Spelling suggestions: "subject:"prostheses"" "subject:"prosetheses""
261 |
Avaliação da percepção auditiva da fala em pacientes submetidos ao reimplante coclear / Evaluation of auditory speech perception in patients submitted to cochlear reimplantationCosta, Lucas Bevilacqua Alves da 18 July 2018 (has links)
Estudo retrospectivo, descritivo e longitudinal realizado na Seção de Implante Coclear, Centro de Pesquisas Audiológicas do Hospital de Reabilitação de Anomalias Craniofaciais da Universidade de São Paulo (IC-CPA/HRAC/USP). O objetivo deste estudo foi caracterizar o desempenho da percepção auditiva da fala de indivíduos submetidos à cirurgia de reimplante coclear. No total de 1.323 indivíduos submetidos à cirurgia de implante coclear no período de 1990 a janeiro de 2016, consta o registro de 84 indivíduos submetidos à cirurgia de reimplante coclear, correspondendo a 6,3% do total. Deste total de 84, 68 indivíduos atenderam aos critérios de inclusão/exclusão da pesquisa e foram avaliados utilizando-se testes de percepção auditiva da fala, em três momentos: antes da segunda intervenção cirúrgica, após o reimplante e última avaliação de acompanhamento. As variáveis estudadas foram: a) motivo do reimplante coclear; b) etiologia da perda auditiva; c) idade na primeira cirurgia; d) tempo de uso do implante coclear antes do reimplante; e) tempo de recuperação do escore anterior à intervenção; f) tempo de uso atual; g) escore nos procedimentos de avaliação da percepção auditiva da fala, pré e pós-reimplante coclear. Na análise dos dados foi possível observar que a causa mais comum do reimplante foi a falha do dispositivo interno, seguido de razões médicas. Na avaliação auditiva da fala, um total de 61 (89,7%) recuperaram o desempenho observado antes do reimplante coclear e sete (10,3%), não alcançaram o mesmo desempenho. Constatou-se que as variáveis idade do primeiro Implante e tempo de uso do primeiro Implante Coclear, assim como tempo de reimplante, influenciaram nos resultados encontrados. A cirurgia de reimplante coclear é um procedimento viável, contudo a família e o paciente devem ser orientados quanto aos possíveis comprometimentos na percepção auditiva da fala / A retrospective, descriptive and longitudinal study performed in the Cochlear Implant Section, Audiological Research Center of the Hospital of Rehabilitation of Craniofacial Anomalies of the University of São Paulo (IC-CPA / HRAC / USP). This study aimed at characterizing the auditory speech perception of individuals undergoing cochlear reimplantation surgery. Out of 1,323 individuals undergoing cochlear implant surgery from 1990 to January 2016, 84 (6.3%) subjects underwent cochlear reimplantation surgery. From this total of 84, 68 individuals met the inclusion / exclusion criteria of the study and were evaluated using auditory speech perception tests in three moments: before the second surgical intervention, after reimplantation and the last follow-up evaluation. The variables studied were: a) reason for cochlear reimplantation; b) etiology of hearing loss; c) age at first surgery; d) time cochlear implant use before reimplantation; e) recovery time from the previous intervention score; f) time of current use; g) score in the procedures of assessment of auditory speech perception before and after cochlear reimplantation. The data analysis showed that the most common cause of reimplantation was the failure of the internal device, followed by medical reasons. In the auditory speech evaluation, a total of 61 (89.7%) recovered performance before cochlear reimplantation, and seven (10.3%), did not reach the same performance. It was verified that the variables age at the first Implant and time using the first Cochlear Implant, as well as time of reimplantation, influenced the results. Cochlear replantation surgery is a viable procedure, however, the family and the patient should be advised on the possible compromising risks to the auditory speech perception
|
262 |
Correção de defeitos ventrais em ratos com próteses de polipropileno e politetrafluoroetileno expandido: análises histológica, biomecânica e da resposta aderencial / Repair of abdominal wall defects in rats with polypropylene and expanded polytetrafluoroethylene prostheses: histological, biomechanical and adhesion formation analysisAmico, Enio Campos 30 March 2005 (has links)
Atualmente os defeitos herniários da parede abdominal são freqüentemente corrigidos com o uso de biomateriais. Embora utilizada com bons resultados há várias décadas, a prótese de Polipropileno (PP) tem implicado graves complicações decorrentes de aderências aos órgãos abdominais. A prótese de Politetrafluoroetileno expandido (PTFEe) tem reconhecidamente menor potencial aderencial; no entanto, dados obtidos de estudos biomecânicos deixam dúvida quanto a sua real eficiência na correção herniária. O objetivo do estudo foi comparar esses dois diferentes tipos de próteses na correção de defeitos ventrais produzidos em ratos Wistar, levando-se em consideração parâmetros histológicos, biomecânicos e da resposta aderencial. Para o estudo histológico um grupo de animais (n=21) foi submetido simultaneamente a implante subperitoneal de fragmentos de próteses de PP e PTFEe. Para o estudo comparativo da resposta biomecânica e aderencial entre as próteses, procedeu-se ao implante protético subperitoneal com PP (n=21) e PTFEe (n=21) para corrigir defeitos ventrais criados cirurgicamente