• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 50
  • 43
  • 13
  • 12
  • 8
  • 7
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 157
  • 49
  • 44
  • 32
  • 32
  • 24
  • 23
  • 16
  • 15
  • 14
  • 14
  • 14
  • 13
  • 13
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Factors influencing health-related quality of life in patients with implantable cardioverter defibrillator. / CUHK electronic theses & dissertations collection

January 2013 (has links)
Wong, Mei Fung Florence. / Thesis (D.Nurs.)--Chinese University of Hong Kong, 2013. / Includes bibliographical references (leaves 178-208). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstract also in Chinese.
142

Estudo clínico randomizado para avaliação da segurança e dos efeitos da estimulação ventricular esquerda unifocal em pacientes com bradiarritmias / Randomized clinical trial for eficaccy, safety and performance of of isoleted left ventricular pacing in patients with bradyarrhythmias

Elizabeth Sartori Crevelari 31 August 2018 (has links)
Introdução: Considerando-se os potenciais efeitos deletérios da estimulação do ventrículo direito (VD), a hipótese desse estudo é que a estimulação unifocal ventricular esquerda (VE) pelo seio coronário é segura e pode proporcionar melhores benefícios clínicos e ecocardiográficos aos pacientes com bloqueio atrioventricular e função ventricular esquerda preservada ou pouco alterada, necessitando apenas da correção da frequência cardíaca. Objetivos: Avaliar a segurança, a eficácia e os efeitos da estimulação ventricular esquerda, utilizando um cabo-eletrodo com fixação ativa, em comparação à estimulação ventricular direita em pacientes com indicação de marca-passo (MP) convencional e função ventricular esquerda normal a moderadamente alterada. Métodos: Trata-se de um estudo clínico, randomizado, simples-cego que incluiu pacientes adultos com indicação de MP convencional por bloqueio atrioventricular avançado e função ventricular sistólica >= 0,40. A randomização aleatória (VD vs. VE) ocorreu antes do procedimento. Os desfechos primários do estudo foram o sucesso, a segurança e a eficácia do procedimento proposto. Os desfechos secundários foram a evolução clínica e alterações ecocardiográficas. Foram empregados os testes qui-quadrado, exato de Fisher e teste t de Student para comparação dos desfechos entre os dois grupos, considerando o nível de significância de 5%. Resultados: De junho de 2012 a janeiro de 2014 foram incluídos 91 pacientes, sendo 36 no grupo VD e 55 no grupo VE. As características basais dos pacientes dos dois grupos foram similares (P = NS). O implante de MP foi realizado com sucesso e sem nenhuma intercorrência em todos os pacientes do grupo VD. No grupo VE, entretanto, dos 55 pacientes inicialmente alocados, o implante do cabo-eletrodo em veias coronárias não foi possível em 20 (36,4%) pacientes. Complicações pós-operatórias foram detectadas apenas no grupo VE. A complicação mais frequente foi a estimulação frênica, detectada em 9 (25,7%) pacientes. Durante o período de seguimento do estudo, não houve hospitalizações por insuficiência cardíaca. Reduções superiores a 10% na fração de ejeção do ventrículo esquerdo foram observadas em 23,5% dos pacientes do grupo VD e em 20,6% dos do grupo VE (P = 0,767). A análise feita pelo Doppler tecidual mostrou que 55,9% dos indivíduos do grupo VD e 43,8% dos do grupo VE apresentaram dissincronia intraventricular ventricular esquerda (P = 0,324). Pelo mesmo método, foi detectado que 91,2% e 68,8% dos pacientes dos grupos VD e VE, respectivamente, apresentavam dissincronia interventricular (P=0,022). Conclusões: A estimulação ventricular esquerda exclusiva, nas condições estudadas, mostrou taxa de sucesso, segurança e eficácia inadequadas. A despeito da melhor sincronia interventricular observada nos pacientes sob estimulação ventricular esquerda, a comparação dos desfechos secundários entre os dois grupos não mostrou diferenças significativas / Background: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring only the correction of heart rate. Objective: To assess the safety, efficacy and effects of LV pacing using an active-fixation coronary sinus lead compared to RV pacing in patients eligible to conventional pacemaker (PM) implantation. Methods: Randomized, controlled and single-blinded trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function >= 0.40. Randomization (RV vs LV) occurred before PM implantation. Procedural success, safety, and efficacy were the main endpoints. Secondary outcomes were clinical and echocardiographic changes. Chi-square, Fisher\'s exact test and Student\'s t test were used, considering a significance level of 5%. Results: From June/2012 to January/2014, 91 patients were included, 36 in the RV group and 55 in the LV group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated to the LV group, the implant of the active-fixation coronary sinus lead was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations for heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and in 20.6% of those in the LV group (P= 0.767). Echo-tissue doppler showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (P= 0.022). Conclusion: Isolated left ventricular pacing, under the conditions studied, showed an inadequate success rate, safety and efficacy. Despite the better interventricular synchrony observed in LV group, the comparison of secondary outcomes between the two groups did not show significant differences
143

