241

Desenvolvimento de m?todos construtivos e de novos materiais empregados na confec??o de cartuchos de pr?teses de membros inferiores

Queiroz, William Fernandes de 07 August 2008 (has links)
Made available in DSpace on 2014-12-17T14:57:47Z (GMT). No. of bitstreams: 1 WilliamFQ.pdf: 3530709 bytes, checksum: e7ebfa713499f96e35732090f0094f3f (MD5) Previous issue date: 2008-08-07 / The manufacture of prostheses for lower limb amputees (transfemural and transtibial) requires the preparation of a cartridge with appropriate and custom fit to the profile of each patient. The traditional process to the patients, mainly in public hospitals in Brazil, begins with the completion of a form where types of equipment, plugins, measures, levels of amputation etc. are identified. Currently, such work is carried out manually using a common metric tape and caliper of wood to take the measures of the stump, featuring a very rudimentary, and with a high degree of uncertainty geometry of the final product. To address this problem, it was necessary to act in two simultaneously and correlated directions. Originally, it was developed an integrated tool for viewing 3D CAD for transfemoral types of prostheses and transtibial called OrtoCAD I. At the same time, it was necessary to design and build a reader Mechanical equipment (sort of three-dimensional scanner simplified) able to obtain, automatically and with accuracy, the geometric information of either of the stump or the healthy leg. The methodology includes the application of concepts of reverse engineering to computationally generate the representation of the stump and/or the reverse image of the healthy member. The materials used in the manufacturing of prostheses nor always obey to a technical scientific criteria, because, if by one way it meets the criteria of resistance, by the other, it brings serious problems mainly due to excess of weight. This causes to the user various disorders due to lack of conformity. That problem was addressed with the creation of a hybrid composite material for the manufacture of cartridges of prostheses. Using the Reader Fitter and OrtoCAD, the new composite material, which aggregates the mechanical properties of strength and rigidity on important parameters such as low weight and low cost, it can be defined in its better way. Besides, it brings a reduction of up steps in the current processes of manufacturing or even the feasibility of using new processes, in the industries, in order to obtain the prostheses. In this sense, the hybridization of the composite with the combination of natural and synthetic fibers can be a viable solution to the challenges offered above / A fabrica??o de pr?teses para amputados de membros inferiores (transfemural e transtibial) exige a confec??o de um cartucho com encaixe adequado e personalizado ao perfil de cada paciente. O processo tradicional de atendimento a pacientes, principalmente, em hospitais p?blicos no Brasil, inicia-se com o preenchimento de uma ficha onde s?o identificados os n?veis de amputa??o, tipos de equipamentos, encaixes, medidas etc. Atualmente, esse trabalho ? realizado de forma manual utilizando-se fitas m?tricas comuns e paqu?metro de madeira para tomada das medidas do coto caracterizando um trabalho bastante rudimentar, e com um alto grau de incerteza geom?trica do produto final. Para abordar esse problema foi necess?rio partir em duas dire??es simult?neas e correlatas. Inicialmente desenvolveu-se uma ferramenta integrada CAD de visualiza??o 3D para pr?teses dos tipos transfemoral e a transtibial denominado OrtoCAD I. Ao mesmo tempo em que se fez necess?rio projetar e construir um equipamento Leitor Mec?nico (esp?cie de scanner tridimensional simplificado) capaz de obter, automaticamente e com acuracidade, as informa??es geom?tricas do coto ou da perna sadia. A metodologia inclui a aplica??o de conceitos de engenharia reversa para gerar computacionalmente a representa??o do coto e/ou a imagem reversa do membro sadio. Os materiais usados na fabrica??o dessas pr?teses nem sempre obedecem a um crit?rio t?cnico cientifico, pois se por um lado atende ao crit?rio de resist?ncia por outro traz s?rios problemas devido principalmente ao excesso de peso. Isso causa diversos transtornos ao usu?rio devido ? falta de conformidade. Esse problema foi abordado com a cria??o de um material comp?sito hibrido para fabrica??o de cartuchos de pr?teses. Com o uso do Leitor Mec?nico e do OrtoCAD I o novo material comp?sito, que agrega as propriedades mec?nicas de resist?ncia e rigidez com par?metros importantes como baixo peso e baixo custo, pode ser dimensionado de forma correta. Alem disso consegue-se uma redu??o de etapas nos atuais processos de fabrica??o ou at? mesmo a viabilidade de uso de novos processos, no ?mbito industrial, na obten??o das pr?teses. Neste sentido, a hibridiza??o do comp?sito com a combina??o entre fibras sint?ticas e naturais pode ser uma solu??o vi?vel aos desafios propostos acima
242

O uso de técnicas de realidade virtual e aumentada na simulação de prótese de membros superiores

