• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 6
  • 1
  • Tagged with
  • 37
  • 12
  • 9
  • 8
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo de compatibilidade entre cafeína, dipirona e citrato de orfenadrina

Alencar, Laianne Carla Batista 26 August 2016 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-04-11T14:02:19Z No. of bitstreams: 1 PDF - Laianne Carla Batista Alencar.pdf: 76493536 bytes, checksum: 81979c4a19d0b51b9825af83908d898c (MD5) / Approved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2018-04-23T20:27:02Z (GMT) No. of bitstreams: 1 PDF - Laianne Carla Batista Alencar.pdf: 76493536 bytes, checksum: 81979c4a19d0b51b9825af83908d898c (MD5) / Made available in DSpace on 2018-04-23T20:27:02Z (GMT). No. of bitstreams: 1 PDF - Laianne Carla Batista Alencar.pdf: 76493536 bytes, checksum: 81979c4a19d0b51b9825af83908d898c (MD5) Previous issue date: 2016-08-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The development of a new pharmaceutical form involves a number of preliminary analyzes, which constitute the pre-formulation study, which will be gathered information about the physical, chemical and mechanical properties of the formulation constituents. Therefore, it is necessary to investigate the compatibility of active pharmaceutical ingredients and excipients of the final product by means of thermoanalytical and non-thermal techniques as possible interactions can alter and compromise the efficacy, safety and quality of the product. Therefore, the primary objective of this study is to assess the compatibility of the active pharmaceutical inputs dipyrone, and caffeine citrate orfenandrina each other and excipients. The differential scanning calorimetry (DSC) was performed in ratios of 2, 5 and 10 ° C / min^-1, coupled with differential thermal analysis (DTA), infrared spectroscopy (FTIR) and x-ray diffraction (XRD). All DSC curves were obtained melting points of the active pharmaceutical ingredients, especi ally the values of the melting point found in the heating rate of 2 ° C / min, which were 237.75 ° C, 222.36 ° C and 140 , 41 ° C for caffeine, dipyrone and orphenadrine citrate, respectively. While, in the cooling curves was not identified any polymorphism. The quaternary DTA curves evaluated aerosil selection at the expense of pregelatinized starch and microcrystalline cellulose 101. From the curves of the binary mixture, those containing dipyrone showed greater mismatch indication, whereas the mixtures of the active pharmaceutical ingredients from themselves were compatible, since the characteristic peaks thereof were identified without changing considerably, its thermal events. In the infrared spectra there is a chemical interaction of carboxymethylcellulose with caffeine, moreover, the spectra containing the binary mixtures dipyrone there was suppression on the free hydroxyl bands glycolate starch, carboxymethylcellulose, starch and croscarmellose sodium, a similar result occurred with the starch glycolate opposite orphenadrine citrate. The XRD patterns did not identify displacement or removal of significant robins to characterize some sort of incompatibility. Through evaluation by different analytical techniques across the various preparations, it was observed that the IFA may be sold simultaneously in view of their physical and chemical compatibility. / O desenvolvimento de uma nova forma farmacêutica envolve um conjunto de análises preliminares, que constituem o estudo de pré-formulação, onde serão reunidas informações a respeito das características físicas, químicas e mecânicas dos constituintes da formulação. Para tanto, faz-se necessário investigar a compatibilidade entre os insumos farmacêuticos ativos e os excipientes do produto final, por meio de técnicas termoanaliticas e não térmicas, visto que possíveis interações podem alterar e comprometer a eficácia, segurança e a qualidade do medicamento. Portanto, o objetivo precípuo desse estudo consiste em avaliar a compatibilidade dos insumos farmacêuticos ativos dipirona, cafeína e citrato de orfenandrina entre si e os excipientes. A calorimetria exploratória diferencial (DSC) foi realizada nas razões de 2, 5 e 10 °C/min^-1, aliada a análise térmica diferencial (DTA), espectroscopia de infravermelho(FTIR) e difração de -1 , aliada a raio X (DRX). Nas curvas de DSC foram obtidos os pontos de fusão dos insumos farmacêuticos ativos, destacando-se os valores do ponto de fusão encontrados na razão de aquecimento de 2 °C/min, que foram de 237,75 ºC, 222,36 ºC e 140,41 ºC para cafeína, dipirona e citrato de orfenadrina, respectivamente. Enquanto que, nas curvas de resfriamento não foi identificado nenhum tipo de polimorfismo. As curvas quaternárias da DTA avaliaram a seleção do aerosil em detrimento do amido pre-gelatinizado e celulose microcristalina 101. A partir das curvas das mistura binárias, as que continham dipirona apresentaram maiores indícios de incompatibilidade, enquanto que, as misturas dos insumos farmacêuticos ativos entre si foram compatíveis, uma vez que os picos característicos dos mesmos foram identificados sem alterar, consideravelmente, seus eventos térmicos. Nos espectros de infravermelho verificou-se interação química da carboximetilcelulose com a cafeína, além disso, nos espectros contendo as misturas binarias de dipirona houve supressão nas bandas de hidroxila livre de amido glicolato, carboximetilcelulose, amido e croscarmelose sódica, resultado semelhante ocorreu com o amido glicolato frente ao citrato de orfenadrina. Os difratogramas não identificaram deslocamentos ou supressão de piscos significantes para caracterizar algum tipo de incompatibilidade. Por meio da avaliação por diferentes técnicas analíticas frente a várias preparações, foi observado que os IFA podem ser comercializados concomitantemente, tendo em vista a sua compatibilidade física e química.
32

