• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 135
  • 6
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 143
  • 110
  • 109
  • 85
  • 85
  • 78
  • 76
  • 57
  • 52
  • 50
  • 45
  • 42
  • 26
  • 24
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo de estimulação eletrica para controle aferente de dores cronicas

Binseng, Wang, 1950- 14 July 2018 (has links)
Orientador : Maria Adelia C. Farias / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-14T07:11:39Z (GMT). No. of bitstreams: 1 Binseng_Wang_M.pdf: 1873326 bytes, checksum: 90f493066dce071d025b34e547eeffa2 (MD5) Previous issue date: 1974 / Resumo: O tratamento de dores crônicas tem desafiado a Medicina durante séculos. As cirurgias de secção de tractos nervosos, além dos riscos inerentes, demonstraram ser pouco eficientes, e os resultados obtidos são inconstantes. Enquanto que as drogas analgésicas têm tendência de viciar o paciente. Foi projetado e construído um "Estimulador Neural" para estimular seletivamente os nervos periféricos grossos, a fim de inibir a sensação dolorosa pelo mecanismo de "Controle por Comporta" proposto por Melzack & Wall. Os resultados clínicos obtidos demonstram a eficiência da utilização da estimulação elétrica para o controle aferente da dor, sem necessidade de cirurgia e drogas viciantes / Abstract: The treatment of chronic intractable pain has been studied for many years. Surgical lesions or sections of nerve tracts, be sides the inherent surgical and psychological risks, proved to be inefficient and the results are unpredictable. The use of drugs has the problem of addiction, making it not recommended for long application. Term Physiological studies allowed us to design a "Neural Stimulator" for selective transcutaneous stimulation of the large nerve fibers to inhibit the pain by the mechanism proposed in the "Gate Control Theory" of pain by Melzack & Wall in 1965. The clinical results proved the efficiency of the utili¬zation of electrical stimulation for the afferent control of pain, without the necessity of surgeries and addicting drugs / Mestrado / Mestre em Automação
22

Metodologia para definição de sequencias de estimulação eletrica neuromuscular : aplicação a superação de pequenos obstaculos

Fasolo Quevedo, Antonio Augusto, 1970- 31 July 1996 (has links)
Orientador: Alberto Cliquet Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e Computação / Made available in DSpace on 2018-08-04T02:21:08Z (GMT). No. of bitstreams: 1 FasoloQuevedo_AntonioAugusto_D.pdf: 7763750 bytes, checksum: be936c1cdcf953886a91ca822c1326e8 (MD5) Previous issue date: 1996 / Resumo: A Estimulação Elétrica Neuromuscular (EE"NM) é uma ferramenta importante na pesquisa da reabilitação de movimentos perdidos em indivíduos portadores de lesão medular. A restauração da locomoção em paraplégicos e tetraplégicos é hoje a sua principal aplicação Para que a EENM possa ser utilizada de modo prático nesta restauração, entretanto, é necessário que o sistema de controle de estimulação seja capaz de lidar com condições adversas do ambiente, como terrenos irregulares, inclinações, degraus e obstáculos No presente trabalho, apresenta-se uma metodologia para a conversão de qualquer tarefa motora específica usada por indivíduos normais para lidar com uma destas condições em um algoritmo de controle para EENM. O trabalho apresenta esta metodologia, passo a passo, aplicada à produção de uma seqüência de estímulos que permite ao lesado medular superar pequenos obstáculos. Simulações comprovando a validade do método são discutidas, e experimentação clinica é apresentada. Neste trabalho, mostra-se ainda que a conversão da tarefa motora em questão feita sob análise cinemática apresenta melhores resultados que aquela referente a atividade muscular / Abstract: Neuromuscular Electrical Stimulation (NMES) is an important tool for research in the rehabilitation of lost movements in spinal patients. Its main application today is the restoration of locomotion in paraplegics and tetraplegias. However, for NMES to be used outside the laboratory setup, the stimulation controller needs to be able to cope with challenging environmental conditions, like uneven terrains, inclinations, steps, and obstacles. In this work, a methodology to allow conversion of any specific motor task used for coping with one of these enviromemal conditions to a control algorithm for NMES is presented. This methodology is shown, step by step, applied to the design of a stimulation sequence that allows the overcoming of small obstacles by the spinal patient. Simulations proving the method feasibility are discussed, and clinical trials are presented. In this work, it is also shown that the motor task conversion using the kinematic approach has better results than that of muscle activity view / Doutorado / Engenharia Biomedica / Doutor em Engenharia Elétrica
23

Sistema nanoestruturado lipossomal contendo chalcona CH8 para o tratamento da leishmaniose cutanea / Liposomal nanoestruturated system containing chalcone CH8 for the cutaneous leishmaniasis treatment

