and in the Estuary of Santos-São Vicente. In general, either the concentrations of PCBs or chlorinated pesticides in Santos and Cananéia-Iguape were low. Santos presented higher incidence of PCBs, probably due to industrialization, while in Cananéia-Iguape the chlorinated pesticides predominated, and that can be attributed to past public health campaigns or to agricultural uses.
259

Projeto e análise de aplicações de circuladores ativos para a operação em frequências de ultrassom Doppler de ondas contínuas / Design and application analysis of active circulators for operation in frequencies of continuous-wave Doppler ultrasound

Tales Roberto de Souza Santini 11 July 2014 (has links)
Os circuladores tradicionais são amplamente utilizados em telecomunicações e defesa militar para o simultâneo envio e recepção de sinais por um único meio. Esses circuitos passivos, fabricados a partir de materiais ferromagnéticos, possuem a desvantagem do aumento de dimensões, peso e custos de fabricação com a diminuição da frequência de operação definida no projeto destes dispositivos, inviabilizando sua aplicação em frequências abaixo de 500 MHz. O circulador ativo surgiu como uma alternativa aos tradicionais, tendo aplicações em frequências desde o nível DC até a ordem de dezenas de gigahertz. As suas maiores aplicações ocorrem quando são necessários dispositivos compactos, de baixo custo e de baixa potência. Os primeiros circuitos propostos possuíam uma grande limitação em termos de frequência de operação e de potência entregue à carga. Entretanto, com os avanços tecnológicos na eletrônica, tais problemas podem ser amenizados atualmente. Neste trabalho é apresentado o desenvolvimento de um circuito circulador ativo para a utilização em instrumentação eletrônica, em particular para a operação em frequências na ordem das utilizadas em equipamentos de ultrassom Doppler de ondas contínuas, na faixa de 2 MHz a 10 MHz. As possíveis vantagens da implementação de circuladores em sistemas de ultrassom estão relacionadas ao incremento da relação sinal-ruído, aumento da área de recepção do transdutor, simplificação da construção do transdutor, simplificação do circuito de demodulação/ processamento, e maior isolação entre os circuitos de transmissão e recepção de sinais. Na fase inicial, o circulador ativo proposto é modelado por equacionamento, utilizando-se tanto o modelo ideal dos amplificadores operacionais como o seu modelo de resposta em frequência. Simulações computacionais foram executadas para confirmar a validade do equacionamento. Um circuito montado em placa de prototipagem rápida foi apresentado, e testes de prova de conceito em baixas frequências foram realizados, mostrando uma grande semelhança entre o teórico, o simulado e o experimental. A segunda parte contou com o projeto do circuito circulador para a operação em maiores frequências. O circuito proposto é composto por três amplificadores operacionais de realimentação por corrente e vários componentes passivos. Uma análise de sensibilidade utilizando os métodos de Monte-Carlo e análise do pior caso foi aplicada, resultando em um perfil de comportamento frente às variações dos componentes do circuito e às variações da impedância de carga. Uma placa de circuito impressa foi projetada, utilizando-se de boas práticas de leiaute para a operação em altas frequências. Neste circuito montado, foram realizados os seguintes testes e medições: comportamento no domínio do tempo, faixa dinâmica, nível de isolação em relação à amplitude do sinal, largura de banda, levantamento dos parâmetros de espalhamento, e envio e recepção de sinais por transdutor de ultrassom Doppler de ondas contínuas. Os resultados dos testes de desempenho foram satisfatórios, apresentando uma banda de transmissão de sinais para frequências de 100 MHz, isolação entre portas não consecutivas de 39 dB na frequência de interesse para ultrassom Doppler e isolação maior que 20 dB para frequências de até 35 MHz. A faixa dinâmica excedeu a tensão de 5 Vpp, e o circuito teve bom comportamento no envio e na recepção simultânea de sinais pelo transdutor de ultrassom. / Traditional circulators are widely used in both telecommunications and military defense for sending and receiving signals simultaneously through a single medium. These passive circuits which are manufactured from ferromagnetic materials, have the disadvantages of having suffered an increase in dimensions, weight, and manufacturing costs along with the decrease in the operation frequency established in the designs of such devices, thus preventing their useful employment in frequencies below 500 MHz. The active circulator emerged as an alternative to the traditional ones, and has applications on frequencies ranging from a DC level to levels involving dozens of gigahertz. It is applicable when compact devices are made necessary, at a low cost, and for low frequencies. The first circuits to be introduced had a major limitation in terms of operating frequency and power delivered to the load. However, due to technological advances in electronics, problems such as the aforementioned can now be minimized. This research work presents the development of an active circulator circuit to be used in electronic instrumentation, particularly for operation at frequencies such as those used in continuous wave Doppler ultrasound equipment, ranging from 2 MHz to 10 MHz. The advantages made possible by implementing ultrasound systems with circulators are related to an increase in the signal-to-noise ratio, an increase in the transducers reception area, a simplified construction of the transducer, simplification of the demodulation/processing circuit, and a greater isolation between the transmission circuits and signal reception. In the initial phase, the proposed active circulator was modeled by means of an equating method, using both the ideal model of operational amplifiers and the model of frequency response. Computer simulations were carried out in order to confirm the validity of the equating method. A circuit mounted upon a breadboard was introduced and proof of concept assessments were performed at low frequencies, showing a great similarity among the theoretical, simulated and experimented data. The second phase is when the circulator circuits design was developed in order make its operation at higher frequencies possible. The proposed circuit is comprised of three currentfeedback operational amplifiers and several passive components. A sensitivity analysis was carried out using Monte-Carlo methods and worst-case analyses, resulting in a certain behavioral profile influenced by variations in circuit components and variations in load impedance. A printed circuit board was designed, employing good practice layout standards so that operation at high frequencies would be achieved. The following evaluations and measurements were performed on the circuit that was assembled: time domain behavior, dynamic range, isolation level relative to signal amplitude, bandwidth, survey of the scattering parameters, and transmission and reception of signals by a continuous wave Doppler ultrasound transducer. The results of the performance tests were satisfactory, presenting a 100 MHz signal transmission band, isolation between non-consecutive ports of 39 dB at the frequency of interest to the Doppler ultrasound, and an isolation greater than 20 dB for frequencies of up to 35 MHz. The dynamic range exceeded the 5Vpp and the circuit performed satisfactorily in the simultaneous transmission and reception of signals through the ultrasound\'s transducer.
260

