841 |
Desenvolvimento de eletrodos de carbono vítreo modificados com nanotubos de carbono funcionalizados imobilizados em filmes de hidrocloreto de poli(alilamina) para determinação de fármacos / Abstract development of a glass carbon electrode modified with functionalized carbon nanotubes immobilized in hydrochloride poly (allylamine) films for pharmaceuticals determinationTakeda, Humberto Hissashi 18 February 2011 (has links)
Made available in DSpace on 2016-06-02T20:34:26Z (GMT). No. of bitstreams: 1
3714.pdf: 1474350 bytes, checksum: 3415e17a9bd54c929733f858dcef7c2f (MD5)
Previous issue date: 2011-02-18 / Universidade Federal de Sao Carlos / Research involving carbon nanotubes (CNT) have a great attraction since its synthesis to the technology application. As part of the work was studied the formation and the stability of a functionalized Multiwall Carbon Nanotubes (MWCNTs) dispersion in a hydrochloride poly(allylamine) (PAH) polyelectrolyte solution 1.2 x 10-4 mol L-1 (MWCNTs/PAH) in order to use it for surface modification of a glassy carbon electrodes (GCE) by casting technique. Zeta potential measurements confirmed the stability of the MWCNTs/PAH dispersion. After this study were carried out modifications of GCE surfaces with the MWCNTs/PAH (GCE-MWCNTs/PAH) dispersion and found the electrochemical behavior of the film formed by cyclic voltammetry with potassium hexacyano ferrate (III) 6,6 x 10-4 mol L-1 in a potassium chloride solution 0, 1 mol L-1. The results proved the electrochemical effect provided by the MWCNTs and with the Randles-Sevcik equation we have obtained an active area for GCE-MWCNTs/PAH 1.2 times higher compared to the GCE bare. For further study, we evaluated the GCE-MWCNTs/PAH performance in a pharmaceuticals formulations with voltammetric and amperometric determinations, ciprofibrate, dopamine (DA), levodope (L-dopa) and carbidope. The ciprofibrate determination were measured by differential pulse voltammetry (DPV) and was used as supporting electrolyte a solution of sodium phosphate buffer 0.1 mol L-1 (pH 7,0). The analytical curve was linear in the ciprofibrate concentration range from 1.33 x 10-5 to 1.32 x 10-4 mol L-1 with a detection limit of 8.34 x 10-6 mol L-1. For DA determination was measured by amperometric measurement in a potential of 0.2 V in a phosphate buffer solution 0.1 mol L-1 (pH 7.0) as supporting electrolyte, and the analytical curve showed a linearity over the concentration range between 3.32 x 10-6 to 3.32 x 10-5 mol L-1 with a detection limit of 5.7 x 10-7 mol L-1. The L-dopa determination was done with the DPV and was used as a supporting electrolyte a sodium chloride solution (NaCl) 0.1 mol L-1. The analytical curve obtained showed a linearity over the concentration range of 2.00 x 10-6 to 2.72 x 10-5 mol L-1 and the limit of detection was 8.4 x 10-7 mol L-1. The carbidopa determination were measured by DPV and was used as a supporting electrolyte a NaCl solution 0.1 mol L-1 and the analytical curve xv showed a linearity over the concentration range of 2.00 x 10-6 to 2.34 x 10-5 mol L-1 and detection limit obtained was 6.50 x 10-7 mol L-1. / Pesquisas envolvendo nanotubos de carbono (NTC) apresentam um grande atrativo desde a sua síntese até a aplicação tecnológica. Como parte do trabalho foi estudado a formação e a estabilidade de uma dispersão de nanotubos de carbono de paredes múltiplas (MWCNTs) funcionalizados em uma solução do polieletrólito hidrocloreto de poli(alilamina) (PAH) 1,2 x 10-4 mol L-1 (MWCNTs/PAH) a fim de se utilizá-la para a formação de filmes fabricados pela técnica de casting para modificação da superfície de eletrodos de carbono vítreo (GCE). Medidas de potencial zeta comprovaram a estabilidade da dispersão MWCNTs/PAH. Após este estudo foram realizadas as modificações das superfícies dos GCE (GCEMWCNTs/ PAH) e verificou-se o comportamento eletroquímico do filme formado com medidas de voltametria cíclica em presença de hexacianoferrato(III) de potássio (K3[FeCN]6) 6,6 x 10-4 mol L-1 em cloreto de potássio 0,1 mol L-1. Os resultados obtidos comprovaram o efeito eletroquímico proporcionado pelos MWCNTs e com a equação de Randles-Sevcik obteve-se uma área ativa para o GCE-MWCNTs/PAH 1,2 vezes maior em relação ao GCE não modificado. Para a continuação do trabalho, foi avaliado o desempenho do GCE-MWCNTs/PAH em determinações voltamétricas e amperométricas dos fármacos, ciprofibrato, dopamina (DA), levodopa (L-dopa) e carbidopa. Para a determinação do Ciprofibrato foram realizadas medidas de Voltametria de Pulso Diferencial (DPV) e como eletrólito suporte foi utilizada uma solução de tampão fosfato 0,1 mol L-1 (pH 7,0). A curva analítica obtida apresentou uma linearidade no intervalo de concentração de 1,33 X 10-5 a 1,32 X 10-4 mol L-1 com um limite de detecção de 8,34 x 10-6 mol L-1. Para a determinação de DA foram realizadas medidas amperométricas em um potencial de 0,2 V, e a curva analítica obtida apresentou uma linearidade no intervalo de concentração entre 3,32 x 10-6 a 3,32 x 10-5 mol L-1 com um limite de detecção de 5,7 x 10-7 mol L-1. A determinação de L-dopa foi realizada com medidas de DPV e como eletrólito suporte foi utilizado uma solução de cloreto de sódio (NaCl) 0,1 mol L-1. A curva analítica obtida apresentou uma linearidade no intervalo de concentração de 2,00 x 10-6 a 2,72 x 10-5 mol L-1 e o limite de detecção encontrado foi de 8,4 x 10-7 mol L-1. Para a xiii determinação de carbidopa foram realizadas medidas de DPV e como eletrólito suporte foi utilizada uma solução de NaCl 0,1 mol L-1 e a curva analítica obtida apresentou uma linearidade no intervalo de concentração de 2,00 x 10-6 a 2,34 x 10-5 mol L-1 e o limite de detecção obtido foi de 6,50 x 10-7 mol L-1. xiv
|
842 |
Desenvolvimento de procedimentos de digestão e especiação para amostras biológicas / Development of digestion procedures and fractionation for biological samplesMatos, Wladiana Oliveira 29 April 2011 (has links)
Made available in DSpace on 2016-06-02T20:34:27Z (GMT). No. of bitstreams: 1
3805.pdf: 1044175 bytes, checksum: 56716ff3ec41f7429ef7073be8b2d3e5 (MD5)