envolvendo toda a espessura da parede abdominal dos animais. Para análise biomecânica, dois outros grupos de animais foram utilizados como controle: um grupo não submetido à cirurgia (n=15) e um grupo com correção de defeitos ventrais por meio de sutura (n=21). Todas as avaliações foram realizadas com 1, 2 e 4 semanas de pós-operatório e constituíram-se de: avaliação da resposta aderencial por meio de pesquisa da área de prótese aderida e incidência de aderência a órgãos, avaliação biomecânica por meio de ensaios de tração de tiras de parede abdominal e avaliação morfométrica do tecido inflamatório e das fibras colagênicas em cortes histológicos corados por Hematoxilina-eosina e pelo método da Picrossírius-polarização, respectivamente. Os resultados mostraram que: a fração de volume de tecido inflamatório no grupo PP na primeira, segunda e quarta semanas foi respectivamente: 20%, 9% e 4% enquanto no grupo PTFEe: 30%, 16% e 16%. Houve diferença estatística na segunda e quarta semanas. A fração de volume de colágeno fibrilar no grupo PP foi respectivamente: 65%, 71% e 77%, na primeira, segunda e quarta semanas. No grupo PTFEe os valores foram: 55%, 66% e 68%, na primeira, segunda e quarta semanas. Da mesma forma, houve diferença estatística na segunda e quarta semanas. Na análise semiquantitativa do grau de agregação de colágeno foi observado diferença estatística apenas primeira semana de pós-operatório a favor do PP (3,24 x 1,40 p=0,022). As próteses induziram valores semelhantes de área aderida na primeira (67,85%-PP x 71,42%- PTFEe), segunda (60,71%-PP x 60,71%-PTFEe) e quarta semanas de pós-operatório (46,42% PP x 42,85% PTFEe). Quanto à presença de aderência a órgãos abdominais houve diferença entre as próteses apenas na primeira semana a favor do PTFEe: enquanto 85,7% dos animais no grupo PP apresentaram aderências à órgãos, esse índice foi de apenas 28,5% no grupo PTFEe. Os valores de força máxima obtidos nos ensaios biomecânicos de tração com a prótese de PP foram na primeira, segunda e quarta semanas: 20,54 N, 21,62 N e 26,23 N. No grupo PTFEe os valores na primeira, segunda e quarta semanas foram: 16,92 N, 23,12 N e 25,41 N. Foi observada diferença estatística na primeira semana de pós-operatório. A comparação entre os implantes protéticos de PP e PTFEe nas condições da presente pesquisa permitiu concluir: 1) A estimativa de área aderida à prótese foi semelhante independentemente do material implantado; 2) Com 1 semana de pós-operatório, o implante de PP demonstrou-se mais resistente aos ensaios biomecânicos de tração o que se correlacionou a um maior grau de agregação das fibras colagênicas nos tecidos implantados; 3) Com 1 semana de pós-operatório, os implantes de PTFEe induziram aderências as órgãos abdominais em um menor número de animais; 4) Com 2 e 4 semanas de pós-operatório o implante de PP induziu a uma menor infiltração de tecido inflamatório e a um maior depósito de colágeno fibrilar / Nowadays, abdominal wall defects are frequently repaired with biomaterials. Although utilized with good results for several decades, polypropylene mesh (PP) has been implicated with serious complications due to adhesion to the abdominal organs. It has been reported that prostheses of expanded polytetrafluoroethylene (ePTFE) mesh exhibit less adhesion formation potential; however, data obtained by biomechanical studies leave doubt as to its real efficiency in hernia repair. The objective of the present study was to compare these two types of mesh in the correction of ventral defects created in Wistar rats, taking into account histological and biomechanical parameters and the adhesion response. For the histological study, a group of animals (n = 21) was submitted simultaneously to subperitoneal implantation of fragments of PP and ePTFE mesh. For the comparative study of the biomechanical and adhesion response between the prostheses, subperitoneal implantation with PP (n = 21) and ePTFE mesh (n = 21) was performed to repair surgically created abdominal defects, involving all layers of the abdominal wall. In the biomechanical analysis, two other groups of animals were used for the control: a group not submitted to surgery (n = 15) and a group with abdominal wall defects repaired with sutures (n = 21). At postoperative weeks 1, 2 and 4, the following evaluations were performed: study of the adhesion response by measuring the incidence of adherence to organs and area of adhered prosthesis; biomechanical test of abdominal wall strips; and morphometric study of the inflammatory tissue and collagenic fibers in sections stained with hematoxylin-eosin and by Picrosiriuspolarization technique. The results showed that: the inflammatory tissue volume in group PP at postoperative weeks 1, 2 and 4, respectively, was 20%, 9% and 4%; while in the group ePTFE the values were 30%, 16% and 16%. The difference was statistically significant in postoperative weeks 1 and 4. The collagen fibril volume in group PP was: 65%, 71% and 77%, in postoperative weeks 1, 2 and 4, respectively. In group ePTFE the values were: 55%, 66% and 68%. Likewise, there was a statistically significant difference in postoperative weeks 2 and 4. In the semi-quantitative analysis of the degree of collagen aggregation, a statistically significant difference was only observed in postoperative week 1, in favor of PP (3.24 x 1.40, p = 0.022). The prostheses induced similar values for adhered area in postoperative