Silveira, Beatriz Zanchetta, 1982- 14 August 2018 (has links)
Orientador: Maria Helena Andrade Santana / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-14T09:51:17Z (GMT). No. of bitstreams: 1 Silveira_BeatrizZanchetta_M.pdf: 8346831 bytes, checksum: e0ef805cafa3599b49c6d357c8849853 (MD5) Previous issue date: 2009 / Resumo: Atualmente, os lipossomas elásticos têm se destacado em relação aos lipossomas convencionais (LC), pela capacidade de atingir as camadas mais profundas da pele. Neste trabalho, lipossomas elásticos foram preparados e caracterizados quanto às suas propriedades físico-químicas, de permeação in vitro e ex vivo, e aplicados ao tratamento tópico da leishmaniose cutânea. Estes lipossomas foram compostos de lecitina de ovo, e tiveram a sua superfície modificada pela incorporação do tensoativo PEG:8L, formando os lipossomas peguilados (LP). O fármaco encapsulado foi uma chálcona sintética nitrogenada (CH8), que vem se destacando como substância antiprotozoária e apresenta dificuldade de permeação através da pele. Os resultados obtidos mostram que o PEG-8L é incorporado na bicamada lipídica dos LC, produzindo maior fluidez e elasticidade. A incorporação do PEG-8L também modifica a tensão superficial e o potencial zeta dos LC. A encapsulação da CH8 foi verificada em ambos os casos (LC e LP), com modificações na morfologia, diâmetro médio, tensão superficial e temperatura de transição de fase em relação aos LC vazios. Os estudos de permeação em membranas sintéticas de nanoporos (in vitro) mostraram que os LP possuem maior capacidade de permeação que os LC, e que a CH8 produz elasticidade aos LC aumentando sua capacidade de permeação em relação aos LP contendo CH8. Os estudos de permeação em pele de orelha de porco (ex vivo) mostraram que a CH8, em ambos os tipos de lipossomas, foi capaz de permear as camadas da pele e atingir a derme. Os resultados in vivo no tratamento da leishmaniose em camundongos mostraram que as formulações lipossomais foram mais eficientes que a CH8 livre, destacando-se a eficácia da CH8 em LC, cuja ação foi semelhante à aplicação da CH8 livre intralesional. Os resultados obtidos mostram o desenvolvimento tecnológico da preparação de LC e LP contendo CH8, e contribuem para o tratamento mais eficaz da leishmaniose cutânea. / Abstract: Nowadays, elastic liposome (EL), has gained attention when compared with conventional liposome (CL), by its capacity of reach the skin's deepest layers. In this work, elastic liposome were prepared and characterized by its physic-chemical properties, in vivo and ex vivo permeation, and its application for cutaneous leishimania topical treatment. The liposome was composed by egg lecithin, and had it surface modified by the incorporation of PEG-8L tensoactive, forming PEGylated liposome (PL). The encapsulated drug was a synthetic nitrogened chalcone (CH8), which has aroused as anti-protozoa substance and presents difficult permeation through the skin. Results obtained shows that PEG-8L was incorporated on LC's lipid bilayer, producing enhanced elasticity and fluidity. PEG- 8L incorporation also modifies the superficial tension and zeta's potencial of the CL. CH8's encapsulation was observed in both cases, presenting modification at morphology, mean diameter, superficial tension and phase transition's temperature when related with empty CL. The permeation studies in synthetic nanopores' membranes (in vitro) showed that PL has higher permeation capacity than CLf and CH8 produced some elasticity to CL increasing its permeation capacity even when related to PL containing CH8. The pig's ear skin permeation studies (ex vivo) showed that CH8 in both liposome types was capable of permeate the skin layers, reaching the dermis. Mice leishimania treatment in vivo results showed that the liposomal formulation was more efficient that free CH8, underling CH8's efficiency in CL, in which the action was similar to free CH8 intra-wound application. Results showed the technological development of CL and PL containing CH8 that contribute to a more efficiency treatment of coetaneous leishmania. / Mestrado / Desenvolvimento de Processos Biotecnologicos / Mestre em Engenharia Química
24

Avaliação de formulações vacinais anti-dengue administradas pela via transcutânea visando à geração de anticorpos neutralizantes. / Evaluation of anti-dengue vaccine formulations administered by the transcutaneous route aiming the generation of neutralizing antibodies.

Santos, Robert Andreata 23 March 2017 (has links)
A dengue é uma arbovirose que ameaça mais de metade da população mundial. No momento existem duas vacinas, administradas por vias parenterais, aprovada ou em estudos clínicos, que podem conferir proteção parcial em regiões endêmicas, mas que ainda não estão sendo administradas em larga escala. Por outro lado, a utilização de vias de administração alternativas, como a via transcutânea (TC), pode ter um impacto importante na eficácia vacinal. A entrega de formulações vacinais pela via TC tem como vantagem a administração segura e não invasiva de antígenos vacinais e a composição celular específica da pele, rica em células apresentadoras de antígenos, como as células de Langerhans; O presente estudo demonstra que a via TC pode induzir respostas sorológicas vírus-específicas de forma eficiente quando utilizada para a administração de vacinas contra DENV baseadas em partículas virais. Portanto, novos estudos devem ser feitos considerando a TC como uma via de administração alternativa às vias parenterais para a administração de vacinas contra a dengue. / Dengue is an arbovirosis that threatens more than half the world\'s population. Currently there are two vaccines, both administered via parenteral routes, approved or in clinical trials, which provide partial protection but are not being administered on a large scale. On the other hand, the use of alternative routes of administration, such as the transcutaneous (TC) route, can have a significant impact on vaccine efficacy. Delivery of vaccine formulations via the TC route has the advantage of a safe and non-invasive administration method of vaccine antigens through the skin, that has a cell composition rich in antigen-presenting cells, such as the Langerhans cells. The present study demonstrates that the TC route can efficiently induce virus-specific serological responses when used for administration of DENV vaccines based on viral particles. Further studies should explore different dengue vaccines using the TC route as an alternative to parenteral administration routes.
25

Estimulação elétrica transcutânea do nervo: analgesia preemptiva em colecistectomia por laparotomia / Transcutaneous Electrical Nerve Stimulation: preemptive analgesia in open cholecystectomy.

