• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 2
  • Tagged with
  • 9
  • 7
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Primärenergianvändning av passivhus i Sverige : Med fokus på Kvarteret Trettondagen

Jiang, Jia January 2013 (has links)
The building sector accounted for around a fourth of the total energy usage in Sweden in year 2010 (Energimyndigheten, 2012). Therefore it has become very interesting to achieve a lower energy usage in residential buildings. One way to achieve that is to build so called passive houses. By being very well insulated and have low leakage through the walls, they can reduce the energy usage for heating with a substantial amount. The first passive house was built during the 90’s in Germany; and in Sweden the first passive house was built in Gothenburg 2001. Both Sweden and EU have goals to reduce the overall energy usage and greenhouse emission by 2020 and 2050. The concept of the passive house is one way to achieve the goals. In short, the concept of the passive house in Sweden is: The air tightness for the walls should be tighter than 0,3 l/m2,s at 50 Pa overpressure The heat loss factor must not exceed 15 W/m2 Atemp for climate zone III The delivered energy must not exceed 50 kWh/m2 Atemp,year for purely non electrically heated systems in climate zone III The average u-value for windows should be as highest 0,8 W/m2,K. The term primary energy is a term that is frequently used in the EU when talking about energy usage. Apart from the above mentioned criteria, passive houses in Germany must also use less than 120 kWh/m2Atemp,year in primary energy. Primary energy usage for the passive houses is calculated by multiplying the energy usage with the respective primary energy factor. The primary energy factors were set to be the following: Electricity mix – 2,7 District heating mix – 0,79 District heating from waste – 0,04 Electricity from wind power – 0,05 The results show that the passive houses in Trettondagen and Oxtorget were the only ones that passed the German limit of 120 kWh/m2Atemp,year. The low energy usage in Trettondagen could be explained by the fact that the input values for calculating primary energy usage were simulated and not measured. Moreover, the passive house in Trettondagen was connected to the district heating from waste, which has a very low primary energy factor. The passive houses in Oxtorget were not connected to district heating and relied only on solar panels and heat recovery in the ventilation unit. An electric heater was installed in both the ventilation unit and the storage tank to provide extra heating. What set the passive house in Oxtorget apart from the others was that the electricity used in the houses only came from wind power. The low primary energy factor for wind power contributed to the extremely low primary energy of Oxtorget. The domestic electricity was relatively high in most of the passive houses, a reason to why they had problem with passing the German limit. One house had low enough domestic electricity usage to possibly pass the limit if the source of energy for heating was changed. It was the passive house in Falkenberg which was connected to district heating from biofuels (1,035). By switching to district heating from waste instead, the passive house in Falkenberg will then pass the limit. Primary energy usage for the passive houses in Oxtorget was also calculated with one half from electricity mix and the other half from electricity from wind power. Despite a large increase in primary energy, the passive houses still passed the limit. The passive house in Trettondagen was also calculated with switching district heating from waste to district heating mix. The primary energy increased a little bit but remained under the limit. The conclusion form this thesis showed that certain passive houses in Sweden were able to fall beneath the German limit for primary energy. One obstacle could be the high domestic electricity that has to decrease, perhaps by informing and involving the residents. Another problem is the absence of proper framework for calculating primary energy. There are some calculations mentioned in FEBY that resembles calculations for primary energy. The definitions though are too unclear and thus difficult to compare with the German standard.
2

Jämförelse av fjärrvärme och bergvärme, kompletterad med solceller i Helsingborg

Lindberg, Alexander January 2014 (has links)
En studie över jämförelsen av fjärrvärme i Helsingborg och bergvärme har utifrån resursutnyttjande, klimatpåverkan och ekonomi genomförts. Till detta har scenarion med solcellsanläggningar som komplement till bergvärmesystemet jämförts. Genom att förbruka fjärrvärme istället för bergvärme så skulle ett Nils Holgersson hus under 2013 förbruka 25 MWh mindre primärenergi, vilket mostsvarar 2 ton råolja och 5 ton pellets. Det billigaste bergvärmesystemet i studien hade en årskostnad på 9 000 kr mer än fjärrvärmen. Beroende på ursprungsmärkningen av elen utnyttjad i bergvärmesystemet variera koldioxid resultatet. Men utifrån nordisk residualmix så minskas utsläppen av koldioxid med minst 4 ton per år med fjärrvärme som uppvärmninsgalternativ.
3

