• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 43
  • 13
  • 12
  • 7
  • 7
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 156
  • 49
  • 44
  • 32
  • 32
  • 24
  • 23
  • 16
  • 15
  • 14
  • 14
  • 14
  • 13
  • 13
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avaliação da qualidade de vida de portadores de marcapasso cardíaco artificial em Goiânia, Goiás / Quality of life of artificial cardiac pacemaker patient in Goiânia, Goiás

ZATTA, Laidilce Teles 14 April 2010 (has links)
Made available in DSpace on 2014-07-29T15:04:27Z (GMT). No. of bitstreams: 1 dissertacao Laidilce T Zatta.pdf: 353033 bytes, checksum: 50158c4aade92a4a9fe7e29429d42d86 (MD5) Previous issue date: 2010-04-14 / Health related quality of life includes social, emotional and physical well-being of individuals, the impact of some treatments used to control health problems and the individual's ability to lead his own life. One of these treatments currently used is a device called artificial pacemaker, and patients have reported changes in daily life after implantation, which may influence the quality of their lives. It is a descriptive exploratory study that aimed to evaluate the quality of life of cardiac pacemakers patients using a generic instrument- SF-36 ® (Medical Outcomes Study 36-Item Short-Form Health Survey) and other specific instrument - AQUAREL (Assessment of Quality of Life and Related Events). We interviewed 84 patients with permanent pacemaker after six or more months of implantation, and used two instruments to assess quality of life: SF-36 and AQUAREL. Respondents had an average age 59.9 years, 58.3% were female, catholic (70.2%), had completed elementary school (81%). They self-reported themselves as white (59.5%), they had a steady partner (69%) and monthly family income below two minimum wages (51.3%). The implantation time varied between one and 28 years (median three years), the principal cause was the Chagas disease (76.2%), 73.8% were with the first generator, the predominant type of stimulation was DDDR (67,9%) and they were functional class I (57.1%). The median scores for SF-36 dimensions were higher in Social Functioning (100.00) and Mental Health (68.00) dimensions; the lowest scores were obtained in Role Limitations Resulting from Physical Health (00.00) and Role Limitations Resulting from Emotional Problems (33.33) dimensions. The median scores of AQUAREL were 81.25 for Chest Discomfort, Arrhythmias (80.00) and 71.43 for Dyspnea. Cronbach's Alpha ranged between 0.916 and 0.688 for SF-36 dimensions and between 0.852 and 0.693 for AQUAREL, indicating good reliability of the instruments. It was observed that the perception of individuals facing the aspects analyzed in each dimension of SF-36 and AQUAREL is not homogeneous, being influenced by religion, gender, age, race, presence of children, work, income level, education, number of implants and the reason of the implant. The lower scores indicate which aspects need attention from the health team to contribute to the quality of life of these patients. / A qualidade de vida relacionada à saúde engloba, além dos aspectos sociais, emocionais e de bem-estar físico dos indivíduos, o impacto de alguns tratamentos empregados para controle de problemas de saúde e a habilidade do indivíduo de conduzir sua própria vida. Um dos tratamentos é o implante de marcapasso cardíaco artificial definitivo, cujos portadores relatam alterações na vida diária após o implante, que podem influenciar na qualidade de suas vidas. Trata-se de estudo descritivo exploratório, que objetivou avaliar a qualidade de vida dos portadores de marcapasso cardíaco artificial por meio de um instrumento genérico - SF-36® (Medical Outcomes Study 36-Item Short-Form Health Survey) e outro específico - AQUAREL (Assessment of Quality of Life and Related Events). Foram entrevistados 84 portadores de marcapasso cardíaco artificial definitivo após seis ou mais meses de implante. Os entrevistados tinham idade média de 59,9 anos, 58,3% eram do sexo feminino, católicos (70,2%), possuíam escolaridade fundamental incompleta (81%). Autodenominaram-se brancos (59,5%), possuíam companheiro fixo (69%) e renda mensal familiar inferior a dois salários mínimos (51,3%). O tempo de implante variou entre um e 28 anos (mediana três anos), a causa base foi a doença de Chagas (76,2%), 73,8% estavam com o 1º gerador, o tipo de estimulação predominante foi DDDR (67,9%) e pertenciam à classe funcional I (57,1%). As medianas dos escores do SF-36 foram maiores nas dimensões Aspectos Sociais (100,00) e Saúde Mental (68,00) e os menores escores foram obtidos em Aspectos Físicos (00,00) e Aspectos Emocionais (33,33). As medianas dos escores do AQUAREL foram 81,25 para Desconforto no Peito, 80,00 para Arritmias e 71,43 para Dispnéia ao Exercício. O alfa de Cronbach variou entre 0,916 e 0,688 para as dimensões do SF-36 e entre 0,852 e 0,693 para o AQUAREL, indicando boa confiabilidade dos instrumentos. Observou-se que a percepção dos indivíduos frente aos aspectos analisados em cada dimensão do SF-36 e AQUAREL não é homogênea, sendo influenciada pela religião, sexo, faixa etária, raça, presença ou não de filhos, trabalho, faixa de renda, escolaridade, número de implante e motivo do implante. Os menores escores indicam quais aspectos precisam de maior atenção por parte da equipe de saúde. Reforça-se a necessidade da atuação qualificada de uma equipe multiprofissional que acompanhe o portador de marcapasso, minimizando os fatores que possam estar interferindo na sua qualidade de vida.
122