Previous issue date: 2011-04-29 / Financiadora de Estudos e Projetos / In general, sample preparation is the most critical step in an analytical sequence. The development of faster, simpler, cheaper and greener procedures is required. In this work, two digestion methods for biological samples using microwave radiation have been developed. One of proposed digestion methods consist on the partial decomposition of meat tissues using PTFE micro vessels under microwave radiation. In this procedure, it was used 50 mg of sample and 50 μL of concentrated HNO3. Digestion is carried out in 7 min applying 650 W microwave power. Recoveries around 100% were obtained for determination of Ca, Cu, Fe, Mg, Mn and Zn by ICP OES, when the method was applied to bovine liver and muscle certified reference materials. The second proposed digestion method combines the use of infrared radiation with microwave radiation, which allowed the decomposition of 1 g of human food and coffee samples by using microwave oven cavity. Recoveries around 80-100% were reached in the determination of Al, Ca, Cu, Fe, Mg, Mn and Zn by ICP OES in certified reference materials. Another part of the thesis work was dedicated to the study of selenium fractionation and identification of its organic and inorganic species in samples of bovine semen. Selenium presents essential role in several biological functions of mammals. Infertility in humans and animals, including bulls, is related to the lack of this element. In this context, selenium distribution in lipids, proteins and low molecular weight compounds fractions of bovine semen was evaluated. Besides, a chromatographic separation method for Se(IV), Se(VI) and selenomethionine methylselenocysteine species was developed, in order to identify these species in a semen bovine sample. / Em geral, a etapa de preparo de amostras é a mais crítica em uma sequência analítica. O desenvolvimento de procedimentos de preparo rápidos, simples, de baixo custo e que produzam menos resíduos é necessário. Nesse trabalho foram desenvolvidos dois métodos de digestão para amostras biológicas empregando radiação microondas. Um dos métodos de digestão proposto consiste na decomposição parcial de amostras de carne assistida por radiação micro-ondas usando minifrascos de PTFE. Nesse procedimento, empregaram-se 50 mg de amostra e 50 μL de HNO3 concentrado. A digestão é feita em 7 min, aplicando-se potência de 650 W. Recuperações na faixa de 95-109% foram obtidas para Ca, Cu, Fe, Mg, Mn e Zn determinados por ICP OES, quando o método foi aplicado em materiais de referência certificado de fígado e músculo bovino. O segundo método de digestão proposto combina o uso da radiação infravermelha à radiação microondas, o que permite a decomposição de 1 g de amostras de café e ração humana em forno de micro-ondas com cavidade. Recuperações na faixa de 80-100% foram obtidas para Al, Ca, Cu, Fe, Mg, Mn e Zn determinados por ICP OES em material de referência certificado. Outra parte do trabalho da tese foi dedicada ao estudo do fracionamento de selênio e identificação de espécies orgânicas e inorgânicas desse elemento em amostras de sêmen de bovinos. O selênio apresenta papel essencial em diversas funções de animais mamíferos. A infertilidade de humanos e animais, incluindo bovinos, está relacionada à carência desse elemento. Nesse contexto, realizou-se o estudo da distribuição de selênio nas fases lipídica, proteica e de compostos de baixo peso molecular em sêmen de bovinos. Desenvolveu-se método de separação cromatográfica Se(IV), Se(VI), metilselenocisteína e selenometionina, a fim de identificar essas espécies em amostra de sêmen bovino.
|
843 |
Estratégias analíticas para a avaliação química de solos e liquens da Antártica marítima / Analytical strategies for the chemical analysis of soils and lichens from Maritime AntarcticaGuerra, Marcelo Braga Bueno 12 August 2011 (has links)
Made available in DSpace on 2016-06-02T20:34:28Z (GMT). No. of bitstreams: 1
3893.pdf: 1757499 bytes, checksum: 3bbc6d0e9ef4dbd1c8f3915592d4ee2b (MD5)
Previous issue date: 2011-08-12 / Universidade Federal de Minas Gerais / The aim of this PhD thesis is the ample study of soil and lichen samples from Antarctica, collected in regions under strong anthropogenic impact. Surface soil samples were collected around several scientific stations: Brazilian (Comandante Ferraz), Argentinian (Esperanza), Chilean (Frei Montalva and Escudero), Chinese (Great Wall), Russian (Bellingshausen) and Uruguaian (Artigas). Control soil samples were also collected, for representing areas with low anthropic influence (far away from the local stations). Lichen samples (Usnea antarctica and Usnea aurantiacoatra) were collected near the Chilean and Russian stations, as well as in a control point far 0.5 km from the nearest station. X-ray Fluorescence was used as an analytical tool for the preliminary evaluation on metal contamination in the soil samples. Several extraction solutions (aqua regia, sequential extraction procedure, DTPA and CaCl2 solutions) were used to assess the amounts of metals in the soil samples. For Cd, Cr, Cu, Mn, Ni, Pb and Zn determination in the soil extracts, some analytical strategies were employed, such as fast sequential determination by FAAS in the conventional mode, as well as by using STAT-FAAS and TS-FF-AAS for evaluating Cd and Pb determination in DTPA soil extracts. The chemometric tools: HCA, PCA and PARAFAC were used for soil data treatment. Enrichment factors were calculated in order to infer about the degree of soil contamination. Soil samples collected around the stations diesel tanks were enriched with Cr and Pb. Soil samples from Esperanza station are the most contaminated ones, reaching 46, 18993 and 4823 mg kg-1 for Cd, Pb and Zn, respectively, for the strongest contaminated sites. The use of Flame-AAS and STAT-FAAS in the fast sequential mode appears as a good way that combines higher analytical throughput and better sensitivity (STAT-FAAS). Besides that, minimization of toxic wastes generation and xv economy of reagents are analytical advantages of this approach. The employment of chemometric tools are also an important strategy allowing the visualization of sample groupings and the variables related to them. A fast and simple method for pseudototal determination of metals in soil samples was developed. In this method, the samples were extracted with lower amount of aqua regia and in a reduced time (when compared with the official method) by using inexpensive centrifuge tubes. LAICP- MS was evaluated for direct determination of lead in the lichen samples and to access the distribution profile of this element in the organism structures. Lichen samples from heavily anthropogenic sites (near the stations) have the highest Pb concentrations ([Pb] = 8.71 mg kg-1 for the most contaminated sample and [Pb] = 1.12 mg kg-1 for the control point). LA-ICP-MS emerges as an adequate analytical method for direct Pb determination in lichen samples, notably when using carbon (naturally present in the samples) as internal standard. The medulla region of the lichen thalli is the main Pb bioacumulating lichen region. / Esta tese de doutorado está centrada no estudo de amostras de solos e liquens provenientes da Antártica, coletadas em regiões submetidas a elevado impacto antrópico. Amostras de solos superficiais foram coletadas nas imediações de diversas estações de pesquisa da Antártica: estação brasileira (Comandante Ferraz), estação