Avaliação do efeito citoprotetor do composto homeopático canova® em linhagem celular de rim de macaco verde africano (VERO) exposta ao fármaco dipirona sódica

BONFIM, Laís Teixeira 01 March 2018 (has links)
Submitted by JACIARA CRISTINA ALMEIDA DO AMARAL (jaciaramaral@ufpa.br) on 2018-05-07T17:39:51Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertaçao Bonfim,l.pdf: 1231590 bytes, checksum: 86a9fb61f83eb8bcd872767ed2f2b3f1 (MD5) / Approved for entry into archive by JACIARA CRISTINA ALMEIDA DO AMARAL (jaciaramaral@ufpa.br) on 2018-05-07T17:45:37Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertaçao Bonfim,l.pdf: 1231590 bytes, checksum: 86a9fb61f83eb8bcd872767ed2f2b3f1 (MD5) / Made available in DSpace on 2018-05-07T17:45:37Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertaçao Bonfim,l.pdf: 1231590 bytes, checksum: 86a9fb61f83eb8bcd872767ed2f2b3f1 (MD5) Previous issue date: 2018-03-01 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O paracetamol, a dipirona sódica e o ibuprofeno estão entre os principais medicamentos isentos de prescrição médica disponíveis nas farmácias. Entre estes fármacos, a dipirona sódica tem se destacado na literatura como um dos medicamentos mais utilizados. Apesar de seu amplo uso, nosso grupo de pesquisa tem demostrado que a dipirona sódica apresenta efeitos genotóxicos e citotóxicos. Desta forma, são de grande importância estudos com medicamentos que proporcionem proteção ou que amenizem os eventuais danos causados por esta droga. O composto homeopático Canova® (CA) parece ser um bom candidato para esse fim, uma vez que ameniza os efeitos colaterais de medicamentos a ele associado. Portanto, o presente trabalho teve como objetivo avaliar o possível efeito citoprotetor do CA em linhagem celular de rim de macaco verde africano (VERO) exposta ao fármaco dipirona sódica utilizando os ensaios do cometa, apoptose e imunocitoquímica. Nossos resultados demonstaram através do teste do cometa que a dipirona sódica induziu um aumento no índice de dano (ID) ao DNA da linhagem VERO. No entanto, quando estas células foram co-tratadas com CA nas três concentrações estudadas, observou-se uma redução significativa no ID, o que indica um possível efeito antigenotóxico do CA. Quanto ao ensaio de apoptose e necrose observamos que a dipirona induziu um aumento na percentagem de apoptose tanto em 24 quanto em 48 h. Entretanto, quando este fármaco foi associado ao CA, foi observada uma redução significativa neste efeito nas três concetrações de CA + dipirona. No que diz respeito aos resultados de imunocitoquímica, foi demonstrado um aumento na expressão de caspase 8 e citocromo C quando as células foram expostas à dipirona; em contrapartida, o co-tratamento reduziu significativamente este efeito. Quanto à expressão de caspase 9, observamos que a dipirona induziu um aumento nesta atividade, porém o co-tratamento não apresentou a capacidade de reduzir tal efeito. Desta forma, desmonstrou-se, em nossas condições experimentais, que CA age como citoprotetor conta os danos causados pela dipirona. / Paracetamol, sodium dipyrone and ibuprofen are among the main medicines exempt from medical prescription available in pharmacies in Brazil. Sodium dipyrone is highlighted in the literature as one of the most commonly used drugs. Despite its wide use, our research group demonstrated that sodium dipyrone exerts genotoxic and cytotoxic effects. Therefore, studies with medicines that may provide protection or that ameliorate the possible damages caused by sodium dipyrone are very important. The homeopathic compound Canova® (CA) seems to be a good candidate for such purpose, since in combination with other drugs it seems to soften the side effects of such drugs. Therefore, the present work aims to evaluate the possible cytoprotective effect of CA on African green monkey kidney cell line (VERO) exposed to the drug sodium dipyrone using the comet, micronucleus, apoptosis and immunocytochemistry assays. Results obtained by the comet test showed that sodium dipyrone induces an increase in DNA damage index of the VERO line. However, when such cells were co-treated with CA at the three concentrations studied, a significant reduction in the ID was observed, indicating a possible antigenotoxic effect of CA. We observed in the apoptosis and necrosis assays that dipyrone induced an increase in the percentage of apoptosis in both 24 hours and 48 hours. However when the drug was associated with CA, a significant reduction in this effect was observed in the three concentrations of CA + dipyrone. Results on immunocytochemistry showed an increase in the expression of caspase 8 and cytochrome C when cells were exposed to dipyrone. On the other hand, co-treatment significantly reduced such effect. Expression of caspase 9 was also observed after dipyrone tratament, however, co-treatment did not reduce such effect. Therefore, in our experimental conditions CA acted as a cytoprotect agent against the damages induced by dipyrone.
33

