• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 95
  • 57
  • 18
  • 8
  • 7
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 229
  • 87
  • 63
  • 62
  • 49
  • 44
  • 39
  • 38
  • 38
  • 25
  • 24
  • 24
  • 22
  • 21
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Comparação dos aspectos morfológicos e químicos de esmalte e dentina de dentes decíduos e permanentes / Morphological and chemical aspects comparison between enamel and dentin of permanent and deciduous teeth

Maria Angélica Hueb de Menezes Oliveira 08 July 2009 (has links)
O objetivo deste estudo in vitro foi avaliar e comparar a microestrutura e a composição mineral do esmalte e da dentina de dentes decíduos e permanentes. Terceiros molares hígidos e segundos molares decíduos foram selecionados e distribuídos aleatoriamente em grupos, de acordo com o método de análise dos substratos utilizado: Microscopia Eletrônica de Varredura (MEV), Espectroscopia de Energia Dispersiva de Raio X (EDX), Difração de Raio X (DRX) e Microscopia Óptica (MO). Foi realizada comparação qualitativa e quantitativa da estrutura dental. As medidas de densidade numérica e diâmetro dos prismas de esmalte/túbulos dentinários e, de espessura do esmalte, dentina e dentina peritubular foram realizadas por meio de fotomicrografias obtidas pela MEV. Os resultados obtidos por meio da SEM foram analisados estatisticamente pelo teste não-paramétrico de Kruskal-Wallis. A quantidade relativa de íons cálcio (Ca) e fósforo (P) foram determinadas por meio de EDX e as fases químicas presentes em ambos os substratos, por análise de DRX. O valor das medidas de espessura observado para o esmalte e dentina dos dentes decíduos foi de 1.14 mm e 3.02 mm, respectivamente. Para os dentes permanentes, obtiveram-se valores de 2.58 mm para o esmalte e 5.95 mm para a dentina. Com relação ao diâmetro da cabeça dos prismas de esmalte, os resultados foram estatisticamente semelhantes para os dentes decíduos e permanentes, demonstrando uma ligeira diminuição do diâmetro da superfície externa para a região próxima a junção amelodentinária (JAD). A densidade numérica dos prismas foi maior nos dentes decíduos, principalmente próximo à JAD, sendo estatisticamente diferente dos valores observados nos dentes permanentes, independente da região analisada. Na análise do diâmetro e densidade numérica dos túbulos dentinários verificou-se semelhança estatística entre os dentes decíduos e permanentes, havendo aumento gradativo do número de túbulos a partir da JAD em direção a região próxima a polpa. A espessura da dentina peritubular, na região próxima a JAD e central foi, respectivamente, 0.91 e 0.59 mm nos dentes decíduos 1.16 e 0.98 mm nos dentes permanentes. A porcentagem de Ca e P foi maior nos dentes permanentes. Observou-se ainda, que a quantidade de colágeno nos dentes decíduos foi aparentemente menor quando analisados por meio da MO. De acordo com os resultados obtidos neste estudo, pode-se concluir que, de maneira geral, os dentes decíduos apresentam menor porcentagem de Ca e P, menor espessura de esmalte e dentina, maior densidade numérica de prismas e dentina peritubular mais delgada quando comparada aos dentes permanentes. / This study evaluated in vitro the microstructure and mineral composition of dental enamel and dentin comparing the permanent teeth with the deciduous teeth. Sound third molars and second primary molars were selected and randomly assigned to the following groups, according to the analysis methods of the substrates performed: Scanning Electron Microscopy (SEM), X-Ray diffraction (XRD), Energy dispersive X-ray spectrometer (EDS) and Optical Microscopy (OP). A qualitative and quantitative comparison of the dental structure was done. The measurements of the number and diameter of prisms/tubules, thickness of enamel, dentin and peritubular dentin were done in SEM photomicrographs. The microscopic findings were analyzed statistically by a non-parametric test (Kruskal- Wallis). The relative amounts of calcium (Ca) and phosphorus (P) were determined by EDS investigation. Phase present in both types of teeth were observed by the XRD analysis. The mean thickness measurements observed in the deciduous teeth enamel and dentin was, respectively, 1.14 mm and 3.02 mm and in the permanent teeth, 2.58 mm and 5.95 mm. The mean rod head diameter in deciduous teeth was statistically similar to that of permanent teeth enamel, and a slightly decrease from the outer enamel surface to the region next to the enameldentine junction was assessed. The numerical density of enamel rods was higher in the deciduous teeth, mainly near EDJ, that showed statistically significant difference. The mean tubules number and diameter in deciduous teeth were statistically similar to that of permanent teeth, and this numerical density increased from the EDJ to the region near the pulp. The mean thickness measurements of peritubular dentin observed in the regions near EDJ and central were, respectively, 0.91 and 0.59 mm for the primary teeth / 1.16 and 0.98 mm for the permanent teeth. The percentage of Ca and P was higher in the permanent teeth. The collagen level was apparently lower in deciduous teeth when analyzed by OP. The primary teeth structure showed a lower level of Ca and P and a thinner enamel and dentin thickness. The deciduous enamel presented higher numerical density of rods. The peritubular dentin was thicker in the permanent teeth.
172