argentina (Esperanza), estações chilenas (Eduardo Frei Montalva e Escudero), estação chinesa (Great Wall), estação russa (Bellingshausen) e estação uruguaia (Artigas). Amostras de solos (referência) foram coletadas em locais pouco afetados por atividades humanas (distantes das estações). Amostras de liquens (Usnea antarctica e Usnea aurantiaco-atra) foram coletadas nas vizinhanças das estações chilenas e russa, assim como em um ponto controle distante pelo menos 0,5 km da estação mais próxima. A Fluorescência de raios-X foi utilizada como ferramenta analítica para a avaliação preliminar de contaminação por metais nas amostras de solos. Diversas soluções extratoras (água régia, procedimento de extração sequencial, DTPA e CaCl2) foram usadas para acessar diferentes estoques de metais nas amostras de solos. Para a determinação dos elementos Cd, Cr, Cu, Mn, Ni, Pb e Zn nos extratos das amostras de solos, várias estratégias analíticas foram empregadas como a determinação sequencial rápida destes elementos empregando a FAAS no modo convencional , assim como a STAT-FAAS. O TS-FFAAS foi avaliado para a determinação de Cd e Pb em extratos de solos usando DTPA como agente extrator. Devido à vasta quantidade de informação gerada pelas determinações analíticas das amostras de solos, algumas ferramentas quimiométricas foram empregadas como: HCA, PCA e PARAFAC. Fatores de enriquecimento foram calculados para verificar o grau de contaminação dos solos coletados no entorno das estações de pesquisa. Regiões próximas aos tanques de xiii óleo diesel das estações de pesquisa estudadas possuem sistematicamente elevadas concentrações de Cr e Pb, dentre os elementos investigados. As amostras de solos coletadas no entorno da estação Esperanza destacam-se como as mais intensamente contaminadas por todos os elementos potencialmente tóxicos determinados, exceto pelo Cr. Amostras de solos provenientes dos locais mais contaminados no entorno da estação Esperanza, exibem concentrações pseudototais médias de 46, 18993 e 4823 mg kg-1 para Cd, Pb e Zn, respectivamente. O uso da FAAS e STAT-FAAS no modo sequencial rápido permitiu aliar alta frequência analítica e ganho em sensibilidade (STAT-FAAS) além de minimizar a geração de resíduos tóxicos e propiciar economia de reagentes. O uso das ferramentas quimiométricas foi uma estratégia importante que permitiu a visualização de agrupamentos de amostras e a avaliação conjunta das variáveis responsáveis por estes agrupamentos. Foi proposto um método mais simples e rápido para a determinação da fração pseudotototal de metais nas amostras de solos. Neste método as amostras são extraídas com menor volume de água régia e por menor tempo (quando comparado com o método oficial) em tubos de centrífuga de 15 mL. A técnica LA-ICP-MS foi empregada para a determinação direta de Pb nas amostras de liquens assim como para construir bioimagens da distribuição deste elemento nos talos destes organismos simbiontes. As amostras de liquens coletadas nos pontos afetados pelas estações de pesquisa possuem concentrações de Pb mais elevadas ([Pb] = 8,71 mg kg-1 para o ponto mais contaminado) quando comparadas com o ponto controle ([Pb] = 1,12 mg kg-1). A técnica LA-ICP-MS mostrou-se como uma ferramenta viável para a determinação direta de Pb nas amostras de liquens, sobretudo ao se utilizar carbono como padrão interno. Além disso, essa técnica permitiu acessar o perfil de distribuição do Pb nas estruturas anatômicas dos liquens, mostrando que a região medular desses organismos é o local onde o elemento Pb se acumula preferencialmente.
|
844 |
Desenvolvimento de eletrodos modificados com polímeros condutores e nanotubos de carbono e aplicação na determinação de analitos de interesse farmacêutico em amostras biológicas e em fármacos / Development of modified electrodes with conducting polymers and carbon nanotubes to application in the determination of analytes of pharmaceutical interest in biological and drugs samplesTroiani, Estela de Pieri 15 July 2011 (has links)
Made available in DSpace on 2016-06-02T20:34:32Z (GMT). No. of bitstreams: 1
4083.pdf: 6687109 bytes, checksum: f781137de55353c7c7a938c76ed013e1 (MD5)
Previous issue date: 2011-07-15 / Universidade Federal de Sao Carlos / In this work is reported the studies carried out modified electrodes with poly(1-aminoanthracene) (PAA) and poly(1-aminoanthraquinone) (PAAQ), and composite films from a mixture of polymers with carbon nanotubes (CNTs). These electrodes were used for determination of dopamine (DA), ascorbic acid (AA) and uric acid (UA) in synthetic and real biological samples; in addition, we performed the determination of norepinephrine (NE) and hydroquinone (HQ) in pharmaceutical samples. In this context, was evaluated the influence of a cathodic pretreatment applied to the modified electrodes by verifying a change in electrochemical properties of the films so that after pretreatment of the PAA electrode showed electrocatalytic response to DA while the PAAQ electrode showed a significant increase in DA response. In this work, PAA and PAAQ films were electropolymerized on platinum electrodes, and their surfaces were characterized by microscopic techniques. PAA film showed DA response only after the cathodic pretreatment, which consisted of applying a potential of −0.7 V for 3 s prior to voltammetric measurements. It was found that the union of CNT, PAA and cathodic pretreatment provided a positive synergy, resolving the overlapping oxidation peaks of DA, AA and UA in three well defined peaks. For the PAAQ film, simultaneous responses of AA, DA and UA, with well-defined oxidation peaks was obtained after application of pretreatment, not requiring the incorporation of CNTs in polymer matrix. Using differential voltammetry, analytical curve for AA, DA and UA were constructed with the composite electrode PAACNT showed detection limits of 39.5, 0.29 e 42.2 μmol L−1, respectively. To the cathodically pretreated PAAQ electrode, detection limits obtained were 25.0, 3.05, e 11.5 μmol L−1 for AA, DA and UA, respectively. xxvi Addition of the CNTs in PAAQ film provided a small increase in DA detection limit in the ternary mixture AA, DA and UA, with a value of 3.23 μmol L−1. Following a procedure was developed for NE analysis, using the square wave voltammetry technique (SWV) and using modified PAA electrode. The analytical curve was linear over the NE concentration range between 2.18 99.6 μmol L−1, with a detection limit of 0.58 μmol L−1. Finally, a procedure was developed for the HQ determination using the modified PAAQ electrode and SWV technique. Under optimized experimental conditions, analytical curve was constructed, the HQ concentration obtained range between 2.97 25.5×10−5 mol L−1 and detection limit equal 2.11 μmol L−1. The proposed