Miljökonsekvenserna av Växjö kommuns energikrav på bostäder på Östra Lugnet

Johansson, Martina, Petersson, Johanna January 2013 (has links)
I detta examensarbete studeras miljökonsekvenser av Växjö kommuns ställda energikrav på bostadsområdet Östra Lugnet i Växjö. Dessutom studeras hur väl Växjö kommuns och BBRs (Boverkets byggregler) krav på specifik energianvändning efterlevs. Växjö kommuns krav ställs på både företag och privatpersoner där kravet innefattar anslutning till Växjös fjärrvärmenät. Kommunen ställer också krav på företag gällande specifik energianvändning.   Denna studie uppvisar skillnader, både mellan företag och privatpersoner men även mellan företags olika kvarter, i hur väl ställda energikrav efterlevs. Där lyckas företagen sämst, trots att de haft strängare krav.   Studien visar också att fjärrvärme bidrar till en minskning av koldioxidutsläpp, vilket stöder Växjö kommuns kravställande på fjärrvärmeanslutning.
4

Resurseffektiv energieffektivisering av flerbostadshus : Frånluftsvärmepumpar i kombination med fjärrvärme / Resource efficient energy measures of apartment buildings : Exhaust air heat pumps in combination with district heating

Gustafsson, Olle, Karlsson, Johan January 2015 (has links)
Fjärrvärme täcker i dagsläget cirka 56 procent av energibehovet för uppvärmning och varmvatten i svenska bostadssektorn. Denna siffra förväntas minska i och med ökade energieffektiviseringsåtgärder och installationer av alternativa värmekällor. Det har blivit allt vanligare att både fastighetssektorn och olika miljöklassningssystem fokuserar på att minska mängden inköpt energi och ett sätt att göra detta på är att installera frånluftsvärmepumpar som ett komplement till fastighetens primära uppvärmningssystem. Det kommunalägda bostadsbolaget AB Stångåstaden planerar att utföra detta i flerbostadshus där FTX-system av flera anledningar inte är möjligt att installera. Installationen är aktuell i fastigheter som i dagsläget har frånluftsventilation och självdrag samt är högre än tre våningar.Installationen kommer att påverka den lokala fjärrvärmeleverantören Tekniska verken AB och då även de är kommunalägda finns det ett intresse i att utreda de effekter som frånluftsvärmepumparna kommer att ha på de båda företagen samt på kommunen i stort. Därför ämnar denna rapport till att påvisa effekterna av installationen av frånluftsvärmepumpar som komplement till fjärrvärme ur ett ekonomiskt, miljö- och resursmässigt perspektiv. I den här rapporten syftar resurs till den primärenergianvändning som sker till följd av förändrad fjärrvärme- och elanvändning vid installation av frånluftsvärmepumpar.Detta har gjorts genom att undersöka två befintliga fastigheter där frånluftsvärmepumpar nyligen installerats och modellera dem i programmet BV2. Där undersöks hur värmeanvändningen förändras då frånluftsvärmepumpen tillåts att drivas utifrån följande sex driftfall; 1. Frånluftsvärmepumpen går året runt 2. Frånluftsvärmepumpen går mellan december och februari 3. Frånluftsvärmepumpen går mellan oktober och april 4. Frånluftsvärmepumpen startar då utetemperaturen understiger -4˚C 5. Frånluftsvärmepumpen startar då utetemperaturen understiger +1˚C 6. Frånluftsvärmepumpen startar då utetemperaturen understiger +5˚C Dessa är framtagna med avseende på Tekniska verkens säsongsbaserade fjärrvärmepris samt på ungefärliga utetemperaturer då marginalproduktionen för fjärrvärmen skiftar bränsle. Dessa kommer även att jämföras med ett referensfall då enbart fjärrvärme täcker fastigheternas värmebehov.Förändringen i fastigheternas fjärrvärmebehov simulerades sedan i Tekniska verkens energiplaneringssystem för att se hur värme- och elproduktionen påverkades. Genom detta erhölls underlag för att kunna ta fram de ekonomiska, miljö- och primärenergimässiga effekterna som uppkommer i och med frånluftsvärmepumpens drift.Utifrån detta kan det konstateras att frånluftsvärmepumpar inte är en lönsam energieffektiviseringsåtgärd för Tekniska verken, Stångåstaden eller Linköpings kommun. Prisbilden och bränslesammansättningen för fjärrvärme i Linköping ger inte frånluftsvärmepumparna potential till att vara lönsam utifrån något av de tre kriterierna ekonomi, miljö och resurs. De mest fördelaktiga driftfallen fås för alla parter då frånluftsvärmepumpen får starta mellan en och minus fyra grader. Detta ger som bäst kommunen en ekonomisk förlust på cirka 1,6 Mkr för Fastighet A och 2,8 Mkr för Fastighet B över en tidsperiod på tjugo år, vilket bedöms vara värmepumpens ekonomiska livslängd. Förlusten beror till störst del på de höga investeringskostnaderna som frånluftsvärmepumparna medför, men också på den prisbild som är satt för fjärrvärme i Linköping.Genom att temperaturstyra frånluftsvärmepumpen ges också störst potential till att minska utsläppsintensiv marginalproduktion av fjärrvärme och genom det också ge minskade globala växthusgasutsläpp i jämförelse med att enbart använda fjärrvärme. Merparten av driftfallen ger dock ökade utsläpp i jämförelse med referensen. Anledningen är till stor del den höga andel avfallsbränsle som finns i Tekniska verkens produktionsmix. Minskad fjärrvärmeproduktion minskar även Tekniska verkens elproduktion vilken antas täckas upp av en mer utsläppsintensiv europeisk marginalproduktion.iiDet finns inget av de valda driftfallen som minskar användningen av den primärenergi som krävs vid värmeproduktionen och anledningen är återigen att den ökade elanvändningen värderas med en högre faktor än vad avfallsbaserad fjärrvärme gör.Frånluftsvärmepumparna är på båda fastigheterna installerade på fastighetens radiatorretur och trots den bevisat förhöjda returtemperaturen som sker på fjärrvärmenätet så bedöms detta inkopplingsalternativ som det mest effektiva sätt att utföra installationen på för att erhålla bäst värmefaktor, driftkostnad och grundinvestering.Trots att inget av de analyserade driftfallen gav en entydig förbättring ur kriterierna ekonomi, miljö och resurs i jämförelse med referensfallet lyckades ändå mängden inköpt energi minskas i samtliga fall. Detta kan ses som en indikation på att de mål om minskad inköpt energi som sätts inom branschen kan behöva revideras, då exempelvis en av de primära anledningarna till dessa mål är att minska koldioxidutsläppen.
5

Influences from Building Energy Efficiency Refurbishment on a Regional District Heating System