Guerra, Danilo Ribeiro 13 December 2005 (has links)
O uso da Estimulação Elétrica Transcutânea do Nervo (TENS) vem sendo muito pesquisado em pós-operatórios, todavia os estudos não analisam se a TENS de baixa freqüência -- que estimula a liberação de opióides endógenos -- seria eficiente em promover analgesia preemptiva. Objetivo. Analisar se essa modalidade de TENS, aplicada antes de colecistectomias por laparotomia, poderia proporcionar analgesia preemptiva. Casuística e método. A pesquisa -- clínica, controlada, randomizada e duplamente encoberta -- foi realizada no Hospital São Domingos Sávio, e teve uma amostra de 50 pacientes, todas do sexo feminino: grupo preemptivo (n = 25) e placebo (n = 25). As pacientes do primeiro grupo foram submetidas à aplicação da TENS de baixa freqüência antes da cirurgia: e as do grupo placebo, a uma falsa estimulação. Houve a padronização do cloridrato de bupivacaína (0,5%) como droga anestésica, associado ao fentanil (2 ml) para a realização das colecistectomias; e da medicação analgésica utilizada no pós-operatório: dipirona, prescrita de 6 em 6 horas, e diclofenaco de sódio, como medicação de resgate. A intensidade de dor pós-operatória foi mensurada pela Escala Numérica de Mensuração da Dor (END), em 8 momentos (2½, 3½, 4½, 5½, 7, 8 e 16 horas após a indução do bloqueio anestésico, além de uma última verificação no momento da alta hospitalar), e pelo Questionário de Dor McGill (MPQ), aplicado 16 horas após a indução do bloqueio anestésico. Outrossim, o grau de satisfação das pacientes com o tratamento foi mensurado pela Escala de Satisfação do Paciente (ESP). Os dados foram analisados por meio de testes estatísticos descritivos, Teste de Mann-Whitney, Teste-t de Student para amostras não-pareadas e qui-quadrado, sendo o nível de significância de 5%. Resultados. A intensidade de dor, mensurada pela END, foi significantemente menor no grupo preemptivo nas terceira e quarta coletas. Não houve diferença significante quanto aos índices obtidos pelo MPQ, e nem quanto à satisfação das pacientes, o consumo de drogas analgésicas no pós-operatório e o tempo para o primeiro requerimento de diclofenaco de sódio. Conclusão. A TENS de baixa freqüência proporcionou analgesia preemptiva após colecistectomia por laparotomia. / Introduction. Transcutaneous Electrical Nerve Stimulation (TENS) has been searched in the postoperative period, however these studies don\'t analyze whether low frequency TENS -- that stimulates the release of endogenous opioids -- could be efficient to provide preemptive analgesia. Objective. The aim of this study was to verify whether low frequency TENS, applied before open cholecystectomies, could provide it. Cases and method. It was a controlled, randomized and double-blinded trial, carried out at the Hospital São Domingos Sávio (Aracaju city, Brazil), and had a sample of 50 patients: preemptive group (n = 25) and placebo (n = 25). The patients from the first group were submitted to the application of TENS before the surgery; and the placebo group to a false stimulation. There was the standardization of the bupivacaine (0,5 %) as anesthetic drug plus fentanyl (2 ml) for the accomplishment of the cholecystectomies; and of the analgesic medication used in the postoperative period: dipyrone, prescribed for every 6 hours, and diclofenac, only if the patients complained about pain. Pain intensity was measured by the Numerical Rating Scale (NRS), in 8 moments (2½, 3½, 4½, 5½, 7, 8 e 16 hours after inducing the anesthesia besides one last verification at the hospital discharge), and by the Brazilian version of the McGill Pain Questionnaire (Br-MPQ), applied 16 hours after inducing the anesthesia. Patient satisfaction level in relation to the treatment was measured by the Patient Satisfaction Scale (PSS). The data were analyzed by Mann-Whitney Test, unpaired t-test and qui-square, being significant, those data with p < 0,05. Results. Pain intensity, measured by the NRS, was lower in the preemptive group in the third and fourth verifications. There was no difference neither in relation to the indexes obtained with the Br-MPQ, nor the PSS, consume of analgesics in the postoperative and time for the first request of diclofenac. Conclusion. Low frequency TENS provided preemptive analgesia after open cholecystectomy.
26

Influência da iontoforese na imunização transcutânea utilizando lipossomas e nanopartículas metálicas / Iontophoresis influence on transcutaneous immunization using liposomes and metal nanoparticle