Nogueira, Kenedy Lopes 27 July 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this days with a great technological development of sciences in general, the humanity possesses more resources to promote a long and healthful life. New techniques are created to increase the life quality, however still many areas need research, one of these are the recovery of amputated patients to prostheses. The technology of prostheses construction is in constant research but the patients adaptation to these prostheses is slow and tiring. In this way this dissertation has as objective to investigate computational techniques that support simulations and training of prostheses through the interaction with a graphical interface that will stimulates patients to the use of prostheses For this the use of Virtual Reality (VR) and Augmented Reality (AR) techniques, valued for the power of immersion, interaction and navigation. Initially, it has accomplished a review of the main characteristics of the classification systems and simulation of upper limbs movements. Basing in these studies, the limitations of the existing systems were determined in terms of the virtual environments exhibition. A system was proposed to possible the users to overcome the difficulties of there deficiency. With that, the integration of the acquisition systems was obtained through a 3D graphical interface with high interaction level. With the members movements classification and the biomedical signal analysis, such as Electromyography, signal proceeding from the muscular contractions very used in the biomechanics prostheses control. / Atualmente com o grande desenvolvimento tecnológico das ciências em geral, a humanidade busca recursos para promover uma vida longa e saudável, novas técnicas são criadas para aumentar a qualidade de vida das pessoas, contudo ainda existem muitas áreas que necessitam de pesquisas, uma destas é a recuperação de pacientes amputados a próteses. A tecnologia de construção de próteses está em constante pesquisa, mas a adaptação dos pacientes a essas próteses é lenta e desgastante, neste sentido essa dissertação tem como objetivo investigar técnicas computacionais que suportem simulações e treinamento de próteses através da interação com uma interface gráfica que estimule pacientes ao uso de próteses para isso o a adoção de técnicas de Realidade Virtual (RV) e Realidade Aumentada (RA), consagradas pelo poder de imersão, interação e navegação. Inicialmente, realizou-se um levantamento das características dos sistemas de classificação e simulação dos movimentos de membros superiores. Com base nestes estudos, procurou-se definir as limitações dos sistemas existentes em termos da exibição em ambientes virtuais. Propôs-se um sistema que possibilite aos usuários superar as dificuldades da sua deficiência. Com isso, obteve-se a integração de sistemas de aquisição através de uma interface gráfica tridimensional (3D). Com a classificação dos movimentos dos membros a partir da análise de um sinal Biomédico mais especificamente Eletromiograma, proveniente das contrações muscular muito utilizado no controle de próteses biomecânicas. / Mestre em Ciências
243

Fixação de prótese facial em pacientes oncológicos: revisão sistemática

Rosa, Flávia Gabriela 16 July 2007 (has links)
The methods of fixation of the facial prostheses, it has been developing for larger comfort and safety, improving the quality and the patients' life. Consulting the information informs on the theme, there was the coincidence of subjects studied in some of these goods, having, also the disagreement possibility in their conclusions. The objective of this study was to evaluate the fixation methods (implants extra orals and stickers) of facial prosthesis in patient of cancer, through a systematic review (Meta analysis). Searches were accomplished by rehearsals controlled randomized of studies about fixation of facial prosthesis in patient of cancer through stickers and implants facial in bases of bibliographical data. It was located 259 summaries that were read and selected by two examiners, according to eligibility criteria and quality. The clinical endings of fixation mechanic's methods and anatomical, it was not possible to accomplish methanalysis. For the studies whose fixation method was adhesive and facial implants, it took place methanalysis eleven goods, selected were considered eligible and presenting quality for the study, involving 787 patient that do use of facial prosthesis. The methanalysis shows evidences of the beneficial effects of the use of implants extra orals for retention of the facial prostheses. The good effectiveness of the fixation methods is evidenced by implants extra orals, but for cases where no there is a good selection of the bone type and all is not possible the placement of implants the stickers is an alternative to keep the prostheses facial. / Os métodos de fixação das próteses faciais têm evoluído para maior conforto e segurança, melhorando a qualidade de vida dos pacientes. Consultando as informações cientificas sobre o tema, houve a coincidência de assuntos estudados em alguns destes artigos, havendo, também a possibilidade de discordância nas suas conclusões. O objetivo deste estudo foi avaliar os métodos de fixação (implantes extra-orais e adesivos) de próteses faciais em pacientes oncológicos, por intermédio de uma revisão sistemática (meta análise). Foram realizados buscas por ensaios aleatorizados controlados de estudos sobre fixação de prótese facial em pacientes oncológicos por meio de adesivos e implantes extra orais em bases de dados bibliográficos. Localizouse 259 resumos que foram lidos e selecionados por examinadores, segundo critérios de elegibilidade e qualidade. Para os desfechos clínicos dos métodos de fixação por adesivos, não foi possível realizar metanálise. Para os estudos cujo método de fixação eram adesivos e implantes faciais, realizou-se metanálise. Dez artigos, selecionados foram considerados elegíveis e apresentando qualidade para o estudo, envolvendo 787 pacientes que fazem uso de prótese facial. A metanálise mostra evidencia dos efeitos benéficos do uso de implantes extra orais para retenção das próteses faciais. Para casos onde não há quantidade e qualidade óssea e onde foi submetido a tratamento radioterápico, quando não for possível a colocação de implantes, os adesivos são uma alternativa para reter próteses faciais, mas pode trazer irritação a pele quando usado por um longo período. / Mestre em Odontologia
244