Avaliação in vitro dos efeitos genotóxicos e citotóxicos do fármaco dipirona sódica (Metamizol Sodium) em linhagem de rim de macaco verde africano (VERO)

GOMES, Lorena Monteiro 27 October 2016 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-27T14:08:53Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoInVitro.pdf: 1012726 bytes, checksum: c0d0718db22f5099036b8f129b782f93 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-04-06T14:17:32Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoInVitro.pdf: 1012726 bytes, checksum: c0d0718db22f5099036b8f129b782f93 (MD5) / Made available in DSpace on 2017-04-06T14:17:32Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AvaliacaoInVitro.pdf: 1012726 bytes, checksum: c0d0718db22f5099036b8f129b782f93 (MD5) Previous issue date: 2016-10-27 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A dipirona sódica ou metamizol sodium, pertencente à família das pirazolonas, é um dos compostos anti-inflamatórios não esteroidais (AINEs) mais utilizados, inclusive no Brasil, principalmente devido a sua comercialização ser de baixo custo financeiro. Porém, em determinados países a venda deste medicamento é proibida devido a relatos de casos graves de agranulocitose em decorrência do seu uso. Apesar de sua ampla utilização, estudos demonstrando efeitos genotóxicos e citotóxicos da dipirona em células de mamíferos são escassos. Portanto, o presente trabalho pretende avaliar a viabilidade celular, os efeitos genotóxicos, os efeitos citotóxicos (indução de apoptose e necrose) e a produção de espécies reativas de oxigênio (ROS) em linhagem VERO (linhagem renal de macaco verde africano) expostas a dipirona. Nossos resultados demonstraram uma redução significativa na viabilidade das células expostas a dipirona pelo ensaio MTT. Um aumento significativo no índice de dano avaliado pelo teste do cometa também foi observado, indicando o potencial genotóxico da droga. No que diz respeito aos efeitos citotóxicos da dipirona, observou-se um aumento significativo no número de células apoptóticas utilizando-se corantes fluorescentes tanto em 24 quanto em 48 h de tratamento com a droga. Nossos resultados também mostraram que não houve indução significativa na geração de ROS pela droga por meio da técnica do DCFH-DA. Desta forma, demonstrou-se em nosso trabalho, que a dipirona é uma droga genotóxica e citotóxica em linhagem VERO, nas condições avaliadas. / The dipyrone or metamizole belongs to the family of the pyrazolones. It is one of the nonsteroidal anti-inflammatory compounds (NSAIs) most used, Brazil included, mainly due to its low financial cost. However, in some countries the sale of dipyrone is prohibited due to reported severe cases of agranulocytosis as a result of its use. Despite its high usage, studies showing genotoxic and cytotoxic effects of dipyrone in mammalian cells are scarce. Therefore, in the present study we will assess cell viability, genotoxic effects, cytotoxic effects (by apoptosis and necrosis induction) and the induction of reactive oxygen species (ROS) in VERO cells (a cell line obtained from red kidney of green monkey) exposed to dipyrone. Our results showed a significant reduction in viability of cells exposed to dipyrone by the MTT assay. A significant increase in damage index evaluated by comet assay was also observed, which indicate its genotoxic effects. In which concerns the cytotoxic effects of dipyrone, we observed a significant increase in the number of apoptotic cells using fluorescent dyes after 24h and 48 h of treatment with the drug. Ours results also showed that there was no significant difference in the induction of ROS generation after treatment of the cells with the drug assessed by the DCFH-DA technique. Thus, our work showed that dipyrone is both a genotoxic and cytotoxic drug to VERO cells in the assessed conditions.
34