Caracterização e composição química do material particulado grosso (MP10) no centro da cidade de São Carlos (SP)

Alexandrina, Eduardo Carlos 27 March 2015 (has links)
Submitted by Bruna Rodrigues (bruna92rodrigues@yahoo.com.br) on 2016-09-15T20:31:27Z No. of bitstreams: 1 DissECA.pdf: 4704364 bytes, checksum: 1909457a146bdb29a74ad65130ca2bd9 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-16T19:58:59Z (GMT) No. of bitstreams: 1 DissECA.pdf: 4704364 bytes, checksum: 1909457a146bdb29a74ad65130ca2bd9 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-16T19:59:07Z (GMT) No. of bitstreams: 1 DissECA.pdf: 4704364 bytes, checksum: 1909457a146bdb29a74ad65130ca2bd9 (MD5) / Made available in DSpace on 2016-09-16T19:59:13Z (GMT). No. of bitstreams: 1 DissECA.pdf: 4704364 bytes, checksum: 1909457a146bdb29a74ad65130ca2bd9 (MD5) Previous issue date: 2015-03-27 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coarse particulate matter with aerodynamic diameter smaller than 10μm (PM10) have long been considered as air pollutants associated with health issues. They penetrate into the upper respiratory tract, causing respiratory problems such as worsening of asthma. The aim of this study was to determine and quantify the distribution of chemical elements in the PM10 particulate matter present in the atmosphere of the city of Sao Carlos (Sao Paulo). Samples were collected daily for a period of 23h and 30 minutes, from April 16, 2014 to April 16, 2015. A high-volume sampler (AGV-PM10) with micro quartz and fiber glass filters were used. The filters were subjected to gravimetric analysis to obtain the mass of PM10 and were then analyzed by energy dispersive X-ray fluorescence and Laser Induced Breakdown Spectroscopy to identify and quantify the chemical composition of the samples. The highest average concentration during twelve-month period was 70.41μg/m³ (August, 2014) and the smallest was 22.59μg/m³ (January, 2015). The annual arithmetic average found for the twelve months period was 42.71μg/m³. If compared with annual arithmetic average limit of 40μg/m³, established by CETESB, the value is slightly above and below 50 μg/m³ (CONAMA). If we consider the limit established by the World Health Organization (WHO), which is 20μg/m³, this value is much higher than recommended. The chemicals elements found were characteristic of urban areas / O material particulado, cujo diâmetro aerodinâmico é menor do que 10μm vem sendo considerado como poluente atmosférico muito associado a questões de saúde, uma vez que são os que penetram em vias respiratórias, agravando problemas como o da asma, por exemplo. O objetivo deste trabalho foi avaliar os níveis de concentração de material particulado (MP10) e determinar a distribuição dos elementos químicos deste material particulado presente no ar atmosférico do centro da cidade de São Carlos (São Paulo). As amostras foram coletadas diariamente, por um período de 23h e 30 minutos, entre 16 de abril de 2014 a 16 de abril de 2015. Foi utilizado um amostrador de grandes volumes (AGV-MP10), submetendo os filtros, de fibra de vidro e de micro quartzo, à análise gravimétrica para obtenção de massa de MP10, Fluorescência de Raios-X de Energia Dispersiva de (EDX) e a Espectroscopia de ruptura induzida por laser (LIBS) para identificação e quantificação da composição química elementar das amostras. A maior concentração média do período de doze meses amostrado foi de 70,41μg/m³ em agosto/2014 e a menor de 22,59μg/m³ em janeiro/2015. A média aritmética anual encontrada para o período de doze meses foi de 42,71μg/m³. Se comparada com a média aritmética anual do limite estabelecido pela CETESB, de 40μg/m³, o valor está um pouco acima e um pouco abaixo de 50 μg/m³(CONAMA). Se for considerado o limite estabelecido pela Organização Mundial da Saúde (OMS), que é de 20 μg/m³, este valor encontra-se muito acima do recomendado. Os elementos químicos encontrados são característicos de áreas urbanas e apresentam resultados semelhantes a estudos anteriores na cidade.
173

Problema de Cauchy para un Sistema de Tipo Benjamin-Bona-Mahony / Problema de Cauchy para un Sistema de Tipo Benjamin-Bona-Mahony