Contribution de l'IRM à l'analyse de la physiologie de la déglutition et des dysphagies oropharyngées : étude fonctionnelle des prothèses intra-laryngées / Contribution of cine-MRI to the physiology of swallowing and oro-pharyngeal dysphagia : functional study of intra-laryngeal prostheses

Guilleré, Florence 06 September 2013 (has links)
Ces travaux ont pour objectif, à partir de l’analyse en ciné-IRM du processus de déglutition salivaire chez un sujet sain, d’optimiser le rendement clinique de cette technique pour les dysphagies. Un protocole d’imagerie rapide et une grille d’évaluation (D-GRID) ont été conçus. Leur application a été étudiée chez des patients présentant une tumeur des voies aéro-digestives supérieures, et chez des patients porteurs de Prothèses Intra-Laryngées (PIL). LaD-GRID permet de mesurer et d’évaluer le mécanisme de protection des voies aériennes, de concevoir des programmes de réhabilitation et de suivre l’évolution des dysphagies. L’analyse de la déglutition en ciné-IRM est limitée par l’absence de bolus et la position de decubitus dorsal, mais nos résultats montrent sa fiabilité. La ciné-IRM définit des modèles du déplacement normal ou anormal des structures anatomiques au cours de la déglutition.Les données de l’imagerie dynamique contribuent au développement des PIL. / The aim of this study was to develop the use of fast imaging to assess the swallowing mechanism in healthy volunteers, and to optimize its clinical use in case of oro-pharyngeal dysphagia. A fast imaging protocol during dry swallowing and an evaluation grid (D-GRID) were designed. Healthy subjects, patients with head and neck canceror patients implanted with intra-laryngeal prostheses under went kinetic MRI. True-FISP sequences provide accurate information about morphological aspects of the oro-pharyngo-larynx and displacements of anatomical structures involved in the normal or impaired swallowing mechanism. The analysis of the swallowing process with cine-MRIis restricted because of the lack of bolus and the supine position, but our outcomes are reliable. Patterns of normal orabnormal anatomical structures movements during swallowing are determined by cine-MRI. The development ofIntra-Laryngeal Prostheses represents a therapeutic solution partly based on dynamic MRI data.
245

Avaliação de dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e barra articulada / Evaluation of two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated Bar

