• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 65
  • 26
  • Tagged with
  • 91
  • 30
  • 18
  • 14
  • 11
  • 9
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Att katalogisera en specialsamling med hjälp av TEI : En metodprövande studie utförd på Swedenborgsarkivet i Kungl. Vetenskapsakademien / Cataloguing a special collection by the means of TEI : A methodological study performed on the Swedenborg Archives at the Swedish Royal Academy of Sciences

Berggren, Maria January 2008 (has links)
In this thesis, the TEI (Text Encoding Initiative) encoding scheme is investigated as a system for storing metadata about manuscript material and 18th century first prints in the Swedenborg Archives at the Swedish Royal Academy of Sciences. The aim of the study is to test the functionality of TEI as a metadata system in cataloguing a special collection. Some criteria of functionality are formulated, and examples of encoded catalogue entries are described and analysed. It is demonstrated how descriptive metadata have been registered within the TEI header, while structural metadata have been recorded within the text element of the TEI file. On the whole, TEI is considered to be a functional tool that matches the present purposes. Some weaknesses are pointed to, however: For example, the TEI encoding scheme is not perceived to be fully satisfying for presenting descriptive metadata about manuscripts and prints in the same volume, and, moreover, it is not considered fully appropriate for describing abstract logical text structure in relation to the physical structure of the document. Lastly, TEI is compared to two other metadata systems, the AACR2, ch. 4, and AMREMM. A general conclusion is that the TEI offers a set of guidelines that can easily be adapted to specific needs, while a system for cataloguing in a more proper sense must also contain a set of rules concerning what categories of data are to be included, and in what form it is to be done. / Uppsatsnivå: D
22

Tryckpulsgenerering för funktionskalibrering av mätsystem / Generation of pressure pulses for calibration of measurement systems

Hagborg, Martin January 2003 (has links)
<p>The running of gas turbines with low emissions causes high pressure pulsations to arise in the combustion chamber. These pulsations are high amplitude sound vibrations. At some frequencies these are harmful to the gas turbine. Hence these pulsations are monitored to avoid operating conditions where pulsations are specifically harmful. It is necessary to expose the system of known pulsations to verify the functionality of the monitoring process. </p><p>This report describes the development of a generator of pressure pulsations to verify the monitoring system. The output should be of harmonic form with a frequency of greater than 160 Hz and 15 mbar in amplitude. To begin with, a few alternatives to a pulsation generator are described. In light of studies of these possibilities the alternative based on a roller bearing is selected. This is considered as one of the easier alternatives to design. </p><p>An existing generator of pressure pulsations has been analyzed. The calculations from this analysis supported the construction of the new device. The new generator far exceeded the specification regarding frequency, amplitude and harmonics of the pulsations. With a few modifications, such as encapsulation, the pulsation generator will be ready for usage. It could then serve as a mobile device for the inspection of the pulsation monitoring system. Possibly the device could be equipped with a faster and stronger motor. This would permit the device to be used for the calibration of pulsation monitoring sensors.</p>
23

Undersökning av metamorfa förhållanden för skarn-, metapelit- och sulfidbergarter på nordöstra Utö, Stockholms skärgård, Sverige

Antevik, Fredrik January 2013 (has links)
Detta kandidatarbete i geologi undersöker berggrunden på Utös nordöstra udde i Stockholms skärgård, med målet att fastställa metamorfa tryck-, temperatur- och fluid-XCO2-förhållanden. Utös berggrund metamorfoserades ca 1,87-1,78 Ga när en öbåge kolliderade med den arkeiska kratonen. Tidigare deponerade karbonater, vulkaniter och gråvackor blev metamorfoserade i samband med kollision och senare exstensionell kollaps. I studieområdet hittas karbonater omvandlade till marmor och skarnbergarter, som i vissa fall, troligtvis är hydrotermalt omvandlade till sulfidbergarter i samband med intrusioner i orogenesens senare skede. Gråvackor hittas omvandlade till metapeliter bärandes indexmineral. Kalcit-dolomit-termometri på tremolit-, talk- och flogopitbärande skarnbergarter gav temperaturer på 379°C respektive 412°C som kunde härledas till fluid-XCO2-koncentrationer på 0,0039 och 0,012. Geotermobarometri för metapeliter i området resulterade i osäkra tryck- och temperaturvärden p.g.a. en begränsad och retrograd mineralsammansättning, men antyder att metamorf grad tidigare varit högre. Skarn och relaterade sulfidbergarter kunde med vissa undantag klassificeras som Zn-Pb-skarn utifrån mineralogisk sammansättning av zinkblände, blyglans och pyrit. Retrograda förhållanden inom greenschist facies uppskattades utifrån framräknade temperaturer samt förekomst av reaktionstexturer.
24

Konsekvenser av rankning : En komparativ studie mellan landstingsägda och privata vårdcentraler i Uppsala