week 1 (67.85%-PP vs. 71.42%-ePTFE), week 2 (60.71%-PP vs. 60.71%-ePTFE) and week four (46.42% PP vs. 42.85% ePTFE). Regarding the presence of adherence to abdominal organs, there was only a statistically significant difference between the prostheses in week one, in favor of ePTFE. While 85.7% of the animals in group PP presented adherence to organs, this index was only 28.5% in group ePTFE. The maximum force obtained in the biomechanical tests with the PP mesh was 20.54 N, 21.62 N and 26.23 N, in postoperative weeks 1, 2 and 4, respectively. In group ePTFE the values were 16.92 N, 23.12 N and 25.41 N. A statistically significant difference was observed in postoperative week 1. The comparison between PP and ePTFE prosthetic implants in the conditions of the present research enabled the conclusion that: 1) the estimated area adhered to the prostheses was similar, irrespective of the implanted material; 2) at postoperative week 1, the resistance to traction was higher when the repair was done with PP mesh, which was correlated to a higher degree of collagen fiber aggregation in the implanted tissues; 3) at postoperative week 1, fewer visceral adhesions were formed on ePTFE group of animals; and 4) at postoperative weeks 2 and 4, the PP implant induced a smaller infiltration of inflammatory tissue and a larger deposit of collagen fibrils
|
263 |
Avaliação da resistência à fratura de prótese parcial fixa provisória confeccionada sobre componentes do tipo UCLA em titânio - efeito de diversos reforços / Fracture resistance evaluation of provisional fixed partial denture made on titanium ucla components several reinforcements effectAlmonte, Thania Grisel Rodriguez 31 May 2005 (has links)
As restaurações provisórias no tratamento reabilitador oral são de suma importância. Por isso é preocupante que os materiais utilizados para a execução das mesmas sejam críticos com relação à sua resistência e longevidade, principalmente, quando estas são executadas em tratamentos prolongados e/ou em espaços desdentados extensos. O objetivo deste trabalho foi avaliar em 4 grupos reforçados, compostos por 9 espécimes cada um, a resistência e o modo de fratura, de uma resina acrílica poli(metilmetacrilato) auto-polimerizável (Dencor® - Clássico®, São Paulo, SP, Brasil) utilizada para restaurações provisórias quando reforçada com fibras de vidro (Fibrante® e Interlig® - Angelus®, Londrina, PR, Brasil), fibras de aramida (Kevlar® - Du Pont®, USA) y fio ortodôntico ∅ 0, 7mm. E um grupo controle sem nenhum tipo de reforço, com a mesma quantidade de corpos de prova. A análise dos resultados (ANOVA, p < 0,05), para o teste de resistência, mostrou haver diferença estatística entre os grupos. O teste de Tukey encontrou que os grupos reforçados, aqueles que alcançaram maior média de resistência à fratura foram os que utilizaram a fibra de vidro trançada pré-impregnada com resina composta foto-polimerizável, Interlig® (1083 N); a fibra de vidro unidirecional préimpregnada com dimetacrilato de glicol, Fibrante® (1022 N) e a fibra de poli(aramida) unidirecional sem pré-impregnação, Kevlar® 29, aumentando em 26%, 22% e 17%, respectivamente, esta resistência em relação ao grupo controle (800 N), não havendo diferença estatística significante entre eles. O grupo reforçado com fio de aço com ∅ 0,7 mm (871 N) apareceu em seguida com uma resistência somente 8% maior e semelhante àquela apresentada pelo grupo controle sem reforço. A análise das fraturas concorreu com a elaboração de um novo sistema de classificação dividindo-as em quatro tipos: Ausente, Parcial, Total Não Separada e Total Separada. As fraturas dos espécimes reforçados foram consideradas mais favoráveis ocorrendo, predominantemente, os tipos Ausente e Parcial. / Provisional restorations are of ultimate importance in the oral rehabilitation treatment. Thus, clinicians have to bear in mind that materials used for their fabrication are critical due to its longevity and strength, when these are done for longterm therapy and/or large edentulous spaces. The aim of this work was to evaluate the flexural resistance and fracture mode of an auto-cure polymethylmetacrilate resin (Dencor® - Classico® , Sao Paulo, SP, Brasil) used for provisional restorations and reinforced with four materials. Samples were divided in four groups of nine each, as the following: glass fiber (Fibrante® and Interlig® Angelus®, Londrina, PR, Brasil), aramide fibers (Kevlar® Du Pont®, USA), and orthodontic wire ∅ 0,7mm. one group whitout reinforcement served as control. Data was submitted to statistical analysis with one-way ANOVA (p<.05) test. Results showed statistically significant difference among the groups. Tukeys test showed that glass-fiber Interlig® exhibited the greatest value of flexural strength (1083 N); followed by unidirectional glycol dimetacrylate glass-fiber Fibrante® (1022 N) and aramid fiber Kevlar® (966 N). These values represent 26%, 22% and 17% in relation to the control group (800 N), being non statistically significant difference observed among them. The group with ∅ 0,7mm orthodontic wire (871 N) had a resistance only 8% higher and similar of that of control group without reinforcement. Fracture analysis was conducted by the following scale: absence, partial, complete without separation, and complete with separation. Fracture modes observed on reinforced samples were considered more favorable, with types absent and partial seeing more frequently.
