• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 298
  • 195
  • 38
  • 21
  • 18
  • 11
  • 10
  • 10
  • 8
  • 6
  • 6
  • 5
  • 5
  • 2
  • 2
  • Tagged with
  • 702
  • 613
  • 377
  • 275
  • 202
  • 199
  • 126
  • 109
  • 90
  • 78
  • 75
  • 66
  • 65
  • 61
  • 56
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
501

Impacto da pericardiectomia sobre a fisiologia cardiorrespiratória de pacientes com pericardite constritiva crônica durante a vigília e sono / Impact of pericardiectomy on cardiorespiratory physiology of patients with chronic constrictive pericarditis during wakefulness and sleep

Melo, Dirceu Thiago Pessôa de 10 March 2017 (has links)
Introdução: A pericardiectomia é o tratamento de escolha para pacientes com pericardite constritiva crônica sintomática, entretanto, o impacto do procedimento na capacidade cardiopulmonar e fisiologia cardiorrespiratória durante a vigília e sono é pouco estudado. Objetivo: Avaliar o impacto da cirurgia de pericardiectomia sobre a capacidade funcional de pacientes com pericardite constritiva crônica sintomática. Métodos: Trata-se de estudo observacional prospectivo com 25 pacientes consecutivos com diagnóstico de pericardite constritiva crônica submetidos à pericardiectomia. Foram realizados os seguintes procedimentos uma semana antes e seis meses após a pericardiectomia: avaliação clínica e antropométrica, avaliação da qualidade de vida e do sono, dosagem dos níveis séricos de BNP, ecocardiograma transtorácico, teste cardiopulmonar de esforço, polissonografia noturna completa. Resultados: A idade média foi 45 anos, com predomínio do sexo masculino (76%). A etiologia foi principalmente idiopática (76%), seguida por tuberculose (12%). O ecocardiograma revelou fração de ejeção do ventrículo esquerdo preservada e dilatação de veia cava inferior (92%) na maioria dos pacientes. Todos os pacientes foram submetidos à pericardiectomia de frênico a frênico via esternotomia mediana, sem circulação extracorpórea. Após a pericardiectomia, houve redução da: classe funcional III/IV (56% vs. 8%, p < 0,001), ascite (72% vs. 12%, p < 0,001) e edema de membros inferiores (88% vs. 24%, p < 0,001) em relação ao pré-operatório. O teste cardiopulmonar revelou melhora do VO2 pico (18,7 ± 5,6 vs. 25,2 ± 6,3 mL/kg/min, p < 0,001), limiar anaeróbico (13,1 ± 3 vs. 17,7 ± 5,5 mL/kg/min, p < 0,001) e velocidade na esteira rolante de 2,5 (2-2,5) para 3 (2,5-3,3) mph, p=0,001. Na análise multivariada, a idade foi o único preditor independente da variação de VO2 (r=-0,658, p=0,003). Os níveis séricos de BNP apresentaram redução significativa de 143 (83,5-209,5) pg/mL para 76 (40-117,5) pg/mL, p=0,011. A polissonografia noturna completa no pré-operatório demonstrou a presença de apneia do sono moderada/ grave (IAH >= 15 eventos/hora) em 13 pacientes, com predomínio de hipopneias. Não houve mudança significativa do índice de apneia-hipopneia após a pericardiectomia: IAH pré 15,6 (8,3-31,7) vs. IAH pós 14,6 (5,75-29,9), p=0,253; entretanto, houve melhora da qualidade do sono (Pittsburgh pré 7,8 ± 4,10 vs. Pittsburgh pós 4,7 ± 3,7, p < 0,001). O IAH apresentou correlação positiva com os níveis de BNP (r=0,418, p=0,037) e EuroSCORE (r=0,480, p=0,015) no pré-operatório. Conclusão: Pacientes com pericardite constritiva crônica sintomática apresentaram, seis meses após a cirurgia de pericardiectomia, melhora da capacidade cardiopulmonar, da classe funcional e da qualidade de vida. A apneia do sono se mostrou frequente e apresentou correlação com níveis séricos de BNP e EuroSCORE no pré-operatório. O índice de apneia-hipopneia não apresentou mudanças significativas após a pericardiectomia. A despeito disso, houve melhora da qualidade do sono / Introduction: Pericardiectomy is the treatment of choice for patients with symptomatic chronic constrictive pericarditis; however, the impact of the procedure on cardiopulmonary