Bernardi, Daniela Spuri 24 September 2015 (has links)
A imunização transcutânea (IT) é uma técnica promissora de vacinação, na qual a formulação contendo o antígeno é aplicada sobre a pele para induzir resposta imune. O sucesso desse tipo de imunização ocorre devido à presença de células apresentadoras de antígenos (APCs) na epiderme viável, as quais são potentes estimuladoras de linfócitos T. Porém, é necessário que o antígeno transponha a barreira imposta pelo estrato córneo e atinja a epiderme viável em concentrações adequadas para que uma resposta imune efetiva seja induzida. Neste trabalho, a influência da iontoforese, método físico que utiliza uma corrente elétrica fraca para aumentar a penetração cutânea de fármacos, foi investigada pela primeira vez na IT. Sua associação com lipossomas, para direcionar a liberação do antígeno para a epiderme viável, e com nanopartículas de prata (NPAg), para potencializar a resposta imune, também foi avaliada pela primeira vez. A ovalbumina (OVA) foi utilizada como antígeno modelo e a injeção subcutânea de OVA como controle positivo da imunização. Foram obtidos lipossomas aniônicos contendo 5 mg/mL de OVA e catiônicos contendo 0,25 mg/mL de OVA, adicionados ou não de NPAg. Os lipossomas aniônicos apresentaram tamanho médio de aproximadamente 120 nm e eficiência de encapsulação da OVA de 78,4%. Os lipossomas catiônicos apresentaram tamanho médio de aproximadamente 260 nm e eficiência de encapsulação da OVA de 83,08%. A adição das NPAg não alterou significativamente o tamanho dos lipossomas, mas alterou o potencial zeta (de -7,5 mV para -14 mV para os lipossomas aniônicos e de +41 mV para +36 mV para os lipossomas catiônicos). As microscopias de força atômica e eletrônica de transmissão (MET) confirmaram a presença de vesículas lipossomais, sendo que a TEM mostrou as NPAgs dispersas no meio aquoso externo dos lipossomas aniônicos e no meio aquoso interno dos lipossomas catiônicos. A OVA e os lipossomas se mostraram estáveis ao processo de obtenção e frente a corrente elétrica. Nos estudos de penetração cutânea in vitro observou-se que a encapsulação da OVA nos lipossomas direcionou sua liberação para a epiderme viável. A associação com a iontoforese aumentou 108 vezes a liberação da OVA na epiderme viável quando lipossomas aniônicos contendo NPAg foram administrados e 92 vezes quando lipossomas catiônicos contendo NPAg foram administrados. A presença das NPAg nas formulações aumentou a quantidade de OVA na epiderme viável quando a iontoforese foi utilizada, mas diminuiu sua penetração passiva. As quantidades de OVA penetradas por iontoforese anódica e catódica a partir dos lipossomas aniônicos não foram significativamente diferentes. O coeficiente de penetração da OVA na epiderme viável a partir da iontoforese dos lipossomas aniônicos foi 1,6 vezes (na ausência de NPAg) e 39 vezes (na presença de NPAg) maior do que o dos lipossomas catiônicos. Nos experimentos de imunização transcutânea in vivo observou-se que as quantidades de OVA que penetraram a pele por iontoforese foram suficientes para induzir resposta imune humoral semelhante a induzida pela injeção subcutânea da OVA para os lipossomas aniônicos, na presença e ausência de NPAg, e para o lipossoma catiônico apenas na presença da NPAg, sugerindo que as NPAg, na presença de baixas concentrações de OVA, funcionam como adjuvantes imunológicos. A iontoforese anódica das formulações, assim como a injeção subcutânea da OVA, não estimularam resposta imune celular significativa. A iontoforese catódica, no entanto, induziu tanto resposta humoral como celular, além de estimular a produção de INF-? e o recrutamento de células apresentadoras de antígeno, tanto no baço como nos linfonodos inguinais. Sendo assim, a iontoforese de lipossomas contendo OVA e NPAg foi capaz de direcionar a liberação da OVA para a epiderme, induzir altos títulos de anticorpos IgG1 e ainda ativar a resposta imune celular, sendo uma estratégia promissora para a IT. / Transcutaneous immunization (TI) is a promising strategy for vaccine in which the antigen-containing formulation is applied to the skin to induce immune response. The success of this type of immunization occurs due to the presence of antigen presenting cells (APCs) in the viable epidermis, which are potent stimulator of T lymphocytes. However, the antigen should transpose the barrier imposed by the stratum corneum to reach the viable epidermis in appropriate concentrations so that an effective immune response is induced. In this work, the influence of iontophoresis, a physical method that uses a weak electrical current to increase skin penetration of drugs, was investigated for the first time in TI. Its association with liposomes, to target the antigen release to the viable epidermis, and with silver nanoparticles (NPAg), to enhance the immune response, was also evaluated for the first time. Ovalbumin (OVA) was used as a model antigen and OVA subcutaneous injection as a positive control of immunization. Anionic and cationic liposomes containing 5 mg/ml and 0.25 mg/mL of OVA, respectively, were obtained and were added or not by NPAg. Anionic liposomes had an average size of approximately 120 nm and 78,4% OVA encapsulation efficiency. Cationic liposomes had an average size of approximately 260 nm and 83,08% OVA encapsulation efficiency. The addition of NPAg did not significantly alter the size of the liposomes, but changed the zeta potential (-7.5 mV to - 14 mV for anionic liposomes and +41 mV to +36 mV for cationic liposomes). The atomic force microscopy and transmission electron microscopy (TEM) confirmed the presence of liposomal vesicles; TEM showed NPAgs dispersed in the external aqueous medium of the anionic liposomes and in the internal aqueous medium of the cationic liposomes. The OVA and the liposomes were stable during the preparation process and in front of the electric current. In the in vitro skin penetration studies it was observed that the encapsulation of OVA into liposomes directed their release to the viable epidermis. The association with iontophoresis increased 108-fold the release of OVA in the viable epidermis when anionic liposomes containing NPAg were administered and 92-fold when cationic liposomes containing NPAg were administered. The presence of NPAg in the formulations increased the amount of OVA released in the viable epidermis when iontophoresis was applied, but decreased OVA passive penetration. The amount of OVA penetrated by anodic and cathodic iontophoresis of anionic liposomes was similar. The OVA penetration coefficient in the viable epidermis from the iontophoresis of anionic liposomes was 1.6-fold (in the absence of NPAg) and 39- fold (in the presence of NPAg) greater than the iontophoresis of cationic liposomes. In transcutaneous immunization in vivo experiments, it was observed that the amount of OVA that penetrated the skin by iontophoresis was sufficient to induce similar humoral immune response than that induced by subcutaneous injection of OVA when anionic liposomes, in the presence and absence of NPAg, and cationic liposome, only in the presence of NPAg, were administered. These results suggest that NPAg in the presence of low concentrations of OVA acted as immunological adjuvants. Altough induced humoral immune response; anodal iontophoresis of the formulations as well as subcutaneous injection of OVA did not stimulate significant cellular immune response. Cathodic iontophoresis, on the other hand, induced both humoral and cellular immune response, as well as stimulating the production of IFN-? and the recruitment of antigen presenting cells, both in spleen and in inguinal lymph nodes. Therefore, iontophoresis of liposomes containing OVA and NPAg was able to target the release of OVA to the epidermis, induce high titers of IgG1 and activate the cellular immune response, being a promising strategy for TI.
27

Análise crítica atual sobre a TENS envolvendo parâmetros de estimulação para o controle da dor. / The current critical analysis about TENS involving parameters of stimulation to control the pain.