Estudo clínico randomizado em chagásicos submetidos à terapia de ressincronização cardíaca (TRC - Chagásico) / Randomized clinical study in Chagas disease undergoing cardiac resynchronization therapy (CRT - Chagas` Disease)

Uelra Rita Lourenço 12 May 2016 (has links)
INTRODUÇÃO: A terapia de ressincronização cardíaca(TRC) tem se mostrado alternativa eficiente para pacientes com Insuficiência Cardíaca (IC) em uso terapia medicamentosa otimizada, com fração de ejeção reduzida e QRS largo. Apesar dos resultados positivos em pacientes de diversas etiologias, dados a despeito do efeito dessa terapia na cardiopatia chagásica são extremamente raros na literatura. OBJETIVOS: Avaliar a evolução clínica e funcional de pacientes chagásicos submetidos à terapia de ressincronização cardíaca, por meio de estudo clínico randomizado. CASUÍSTICA E MÉTODOS: Foram incluídos pacientes com cardiopatia chagásica, em Classe funcional II, III ou IV da NYHA, em uso de terapia medicamentosa otimizada, fração de ejeção <= 35% e duração do QRS largo. O presente estudo clínico é prospectivo, de intervenção, randomizado, cego, com crossover e comparou as respostas clínicas e funcionais após duas fases: período de 2 meses com a TRC ligada e período de 2 meses com a TRC desligada. As variáveis analisadas foram distância percorrida no teste de caminhada de 6 minutos, classe funcional (NYHA), pontuação no teste de qualidade de vida do questionário de Minnesota, pontuação no teste de capacidade funcional no questionário SF 36, pico de extração de oxigênio no teste cardiopulmonar e fração de ejeção do ventrículo esquerdo. RESULTADOS: Foram randomizados 34 pacientes sendo que seis não conseguiram completar as duas fases do estudo. A média da distância percorrida no Teste de Caminhada de 6 minutos foi 60 metros maior no grupo TRC ligada (500,3 versus 439,8 metros; p<0,01), o teste de Qualidade de Vida (Questionário de Minnesota) apresentou escores estatisticamente melhores nos pacientes com TRC ligada (diferença entre os dois grupos de 12,2 pontos, p<0,05). A Capacidade Funcional avaliada pelo questionário SF 36 apresentou resultado a favor da TRC ligada (p<0,01). De modo semelhante, a Classe Funcional (NYHA) média foi significativamente inferior neste grupo (p<0,05). As variáveis estudadas no Teste Cardiopulmonar e os parâmetros Ecocardiográficos não atingiram diferenças com significância estatística entre os dois grupos. CONCLUSÃO: Os resultados encontrados neste estudo suportam o valor terapêutico da TRC em indivíduos com insuficiência cardíaca de etiologia chagásica com QRS largo. A estimulação biventricular promoveu melhora significativa dos sintomas, qualidade de vida, capacidade funcional e da distância percorrida no teste de caminhada. Estudos subsequentes são necessários para avaliação dos efeitos clínicos a longo prazo e o impacto em mortalidade desta modalidade terapêutica nos pacientes com cardiopatia chagásica. / BACKGROUND: Cardiac Resynchronization Therapy (CRT) has been shown one effective alternative for patients under optimal medical therapy, reduced ejection fraction (EF) and wide QRS. Despite the positive results in patients of several etiologies, data from this therapy in Chagas heart disease are extremely rare in the literature. OBJECTIVES: To evaluate the clinical and functional results of Chagas patients undergoing CRT through a randomized clinical trial. METHODS: There were included patients with Chagas cardiomyopathy, functional class II, III or IV of NYHA, under optimal drug therapy, EF <= 35% and wide QRS. This prospective, randomized, blinded, crossover study compared the clinical and functional responses after two phases: a two-month period of CRT-on and a two-month period of CRT-off. The outcomes analyzed were: walked distance in 6 minutes, functional class (NYHA), quality of life by the Minnesota Living with Heart Failure Questionnaire score, functional capacity by the questionnaire SF 36 score, Oxygen Extraction Peak in Cardiopulmonary Test and EF of the Left Ventricle. RESULTS: Thirty four patients were randomized but six patients failed to complete both study periods. The average distance walked in 6 minutes was 60 meters higher in CRT-on group (500.3 vs. 439.8 meters, p <0.01), the Quality of Life (Minnesota Questionnaire) showed scores significantly better in patients with CRT- on (difference of scores between the two groups: 12.2, p <0.05). The functional capacity assessed by the SF-36 questionnaire showed better results in favor of CRT-on group (p <0.01). Similarly, the functional class (NYHA) was significantly lower in this group (p <0.05). The variables studied in Cardiopulmonary Testing and Echocardiographic parameters did not reach statistical significance between the two groups. CONCLUSION: The results of this study support the therapeutic value of CRT in patients with heart failure due to Chagas disease with wide QRS. The biventricular pacing significantly improved symptoms, quality of life, functional capacity and the distance walked in 6 minutes. Further studies are needed to evaluate the clinical long-term effects and the impact on mortality of this therapeutic modality in patients with Chagas heart disease.
123