Um fotômetro LED-NIR duplo feixe microcontrolado e portátil para análise screening e quantitativa de medicamentos injetáveis de forma não invasiva / A micro-processor controlled and portable dual-beam LED-NIR photometer for noninvasive quantitative and screen analyses of injectable drugs

Sanches, Fatima Aparecida Castriani 27 September 2013 (has links)
Made available in DSpace on 2015-05-14T13:21:31Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 4300715 bytes, checksum: 6618808ff4fc3b330190a5a4b7fe14f3 (MD5) Previous issue date: 2013-09-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this work, a portable LED - NIR double beam micro-processor controlled photometer for non-destructive/non-invasive screening and quantitative analysis of injectable medicines was developed to assess conformity with values established by the Brazilian Pharmacopoeia. The product analyzed was injectable dipyrone (1g/2 mL) sold in amber colored vials of 1.1 cm outer diameter, and 6 cm in height. Initially, spectroscopic studies were carried out employing a commercial spectrophotometer to assess the best NIR spectrum regions that might be used. The instrument developed used two twin LEDs with NIR radiation emissions rated at 1050 ± 50 nm. Two InGaAs photodiodes (also identical), and a PIC18F455 microcontroller were used as well. The output of the instrument used a PIC microcontroller coupled to a 20x2 liquid crystal display which communicated with a PC by USB 2.0 for communication. The instrument evaluated commercial dipyrone injection samples using absorbance measurements made directly from ampoules of the injectable medicines. The photometer was calibrated with standard solutions of dipyrone, and its performance was evaluated by an analysis of 620 of the commercial dipyrone injection samples, where 320 were expired. The instrument had a high success rate for screening analysis (91%). For quantitative determination of the active dipyrone, a linear response was obtained [R2 = 0.9964, A = 0.0068 + 0.0043 C (% w/v)] in the concentration range of 5 to 60% m/v. We also obtained a low relative error of 0.40%, and good accuracy in the analyses with a relative standard deviation of 2.13%. / Neste trabalho foi desenvolvido um fotômetro LED-NIR duplo feixe microcontrolado e portátil para análise screening e quantitativa de medicamentos injetáveis de forma não destrutiva/não invasiva, visando investigar a conformidade desses com os valores estabelecidos na Farmacopéia Brasileira. O medicamento analisado foi a dipirona sódica injetável 1g/2mL, comercializados em ampolas de coloração âmbar. Foram realizados inicialmente estudos espectroscópicos empregando um espectrofotômetro comercial para avaliar quais as melhores regiões do espectro NIR que poderiam ser empregadas para a determinação da espécie de interesse. O instrumento desenvolvido utiliza dois LEDs-NIR com emissão de radiação nominal em 1050 ± 50 nm gêmeos (de mesmas especificações técnicas), dois fotodiodos de InGaAs também idênticos e um microcontrolador PIC18F455. Como dispositivos de saída do instrumento foram empregados o microcontrolador PIC acoplado a um display de cristal líquido 20x2, o qual também se comunica com um microcomputador portátil por comunicação USB 2.0. O instrumento foi avaliado com amostras comerciais de dipirona sódica injetável por medidas de absorbância efetuadas diretamente nas ampolas dos medicamentos injetáveis. O fotômetro foi calibrado com soluções padrão de dipirona e seu desempenho foi avaliado na análise de 620 amostras comerciais de dipirona injetável, das quais 320 apresentavam prazo de validade expirado. O instrumento obteve elevado índice de acerto para a análise screening (91%). Para determinação quantitativa do princípio ativo dipirona, uma resposta linear foi obtida [R2 = 0,9964, A = 0,0068 + 0,0043 C (% m/v)] na faixa de concentração de: 5 a 60 % m/v. Também foi obtido um baixo erro relativo conjunto (0,40 %) e boa precisão nas análises (desvio padrão relativo conjunto = 2,13%).
35

