• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 91
  • 62
  • 13
  • 7
  • 5
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 284
  • 99
  • 45
  • 42
  • 40
  • 40
  • 38
  • 34
  • 27
  • 18
  • 18
  • 18
  • 18
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Dosimetry Studies of Different Radiotherapy Applications using Monte Carlo Radiation Transport Calculations

Abbasinejad Enger, Shirin January 2008 (has links)
<p>Developing radiation delivery systems for optimisation of absorbed dose to the target without normal tissue toxicity requires advanced calculations for transport of radiation. In this thesis absorbed dose and fluence in different radiotherapy applications were calculated by using Monte Carlo (MC) simulations.</p><p>In paper I-III external neutron activation of gadolinium (Gd) for intravascular brachytherapy (GdNCB) and tumour therapy (GdNCT) was investigated. MC codes MCNP and GEANT4 were compared. MCNP was chosen for neutron capture reaction calculations. Gd neutron capture reaction includes both very short range (Auger electrons) and long range (IC electrons and gamma) products. In GdNCB the high-energetic gamma gives an almost flat absorbed dose delivery pattern, up to 4 mm around the stent. Dose distribution at the edges and inside the stent may prevent stent edge and in-stent restenosis. For GdNCT the absorbed dose from prompt gamma will dominate over the dose from IC and Auger electrons in an in vivo situation. The absorbed dose from IC electrons will enhance the total absorbed dose in the tumours and contribute to the cell killing.</p><p>In paper IV a model for calculation of inter-cluster cross-fire radiation dose from β-emitting radionuclides in a breast cancer model was developed. GEANT4 was used for obtaining absorbed dose. The dose internally in cells binding the isotope (self-dose) increased with decreasing β-energy except for the radionuclides with substantial amounts of conversion electrons and Auger electrons. An effective therapy approach may be a combination of radionuclides where the high self-dose from nuclides with low β-energy should be combined with the inter-cell cluster cross-fire dose from high energy β-particles.</p><p>In paper V MC simulations using correlated sampling together with importance sampling were used to calculate spectra perturbations in detector volumes caused by the detector silicon chip and its encapsulation. Penelope and EGSnrc were used and yielded similar results. The low energy part of the electron spectrum increased but to a less extent if the silicon detector was encapsulated in low z-materials.</p>
202

A study of the binding of trace metals and radionuclides by humic substances

Peters, Adam J. January 1999 (has links)
No description available.
203

Aqueous and solid phase interactions of radionuclides with organic complexing agents

Reinoso-Maset, Estela January 2010 (has links)
Characterising the geochemistry and speciation of major contaminant radionuclides is crucial in order to understand their behaviour and migration in complex environmental systems. Organic complexing agents used in nuclear decontamination have been found to enhance migration of radionuclides at contaminated sites; however, the mechanisms of the interactions in complex environments are poorly understood. In this work, radionuclide speciation and sorption behaviour were investigated in order to identify interactions between four key radionuclides with different oxidation states (Cs(I) and Sr(II) as important fission products; Th(IV) and U(VI) as representative actinides), three anthropogenic organic complexing agents with different denticities (EDTA, NTA and picolinic acid as common co-contaminants), and natural sand (as simple environmental solid phase). A UV spectrophotometric and an IC method were developed to monitor the behaviour of EDTA, NTA and picolinic acid in the later experiments. The optimised methods were simple, applied widely-available instrumentation and achieved the necessary analytical figures of merit to allow a compound specific determination over variable background levels of DOC and in the presence of natural cations, anions and radionuclides. The effect of the ligands on the solubility of the radionuclides was studied using a natural sand matrix and pure silica for comparison of anions, cations and organic carbon. In the silica system, the presence of EDTA, NTA and, to a lesser extent, picolinic acid, showed a clear net effect of increasing Th and U solubility. Conversely, in the sand system, the sorption of Th and U was kinetically controlled and radionuclide complexation by the ligands enhanced the rate of sorption, by a mechanism identified as metal exchange with matrix metals. Experiments in which excess EDTA, NTA and picolinic acid (40 – 100 fold excess) were pre-equilibrated with Th and U prior to contact with the sand, to allow a greater degree of radionuclide complex formation, resulted in enhanced rates of sorption. This confirmed that the radionuclide complexes interacted with the sand surface more readily than uncomplexed Th or U. Overall this shows that Th and U mobility would be lowered in this natural sand by the presence of organic co-contaminants. In contrast, the complexation of Sr with the complexing agents was rapid and the effect of the ligands was observed as a net increase on Sr solubility (EDTA, picolinic acid) or sorption (NTA). As expected, Cs did not interact with the ligands, and showed rapid sorption kinetics. Finally, ESI-MS was used to study competitive interactions in the aqueous Th-Mn-ligand ternary system. Quantification presented a challenge, however, the careful approach taken to determine the signal correction allowed the competitive interactions between Mn and Th for EDTA to be studied semi-quantitatively. In an EDTA limited system, Th displaced Mn from the EDTA complex, even in the presence of a higher Mn concentration, which was consistent with the higher stability constant of the Th-EDTA complex.
204