Lindberg, Clara, Lindmark, Felicia January 2013 (has links)
Rankningar är ett prestationsmått som fått ökad spridning i samhället. Studier har visat att rankningslistor kan leda till att organisationer blir lika varandra genom att det sker en anpassning till mätningarna. Det finns ett ökat intresse bland akademiska forskare och praktiker kring vilka konsekvenser rankningar får för organisationer, och det krävs vidare studier för att klargöra detta. I denna studie utforskades vilka konsekvenser rankningslistan Patienttoppen har haft för landstingsägda respektive privata vårdcentraler i Uppsala. Fyra verksamhetschefer och landstingets primärvårdsdirektör har intervjuats. Resultatet har visat på skillnader i huruvida rankningslistan har haft konsekvenser för vårdcentralerna. Det har varit variation mellan de privata vårdcentralernas konsekvenser, då rankningslistan till viss del inneburit verksamhetsförändringar för den ena vårdcentralen men inte för den andra. För de landstingsägda vårdcentralerna och primärvårdsdirektören har rankningslistan inte haft några konsekvenser.
25

Upplagstryck för träbalkar enligt Eurokod 5 - Problematik och förstärkningsåtgärder / Bearing pressure for wooden beams under Eurocode 5 - Problems with capacity and measures of reinforcement

Risén, Simon January 2013 (has links)
När Eurokod 5, standarden för dimensionering av träkonstruktioner, infördes i Sverige sågjordes det även en sänkning av hållfasthetsvärden för trä vid tryck vinkelrätt fibrerna.Tidigare kapacitet på 8 MPa för limträklass L40 var nu för högt, och den av SverigesTekniska Forskningsinstitut (SP) reviderade CE L40c fick en kapacitet på 2,7 MPa. Ettproblem i och med detta blev att byggnader som är konstruerade och uppförda enligtBoverkets föreskrifter inte längre kan utformas på samma sätt sedan Eurokodernasinförande. Syftet med arbetet blev därför att:• Ta reda på varför sänkningen skedde• Ta fram några räkneexempel på hur man kan åtgärda för låg kapacitet vid tryckvinkelrätt fibrernaLitteraturstudien som ligger till grund för arbetet visar på att sänkningen skedde på grund avatt Eurokodernas provmetod för bestämning av hållfastheten skiljer sig från den metod somBoverket använt. Den stora skillnaden ligger i att Eurokoderna inte utnyttjar lastspridning iträ, där lasten kan spridas från en träfiber till en annan intilliggande och på så vis öka denfaktiska kapaciteten. Det kan också nämnas att själva dimensioneringsprocessen inte har likastor betydelse som hållfasthetsklassningen.De beräkningar som gjordes i enlighet med arbetets andra syfte visar lämpligaförstärkningsåtgärder vid upplaget. De tre förstärkningsåtgärder som har undersökts är:• Stålplåt som läggs mellan pelare och balk för att på så vis utöka upplagslängd ochdärmed sprida upplagstrycket• Stålskruvar som skruvas in vid upplaget, tvärs fibrerna i balken• Trästavar som limmas in vid upplaget, tvärs fibrerna i balkenAlla beräkningar utfördes med 100 kN last, balktvärsnitt på 215x630 mm, pelartvärsnitt på215x150 mm och upplagslängd 150 mm.• Då stålplåtens bredd var 215 mm och med stålkvalitet s235 erhölls enligt beräkningaren plåttjocklek på15 mm och en plåtlängd på 270 mm för att klara avdimensionerande last.• För 6 st stålskruvar M12 4.6 och penetrationsdjup 400 mm erhölls enligt beräkningaren ny karakteristisk kapacitet på 5,6 MPa.• För 6 st trästavar av björk, 19 mm diameter och penetrationsdjup 400 mm erhöllsenligt beräkningar en ny karakteristisk kapacitet på 5,07 MPa. / When Eurocode 5, design rules for timber structures, was introduced in Sweden there wasalso a reduction in strength values for structural timber, and especially when it comes tocompression perpendicular to the grain. Earlier on, before Eurocode 5, the capacity ofScandinavian glulam L40 was 8 MPa which now was to be revised by the Technical ResearchInstitute of Sweden (SP). The new value was set to 2.7 MPa and the new revised glulam wasnamed CE L40c. A problem now arose, namely so that existing structures (which aredesigned after the old Swedish standard BKR) no longer can be designed in the same way.The purpose of this thesis was to:• Find out why the reduction in capacity for compression perpendicular to the grainoccurred• Make a few examples through calculations on how to fix this problemThe studies of literature which this thesis is based upon indicates that the reduction incapacity was due to the very nature of how the Eurocodes determines the strength classes,and how it is different from BKR. The big difference is that in the Eurocodes there is noutilization of the physical phenomenon where the loaded wood fibres distributes the load to anearby unloaded fibre. This phenomenon greatly increases the capacity at compressionperpendicular to the grain. It should be mentioned that this work also indicates that thedesign process does not have the same impact on the design of structures as the grading ofstrength classes has.According to the second purpose of this thesis, a set of calculations were made whichindicates appropriate methods of reinforcement of a wooden beam. The three methods are:• A steel plate which is placed between a column and a beam to increase the supportlength and therefore spread the support stress over a larger area of the beam• Steel screws which are screwed into the beam at the support, perpendicular to thegrain• Wooden rods which are glued in place inside the beam at the support, perpendicularto the grainAll calculations were made with a load of 100 kN, cross section of the beam is 215x630 mm,cross section of the column is 215x150 mm and support length is 150 mm.• When the width of the steel plate is 215 mm and steel grade s235 is used, the steelplate dimensions required are, according to calculations, thickness of 15 mm andlength of 270 mm.• With 6 steel screws, M12 4.6 and a penetration depth of 400 mm, a new characteristiccapacity of 5.6 MPa was obtained.• With 6 wooden rods made out of birch, 19 mm diameter and a penetration depth of400 mm, a new characteristic capacity of 5.07 MPa was obtained.
26