Tribioli, Ricardo Alexandre 20 May 2003 (has links)
A estimulação elétrica nervosa transcutânea ou TENS (como é conhecida pela abreviação do inglês: Transcutaneous Electrical Nerve Stimulation), é uma valiosa técnica clínica não invasiva, onde estímulos elétricos são aplicados na superfície da pele, para promover o alívio sintomático da dor de diversas origens. Os mecanismos de ação e os parâmetros utilizados com essa técnica vem sendo pesquisados na tentativa de se obter os melhores resultados possíveis. A polêmica sobre o assunto atingiu proporções dignas de uma revisão sistemática, com abordagem das teorias envolvidas na modulação da dor pela TENS, evidências clínicas e fisiológicas mais discutidas. As pesquisas atuais sugerem que a TENS pode produzir analgesia por diferentes mecanismos, sendo que as evidências revelam a preferência de parâmetros preferenciais individuais como determinante para o sucesso no tratamento da dor. / Transcutaneous electrical nerve stimulation or TENS is a valuable clinical technique no invasive, where electrical stimulus are applied on the skin surface to foment the symptomatic relief of pain from several origins. The action mechanisms and the parameters used with this technique are being researched on attempt to obtain the best results as possible. The polemics about the subject reached proportions deserved for a systematical review, with approaches of theories involved on pain modulation by TENS, clinical evidences and physiological more discussed the current surveys suggest that TENS may produce analgesia for different mechanisms, being that evidences reveal the preference of individual parameters as determinant for success on treatment of pain.
28

Efeito da eletroestimulação nervosa transcutânea de alta e baixa frequência no alívio da dor de puérperas pós-episiotomia: estudo clínico, randomizado e duplo cego / Effect of high and low frequency transcutaneous electrical nerve stimulation in postpartum pain relief after episiotomy: a clinical, randomized and double blind study

Araujo, Ana Carolina Rodarti Pitangui de 12 July 2011 (has links)
A Eletroestimulação nervosa transcutânea (TENS) é um recurso não invasivo que tem como principal finalidade o alívio da dor. A dor perineal pós-episiotomia é uma queixa frequente no puerpério que pode interferir em diversas atividades diárias das puérperas. O objetivo deste estudo foi avaliar o efeito da TENS de alta e baixa frequência no alívio da dor de puérperas pós-episiotomia. Trata-se de um estudo clínico, randomizado, controlado e duplo cego com placebo, composto por 32 puérperas submetidas ao parto normal com episiotomia. As participantes foram divididas em três grupos, TENS alta frequência (TAF), TENS baixa frequência (TBF) e TENS placebo (TP). Os eletrodos foram posicionados paralelamente, próximos a episiotomia, na região dos nervos pudendo e genitofemural. O grupo TAF recebeu frequência de 100 Hz e largura de pulso de 100 ?s e o grupo TBF recebeu frequência de 5 Hz com largura de pulso de 100 ?s. No grupo TP o aparelho permaneceu ligado, mas não emitiu estímulo elétrico. A duração da aplicação da TENS foi de 30 minutos. Inicialmente, foi preenchido o formulário de dados, composto pelas variáveis relacionadas à identificação das puérperas, dados sócio-demográficos, obstétricos, do trabalho de parto e parto atual, do recém-nascido e requisição e/ou consumo de recurso de alívio de dor. Foram realizadas quatro avaliações. A avaliação inicial ocorreu antes da TENS. As puérperas que referiram presença de dor na episiotomia responderam a escala visual numérica (EVN) na posição repouso e aos movimentos sentar e deambular. Na verificação da limitação funcional, as puérperas responderam questões referentes às atividades de vida diárias que estavam limitadas. A segunda avaliação foi iniciada imediatamente após a retirada da TENS, sendo aplicado a EVN nas mesmas atividades avaliadas anteriormente. Nos três grupos de estudo foi aplicado o instrumento da opinião da puérpera em relação ao uso da TENS. A terceira avaliação ocorreu após 30 minutos da retirada da TENS, houve nova avaliação da dor apenas para a posição repouso. A quarta avaliação foi realizada após se passarem 60 minutos da retirada da TENS, foi feita a última avaliação da dor na posição repouso. Na coleta de dados, um examinador ficou responsável pelas avaliações da dor e pelo preenchimento da ficha de avaliação e o outro pela aplicação da TENS. Foram utilizados testes estatísticos não paramétricos, com nível de significância de p <= 0.05. A análise descritiva foi usada para apresentação dos dados. Na análise intragrupo foi verificada nos grupos TAF e TBF diferença estatística significativa na intensidade da dor na posição repouso e nas atividades sentar e deambular, não houve diferença significativa nas avaliações analisadas no grupo TP. Nos resultados da análise intergrupo, houve diferença estatística significativa na posição repouso e sentar nos grupos TAF e TBF. Não foi verificada diferença estatística significativa entre os três grupos na atividade deambular. A TENS nas frequências alta e baixa demonstrou ser eficaz no alívio de dor das puérperas submetidas à episiotomia pós-parto normal, podendo ser utilizada na rotina das maternidades. / Transcutaneous electrical nerve stimulation (TENS) is a non-invasive method that has as main purpose the relief of pain. The perineal pain after episiotomy is a frequent complaint in the puerperium that can interfere in many daily activities of puerperae. The aim of this study was to evaluate the effect of high and low frequency TENS in postpartum pain relief after episiotomy. This is a clinical, randomized, controlled, double blind study with placebo, consisting of 32 puerperal women undergoing to vaginal delivery with episiotomy. The participants were divided into three groups, high frequency TENS (TAF), low frequency TENS (TBF) and TENS placebo (TP). The electrodes were placed parallel near episiotomy, in the region of the pudendal and genitofemoral nerves. The TAF group has received 100 Hz frequency and pulse width of 100 ?s and the TBF group received frequency of 5 Hz with pulse width of 100 ?s. In the TP group the device was connected but did not deliver the electrical stimulation. The duration of TENS application was 30 minutes. Initially, it was filled the form data\'s, composed of the variables related to the women\'s identification, data\'s socio-demographic, obstetric, labor and actual delivery, the newborn and request and/or consumption of pain relief resource. Four evaluations were done. The initial assessment occurred before TENS. The puerperae who reported pain in episiotomy responded the visual numeric scale (VNS) in the rest position and the movements sit and walk. In the verification of functional limitation, the puerperaes answered questions regarding the activities of daily living that were limited. The second evaluation was initiated immediately after removal TENS, being applied the EVN in the same activities previously assessed. In the three study groups was applied the instrument about the puerperae opinion regarding the use of TENS. The third assessment occurred 30 minutes after removal of TENS, there was a new pain assessment only for the rest position. The fourth assessment was carried out to pass 60 minutes from the removal of TENS, was done the latest assessment of pain in the rest position. In collecting data, one examiner was responsible by the assessment of pain and to completing the evaluation form and the other by application of TENS. It was used nonparametric statistics tests, with a significance level of p <= 0.05. Descriptive analysis was used for data presentation. In the intragroup analysis was observed in groups TAF and TBF statistically significant difference in pain intensity at rest position and activities sit and walk, no significant difference in the analyzed evaluations in the TP group. The results of the intergroup analysis, showed a statistically significant difference in resting position and sit in groups TAF and TBF. There isn\'t verified significantly different between the three groups in walking activity. TENS in the high and low frequencies has proven effective in relieving pain of the puerperae undergoing episiotomy after normal delivery, can be routinely used in the maternity routine.
29