|
264 |
Eficácia do uso do Templating na artroplastia total do quadril.Devito, Fábio Stucchi 17 April 2009 (has links)
Made available in DSpace on 2016-01-26T12:51:22Z (GMT). No. of bitstreams: 1
fabiostuchidevito_tese.pdf: 1050230 bytes, checksum: 52d8e95acef4a4ba2f5e60d301266786 (MD5)
Previous issue date: 2009-04-17 / Total hip arthroplasty is a surgery with a high success rate, providing pain relief and improvement of the articular mobility. Long-term success is related to the position and orientation of the acetabular and femoral components. Traditional preoperative planning entails radiographic analysis of the pelvis, in which a template is placed on the image, allowing an analysis of the appropriate size of the Exeter cemented prosthesis. Objective: To evaluate the effectiveness of traditional preoperative planning with the use of templating. Patients and Method: Forty-three anteroposterior X-rays were analyzed by three experienced surgeons. The evaluation of each surgeon was compared with the actual prosthesis used in the surgery and also compared with the assessment of the other two surgeons. Cohen's Kappa concordance test and weighted Kappa indexes using quadratic weighting were used for statistical analysis with a confidence interval of 95%. Results: The preoperative evaluations of Surgeons A, B and C were divided into the analysis of the sizes of the acetabular cup, stem and plug of the distal femoral canal. Surgeon A obtained a moderate agreement in relation to the acetabular component and substantial agreements in relation to the stem and plug. Surgeon B had moderate agreement in relation to both the acetabulum and the stem and substantial agreement in relation to the plug. Surgeon C obtained moderate agreement in relation to the analysis of the acetabulum and the plug and substantial agreement for the stem. The intra-observer agreement test demonstrated a prevalence of slight agreement in relation to the acetabulum and substantial agreement in relation to the stem and to the plug. Conclusion: Templating used in preoperative planning proved effective; however, there was a prevalence of slight and moderate agreement in relation to the size of the acetabular component according to the inter- and intra-observer analysis. / A artroplastia total do quadril é uma cirurgia com alto índice de sucesso, atuando no alívio da dor e melhora da mobilidade articular e seu êxito a longo prazo relaciona-se à posição e orientação do componente acetabular e femoral. O planejamento pré-operatório tradicional consiste na análise radiográfica da bacia, na qual será sobreposto um templating , o que permite a análise do tamanho adequado da prótese Exeter cimentada. Objetivo: Avaliar a eficácia do planejamento pré-operatório tradicional pelo uso do templating . Casuística e Método: Quarenta e três radiografias na posição antero-posterior e foram analisadas por três cirurgiões experientes; as avaliações de cada cirurgião foram comparadas com a prótese utilizada na cirurgia e cada resultado comparado com os resultados dos outros dois. Para avaliação, utilizou-se o teste de concordância do Capa de Cohen e do Capa ponderado, com ponderação quadrática e intervalo de confiança de 95%.Resultados: Os resultados pré-operatório encontrados pelo examinadores A, B e C foram divididos como análise do tamanho do acetábulo, haste e plug do canal femoral distal. O cirurgião A obteve em relação ao componente acetabular uma concordância moderada, e em relação à haste e ao plug uma concordância substancial. O cirurgião B apresentou resultado de concordância moderada em relação ao acetábulo e à haste e substancial em relação ao plug. O cirurgião C na análise acetabular e do plug obteve concordância moderada e substancial quanto à haste. O teste de concordância intra-observador apresentou uma prevalência da concordância leve em relação ao acetábulo e substancial em relação à haste e ao plug. Conclusão: O templating utilizado no planejamento pré-operatório mostrou-se eficaz, no entanto, em relação ao tamanho do componente acetabular houve um predomínio de concordância leve e moderada na análise inter e intraobservador.