methods were applied in biological and pharmaceutical samples, obtaining satisfactory results. / Neste trabalho, são apresentados os estudos realizados com eletrodos modificados com filmes de poli(1-aminoantraceno) (PAA) e poli(1- aminoantraquinona) (PAAQ), bem como filmes compósitos polimerizados a partir da mistura destes polímeros com nanotubos de carbono (CNTs). Tais eletrodos foram utilizados para a determinação de dopamina (DA), ácido ascórbico (AA) e ácido úrico (AU) em amostras biológicas reais e sintéticas, além disso, foi realizada a determinação de norepinefrina (NE) e hidroquinona (HQ) em amostras farmacêuticas. Neste contexto, foi avaliada a influência de um pré-tratamento catódico aplicado nos eletrodos modificados verificando-se uma mudança nas propriedades eletroquímicas dos filmes de tal maneira que após o pré-tratamento o eletrodo de PAA apresentou resposta eletrocatalítica para DA enquanto que o eletrodo de PAAQ apresentou um aumento significativo na resposta para DA. Neste trabalho, os filmes de PAA e PAAQ foram eletropolimerizados sobre eletrodos de platina, sendo suas superfícies caracterizadas por técnicas microscópicas. O filme de PAA apresentou resposta para DA somente após o pré-tratamento catódico, que consistiu na aplicação de um potencial de −0,7 V durante 3 s antes das medidas voltamétricas. Verificouse que a união de CNTs, PAA e a aplicação do pré-tratamento catódico apresentou um efeito sinérgico resolvendo a sobreposição dos picos de oxidação de DA, AA e AU em três picos bem definidos. Para o filme de PAAQ, a resposta simultânea de AA, DA e AU, com picos de oxidação bem definidos, foi obtida após aplicação do pré-tratamento catódico, não sendo necessária a incorporação de CNTs na matriz polimérica. Utilizando a voltametria de pulso diferencial, curvas analíticas para AA, DA e AU foram construídas com o xxiv eletrodo PAACNT apresentando limites de detecção de 39,5; 0,29 e 42,2 μmol L−1, respectivamente. Para o eletrodo PAAQ pré-tratado catodicamente, os limites de detecção obtidos foram de 25,0; 3,05 e 11,5 μmol L−1 para AA, DA e AU, respectivamente. A adição de CNTs ao filme de PAAQ proporcionou um pequeno aumento no limite de detecção para DA contida na mistura ternária AA, DA e AU, com valor de 3,23 μmol L−1. Na sequência foi desenvolvido um procedimento para análise de NE, por meio da técnica de voltametria de onda quadrada (SWV) e utilizando-se um eletrodo modificado com filme de PAA. A curva analítica obtida foi linear no intervalo de concentração entre 2,18 99,6 μmol L−1, com limite de detecção de 0,58 μmol L−1. Por fim, foi desenvolvido um procedimento para a determinação de HQ utilizando o eletrodo modificado com PAAQ e SWV. Sob condições experimentais otimizadas, uma curva analítica foi construída, sendo apresentado um intervalo de concentração entre 2,97 25,5×10−5 mol L−1 e limite de detecção igual a 2,11 μmol L−1. Os métodos propostos foram aplicados em amostras biológicas e farmacêuticas, obtendo-se resultados satisfatórios.
|
845 |
Desenvolvimento de métodos para fracionamento de proteínas e metaloproteínas em carne bovina / Development of methods for fractionation of proteins and metalloproteins in beefCarapelli, Rodolfo 30 September 2011 (has links)
Made available in DSpace on 2016-06-02T20:34:33Z (GMT). No. of bitstreams: 1
4201.pdf: 1105695 bytes, checksum: 41c82e2e434b34f67fdaecb9396797d9 (MD5)
Previous issue date: 2011-09-30 / Universidade Federal de Sao Carlos / This thesis aimed the fractionation of metalloproteins in beef samples. To this purpose initially it was proposed a method for extraction of proteins using the sample extractor in buffered alkaline medium and surfactant solutions. After optimization were observed approximately 85% extraction efficiency and r.s.d. < 5%, showing the efficiency, reproducibility, simplicity and velocity of the method. After that, the experimental conditions for the fractionation of metalloproteins were evaluated. High performance liquid chromatography (HPLC) and polyacrylamide gel electrophoresis (PAGE) were used for physical-chemical separation and mass spectrometry and optical emission inductively coupled argon plasma (ICP OES and ICP-MS, respectively) as detection methods. The analytes Ca, Cu, Fe, Mg and Zn were evaluated; however, Mg was not detected in any condition of the study. To obtain a condition of appointment of detection for the other four elements, it was chosen to use less energy plasma conditions in ICP-MS (cool plasma), in order to avoid isobaric interference emanating from the plasma when the determination of the elements Ca and Fe. Finally, samples of meat with different maturation stages were analyzed by PAGE and HPLC-ICP-MS. Approximately 17 protein bands could be observed by PAGE and the band of 43 kDa was the more intense. Some peaks were detected for each element by HPLC size exclusion. All items showed at least a fraction above the dead volume of the column, Fe and Zn, and this fraction, also showed a fraction of 17 and 27 kDa respectively. / Esta tese teve como principal objetivo o fracionamento de metaloproteínas em amostras de carne bovina. Para isso, inicialmente foi proposto um método para extração de proteínas nas amostras de interesse utilizando extrator em meio alcalino tamponado e o emprego de surfactantes. Após otimização foram observados aproximadamente 85 % de eficiência de extração e d.p.r. < 5%, demonstrando ser eficiente e reprodutível, além de ser um método simples e rápido. A seguir foram avaliadas as condições experimentais de análise para o fracionamento das metaloproteínas. Foram empregadas cromatografia líquida de alta eficiência (HPLC) e a eletroforese em gel de poliacrilamida (PAGE) como técnicas físico-químicas de separação e espectrometria de massa e de emissão óptica com plasma de argônio indutivamente acoplado (ICP-MS e ICP OES, respectivamente) como métodos de detecção. Os analitos monitorados foram Ca, Cu, Fe, Mg e Zn, contudo, o Mg não foi detectado em nenhuma das condição estudadas. Para a obtenção de uma condição de compromisso de detecção para os outros 4 elementos, optou-se por utilizar condições de plasma menos energéticas em ICP-MS ( cool plasma), como forma de se evitar interferências isobáricas provindas do plasma quando da determinação dos elementos Ca e Fe. Por fim, amostras de carne com diferentes períodos de maturação foram avaliadas por PAGE e HPLC-ICP-MS. Aproximadamente 17 bandas protéicas puderam ser observadas por PAGE, sendo a banda de 43 kDa a mais intensa. Alguns picos foram detectados para cada elemento por cromatografia líquida por exclusão de tamanho. Todos os elementos apresentaram pelo menos uma fração acima do volume morto da coluna. O Fe e o Zn, além dessa fração, apresentaram também uma fração de 17 e 27 kDa, respectivamente.