Estudo da segurança e da estabilidade do implante de cabo-eletrodo atrial direito pela via epidemiocárdiaca através do seio transverso em modelo animal suíno / Evaluation of safety and stability of right atrial lead implantation by epimyocardial access through the transverse sinus in a swine model

Sávia Christina Pereira Bueno 13 June 2013 (has links)
Introdução: Embora o implante de marcapasso atrioventricular pela via endovenosa seja considerado o estado da arte, situações clínicas e técnicas que podem impossibilitar o implante transvenoso de cabos-eletrodos têm sido cada vez mais frequentes, tornando-se necessária a proposição de abordagens cirúrgicas alternativas. Objetivos: O presente estudo visou o implante de marcapasso atrioventricular utilizando nova técnica para implante de cabo-eletrodo atrial no átrio direito, com o objetivo de avaliar no período intra-operatório e nos 30 primeiros dias de seguimento: a segurança e a reprodutibilidade do procedimento cirúrgico; a taxa de deslocamento dos cabos-eletrodos; as condições de estimulação e sensibilidade; as alterações morfológicas na cavidade pericárdica e as alterações histopatológicas epimiocárdicas. Métodos: Sob anestesia geral, foram operados 10 porcos adultos da raça Large White. Os cabos-eletrodos foram implantados, sob visão direta, no ventrículo esquerdo e no átrio direito, pelo seio transverso, através de toracotomia anterolateral esquerda. As condições de estimulação e de sensibilidade para os cabos-eletrodos atrial e ventricular, nas configurações unipolar e bipolar, foram avaliadas no intra-operatório, pós-operatório imediato, no 7º e 30º dias de pós-operatório. Ao final do estudo, os animais foram reoperados por toracotomia longitudinal mediana para observação das aderências pericárdicas e análise das condições histopatológicas da junção entre o cabo-eletrodo e o epimiocárdico. Resultados: Todos os animais permaneceram vivos até o último dia do estudo, não tendo ocorrido complicações intra-operatórias graves. As condições de estimulação e sensibilidade para os cabos-eletrodos atriais e ventriculares, nas configurações unipolar e bipolar, mantiveram-se estáveis ao longo do estudo e apresentaram comportamento semelhante. Notou-se aumento progressivo dos limiares atriais, variando de 0,50 ± 0,38 a 1,86 ± 1,31 volts nos períodos intra-operatório e 30o pós-operatório, respectivamente. Comportamento semelhante foi observado para os limiares ventriculares, que variaram de 0,43 ± 0,23 volts, no intra-operatório, a 1,22 ± 0,49 volts, no 30o pós-operatório. As medidas de impedância atrial e ventricular apresentaram uma discreta queda ao longo do tempo, sendo que a impedância atrial variou de 486,80 ± 126,35 a 385,0 ± 80,52 Ohms no período intra-operatório e 30o pós-operatório, respectivamente. A impedância ventricular variou de 700,40 ± 203,67 Ohms, no intra-operatório, a 409,30 ± 58,96 Ohms, no 30o pós-operatório. A sensibilidade, tanto em átrio quanto em ventrículo, mostrou-se estável a partir do pós-operatório imediato. A inspeção da cavidade pericárdica mostrou aderências em todos os animais e em todas as regiões avaliadas, não sendo observados derrame ou constrição pericárdica. A análise microscópica mostrou que o contato com os cabos-eletrodos provocou espessamento do epimiocárdio no átrio direito, ventrículo esquerdo e na artéria pulmonar. A cicatriz formada na junção entre o cabo-eletrodo e o epimiocárdio atrial foi semelhante à formada na região do implante dos cabos-eletrodos ventriculares. Conclusões: O implante do cabo-eletrodo atrial direito pelo seio transverso foi seguro e reprodutível. A efetividade do procedimento foi confirmada pelas condições estáveis de estimulação e de sensibilidade durante o período de seguimento pós-operatório. A única alteração morfológica encontrada na cavidade pericárdica foi a formação de aderências. Ocorreu adequada cicatrização na junção entre o cabo eletrodo e o epimiocárdio atrial / Introduction: Although transvenous access for atrioventricular pacemaker implantation is considered the state of the art, clinical and technical situations that may impede transvenous leads implantation have become increasingly common, making it necessary the proposal of new surgical approaches. Objectives: The present study was design to perform the implant of atrioventricular pacemaker using a new technique for placement of the atrial lead in the right atrium, aiming to evaluate in the intraoperative period and during the first 30 days of follow-up: the safety and reproducibility of the surgical procedure; lead dislodgment rate; conditions of pacing and sensing; morphological changes in the pericardium, as well as, histopathological changes in the epimyocardium. Methods: A total of 10 Large White adult pigs underwent pacemaker implantation under general anesthesia. By using an anterolateral thoracotomy, leads were implanted under visual guidance in the left ventricle and in the right atrium through the transverse sinus. Pacing and sensing parameters, in unipolar and bipolar modes, were obtained during the intraoperative and immediate postoperative period and on the 7th and the 30th postoperative day. At the end of the study, all animals underwent reoperation by thoracotomy through a median longitudinal sternotomy for evaluation of pericardial adhesions and histopathological analysis of the junction between the lead and epimyocardial wall. Results: All animals were alive until the end of the study and there were no serious intraoperative complications. Pacing and sensing parameters for atrial and ventricular leads in both unipolar and bipolar modes remain stable throughout the study and showed similar performance. We observed a progressive increase in atrial thresholds, ranging from 0.50 ± 0.38 to 1.86 ± 1.31 volts, during the intraoperative and on the 30-day postoperative, respectively. Similar result was observed for ventricular thresholds, which ranged from 0.43 ± 0.23 volts, intraoperatively, to 1.22 ± 0.49 volts on the 30-day postoperative. Atrial and ventricular impedance measurements decreased slightly over time, and the atrial impedance ranged from 486.80 ± 126.35 to 385.0 ± 80.52 Ohms during the intraoperative and on the 30-day postoperative, respectively. Ventricular impedance ranged from 700.40 ± 203.67 Ohms, intraoperatively, to 409.30 ± 58.96 Ohms, on the 30-day postoperative. Both atrial and ventricular sensing measurements remain stable since the immediate postoperative period. Pericardial adhesions were found in all animals and in all studied regions. There was no noticeable pericardial effusion or myocardial constriction. Microscopic analysis showed that contact with the electrode had caused thickening of the right atrium, left ventricle and pulmonary artery. Similar scar formation was found at the interface between atrial lead and epimyocardial, such as ventricular lead and epimyocardial. Conclusion: Implantation of the right atrial lead through the transverse sinus was safe and reproducible. The effectiveness of the procedure was confirmed by stable conditions of pacing and sensing parameters throughout the postoperative follow-up. Pericardial adhesion was the only change found in the pericardial morphology. There was adequate scar formation between the interface of atrial lead and the epimyocardial
124