Aplicacao do oximetro de pulso em recem-nascidos internados na unidade de terapia intensiva, no bercario e durante atendimento na sala de parto

Felix, Elaine Aparecida January 1994 (has links)
O oxímetro de pulso tornou-se o método de escolha para monitorização não invasiva da oxigenação em recém-nascidos (RN). Em geral, as publicações são favoráveis quanto à obtenção da saturação de oxigênio através das leituras do oxímetro (Sp02) dando ênfase às facilidades de aplicação do sensor, à baixa freqüência de complicações, respostas rápidas e contínuas da Sp02 frente a mudanças na oxigenação sangüínea; e ainda à boa correlação da Sp02 com medidas invasivas da saturação de oxigênio no sangue arterial (Sa02). No entanto, a aplicabilidade do oxímetro de pulso em neonatos tem sido melhor documentada em unidades de terapia intensiva sendo escassos os trabalhos realizados em RN sadios, imediatamente após o parto. Este trabalho focaliza três aspectos da aplicação do oxímetro de pulso em neonatos: inicialmente compara os valores da saturação de oxigênio calculada (Sa02cal) na análise de gases sangüíneos com medidas da Sp02 em 32 RN doentes; numa segunda etapa busca relacionar os valores de Sp02 ao processo de adaptação normal à vida extra-uterina em 45 RN dentro dos primeiros dez minutos após o parto e no berçário, em 57 recém-nascidos nas primeiras duas horas de vida. Finalmente, identifica os problemas técnicos e Limitações no uso clinico do oxímetro de pulso capazes de influenciar a interpretação dos resultados. A análise comparativa de 45 pares de medidas simultâneas de Sp02 e Sa02cal obtidas dos 32 RN internados na unidade de cuidados intensivos mostrou uma correlação de O, 77 (Sp02 = 62,5 + 0,36 Sa02cal) enquanto a média das diferenças entre os valores absolutos da Sp02 e Sa02cal (bias) encontrada foi de 3,5% e a precisão de 5,6%. As diferenças entre as medidas foram menores em níveis de saturação de oxigênio acima de 85%. Abaixo destes, as Sp02 superestimaram os valores da Sa02cal. Os registros contínuos das medidas da Sp02 obtidos na sala de parto demonstraram que os valores médios da Sp02 foram sempre mais baixos para os neonatos avaliados nos primeiros dez minutos de vida (< 90%). Logo após, no berçário, foi verificado um aumento progressivo dos valores de Sp02 que rapidamente atingiram níveis ao redor de 92,7% em menos de 30 minutos, 95,5% em cerca de 60 minutos, alcançando subseqüentemente o patamar de 97,2 %. Foi adotado um critério padrão para a seleção de medidas contínuas da Sp02 isentas de dados espúrios. A extrema sensibilidade do sensor do oxímetro ao movimento e a outros fatores de interferências invalidou a maioria dos registros em neonatos nos primeiros 5 minutos após o parto. Estes problemas foram de relevância menor no ambiente menos conturbado do berçário. Neste estudo, o oxímetro de pulso mostrou-se útil para detectar os graus de variação da saturação de 02 no sangue arterial, característicos do período neonatal. Em adição, permitiu medir a velocidade em que o nível normal é alcançado após o parto. No contexto geral, o estudo demonstrou as falhas inerentes ao emprego da técnica. O equipamento não parece ser confiável em níveis de Sa02cal baixos e a interposição de fatores que interferem com a captação do sinal - se não forem excluídos das análises - fornecem resultados inacurados. Estas limitações exigem cautela na interpretação dos dados de monitorização da oxigenação do neonato. / Pulse oximetry has become the method of choice for non-invasive monitoring of oxygenation in newbo rn infants. In general, the reports have been favourable regarding neonatal oxygen saturation from the oximeter readings (Sp02) with emphasis on the easy application of Sp02 probes, infrequency of cutaneous injury, rapiel and continuous response of Sp02 to changes in blooel oxygenation, anel gooel correlation of Sp02 with invasive oxygen saturations (Sa02). So far, the applicability of pulse oximetry in neonates has been mainly elocumenteel in intensive care units anel less in healthy infants, immediately after delivery. This work focuses on three aspects of pulse oximetry application in neonates: 1- in the comparison of calculateel oxygen saturation values (Sa02cal) with Sp02 in 32 critically ill infants; 2- in following the normal aelaptation to extrauterine life within 10 minutes of ele livery (n=45) anel then through the first two hours (n=57); 3- in the ielentification of the technical problems encountereel eluring its routine clinicai use anel the pitfalls in the interpretation of results. The comparative analysis of 45 pairs of simultaneously measureel Sp02 anel Sa02cal obtaineel from 32 infants in the intensive care unit showeel a correlation of 0,77 (Sp02 = 62,5 + 0,36 Sa02cal) while the mean of the absolute differences between Sp02 and Sa02cal values (bi::~s) was founel to be 3,5% anel precision of 5,6%. The elifferences betwen measurements were small er at saturations above 85%. Sp02 overestimateel Sa02cal when the values of Sa02cal were at lower leveis. The continuous recoreling of the Sp02 taken in the elelivery room demonstrateel that the mean values of Sp02 were alwalys lower for neonates in their first 10 minutes of life (below 90%). Shortly thereafter at the nursery a progressive elevation of Sp02 was rapidly accomplisheel with mean values arou nel 92,7% in less than 30 minutes, 95,5% within 60 minutes reaching subsequently a plateau of 97,2 %. Criteria for measu ring continuously the Sp02 output from the oximeter were stanelarelizeel in oreler to obtain artifact free data. The extreme sensitivity of the oximeter probe to movement anel other interference facto rs invalielateel most of the records from newborns five minutes after elelivery. These problems were consiclerably less relevant in the unelisturbeel environment of the nursery. In this s tucly, the pulse oximeter provecl useful to detect the degree of oxygen saturation of arteri al blood which characterizes the neonatal period, anel to measure the speed with which the normal levei is attained after de livery. The overall s tudy has also shown the drawbacks of the technique. The equipment seems not to be reliable at JQ\.ver Sa02cal values anel the interposition of interfering factors disturbing signal captation, if not exclucled from the analysis, give inaccurate results. These limitations encountered here in are meaningful in monitoring oxygenation o f neonates anel cal I for caution in the interpretation of data.
30