Montealegre Scott, Juan 25 September 2017 (has links)
It is proved that the initial value problem for a system of two Benjamin-Bona-Mahony equations coupled through both dispersive and nonlinear terms is locally and globally well posed in the Soboloev spaces Hs ×Hs with s ≥ 0 / Dado el problema de valor inicial para un sistema de dos ecuaciones de Benjamin-Bona-Mahony (BBM) acopladas a través de los términos dispersivos y no lineales, se demuestra que está bien colocado localmente y globalmente en los espacios Hs × Hs con s≥0.
174

Determinação da concentração de elementos químicos potencialmente tóxicos em aerossóis presentes no interior de uma pequena indústria de fundição de metais, utilizando amostrador temporal e a técnica de fluorescência de raios X / Toxic inorganic elements content in suspended particulate matter inside a small foundry plant by streaker sampler and energy dispersive X-ray fluorescence technique

Paulo Rogério Massoni 09 March 2009 (has links)
Este trabalho foi desenvolvido objetivando a determinação e a avaliação dos perfis temporais da concentração de alguns elementos químicos potencialmente tóxicos presentes no material particulado em suspensão (MPS) no interior de uma pequena indústria de fundição de metais bronze, ferro e alumínio que, em concentrações elevadas, podem acarretar sérios riscos à saúde do trabalhador. Para isso foi utilizado um amostrador temporal de MPS, que coleta amostras de aerossóis em intervalo de tempo pré-programados, separando-os por tamanho: (a) fração fina ou respirável (partículas com diâmetro aerodinâmico menor que 2,5 m, MP2,5) e (b) fração grossa ou inalável (entre 2,5 a 10 m, MP10-2,5), durante todo o período do processo de fundição (da fusão à moldagem). As amostras coletadas, na forma de faixas (strips) sobre um filtro (fração fina) e sobre um impactador (fração grossa), foram analisadas pela técnica de fluorescência de raios X por dispersão de energia (EDXRF), utilizando na excitação um tubo de raios X com alvo de Mo e e na detecção dos raios X característicos um detector semicondutor de Si(Li) acoplado a um analisador de pulsos multicanal, interpretando-se posteriormente os espectros de raios X obtidos pelo aplicativo AXIL. Para algumas amostras também foi feita uma análise com microscópio eletrônico de varredura (SEM/EDS) para se conhecer a morfologia dos particulados. Deste modo foi possível determinar a concentração de elementos químicos potencialmente tóxicos presentes em um ambiente de uma pequena indústria de fundição de metais, mostrando que o momento mais crítico dessa atividade foi o da moldagem e também determinar a forma do MPS. Na fundição do bronze e ferro, as concentrações dos elementos Cr, Mn, Ni e Pb, principalmente na fração fina no momento de moldagem, mostraram-se muito superior aos limites recomendados pelas agências brasileira e norte-americana. Apesar de não haver limites recomendados para o elemento Zn, foi verificada uma alta concentração principalmente na concentração na fração fina, o mesmo sucedendo para o Cu. Com respeito a fundição de alumínio, foi observado altas concentrações principalmente de Zn e Cu, somente na fração fina, não ocorrendo na fração grossa. Pelos resultados obtidos pode-se concluir que os trabalhadores estão sujeitos a condições insalubres de trabalho nesse tipo de ambiente, aconselhando-se o uso permanente de equipamentos adequados de proteção visando de preferência a fração fina, assim como um monitoramento constante desses elementos químicos durante todas as etapas do processo de fundição, principalmente na de moldagem / The aim of this work was to evaluate the chemical concentration of some potentially toxic inorganic chemical elements and the time profiles in fine (PM2.5, particles up to 2.5 m) and coarse (PM2.5-10, particles from 2.5 to 10 m) suspended particulate matter (SPM) inside a small foundry plant - bronze, iron and aluminium -, in which at high concentrations turns a healthy concern. For these purpose, a rotating streaker airparticulate sampler for sampling during all day foundry activity was utilized. Fine SPM was collected on a filter and coarse SPM in turn by an impactor. The collected samples were analyzed by energy dispersive X-ray fluorescence (EDXRF) technique employing a Mo target tube in the excitation, and the detection was carried out through Si(Li) semiconductor detector coupled to multichannel analyser, deconvolutting the X-ray spectra with AXIL software help. It was also carried out particulated morphological analysis by scanning electron microscopy with energy dispersive X-ray spectrometer coupled (SEM/EDS). In this manner, the inorganic chemicals content were determined in the small foundry allowing concluding that the moulding step is the critical one taking into account the amount of pollutant released. During bronze and iron melting, the Cr, Mn, Ni and Pb contents in SPM were higher than allowed values by Brazilian and United States legislations. It was also verified a high Zn and Cu content, mainly in the fine suspended particulate matter, although these elements are not contemplated by national nor international laws. Thus, due to this unhealthy environmental working conditions inside the small foundry plant,a proper individual protection equipment is mandatory mainly for fine suspended particulate matter, and a constant air pollutant monitoring in foundry plants is demanded, mainly during the moulding step
175