Analyse et validation des propriétés des cellules souches du muscle squelettique adulte concernant leur différenciation en myocytes pacemaker : Vers une thérapie cellulaire des maladies du rythme cardiaque / Analysis and validation of the ability of skeletal muscle-derived stem cell to differentiate into pacemaker myocytes : toward a stem cell therapy of heart rhythm disorders

Davaze, Romain 24 March 2016 (has links)
Nous sommes sur le point de montrer que le muscle squelettique adulte contient une population de cellules souches capables de se différencier in vitro en cellules cardiaques présentant des battements automatiques. Ces cellules pulsantes différenciées en culture, possèdent toutes les caractéristiques d’un type de cellules spécialisées dans la conduction cardiaque : les cellules pacemaker du sinus atrial De même, lorsque ces cellules souches sont transplantées chez des souris mutantes qui présentent des troubles de la conduction cardiaque, elles sont retrouvées différentiées en cellules pacemaker dans le cœur et améliorent significativement les troubles du rythme de ces souris. Ces résultats indiquent qu’il est important d’isoler une population avec le même potentiel à partir du muscle squelettique humain étant donné le potentiel réparateur extrêmement prometteur de ces cellules souches adultes pour leur utilisation en thérapie cellulaire des dysfonctionnements du rythme cardiaque. Une analyse préliminaire sur le microcèbe, modèle primate, nous a d’ores et déjà permis de valider la différentiation in vitro des cellules souches dérivées du muscle squelettique en cellules pacemaker. / We show that adult multipotent Muscle-Derived Stem Cells (MDSC) have the ability to differentiate into cardiac pacemaker cells in vitro and in vivo. In vitro, differentiated beating pacemaker-like cells remain active for months and express all the markers of native cardiac pacemakers. They show both hyperpolarization-activated “funny” current (If) and b-adrenergic- and cholinergic-responsive spontaneous Ca2+ transients. In vivo, systemic injection of MDSC from wt muscle significantly improved heart rhythm in severely bradycardic mutant CaV1.3-/- mice. This functional recovery was accompanied by differentiation of donor-derived CaV1.3-expressing cells in the sinoatrial node. MDSC from the primate Microcebe revealed a similar ability to differentiate in vitro into functional pacemaker-like cells. MDSC thus represent a unique, non-tumorigenic and directly transplantable stem cell source shown to efficiently engraft in mutant mouse heart and correct human-mirrored severe rhythm disorders.
125