Valor prognóstico de provas funcionais na evolução tardia de pacientes com infarto agudo do miocárdio tratados com angioplastia coronária transluminal percutânea primária com implante de stent / Prognostic value of non-invasive functional tests during the follow-up of acute myocardial infarction treated with primary coronary stenting

Büchler, Rica Dodo Delmar 25 June 2007 (has links)
Introdução: A angioplastia primária associada ao implante de stent é o tratamento de escolha no infarto agudo do miocárdio. Discute-se o valor de provas funcionais na abordagem de reestenose coronária, bem como o tempo ideal para sua realização. O objetivo deste estudo foi avaliar a importância do teste ergométrico, da cintilografia de perfusão miocárdica e do ecocardiograma bidimensional em repouso, no diagnóstico de reestenose em pacientes tratados durante as primeiras 12 horas de evolução do infarto com supra desnivelamento do segmento ST. Métodos: No período de agosto de 2003 a janeiro de 2006 foram selecionados 64 pacientes tratados com angioplastia primária e implante de stent nas primeiras 12 horas de evolução do primeiro infarto. Os pacientes realizaram ecocardiograma bidimensional em repouso, teste ergométrico com adição de derivações precordiais direitas e cintilografia de perfusão miocárdica com captação tomográfica (SPECT) sincronizada ao ECG (GATED SPECT), seis semanas (etapa1), seis meses (etapa 2) e um ano (etapa3) após a angioplastia primária. Foi realizado reestudo angiográfico no sexto mês de evolução. Resultados: A idade média foi 56,2 ±10,2 anos; 53 pacientes eram do sexo masculino. Doença uniarterial > = 50% foi observada em 46,9% dos casos. A artéria descendente anterior foi tratada em 48,4% dos pacientes, artéria coronária direita em 34,4%, artéria circunflexa em 10,9%, tronco de coronária esquerda em 3,1%,grande ramo diagonal em 1,6% e ponte safena em 1,6%. Reestenose angiográfica ocorreu em 28.8% dos 59 casos submetidos a reestudo. A fração de ejeção do ventrículo esquerdo ao ecocardiograma foi em média: 0,55 (etapa 1), 0,55 (etapa 2) e 0,56 (etapa 3). Observou-se diferença entre a fração de ejeção dos pacientes com e sem reestenose um ano após o procedimento (p=0,003). Sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia do teste ergométrico foram respectivamente: 53,3%, 69% , 38,1%, 80,6% e 64,9% na etapa 1 (p=0,123); 54,5%, 70,7%, 33,3%, 85,3% e 67,3% na etapa 2(p=0,159) e 38,5%, 66,7%, 27,8% ,76,5% e 59,6% na etapa 3 (p=0,747). A adição de derivações precordiais direitas não elevou os índices de sensibilidade em nenhuma das etapas. Os valores de sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácía obtidos após a cintilografia de perfusão miocárdica com MIBI, quando considerada a diferença de escores entre esforço e repouso >2, foram respectivamente 40%,78,6%, 40%, 78,6% e 68,4% na etapa1(p=0,185); 54,5%,87,8%,54,5%,87,8% e 80,8% na etapa 2 (p=0,006) e 25%,91,7%,50%,78,6% e 75% na etapa 3(p=0,156). Quando considerada a diferença de escores >4 os valores foram respectivamente: 13,3%,88,1%,28,6% ,74% e 68,4% na etapa 1(p>0,999); 36,4%,95,1%,66,7%,84,8% e 82,7% na etapa 2 (p=0,014) e 8,3%,94,4 %,33,3%,75,6% e 72,9 % na etapa 3 (p >0,999). Conclusões: O teste ergométrico não permitiu discriminar reestenose na população estudada, em nenhuma das etapas durante a evolução. A cintilografia miocárdica realizada seis meses após o infarto apresentou associação com reestenose. Os pacientes com reestenose apresentaram menores valores de fração de ejeção do ventrículo esquerdo um ano após a angioplastia primária, por avaliação ecocardiográfica. / Primary coronary angioplasty and stenting during acute myocardial infarction is the first treatment choice. Non-invasive testings have been used in the diagnosis of restenosis but its efficacy and time to be performed have to be determined. The purpose of this study was to evaluate exercise treadmill test, myocardial perfusion imaging and rest two-dimensional echocardiogram in the diagnosis of restenosis in patients treated during the first 12 hours of STelevation myocardial infarction.Methods: From August 2003 to January 2006, 64 patients were selected after primary coronary angioplasty and stenting. Rest two- dimensional echocardiogram, exercise treadmill test associated to right precordial leads and myocardial perfusion imaging according to GATED-SPECT were performed 6 weeks (step 1), 6 months (step 2) and one year (step 3) after the procedure.Coronary angiography was performed during the sixth month of follow-up.Results : Mean age was 56.2 ± 10.2 years; 53 patients were male. Single vessel disease > = 50% was observed in 46.9% of patients. The left anterior descending coronary artery was treated in 48.4%, the right coronary artery in 34.4%, the left circumflex in 10.9%, the left main coronary artery in 3.1%, a large diagonal branch in 1.6% and saphenous vein graft in 1.6% of the cases. Angiographic restenosis occurred in 28.8% from 59 patients submitted to coronary angiography. Mean left ventricular ejection fraction observed during rest two-dimensional echocardiogram was: 0.55 (step 1), 0.55 (step 2) and 0.56 (step 3). It was observed in patients with and without restenosis a significant difference in the left ventricular ejection fraction one year after the procedure (p= 0.003). Exercise treadmill test sensitivity, specificity, positive and negative predictive values and accuracy were respectively: 53.3%, 69%, 38.1%, 80.6% and 64.9% in step 1(p=0.123); 54.5%, 70.7%, 33.3%, 85.3% and 67.3% in step 2 (p=0.159) and 38.5%, 66.7%, 27.8%, 76.5% and 59.6% in step 3 (p=0.747). Right precordial leads did not show any additional significance. Sensitivity, specificity, positive and negative predictive values and accuracy during myocardial perfusion imaging when considering summed difference score > 2 were respectively: 40%, 78.6%, 40%, 78.6% and 68.4% in step 1(p=0.185); 54.5%, 87.8%, 54.5%,87.8% and 80.8% in step 2(p=0.006) and 25%, 91.7%, 50%, 78.6% and 75% in step 3(p=0.156). When considering summed difference score > 4 they were respectively: 13.3%, 88.1%, 28.6%, 74% and 68.4% in step 1(p> 0.999); 36.4%, 95.1%,66.7%, 84.8% and 82.7% in step 2 (p=0.014) and 8.3%, 94.4%, 33.3%, 75.6% and 72.9% in step 3(p> 0.999). Conclusions: Exercise treadmill test did not allow to discriminate restenosis in this population in all steps.Myocardial perfusion imaging performed 6 months after acute myocardial infarction was associated to restenosis. Patients with restenosis showed lower left ventricular ejection fraction one year after acute myocardial infarction by rest two-dimensional echocardiogram.
205