Studie av web to print samt kartläggning av kunders behov för tillämpning av systemet CiPublisher

Larsson, Anna January 2003 (has links)
Customers put their printing suppliers to severe claims for shorter production time and faster deliveries.Printers always look for new solutions to increase the satisfaction of their customers. Oneexample of such a solution is web to print, where the customers book their printed matters atInternet.The solution involves design of printed matter by using templates that are made unique for thecustomer's printed matter. Web to print is suitable for reiterated printed matters. By using templatesthe customer doesn´t have to redo their layout for every new edition. Bromma tryck AB hasinvested the system CiPublisher, which is applied for the customer to make their printed matter atInternet.The purpose of the examination work is to investigate the needs of the customers of Brommatryck for a web to print solution and how such a system should be adapted.The result shows that the customer who is in need of a web to print solution wish such a system tobe easy managed and also usable. The customer inquiry also shows that most of the customers primarydesire for start using such a solution is that it will save time and also simplify the process formanufacturing of printing matters.
27

Utvärdering av fjärrlåneverksamheten av äldre tryck

Wallin, Mathias January 2011 (has links)
Uppsatsen är en studie av fjärrlåneverksamheten av äldre tryck, med digitalisering som en valmöjlighet. Kontexten är dels utvecklingen av digitaliseringsprojekt hos bibliotek, dels det användarcentrerade förslaget hos 2010 års fjärrlåneutredning. Som fallstudier beskrivs två bibliotek i Umeå, universitetsbiblioteket och Sveriges depåbibliotek. Utvärderingens centrala fråga är om digitalisering kan vara ett passande alternativ till fjärrlån av äldre tryck, för att stärka användarvänligheten. Problembilden utgår från en frågeställning över tre områden: Hur ser fjärrlånetrafiken av äldre tryck ut? Vilka problematiska aspekter finns det kring fjärrlån? Vilka konsekvenser får ett alternativ som digitalisering? Fjärrlån utgör en mycket liten del av den totala lånesumman, och det äldre trycket av det samma en nästan obetydlig del. Kostnad, tidsåtgång och ömtålighet är aspekter av verksamheten, och ett tänkt utfall är att effektiviteten skulle öka med digitalisering, vilket samtidigt skulle innebära att kulturarvet synliggörs, vilket är digitaliseringens främsta syfte idag. Dessutom skulle användarnas önskemål leda detta tillgängliggörande, vilket svarar mot både riktlinjer över digitalisering och fjärrlåneutredningens användarbaserade målsättning. Ett försök av implementering av digitalisering i fjärrlåneverksamheten vore intressant att se, och Umeå är en passande stad för ett pilotprojekt.
28

Gal Pals in Print

Westerberg, Julia January 2017 (has links)
No description available.
29

Tryckpulsgenerering för funktionskalibrering av mätsystem / Generation of pressure pulses for calibration of measurement systems

Hagborg, Martin January 2003 (has links)
The running of gas turbines with low emissions causes high pressure pulsations to arise in the combustion chamber. These pulsations are high amplitude sound vibrations. At some frequencies these are harmful to the gas turbine. Hence these pulsations are monitored to avoid operating conditions where pulsations are specifically harmful. It is necessary to expose the system of known pulsations to verify the functionality of the monitoring process. This report describes the development of a generator of pressure pulsations to verify the monitoring system. The output should be of harmonic form with a frequency of greater than 160 Hz and 15 mbar in amplitude. To begin with, a few alternatives to a pulsation generator are described. In light of studies of these possibilities the alternative based on a roller bearing is selected. This is considered as one of the easier alternatives to design. An existing generator of pressure pulsations has been analyzed. The calculations from this analysis supported the construction of the new device. The new generator far exceeded the specification regarding frequency, amplitude and harmonics of the pulsations. With a few modifications, such as encapsulation, the pulsation generator will be ready for usage. It could then serve as a mobile device for the inspection of the pulsation monitoring system. Possibly the device could be equipped with a faster and stronger motor. This would permit the device to be used for the calibration of pulsation monitoring sensors.
30