Pacinchagas: estratificação de risco em chagásicos portadores de marca-passo definitivo / Pacinchagas: risk stratification in pacemaker patients with chronic chagasic cardiomyopathy

Giselle de Lima Peixoto 05 December 2016 (has links)
Introdução - Em pacientes com doença de Chagas a evolução para cardiomiopatia chagásica crônica (CCC) ocorre em cerca de 20-40%, e as principais causas de morte são insuficiência cardíaca (IC), morte súbita e eventos tromboembólicos. A CCC pode comprometer o sistema de condução, e representa uma das mais frequentes indicações de implante de marca-passo definitivo (MPD) no Brasil. Inúmeras variáveis já foram avaliadas na tentativa de estratificar o risco destes pacientes, no entanto, pacientes com CCC portadores de MPD foram excluídos dos principais estudos a esse respeito. Objetivos - Primário: 1. Determinar as variáveis clínico-funcionais preditoras de morte; 2. Elaboração de escore de risco de mortalidade total. Secundário - Determinar a taxa de eventos cardiovasculares. Métodos: Estudo prospectivo, unicêntrico, observacional, realizado em pacientes com CCC e MPD. Na inclusão, os pacientes foram submetidos a questionário clínico-funcional, eletrocardiograma, ecocardiograma e avaliação eletrônica do MPD. Os pacientes foram seguidos por pelo menos 24 meses. Regressão logística foi utilizada para identificação de preditores de mortalidade total. Resultados - Foram incluídos 493 pacientes e durante o seguimento, ocorreram 80 óbitos (16,2%). O modelo final de regressão logística múltipla apresentou calibração (teste de Hosmer Lemeshow 0,933), discriminação (área sob a curva 0,74) e performance global (escore de Brier 0,12) adequados, e identificou cinco preditores independentes de morte: classe funcional NYHA III/IV (OR [odds ratio] 4,33; IC95% 1,76-10,64; p=0,001), cardiomegalia avaliada pela radiografia de tórax (OR 2,31; IC95% 1,21-4,39; p=0,011), fração de ejeção do ventrículo esquerdo <= 40% (OR 2,32; IC95% 1,34-4,01; p=0,003), sexo masculino (OR 2,01; intervalo de confiança 95% [IC95%] 1,17-3,47; p=0,011) e fibrilação atrial (OR 1,78; IC95% 1,00-3,16; p=0,049). A pontuação para cada uma destas variáveis para composição do escore foi de 15, 8, 8, 7 e 6 pontos, respectivamente. Os pacientes foram divididos em três grupos de risco conforme pontuação total: baixo risco (0-7 pontos), médio risco (8-15 pontos) e alto risco ( > 16 pontos). A validação interna do modelo final foi efetuada pela técnica de reamostragem de bootstrap, baseado em 200 replicações. Conclusão: Este estudo identificou preditores independentes de morte e elaborou escore de risco de fácil aplicação clínica e específico para pacientes com CCC e MPD / Introduction - Chronic chagasic cardiomyopathy (CCC) develops in roughly 20-40% of Chagas disease patients and the main causes of death are heart failure, sudden death and thromboembolic events. CCC compromises the heart conduction system and represents a common indication for pacemaker implantation in Brazil. Studies aiming to identify risk factors to better stratify patients with CCC did not include pacemaker users. Objectives - Primary: 1. Identify predictors of death; 2. Create a risk score for mortality. Secondary - Determine the rate of cardiovascular events. Methods - Observational, unicentric and prospective study in CCC patients with pacemaker. The patients were submitted to clinical and pacemaker evaluation, electrocardiogram and echocardiogram. They were followed for at least 24 months. We applied logistic regression in order to identify predictors of death. Results - Four hundred ninety-three patients were included and during the follow-up, 80 patients (16.2%) died. The final multivariate logistic regression model yielded proper calibration (Hosmer Lemeshow test 0.933), discrimination (area under the curve 0.74) and global performance (Brier score 0.12). Five predictors of death were identified: heart failure functional class III or IV (OR [odds ratio] 4.33; 95% confidence interval [95%CI] 1.76- 10.64; p=0.001); cardiomegaly on radiography (OR 2.31; 95%CI 1.21-4.39; p=0.011); left ventricular ejection fraction <= 40% (OR 2.32; 95%CI 1.34-4.01; p=0.003); male gender (OR 2.01; 95%CI 1.17-3.47; p=0.011) and atrial fibrillation (OR 1.78; 95%CI 1.00-3.16; p=0.049). Each variable contributes to the risk score with 15, 8, 8, 7 and 6 points, respectively. We calculate risk scores for each patient and defined three groups: low risk (0-7 points), intermediate risk (8-15 points) and high risk ( > 16points). Internal validation was performed by means of bootstrap technique, based in 200 replications. Conclusions - This study identified predictors of death and created a simple and specific risk score for CCC patients with pacemaker
126

Efeitos da terapia de ressincronização cardíaca (TRC) sobre a perfusão miocárdica: correlações clínico-funcionais / Effects of cardiac resynchronization therapy (CRT) on myocardial perfusion: clinical and functional correlations