Rafael Cândido Pedroso e Silva 27 January 2016 (has links)
O objetivo deste estudo foi avaliar dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e Barra Articulada. Após ciclagem termomecânica, foram analisadas a perda de torque dos parafusos protéticos e adaptação marginal vertical e horizontal. Ao final, as próteses foram submetidas a ensaios de fadiga acelerada progressiva e resistência à fratura. Foram confeccionadas 48 próteses totais fixas implantossuportadas, as quais foram divididas inicialmente em dois grupos, G1 protocolo convencional; G2 - &ldquo;All-on-4&rdquo;. De acordo com a técnica de fabricação das infraestruturas, estes grupos foram divididos em três subgrupos, A - tecnologia CAD-CAM; B - fundição convencional; C - Barra Articulada, proporcionando seis amostragens diferentes: G1A, G1B, G1C, G2A, G2B e G2C (n=8). Todas as próteses foram avaliadas em relação à adaptação marginal vertical e horizontal, utilizando MicroCT, antes e após a ciclagem termomecânica (2.000.000 de ciclos). A perda de torque dos parafusos protéticos foi analisada antes (T0), após 1.000.000 (T1) e 2.000.000 de ciclos (T2). Após este ensaio, as próteses foram submetidas ao teste de fadiga acelerada progressiva (n=8) e em sequência, ensaio de resistência à fratura (n=6). A perda de torque teve diferença significante para todos os tempos comparados (p<0,01), exceto em G2B, onde a comparação entre T1 - T2 não mostrou diferença significante (p=0,72). A comparação entre G1 e G2 não foi significante. A comparação entre os subgrupos A, B e C teve diferenças significantes em G1T1, G1T2, G2T1 e G2T2 quando comparados os subgrupos A - B e B - C, todos com (p<0,01). Não houve diferenças significantes para a adaptação marginal vertical e horizontal antes e depois da ciclagem em todos os grupos. Na comparação de G1 e G2, houve diferença significante para a adaptação vertical e horizontal apenas no subgrupo B, nos dois tempos, ambos com (p <0,01). Na comparação dos subgrupos A, B e C, houve diferenças significantes em G1 antes e depois; e G2 antes e depois, quando comparados os subgrupos A - B e B - C, todos com (p<0,01) para a adaptação vertical e horizontal. Já para a adaptação horizontal, esta comparação foi significante apenas em G2 antes e depois, ambos com (p=0,02). Em relação à resistência à fratura, a comparação entre G1 e G2, foi significante em todos os subgrupos, A e C (p<0,01), B (p=0,02). A comparação dos subgrupos A, B e C, também foi significante em relação à resistência à fratura das próteses em todos os grupos (p<0,01). Pode-se concluir que a simulação de ciclos mastigatórios teve influência significante sobre a perda de torque dos parafusos protéticos, porém não influenciou significativamente a adaptação marginal vertical e horizontal das próteses; desadaptações marginais influenciaram significativamente no afrouxamento dos parafusos protéticos; as próteses dos subgrupos A e C obtiveram resultados significantemente melhores para a adaptação marginal vertical e horizontal quando comparadas às do subgrupo B, sendo que na adaptação horizontal, as do subgrupo A tiveram resultados melhores que as do C; a quantidade e distribuição dos implantes não influenciou na perda de torque dos parafusos protéticos em todas as situações, porém teve influência significativa na adaptação marginal vertical e horizontal das próteses do subgrupo B; todas as próteses sobreviveram ao ensaio de fadiga acelerada progressiva; em relação ao ensaio de resistência à fratura, as próteses do G2, tiveram resultados significantemente melhores que as do G1, o subgrupo B obteve valores significantemente maiores de resistência na região do cantilever, quando comparadas ao subgrupos A e C; o subgrupo A obteve os menores valores de resistência. / The objective of this study was evaluate two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated Bar. After thermomechanical cycling, were analyzed prosthetic screws loosening and vertical and horizontal marginal adaptation. In the end, the prostheses were submitted to tests of progressive accelerated fatigue and fracture resistance. Were made 48 implant-supported fixed dentures, which initially were divided into two groups, G1 - conventional protocol; G2 - \"All-on-4\". According to the technique of manufacturing infrastructure, these groups were divided into three subgroups: A - CAD-CAM technology; B - conventional casting; C - Articulated bar, providing six different samples: G1A, G1B, G1C, G2A, G2B e G2C (n=8). All samples were evaluated in the vertical and horizontal marginal adaptation using MicroCT before and after the thermomechanical cycling (2,000,000 cycles). The loosening of the prosthetic screws was analyzed before (T0), 1,000,000 (T1) and 2,000,000 cycles (T2). After this test, the prostheses were submitted to progressive accelerated fatigue test (n = 8) and sequentially fracture resistance test (n = 6). The prosthetic screw loosening has significant difference for all time compared (p <0.01), except in G2B where the comparison between T1 - T2 showed no significant difference (p = 0.72). The comparison between G1 and G2 was not significant. The comparison between subgroups A, B and C had significant differences in G1T1, G1T2, G2T1 and G2T2 compared subgroups A - B, B - C, all of (p <0.01). There were no significant differences for vertical and horizontal marginal adaptation before and after cycling in all groups. Compared to G1 and G2, there was a significant difference for vertical and horizontal adjustment only in the subgroup B in two stages, both (p <0.01). In the comparison of subgroups A, B and C, there were significant differences G1 before and after; and G2 before and after, when compared subgroups A - B, B - C, all of (p <0.01) for vertical and horizontal adaptation. As for the horizontal adaptation, this comparison was significant only in G2 before and after, with both (p = 0.02). With regard to fracture resistance, the comparison between G1 and G2 was significant in all subgroups, A and C (p <0.01), B (p = 0.02). The comparison of subgroups A, B and C was also significant compared to the fracture resistance of the prosthesis in all groups (p <0.01). It can be concluded that the simulation of mechanical cycling had significant influence on the loosening of prosthetic screws, but did not significantly influence the vertical and horizontal marginal fit of the prosthesis; marginal adaptation significantly influenced the loosening of prosthetic screws; the prostheses of the subgroups A and C had significantly better results for the vertical and horizontal marginal adaptation when compared to the subgroup B, and in the horizontal adaptation, the sub-group A had better results than those of C; the amount and distribution of the implants did not affect the prosthetic screws loosening in all situations, but had significantly influence in vertical and horizontal marginal adaptation of subgroup B prostheses; all samples survived in progressive accelerated fatigue test; in relation to the fracture resistance test, the prosthesis G2, had significantly better results than the G1, the B subgroup achieved significantly higher values of resistance in the cantilever region, when compared to subgroups A and C; the subgroup C obtained the smallest resistance.
246

Efeito do design da união soldada a TIG e a laser, em estruturas usinadas em liga de Ti-6AI-4V e fundidas em titânio comercialmente puro, sobre a resistência à ciclagem mecânica / Effect of TIG and laser welded joints with different designs executed in machined Ti-6Al-4V and casted pure titanium strutures on the mechanical cycling resistance