capacity and cardiorespiratory physiology during wakefulness and sleep has been poorly studied so far. Objective: To evaluate the impact of pericardiectomy surgery on functional capacity of patients with symptomatic chronic constrictive pericarditis. Methods: This is a prospective observational study with 25 consecutive patients diagnosed with chronic constrictive pericarditis submitted to pericardiectomy. The following procedures were performed one week before and six months after pericardiectomy: clinical and anthropometric evaluation, quality of life and sleep evaluation, serum BNP levels, transthoracic echocardiography, cardiopulmonary exercise test, complete nocturnal polysomnography. Results: The mean age was 45, with a predominance of males (76%). The etiology was mainly idiopathic (76%), followed by tuberculosis (12%). The echocardiogram revealed preserved left ventricular ejection fraction and inferior vena cava dilatation (92%) in most patients. All patients underwent phrenic to phrenic pericardiectomy via median sternotomy, without extracorporeal circulation. After pericardiectomy there was a reduction in: functional class III / IV (56% vs. 8%, p < 0.001), ascites (72% vs. 12%, p < 0.001) and lower limb edema (88% vs. 24%, p < 0.001) as compared to the preoperative period. The cardiopulmonary test revealed improvement in VO2 peak (18.7 ± 5.6 vs. 25.2 ± 6.3 mL/kg/min, p < 0.001), anaerobic threshold (13.1 ± 3 vs. 17.7 ± 5.5 mL/kg/min, p < 0.001) and velocity on the treadmill from 2.5 (2-2.5) to 3 (2.5-3.3) mph, p=0.001. In multivariate analysis, age was the only independent predictor of VO2 variation (r = -0.658, p = 0.003). Serum BNP levels showed a significant reduction from 143 (83.5-209.5) pg/mL to 76 (40-117.5) pg/mL, p=0.011. The complete nocturnal polysomnography in the preoperative period showed moderate / severe sleep apnea (AHI >= 15 events / hour) in 13 patients, predominantly hypopnea. There was no significant change in apnea-hypopnea index after pericardiectomy: AHI pre 15.6 (8.3-31.7) vs. AHI post 14.6 (5.75-29.9), p= 0.253; however, there was improvement in sleep quality (Pittsburgh pre 7.8 ± 4.10 vs. Pittsburgh post 4.7 ± 3.7, p < 0.001). AHI presented a positive correlation with BNP levels (r=0.418, p=0.037) and EuroSCORE (r=0.480; p=0.015) in the preoperative period. Conclusion: Patients with symptomatic chronic constrictive pericarditis showed improvement in cardiopulmonary capacity, functional class and quality of life six months after pericardiectomy. Sleep apnea was frequent and correlated with serum levels of BNP and EuroSCORE in the preoperative period. The apnea-hypopnea index did not show significant changes after pericardiectomy. Nevertheless, there was an improvement in sleep quality
502

Resposta vascular durante o teste de estresse mental em adultos fisicamente ativos e sedentários com apneia obstrutiva do sono / Vascular response during the mental stress test in physically active and sedentary adults with obstructive sleep apnea

Silva, Rosyvaldo Ferreira 30 October 2017 (has links)
O objetivo deste estudo foi comparar a resposta do vascular durante o teste de estresse mental em adultos sedentários (SED) e fisicamente ativos (FA) com apneia obstrutiva do sono (AOS). Os pacientes não tratados com AOS e sem outras comorbidades foram classificados em SED e FA de acordo com o Questionário Internacional de atividade física. A pressão sanguínea, a freqüência cardíaca, o fluxo sanguíneo do antebraço (FSA) (pletismografia) e a condutância vascular do antebraço (CVA = FSA/pressão sanguínea x 100) foram medidas continuamente em repouso (4 min), seguidas de 3 min do teste Stroop Color Word Test (SCWT) também conhecido como teste de estresse mental. Quarenta pacientes com AOS (homens = 24, idade = 50 ± 1 anos, índice de massa corporal = 29 ± 0,5 Kg/m2, índice de apneia hipopnéia = 39 ± 4 eventos/h) divididos