Teoria de conjuntos fuzzy e regressão logística na tomada de decisão para realização de cintilografia das paratiróides / Fuzzy sets theory and logistic regression in decision making for parathyroid scintigraphy investigation

Sousa, Clóvis Arlindo de 15 June 2007 (has links)
Introdução - Grande parte das cintilografias das paratiróides realizadas antes da primeira cirurgia (paratiroidectomia) resulta negativa, podendo sugerir uma inadequação na solicitação do exame. Objetivo - Desenvolver e comparar dois modelos matemáticos baseados em teoria de conjuntos fuzzy e regressão logística para tomada de decisão na realização de cintilografia das paratiróides, a partir de valores séricos de Cálcio (Ca) e Paratormônio (PTH). Métodos - Da base de registros de cintilografia de paratiróides realizadas no Centro de Medicina Diagnóstica Fleury, em São Paulo, foram identificados 194 pacientes (grupo desenvolvimento) que no período de janeiro de 2000 a dezembro de 2004 tinham Ca e PTH séricos medidos. Foram desenvolvidos dois modelos matemáticos, um deles baseado em regressão logística e o outro em teoria de conjuntos fuzzy, com a finalidade de definir uma medida de indicação para a realização do exame cintilográfico. O desempenho dos modelos foi comparado utilizando curvas ROC pelo teste de Hanley e McNeil. Utilizou-se o grupo teste de 139 pacientes registrados de 2005 a 2006 para avaliar os modelos e verificar sua acurácia. Resultados - No grupo desenvolvimento, a área sob a curva ROC do modelo de regressão logística foi de 0,86 (IC 95%: 0,81-0,91) e do modelo fuzzy foi 0,89 (IC 95%: 0,84-0,93), avaliadas como estatisticamente distintas (p=0,026). O modelo fuzzy se destacou como particularmente útil porque, ao contrário do modelo logístico, mostrou capacidade de utilizar informações de PTH em intervalo em que os valores de Ca mostraram-se pouco discriminantes. No grupo teste, a área para o modelo logístico foi de 0,89 (IC 95%: 0,83-0,95) e para o modelo fuzzy foi de 0,91 (IC 95%: 0,85-0,96) (p=0,128). Conclusões - O modelo fuzzy apresentou desempenho igual ou superior ao modelo de regressão logística. O modelo matemático baseado em teoria de conjuntos fuzzy, no contexto deste estudo, obteve desempenho mais adequado do que o modelo baseado em regressão logística como método para decisão da realização de cintilografia das paratiróides. Por pertinente, destaque-se que, resultado de um exercício metodológico, inferências sobre o comportamento do objeto podem ser impróprias, dada a não representatividade populacional dos dados. / Introduction - A great number of parathyroid scintigraphies performed before the first surgery (parathyroidectomy) results negative suggesting an inadequate use of this test. Objective - The aim of this study was to develop and compare two mathematical models based on logistic regression analysis and fuzzy sets theory to select patients to be submitted to parathyroid scintigraphy based on serum calcium and parathormone values. Methods - From the data registrered on parathyroid scintigrafy database from Fleury - Medical Diagnostic Center, São Paulo, within the period between January 2000 to December 2004, 194 patients with available serum calcium and parathormone were identified. Two mathematical models based on logistic regression analysis and fuzzy sets theory were developed to recognize patients for parathyroid scintigraphy on the basis of laboratorial exams. The logistic regression model was developed using SPSS and the fuzzy model using MatLab. The performances of the models were compared using ROC curves with the test of Hanley e McNeil. The accuracies of both models were also analyzed and compared using a new database (test database) of 139 parathyroid scintigraphies performed between 2005 and 2006. Results - The performances of the models were statistically different (p=0.026). The area under the ROC curves were 0.86 (CI 95%: 0.81-0.91) for the logistic regression model and 0.89 (CI 95%: 0.84-0.93) for the fuzzy model. As an advantage over the logistic model, the latter has shown the ability to draw decision from parathormone information within a not discriminating interval of calcium values. In the test database the ROC area for the logistic regression model the ROC curve area was 0.89 (CI 95%: 0.83-0.95) and for the fuzzy model was 0.91 (CI 95%: 0.85-0.96) (p=0.128). Conclusions - The mathematical model based on fuzzy sets theory fared better than the logistic model in decision making for scintigraphy indication. Nevertheless, one should take heed that inferences should be kept to what concerns model comparison and not the parathyroid scintigraphy itself, once the data analysed was not representative of any population.
206