Estudo prospectivo e randomizado de profilaxia antimicrobiana para procedimentos cirúrgicos em estimulação cardíaca artificial / Prospective and randomized trial of antibiotic prophylaxis for cardiac stimulation surgical procedures

Oliveira, Júlio César de 11 September 2007 (has links)
O objetivo desse estudo foi avaliar os efeitos da administração prévia de antibiótico na incidência de complicações infecciosas em procedimentos de estimulação cardíaca artificial. Os pacientes foram selecionados em um estudo duplo-cego e randomizado (1:1). Grupo I Cefazolina (1,0g dose única) versus grupo II placebo. O comitê de segurança interrompeu o estudo após a inclusão de 649 pacientes devido à diferença entre os grupos (group I 314; grupo II 335 pacientes) em favor do uso de antibiótico: 2 infectados (0,63%) versus 11 infectados no grupo placebo (3,28%); p=0,016. Marcadores identificados por análise univariada: não uso de antibiótico; procedimentos de implantes (versus trocas); hematoma pós-operatório e duração do procedimento. O não uso de antibiótico e hematoma pós-operatório foram significantes em análise multivariada / The objective of this study was to evaluate the effects of the previous venous antibiotic administration in the incidence of infectious complications in cardiac stimulation surgical procedures. Patients were selected in a double blind, randomized (1:1) trial. Group I Cefazolin (1,0g one dose) versus group II placebo. The security committee interrupted the trial after inclusion of 649 patients due to differences between groups (group I 314; group II 335 patients) in favor of the antibiotic arm: 2 infected patients (0,63%) versus 11 infected patients in the placebo arm (3,28%); p=0,016. Markers identified by univariate analysis: non-use of preventive antibiotic; implant procedures (versus replacement); post-operative haematoma and procedure duration. The non-use of antibiotic and the post-operative haematoma were independent predictors of infection in multivariate analysis
144

Possible Influences of Circadian Melatonin on the Function of Neurosecretory Neurons and Serotonin-Modulated Behavior on Crayfish. / Mögliche Wirkungen von zirkadianische Melatonin in der Funktion der neurosekretorische Neuronen und Serotonin modulierte Verhaltens in Flusskrebse

Farca Luna, Abud Jose 17 October 2008 (has links)
No description available.
145

Zeitwahrnehmung in isochronen Sequenzen / Ein Vergleich verschiedener Modelle zum Einfluss des Kontextes auf die Wahrnehmungsleistung / Time perception in isochronous sequences / Comparing different models and their predictions on the influence of context on discrimination performance

Blaschke, Stefan 14 July 2009 (has links)
No description available.
146

Conception d’une tête radiofréquence auto adaptative au milieu de propagation pour les applications médicales