em SED (n = 21) e FA (n = 19) apresentaram diferença significativa na quantidade de tempo gasto em atividade física (17 ± 9 vs. 245 ± 33 minutos/semana, respectivamente). Os grupos foram semelhantes em relação ao sexo, idade, índice de massa corporal, frequência cardíaca do nível educacional e pressão arterial média em repouso, bem como percepção de estresse no final do SCWT. Em contraste, FSA basal (1,7 ± 0,08 mL/min/100mL vs 2,5 ± 0,19 mL/min/100mL) e CVA (1,7 ± 0,07 vs 2,5 ± 0,2) foram significativamente menores no grupo SED quando comaprados a FA, respectivamente (p <0,05). A resposta de frequência cardíaca e pressão arterial ao SCWT foram semelhantes e aumentou em ambos os grupos. O FSA (3,5 ± 0,2 mL/min/100mL vs 2,4 ± 0,14 mL/min/100mL) e a CVA (3,5 ± 0,2 vs 2,3 ± 0,1) durante SCWT foi significativamente menor no grupo SED quando comparados ao grupo FA (P <0,05). Houve uma correlação significativa entre a atividade física no tempo de lazer e FSA (r = 0,57; P <0,05) e CVA (r = 0,48; P <0,05). Conclui-se, que, a resposta vascular nos pacientes com AOS é influenciada pelo nível de atividade física de lazer. O alto nível de atividade física pode proteger a disfunção cardiovascular em repouso e na condição de estresse mental em pacientes com AOS moderado a severo / The objective of this study was to compare a vascular response during the mental stress test in sedentary (SED) and physically active (PA) patients with obstructive sleep apnea (OSA). Patients not treated with OSA and without other comorbidities were classified in SED and PA according to the International Questionnaire of Physical Action. Blood pressure, heart rate, forearm blood flow (plethysmography) and forearm vascular conductance (FVC = FBF / blood pressure x 100) were measured continuously at rest (4 min), followed by 3 min of the test Stroop Color Word Test (SCWT) also known as mental stress test. Forty patients with OSA (men = 24, age = 50 ± 1 years, body mass index = 29 ± 0.5 kg / m2, apnea hypopnea index = 39 ± 4 events / h) divided in SED (n = 19) and PA (n = 19) presented a significant difference in the amount of time spent in physical activity (17 ± 9 vs. 245 ± 33 minutes / week, respectively). The groups are similar in relation to gender, age, body mass index, heart rate at educational level, and mean resting blood pressure, as well as perceived stress at the end of SCWT. In contrast, baseline FBF (1.7 ± 0.08 mL/min/100mL vs 2.5 ± 0.19 mL/min/100mL) and FVC (1.7 ± 0.07 U vs 2.5 ± 0.2 U) were significantly lower without SED group when compared to PA, respectively (p <0.05). The heart rate and blood pressure response to SCWT were similar and increased in both groups. The FBF (3.5 ± 0.2 mL/min/100mL vs 2.4 ± 0.14 mL/min/100mL) and the FVC (3.5 ± 0.2 U vs 2.3 ± 0.1 U) during SCWT was much lower in the SED group when compared to the group PA (P <0.05). There was a significant correlation between physical activity without leisure time and FBF (r = 0.57, P <0.05) and FVC (r = 0.48, P <0.05). In conclusion, the vascular response in OSA patients is influenced by the level of leisure physical activity. The high level of physical activity may protect a cardiovascular dysfunction at rest and mental stress condition in patients with moderate to severe OSA
503

Avaliação das alterações nas vias aéreas superiores através de tomografia computadorizada Cone-Beam em pacientes submetidos à cirurgia ortognática de avanço bimaxilar / Three-dimensional upper airway space changes after bimaxillary advancement by Cone-Beam Computed Tomography

Rocha, Thais Lima 11 May 2016 (has links)