Simone Cristina Soares Brandão 17 September 2008 (has links)
Introdução: a cintilografia cardíaca com MIBI-99mTc sincronizada ao eletrocardiograma (gated SPECT) avalia integridade celular, perfusão miocárdica e função global e regional do ventrículo esquerdo (VE). A terapia de ressincronização cardíaca (TRC) pode melhorar os sintomas de insuficiência cardíaca (IC), mas seus benefícios sobre a função do VE são menos pronunciados. Objetivos: avaliar se as mudanças na captação miocárdica do MIBI-99mTc após a TRC estão associadas à melhora clínica, à redução do QRS ao eletrocardiograma e ao desempenho do VE e se a gated SPECT adiciona informação na seleção e acompanhamento de pacientes para a TRC. Método: trinta pacientes (idade media 59 ± 11 anos, 47% masculinos) com miocardiopatia dilatada não isquêmica, IC classe funcional III ou IV da New York Heart Association com tratamento medicamentoso otimizado, bloqueio de ramo esquerdo e fração de ejeção do ventrículo esquerdo (FEVE) inferior a 35% participaram deste estudo. Foram avaliados pré e três meses após TRC as seguintes variáveis: classe funcional de IC, duração do QRS, FEVE pela ecocardiografia, captação miocárdica do MIBI-99mTc (%) ao repouso e após estresse com adenosina, volumes diastólico (VDF) e sistólico finais (VSF) do VE, motilidade e espessamento regionais nas paredes do VE pela Gated SPECT. Após TRC, os pacientes foram divididos em dois grupos de acordo com a melhora na FEVE: grupo 1 (G1=12 pacientes) com aumento 5 pontos absolutos; e grupo 2 (G2=18 pacientes) sem aumento significante. Resultados: após TRC, ambos os grupos melhoraram significantemente a classe funcional de IC, reduziram QRS e aumentaram a captação miocárdica do MIBI-99mTc nas paredes ântero-septal e ínfero-septal. Apenas G1 apresentou mudanças favoráveis no VDF, VSF, motilidade e espessamento regionais do VE. Pré TRC, pela análise univariada, o VDF e ESV foram estatisticamente maiores no G2 em relação ao G1 (VDF: 477 ± 168 mL vs. 276 ± 94 mL, p<0,001; VSF: 401 ± 154 mL vs. 220 ± 85 mL, p<0,001, G2 e G1, respectivamente). A captação miocárdica do MIBI-99mTc foi menor no G2 em relação ao G1 nas paredes anterior (60 ± 10% vs. 67 ± 7%, p=0,049, repouso) e inferior (48 ± 10% vs. 59 ± 11%, repouso, e 47 ± 10% vs. 58 ± 9%, p=0,003, após estresse). A soma dos escores de hipocaptação após estresse foi significantemente maior no G2 em relação ao G1 (14 ± 9 e 9 ± 4, G2 e G1, respectivamente, p=0,039). Pela análise multivariada, o VDF foi o único preditor independente de aumento na FEVE após terapia, p=0,01. O ótimo ponto de corte do VDF pela curva ROC para predizer melhora na FEVE após terapia foi 315 mL com sensibilidade de 89% e especificidade de 94%. Conclusões: A TRC aumentou a captação miocárdica regional de MIBI-99mTc, melhorou a classe funcional de IC e reduziu QRS independentemente da melhora do desempenho cardíaco. Após TRC, o aumento da FEVE ocorreu em corações menos dilatados e com uma maior captação miocárdica regional do MIBI-99mTc, principalmente na parede inferior / Background: gated myocardial scintigraphy with 99mTc-MIBI (gated SPECT) evaluates myocyte integrity, myocardial perfusion and global and regional left ventricular (LV) function. Cardiac resynchronization therapy (CRT) may improve heart failure (HF) clinical symptoms, but its benefits for LV function are less pronounced. Objectives: we assessed whether changes on myocardial 99mTc-MIBI uptake post-CRT are related to improvement in clinical HF symptoms, reduction in QRS duration and improvement in LV performance, and whether gated SPECT with 99mTc-MIBI adds information to selection and follow-up of patients undergoing CRT. Methods: thirty patients (mean age 59 ± 11, 47% male) with nonischemic dilated cardiomyopathy, chronic HF in New York Heart Association functional class III or IV with optimized clinical treatment, left bundle-branch block, and LV ejection fraction (LVEF) inferior to 35% participated to this study. Pre- and 3 months post-CRT, the variables analyzed were: HF functional class, QRS duration, LVEF by echocardiography, myocardial 99mTc-MIBI uptake (%) at rest and after adenosine stress, LV end-diastolic (EDV) and end-systolic volumes (ESV), regional LV motion and thickness by gated SPECT. Post-CRT, patients were divided into 2 groups according to LVEF improvement: group 1 (G1=12 patients) with increase in LVEF5points and group 2 (G2=18 patients) without significant increase. Results: post-CRT, both groups improved significantly in HF functional class, reduced QRS width and increased antero-septal and infero-septal wall 99mTc-MIBI uptake. Only G1 had favorable changes in EDV, ESV, and LV regional motion and thickness. Pre- CRT, by univariate analysis, EDV and ESV were statistically higher in G2 compared with G1 (EDV: 477 ± 168 mL vs. 276 ± 94 mL, p<0.001; ESV: 401 ± 154 mL vs. 220 ± 85 mL, p<0.001, G2 and G1, respectively). Myocardial 99mTc-MIBI uptake was lower in G2 compared with G1 in the anterior wall (60 ± 10% vs. 67 ± 7%, p=0.049, at rest) and inferior wall (48 ± 10% vs. 59 ± 11%, at rest, and 47 ± 10% vs. 58 ± 9%, p=0.003, after adenosine stress). Summed stress score was significantly higher in G2 compared to G1 (14 ± 9 vs. 9 ± 4, G2 and G1, respectively, p=0.039). By multivariate analysis, EDV was the only independent predictor of LVEF increase posttherapy, p=0.01. By ROC curve, optimal EDV cutoff point was 315mL with 89% of sensitivity and 94% of specificity. Conclusions: CRT increased myocardial 99mTc- MIBI uptake, improved HF functional class, and reduced QRS width independently of LV performance improvement. Post-CRT, LVEF increase occurred in hearts less dilated showing higher regional myocardial 99mTc-MIBI uptake, mainly in the inferior wall
127