Lidberg, Tina January 2018 (has links)
Improving energy performance of existing buildings is an important part in decreasing energy use and in turn reduce the greenhouse gas emissions caused by human activity and the primary energy use. To be able to evaluate how energy refurbishment influences the greenhouse gas emissions and the primary energy use a wider system perspective is needed that puts the building in its context. This thesis deals with energy refurbishment packages performed on multi-family buildings within district heated areas and how they influence greenhouse gas emissions and primary energy use when the district heating use is altered. A simulated building is used to evaluate several energy refurbishment packages. The results are used as input data for models of district heating systems to cost optimize the district heating production. The results from the cost optimization are used to evaluate the impact on greenhouse gas emissions and primary energy use. The results show a difference between measures that saves district heating without increasing the use of electricity and measures that increases the use of electricity while district heating is saved. For example, a building refurbishment package including only building envelope improvements saves the same amount of district heating as a package including only mechanical ventilation with heat recovery. Despite this, the emissions of greenhouse gases and the use of primary energy is to a greater extent reduced in the first package because the use of electricity remains unchanged. Comparing energy refurbishment packages performed on the same building, but within different district heating systems, show the importance of the design of the district heating system. Depending on the fuel types used and to which extent electricity is co-produced in the district heating system, the results of implementing the energy refurbishment packages vary. The largest reduction of greenhouse gases and primary energy use occurs when a refurbishment package is performed on a building in a district heating system with high share of biofuel and no electricity production. / Att förbättra energiprestanda hos befintliga byggnader är en viktig del i arbetet med att minska energianvändningen och i sin tur minska utsläpp av växthusgaser orsakade av mänsklig aktivitet samt att minska användningen av primärenergi. För att kunna utvärdera hur energieffektivisering av byggnader påverkar växthusgasutsläpp och primärenergianvändning behövs ett brett systemperspektiv som sätter byggnaden i sitt sammanhang. Denna avhandling handlar om hur paket av energieffektiviseringsåtgärder som utförs på flerfamiljshus inom fjärrvärmeuppvärmda områden påverkar växthusgasutsläpp och primärenergianvändning när fjärrvärmeanvändningen förändras. Resultaten visar på skillnader mellan åtgärder som sparar fjärrvärme utan att öka användningen av el och åtgärder som ökar användningen av el medan fjärrvärme sparas. Till exempel sparar ett energieffektiviseringspaket som endast omfattar byggnadsskalsförbättringar samma mängd fjärrvärme som ett paket som endast omfattar installation av mekanisk ventilation med värmeåtervinning. Trots detta minskar utsläppen av växthusgaser och användningen av primärenergi i större utsträckning i det första paketet på grund av att elanvändningen förblir oförändrad. Vikten av fjärrvärmesystemets utformning visas då en byggnad där olika energieffektiviseringspaket testats, flyttas runt till olika fjärrvärmesystem. Beroende på vilka bränsletyper som används och i vilken utsträckning som el produceras i fjärrvärmesystemet så varierar resultaten. Den största minskningen av växthusgaser uppstår när ett renoveringspaket utförs på en byggnad i ett fjärrvärmesystem med hög andel biobränsle och ingen elproduktion.
6

Influences from Building Energy Efficiency Refurbishment on a Regional District Heating System

Lidberg, Tina January 2018 (has links)
Improving energy performance of existing buildings is an important part in decreasing energy use and in turn reduce the greenhouse gas emissions caused by human activity and the primary energy use. To be able to evaluate how energy refurbishment influences the greenhouse gas emissions and the primary energy use a wider system perspective is needed that puts the building in its context. This thesis deals with energy refurbishment packages performed on multi-family buildings within district heated areas and how they influence greenhouse gas emissions and primary energy use when the district heating use is altered. A simulated building is used to evaluate several energy refurbishment packages. The results are used as input data for models of district heating systems to cost optimize the district heating production. The results from the cost optimization are used to evaluate the impact on greenhouse gas emissions and primary energy use. The results show a difference between measures that saves district heating without increasing the use of electricity and measures that increases the use of electricity while district heating is saved. For example, a building refurbishment package including only building envelope improvements saves the same amount of district heating as a package including only mechanical ventilation with heat recovery. Despite this, the emissions of greenhouse gases and the use of primary energy is to a greater extent reduced in the first package because the use of electricity remains unchanged. Comparing energy refurbishment packages performed on the same building, but within different district heating systems, show the importance of the design of the district heating system. Depending on the fuel types used and to which extent electricity is co-produced in the district heating system, the results of implementing the energy refurbishment packages vary. The largest reduction of greenhouse gases and primary energy use occurs when a refurbishment package is performed on a building in a district heating system with high share of biofuel and no electricity production. / Att förbättra energiprestanda hos befintliga byggnader är en viktig del i arbetet med att minska energianvändningen och i sin tur minska utsläpp av växthusgaser orsakade av mänsklig aktivitet samt att minska användningen av primärenergi. För att kunna utvärdera hur energieffektivisering av byggnader påverkar växthusgasutsläpp och primärenergianvändning behövs ett brett systemperspektiv som sätter byggnaden i sitt sammanhang. Denna avhandling handlar om hur paket av energieffektiviseringsåtgärder som utförs på flerfamiljshus inom fjärrvärmeuppvärmda områden påverkar växthusgasutsläpp och primärenergianvändning när fjärrvärmeanvändningen förändras. Resultaten visar på skillnader mellan åtgärder som sparar fjärrvärme utan att öka användningen av el och åtgärder som ökar användningen av el medan fjärrvärme sparas. Till exempel sparar ett energieffektiviseringspaket som endast omfattar byggnadsskalsförbättringar samma mängd fjärrvärme som ett paket som endast omfattar installation av mekanisk ventilation med värmeåtervinning. Trots detta minskar utsläppen av växthusgaser och användningen av primärenergi i större utsträckning i det första paketet på grund av att elanvändningen förblir oförändrad. Vikten av fjärrvärmesystemets utformning visas då en byggnad där olika energieffektiviseringspaket testats, flyttas runt till olika fjärrvärmesystem. Beroende på vilka bränsletyper som används och i vilken utsträckning som el produceras i fjärrvärmesystemet så varierar resultaten. Den största minskningen av växthusgaser uppstår när ett renoveringspaket utförs på en byggnad i ett fjärrvärmesystem med hög andel biobränsle och ingen elproduktion.
7