Introdução: O descontentamento com a estética facial é considerado o fator motivador mais frequente na procura pela cirurgia ortognática, visto que este é o procedimento indicado nos casos de severas discrepâncias dentoesqueléticas em pacientes adultos. A anatomia das vias aéreas superiores (VAS) permite que fatores como obesidade, hipotonia muscular e deficiência mandibular favoreçam sua obstrução, podendo gerar a Apneia Obstrutiva do Sono (AOS), caracterizada por episódios recorrentes de obstrução parcial ou completa das VAS durante o sono. As cirurgias de avanço bimaxilar estão associadas ao aumento do espaço aéreo, no entanto, as alterações morfológicas e volumétricas ainda não são bem conhecidas. Objetivos: Avaliar as alterações em 3D do espaço aéreo faríngeo frente aos procedimentos de cirurgia ortognática de avanço bimaxilar em pacientes Classe I e II esqueléticos. Material e Métodos: A análise da área axial mínima e do volume da aérea superior foi realizada em pré-operatório (T0) e pós-operatório (T1) de 56 pacientes, sendo 21 do sexo masculino e 35 do sexo feminino, com média de idade de 35,8 (±10,7) anos, submetidos ao avanço bimaxilar pela técnica da osteotomia sagital de mandíbula bilateral associada ao avanço de maxila por meio de osteotomia Le Fort I. As avaliações foram feitas através de tomografia computadorizada Cone-beam, utilizando-se o Programa Dolphin Imaging 11.7. Foi utilizado o teste t pareado para comparar os dados pré e pós-operatórios. Todos os testes foram realizados com o programa Statistica, adotando-se um nível de significância de 5%. Resultados: No estudo do erro do método, não houve erro casual nem sistemático entre a primeira e a segunda medição das variáveis (p >0,05 em todas as medidas). A cirurgia de avanço bimaxilar apresentou uma média de 73,6% (± 74,75%) de aumento volumétrico e 113,5% (±123,87%) de aumento na área axial mínima. Conclusões: Podemos concluir que a cirurgia de avanço bimaxilar proporciona um aumento volumétrico significativo no espaço aéreo superior, bem como na área axial mínima, no entanto, esse ganho nem sempre ocorre na mesma magnitude para todos os pacientes. / Introduction: Facial aesthetics dissatisfaction is considered the most common motivating factor in the search for orthognathic surgery. This procedure may be used in cases of severe dental and skeletal discrepancies in adult patients. The restricted space anatomy of the upper airway space (UAS) allows features such as obesity, muscular hypotonia and mandibular deficiency favor clogging, which may lead to obstructive sleep apnea (OSA), characterized by recurrent episodes of partial or complete obstruction of the UAS during sleep. Surgeries of bimaxillary advancement are associated with increased UAS, however, the morphological and volumetric changes are not well known. Objectives: to evaluate changes in 3D pharyngeal airway in front of orthognathic surgery procedures of skeletal Class I and II subjects. Material and Methods: 3D pharyngeal airway was evaluated preoperative (T0) and postoperative (T1), with the aid of the analysis of the minimum axial area and airway volume. Fifty-six patients 21 male and 35 female, with a mean age of 35.8 (± 10.7) years undergo bimaxillary advancement by the technique of bilateral sagittal split osteotomy of the mandible associated with maxillary advancement through Le Fort I osteotomy. Measurements were made using Cone-beam Computed Tomography, using the Dolphin Imaging program 11.7. Paired t test was used to compare to the data between T0 and T1. All tests were performed with the Statistica Program, adopting a 5% significance level. Results: In the method error of the study, there was no casual or systematic error between the first and second measurement variables (p > 0.05 for all measures). The bimaxillary advancement surgery showed an average of 73.6% (± 74.75%) of increase in volume and 113.5% (±123.87%) increase in the minimum axial area. Conclusions: We concluded that the maxillomandibular advancement surgery provides a significant increase in volume in the UAS as well as the minimum axial area; however, this gain is not always in the same magnitude for all patients.