|
846 |
Avaliação e correção de interferências na determinação de As e Se por técnicas com plasma acoplado indutivamente / Evaluation and correction of interferences on the determination of As and Se by inductively coupled plasma techniquesPereira, Catarinie Diniz 28 February 2012 (has links)
Made available in DSpace on 2016-06-02T20:34:34Z (GMT). No. of bitstreams: 1
4229.pdf: 1387001 bytes, checksum: d14ba2ac61a7f1640dca6c559b7a164a (MD5)
Previous issue date: 2012-02-28 / Universidade Federal de Sao Carlos / The aim of the thesis was to evaluate different strategies for correcting spectral and non-spectral interferences on As and Se determination by inductively coupled plasma optical emission spectrometry (ICP OES) and mass spectrometry (ICP-MS) techniques. The determination of 75As+ and 80Se+ isotopes by ICP-MS is strongly affected by the presence of 40Ar35Cl+ and 40Ar2 +, respectively. These interferences can be solved using strategies of sample preparation, cool plasma and more recently collisions and reactions cells. It was studied here a new device for correcting those spectral interferences by the introduction of H2 and He gases through the sampler and skimmer cones present in the collision reaction interface (CRI). The introduction of H2 gas through the skimmer cone was more efficient for destroying polyatomic ions. Lower limits of detection (LOD), 0.019 and 0.097 ng mL-1 for 75As+ and 80 Se+ isotopes, respectively, were obtained by adding 80 mL min-1 H2 through the skimmer cone. The accuracy was demonstrated using two certified reference materials oyster tissue and mussel tissue. Matrix effects may also be corrected using suitable calibration strategies, such as internal standard or the standard additions method. For determination of As and Se by ICP OES it was evaluated a new nebulizer named FB®MN to correct matrix effects and to reduce interferences applying on-line calibration strategies. The aerosol generated by FB®MN was characterized and compared with the aerosol generated by a conventional pneumatic nebulizer (Micromist®). Solutions containing 0.05 and 0.10 mol L-1 Na, K, Ca, Mg, or a mixture of them were used as synthetic matrices. Germanium, In and Y were tested as internal standards. Best recoveries were achieved when 1 mg L-1 of In was used as internal standard. The values of D3,2 and D50 parameters demonstrated that the aerosol produced by using FB®MN has smaller drops than the aerosol produced by using Micromist®. In this study the FB®MN was also used for generation of As and Se XV hydrides directly into the aerosol formed inside the nebulization chamber before detection by ICP OES. The FB®MN allowed the hydrides generation directly into the spray chamber without using any additional device either for solution and gases control or for gas phase separation. Synthetic solutions containing As and Se plus Ca, Mg and K were used for evaluating hydride generation. Germanium, In and Y were tested as internal standards. Accuracy was assessed using addition-recovery experiments in synthetic solutions. Best recoveries for all media were achieved when Ge was used as internal standard. Limits of detection (LOD, 3σ blank) of 2.7 and 5.8 μg L-1 were obtained for As (228.812 nm) and Se (196.016 nm), respectively, when keeping the nebulization gas flow rate at 0.6 L min-1 and the liquid flow rate at 0.67 mL min-1. / Este projeto de pesquisa visou avaliar diferentes estratégias para correção de interferências espectrais e não espectrais na determinação de As e Se por espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES) e espectrometria de massa com plasma acoplado indutivamente (ICP-MS). As medidas dos isótopos 75As+ e 80Se+ em ICP -MS são fortemente afetadas pela presença dos interferentes poliatômicos 40Ar35Cl+ e 40Ar2 +, respectivamente. Esses processos podem ser resolvidos usando estratégias de preparo de amostra, plasma frio e, mais modernamente, interfaces com sistemas de colisões e reações. Foi estudada como ferramenta para remoção de interferências espectrais a introdução de diferentes gases (H2 e He) nos cones de amostragem e skimmer presentes na interface de colisão e reação (CRI). A introdução do gás H2 através do cone skimmer foi mais eficiente na remoção dos interferentes poliatômicos. Os melhores limites de detecção (LOD) 0,019 e 0,097 ng mL-1 para os isótopos 75As+ e 80Se+, respectivamente, foram obtidos introduzindo 80 mL min-1 de H2 no cone skimmer. A exatidão foi comprovada empregando dois materiais de referência certificado, Tecido de ostra e Tecido de molusco. Os efeitos de matriz podem ser atenuados usando estratégias de calibração adequadas, tais como a utilização de um padrão interno ou calibração com adições de padrão. Para determinação de As e Se por ICP OES foi avaliado o multinebulizador Flow Blurring (FB®MN) para corrigir efeitos de matriz e reduzir interferências empregando a estratégia de calibração em linha. O aerossol gerado pelo FB®MN foi caracterizado e comparado com o aerossol gerado por um nebulizador pneumático convencional (Micromist®). Soluções contendo 0,050 e 0,10 mol L-1 de Na, K, Ca, Mg e uma mistura de todos esses elementos foram usadas neste estudo. Na calibração externa e on-line foram testados os elementos Ge, In e Y como padrão interno. Melhores valores de recuperação para As e Se foram obtidos utilizando-se solução 1 mg L-1 de In como padrão interno. Os valores dos parâmetros D3,2 e D50 demonstraram que o aerossol produzido pelo FB®MN se caracteriza por gotas com menores diâmetros comparativamente ao aerossol gerado pelo MicroMist®. Neste estudo também foi avaliado a formação de espécies voláteis na câmara de nebulização para determinação de As e Se por ICP OES utilizando o FB®MN ao invés de qualquer dispositivo para controle de soluções e gases ou separação da fase gasosa. Soluções contendo As e Se em meio de Ca, Mg e K foram usadas para avaliar a geração de hidretos. Germânio, índio e ítrio foram testados como padrão interno. A exatidão foi avaliada usando testes de adição e recuperação em soluções sintéticas. Melhores recuperações para todos os meios foram alcançadas quando o Ge foi utilizado como padrão interno. Os limites de detecção (LOD s 3σ branco) alcançados utilizando o sistema FB®MN e geração de hidretos foram de 2,7 e 5,8 g L-1 para As (228,812 nm) e Se (196,016 nm), respectivamente, quando a vazão de nebulização foi de 0,6 L min-1 e vazão de líquido de 0,67 mL min-1.