Involviment of cannabinoids CB1, CB2 recepotrs and KAPT channel in the anti-hiperalgesic effect mediated by dipyrone and its bioactives metabolites = Envolvimento dos receptores canabinóides CB-1 e CB-2 e canais KATP do tecido periférico na analgesia mediada pela dipirona e seus metabólitos bioativos / Envolvimento dos receptores canabinóides CB-1 e CB-2 e canais KATP do tecido periférico na analgesia mediada pela dipirona e seus metabólitos bioativos

Dos Santos, Gilson Gonçalves, 1986- 26 August 2018 (has links)
Orientador: Carlos Amilcar Parada / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-26T11:05:11Z (GMT). No. of bitstreams: 1 DosSantos_GilsonGoncalves_M.pdf: 2757194 bytes, checksum: 3b5bda3ca0fc7912d13b42ba51399734 (MD5) Previous issue date: 2014 / Resumo: A dipirona (metamizol) é um pró-fármaco analgésico utilizado no controle da dor moderada, sendo metabolizada em dois metabolitos bioativos: 4-metil-aminoantipirina (4-MAA) e 4-aminoantipirina (4-AA). O objetivo deste estudo foi investigar a participação de receptores canabinóides periféricos, CB1, CB2 e canais de KATP sobre o efeito anti-hiperalgésico da dipirona, 4-MAA ou 4- AA. Para indução de hiperalgesia, PGE2 (100 ng/pata ) foi administrada localmente na pata traseira de ratos Wistar machos, e o limiar hiperalgésico mecânico foi quantificado por Von- Frey eletrônico, antes e três horas após a injeção. Dipirona, 4-MAA ou 4-AA foram administrados 30 minutos antes do Von Frey. Os antagonistas seletivos do receptor CB1 (AM251), CB2 (AM630) e glibenclamida, um bloqueador KATP (80 ug) ou ODQ um inibidor de cGMP (32 ?g) foram administrados 30 minutos antes da Dipirona, 4-MAA ou 4 -AA. O ODN-antisense para reduzir a expressão do receptor CB1 (30 ?g) foi administrado por via intratecal, uma vez por dia durante quatro dias consecutivos. A hiperalgesia mecânica induzida pela PGE2 foi reduzida pela dipirona, 4-MAA, e 4-AA de maneira dose-dependente. AM251 ou ODN-antisense contra o receptor neuronal CB1, mas não AM630, reduziu o efeito anti-hiperalgésico mediado por 4-AA, mas não da dipirona ou 4-MAA. Por outro lado, o efeito anti-hiperalgésico da dipirona, ou 4-MAA foi revertido por glibenclamida ou ODQ. Os resultados sugerem que a ativação de receptores neuronal CB1, mas não do receptor CB2, no tecido periférico esteja envolvido no efeito anti-hiperalgésico do metabólito 4-AA. Além disso, a dipirona e 4-MAA possui um efeito anti-hiperalgesico dependente de cGMP e consequente abertura KATP / Abstract: Dipyrone (metamizole) is an analgesic pro-drug used to control moderate pain. It is metabolized in two bioactive metabolites: 4-methylaminoantipyrine (4-MAA) and 4-aminoantipyrine (4-AA). The aim of this study was to investigate the participation of peripheral CB1 and CB2 cannabinoid receptors activation on the anti-hyperalgesic effect of Dypirone, 4-MAA or 4-AA. For induction of hyperalgesia, PGE2 (100 ng) was locally administrated in hindpaw of male Wistar rats, and the mechanical nociceptive threshold was quantified by electronic von-Frey, before and 3 hours after its injection. Dypirone, 4-MAA or 4-AA was administrated 30 minutes before the von-Frey test. The selective CB1 receptor antagonist AM251, CB2 receptor antagonist AM630, cGMP inhibitor ODQ (32 ?g) or KATP blocker glibenclamide (80 ?g) was administrated 30 minutes before Dypirone, 4-MAA or 4-AA. The antisense-ODN against CB1 receptor expression (30 ?g) was intrathecally administrated once a day during four consecutive days. PGE2-induced mechanical hyperalgesia was inhibited by dypirone, 4-MAA, and 4-AA in a dose-response manner. AM251 or ODN anti-sense against neuronal CB1 receptor, but not AM630, reversed the antihyperalgesic effect mediated by 4-AA, but not by dypirone or 4-MAA. On the other hand, the anti-hyperalgesic effect of dypirone or 4-MAA was reversed by Glibenclamide or ODQ. These results suggest that the activation of neuronal CB1, but not CB2 receptor, in the peripheral tissue is involved in the anti-hyperalgesic effect of 4-aminoantipyrine. In addition, 4- methylaminontipyrine mediates anti-hyperalgesic effect by the cGMP activation and the KATP opening / Mestrado / Fisiologia / Mestre em Biologia Funcional e Molecular
36