Avaliação de microtécnicas de extração para análise de lamotrigina em plasma de pacientes epilépticos por eletroforese capilar / Evaluation of microextraction techniques to analysis of lamotrigine in plasma samples of epileptic patients by capillary electrophoresis

Luiza Saldanha Ribeiro Barros 23 March 2016 (has links)
A lamotrigina (LTG) é um fármaco pertencente à classe das feniltriazinas utilizado no tratamento de crises epilépticas generalizadas e focais e no tratamento adjunto da epilepsia refratária. Devido à alta variabilidade interindividual, às interações medicamentosas e aos efeitos adversos apresentados durante a administração da LTG, a monitorização terapêutica nos pacientes que fazem uso deste fármaco é necessária para ajuste de dose individual e evitar os efeitos adversos. Assim, o objetivo deste trabalho foi a avaliação de duas técnicas de microextração: a microextração em fase líquida com fibras ocas (HF-LPME) e a microextração líquido-líquido dispersiva (DLLME) para análise da lamotrigina em amostras de plasma de pacientes epilépticos. Primeiramente foram definidas as condições eletroforéticas: foi utilizado um capilar de sílica fundida de 75 ?m de diâmetro interno e 50 cm de comprimento efetivo. O eletrólito de corrida (BGE) foi composto por ácido 2-morfolinoetanosulfônico (MES), na concentração de 130 mmol L-1 e pH 5,0. As análises foram realizadas à temperatura de 20°C e tensão de 15 kV. A amostra foi injetada hidrodinamicamente (0,5 psi por 10 s) e a detecção foi feita em 214 nm. Nestas condições a LTG e o padrão interno (PI), lidocaína, puderam ser analisados em menos de 7 minutos. A HF-LPME foi avaliada no modo de 3 fases, usando 500 ?L de plasma e 3,5 mL de solução fosfato de sódio 50 mmol L-1 pH 9,0 como fase doadora. O solvente utilizado para impregnar a fibra foi o 1-octanol. Como fase aceptora foram utilizados 60 ?L de solução de ácido clorídrico pH 4,0. Para avaliação da DLLME, foi necessária uma etapa de pré-tratamento da amostra (500 ?L de plasma) com 1 mL de acetonitrila. Após isto, 1,3 mL do sobrenadante foram adicionados a 4 mL de solução fosfato de sódio 50 mmol L-1 pH 9,0 e 120 ?L de clorofórmio (solvente extrator) foram injetados nesta amostra aquosa e 165 ?L de fase sedimentada foram recuperados. As características de desempenho analítico para ambos os métodos foram avaliadas, sendo obtida linearidade na faixa de concentração plasmática de 1-20 ?g/mL e limite inferior de quantificação (LIQ) de 1 ?g mL-1. Os ensaios de precisão e exatidão apresentaram valores de acordo com os guias oficiais. Além disso, os métodos foram seletivos, não apresentaram efeito residual e as amostras foram estáveis. Os valores de recuperação foram de 54,3 e 23% para HF-LPME e DLLME, respectivamente. Os métodos validados foram aplicados com sucesso em amostras de plasma de pacientes epilépticos em tratamento com a LTG. Além disso, as duas técnicas foram comparadas e a HF-LPME apresentou vantagens em relação à DLLME, mostrando ser uma técnica promissora para análise de matrizes complexas, com reduzido consumo de solvente orgânico e possibilidade de automação. / Lamotrigine (LTG) is an antiepileptic drug, which belongs to the class of phenyltriazine that can be used in the treatment of new-onset and refractory epilepsy. Due to its high interindividual variability, drug interactions and the adverse effects presented during the LTG administration, therapeutic drug monitoring is very important to dose adjustment and to avoid toxicity effects. Thus, the goal of this study was to develop and validate two microextraction techniques: the hollow fiber liquid-phase microextraction (HF-LPME) and the dispersive liquid-liquid microextraction (DLLME) to analyze LTG in plasma samples of epileptic patients. First of all, the eletroforetic conditions were optimized. A fused-silica uncoated capillary with 75 ?m internal diameter, and 50 cm effective length was used. The 2-(N-morpholino)ethanesulfonic acid (MES) 130 mmol L-1 pH 5.0 was chosen as background electrolyte (BGE). The temperature and the voltage were kept constant at 20°C and 15 kV respectively. For sample injection, hydrodynamic injection mode was used, with a pressure of 0.5 psi applied for 10 s. The wavelength was set at 214 nm. Under final conditions, LTG and the internal standard (IS) lidocaine were analyzed in less than 7 minutes. HF-LPME was evaluated in the three phase mode. The analyte was extracted from 4.0 mL of a basic donor phase (composed of 500 ?L of plasma and 3.5 mL of sodium phosphate solution 50 mmol L-1 pH 9.0) into an organic phase composed of 1-octanol immobilized in the pores of the hollow fiber, and further into an acidic acceptor phase (hydrochloric acid solution pH 4.0) placed in the lumen of the fiber. To evaluate DLLME, the plasma samples were pretreated to remove the proteins, and 500 ?L of plasma sample was mixed with 1 mL of acetonitrile. After that, 1,3 mL of the upper layer was added to 4 mL of sodium phosphate solution 50 mmol L-1 pH 9.0, and 120 ?L of chloroform (extracting solvent) was rapidly injected in the aqueous sample and 165 ?L of the sedimented phase was collected. Under the optimized conditions, both methods were linear over the plasmatic concentration range of 1.0-20.0 ?g mL-1 and the lower limit of quantification (LLOQ) was 1.0 ?g mL-1. Both methods showed good precision, accuracy, selectivity to LTG, with no carryover and the samples were stable under the studied conditions. The recovery were 54,3 and 23% to HF-LPME and DLLME respectively. The validated methods were successfully applied for the quantification of LTG in plasma samples of epileptic patients. The techniques were compared and HF-LPME was more advantageous for being more suitable to analysis of complex matrices using small amount of organic solvent, and also can be automated.
176