Externí kardiostimulátor / External pacemaker

Lank, Petr January 2008 (has links)
This master´s thesis deals with the problem of heart stimulation by using external pacemaker. Such external pacemaker is used for a short – time stimulation of patient to overcome the time before the implantation of such apparatus. The master´s thesis informs about the basic function of heart and possible heart disorders which are treated by pacemaker. Great deal of master´s thesis is devoted to the design of external pacemaker wiring. This section describes the possibilities of controlling the pacemaker, circuits for detection R-R interval, a design of output circuit eith regard to required of stimulation and pacemaker feeding. The program Pspice was used to check the functional appropriateness of designed circuits and it was successively simulated in a non - soldering field.
128

Elektromagnetická interference kardiostimulátorů / Electromagnetic interference and pacemakers

Kulík, Jindřich January 2008 (has links)
This thesis deals with electromagnetic compatibility of implantable electro-medical devices using in cardiology. The main aim of this thesis is detection of the resistance of implantable pacemakers (PM) and implantable cardioverter defibrillators (ICD) to the electromagnetic interference. In the first part of this thesis, a function of the heart, which is necessary for understanding of PM and ICD operation, is described. The function and construction of PM and ICD is detailed in the theoretical part as well. The next part is focused on the electromagnetic compatibility. The next part is description of the measurement method and the experimental arrangement used for practical experiments with electromagnetic resistance of PM and ICD.
129

The short term influence of right ventricular pacing burden on echocardiographic and spiroergometric parameters in patients with preserved left ventricular ejection fraction

Youssef, Akram, Pfluecke, Christian, Dawid, Maciej, Ibrahim, Karim, Günther, Michael, Kolschmann, Steffen, Richter, Utz, Francke, Alexander, Wunderlich, Carsten, Christoph, Marian 22 April 2024 (has links)
Background The incidence of worsened clinical outcome due to high right ventricular (RV) pacing burden in patients with preserved left ventricular function remains controversial. Objective To investigate the impact of RV pacing on several echocardiographic and spiroergometric parameters. Methods In 60 pacemaker patients with preserved left ventricular ejection fraction (LVEF) serial echocardiographies and spiroergometries were performed over a time course of 12 months. Additionally, in 48 patients retrospective echocardiographic analyses of the LV- and RV function were carried out up to 24 months after pacemaker implantation. Results The patients were divided into two groups: The high RV pacing burden group (hRVP: ≥ 40%) and the low RV pacing group (lRVP < 40%) according to the definitions in previous randomized MOST and DAVID trials. After a period of 12-month pacemaker therapy no changes to left ventricular end diastolic diameter (LVEDD), left ventricular end systolic diameter (LVESD), LVEF, E/A-ratio; E/E′-ratio and tricuspid annular plane systolic excursion (TAPSE) could be revealed, independently of the RV pacing burden. Additionally, after 24-month long term follow-up there were no differences in LVEF and TAPSE in both groups. Accordingly, no relevant changes of peak exercise capacity, ventilatory anaerobic threshold or maximal oxygen consumption could be demonstrated independently of the RV pacing. Conclusions In pacemaker patients with preserved LVEF the burden of RV pacing has no adverse influence on several echocardiographic and spiroergometric surrogate parameters of pacemaker-induced cardiomyopathy after a follow-up of 12 to 24 month. Despite this, screening for pacemaker induced cardiomyopathy should be performed especially in the presence of new heart failure symptoms.
130

O efeito da estimulação elétrica ventricular direita em pacientes com insuficiência cardíaca crônica sistólica secundária à cardiomiopatia chagásica.