Analys av fjärrvärme med värmeåtervinning via ventilationssystem : Effekterna i form av primärenergi och livscykelutsläpp av koldioxidekvivalenter / Analysis of district heating with ventilation heat recovery : The effects in the form of primary energy and life cycle emissions of carbon dioxide equivalents

Lipczynski, Marcus, Becke, Rasmus January 2020 (has links)
För att uppnå Sveriges energi- och klimatmål för energieffektivisering och koldioxidutsläpp måste nya tekniker och innovationer undersökas för att bidra till att göra energianvändningen mer effektiv i bostadssektorn. Ett alternativ för att uppnå målen är att använda ett integrerat värmesystem. De integrerade värmesystemen som undersöks i den här rapporten innefattar värmeåtervinning via ventilation som komplement till fjärrvärme, vilket jämförs med uppvärmning av bara fjärrvärme.   De valda integrerade värmesystemen från HögforsGST kommer undersökas ur ett livscykelutsläpps- och primärenergiperspektiv. Analysen ska utreda om systemen bidrar till att sänka energianvändningen och hur stora livscykelutsläppen av koldioxidekvivalenter är för värmesystemen i två olika fastigheter.   Slutsatsen för rapporten var att de valda integrerade värmesystemen var mer energieffektiva, då de använde mindre primärenergi, oavsett fall för elproduktion. De använde även 36 procent och 32,8 procent mindre producerad energi, för Lärlingen respektive Rundeln. Fjärrvärmesystemet medförde istället lägre totala livscykelutsläpp av koldioxidekvivalenter än det integrerade värmesystemen, för de flesta fallen av elproduktion. För att få ett mer tillförlitligt resultat bör de integrerade värmesystemen granskas under en längre tidsperiod för att vidare analysera använd primärenergi och livscykelutsläpp.
8

Energirenovering av flerbostadshus från miljonprogrammet genom LCC-optimering : En fallstudie av två byggnader i Linköping, Sverige / Energy Renovation of Multi-family Buildings from the Million Programme Using LCC-Optimisation : A Case Study of two Buildings in Linkoping, Sweden