504

Prävalenz schlafbezogener Atmungsstörungen bei Herzschrittmacherpatienten

Riedel, Frank 03 July 1998 (has links)
Ziel der Untersuchung war die Ermittlung der Prävalenz schlafbezogener Atmungsstörungen (SBAS) in einer Gruppe von Herzschrittmacherpatienten. Durch Gegenüberstellung mit der in der Literatur angegebenen Prävalenz SBAS in vergleichbaren Patientengruppen ohne Herzschrittmacher sollte eine Aussage über einen möglichen Zusammenhang zwischen SBAS und schrittmacherbedürftigen Herzrhythmusstörungen getroffen werden. Dieser Zusammenhang könnte indirekt über die bekannte Koinzidenz zwischen SBAS und arterieller Hypertonie bzw. KHK bestehen. Es wurden 192 Patienten (100 Männer, 92 Frauen) der Rhythmussprechstunde des Universitätsklinikums Charité in Berlin mit einem Durchschnittsalter von 62,2 +/- 12,2 Jahren ambulant für eine Nacht untersucht. Zum Einsatz kam das tragbare Schlafapnoe-Monitoring-Gerät MESAM IV. Schlafbezogene Atmungsstörungen lagen dann vor, wenn der respiratorische Gesamtindex (RDI = respiratory disturbance index) als Summe der Apnoen und Hypopnoen pro Stunde Schlaf größer oder gleich 10 war. Anhand des RDI erfolgte eine Einteilung der Patienten in Diagnosegruppen: Gruppe A (RDI < 5, kein Vorliegen SBAS), Gruppe B (RDI >= 5 und < 10, Grenzbefund) und Gruppe C (RDI >= 10, Vorliegen SBAS). Ergebnisse (Gesamtkollektiv / Männer / Frauen): Gruppe A: 100 / 44 / 56 Patienten (52,1 / 44,0 / 60,9 %) Gruppe B: 30 / 16 / 14 Patienten (15,6 / 16,0 / 15,2 %) Gruppe C: 62 / 40 / 22 Patienten (32,3 / 40,0 / 23,9 %). Signifikant häufiger wurden SBAS (Gruppe C) bei Männern als bei Frauen nachgewiesen. Ebenso liegen das Durchschnittsalter (Gruppe A: 58,5 +/- 14,5 Jahre, Gruppe C 67,3 +/- 6,8 Jahre) sowie der durchschnittliche Body-Mass-Index (Gruppe A: 24,8 +/- 3,4 kg/m2, Gruppe C 27,1 +/- 3,3 kg/m2) bei Patienten mit SBAS signifikant höher als bei Patienten ohne SBAS. Patienten mit unterschiedlichen, der Schrittmacherimplantation zugrundeliegenden, Herzerkrankungen (z. B. Sick-Sinus-Syndrom, AV-Block, Bradyarrhythmia absoluta) wiesen keine signifikanten Differenzen in der Häufigkeit SBAS auf. Gleichermaßen konnte das Vorliegen zusätzlicher kardiovaskulärer Erkrankungen und Risikofaktoren (z. B. KHK, arterielle Hypertonie, Rauchen) nicht als Einflußfaktor für das gehäufte Auftreten SBAS nachgewiesen werden. Angaben zur Prävalenz SBAS in der Literatur schwanken für die entsprechende Altersgruppe von Patienten ohne Herzschrittmacher zwischen 24 % und 73 %. Die für die Herzschrittmacherpatienten ermittelte Prävalenz der SBAS mit 32,3 % liegt innerhalb dieser großen Spannbreite. Die Untersuchungsergebnisse ergaben daher keinen Zusammenhang zwischen SBAS und schrittmacherbedürftigen Herzrhythmusstörungen. Auch konnte kein Unterschied im Auftreten SBAS in Abhängigkeit von der Art der Herzrhythmusstörung nachgewiesen werden. Weiterführende Untersuchungen (z. B. in Form einer Fall-Kontroll-Studie) erscheinen notwendig. / The study was aimed to determine prevalence of sleep-related respiratory disturbances (SRRD) in a group of pacemaker patients. It was investigated if SRRD are more prevalent in pacemaker patients compared to corresponding patients without pacemaker. This question was raised in background of the wellknown coincidence of SRRD and arterial hypertension respectively coronary heart disease. References about the prevalence of SRRD in corresponding elderly people served as standard of comparison. 192 hospital outpatients (100 men and 92 women) from rhythmological ambulance of university hospital "Charité" in Berlin were randomly selected and examined for one night by means of MESAM IV device, a Non-laboratory-monitoring-system". The mean age of these patients was 62,2 +/- 12,2 years. A respiratory disturbance index (RDI; the sum of apneas and hypopneas per hour of sleep) equal or greater than 10 was laid down for the existence of SRRD. The RDI built the basis for dividing the patients into three groups: Group A (RDI < 5, no SRRD), Group B (RDI >= 5 and < 10, borderline SRRD) an Group C (RDI >= 10, SRRD). Results (all patients / men / women): Group A: 100 / 44 / 56 patients (52,1 / 44,0 / 60,9 %) Group B: 30 / 16 / 14 patients (15,6 / 16,0 / 15,2 %) Group C: 62 / 40 / 22 patients (32,3 / 40,0 / 23,9 %). Significant differences occured in the frequency of SRRD (Group C) between men and women. Apart from that the mean age (Group A: 58,5 +/- 14,5 years, Group C: 67,3 +/- 6,8 years) as well as the Body-Mass-Index (Group A: 24,8 +/- 3,4 kg/m2, Group C: 27,1 +/. 