Chan wai po, Francis 23 July 2010 (has links)
L'impédance d'entrée d'une antenne miniature est fortement affectée par des facteurs environnementaux à l'origine de pertes de puissance réduisant l'efficacité énergétique des têtes radiofréquences dans les applications RF, en particulier dans la télémétrie des implants cardiaques. Le but de mes études est de développer une unité de calibration d'impédance d'antenne très faible consommation capable d'adapter toute variation de l'impédance d'entrée de l'antenne à l'impédance de la source radiofréquence. La première partie de mon étude est axée sur la conception au niveau système d'une approche nouvelle de calibration automatique du système. Un réseau d'adaptation automatique d'impédance sans coupleur et fonctionnant de façon directe est étudié et permet d'optimiser la taille du dispositif, la vitesse de l'adaptation, la consommation d'énergie et les performances globales. Deuxièmement, une nouvelle méthode de synthèse du réseau d'adaptation variable est proposée pour réduire fortement la complexité globale de l'algorithme d'adaptation. La troisième partie de mon étude est axée sur la fabrication d'un démonstrateur hybride fonctionnant dans la bande médicale MICS afin de valider le concept auto adaptatif d'impédance. Un banc expérimental qui comprend une antenne immergée dans son milieu connectée au démonstrateur piloté par un microcontrôleur a été mis en place et a permis d'atteindre un coefficient de réflexion jusqu'à -30dB avec un temps de calibration inférieur à 1ms. La dernière partie de mon travail consiste à concevoir le circuit d'adaptation automatique d'impédance d'antenne très faible consommation fonctionnant dans la bande ISM 2.4GHz en utilisant la technologie CMOS 0.13um. / Antenna input impedance is highly affected by environmental factors increasing the losses or reducing the power efficiency of the radiofrequency transceiver in many RF applications such as in implantable pacemaker device telemetry. The purpose of my study is to develop a low power fully integrated antenna-impedance tuning unit to match any variation of the antenna impedance to the source. The first part of my study is focused on the system-level design of a new approach to automatically match the system. A couplerless single step automatic matching network is investigated to optimize the die size, the speed, the power consumption and the overall performance. Second, a new method for synthesizing an automatic matching network is developed reducing strongly the overall complexity of the matching algorithm. The third part of my study is focused on the fabrication of a hybrid demonstrator operating at the Medical Implantable Communication Service (MICS) frequency band to validate the concept. An experimental set-up including the antenna tuning unit, a microcontroller and a pacemaker antenna connected to the demonstrator was done achieving a reflection coefficient up to -30dB, an overall tuning time less than 1ms. The last part of my work is to design the entire automatic matching network circuit in 0.13um CMOS technology including a front-end transceiver designed under ultra low power constraints and operating at 2.4GHz ISM frequency band. The additional items overall power consumption is less than 1.5mW under 1.2V supply voltage.
147

Estudo prospectivo e randomizado de profilaxia antimicrobiana para procedimentos cirúrgicos em estimulação cardíaca artificial / Prospective and randomized trial of antibiotic prophylaxis for cardiac stimulation surgical procedures

Júlio César de Oliveira 11 September 2007 (has links)
O objetivo desse estudo foi avaliar os efeitos da administração prévia de antibiótico na incidência de complicações infecciosas em procedimentos de estimulação cardíaca artificial. Os pacientes foram selecionados em um estudo duplo-cego e randomizado (1:1). Grupo I Cefazolina (1,0g dose única) versus grupo II placebo. O comitê de segurança interrompeu o estudo após a inclusão de 649 pacientes devido à diferença entre os grupos (group I 314; grupo II 335 pacientes) em favor do uso de antibiótico: 2 infectados (0,63%) versus 11 infectados no grupo placebo (3,28%); p=0,016. Marcadores identificados por análise univariada: não uso de antibiótico; procedimentos de implantes (versus trocas); hematoma pós-operatório e duração do procedimento. O não uso de antibiótico e hematoma pós-operatório foram significantes em análise multivariada / The objective of this study was to evaluate the effects of the previous venous antibiotic administration in the incidence of infectious complications in cardiac stimulation surgical procedures. Patients were selected in a double blind, randomized (1:1) trial. Group I Cefazolin (1,0g one dose) versus group II placebo. The security committee interrupted the trial after inclusion of 649 patients due to differences between groups (group I 314; group II 335 patients) in favor of the antibiotic arm: 2 infected patients (0,63%) versus 11 infected patients in the placebo arm (3,28%); p=0,016. Markers identified by univariate analysis: non-use of preventive antibiotic; implant procedures (versus replacement); post-operative haematoma and procedure duration. The non-use of antibiotic and the post-operative haematoma were independent predictors of infection in multivariate analysis
148