Propriedades de corrosão e caracterização química – metalográfica de próteses em aços inoxidáveis ISO 5832-9 e F138, removidas de pacientes

Silva, Elison da Fonseca e 26 November 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-05-03T13:18:17Z No. of bitstreams: 1 elisondafonsecaesilva.pdf: 5310395 bytes, checksum: c89f2c8b3846fc7ab92440accf66f534 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-05-13T13:33:58Z (GMT) No. of bitstreams: 1 elisondafonsecaesilva.pdf: 5310395 bytes, checksum: c89f2c8b3846fc7ab92440accf66f534 (MD5) / Made available in DSpace on 2017-05-13T13:33:58Z (GMT). No. of bitstreams: 1 elisondafonsecaesilva.pdf: 5310395 bytes, checksum: c89f2c8b3846fc7ab92440accf66f534 (MD5) Previous issue date: 2010-11-26 / Este trabalho estudou a composição química e metalográfica (microestrutura, tamanho de grão, teor de inclusões) de aços inoxidáveis austeníticos, desenvolvidos para aplicações como biomateriais, utilizados na fabricação de implantes ortopédicos, removidos de pacientes afetados por quadro inflamatório, e comparou as superfícies das amostras, através da Microscopia Eletrônica de Varredura (MEV) após ataque eletroquímico. Os resultados da análise química, por Espectrometria de Emissão Ótica e Microanálise por Dispersão de Energia (EDS), mostraram que todos os grupos apresentaram conformidade com as normas ASTM F138-92 e ABNT NBR ISO 5832-9:2008. O tamanho de grão foi determinado por Microscopia Ótica e Microscopia Eletrônica de Varredura (MEV). As superfícies das amostras foram analisadas por Microscopia Eletrônica de Varredura (MEV), depois de serem submetidos a ensaio de polarização cíclica potenciodinâmica em potencial de 50 mV após a região passiva em meio de solução de Ringer Lactato e solução de NaCl 0,9 mol.L-1na temperatura de 36,5 oC. Essas análises por MEV foram conduzidas nas amostras para identificar o tipo de corrosão apresentada. Concluiu-se que todos os implantes apresentavam tamanho de grão superior ao recomendado pela norma. Constatou-se também a presença de ferrita delta em oito dos doze implantes removidos, que de acordo com a norma ASTM 138-92, não deveria ser percebida microscopicamente com um aumento de 100 vezes. Verificou-se ainda que em meio de NaCl, o aço ISO 5832-9 ao contrário do aço F138, não apresentou nenhuma forma de corrosão localizada. Em solução de Ringer lactato, após ataque por 15 min. no potencial de 1000 mV/ECS foi notada a presença de pites no aço ISO 5832-9. O ensaio de polarização cíclica revelou que um dos aços, identificado como ISO 5832 9 apresentou resistência à corrosão localizada muito superior ao outro identificado como F 138, além de não liberar íons metálicos nas soluções eletrolíticas. Essa propriedade é principalmente atribuída ao aumento da estabilidade do filme passivo, que por sua vez, é favorecida pela presença do nitrogênio em solução sólida intersticial na austenita do aço ISO 5832-9. Os ensaios de polarização revelaram-se úteis para indicar a baixa resistência à corrosão por pites exibida “in-vitro” pelas próteses. As amostras do aço F 138 após serem submetidas ao ensaio eletroquímico em solução de Ringer lactato apresentaram perdas de 63% de níquel e 26% de ferro em relação à composição inicial. Tais elementos foram deslocados eletroquimicamente na forma iônica para a solução de Ringer lactato, onde formaram precipitados sendo, portanto, um forte indicador de que as reações sofridas pelos portadores das próteses foram motivadas por esses íons metálicos, que são posteriormente incorporados no organismo. Pretende-se com os resultados dessa pesquisa propor aos órgãos governamentais reguladores de normas técnicas e de vigilância sanitária, bem como a médicos e hospitais que exijam dos fabricantes de próteses de aços inoxidáveis laudos técnicos que atestem a qualidade dos implantes, onde cada lote de fabricação das peças seja acompanhado por certificados garantindo a composição química e as características metalográficas especificadas pelas norma existentes no Brasil. / This work has studied the chemical and metallographic composition (microstructure, grain size, inclusion rate) of austenitic stainless steels which were developed to be applied as biomaterials, and used in the production of orthopedical implants, removed from patients which had been affected by inflammation; it has also been compared the sample surfaces, by means of scanning electronic microscopy (SEM) after electrochemical attack. The results of chemical analysis, performed by optical emission spectroscopy and Energy Dispersive Spectroscopy (EDS) have shown that all samples are in agreement with the ASTM F138-92 e ABNT NBR ISO 5832-9:2008 regulations, whereas the grain size has been determined by optical microscopy and SEM. The surfaces of the samples were analyzed by SEM