Contribuições da cintilografia de perfusão e função miocárdica com duplo isótopo na vigência de baixa dose de dobutamina: avaliação da integridade celular e reserva contrátil na identificação do miocárdio viável / Contributions of perfusion and myocardic cintilography function with double isotope and low dobutamina dose validity: evaluation of cellular integrity and contractile reserve in viable myocardium identification

Moraes, Renata Freire de 24 September 2007 (has links)
Em pacientes portadores de insuficiência coronariana com prognóstico desfavorável pela presença de disfunção ventricular significativa, a pesquisa de viabilidade miocárdica traz contribuições ao predizer a possibilidade de recuperação contrátil após revascularização. Os segmentos miocárdicos com disfunção contrátil por hipoperfusão podem melhorar o desempenho contrátil restabelecido o aporte sanguíneo local, indicando que a revascularização miocárdica, quando bem indicada, é capaz de melhorar a sobrevida deste grupo de pacientes. Realizou-se pesquisa de tese de doutoramento do Departamento de Radiologia da Universidade de São Paulo na unidade de medicina nuclear da Nuclear Medcenter/Hospital SOCOR em Belo Horizonte, Minas Gerais. O objetivo do estudo foi verificar se a cintilografia de perfusão miocárdica com duplo-isótopo (99mTcsestamibi/ cloreto de tálio-201) como método radioisotópico para identificação do músculo viável, tem sua especificidade aumentada com a inclusão de informações sobre reserva contrátil miocárdica obtidas simultaneamente através do gatedSPECT (imagens tomográficas do coração sincronizadas ao eletrocardiograma) na vigência de baixas doses de dobutamina de forma semelhante ao ecocardiograma. Estudou-se 54 pacientes com infarto do miocárdio prévio, encaminhados ao serviço de medicina nuclear para realização de pesquisa de viabilidade miocárdica. Foram excluídos do estudo os pacientes que no seguimento não foram revascularizados ou que não realizaram controle cintilográfico pós-cirúrgico, uma vez que considerouse como critério de viabilidade a melhora da contratilidade miocárdica após a revascularização. Avaliou-se os parâmetros de viabilidade (integridade celular e reserva contrátil) e o desempenho contrátil pós-cirúrgico de 260 segmentos miocárdicos de treze pacientes revascularizados. Os pacientes estudados foram submetidos a cintilografia de perfusão miocárdica duoisotópica em protocolo de dois dias com imagens tomográficas do coração obtidas em gamma-camera de duas cabeças, modelo Varicam (Elscint) e processadas em estação de trabalho eNTEGRA(GE). As imagens de estresse foram adquiridas em sincronia com o ECG (gated SPECT) em condições basais e na vigência de baixa dose de dobutamina (10 a 15g/Kg/min) 45 minutos após a administração endovenosa do 99mTcsestamibi no pico do exercício isotônico (esforço) ou da ação de agentes farmacológicos (estresse farmacológico) e nas etapas de repouso e redistribuição do cloreto de tálio-201, 20 minutos e quatro a seis horas após a administração endovenosa do radioisótopo em condições basais. Os pacientes operados foram submetidos a um segundo estudo cintilográfico de perfusão miocárdica com gated SPECT, no período mínimo de três meses após o procedimento, para avaliação da performance contrátil pós-cirúrgica. Para análise dos achados cintilográficos, dividiu-se o coração em 20 segmentos que receberam diferentes escores, permitindo a quantificação da perfusão e função miocárdica pelo Cedars Sinai Quantitative Pefusion SPECT QPS/QGS(GE),. Analisou-se o padrão perfusional nas etapas de estresse, repouso e redistribuição e de função (análise do espessamento sistólico, motilidade parietal, valores de fração de ejeção e volumes cardíacos do ventrículo esquerdo) em condições basais e sob estímulo inotrópico. No tratamento estatístico a análise do espessamento sistólico foi o parâmetro considerado significativo para avaliação da reserva contrátil miocárdica pelo método. Houve incremento na especificidade da pesquisa de viabilidade miocárdica pelo método radioisotópico realizado, demonstrando valores de especificidade superiores aos encontrados na literatura. As contribuições do método se mostraram efetivas / In patients with coronariopathy in the setting of ventricular dysfunction having an unpromising prognostic, the myocardial viability must be assessed thus, bringing contribution as it can predict the myocardial dysfunction recovery after revascularization. The myocardial segments with contractile dysfunction as a consequence of hypoperfusion can improve wall motion after perfusion recovery, demonstrating that myocardial revascularization, whenever suggested, can improve survival to this group of patients. This research is a PHD thesis from Radiology Department of São Paulo University and was performed at a nuclear medicine unit - Nuclear Medcenter/SOCOR hospital - in Belo Horizonte, Minas Gerais. The aim of the study was to check if dual isotope perfusion myocardial gated SPECT (99mTc-sestamibi/thallium-201) as a nuclear medicine procedure to the identification of viable myocardium, can improve the method specificity with addition of contractile reserve information obtained simultaneously by gated SPECT with low dose of dobutamine, similar to the echocardiogram. 54 patients with myocardial stroke, referred to the nuclear medicine unit to seek myocardial viability have been studied. Patients that do not have been submitted to revascularization or that did not undergo the post surgery control were excluded, as the parameter considered for viability was the wall motion recovery after revascularization. 260 myocardial segments in 13 patients had their viability parameters (cellular integrity and contractile reserve) as the contractile performance after surgery evaluated. The images were acquired by a Varicam (Elscint) double head gamma camera and processed by eNTEGRA (GE) workstation. The gated SPECT stress images were performed in baseline conditions and with low-dose dobutamine (10 a 15g/Kg/min) 45 minutes after intravenous injection of 99mTc-sestamibi.on the peak of isotonic exercise or pharmacologic stress. The rest and redistribution images were acquired , 20 minutes and 4 or 6 hours after intravenous injection of thallium-201 at rest. The revascularizated patients were also submitted to a second gated SPECT study at least 3 months after surgery for evaluation of the contractile performance. In order to analyze the scintigraphic findings, the heart was divided into 20 segments that received different scores for quantification of myocardial perfusion and function by Cedars Sinai Quantitative Perfusion SPECT QPS/QGS(GE),. The perfusion pattern of stress, rest and redistribution and the parameters of function (wall thickening and motion, ejection fraction and cardiac volumes analysis) at baseline conditions and by inotropic effect. By the statistics analysis wall thickening was considered significant to evaluate the myocardial contractile reserve by this method. There was improvement in the specificity of the radioisotopic research showing specificity values larger than those found in literature. These method contributions were effective
207

Comparação entre as modalidades de isquemia renal isotérmica seletiva, não-seletiva e intermitente em coelhos / Comparison among modalities of normothermic renal ischemia selective, non-selective and intermittent in rabbits