|
265 |
Avaliação de endoprótese nacional em traquéia de coelhos. / Auto-expansible endoprosthesis. Biocompatibility in rabbits trachea.Faria, Celso Murilo Nálio Matias de 22 November 2011 (has links)
Made available in DSpace on 2016-01-26T12:51:38Z (GMT). No. of bitstreams: 1
celsomurilonmdefaria_dissert.pdf: 1426679 bytes, checksum: 62fc4b90d691c716aef67c9e6590368e (MD5)
Previous issue date: 2011-11-22 / Introduction: the utilization of endoprosthesis has its main indication in the neoplasic obstructions do not surgically treatable. The foreign industry dependence is one of the barriers we found for the broad utilization of such devices. The relevance of this research is the development of a national prosthesis from easy access and low cost. Objective: to assess the biocompatibility of nitinol endoprosthesis with polyurethane in the rabbits trachea. Material and Method: Seventeen rabbits were studied from the New Zealand breed (Oryctolagus Sylvilagus), eight male and five female, with an average weight of 3255g (from 2570 to 4270g). The endoprosthesis were applied orally through laringoscopy, under general anesthesia and released in the middle third of the trachea. Radiological study was made to assure the placement of the endoprosthesis that allowed to compare the index of migration of the endoprosthesis in millimeters. The proposed time segment was 30 days. The microscopic variables study was proceeded: dilatation, incorporation and granolomatous tissue and histological cuts from the tracheal and lungs segments for microscopic study. The histological study measured the inflammatory process, the parietal alterations and the kind of epithelium observed in the tracheal bed. Results: Thirteen animals were included in the final study. The average segment time was 26 days (15 to 35 days in observation). Six animals underwent a radiological study during euthanasia and it was demonstrated displacement with migration of the prosthesis for the distal trachea in five animals. There was absence in one. It was shown the prosthesis had a complete expansion in seven animals and partial expansion in six. The incorporation of prosthesis in the tracheal lumen was observed in two animals and adhered in eleven. Granulomatous tissue was present in ten animals and absent in three. The histological study of the mucosa and submucosa showed inflammatory process predominantly of Polymorphonuclear cells as in the contact region with the prosthesis as in the proximal. The depth of the inflammatory process in the tracheal wall was larger in the tracheal area in contact with the prosthesis. The alterations of the respiratory epithelium: the metaplasia parameter was the most frequent in the area without contact with the prosthesis. Corrosion and ulceration were predominant in the area in contact with the prosthesis. The metaplasia parameter was the most frequent in the area in contact with the prosthesis. Conclusion: the nitinol endoprosthesis auto-expandable covered with polyurethane, produced by Braile Biomédica and implanted in the trachea of rabbits was easy to apply and liberation in the tracheal lumen. The endoprosthesis recovered with polyurethane showed in radiographic assessment distal migration, good radial expandability and formation of granuloma tissue. It was also observed an inflammatory process predominantly acute and restricted to the superficial portions of the trachea. The most frequent epithelium alterations in contact with the prosthesis were ulceration and regenerative hyperplasia. / Introdução: a utilização de endoprótese tem a principal indicação nas obstruções neoplásicas e nas obstruções não tratáveis cirurgicamente. A dependência da indústria estrangeira é uma das barreiras para utilização ampla destes dispositivos. A relevância deste trabalho é o desenvolvimento de uma prótese nacional de fácil acesso e baixo custo. Objetivo: avaliar endoprótese de nitinol revestida com poliuretano, na traqueia de coelhos. Material e Método: foram estudados 17 coelhos, da raça Nova Zelândia (Oryctolagus Cuniculus). Oito machos e nove fêmeas, com peso médio de 3522g (de 2570 a 4270g). As endopróteses foram aplicadas via oral, por meio de laringoscopia, sob anestesia geral, e liberadas no terço médio das traqueias. Realizou-se estudo radiológico para assegurar a posição da endoprótese que permitiu comparar o índice de migração da endoprótese em milímetros. O tempo proposto de seguimento foi de 30 dias. Procedeu-se ao estudo das variáveis macroscópicas: dilatação, incorporação e tecido de granulação e cortes histológicos dos segmentos traqueais e pulmonares para estudo microscópico. O estudo histológico mensurou o processo inflamatório, as alterações parietais e o tipo de epitélio observado no leito traqueal. Resultados: 13 animais foram incluídos no estudo definitivo. O tempo médio de seguimento foi 26 (15 a 35) dias em observação. Em seis animais submetidos a estudo radiológico por ocasião da eutanásia, demonstrou-se deslocamento com migração da prótese para traqueia distal, em cinco; ausência de migração em um. Demonstrou-se que a prótese tinha expansão completa em sete animais e parcial em seis. A incorporação da prótese na luz traqueal foi observada em dois animais, e aderido em 11. Tecido de granulação esteve presente em dez animais e ausente em três. O estudo histológico da mucosa e submucosa demonstrou processo inflamatório com predomínio de polimorfonucleares tanto na região em contato com a prótese quanto na proximal. A profundidade do processo inflamatório na parede traqueal foi maior na área traqueal em contato com a prótese. Das alterações do eptélio respiratório, o parâmetro metaplasia foi o mais frequente na área sem contato com a prótese. Corrosão e ulceração predominaram na área em contato com a prótese. Conclusões: A escolha do coelho no desenho do presente estudo prejudicou o resultado. Trata-se de estudo pioneiro tanto na utilização de coelho para estudo de endoprótese, quanto no desenvolvimento de endoprótese metálica autoexpansível nacional. As dificuldades foram naturais deste pioneirismo, mas prejudicaram o resultado final. A endoprótese autoexpansível de nitinol recoberta de poliuretano, produzida pela Braile Biomédica Ltda, (Brasil) e implantada na traqueia de coelhos, demonstrou-se de fácil aplicação e liberação na luz traqueal. Apresentou elevada taxa de migração, boa expansibilidade radial. Verificou-se alta frequência na formação de tecido de granulação e baixa permeabilidade. Observou-se ainda processo inflamatório predominantemente agudo e restrito ás porções superficiais da traquéia. As alterações epiteliais mais freqüentes em contato com a prótese foram ulceração e hiperplasia regenerativa.