Kindesjö, Viktoria, Nordqvist, Linda January 2019 (has links)
The content of greenhouse gases in the atmosphere is increasing resulting in climate change and efforts to stop the negative trend need to be intensified. The energy use in the Swedish residential and service sector constitutes 40 % of the total energy use of 378 TWh in the country. Nationally there is a target to reduce the energy use per heated area with 20 % to 2020 and 50 % to 2050. Energy renovation of buildings from the Million Programme is foreseen to be able to contribute to achieving the targets owing to the large building stock and energy efficiency potential. In the master thesis cost optimal energy renovation strategies are investigated for two multi-family buildings in Linkoping built during the Million Programme, one with an unheated attic and one with a heated attic. The thesis is carried out by using life-cycle cost optimisation (LCC-optimisation) by utilising the software OPERA-MILP, developed at Linkoping University. The aim of the thesis is to obtain the energy renovation strategy that is optimal from an LCC-perspective and to investigate the energy reduction and LCC. Optimal energy renovation strategies are also investigated for energy renovation to levels of the Energy Classes of the National Board of Housing, Building and Planning in Sweden and the stricter limits for nearly zero-energy buildings (NZEB) that will likely come into force in 2021. Greenhouse gas emissions and primary energy use are also investigated for the different cases with the purpose of putting energy renovation in relation to climate impact. Local environmental factors are used for district heating while electricity is assigned values based on the Nordic electricity mix and Nordic marginal electricity respectively. The current LCC and annual energy use is 2 945 kSEK and 133 MWh for the building with an unheated attic and 3 511 kSEK and 162 MWh for the building with a heated attic. The result shows that LCC can be reduced by approximately 70 kSEK and 90 kSEK respectively. The optimal solution constitutes of a window change from windows with U=3,0 W/m2°C to windows with U=1,5 W/m2°C and results in a reduction of the energy use by 13 % and 15 % respectively. LCC increases with 240 kSEK for the building with unheated attic and decreases with 18 kSEK for the other building when Energy Class D is reached. Energy Class C is attained through an increase in LCC by 300 – 590 kSEK and Energy Class B through an increase by 1610 – 1800 kSEK. It is not possible to reach Energy Class A or the future requirements for NZEB (55 kWh/m2Aheated) with the energy renovation measures that are implemented in OPERA-MILP. The largest energy reduction that can be attained is approximately 60 %. The most cost optimal insulation measure is additional insulation of the attic floor/pitched roof followed by additional insulation of the ground concrete slab. It was shown to be more cost efficient to change to windows with U=1,5 W/m2°C in combination with additional insulation compared to changing to windows with better energy performance. For greater energy savings additional insulation on the inside of the external wall is applied, while insulation on the outside of the external wall is never cost optimal. To reach Energy Class B installation of HRV is required which gives a large increase in cost. Less extensive energy renovation is needed to reach the energy classes for the building with heated attic compared to the building with unheated attic. The annual use of primary energy in the reference case is 22 MWh for the building with an unheated attic and 26 MWh for the building with a heated attic. The emissions of greenhouse gases are 18 tonnes CO2e and 22 tonnes CO2e per year respectively when the emission factor of the Nordic electricity mix is applied and 20 tonnes CO2e and 25 tonnes CO2e respectively when the Nordic marginal electricity is applied. The yearly primary energy use can be reduced with up to 7 MWh through energy renovation. When the energy renovation leads to an increase in electricity use the primary energy can however increase with up to 12 MWh. The yearly greenhouse gas emissions can be decreased with up to 14 tonnes CO2e. When Nordic marginal electricity is applied to estimate the emissions of greenhouse gases for an energy renovation strategy that leads to an increase in electricity use the result is less beneficial from a climate perspective compared to when Nordic electricity mix is applied.
9

Fjärrvärme och frånluftsvärmepump : Systemets lönsamhet och primärenergitalets inverkan