Local and global contaminants in Swedish waters : studies on PCBs, DDTs, 4,5,6-trichloroguaiacol and their transformation products in fish and sediments

Söderström, Maria January 2002 (has links)
This thesis is focused on studies on the environmental fate and methodological improvements for determination of the global contaminants, PCBs and DDTs, and locally discharged phenolics, e.g. 4,5,6-trichloroguaiacol (4,5,6-TCG), and their transformation products. 4,5,6-TCG is released from bleached pulp mills, and was chosen as a model substance, to study its fate and effects in aquatic environments. In a brackish water model ecosystem, 4,5,6-TCG was shown to be transformed via demethylation, dechlorination, and methylation reactions. Marine periphyton exposed to 4,5,6-TCG was shown to form demethylated, brominated and dimeric metabolites. Several of these metabolites were identified and quantified. Also more tightly bound chlorophenolics were recovered from the substrate, after harsh extraction procedures had been applied. Conjugates of chlorophenols in fish bile were determined as useful tracers for monitoring effluents from bleached pulp mills, even in areas far from the discharge point. To facilitate calculations of water concentrations, bile to water bioconcentration factors (bBCF-values) were determined for several phenolics, including also alkali-labile chlorocatechols. PCBs and DDTs, were assessed in Swedish lakes with background exposure of these global contaminants. A methodological study focus on the contamination risks of airborne PCBs, during freeze-drying and storage of dry sediment samples. Eutrophication has been proposed to cause lower levels of pollutants in biota in lakes due to biomass dilution but in this thesis examples of higher levels of PCBs in sediment traps, sediment and in perch, and also in higher fluxes of PCBs to the sediment, were observed. Phytoplankton are supposed to be responsible for most of the transport of the contaminants. The composition of DDTs in soil, sediment traps and in dated sediment cores was studied in some detail. PCBs, DDTs, HCB and HCHs were measured in sediments from 100 reference lakes included in the National Swedish Environmental Program. The lakes have a large variation in lake characteristics, representative for different areas in Sweden. A gradient was observed for sPCB with decreasing levels from the south west towards the north. The results suggests that longrange transport is the dominating mechanism for distribution of the contaminants analysed. In this study the levles of PCBs and DDTs were lower in eutrophic lakes than in oligotrophic lakes, in an area with similar atmospheric exposure. / <p>At the time of the doctoral defense, the following papers were unpublished and had a status as follows: Paper 4: Submitted. Paper 6: Manuscript.</p>

Page generated in 0.0814 seconds