and EDS techniques; samples were submitted to potentiodynamic cyclic polarization tests in 50 mV potential after the passivation region in Ringer lactate and NaCl 0,9 mol.L-1 solutions at 36,5C; such SEM measurements were done to identify the type of corrosion over the samples. It has been concluded that all implants showed average grain sizes above the recommended by the regulations; also the presence of delta ferrite in eight of the twelve investigated implants has been seen, which according to the ASTM 138-92 regulation this would not been possible even with a 100-fold increase at the optical microscope. It has also been verified that in NaCl medium the ISO 5832-9 steel did not present any kind of localized corrosion, instead of F 138 steel; in Ringer lactate solution, after 15 minutes attack at 1000mV/SCE, has been noted the presence of pits for ISO 5832-9 steel. The cyclic polarization measurements have revealed that one of the investigated steels, named ISO 5832-9, presented a very high resistance to localized corrosion when compared to the F 138 samples, besides they did not release metallic ions to the electrolytic solutions. This characteristic can be mainly attributed to the increasing of the passivation film stability, which is also favored by the presence of nitrogen atoms in the solid solution composing the structure of ISO 5832-9 steel. The pit corrosion tests have shown very useful to indicate the low resistance to pit corrosion, present “in-vitro” in all the studied samples. The EDS mapping analysis of F 138 samples, submitted to electrochemical attack in Ringer lactate medium, have shown a loss of 63% of nickel and 26% of iron, when compared to the initial composition; such metals were electrochemically solubilized to the Ringer lactate solution, where they can probably precipitate from the solution, being a strong indication that the reactions taking place in the patients have been motivated by these metal ions, which can be incorporated by the human body. The obtained results of this work are the basis of a tentative proposition to the governmental organisms which are the responsible for the regulation of the technical specifications for the prosthesis producers, requiring from them technical reports assuring the quality for the implant pieces, i.e., for each manufacturing lot a description or a special certificate containing the chemical composition and the metallographic characteristics specified by the Brazilian laws.
177

Equações dispersivas : estabilidade orbital de ondas viajantes perióricas / Dispersive equations : orbital stability of periodic traveling waves

Andrade, Thiago Pinguello de, 1985- 09 August 2014 (has links)
Orientador: Ademir Pastor Ferreira / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Matemática Estatística e Computação Científica / Made available in DSpace on 2018-08-25T19:57:48Z (GMT). No. of bitstreams: 1 Andrade_ThiagoPinguellode_D.pdf: 2608603 bytes, checksum: 20935cf463b03d1c5c1390b127a42f4f (MD5) Previous issue date: 2014 / Resumo: Nesta tese estudamos estabilidade orbital de ondas viajantes periódicas para modelos dispersivos. O estudo de ondas viajantes iniciou-se em meados do século XVIII quando John S. Russell estabeleceu que ondas de água em um canal raso possui evolução constante. A estratégia geral para se obter a estabilidade consiste em provar que a onda viajante em questão minimiza um funcional conservado restrito a uma certa variedade. No nosso contexto, seguindo tais ideias, minimizamos o funcional restrito a uma nova variedade. Embora acreditamos que a teoria possa ser aplicada a outros modelos, nos restringimos às equações de Benjamin-Bona-Mahony (BBM) com termo não linear fracionário e Korteweg-de Vries modificada (mKdV). Além disso, resultados similares para a equação de Gardner são obtidos, usando uma estreita relação que esta possui com a mKdV / Abstract: In this thesis we study the orbital stability of periodic traveling waves for dispersive models. The study of traveling waves started in the mid-18th century when John S. Russel established that the flow of water waves in a shallow channel has constant evolution. The general strategy to obtain stability consists in proving that the traveling wave in question minimizes a conserved functional restricted to a certain manifold. In our context, following such ideas, we minimize such a functional restricted to a new manifold. Although we believe our theory can be applied to other models, we deal with the Benjamin-Bona-Mahony (BBM) equation with fractional nonlinear terms and modified Korteweg-de Vries (mKdV) equation. Besides, similar stability results for the Gardner equation are obtained, using a close relation between this equation and the mKdV / Doutorado / Matematica / Doutor em Matemática
178