Ajuste autonômico e endotelial frente a eletroestimulação ganglionar em homens com insuficiência cardíaca chagásica : ensaio controlado e randomizado

Nakata, Cláudio Hiroshi, Nakata, Cláudio Hiroshi 26 July 2018 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ceilândia, Programa de Pós-Graduação Stricto Sensu em Ciências e Tecnologias e Saúde, 2018. / Tese (doutorado)—Universidade de Brasília, Faculdade de Ceilândia, Programa de Pós-Graduação Stricto Sensu em Ciências e Tecnologias e Saúde, 2018. / Introdução: A estimulação elétrica nervosa transcutânea (TENS) aplicada na região cérvico-torácica tem demonstrado capacidade de aumentar o fluxo sanguíneo periférico por meio da modulação autonômica em indivíduos saudáveis e isquemia vascular. Pacientes com insuficiência cardíaca de etiologia chagásica manifestam fibrose das fibras miocárdicas que induz uma sobrecarga autonômica compensatória. Nossa hipótese é que a EEG possa modular a hiperatividade simpática e melhorar a função vascular nessa população. Objetivos - Avaliar o efeito da estimulação elétrica nervosa transcutânea ganglionar na variabilidade da frequência cardíaca (VFC) e na dilatação mediada por fluxo (FMD) em homens com insuficiência cardíaca chagásica. Métodos: Foi realizado um ensaio clínico randomizado. Vinte homens (10 saudáveis e 10 chagásicos) foram submetidos a uma intervenção (TENS ou placebo) aplicada sobre a região ganglionar (vértebras C7 e T4) durante 30 minutos. A VFC e as imagens de fluxo sanguíneo e resistência vascular foram continuamente monitoradas durante as sete etapas do protocolo de coleta enquanto que as imagens da FMD foram registradas antes e após a intervenção durante os 5 minutos de liberação do manguito da oclusão da artéria braquial. Os efeitos da intervenção foram comparados utilizando-se o Teste ANOVA Two-way com Teste post-hoc de Tukey para ambos os grupos, considerando um p <0,05. Resultados: A FMD aumentou 69,93% nos indivíduos saudáveis (6,32 ± 2,39% para 10,74 ± 2,52%) e 28,45% em pacientes chagásicos (8,33 ± 2,44% para 10,7 ± 1,98%) após aplicação da TENS ganglionar. A VFC apresentou um padrão de redução da atividade simpática durante a modulação autonômica. Conclusão: Apesar de não alterar os índices da VFC, a aplicação da TENS sobre a região cérvico-torácica melhorou o ajuste da função endotelial da artéria braquial. Este resultado ratifica o efeito vascular da TENS aplicada sobre o gânglio estrelado e demonstra a capacidade preservada de dilatação dos vasos na insuficiência cardíaca chagásica. / Introdução: A estimulação elétrica nervosa transcutânea (TENS) aplicada na região cérvico-torácica tem demonstrado capacidade de aumentar o fluxo sanguíneo periférico por meio da modulação autonômica em indivíduos saudáveis e isquemia vascular. Pacientes com insuficiência cardíaca de etiologia chagásica manifestam fibrose das fibras miocárdicas que induz uma sobrecarga autonômica compensatória. Nossa hipótese é que a EEG possa modular a hiperatividade simpática e melhorar a função vascular nessa população. Objetivos - Avaliar o efeito da estimulação elétrica nervosa transcutânea ganglionar na variabilidade da frequência cardíaca (VFC) e na dilatação mediada por fluxo (FMD) em homens com insuficiência cardíaca chagásica. Métodos: Foi realizado um ensaio clínico randomizado. Vinte homens (10 saudáveis e 10 chagásicos) foram submetidos a uma intervenção (TENS ou placebo) aplicada sobre a região ganglionar (vértebras C7 e T4) durante 30 minutos. A VFC e as imagens de fluxo sanguíneo e resistência vascular foram continuamente monitoradas durante as sete etapas do protocolo de coleta enquanto que as imagens da FMD foram registradas antes e após a intervenção durante os 5 minutos de liberação do manguito da oclusão da artéria braquial. Os efeitos da intervenção foram comparados utilizando-se o Teste ANOVA Two-way com Teste post-hoc de Tukey para ambos os grupos, considerando um p <0,05. Resultados: A FMD aumentou 69,93% nos indivíduos saudáveis (6,32 ± 2,39% para 10,74 ± 2,52%) e 28,45% em pacientes chagásicos (8,33 ± 2,44% para 10,7 ± 1,98%) após aplicação da TENS ganglionar. A VFC apresentou um padrão de redução da atividade simpática durante a modulação autonômica. Conclusão: Apesar de não alterar os índices