Utilização de eletrodos de Cu e Au em eletroanalítica: detecção amperométrica de etanol em ar exalado e outras aplicações / Utilization of gold and copper electrodes in electroanalysis: amperometric detection of ethanol in breath and other applications

Paixão, Thiago Regis Longo Cesar da 12 March 2004 (has links)
A potencialidade do eletrodo de cobre em meio alcalino foi demonstrada para o determinação de etanol a +0,6 V vs Ag/AgCl. A participação de espécies solúveis de Cu(III) no processo eletrocatalítico envolvendo a oxidação do etanol foi demonstrada por experimentos utilizando eletrodo disco-anel. A influência do potencial de pré-tratamento no sinal anódico foi investigada e correlacionada com a morfologia dos filmes formados na superfície do eletrodo por EDS (Energy Dispersive X-Ray Spectroscopy), indicando que as espécies de Cu(III) são originadas a partir da oxidação da camada de CuO. As medidas de etanol foram realizadas por amperometria em 0,6 V (vs Ag/AgCl). A repetibilidade das medidas utilizando padrão aquoso de etanol 0,05 % (v/v) foi de 3 % (v/v) e os limites de detecção e quantificação foram de 0,005 % (v/v) e 0,01 % (v/v), respectivamente. Nas condições experimentais otimizadas, o sensor amperométrico foi utilizado para o monitoramento da concentração de etanol no ar exalado (BrAC), que foi convenientemente coletado em um balão de borracha (V = 3 L) e introduzido em uma solução de NaOH 1 mol L-1 (V = 10 mL). O sensor apresentou uma faixa linear para concentrações de etanol em ar exalado na faixa de 0,26 – 130 mg L-1, operando de acordo com os parâmetros analíticos especificados na Legislação Brasileira para a quantificação de etanol no ar exalado em condutores de veículos automotores. A constante de eliminação de etanol do corpo humano também foi investigada e os resultados concordaram com os valores da literatura. Empregando-se eletrodos de Cu e Au foram também desenvolvidas outras metodologias para a quantificação de dipirona, glicose e ácido ascórbico e sistemas em fluxo. Estudos sobre o desenvolvimento e propriedades de um sistema gerador-coletor foram realizados e o dispositivo foi utilizado em titulações de substâncias redutoras com iodo gerado eletroquimicamente. / A copper disc working electrode in alkaline solutions was demonstrated to act as a suitable amperometric sensor for ethanol determination at +0.6 V vs Ag/AgCl. The participation of free-soluble Cu(III) species in the electrocatalytic process involving the anodic oxidation of ethanol has been demonstrated by rotating ring-disc electrode voltammetry. The influence of the pretreatment potential on the anodic signal was investigated and a correlation with the morphology of the electrode surface characterized by Energy Dispersive X-Ray Spectroscopy (EDS) indicated that the Cu(III) species is originated from the oxidation of a CuO layer. Ethanol measurements were performed in the amperometric mode at 0.6 V (vs Ag/AgCl). The repeatability of the measurements for a 0.05 % aqueous ethanol solution was estimated as 3 %, and the detection and quantification limits were determined as 0.005 % and 0.01 %, respectively. At the optimum experimental conditions, the amperometric sensor was used to monitor the concentration of ethanol in breath (BrAC), which was conveniently collected in a rubber air balloon (volume = 3 L) and introduced in a 1 mol L-1 NaOH working solution (volume = 10 mL). The sensor can measure a person\'s breath ethanol over the concentration range 0.26 - 130 mg L-1 by operating it according to an established protocol, of which the analytical parameters are specified by the Brazilian Legislation for BrAC measurements in drivers. The rate of ethanol degradation in the body was followed, and the results agree with predictions in the literature. Methodologies for the determination of dipyrone, glucose and ascorbic acid were also developed by using Cu and Au electrodes. Features of a dual-band electrochemical cell were investigated towards the development of a generator-collector system, which was employed in titrations with electrogenerated iodine.
37