|
847 |
Tratamento metrológico e quimiométrico de dados de ressonância magnética nuclear para amostras de biodiesel em diesel / Metrological and chemometric treatment of nuclear magnetic resonance data for biodiesel in diesel samplesGambarra Neto, Francisco Fernandes 29 March 2012 (has links)
Made available in DSpace on 2016-06-02T20:34:34Z (GMT). No. of bitstreams: 1
4335.pdf: 3194405 bytes, checksum: de192f05ba3d247cec9fc8393b575019 (MD5)
Previous issue date: 2012-03-29 / Universidade Federal de Sao Carlos / The development of instrumentation in Nuclear Magnetic Resonance (NMR) increased the sensitivity of the technique, allowing samples in micro and nanogram scale can be examined. These new technologies enabled the NMR technique was seen as an analytical tool for the quantification of substances in addition to their use in identifying as traditionally did. Quantitative Nuclear Magnetic Resonance (qNMR) is a very important area that is not widely used in analytical chemistry, with the need for a validation study to verify its ability to quantify by a metrological point of view. The application and validation of methods minimize the potential problems associated with the analytical method and also lends credence to the method studied, providing comprehensive information about many important aspects that reflect the behavior and reliability of the method. The validation studies of methods RMNq were performed in accordance with ISO / IEC 17025 and ISO GUM. The validation of the method is followed by measuring the uncertainty of measurement qNMR and its importance has been widespread in the analytical chemists area and also in the chemical society in general. The rules for establishing chemical activity as a source of patterning the selectivity studies, investigating the effects of interferents likely in the samples, and for the NMR technique, it is superior to many other analytical instruments. Therefore, the objective of this study was to provide quantitative and alternatives tools, taking into account the metrological quantification of substances by 1H NMR, which is something absolutely new for the Brazilian market. The measure of the selectivity was performed using quantification chemometrics in the spectra of 1H and 13C NMR. Metrology of the main interfering in the 1H NMR technique was studied to quantify the levels of biodiesel in commercial samples and standards of diesel in different proportions in the mixture of biodiesel BX. This study led to the separation of two sets of samples which, by classification using the chemometrics algorithm Successive projection algorithm - Linear Discriminant Analysis (SPA-LDA), are widely separated in diesel fuel containing sulfur in 1800 and 500 ppm . The selectivity was calculated by the quantification chemometric by the algorithm SPA - Multiple linear regression (SPA-MLR) of sulfur content, the density at 20°C, the distillation temperature to 50% and 80% of diesel oil, the cetane number and flash point compared to the results obtained by laboratory (Laboratório de Combustíveis do CCDM/DEMa Universidade Federal de São Carlos) accredited by the ANP (Agência Nacional de Petróleo e Biocobumstíveis). / O desenvolvimento da instrumentação na Ressonância Magnética Nuclear (RMN) aumentou a sensibilidade da técnica, permitindo que amostras em escalas de micro e nanogramas possam ser analisadas. Essas novas tecnologias possibilitaram que a técnica de RMN fosse vista como uma ferramenta analítica para a quantificação de substâncias além do seu uso na identificação como tradicionalmente se fazia. A Ressonância Magnética Nuclear quantitativa (RMNq) é uma área muito importante que ainda é pouco utilizada na química analítica, havendo a necessidade de um estudo de validação para verificar sua capacidade de quantificação por um ponto de vista metrológico. As aplicações de validação de métodos minimizam os problemas potenciais associados com o método analítico e também dão credibilidade ao método estudado, fornecendo informações abrangentes sobre muitos aspectos importantes que refletem o comportamento e a confiabilidade do método. Os estudos de validação de métodos de RMNq foram realizados em conformidade com a norma ISO/IEC 17025 e ISO GUM. A validação do método é seguida pela medida da incerteza de medição em RMNq e a sua importância vem sendo difundida no meio dos químicos analíticos e em meio à sociedade química em geral. As normas de atividade química instituem como fonte de padronização os estudos de seletividade, que investigam os efeitos dos prováveis interferentes nas amostras e, para a técnica RMN, ela é superior a muitos outros instrumentos analíticos. Portanto, o objetivo desse trabalho foi o de apresentar ferramentas quantitativas alternativas, levando em consideração a metrologia na quantificação de substâncias por RMN de 1H, o que é algo absolutamente novo para o comércio brasileiro. A medida da seletividade foi realizada utilizando-se a quimiometria de quantificação nos espectros de RMN de 1H e 13C. A metrologia dos principais interferentes da técnica RMN de 1H foi estudada para a quantificação dos teores de biodiesel, em amostras padrões e comerciais de óleo diesel em diferentes proporções de biodiesel na mistura BX. Este estudo levou à separação de dois conjuntos de amostras os quais, por quimiometria de classificação utilizando-se o algoritmo Successive projection algorithm Linear discriminant analysis (SPA-LDA), foram amplamente separados em óleo diesel contendo teores de enxofre em 1800 e 500 ppm. A seletividade foi calculada pela quimiometria de quantificação, através do algoritmo SPA - Multiple linear regression (SPA-MLR), do teor de enxofre, da massa específica à 20 ºC, da temperatura de destilação a 50% e a 80% do óleo diesel, do índice de cetano e do ponto de fulgor comparados aos resultados obtidos por laboratório (Laboratório de Combustíveis do CCDM/DEMa da Universidade Federal de São Carlos) credenciado pela ANP (Agência Nacional do Petróleo).