da VFC, a aplicação da TENS sobre a região cérvico-torácica melhorou o ajuste da função endotelial da artéria braquial. Este resultado ratifica o efeito vascular da TENS aplicada sobre o gânglio estrelado e demonstra a capacidade preservada de dilatação dos vasos na insuficiência cardíaca chagásica. / Background: Transcutaneous electrical nerve stimulation (TENS) over cervicothoracic region has been shown to increase peripheral blood flow through autonomic modulation in healthy individuals and vascular ischemia. Patients with heart failure with chagasic etiology show fibrosis of the myocardial fibers without severe vascular impairment, but with greater compensatory autonomic overload. Our hypothesis is that GEE may modulate sympathetic hyperactivity and vascular function in this population. Objectives - To evaluate the effect of ganglionic transcutaneous electrical nerve stimulation on heart rate variability (HRV) and flow - mediated dilatation (FMD) in patients with chagasic heart failure. Methods: It was a randomized controlled trial. Twenty men (10 healthy and 10 chagasic) underwent interventional stimulation (TENS or placebo) applied over the ganglionic region (C7 and T4 vertebrae) for 30 minutes. HRV and images of blood flow and vascular resistance were continuously monitored during the seven steps of the collection protocol while images of FMD were recorded before and after the intervention during the 5 minutes of cuff-occlusion release of brachial artery. The effects of the intervention were compared using the Two-Way ANOVA test with Tukey Post-hoc test for bothe groups considering a p <0.05. Results: Flow-mediated dilation (FMD) increased 69.93% in healthy subjects (6.32 ± 2.39% to 10.74 ± 2.52%) and 28.45% in chagasic patients (8.33 ± 2.44% to 10.7 ± 1.98%) after GEE application. Heart rate variability (HRV) showed a pattern of reduction of sympathetic activity during autonomic modulation. Conclusion: Despite we didn't find any change in HRV indexes, the application of TENS over cervico-thoracic region improved the endothelial function of the brachial artery. This result ratifies the vascular effect of TENS applied on the star ganglion and demonstrates the preserved capacity of vessel dilatation in chagasic heart failure. / Background: Transcutaneous electrical nerve stimulation (TENS) over cervicothoracic region has been shown to increase peripheral blood flow through autonomic modulation in healthy individuals and vascular ischemia. Patients with heart failure with chagasic etiology show fibrosis of the myocardial fibers without severe vascular impairment, but with greater compensatory autonomic overload. Our hypothesis is that GEE may modulate sympathetic hyperactivity and vascular function in this population. Objectives - To evaluate the effect of ganglionic transcutaneous electrical nerve stimulation on heart rate variability (HRV) and flow - mediated dilatation (FMD) in patients with chagasic heart failure. Methods: It was a randomized controlled trial. Twenty men (10 healthy and 10 chagasic) underwent interventional stimulation (TENS or placebo) applied over the ganglionic region (C7 and T4 vertebrae) for 30 minutes. HRV and images of blood flow and vascular resistance were continuously monitored during the seven steps of the collection protocol while images of FMD were recorded before and after the intervention during the 5 minutes of cuff-occlusion release of brachial artery. The effects of the intervention were compared using the Two-Way ANOVA test with Tukey Post-hoc test for bothe groups considering a p <0.05. Results: Flow-mediated dilation (FMD) increased 69.93% in healthy subjects (6.32 ± 2.39% to 10.74 ± 2.52%) and 28.45% in chagasic patients (8.33 ± 2.44% to 10.7 ± 1.98%) after GEE application. Heart rate variability (HRV) showed a pattern of reduction of sympathetic activity during autonomic modulation. Conclusion: Despite we didn't find any change in HRV indexes, the application of TENS over cervico-thoracic region improved the endothelial function of the brachial artery. This result ratifies the vascular effect of TENS applied on the star ganglion and demonstrates the preserved capacity of vessel dilatation in chagasic heart failure.

Page generated in 0.0858 seconds