Utilização de eletrodos de Cu e Au em eletroanalítica: detecção amperométrica de etanol em ar exalado e outras aplicações / Utilization of gold and copper electrodes in electroanalysis: amperometric detection of ethanol in breath and other applications

Thiago Regis Longo Cesar da Paixão 12 March 2004 (has links)
A potencialidade do eletrodo de cobre em meio alcalino foi demonstrada para o determinação de etanol a +0,6 V vs Ag/AgCl. A participação de espécies solúveis de Cu(III) no processo eletrocatalítico envolvendo a oxidação do etanol foi demonstrada por experimentos utilizando eletrodo disco-anel. A influência do potencial de pré-tratamento no sinal anódico foi investigada e correlacionada com a morfologia dos filmes formados na superfície do eletrodo por EDS (Energy Dispersive X-Ray Spectroscopy), indicando que as espécies de Cu(III) são originadas a partir da oxidação da camada de CuO. As medidas de etanol foram realizadas por amperometria em 0,6 V (vs Ag/AgCl). A repetibilidade das medidas utilizando padrão aquoso de etanol 0,05 % (v/v) foi de 3 % (v/v) e os limites de detecção e quantificação foram de 0,005 % (v/v) e 0,01 % (v/v), respectivamente. Nas condições experimentais otimizadas, o sensor amperométrico foi utilizado para o monitoramento da concentração de etanol no ar exalado (BrAC), que foi convenientemente coletado em um balão de borracha (V = 3 L) e introduzido em uma solução de NaOH 1 mol L-1 (V = 10 mL). O sensor apresentou uma faixa linear para concentrações de etanol em ar exalado na faixa de 0,26 – 130 mg L-1, operando de acordo com os parâmetros analíticos especificados na Legislação Brasileira para a quantificação de etanol no ar exalado em condutores de veículos automotores. A constante de eliminação de etanol do corpo humano também foi investigada e os resultados concordaram com os valores da literatura. Empregando-se eletrodos de Cu e Au foram também desenvolvidas outras metodologias para a quantificação de dipirona, glicose e ácido ascórbico e sistemas em fluxo. Estudos sobre o desenvolvimento e propriedades de um sistema gerador-coletor foram realizados e o dispositivo foi utilizado em titulações de substâncias redutoras com iodo gerado eletroquimicamente. / A copper disc working electrode in alkaline solutions was demonstrated to act as a suitable amperometric sensor for ethanol determination at +0.6 V vs Ag/AgCl. The participation of free-soluble Cu(III) species in the electrocatalytic process involving the anodic oxidation of ethanol has been demonstrated by rotating ring-disc electrode voltammetry. The influence of the pretreatment potential on the anodic signal was investigated and a correlation with the morphology of the electrode surface characterized by Energy Dispersive X-Ray Spectroscopy (EDS) indicated that the Cu(III) species is originated from the oxidation of a CuO layer. Ethanol measurements were performed in the amperometric mode at 0.6 V (vs Ag/AgCl). The repeatability of the measurements for a 0.05 % aqueous ethanol solution was estimated as 3 %, and the detection and quantification limits were determined as 0.005 % and 0.01 %, respectively. At the optimum experimental conditions, the amperometric sensor was used to monitor the concentration of ethanol in breath (BrAC), which was conveniently collected in a rubber air balloon (volume = 3 L) and introduced in a 1 mol L-1 NaOH working solution (volume = 10 mL). The sensor can measure a person\'s breath ethanol over the concentration range 0.26 - 130 mg L-1 by operating it according to an established protocol, of which the analytical parameters are specified by the Brazilian Legislation for BrAC measurements in drivers. The rate of ethanol degradation in the body was followed, and the results agree with predictions in the literature. Methodologies for the determination of dipyrone, glucose and ascorbic acid were also developed by using Cu and Au electrodes. Features of a dual-band electrochemical cell were investigated towards the development of a generator-collector system, which was employed in titrations with electrogenerated iodine.

Page generated in 0.0598 seconds