|
266 |
Projeto e construção de um motor elétrico linear aplicado à bioengenharia / Design and construction of a linear electric motor applied to bioengineeringJuliani, Aline Durrer Patelli 14 January 2011 (has links)
Considerando-se o atual estagio de desenvolvimento das máquinas elétricas, tanto em termos de ferramentas computacionais auxiliares nas simulações e nos projetos, quanto de materiais e sistemas eletrônicos de acionamento e controle, propõe neste trabalho a construção de um dispositivo eletromecânico, na classe dos motores elétricos lineares, que atenda as necessidades e se aplique a bioengenharia, mais propriamente as próteses de membro superior, na forma de acionador translacional. Este dispositivo deve substituir os sistemas que utilizam motores elétricos rotativos com mecanismos de adaptação mecânica (roldanas, vários fios, redutores), que convertem o movimento rotacional em linear. Também, os dispositivos híbridos, como atuadores eletro-hidráulicos e eletropneumáticos, que necessitam de fontes de energia de naturezas diferentes da eletroeletrônica, podem ser substituídos pelas maquinas elétricas lineares. Uma revisão dos conceitos relacionados a área de bioengenharia e feita, destacando-se os mecanismos de transmissão existentes. E apresentada uma analise comparativa entre os principais motores lineares, enfatizando-se as características construtivas, as vantagens e as desvantagens de cada um, relacionados a aplicação. A escolha da maquina a ser projetada e construída recaiu no motor linear síncrono, com imas permanentes na superfície da parte móvel, em uma estrutura tubular. Para esta maquina, e exposta uma metodologia de projeto, baseando-se nos seguintes tópicos: equacionamento do circuito magnético, cálculos de parâmetros utilizando-se o método dos elementos finitos e modelagem matemática por meio das equações por fase. Apos a etapa teórica, a construção da maquina e apresentada juntamente com os ensaios experimentais, possibilitando a comparação das características reais em relação ao projeto inicial. Por fim, o motor e aplicado ao dedo artificial, verificando-se a sua capacidade de substituição do motor rotativo. / By means of the latest technological advances of the electrical machines, both in terms of computational aids in simulations and designs, materials and electronic systems of drive and control, this work put forward the construction of an electromechanical device, in the class of the linear motors. It will be applied to bioengineering area, in particular in upper limb prostheses, in the form of a translational actuator. This linear motor must substitute the systems that use electric rotational motors with planetary gears and lead screw transmission, to convert the rotational movement into linear. The hybrid mechanisms, like electro pneumatic/hydraulic actuators, which need energy sources different from electronics, can be changed for the linear electric machines too. A review about bioengineering topics is done, where the existent mechanical mechanisms are highlighted. According to the application necessities, the advantages and disadvantages of different topologies of electric linear machines are compared and the constructive characteristics are emphasized. The tubular linear synchronous motor, with permanent magnets on the surface of the mobile part, was chosen to be applied to hand prostheses. To this machine, a design methodology is presented for calculating the motor dimensions, based on the following subjects: magnetic circuit equating, finite element analyses to evaluate parameters and machine dynamic modeling. After the theorethical stage, the construction of the machine is presented with the experimental results, allowing comparisons between the real characteristics and the initial design features of the motor. Finally, the machine is applied to an artificial finger to verify its capability to replace the rotational motor.
|
267 |
A média complexidade no quadro da Política Nacional de Saúde Bucal: uma abordagem do seu processo de desenvolvimento em uma perspectiva regional / The medium complexity in the National Oral Health Policy: an approach to the development process under a regional perspectiveRenata Ferraiolo Peixoto Fortuna 26 April 2011 (has links)
Esta tese tem por objeto o processo de regionalização das ações de média complexidade e da oferta de próteses dentárias no âmbito da Política Nacional de Saúde Bucal (PNSB). Foram realizadas duas pesquisas fundamentais para o entendimento desse processo: a primeira esteve voltada para o levantamento da descrição da oferta de ações especializadas e de próteses dentárias nos Planos Diretores de Regionalização (PDR) nas 27 unidades federadas do país. A segunda pesquisa verificou a cobertura por Equipes de Saúde Bucal (ESBs) na Estratégia de Saúde da Família (ESF) e a distribuição dos 844 Centros de Especialidades Odontológicas (CEOs) e dos 526 Laboratórios Regionais de Próteses Dentárias (LRPDs) implantados até setembro de 2010 nas regiões de saúde do Brasil dos 27 estados da federação. Essas pesquisas permitiram concluir que: os PDRs, na grande maioria dos estados brasileiros, não contribuíram para a organização regionalizada da distribuição de CEOs e LRPDs no Brasil. A cobertura por Equipes de Saúde Bucal é heterogênea, com predominância da Região Nordeste e dos municípios de pequeno porte, em detrimento das capitais e dos estados das regiões Sul e Sudeste. No tocante à distribuição das unidades CEO e LRPD pelas regiões de saúde, a pesquisa mostrou que os critérios normativos para a seleção dos municípios a sediarem essas unidades vêm sendo cumpridos de forma precária na maior parte do país. Além disso, a distribuição dessas unidades não apresenta coerência com os princípios da regionalização prevista pelo Pacto de Gestão do SUS. / This thesis analyzes the process of regionalization of medium complexity actions and the supply of dental prostheses in the National Oral Health Policy (PNSB). Two main surveys were made for the understanding of this process: the first was aimed at describing the offer of specialized actions and dental prostheses according to the Regionalization Master Plans (PDR) in 27 federal units of the country. The second study examined the coverage by Oral Health Teams (ESBs) in the Family Health Strategy (ESF) and the distribution of 844 Specialized Dental Centers (CEOs) of 526 Regional Laboratories of Dental Prostheses (LRPDs) deployed by September 2010 in the Brazilian health regions in 27 states. These surveys showed that: the PDRs, in the vast majority of Brazilian states, have not contributed to the organization of regionalized distribution of CEOs and LRPDs in Brazil. Coverage by ESBs is heterogeneous, mostly in the Northeastern Region and in small towns, at the expense of the capital and the Southern and Southeastern states. Regarding the distribution of CEO and LRPD units by health regions, the survey showed that the normative criteria for the selection of municipalities to settle these units have been precariously completed in most of the country. Moreover, the distribution of those units is not consistent with the regionalization principles provided by the SUS Management Pact.