3,3 kg/m2) were significantly higher in patients with SRRD than in patients without SRRD. No significant differences in the frequency of SRRD could be demonstrated in dependence on underlying rhythm disturbances (e. g. Sick-Sinus-Syndrom, atrioventricular block, Bradyarrhythmia absoluta). In the same manner no evidences regarding significant influences of additionally existing cardiovascular diseases or risk factors (e. g. coronary heart disease, arterial hypertension, smoking) on the appearance of SRRD were shown. References about the prevalence of SRRD in corresponding elderly people without pacemaker vary from 24 % to 73 %. The prevalence of SRRD in pacemaker patients (32,3 %) fits right in the frame of this great variety. A more frequent appearance of SRRD in patients with pacemaker than in patients without could not be proved. Equally, the underlying rhythm disturbance has apparently no correlation to SRRD. Extended studies are necessary.
505

Avaliação da eficácia da máscara oronasal vs nasal com uso de pressão positiva para o tratamento da apneia obstrutiva do sono / Evaluation of the effectiveness of oronasal vs nasal mask with use of positive pressure for the obstructive sleep apnea treatment

Weaver, Fernanda Madeiro Leite Viana 22 March 2019 (has links)
Introdução: A aplicação de Pressão Positiva Contínua na Via Aérea Superior (CPAP) durante o sono é o tratamento padrão ouro para Apneia Obstrutiva do Sono (AOS) e foi primeiramente descrita utilizando uma máscara nasal. No entanto, na prática clínica a máscara oronasal é comumente utilizada e sua eficácia é variável devido a mecanismos desconhecidos. Nós formulamos a hipótese de que a respiração oral e a transmissão de pressão pela cavidade oral comprometem a eficácia do CPAP com máscara oronasal. Métodos: Treze pacientes com AOS, bem adaptados à máscara oronasal, foram monitorados com polissonografia completa, cateter de pressão faríngea e nasoendoscopia. Os pacientes dormiram com uma máscara oronasal com compartimentos nasal e oral separados e selados entre si. Cada compartimento nasal e oral foi conectado a um pneumotacógrafo e ambos foram conectados a uma válvula multidirecional a fim de ser possível modificar o fluxo de CPAP (nasal ou oronasal), sem a necessidade de acordar o paciente. Um cateter de pressão faríngea e broncoscópio pediátrico ultra-fino foram introduzidos por orifícios independentes através da máscara. O sono foi induzido com baixas doses de midazolam. O CPAP foi titulado até a pressão terapêutica durante as rotas oronasal e nasal. O CPAP foi então reduzido para induzir limitação de fluxo aéreo estável na rota oronasal e abruptamente mudado para a rota nasal e vice-versa. Adicionalmente, o experimento foi repetido com o uso de uma fita selando a boca do paciente a fim de bloquear a transmissão de pressão pela cavidade oral. Resultados: A pressão de titulação de CPAP foi maior na rota oronasal quando comparada à nasal (p=0,005). Cinco de 11 pacientes, com uma alta porcentagem de respiração oral ( > 25%), não obtiveram sucesso na titulação do CPAP com máscara oronasal. Durante limitação de fluxo aéreo estável o pico de fluxo inspiratório foi menor, o delta de pressão faríngea e a resistência inspiratória da via aérea superior foram maiores, enquanto as dimensões nas regiões retropalatal e retroglossal foram menores na rota oronasal comparada à nasal (p < 0,05 para todas as comparações). As diferenças foram observadas mesmo em pacientes sem respiração oral e foram