Nuñez-Pantoja, Juliana Maria Costa 17 August 2018 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T15:29:22Z (GMT). No. of bitstreams: 1 Nunez-Pantoja_JulianaMariaCosta_D.pdf: 1479308 bytes, checksum: ee8715e20b041116b795969befba2c72 (MD5) Previous issue date: 2011 / Resumo: Este estudo avaliou a resistência à ciclagem mecânica de estruturas confeccionadas em liga de Ti-6Al-4V e em Ti cp, submetidas à soldagem a laser (L) e ao procedimento TIG de soldagem (TIG), com variação de design das uniões, e correlacionar esses resultados com dados obtidos na análise radiográfica dessas soldas. Para o primeiro ensaio, foram obtidos 70 corpos de prova (halteres) usinados em liga de Ti-6Al-4V, com 3,5 mm de diâmetro de secção transversal e, para o segundo ensaio, outros 70 foram fundidos em Ti cp. Os corpos de prova foram seccionados em duas partes iguais e as partes a serem unidas foram limpas e alinhadas, segundo os designs da união: em "I", variando as distâncias de soldagem (0,0mm (I00) ou 0,6mm (I06)), ou em "X" (X). As variáveis design da união e tipo de soldagem foram cruzadas entre si formando um total de 6 grupos, que associadas ao grupo controle (intactos) totalizaram 7 grupos (n=10): G1- Intacto; G2- L/I00; G3- L/I06; G4- L/X; G5- TIG/I00; G6- TIG/I06; G7- TIG/X, para cada ensaio. Os corpos de prova foram soldados a laser utilizando-se 360V/8ms (X) e 390V/9ms (I00 e I06), com foco e freqüência regulados em zero. As soldas TIG foram realizadas utilizando-se os seguintes parâmetros de soldagem: 2:2 (X) e 3:2 (I00 e I06). As uniões receberam acabamento, polimento e foram submetidas à análise radiográfica (90 kV, 15 mA, 0,6 seg e 12 mm de distância), para verificação de poros no interior das soldas. Posteriormente, foi realizado o ensaio de resistência à ciclagem mecânica, e o número de ciclos até a fratura foi registrado. As superfícies de fratura foram analisadas em microscópio eletrônico de varredura. Os testes de Kruskal-Wallis e Dunn (?=0,05) mostraram que para ambos os procedimentos de soldagem, a pior maneira de se realizar a união se dá com I00, e a melhor, com X (p<0,05), para ambos os metais. Apenas para L, I06 foi tão resistente quanto X, tanto para o Ti cp quanto para Ti-6Al-4V. Quando são comparados os dois procedimentos de união, para os dois materiais, o teste de Mann-Whitney (?=0,05) mostrou haver diferença entre as soldas para I00 e I06, sendo que a união soldada a laser foi a mais resistente. Quando foram comparados os grupos com seus respectivos controles, notou-se que para o Ti-6Al-4V, nenhum grupo soldado foi tão resistente quanto os intactos; já para o Ti cp, os grupos com design X, para as duas soldas, foram tão resistentes quanto o controle, assim como o I06 soldado a laser. O coeficiente de correlação de Spearman (?=0,05) indicou correlação negativa entre número de ciclos resistidos e presença de poros nas radiografias das uniões dos materiais testados. Pode-se concluir que a união soldada com design em "X" dev0e ser empregada quando se pretende soldar a TIG corpos de prova de 3,5 mm de diâmetro de secção transversal. Quando é empregada a solda a laser, pode ser utilizado o design em "I" com 0,6 mm de espaçamento entre as partes, além do design em "X". / Abstract: The aim of this study was to evaluate the fatigue strength of Ti-6Al-4V alloy and pure titanium (cp TI) structures, submitted to laser (L) and TIG (TIG) welding procedures, varying the design of the joints, and correlate these results with joints radiographic analyses data. For the first test, 70 dumbbell rods with central diameters of 3.5 mm were obtained by lost-wax casting procedure in cp Ti, and others 70 were machined in Ti-6Al-4V alloy, for the second test. The specimens were sectioned in 2 equal parts, perpendicular to the rods long axis. The parts to be weld were cleaned and aligned according to joint designs: "I" design, varying welding distances (0.0 mm (I00) or 0.6 mm (I06)), or "X" (X) design. The variables joint design and type of welding were crossed creating 6 groups, that associated to the control group (intact), totaled 7 groups (n=10): G1- Intact; G2- L/I00; G3- L/I06; G4- L/X; G5- TIG/I00; G6- TIG/I06; G7- TIG/X, to each test. Laser-welding was executed using 360V/8ms (X) and 390V/9ms (I00 e I06) with focus and frequency regulated at zero. The TIG welding were executed using 2:2 (X) and 3:2 (I00 and I06) as welding parameters. The joints were finished, polished and submitted to radiographic examination (90 kV, 15 mA, 0.6 second and 12 mm of distance), for pores verification within the joints. Later, the rods were submitted to mechanical cyclic tests, and the number of cycles until fracture was recorded. The fracture surface was examined with a scanning electron microscope. Kruskal-Wallis and Dunn test (?=0.05) indicated that for both welding procedures, the worst way to perform the joint occurs with I00, and the best, with X (p<0.05), for both metals. To L, I06 was as resistant as X. When both type of welding are compared, to both materials, the Mann-Whitney test (?=0.05) indicates difference to I00 and I06, being the laser-weld joint the better one. When groups were compared with their respective control groups, it was noticed for Ti-6Al-4V that none of the joint groups was as resistant as the intact; on the contrary to cp Ti the "X" design groups, welded by TIG or L were as resistant as control, even as I06 laser-welded. The Spearman correlation coefficient (?=0.05) indicated a negative correlation between number of cycles and presence of porosity in radiographies of both materials. It could be concluded that the "X" design can be employed to weld 3.5 mm in diameter structures by laser or TIG welding procedure. When laser welding procedure is used, the "I" design with a space of 0.6 mm between parts can also be employed. / Doutorado / Protese Dental / Mestre em Clínica Odontológica
247