|
268 |
Projeto e construção de um motor elétrico linear aplicado à bioengenharia / Design and construction of a linear electric motor applied to bioengineeringAline Durrer Patelli Juliani 14 January 2011 (has links)
Considerando-se o atual estagio de desenvolvimento das máquinas elétricas, tanto em termos de ferramentas computacionais auxiliares nas simulações e nos projetos, quanto de materiais e sistemas eletrônicos de acionamento e controle, propõe neste trabalho a construção de um dispositivo eletromecânico, na classe dos motores elétricos lineares, que atenda as necessidades e se aplique a bioengenharia, mais propriamente as próteses de membro superior, na forma de acionador translacional. Este dispositivo deve substituir os sistemas que utilizam motores elétricos rotativos com mecanismos de adaptação mecânica (roldanas, vários fios, redutores), que convertem o movimento rotacional em linear. Também, os dispositivos híbridos, como atuadores eletro-hidráulicos e eletropneumáticos, que necessitam de fontes de energia de naturezas diferentes da eletroeletrônica, podem ser substituídos pelas maquinas elétricas lineares. Uma revisão dos conceitos relacionados a área de bioengenharia e feita, destacando-se os mecanismos de transmissão existentes. E apresentada uma analise comparativa entre os principais motores lineares, enfatizando-se as características construtivas, as vantagens e as desvantagens de cada um, relacionados a aplicação. A escolha da maquina a ser projetada e construída recaiu no motor linear síncrono, com imas permanentes na superfície da parte móvel, em uma estrutura tubular. Para esta maquina, e exposta uma metodologia de projeto, baseando-se nos seguintes tópicos: equacionamento do circuito magnético, cálculos de parâmetros utilizando-se o método dos elementos finitos e modelagem matemática por meio das equações por fase. Apos a etapa teórica, a construção da maquina e apresentada juntamente com os ensaios experimentais, possibilitando a comparação das características reais em relação ao projeto inicial. Por fim, o motor e aplicado ao dedo artificial, verificando-se a sua capacidade de substituição do motor rotativo. / By means of the latest technological advances of the electrical machines, both in terms of computational aids in simulations and designs, materials and electronic systems of drive and control, this work put forward the construction of an electromechanical device, in the class of the linear motors. It will be applied to bioengineering area, in particular in upper limb prostheses, in the form of a translational actuator. This linear motor must substitute the systems that use electric rotational motors with planetary gears and lead screw transmission, to convert the rotational movement into linear. The hybrid mechanisms, like electro pneumatic/hydraulic actuators, which need energy sources different from electronics, can be changed for the linear electric machines too. A review about bioengineering topics is done, where the existent mechanical mechanisms are highlighted. According to the application necessities, the advantages and disadvantages of different topologies of electric linear machines are compared and the constructive characteristics are emphasized. The tubular linear synchronous motor, with permanent magnets on the surface of the mobile part, was chosen to be applied to hand prostheses. To this machine, a design methodology is presented for calculating the motor dimensions, based on the following subjects: magnetic circuit equating, finite element analyses to evaluate parameters and machine dynamic modeling. After the theorethical stage, the construction of the machine is presented with the experimental results, allowing comparisons between the real characteristics and the initial design features of the motor. Finally, the machine is applied to an artificial finger to verify its capability to replace the rotational motor.