|
848 |
Desenvolvimento de biossensores utilizando nanotubos de carbono e nanopartículas de ouro / Development of biosensors using carbon nanotubes and gold nanoparticlesJanegitz, Bruno Campos 22 June 2012 (has links)
Made available in DSpace on 2016-06-02T20:34:35Z (GMT). No. of bitstreams: 1
4417.pdf: 4764292 bytes, checksum: f843bb063e4e62585bcaf3a316f53db2 (MD5)
Previous issue date: 2012-06-22 / Universidade Federal de Minas Gerais / First, a glassy carbon electrode modified with functionalized carbon nanotubes (CNTs) and glucose oxidase was proposed. Cyclic voltammetry of GOx immobilized onto the surface of CNTs showed a pair of well-defined redox peaks, which corresponds to the direct electron transfer of GOx, with a formal potential of -0.418 V in 0.1 mol L-1 phosphate buffer solution (pH 7.0). An apparent heterogeneous electron transfer rate constant of 1.69 s-1 was obtained. The determination of glucose was carried out by square wave voltammetry and the developed biosensor showed good reproducibility and stability. The second biosensor was a boron-doped diamond electrode modified with AuNPs electrodeposited and Tyrosinase (Tyr). The occurrence of direct electron transfer between the electrode surface and the Tyr active site was verified by cyclic voltammetry, yielding the following parameter values: formal redox potential of 0.115 V. The developed Tyr-AuNPs/BDD biosensor exhibits good sensitivity, stability, and reproducibility for the determination of phenol by SWV. The third proposed biosensor was developed based on acetylcholinesterase, gold nanoparticles and poly (allylamine hydrochloride) film on the surface of screen printed carbon electrodes (SPCE) for the determination of pesticides using a portable micromachined flow injection system. The AChE-AuNPs/SPCE biosensor presented a limit of detection of 5.0 x 10-8 mol L-1 for Diuron. In addition, the biosensor showed good sensitivity, stability and reproducibility for Diuron determination in water samples. Finally, a novel electrochemical immunosensor using electrodeposited gold nanoparticles modified-screen-printed carbon electrodes (AuNPs/SPCEs) was developed for the determination of prolactin.The variables involved in the preparation of the immunosensor and the electrochemical detection step were optimized, which presented a limit of detection of 10 ng mL-1. The analytical usefulness of the immnunosensor for the analysis of real samples was demonstrated by analyzing human serum spiked with PRL at two different concentration levels. / Primeiramente desenvolveu-se uma nova arquitetura de um biossensor para glicose utilizando-se a enzima glicose oxidase (GOx) imobilizada em nanotubos de carbono funcionalizados (CNTs) e dihexadecil hidrogenio fosfato (DHP) sobre a superficie de carbono vitreo (GCE). Resultados de voltametria ciclica apresentaram um par de picos redox bem definidos, correspondente a transferencia eletronica direta da GOx para o eletrodo, com o potencial formal de -0,418 V (vs. Ag/AgCl (KCl 3,0 mol L-1)). O biossensor foi aplicado na determinacao de glicose, o qual mostrou boas reprodutibilidade, estabilidade e seletividade. O segundo biossensor desenvolvido foi aquele utilizando-se a enzima tirosinase (Tyr) imobilizada em nanoparticulas de ouro sobre a superficie de um eletrodo de diamante dopado com boro. Resultados de voltametria ciclica apresentaram um par de picos redox bem definidos, correspondente a transferencia eletronica direta da Tyr. As determinacoes de fenol foram realizadas por SWV e o biossensor proposto apresentou um limite de deteccao de 0,07 μmol L-1. Em sequencia foi proposto um biossensor para a determinacao de pesticidas utilizando-se a enzima acetilcolinesterase imobilizada sobre filme de nanoparticulas de ouro e hidrocloreto de polialilamina sobre a superficie de eletrodos de carbono impresso (SPCE). O eletrodo AChE-AuNPs/SPCE apresentou um limite de deteccao de 5,0 x 10-8 mol L-1 para Diuron, alem de boa estabilidade e reprodutibilidade para a determinacao do pesticida por amperometria. Por fim foi proposto tambem um imunossensor usando nanoparticulas de ouro eletrodepositadas sobre eletrodos de carbono impresso (AuNPs/SPCEs) para a determinacao de prolactina. Os anticorpos antiprolactina biotinilada foram imobilizados em AuNPs/SPCEs modificados com estreptavidina em um imunoensaio do tipo sanduiche envolvendo o analito e um anticorpo antiprolactina marcado com fosfatase alcalina (AP). O imunossensor proposto apresentou um limite de deteccao de 10 ng mL-1 e foi aplicado com sucesso em amostras de soro humano enriquecido com prolactina comprovando a eficacia do procedimento proposto.
|
849 |
Desenvolvimento de imunossensores piezelétrico e eletroquímico para detecção de amostras de interesse agronômico e de saúde / Desenvolvimento de imunossensores piezelétrico e eletroquímico para detecção de amostras de interesse agronômico e de saúde / Development of piezoelectric and electrochemical immunosensors to detect samples of agronomic interest and public health / Development of piezoelectric and electrochemical immunosensors to detect samples of agronomic interest and public healthAfonso, André Santiago 23 July 2012 (has links)
Made available in DSpace on 2016-06-02T20:34:36Z (GMT). No. of bitstreams: 1
4462.pdf: 4273464 bytes, checksum: 0edd147ff165382e58073330d180f98d (MD5)
Previous issue date: 2012-07-23 / Universidade Federal de Sao Carlos / This work shows development of immunosensors for agronomic interest and public heath. The first was a piezoeletric immunosensor to detect a cysteine peptidase, a potencial biomarker for Xanthomonas citri subsp. citri that cause a citrus Canker. Another was electrochemical immunosensor based on gold nanoparticles as a label and magnetic beads as capture phase of Salmonella enterica subsp. enterica sorovar Typhimurium LT2 (S). The piezoelectric immunoassay was based on immobilization of polyclonal antibody against CPXaC (anti-CPXaC), produced in rabbit, onto three different monolayers that modified gold quartz crystal, which were evaluated by monitoring frequency and energy dissipation in real time when 64.5×10-8 mol L-1 of CPXaC was added. The better relation between analytical response and energy dissipation was obtained with immobilization onto 11- mercaptoundecanoic acid which presented a detection limit of 13.0 nmol L-1 as well as good values for the kinetic and equilibrium binding constant. The immunosensor showed good specificity with no response for different proteins include another cysteine peptidase that is used as a target for detects Xylella fastidiosa bacterium responsible for other important disease in citrus. For detection of Salmonella using a magneto-immunoassay and gold nanoparticles (AuNPs) as label was developed based on the use of a screen-printed carbon electrode (SPCE) that incorporates a permanent magnet underneath. Salmonella spiked in milk samples (i.e. skimmed milk) have been tested by using anti-Salmonella magnetic beads (MBs-SAb) as capture phase and sandwiching afterwards with AuNPs modified antibodies (SAb-AuNPs). AuNPs detection using differential pulse voltammetry (DPV) following a previous established procedure is performed. And a detection limit of 143 CFU mL-1 and a linear range of from 103 to 106 CFU mL-1 of Salmonella, with a coefficient of variation of about 2.4%, was obtained. Recoveries of the sensor by spiking skimmed milk with different quantities of Salmonella of about 83 and 94 % for xviii 1.5 x 103 and 1.5 x 105 CFU mL-1 were obtained, respectively. This work demonstrated the possibility to detect CPXaC with a piezoelectric immunosensor as well as electrochemical immunosensor to detect Salmonella spiked in milk samples. / No presente trabalho estudou-se o desenvolvimento de imunossensores para aplicação em amostras de interesse agronômico e de saúde. Foram desenvolvidos um imunossensor piezelétrico para cisteíno peptidase (CPXaC), um potencial biomarcador para Xanthomonas citri subsp. citri (Xcc) causadora do Cancro cítrico, e um imunossensor eletroquímico baseado em nanopartículas de ouro como marcador e utilizando partículas magnéticas para separação e pré-concentração de Salmonela enterica subsp. enterica sorovar Typhimurium LT2 (S). O imunoensensor piezelétrico foi baseado em três estratégias de imobilização do anticorpo policlonal anti-CPXaC, produzido em coelho, contra CPXaC sobre a superfície de ouro do cristal de quartzo. As superfícies de imobilização foram avaliadas monitorando a variação da frequência ressonante do cristal de quartzo (Δ ) e o valor da dissipação de energia (ΔD) em tempo real adicionando 645×10-9 mol L-1 CPXaC. A melhor relação entre resposta analítica e dissipação de energia do imunossensor foi obtida com a imobilização do anticorpo sobre ácido 11-mercaptoundecanóico (MUA), o qual apresentou um limite de detecção de 13,0 nmol L-1, bem como valores de constante cinética e de equilíbrio para interação antígeno-anticorpo concordantes com os da literatura. Por fim, o imunossensor apresentou boa especificidade não apresentando resposta para diferentes proteínas estudas, incluindo outra cisteíno peptidase que é usada com alvo para detectar Xylella fastidiosa, bactéria responsável por outra importante doença de cítrus. A detecção de Salmonela utilizando um magneto-imunoensaio e nanopartículas de ouro (AuNPs) como marcador foi desenvolvido utilizando um eletrodo de carbono impresso (SPCE) que incorpora um ímã permanente. Amostras de leite desnatado fortificadas com Salmonela foram testadas usando partículas magnéticas modificadas com anti-Salmonela (MBs-SAc), para a fase de separação e pré-concentração, e marcadas posteriomente com nanopartículas de ouro (AuNPs) modificados com anticorpo secundário anti-salmonela (SAcxvi AuNPs), o qual foi detectado usando voltametria de pulso diferencial (DPV). Um limite de detecção de 143 CFU mL-1 e um intervalo linear 103-106 CFU mL-1 de Salmonela, com um coeficiente de variação de cerca de 2,4%, foram obtidos. As recuperações do sensor em leite desnatado foram de 83 e 94% para 1,5 x 103 e 1,5 x 105 CFU mL-1, respectivamente. Este trabalho demonstrou com sucesso a possibilidade do uso de imunossensores piezelétricos para detectar CPXaC, bem como um imunossensor eletroquímico para detectar Salmonela em amostras de leite fortificadas.