Estudo da resistência à corrosão do aço inoxidável ferrítico AISI 444 para aplicação como biomaterial / Study on the corrosion resistance of AISI 444 stainless steel for application as biomaterial

MARQUES, ROGERIO A. 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T14:30:57Z No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T14:30:57Z (GMT). No. of bitstreams: 0 / Os aços inoxidáveis ferríticos são naturalmente ferromagnéticos, o que impossibilita sua utilização em próteses ortopédicas. Apesar disso, em algumas aplicações específicas, faz-se necessário o uso de um biomaterial ferromagnético, como nas próteses odontológicas e faciais com conectores magnéticos. Este trabalho apresenta o estudo da resistência à corrosão e citotoxicidade do aço inoxidável ferrítico AISI 444, para avaliar seu potencial de uso como um biomaterial. O aço AISI 444 possui baixo teor de níquel, teores extrabaixos de intersticiais (C e N) e é estabilizado com Ti e Nb. Como materiais de referência foram utilizados o aço inoxidável austenítico ISO 5832-1 (ASTM F-138), por ser o biomaterial metálico mais empregado na fabricação de próteses ortopédicas, e uma base ferromagnética do sistema de fixação de próteses odontológicas, feita em aço inoxidável ferrítico (NeoM). O ensaio de citotoxicidade in vitro, pelo método de incorporação do corante vermelho neutro, revelou que o aço inoxidável AISI 444 não apresentou citotoxicidade. O comportamento frente à corrosão foi estudado por meio de curvas de polarização anódica potenciodinâmicas e espectroscopia de impedância eletroquímica (EIE). O meio de ensaio foi uma solução salina tamponada de fosfato (PBS), em condição naturalmente aerada e em fresta, a temperatura de 37 ºC. Para simular a condição de fresta dos ensaios eletroquímicos foi desenvolvido um novo equipamento. As propriedades eletrônicas do filme passivo foram avaliadas pela técnica de Mott-Schottky. Em meio aerado, os resultados de EIE indicaram que todos os materiais se mostraram passivos. As curvas de polarização indicaram que a resistência à corrosão por pite do aço AISI 444 foi equivalente à do aço ISO 5832-1, porém superior à do NeoM. Pelos diagramas de Mott-Schottky, conclui-se que o filme óxido no aço AISI 444 possui menor concentração de dopantes que o aço NeoM. Isto sugere que o aço AISI 444 apresenta maior resistência à transferência de carga através do filme passivo. Em condição de fresta, as polarizações indicaram taxas de corrosão baixas para ambos os aços, porém superiores para o aço ISO 5832-1, em comparação ao aço AISI 444. As micrografias das superfícies dos aços, após polarização, revelaram um maior ataque corrosivo no aço ISO 5832-1 do que no aço AISI 444. O aço NeoM apresentou composição química fora da especificação da norma. Os baixos teores de Cr e de Mo, além das altas concentrações de sulfetos, foram as prováveis causas da menor resistência à corrosão do NeoM, indicada pelos ensaios eletroquímicos. O equipamento proposto para avaliação da resistência à corrosão, em condição de fresta, mostrou boa reprodutibilidade de resultados. O aço inoxidável AISI 444 apresentou alta potencialidade para uso como biomaterial, especialmente na fabricação de componentes protéticos com fixação magnética. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
248

ANÃLISE DE SISTEMAS DE IMPLANTES DENTÃRIOS EM MANDÃBULAS EDÃNTULAS COM APLICAÃÃO DE CARREGAMENTO IMEDIATO / Study of the systems of dental implantations for edentulous mandibula with immediate load