Desenvolvimento de modelos preditores de óbito cardíaco na terapia de ressincronização / Development of predictive models of cardiac mortality in resynchronization therapy

Eduardo Arrais Rocha 28 February 2014 (has links)
Introdução: A terapia de ressincronização cardíaca (TRC) é um tratamento recomendado pelas principais diretrizes mundiais para pacientes com insuficiência cardíaca congestiva (ICC), disfunção ventricular esquerda (FE <= 35%), com tratamento otimizado e distúrbio da condução intraventricular, principalmente pelo ramo esquerdo. Entretanto, 30%-40% dos pacientes selecionados não respondem ao tratamento. As razões desse insucesso não são completamente conhecidas. Existe, portanto, necessidade de desenvolvimento de índices multifatoriais para melhor selecionar e acompanhar a evolução e o prognóstico destes pacientes. Objetivo: Elaborar modelos preditores de risco de óbito cardíaco ou transplante (Tx), em diferentes fases da TRC. Métodos e Casuística: Estudo observacional, prospectivo e analítico, com inclusão de 116 pacientes, entre 01/2008 a 03/2013, sendo 69,8% do sexo masculino, com CF III (68,1%) e IV ambulatorial (31,9%), com BRE em 71,55% e com idade de 64,89 ± 11,18 anos e fração de ejeção (FE) de 29%. Avaliações foram feitas no período pré-implante (tempo 1), 6-12 meses (tempo 2) e 18-24 meses (tempo 3) e correlacionadas com a mortalidade cardíaca/Tx no final do seguimento. Foram estudadas variáveis clínicas, eletrocardiográficas e ecocardiográficas e realizadas análises de regressão de Cox e regressão logística, com a construção da curva ROC. As curvas de sobrevidas foram realizadas pelo método de Kaplan-Meier e comparadas pelo log-rank. Modelos e escores foram elaborados pelas pontuações do \"hazard ratio\", utilizado como variável independente no modelo de regressão logística. Resultados: Ocorreram 29 (25%) óbitos/Tx durante o seguimento de 34,09 ± 17,9 meses. A mortalidade cardíaca/Tx foi de 16,3 % (19 pacientes). Seis pacientes foram transplantados durante o tempo do estudo. No período préimplante (tempo 1), a presença de disfunção de ventrículo direito (VD), FE < 25% e o uso de altas doses de diuréticos (dois ou mais comprimidos de furosemida) mostraram-se com valor independente, com aumento de risco de óbito cardíaco/Tx de 3,9; 4,8 e 5,9 vezes, respectivamente. No tempo 2 (1° ano), as variáveis disfunção de VD, altas doses de diuréticos e internações por ICC foram as variáveis significativas, com aumento de risco 3,5; 5,3 e 12,5 respectivamente. No tempo 3 (2° ano), as variáveis disfunção de VD e classe funcional III/IV foram significativas no modelo multivariado de Cox, com aumento de risco de 12,1 e 7,7. As acurácias dos modelos foram 84,6%; 93% e 90,5%, respectivamente. Conclusão: Os modelos preditores de óbito cardíaco desenvolvidos a partir de variáveis clínicas e ecocardiográficas, obtidas em diferentes fases da TRC, mostraram boa acurácia e podem ajudar na seleção, seguimento, definição de resposta e aconselhamento destes pacientes / Introduction: Cardiac resynchronization therapy (CRT) is indicated for patients with congestive heart failure (CHF), ejection fraction (EF) <= 35%, and bundle branch block. However, 30%-40% do not respond to CRT. Therefore, there is a need to develop multifactorial indexes to better select and follow these patients. Objective: This work aims to develop predictive models for the risk of cardiac death or transplantation (Tx) at different stages of CRT. Methods: We performed a prospective observational study of 116 patients, 69.8% males, functional class (FC) III (68.1%) and IV (31.9%), LBBB in 71.55%, age 64.89 ± 11.18 years. We studied clinical, electrocardiographic, and echocardiographic variables and performed Cox and logistic regression with ROC and Kaplan- Meier curves. Results: The cardiac mortality was 16.3% (19 patients) in the 34.09 ± 17.9 follow-up months. Pre-implantation, the right ventricular dysfunction (RVD), EF <25%, and the use of high doses of diuretics (HDD) increased risk of cardiac death or Tx of 3.9, 4.8, and 5.9 fold, respectively, and in the first year, the variables RVD, HDD, and hospitalizations for CHF increased risk of death of 3.5, 5.3, and 12.5, respectively. In the 2nd year, the variables RVD and FC III / IV (NYHA) were significant in the multivariate Cox model. The accuracies of the models were 84.6%, 93%, and 90.5%, respectively. Conclusions: Cardiac death predictive models were developed in different stages of CRT, and were based on the analysis of simple clinical and echocardiographic variables. The models showed good accuracy and can help in the selection and follow-up of these patients
149