abolidas quando selamos a boca do paciente com uma fita (n=6). Conclusão: Respiração oral e transmissão de pressão positiva pela cavidade oral comprometem a eficácia do CPAP com máscara oronasal / BACKGROUND: Continuous Positive Airway Pressure (CPAP) is the gold standard treatment for obstructive sleep apnea (OSA) and was conceived to be applied by nasal route only. Oronasal mask is frequently used in clinical practice but the effectiveness varies for unknown mechanisms. We hypothesized that oral breathing and pressure transmission through the mouth compromises oronasal CPAP efficacy. METHODS: Thirteen OSA patients, well adapted to oronasal CPAP, were monitored by full polysomnography, pharyngeal pressure catheter and nasoendoscopy. Patients slept with an oronasal mask with sealed nasal and oral compartments. Sleep was induced with low doses of midazolam. CPAP was titrated during both oronasal and nasal routes. CPAP was then reduced to induce stable airflow limitation and abruptly switched to the alternate route. In addition, a tape sealing the mouth was used to block pressure transmission to the oral cavity. RESULTS: Best titrated CPAP was higher in oronasal than nasal route (p=0.005). Five out of 11 patients with a high percentage of oral breathing ( > 25%) failed to achieve stable breathing during oronasal CPAP titration. During stable flow limitation, inspiratory peak flow was lower, driving pressure and upper airway inspiratory resistance were higher, retropalatal and retroglossal dimensions were smaller in oronasal compared to nasal route (p < 0.05 for all comparisons). Differences were observed even among patients with no oral flow and were abolished when a tape sealing the mouth was used (n=6). CONCLUSION: Oral breathing and transmission of positive pressure through the mouth compromises oronasal CPAP
506

Avaliação das alterações nas vias aéreas superiores através de tomografia computadorizada Cone-Beam em pacientes submetidos à cirurgia ortognática de avanço bimaxilar / Three-dimensional upper airway space changes after bimaxillary advancement by Cone-Beam Computed Tomography

Thais Lima Rocha 11 May 2016 (has links)
Introdução: O descontentamento com a estética facial é considerado o fator motivador mais frequente na procura pela cirurgia ortognática, visto que este é o procedimento indicado nos casos de severas discrepâncias dentoesqueléticas em pacientes adultos. A anatomia das vias aéreas superiores (VAS) permite que fatores como obesidade, hipotonia muscular e deficiência mandibular favoreçam sua obstrução, podendo gerar a Apneia Obstrutiva do Sono (AOS), caracterizada por episódios recorrentes de obstrução parcial ou completa das VAS durante o sono. As cirurgias de avanço bimaxilar estão associadas ao aumento do espaço aéreo, no entanto, as alterações morfológicas e volumétricas ainda não são bem conhecidas. Objetivos: Avaliar as alterações em 3D do espaço aéreo faríngeo frente aos procedimentos de cirurgia ortognática de avanço bimaxilar em pacientes Classe I e II esqueléticos. Material e Métodos: A análise da área axial mínima e do volume da aérea superior foi realizada em pré-operatório (T0) e pós-operatório (T1) de 56 pacientes, sendo 21 do sexo masculino e 35 do sexo feminino, com média de idade de 35,8 (±10,7) anos, submetidos ao avanço bimaxilar pela técnica da osteotomia sagital de mandíbula bilateral associada ao avanço de maxila por meio de osteotomia Le Fort I. As avaliações foram feitas através de tomografia computadorizada Cone-beam, utilizando-se o Programa Dolphin Imaging 11.7. Foi utilizado o teste t pareado para comparar os dados pré e pós-operatórios. Todos os testes foram realizados com o programa Statistica, adotando-se um nível de significância de 5%. Resultados: No estudo do erro do método, não houve erro casual nem sistemático entre a primeira e a segunda medição das variáveis (p >0,05 em todas as medidas). A cirurgia de avanço bimaxilar apresentou uma média de 73,6% (± 74,75%) de aumento volumétrico e 113,5% (±123,87%) de