Korslimmat trä som förstärkningsåtgärd i limträbalk vid zoner där pelare möter balk / CLT as a reinforcement measure in glulam beam at zones where pillars meet beam

Stenberg, Fredrik, Hagberg, Carl January 2021 (has links)
Intresset för byggnader med trä som bärande stomme har ökat. Det byggs allt från höga bostadshus till sportarenor där trä är det dominerande materialet. Utvecklingen har gått fort inom träkonstruktion, vilket har lett till att man idag kan använda träregelstomme och skivmaterial för att uppfylla motsvarande säkerhets- och brandkrav som tidigare endast var möjligt vid byggnation med betong och stål. Högre och större byggnader medför också högre laster där tryck vinkelrätt fibrerna är något som behöver beaktas. Detta medför vissa utmaningar vid projektering av rena träkonstruktioner då upplagsareorna blir väldigt stora för att klara de dimensioneringskrav som idag ställs enligt svenska byggregler. Denna problematik grundar sig i att trä som material har olika egenskaper i olika riktningar och att materialet är relativt svagt vid belastning vinkelrätt fiberriktningen. Problematiken blir ofta koncentrerat till zoner där pelare möter balk där balken lätt deformeras. Syftet med examensarbetet är att undersöka om korslimmat trä kan fungera som förstärkningsåtgärd vid upplaget i en limträbalk. För att ta reda på detta trycktestades 25 st provkroppar där de är förstärkta med en, två eller tre lameller av korslimmat trä. Resultatet jämförs sedan mot tryckkraftskapaciteten för en oförstärkt balk. Dimensionerna på provkropparna är 86x315 mm där limträet är av typen GL30C och där hållfasthetsklassen hos de korslimmade lamellerna är C24. Idén är att uppnå ett globalt starkare förband. Vid de experimentella försöken används en hydraulisk press som mäter kraft och förskjutning samt ett beröringsfritt mätsystem som mäter töjningar. Resultaten visar att tryckkraftskapaciteten ökar med ökat antal korslimmade lameller. Jämförelse mellan ett oförstärkt förband och ett förband förstärkt med 3 KL-lameller visar en ökning av tryckkraftskapacitet med 130 % vid en förskjutning på 10 mm. Lastspridningen i materialet är svår att definiera exakt, men det tyder på att någon form av lastspridning sker. Den effektiva arean vid limträet ökar då töjningar uppstår under hela KL-lamellens längd. Slutsatsen är att korslimmat trä som förstärkningsåtgärd kan öka tryckkraftskapaciteten i ett förband. / Interest in buildings with wood as a load-bearing frame has increased. Everything is built from tall residential buildings to sports arenas where wood is the dominant material. The development has been rapid in wood construction, this has led to the fact that today it is possible to use wooden frame and board material to meet the corresponding safety and fire requirements that were previously only possible for construction with concrete and steel. Higher and larger buildings also carry higher loads where pressure perpendicular to the fibers is something that needs to be considered. This entails certain challenges when designing clean wooden structures where the effective areas will be very large in order to meet the dimensioning requirements that are currently set according to Swedish building regulations. This problem is based on the fact that wood as a material has different properties in different directions and that the material is relatively weak when loaded perpendicular to the fiber direction. The problem is often concentrated in zones where pillars meet beams where the beam is easily deformed.  The purpose of this study is to investigate whether cross-laminated timber can function as a reinforcement measure between pillars and beams. To investigate this, 25 glulam timber beams with various modifications were pressure tested and reinforced with one, two or three slats of cross-laminated timber. The result is then compared with the compressive force capacity of an unreinforced beam. The dimensions of the specimens are 86x315 mm where the glulam is of the GL30C type and where the strength class of the cross-glued slats is C24. The idea is to achieve a globally stronger unit. The experimental experiments use a hydraulic press that measures force and displacement and a non-contact measuring system that measures strains. The results show that the compressive force capacity increases with an increased number of cross-laminated timber slats. Comparison between an unreinforced joint and a joint reinforced with 3 KL slats shows an increase in compressive force capacity of 130% at a displacement of 10 mm. The load spreading in the material is difficult to define exactly, but it indicates that some form of load spreading takes place. The effective area at the glulam increases as strains occur during the entire length of the KL slat. The conclusion of the study is that cross-laminated timber as a reinforcing measure can increase the compressive capacity of a joint.

Page generated in 0.0217 seconds