Wennberg, Tim January 2019 (has links)
Kombinationen av fjärrvärme och frånluftsvärmepump (FVP) har blivit allt vanligare i Sverige. Detta kombinerade värmesystem är väl lämpat för att reducera energianvändningen i befintliga fastigheter med mekanisk frånluftventilation som saknar värmeåtervinning. Dock kan en FVP-installation leda till högre returtemperaturer i fjärrvärmenätet vilket det ofta finns avgifter för i dagsläget. För att främja fjärrvärmeanvändning sommartid använder fjärrvärmeleverantören sig av säsongsvarierande prismodeller i vilket fjärrvärmepriset varierar under en del av året. Genom att stänga av FVP sommartid och endast bruka fjärrvärme finns en potentiell kostnadsbesparing då fjärrvärmepriset är som lägst. Denna kostnadsbesparing undersöks utifrån olika typer av fjärrvärmetaxor, elnätsavgifter och elhandelspris. Det undersöks också hur Boverkets regler för beräkning av primärenergital påverkar denna värmesystemtyp. Typiska prismodeller för fjärrvärme har undersökts, samt så har energianvändning framräknats för sex fiktiva flerbostadshus runtom i landet. För varje byggnad beräknas energianvändningen utifrån tre fall. I referensfallet, Fall 1 används bara fjärrvärme och i Fall 2 används FVP till både uppvärmning och tappvarmvatten (TVV). Fall 3 är som Fall 2 fast FVP täcker inget TVV-behov och stängs av under sommar-perioden. Energianvändningen är framräknad över ett år och energikostnaden jämförs mellan fallen. I Fall 2 och Fall 3 är de totala energikostnaderna för byggnaderna mellan 61–75% respektive 67–78% av energikostnaderna i Fall 1. Mellan Fall 2- och 3 finns däremot ingen tydlig besparingstrend trots att alla fjärrvärmenät på orterna har ett säsongsvarierande fjärrvärmepris. Att ingen besparingstrend uppstår påvisar att kostnaden för varje levererad värmeenhet från FVP sommartid är ungefär lika stor som varje värmeenhet fjärrvärme. Detta beror på att en hög värmefaktor används vilket gör det väldigt kostnadseffektivt att köpa el. Med en lägre värmefaktor gynnas avstängning av FVP sommartid. Utifrån den framräknade energianvändningen beräknas primärenergitalet och den specifika energianvändningen för samtliga byggnader. Primärenergitalet är i de flesta fall större än den specifika energianvändningen för att elanvändningen räknas upp. I Luleå är däremot den specifika energianvändningen större än primärenergitalet, även vid användning av FVP. / The combination of district heating and exhaust air heat pump (EAHP) has become increasingly common in Sweden. This combined heating system is well suited for reducing energy use in existing buildings with mechanical exhaust air ventilation that lacks heat recovery. However, an EAHP installation can lead to higher return temperatures in the district heating network. In order to promote district heating use during the summer, the district heating supplier use seasonal varying price models in which the district heating price varies during some of the year. By shutting down EAHP in summer and only using district heating, there is a potential cost saving as the district heating price is at its lowest. This cost saving is investigated based on various types of district heating tariffs, electricity grid charges and electricity prices. It is also examined how Boverket's rules for calculating primary energy affects this type of heating system. Typical price models for district heating have been investigated. The energy use for six fictitious multi-dwelling buildings around the country has also been made. For each building, the energy use was calculated from three cases. For the reference case, Case 1, only district heating is used, for Case 2 EAHP is used for both heating and domestic hot water and Case 3 is as Case 2 fixed EAHP does not cover domestic hot water requirements and is switched off during the summer period. The energy consumption is calculated over a year and the energy cost is compared between the cases. In Case 2 and Case 3, the total energy costs for the buildings are between 61–75% and 67–78% of the energy costs in Case 1, respectively. However, between Case 2- and 3, there is no clear saving trend despite all the locations having a seasonally varying district heating price. The fact that no saving trend arises shows that the cost of each heat unit delivered from FVP in the summer is about the same as each heating unit of district heating. This is because a high COP (coefficient of performance) is used, which makes it very cost-effective to buy electricity. With a lower COP, shutdown of EAHP benefits summer time. Based on the calculated energy use, the primary energy and the specific energy use are calculated for all buildings. In most cases, the primary energy number is larger than the specific energy use, as the electricity consumption is going to be larger with primary energy. In Luleå, on the other hand, the energy-area ratio is greater than the primary energy number, even when using an EAHP.

Page generated in 0.0573 seconds