Formiga, Cipriano da Cruz 08 July 2011 (has links)
INTRODUÇÃO: O limite de tempo de isquemia renal sem causar um dano permanente à função ainda é um questionamento pertinente na prática cirúrgica urológica. Algumas cirurgias requerem um campo cirúrgico menos sangrante, necessitando de uma interrupção temporária do fluxo sanguíneo para o parênquima renal através de clampeamento do pedículo. Este estudo objetivou avaliar qual técnica de clampeamento em isquemia isotérmica é superior, em termos de preservação da função renal. MÉTODOS: Neste estudo, foram utilizados 28 coelhos da raça New Zealand distribuídos em quatro grupos de forma randomizada e submetidos à laparotomia com interrupção do fluxo sanguíneo renal esquerdo, conforme grupo: grupo 1 - Controle, sem isquemia (4 animais), grupo 2 - Isquemia seletiva (8 animais), grupo 3 - Isquemia não-seletiva (8 animais) e grupo 4 - Isquemia não-seletiva intermitente (8 animais). Os animais foram submetidos à análises cintilográficas da função renal com mercaptoacetiltriglicina (MAG3) e dosagens séricas de creatinina no pré-operatório, no primeiro, terceiro e sétimo dias pós-operatórios. Após 15 dias da cirurgia, os animais foram sacrificados e os rins submetidos à análise histológica. RESULTADOS: A análise cintilográfica da função renal mostrou que os três grupos submetidos à isquemia apresentaram um agravo semelhante, nas primeiras 24 horas; não havendo diferença estatística entre eles no tocante a perda de função renal do rim esquerdo (p= 0,165), neste período. No exame do terceiro dia pós-operatório, houve diferença estatística (p= 0,006) entre os grupos não-seletivo (3) e o intermitente (4), mostrando uma superioridade do fator desclampeamento na proteção à função renal. No sétimo dia pós-operatório, o grupo do clampeamento seletivo (2) mostrou-se superior (p< 0,001) ao grupo não-seletivo (3), mas não apresentou diferença estatística em relação ao grupo intermitente (4). Este último, por sua vez, também apresentou-se superior ao grupo 3, com diferença estatística (p< 0,001). Após sete dias não foi observada diferença estatística entre os grupos 2 e 4. A histologia e a creatinina não mostraram diferença estatisticamente significante entre os grupos isquêmicos. Do ponto de vista funcional, a isquemia seletiva e a intermitente foram superiores em relação a não-seletiva. CONCLUSÃO: O modelo utilizado neste estudo mostrou uma superioridade da isquemia isotérmica seletiva e da intermitente em relação a não-seletiva na proteção da função renal. Não houve diferença entre o clampeamento seletivo e o intermitente não-seletivo na função do rim / INTRODUCTION: The time limit of renal ischemia with no permanent damage to renal function still remains as a pertinent question in urologic surgical practice. Several procedures require a bloodless surgical field most of time needing an interruption of blood flow to the renal parenchyma and they can require hilum control and clamping. This study assessed which normothermic clamping technique is superior in order to preserve kidney function. METHODS: In this project, 28 New Zealand rabbits were distributed in four groups by randomization and submitted to laparotomy and blood flow interruption of left kidney: Group 1 - Control, no ischemia (four animals), Group 2 Selective ischemia (eight animals), Group 3 Nonselective ischemia (eight animals) e Group 4 intermittent nonselective ischemia (eight animals). The animals were submitted to renal scintigraphy with mercaptoacetiltriglicin (MAG3) and serum creatinine analysis preoperatively and at days 1, 3 and 7 after left hilum clamping. The animals were submitted to nephrectomy and immediately sacrificed and the kidneys subjected to blinded evaluation by a nephropathologist. RESULTS: Renal scintigraphy showed equal damage in the three groups in first 24 hours, with no statistical difference in loss of left kidney function (p= 0,165) in this period. At third day examination, there was statistical difference (p= 0,006) between the nonselective group (3) and intermittent one (4), demonstrating a superiority of declamping factor in renal function protection. At seventh postoperative day, selective group (2) proved to be better (p< 0,001) than nonselective one (3), however there was not statistical difference between group 2 and the intermittent group (4). The intermittent clamping group was also superior to group 3 (p< 0,001). Histopathology and serum creatinine did not demonstrate statistical difference among groups. Functionally, selective and intermittent warm ischemia techniques are better than nonselective one. CONCLUSION: The model used in this study presented a superiority of selective clamping and intermittent arteriovenous clamping in shielding the renal function. No difference occurred between selective clamping and intermittent nonselective one