|
850 |
Avaliação de procedimentos para preparo de amostras agronômicas visando determinação multielementar por espectrometria de emissão ótica com plasma induzido. / Evaluation of procedures for agricultural samples preparation for multielemental determination by inductively coupled plasma optical emission spectrometry.Silva, Fernando Vitorino da 21 May 2004 (has links)
Made available in DSpace on 2016-06-02T20:34:37Z (GMT). No. of bitstreams: 1
TeseFVS.pdf: 1918366 bytes, checksum: 50022552c1da9e36f2b0f548d6bafb0d (MD5)
Previous issue date: 2004-05-21 / Universidade Federal de Minas Gerais / Sample preparation was always considered a limiting factor for sample
throughput in the analytical sequence due to its high time consumption and great
probability for error insertion in the results. Therefore, purposes to generate
lower analysis time and, mainly, to make sample handling a feasible process are
readily wished. Two procedures for preparation of agricultural samples (bovine
milk and fruit juices) for multielemental determination by inductively coupled
plasma optical emission spectrometry have been investigated. A procedure for
bovine milk treatment based on use of proteolytic enzymes (pepsin) and protein
precipitator agent (trichloroacetic acid) for extraction of Ca, Fe, Mg, and Zn was
investigated. Application of these reagents allowed to check the complex
interaction between Fe and milk proteins. Quantitative determinations from
simple protein precipitation in solution showed good results for Ca, Mg, and Zn.
Results obtained for Fe, using protein precipitation, confirmed the strong bound
of this element with the casein micelle. In general, the recovery of Fe on protein
precipitate was around 100 %. Taking into account the procedure for fruit juices
treatment, a flow system operating at high temperature and high pressure was
developed. This system presented decomposition efficiency around 99 % for
different carbon sources when 300 oC and 60 bar was applied. As result, it can
be suggested that the use of diluted nitric acid (HNO3 1.4 mol L-1) associated to
hydrogen peroxide as auxiliary oxidant agent (H2O2 3.0 % v v-1), does not
compromise the decomposition efficiency if high temperature is applied.
Recoveries of Ca, K, Mg, and Na in the digestates obtained by the flow system
were in agreement with those found in the closed vessel-MW assisted acid
decomposition. The flow system behavior for vegetal tissues slurries
decomposition was also evaluated. At the same time the spectrometers
performance was evaluated. Figures of merit, warm up time, long and short term
stability, spectral resolution, and limit of detection were compared for axially-
and radially-viewed configurations. The performed experiments showed similar
performance for both configurations, differing only on the warm up time and
limit of detection. Taking into account the obtained results it is possible to infer
that most of the applications performed with the radially-viewed configuration
could be carried out in axially-viewed ICP OES s with no analytical
performance degradation. / A etapa de preparo da amostra sempre foi considerada um fator limitante a
produtividade dentro da seqüência analítica devido ao elevado tempo
demandado e a grande probabilidade da introdução de erros no resultado
analítico. Propostas que venham representar economia em tempo e simplificação
da manipulação da amostra são desejáveis. Foram investigados dois
procedimentos para preparo de amostras agronômicas (leite bovino e sucos de
fruta) visando determinação multielementar por espectrometria de emissão ótica
com plasma induzido. O procedimento para preparo do leite bovino baseou-se
no emprego de enzima proteolítica (pepsina) e de agente precipitador de
proteínas (ácido tricloroacético), para extração dos elementos Ca, Fe, Mg e Zn.
A aplicação dos reagentes avaliados proporcionou verificar a complexa
interação do elemento Fe com as proteínas do leite. Determinação quantitativa a
partir da simples precipitação das proteínas mostrou-se viável para Ca, Mg e Zn.
Resultados obtidos para Fe, utilizando a precipitação das proteínas, confirmaram
a forte ligação desse elemento com a micela de caseína. Em geral, a recuperação
de Fe no precipitado de proteínas desnaturadas apresentou-se ao redor de 100 %.
Para tratamento das amostras de sucos de frutas foi desenvolvido um sistema em
fluxo que opera sob altas temperatura e pressão. Esse sistema mostrou eficiência
de decomposição de aproximadamente 99 %, para diferentes fontes de carbono,
quando as condições de 300 oC e 60 atm foram utilizadas. A utilização de ácido
nítrico diluído (HNO3 1,4 mol L-1), associada ao uso de peróxido de hidrogênio
como agente oxidante auxiliar (H2O2 3,0 % v v-1), não comprometeu a eficiência
de decomposição quando temperatura de 300oC foi empregada. Os teores de Ca,
K, Mg e Na encontrados nos digeridos das amostras de sucos foram
concordantes às concentrações observadas para digestão em forno de MW com
frascos pressurizados. O comportamento do sistema em fluxo frente a
suspensões de tecido vegetal também foi investigado. Ao mesmo tempo foi
avaliada a performance dos espectrômetros utilizados nas determinações. Foram
comparadas as figuras de mérito, warm-up time , estabilidades em curto e
longo períodos, resolução espectral, robustez e limite de detecção para as
configurações axial e radial. Os experimentos realizados mostraram desempenho
similar para ambas as configurações, sendo observadas diferenças apenas no
warm up time e limite de detecção. Os resultados obtidos possibilitam
concluir que a maioria das aplicações realizadas com a configuração radial pode
ser implementada em um ICP OES com visão axial sem degradação do
desempenho analítico.
|