Parra, Andrelisa Vendrami 19 January 2012 (has links)
Made available in DSpace on 2016-01-26T12:51:39Z (GMT). No. of bitstreams: 1 andrelisavendramiparra_tese.pdf: 942682 bytes, checksum: bd373115099c234d8c536d942f318ec0 (MD5) Previous issue date: 2012-01-19 / Background: Chagas disease is a public health and social problem in Latin America due to its high incidence, morbidity and mortality. Chagas cardiomyopathy is manifested mainly by sudden cardiac death, chronic systolic heart failure, thromboembolism, ventricular arrhythmias and advanced atrioventricular block. The right ventricular pacing is a common treatment modality in patients with chronic systolic heart failure secondary to Chagas cardiomyopathy with advanced atrioventricular block. However, it is unknown if the clinical course or the prognosis of patients with right ventricular pacing is worse than that seen in non-paced patients. Aim: Establish the role of permanent pacemaker implantation on the prognosis of patients with Chagas disease heart failure. Methods: All patients with chronic systolic heart failure secondary to Chagas cardiomyopathy followed at our institution between January 2000 and December 2008 were considered for the study. A model of Cox proportional hazards regression was used to determine the role of right ventricular pacing as an independent predictor of all-cause mortality in this population. The Kaplan-Meier curves were constructed to estimate the probability of survival in patients with and without right ventricular pacing, which were compared by the log rank test. Results: A total of 216 patients were enrolled; 116 (55%) were not treated with right ventricular pacing, but 100 (45%) patients were paced. One hundred and ten (51%) patients died during the study. No difference was observed in the mortality rate in paced (54%) in comparison to non-paced (56%) (p = 0.24). Pacemaker therapy for ventricular pacing was not a predictor of all-cause mortality in either univariate or multivariate analysis. Median follow-up was 19 (8, 43) months. However / Introdução: A doença de Chagas é um grave problema de saúde pública e social em países da América Latina devido a sua alta incidência, morbidade e mortalidade. A cardiomiopatia chagásica manifesta-se principalmente por morte súbita cardíaca, insuficiência cardíaca crônica sistólica, tromboembolismo, arritmias ventriculares e bloqueio atrioventricular avançado. A estimulação ventricular direita, através do implante de marcapasso unicameral, é uma modalidade de tratamento frequente em pacientes com insuficiência cardíaca crônica sistólica secundária à cardiomiopatia chagásica, que apresentam bloqueio atrioventricular avançado. No entanto, não se sabe a estimulação cardíaca em ventrículo direito, a longo prazo, teria efeitos maléficos sobre a função cardíaca desses pacientes. Objetivo: Avaliar o efeito do implante de marcapasso definitivo com estimulação ventricular direita no prognóstico de pacientes com Insuficiência Cardíaca Crônica Sistólica secundária à cardiomiopatia Chagásica. Métodos: Todos os pacientes com insuficiência cardíaca crônica secundária a cardiomiopatia chagásica seguido em nossa instituição entre janeiro de 2000 a dezembro de 2008 foram considerados para o estudo. Um modelo de riscos proporcionais de Cox foi utilizado para determinar o papel da estimulação elétrica ventricular direita como um fator de predição independente de mortalidade geral para esta população. As curvas de Kaplan-Meier foram construídas para estimar a probabilidade de sobrevida em pacientes com e sem marcapasso cardíaco de estimulação ventricular direita, que foram comparadas pelo teste de log rank. Resultados: Um total de 216 pacientes foram incluídos no estudo, 116 (55%) não possuíam marcapasso cardíaco artificial implantado, e 100 (45%) eram portadores de marcapasso cardíaco artificial. Cento e dez (51%) pacientes foram a óbito durante o estudo; não houve diferença significativa na taxa de óbito entre pacientes portadores (54%) e não portadores (56%) de marcapasso cardíaco artificial (p=0,24). A terapia com marcapasso definitivo de estimulação ventricular direita não foi um preditor de mortalidade geral e nem de hospitalização, quer na análise univariada ou na multivariada. A mediana de acompanhamento foi de 19 (8, 43) meses. Porém o tratamento com digoxina, o não tratamento com betabloqueadores e a concentração de sódio plasmático igual ou menor que 140mEq/L foram preditores independentes de mortalidade tanto na univariada como na multivariada (p<0,005). O tempo médio de uso de marcapasso foi de 54 ± 51 meses. Probabilidade de sobrevida aos 12, 24, 36 e 48 meses foi de 84%, 67%, 58% e 46%, respectivamente, em pacientes com marcapasso, e 94%, 85%, 80% e 74%, respectivamente, em pacientes sem marcapasso (p>0,05). Conclusão: A estimulação do ventrículo direito não é um preditor independente de mortalidade geral em pacientes com cardiomiopatia chagásica com insuficiência cardíaca crônica sistólica.

Page generated in 0.0657 seconds