208

"Definição de conduta na investigação de doença coronária obstrutiva utilizando teoria de conjuntos fuzzy aplicada a dados clínico-epidemiológicos, ergométricos e cintilográficos" / Establishment of diagnostic procedures for coronary artery disease based on fuzzy set theory applied to clinical epidemiological data and treadmill electrocardiography and myocardial perfusion scintigraphy results.

Duarte, Paulo Schiavom 05 November 2004 (has links)
A doença arterial coronária (DAC) é uma das principais causas de morte no mundo. A detecção precoce é importante para prevenir este tipo de ocorrência. O método considerado padrão ouro para avaliar obstruções parciais críticas é a cinecoronariografia, uma técnica invasiva, trabalhosa e cara. Existem métodos não invasivos que podem ser utilizados para estabelecer este diagnóstico. A base do diagnóstico não invasivo da DAC tem sido a análise seqüencial dos fatores de risco e dos resultados do teste ergométrico e da cintilografia de perfusão do miocárdio. Muitos pesquisadores demonstraram que a utilização diagnóstica apropriada da cintilografia de perfusão do miocárdio e da cinecoronariografia é naqueles pacientes que têm probabilidade intermediária e alta para DAC, respectivamente. Apesar desta informação ser útil, ela é utilizada de forma limitada na prática clínica, devido à dificuldade em classificar apropriadamente os pacientes. Desde os artigos pioneiros de Lotfi A. Zadeh, a lógica fuzzy tem sido aplicada em diversas áreas. Ela é especialmente útil nas aplicações médicas, uma vez que as informações utilizadas no processo de decisão são incertas. Neste trabalho, foram desenvolvidos e testados modelos baseados na teoria de conjuntos fuzzy, para selecionar os pacientes que devem ser submetidos a cintilografia de perfusão do miocárdio e a cinecoronariografia. Utilizou-se grupo de 1053 pacientes para desenvolver os modelos e outro de 1045 para testá-los. Comparou-se o desempenho dos modelos com o de médicos especialistas utilizando-se curvas ROC e observou-se que os modelos fuzzy têm desempenho igual ou superior a estes especialistas na seleção dos pacientes que devem ser submetidos a cintilografia e cinecoronariografia, podendo, portanto, ser de grande auxílio ao médico na realização desta tarefa. / Coronary artery disease (CAD) is a worldwide leading cause of death. Early detection is important to prevent such sort of outcome. The gold standard method for evaluating critical partial occlusions is coronary arteriography, a catheterization technique which is invasive, time consuming, and costly. There are noninvasive approaches for early detection of CAD. The basis for the noninvasive diagnosis of CAD has been laid in a sequential analysis of the risk factors, and the results of treadmill electrocardiography and myocardial perfusion scintigraphy. Many investigators have demonstrated that appropriate diagnostic applications of myocardial perfusion scintigraphy and coronary arteriography are in patients who have an intermediate and a high likelihood of disease, respectively. Although this information is useful, it is only partially utilized in the clinical practice due to the difficulty to properly classify the patients. Since the seminal article by Lotfi A. Zadeh fuzzy logic has been applied in numerous areas. It is especially suited to medical applications, since much of the information required for decision-making is uncertain. In this paper, we proposed and tested models to select patients that have to undergo myocardial perfusion scintigraphy and coronary arteriography based on fuzzy set theory. It was used a group of 1053 patients to develop the models and another one of 1045 patients to test them. It was utilized ROC curves to compare the performance of the models with the ones of experts’ physicians and it was observed that the fuzzy models have a performance equal or superior to the experts in the selection of the patients that should perform scintigraphy and coronary arteriography, therefore, they could be a useful tool to assist the general practitioner in this task.
209