Luiz Carlos GonÃalves Pennafort Junior 30 October 2009 (has links)
O presente estudo teve por objetivo obter elementos comparativos entre os sistemas guiados de prÃteses totais fixas com 4 implantes osteointegrÃveis com aplicaÃÃo de carga imediata, tendo em vista a importÃncia de se entender o projeto dos implantes como um processo em que se avaliem os biomateriais e a biomecÃnica. Utilizou-se o mÃtodo dos elementos finitos tridimensionais para analisar as concentraÃÃes de tensÃes em todo o sistema implantossuportado, associado à variaÃÃo do material de confecÃÃo da barra protÃtica entre as ligas de Niquel-Cromo, Cobalto-Cromo e Ti-6Al-4V, sendo realizados ensaios metalogrÃficos das ligas de Ni-Cr e Co-Cr, no intuito de identificar a microestrutura e consequentemente avaliar sua influÃncia no comportamento mecÃnico do sistema. Foram analisados dois sistemas, sendo um com cantilever e outro sem, porÃm com uso de implantes inclinados, submetidos a um carregamento vertical de 756 N sobre toda face superior da barra protÃtica implantossuportada. Paralelamente a este estudo tambÃm foram verificados separadamente os conjuntos protÃticos (parafuso-pilar-implante) reto e inclinado submetidos a uma carga vertical de 100N sobre o topo do pilar. Os dados encontrados foram comparados e avaliados de acordo com valores obtidos na literatura Os resultados demonstraram que a utilizaÃÃo de implantes inclinados evitando a utilizaÃÃo do cantilever, diminuiu consideravelmente os nÃveis de tensÃes na barra protÃtica e nos pilares, porÃm na regiÃo implante-osso, observou-se um aumento de aproximadamente 1,5 vezes, em relaÃÃo aos implantes retos sob cantilever. O estudo das ligas apontou a liga de Co-Cr como um material de desempenho considerÃvel em relaÃÃo Ãs demais ligas, quanto ao comportamento mecÃnico. / The present study aimed at obtaining comparative elements among the guided systems of fixed complete denture with 4 osseointegrated implants with immediate loading, considering the importance of understanding the implant project as a process where biomaterials and biomechanics are assessed. The three-dimensional finite element method was used to analyze the stress concentrations in the whole implant-supported system, associated to the variation of the material of the prosthetic bar among the nickel-chromium, cobalt-chromium and Ti-6Al-4V alloys. Metallographic tests of the Ni-Cr and Co-Cr alloys, were made with the objective of identifying the micro-structure and consequently evaluate its influence in the mechanical behavior of the system. Two systems were analyzed, one with cantilever and another without it, but with tilted implants, submitted to a vertical load of 756N on the superior face of the prosthetic implant-supported bar. Parallel to this study the prosthetic groups (screw-abutment-implants) straight and tilted were also separately verified, submitted to a vertical load of 100N on the top of the abutment. The data found were compared and assessed according to values obtained in the literature. The results demonstrated that the use of tilted implants avoiding the use of cantilever reduced considerably the stress levels in the prosthetic bar and in the abutments. However, in the implant-bone area an increase of approximately 1.5 times in stress levels was observed, compared to the straight implant under cantilever. The study of the alloys apponted the Co-Cr alloy as a material comparable to the other ones, regarding the mechanical behavior
249

Avaliação da força de repulsão entre magnetos de neodímeo ferro boro usados em tratamentos intra e extra bucais / Evaluation of repulsion force between Neodymium Iron Boron magnets used for intra and extra oral treatments

Renato Sartori Lardin Sanchez 15 February 2012 (has links)
Os magnetos de Neodímio Ferro Boro (Nd2Fe14B) apresentam excelentes propriedades magnéticas e compatibilidade biológica, embora sejam frágeis e possuam baixa resistência à corrosão. As forças de atração magnética de magnetos de terras raras têm sido empregadas em sistemas de retenção, principalmente associadas aos implantes osseointegráveis, em próteses bucais e próteses faciais, bem como em aparelhos ortodônticos. Este estudo avalia o comportamento das forças de repulsão magnética, em função do volume e comprimento do eixo magnético, quando submetidos a afastamentos, de modo que esta propriedade física seja empregada em odontologia. Vinte e quatro corpos de prova, com um ou dois pares de magnetos de Nd2Fe14B, com diferentes formas e volumes variados, foram submetidos a ensaio mecânico para mensuração das forças de repulsão magnética, em condições de afastamentos que variaram entre 0,0 e 20,0 mm. Os dados observados mostram que, considerando-se uma mesma área superficial de polo, a força de repulsão magnética varia em função do comprimento do eixo magnético. Os dados relativos ao afastamento foram submetidos a análise de variância (p0,05), tendo-se observado que o aumento da distância entre os magnetos diminui significantemente a força de repulsão magnética na maioria dos corpos de prova. No afastamento 0,0 mm as forças magnéticas de repulsão dos subgrupos mantêm uma sequência crescente a partir do subgrupo de menor volume de magnetos ao subgrupo de maior volume de magnetos, os quais permanecem nessa sequência nos afastamentos iniciais. A força de repulsão magnética gerada por magnetos pequenos varia menos em função do aumento do afastamento. Conclui-se que a variação da força de repulsão magnética, dada a mesma área superficial de polo, apresenta uma relação direta com o volume e com o eixo magnético onde, quanto maior o volume ou o comprimento do eixo magnético, maior a força de repulsão magnética. A relação direta entre volume e força de repulsão magnética não se altera frente aos afastamentos inicais, tendendo a se tornar imensurável com o aumento da distância. A força de repulsão magnética mantém uma relação inversa com a distância entre os pares de magnetos. Este ensaio mecânico indica que a força de repulsão magnética apresenta, assim como a força de atração magnética, uma curva hiperbólica de redução frente ao aumento do afastamento. / Neodymium Iron Boron (Nd2Fe14B) magnets exhibit excellent magnetic properties and demonstrate biological compatibility, despite of their fragility and low resistance to corrosion. The magnetic attraction forces of rare earth magnets have been used in retention systems mainly associated with osseointegrated implants, in oral and facial prostheses, as well as orthodontic appliances. This study evaluates the repulsion forces of magnets, varying volume and length of magnetic axis when subjected to vertical distance, in order to assess the usefulness of such physical property in clinical situations. Twenty-four specimens, with one or two pairs of Nd2Fe14B magnets, presenting different shapes and various volumes, were subjected to mechanical testing so as to measure magnetic repulsion forces, under conditions of vertical pole face separation ranging from 0.0 to 20.0 mm. Repulsive magnetic force varies depending on the length of the magnetic axis, when considering the same surface area of a pole. Analysis of Variance - (p0.05) indicated that by increasing the distance between the pairs of magnets, magnetic repulsion force significantly reduces in most of the specimens. Starting at a 0.0 mm distance, the magnetic repulsion forces keep an enhancing sequence from lower to higher magnetic volume, holding these characteristics during initials distances. Repulsion magnetic forces generated by small magnets varies less as the distance increases. The results indicate the repulsion magnetic force variation, fixing the same pole surface area, presenting a direct relationship between volume and magnetic axis, since the increase of the volume or of the magnetic axis length leads to a higher magnetic repulsive force. The relationship between volume and magnetic repulsion force does not vary at initial distance. Nevertheless, when such distance increases, the force between the magnets significantly decreases. The magnetic repulsion force holds an inverse relationship with respect to the distance between magnets pairs. This mechanical test indicates that the magnetic repulsion force, as well the magnetic attraction force, present a hyperbolic curve of force reduction due to the increasing vertical distance.
250