[en] DETERMINATION OF SILICON AND ALUMINUM IN CRUDE OIL USING ENERGY DISPERSIVE X-RAY FLUORESCENCE SPECTROMETRY / [pt] DETERMINAÇÃO DE SILÍCIO E ALUMÍNIO EM PETRÓLEO POR ESPECTROMETRIA DE FLUORESCÊNCIA DE RAIOS-X POR DISPERSÃO DE ENERGIA

MARLIN JEANNETTE PEDROZO PEÑAFIEL 15 May 2018 (has links)
[pt] A determinação de diferentes níveis de silício e alumínio em petróleo é importante porque pequenas quantidades destes elementos podem produzir efeitos adversos nas refinarias devido à corrosão de equipamento ou afetar a qualidade dos produtos refinados. A espectrometria de fluorescência de raios-X por dispersão de energia (EDXRF) foi utilizada para desenvolver um método para a determinação de Si e Al em petróleo, onde estes elementos se encontram principalmente sob a forma de partículas sólidas de aluminossilicatos dispersas na amostra. Uma vez que os analitos não puderam ser determinados sem interferência diretamente no óleo, a fusão das amostras de petróleo foi realizada utilizando tetraborato de lítio. Em seguida, as amostras fundidas foram colocadas no centro de papéis de filtro de 10 mm de diâmetro, que foi colocado entre duas folhas de filme de polipropileno, para então ser fixado à cubeta para as medições no instrumento. A quantificação foi feita por meio de curvas analíticas no intervalo de concentração de 0 a 40 mg kg(-1) (para ambos os elementos) no material fundido final. O método desenvolvido, não sofreu interferência matriz uma vez que as amostras foram completamente decompostas e, posteriormente secas no substrato. Os resultados para os elementos foram estatisticamente comparáveis com os obtidos por espectrometria de absorção atômica com chama (FAAS). Além disso, os resultados concordaram com os obtidos nas amostras de programas de proficiência da ASTM. Amostras reais de petróleo, fornecidas pela Petrobras, também foram analisadas. As recuperações alcançadas se encontram entre 71 e 100 por cento para as diferentes amostras, o qual pode ser considerado satisfatório devido à dificuldade em se determinar esses elementos. Os limites de quantificação (10 vezes o desvio-padrão, n=10) encontrados para o Si e Al no petróleo foram de 0,7 e 1,1 mg kg(-1), respectivamente, mostrando o potencial do método proposto para a determinação de amostras com valores mais elevados destes elementos. / [en] It is important to determine silicon and aluminum at different levels in crude oils because of trace amounts of these elements may produce adverse effects in oil refining either by causing corrosion or by contaminating and affecting the quality of the refined products. Energy dispersive X-ray fluorescence spectrometry (EDXRF) was used to enable a reliable method for determination of Si and Al in crude oil, where these elements are found mainly in the form of solid aluminosilicate particles dispersed in the sample. Since the analytes could not be determined directly in the oil without interference, the fusing the crude oil samples was made using lithium tetraborate. Then, the fused samples were placed in the center of 10 mm diameter filter paper that were sandwiched between two polypropylene film foils and attached to the instrument cell for measurements. Quantification was made by using analytical curves in the concentration range from 0 to 40 mg kg (-1) (for both elements) in the final fused material. The method developed did not suffer from matrix effect once the sample matrix was completely decomposed and the sample solution dried in the substrate before measurements. The results for the elements were statistically comparable to the ones obtained by flame atomic absorption spectrometry (FAAS). In addition, for proficiency test samples, the results were in accordance to the ones reported by ASTM proficiency programs. Real samples of oil provided by Petrobras Company also were analyzed. Recoveries were achieved between 71 and 100 percent for different samples, which can be considerable satisfactory because of the difficulty in determine those elements. The limits of quantification (10 times the standard deviation. N = 10) found for silicon and aluminum in the oil were of 0.7 and 1.1 mg kg (-1), respectively, showing the potential of the proposed method to screen for samples with higher amounts of these elements.
179

Entangled states and coherent interaction in resonant media / Etats intriqués et interaction cohérente dans les milieux résonants