"Valor disgnóstico e prognóstico dos métodos de imagem na fratura de estresse da tíbia: correlação clínico-radiológica" / Diagnostic and prognostic value of image methods in tibia stress fractures : clinical-radiological correlation

Castropil, Wagner 08 June 2006 (has links)
Um grande problema em atletas com fraturas por estresse é o tempo necessário para sua recuperação completa. Nenhum método de imagem tem se mostrado eficaz em apresentar dados objetivos com relação ao tempo de recuperação dos atletas em casos de fraturas por estresse. Dois grupos foram incluídos no nosso estudo: grupo I consistente de 21 atletas com suspeita clínica de fratura de estresse (13 masculinos, idade média de 31,62 &#61617; 9,39) e grupo II consistente de 10 atletas sem sinais clínicos de fraturas de estresse (grupo controle) (seis masculinos, idade média 29,80 &#61617; 3,94). Todos os indivíduos do grupo I tiveram seguimento mínimo de seis meses e foram submetidos ao mesmo protocolo de reabilitação. Todos os atletas foram submetidos à ressonância magnética e cintilografia óssea com intervalo, entre os exames, inferior a sete dias. Um índice quantitativo foi obtido utilizando a técnica de ROI, comparando o lado afetado com o contralateral não afetado. Esta análise quantitativa foi comparada à análise semiquantitativa da ressonância magnética. Ambos os métodos mostraram 100% de sensibilidade; entretanto, sinais inespecíficos foram encontrados em 40% dos atletas assintomáticos na ressonância magnética e na cintilografia óssea. A média de captação de MDP-Tc99m na perna sintomática foi estatisticamente diferente no grupo I (2,54 &#61617; 0,77) em comparação ao grupo II (1,05 &#61617; 0,11) (p < 0,001). Um índice de 1,30 foi considerado ponto crítico onde 99% dos atletas apresentarão diagnóstico de fratura de estresse. Uma equação de regressão foi obtida, associando o tempo de recuperação necessário para o atleta e o índice calculado. Na presente amostragem de pacientes, o índice obtido por meio da cintilografia óssea nos permite obter um método objetivo para estimar o apropriado tempo de recuperação após um diagnóstico de fratura por estresse da tíbia. Entretanto, mais estudos prospectivos, com maior amostragem, são necessários para comprovar nosso achado. / A major problem in athletes with stress fractures is the length of resting time required for complete recovery. No imaging tool has been capable of offering objective data regarding the appropriate recovery time in athletes with stress fractures. Two groups of athletes were included in our study: Group I consisted of 21 athletes with clinical suspicion of tibial stress fracture (13 male; mean age + SD: 31.62 + 9.39) and, Group II consisted of 10 athletes without clinical signs of stress fracture (control group) (6 male; mean age + SD: 29.80 + 3.94). All individuals of Group I had minimum 6 months of follow up and the symptoms were recorded according to the same rehabilitation protocol. All athletes underwent to bone scintigraphy and MRI, with a mean interval between them no longer than 7 days. A quantitative index was obtained using ROI technique, comparing the affected to the non affected leg. This quantitative analysis was compared to a semi quantitative evaluation of MRI findings). Both methods showed 100% sensitivity; however, non specific signs were found in 40% of asymptomatic athletes either by MRI or by bone scan. The mean uptake of MDP-Tc99m in affected limbs were statistically different in Group I (2.54 + 0.77) in comparison to Group II (1.05 + 0.11) (p<0.001). An index of 1.30 was considered a critical point where 99% of athletes will present the clinical diagnosis of tibial stress fracture. A regression equation was obtained associating the time of recovery required for each athlete with the uptake index calculated. In the present sample of athletes the uptake index obtained through bone scintigraphy allowed us to obtain an objective method to estimate the appropriate recovering time after the tibial stress fracture diagnosis. However, more prospective studies using larger samples are needed to prove that assumption.
210