|
269 |
Material Self-Fashioning and the Renaissance Culture of ImprovementLodhia, SHEETAL 27 September 2008 (has links)
This dissertation argues that in Renaissance discourses of the body the body is progressively evacuated of the spirit, as we move from texts of the late Medieval period to texts of the Jacobean period. Where New Historicists have suggested that the practice of “self-fashioning,” which dictates behaviour, speech and dress, takes place in the Renaissance, I argue that there was a material self-fashioning of the body occurring simultaneously. Such corporeal fashioning, motivated by desire for physical improvement, frustrates the extent to which the soul shapes the body. My Introduction lays theoretical and historical groundwork, situating the body/soul relationship in relation to Christian theology, Senecan-Stoicism, Epicureanism and philosophical materialism. Discourses of artistic creation, informed by neo-Platonism, also influence corporeal fashioning in that the most radical bodily modifications are imagined through literature, where artificers are often privileged as creators. Chapter One examines “The Miracle of the Black Leg,” a transplant, by the doctor-Saints Cosmas and Damian, of a Moor’s black leg to a white Sacristan, whose gangrenous leg is amputated. In written and pictorial representations Cosmas and Damian, initially figured as Saints, are later presented as doctors who perform a medical procedure. Alongside the doctors’ increasing agency, the black leg itself, inflected by Renaissance notions of Moors and Moorishness, troubles the soul’s immanence in the body. Chapter Two examines Elizabeth I’s practices of bodily fashioning through her wigs, dentures and cosmetics. I argue that Elizabeth’s symbolic value, which includes components of monarchical rule, as well as attitudes toward female beauty, is always already pre-empted by her body. In Book III of The Faerie Queene, moreover, Edmund Spenser writes an alternative history of England through Britomart’s body to provide an heir to Elizabeth’s otherwise heirless throne. Chapters Three and Four perform close readings of Book II of The Faerie Queene, Thomas Tomkis’s Lingua, Thomas Middleton’s The Maiden’s Tragedy and Revenger’s Tragedy, and John Webster’s The Duchess of Malfi. I argue that both the allegorical and theatrical modes demand a level of materialism that paradoxically makes the body the centre of attention, and anticipates Cartesian mechanistic dualism. / Thesis (Ph.D, English) -- Queen's University, 2008-09-25 22:59:31.67
|
270 |
A média complexidade no quadro da Política Nacional de Saúde Bucal: uma abordagem do seu processo de desenvolvimento em uma perspectiva regional / The medium complexity in the National Oral Health Policy: an approach to the development process under a regional perspectiveRenata Ferraiolo Peixoto Fortuna 26 April 2011 (has links)
Esta tese tem por objeto o processo de regionalização das ações de média complexidade e da oferta de próteses dentárias no âmbito da Política Nacional de Saúde Bucal (PNSB). Foram realizadas duas pesquisas fundamentais para o entendimento desse processo: a primeira esteve voltada para o levantamento da descrição da oferta de ações especializadas e de próteses dentárias nos Planos Diretores de Regionalização (PDR) nas 27 unidades federadas do país. A segunda pesquisa verificou a cobertura por Equipes de Saúde Bucal (ESBs) na Estratégia de Saúde da Família (ESF) e a distribuição dos 844 Centros de Especialidades Odontológicas (CEOs) e dos 526 Laboratórios Regionais de Próteses Dentárias (LRPDs) implantados até setembro de 2010 nas regiões de saúde do Brasil dos 27 estados da federação. Essas pesquisas permitiram concluir que: os PDRs, na grande maioria dos estados brasileiros, não contribuíram para a organização regionalizada da distribuição de CEOs e LRPDs no Brasil. A cobertura por Equipes de Saúde Bucal é heterogênea, com predominância da Região Nordeste e dos municípios de pequeno porte, em detrimento das capitais e dos estados das regiões Sul e Sudeste. No tocante à distribuição das unidades CEO e LRPD pelas regiões de saúde, a pesquisa mostrou que os critérios normativos para a seleção dos municípios a sediarem essas unidades vêm sendo cumpridos de forma precária na maior parte do país. Além disso, a distribuição dessas unidades não apresenta coerência com os princípios da regionalização prevista pelo Pacto de Gestão do SUS. / This thesis analyzes the process of regionalization of medium complexity actions and the supply of dental prostheses in the National Oral Health Policy (PNSB). Two main surveys were made for the understanding of this process: the first was aimed at describing the offer of specialized actions and dental prostheses according to the Regionalization Master Plans (PDR) in 27 federal units of the country. The second study examined the coverage by Oral Health Teams (ESBs) in the Family Health Strategy (ESF) and the distribution of 844 Specialized Dental Centers (CEOs) of 526 Regional Laboratories of Dental Prostheses (LRPDs) deployed by September 2010 in the Brazilian health regions in 27 states. These surveys showed that: the PDRs, in the vast majority of Brazilian states, have not contributed to the organization of regionalized distribution of CEOs and LRPDs in Brazil. Coverage by ESBs is heterogeneous, mostly in the Northeastern Region and in small towns, at the expense of the capital and the Southern and Southeastern states. Regarding the distribution of CEO and LRPD units by health regions, the survey showed that the normative criteria for the selection of municipalities to settle these units have been precariously completed in most of the country. Moreover, the distribution of those units is not consistent with the regionalization principles provided by the SUS Management Pact.
|
Page generated in 0.0618 seconds