"Avaliação da retenção de coroas metálicas fundidas em função dos tipos de agentes cimentantes e das ciclagens térmica e mecânica" / Evaluation of cast crowns’ retention with two different lutting agents after thermocycling and mechanical load

Emerson Nakao 18 October 2005 (has links)
Nesta pesquisa, foram avaliados a retenção de coroas cimentadas sobre dentes terceiros molares humanos extraídos, após submetê-los às ciclagens térmica e mecânica, e o tipo de falha dos cimentos. Vinte dentes foram preparados de maneira padronizada, com 4 mm de altura, 8 mm de diâmetro e 20º de expulsividade. Coroas metálicas fundidas em NiCr foram cimentadas sobre os preparos, sendo dez com cimento de fosfato de zinco e dez com cimento resinoso, e armazenadas em água a 37ºC por 24 horas. Aleatoriamente, a metade das amostras de ambos os cimentos foi submetida a termociclagem (5ºC e 55ºC ±1ºC por 700 ciclos), seguida de ensaios mecânicos (freqüência de 2 Hz, carga compressiva de 141N por 200.000 ciclos). A outra metade das amostras (grupo controle) não foi submetida aos testes de fadiga. Realizou-se o teste de tração e os valores obtidos foram tratados estatisticamente pelo teste ANOVA (Tukey-Kramer Multiple Comparisons Test). Os resultados mostraram retenção significativamente superior do cimento resinoso Panavia F (valor médio 569,43 N) sobre o cimento de fosfato de zinco (valor médio 350 N). Os testes de envelhecimentos mostraram-se significantes (p<0,001) na sua influência sobre a retenção das coroas, exceto para o grupo cimentado com fosfato de zinco (p>0,05). A falha do cimento observada foi de natureza adesiva para todos os grupos. / The aim of this study was to evaluate the retention of NiCr cast metal crowns fixed with two different lutting agents after thermocycling and mechanical load. The nature of the cement failure was evaluated too. Twenty natural human molar teeth extracted were selected (Banco de Dentes Permanentes Humanos da Faculdade de Odontologia da Universidade de São Paulo – SP). They were prepared at 4mm height, 8mm diameter and 20º of convergence. The cast crowns were lutted with zinc phosphate cement (n=10) and resin cement (n=10) and stored in water at 37ºC for 24 hours. Randomly the half of the specimens of each cement were thermal (5ºC and 55ºC for 700 cycles) and load cycled (2 Hz, 141 N load for 200.000 cycles). The control group did not perform the thermal or fatigue tests. The pull-out test was performed and the results showed a significant (confidence interval 95%) superior retentive strength for Panavia F resin cement (mean value 569,43 N) when compared with zinc phosphate (mean value 350 N). The aging tests were significant (p<0,001) about their influence over the retention of the crowns. They was no significant difference between control and cycled group for crowns lutted with phosphate cement (p>0,05). Adhesive failure of the cements was observed for all subjects.

Page generated in 0.0703 seconds