Chakhmakhchyan, Levon 21 July 2014 (has links)
Nous analysons les caractéristiques d'intrication de quelques matériaux à l'état solide ainsi que des systèmes particuliers d'atomes et de champs en interaction. Une étude détaillée de la riche structure de phase des modèles de spins de basse dimension, décrivant le minéral naturel d'azurite et les composés de coordination à base de cuivre, a révélé des régimes à comportement d'intrication des plus robustes. En utilisant l'approche des systèmes dynamiques, la structure de phase de certains modèles classiques en réseaux hiérarchiques (récursifs) a aussi été étudiée et, pour la première fois, la transition entre régime chaotique et régime périodique au moyen de la bifurcation tangente a été détectée.Nous présentons une description détaillée des propriétés d'intrication de trois atomes piégés dans la limite dispersive. Une relativement simple accordabilité de la force atomique d'interaction de ce système et son étroite relation aux problèmes de frustration magnétique est démontrée. Les effets de propagation de pulses laser intenses dans un système atomique de type [lambda] avec des forces d'oscillateurs différentes sont analysés. Les résultats obtenus sont d'extrême importance dans des problèmes d'information quantique, comme par exemple, dans l'analyse du mécanisme de transfert de population dans des milieux ayant les propriétés définies ci-avant. Enfin, nous avons analysé les effets dissipatifs dans un protocole de distillation de l'intrication à variable continue récemment proposé. Malgré des contraintes additionnelles sur les paramètres du protocole, il est encore possible d'implémenter ce schéma de distillation évoqué ci-avant dans les technologies émergentes. / The entanglement features of some solid state materials, as well as of particular systems of interacting atoms and fields are analyzed. A detailed investigation of the rich phase structure of low dimensional spin models, describing the natural mineral azurite and copper based coordination compounds, has revealed regimes with the most robust entanglement behavior. Using the dynamical system approach, the phase structure of some classical models on hierarchical (recursive) lattices has been also studied and, for the first time, the transition between chaotic and periodic regimes by means of tangent bifurcation has been detected.A detailed description of entanglement properties of three atoms trapped in a cavity within the dispersive limit is presented. A relatively simple tunability of the atomic interaction strength of the above system and its close relation to the problems of frustrated magnetism is shown. Furthermore, the propagation effects of two intense laser pulses in a medium of [lambda] atoms with unequal oscillator strengths are investigated. Obtained results are crucial in some problems of quantum information theory, as, e.g., in the analysis of population transfer mechanism in media possessing the above properties. Finally, the dissipation effects in a recently proposed compact continuous-variable entanglement distillation protocol have been analyzed. Despite additional constraints on the parameters of the protocol, the discussed entanglement distillation scheme in quantum memories is still possible to implement within emerging technologies.
180

Synthesis, optical and morphological characterization of pbse quantum dots for diagnostic studies: a model study

Ouma, Linda Achiengꞌ January 2013 (has links)
>Magister Scientiae - MSc / In this study PbSe quantum dots (QDs) were successfully synthesized via the organometallic and aqueous routes. Optical characterization was carried out using photoluminescence (PL) spectroscopy, structural and morphological characterization were carried out using X-ray diffraction (XRD) and transmission electron microscopy (TEM). Energy-dispersive X-ray spectroscopy (EDS) was used to determine the composition of the QDs. All the synthesized QDs were found to have emissions within the near-infrared region of the spectrum (≥1000 nm) with most of them being less than 5 nm in size. The aqueous synthesized QDs had a perfect Gaussian emission spectrum with a FWHM of ~23 nm indicating pure band gap emission and narrow size distribution respectively. The QDs were determined to have a cubic rock-salt crystal structure consistent with bulk PbSe. The aqueous synthesized QDs were however not stable in solution with the QDs precipitating after approximately 48 h. The organometallic synthesized QDs were transferred into the aqueous phase by exchanging the surface oleic acid ligands with 11-mercaptoundecanoic acid ligands. The ligand exchanged QDs were however stable in solution for over two weeks. The effects of reaction parameters on the optical and structural properties of the organometallic synthesized QDs were investigated by varying the reaction time, temperature, ligand purity, lead and selenium sources. It was observed that larger QDs were formed with longer reaction times, with reactions proceeding faster at higher reaction temperatures than at lower temperatures. Varying the ligand purity was found to have minimal effects on the properties of the synthesized QDs. The lead and selenium sources contributed largely to the properties of the QDs with lead oxide producing spherical QDs which were smaller compared to the cubic QDs produced from lead acetate. TBPSe was seen to produce smaller QDs as compared to TOPSe. The cytotoxity of the synthesized QDs was determined following the WST-1 cell viability assay with the QDs being found to be non-toxic at all the tested concentrations

Page generated in 0.0931 seconds