Quantificação da carga isquêmica em pacientes com doença coronária avançada sintomática: comparação entre a perfusão miocárdica avaliada por ressonância magnética cardíaca e por cintilografia miocárdica / Ischemic burden in advanced coronary artery disease: comparison between myocardial perfusion by cardiovascular magnetic resonance and single-photon emission computed tomography

Leite, Thiago Nunes Pereira 16 August 2018 (has links)
Introdução: A quantificação da isquemia miocárdica é um dado de grande auxílio na tomada de decisões clínicas ou intervencionistas no tratamento da doença arterial coronária (DAC) avançada. Dentre os métodos disponíveis para esta finalidade, se destacam a cintilografia de perfusão miocárdica (CPM) e a ressonância magnética cardíaca (RMC), que além de fornecerem informações quanto à alteração de motilidade entre o estresse e o repouso, são capazes de analisar a perfusão miocárdica. Neste estudo, investigamos a correlação e a concordância entre esses dois métodos em pacientes com DAC sintomática e avançada. Métodos e Resultados: Cinquenta e três pacientes com DAC avançada (padrão obstrutivo triarterial) não elegíveis para revascularização completa devido à extensão e caráter difuso das lesões foram submetidos à RMC e à CPM. A maioria (57%) apresentava sintomas limitantes (angina CCS 3 ou 4). Na quantificação da carga isquêmica, o percentual de miocárdio isquêmico total (%Mioisquêmico) foi significativamente maior na RMC do que na CPM (25,3±13,7% vs. 20,5±13,5%, respectivamente; P = 0,02). A RMC identificou baixa carga isquêmica em apenas 15% dos pacientes, enquanto pela CPM 53% dos pacientes foram assim classificados. Foram encontradas correlações fracas entre os métodos para o %Miofixo, no %Mioestresse e %Mioisquêmico (coeficiente de Spearman variando de 0,06 a 0,54), assim como uma fraca concordância (kappa de 0,11 e bias elavado de 9,3 para %Mioisquêmico). De um total de 159 territórios coronarianos, 18 (11%) apresentaram grandes discordâncias (%Mioisquêmico pela CPM < 10% e > 20% pela RMC) em regiões do ventrículo esquerdo com alta probabilidade pré-teste de possuírem isquemia importante (miocárdio viável em território irrigado por artéria coronária ocluída cronicamente). Conclusão: A quantificação da carga isquêmica estresse-induzida avaliada pela CPM e pela RMC possui fraca correlação e concordância em pacientes com DAC avançada e complexa, com a RMC demonstrando uma maior carga isquêmica do ventrículo esquerdo, principalmente nas regiões com infarto prévio / Introduction: The quantification of myocardial ischemia is a key element in the decision-making process in patients with advanced coronary artery disease (CAD). Single-photon emission computed tomography (SPECT) and cardiovascular magnetic resonance (CMR) are non-invasive tools for myocardial perfusion assessment. We investigated the correlation and agreement between these two methods in patients with symptomatic and complex CAD. Methods and Results: Fifty-three patients with advanced CAD (multivessel obstructive disease) not eligible for complete revascularization due the extension and diffuseness of the disease underwent both CMR and SPECT. The majority (57%) presented limiting symptoms (angina CCS 3 or 4). The quantification of the ischemic burden revealed that the mean percentage of total ischemic myocardium (%Myoischemic) was significantly higher as assessed by CMR compared with by SPECT (25.3±13.7% vs. 20.5±13.5%, respectively; P = 0.02). There were no significant correlations between CMR and SPECT regarding %Myostress (r = 0.23, p = 0.09), fixed (r = 0.20, p = 0.14), or ischemic (r = 0.11, p = 0.44). While SPECT classified 28 patients (53%) as having low ischemic burden (%Myoischemic < 10%), CMR classified only 8 patients (15%) in this category. Poor correlations between the two methods were found for %Myostress, %Myoischemic, and %Myofixed (Spearman\'s rho ranging from 0.06 to 0.54), depicting also slight agreement (kappa of 0.11 and bias as high as 9.3% for %Myoischemic). On a per-segment-based analysis, 18 coronary territories (11%) of the total 159, presented highly disagreements (%Myoischemic by SPECT < 10% and > 20% by CMR) in LV regions likely to have severe ischemia (viable myocardium supplied by chronically occluded vessels. Conclusion: The quantification of inducible myocardial ischemia by SPECT and CMR disagrees in patients with advanced and complex CAD, with CMR displaying greater left ventricular ischemic burden, particularly in patients with a previous myocardial infarction

Page generated in 0.0573 seconds