"Cardiomiopatia hipertrófica: importância dos eventos arrítmicos em pacientes com risco de morte súbita" / Hypertrophic cardiomyopathy: sudden cardiac death in high risk patients and the role of arrhythmias

Paulo de Tarso Jorge Medeiros 10 December 2004 (has links)
Vinte e seis pacientes com cardiomiopatia hipertrófica e fatores de risco de morte súbita, foram submetidos a implante de cardioversor-desfibrilador implantável de dupla-câmara, com seguimento médio de 19 meses. Observou-se quatro choques em arritmias letais, 4 pacientes apresentaram TVNS e 5 taquiarritmias supraventriculares. Ocorreu um óbito.Conclusões: Observamos: TPSV em 19,2%; TVNS em 15,4% e TVS/FV em 15,4%. Nenhuma variável clínica ou demográfica, discriminou o comportamento clínico ou funcional pós-implante de CDI; a recorrência de síncope pós implante de CDI, não se associou à presença de eventos arrítmicos e a hipertrofia maior que 30 mm se associou à choque precoce do CDI (p=0,003). / During 19 months of average follow-up period, we followed 26 patients with hypertrophic cardiomyopathy and high risk for sudden death, all treated by dual chamber implantable cardioverter-defibrillator. 4 patients had received appropriate ICD discharge, 4 patients with NSVT and 5 supraventricular arrhythmias. One death had occurred. Conclusions: we observed: supraventricular arrhythmias in 19,2%; NSVT in 15,4% and VT/VF in 15,4%. The clinical or demographic outcomes did not suggest any clinical or functional results after ICD implantation; syncope may occur after ICD implantation and no arrhythmias recordered by intracardiac electrograms and left-ventricular-wall thickness greater than 30 mm is associated with early ICD shocks (p=0,003).
150

Přístroje EMD a jejich ovlivnění / EMD instruments and electromagnetic mmunity

Mikula, Dalibor January 2009 (has links)
The work deals with implantable devices and possibilities of interference of elektromagnetic field. At first, the electromagnetic compatibility is discussed. Basic terms are explained, followed by insisting on resources of possible distrurbing of implantable devices and standards dealing with this issue. Furthermore, short chapter about devices affecting function of implantable devices is introduced. It means devices which patients with implantable devices may meet in common life, as well as devices used in common life, also devices used jn medical environment. In the next part, measuring process of electromamagnetic effect in working compartment of FN Brno magnetotheraphy and elektrotheraphy is devised. There is a concept of measuring card thanks to which impulses of implantable devices are measured. Finally, a description of measuring on implantable devices in FN Brno. MIKULA, D. EMD instruments and electromagnetic immunity. Brno, 2009. 74 s. Master’s thesis in Brno University of technology on faculty of elektrical engeenerig and communication. Supervisor Ing. Marie Havlíková , Ph.D.

Page generated in 0.0463 seconds