aumento na área axial mínima. Conclusões: Podemos concluir que a cirurgia de avanço bimaxilar proporciona um aumento volumétrico significativo no espaço aéreo superior, bem como na área axial mínima, no entanto, esse ganho nem sempre ocorre na mesma magnitude para todos os pacientes. / Introduction: Facial aesthetics dissatisfaction is considered the most common motivating factor in the search for orthognathic surgery. This procedure may be used in cases of severe dental and skeletal discrepancies in adult patients. The restricted space anatomy of the upper airway space (UAS) allows features such as obesity, muscular hypotonia and mandibular deficiency favor clogging, which may lead to obstructive sleep apnea (OSA), characterized by recurrent episodes of partial or complete obstruction of the UAS during sleep. Surgeries of bimaxillary advancement are associated with increased UAS, however, the morphological and volumetric changes are not well known. Objectives: to evaluate changes in 3D pharyngeal airway in front of orthognathic surgery procedures of skeletal Class I and II subjects. Material and Methods: 3D pharyngeal airway was evaluated preoperative (T0) and postoperative (T1), with the aid of the analysis of the minimum axial area and airway volume. Fifty-six patients 21 male and 35 female, with a mean age of 35.8 (± 10.7) years undergo bimaxillary advancement by the technique of bilateral sagittal split osteotomy of the mandible associated with maxillary advancement through Le Fort I osteotomy. Measurements were made using Cone-beam Computed Tomography, using the Dolphin Imaging program 11.7. Paired t test was used to compare to the data between T0 and T1. All tests were performed with the Statistica Program, adopting a 5% significance level. Results: In the method error of the study, there was no casual or systematic error between the first and second measurement variables (p > 0.05 for all measures). The bimaxillary advancement surgery showed an average of 73.6% (± 74.75%) of increase in volume and 113.5% (±123.87%) increase in the minimum axial area. Conclusions: We concluded that the maxillomandibular advancement surgery provides a significant increase in volume in the UAS as well as the minimum axial area; however, this gain is not always in the same magnitude for all patients.
507

Fysisk kapacitet hos personer med obstruktiv sömnapné, övervikt och låg fysisk aktivitetsnivå : - En jämförande &amp; sambandstudie

Bjernulf, Alfred, Oscar, Kolbe January 2019 (has links)
Bakgrund Obstruktiv sömnapné (OSA) karakteriseras av upprepade episoder av helt eller delvis avstängda luftvägar under sömn. Det saknas studier som undersöker samband mellan fysisk kapacitet och graden av OSA, Body Mass Index (BMI), dagtrötthet, mängden tid med lågintensiv fysisk aktivitet (LFA) och ålder hos personer med OSA.   Syfte Syftet var att se hur fysisk kapacitet skiljer sig hos personer med OSA beroende på graden av OSA, BMI, dagtrötthet, mängden LFA och ålder samt studera sambandet mellan dessa variabler.   Metod Studien var en tvärsnittsstudie med en jämförande och korrelerande design. Data kommer från baslinjemätningar av en randomiserad kontrollerad studie på 86 deltagare med diagnosen OSA (AHI &gt;15), BMI &gt;25, samt en självskattad måttligt intensiv fysisk aktivitet på mindre än 150 minuter/vecka. Dagtrötthet mättes med Epworth sleepiness scale och LFA mättes med accelerometer.    Resultat Det fanns ett signifikant samband mellan prestation på 6 MWT och ålder respektive mängden tid i LFA. Hög ålder och få minuter av LFA korrelerar med kortare gångsträcka. Personer med övervikt hade längre gångsträcka än personer med fetma. Det var inga skillnader i gångsträcka beroende på graden av OSA eller om det förekom dagtrötthet.   Slutsats Ålder och BMI bör tas i beaktande vid utförandet och utvärdering av gångtest för personer med OSA. Personer med OSA som utför mer LFA hade en högre kapacitet vilket möjligen kan förklaras av att de är mindre stillasittande. Mer forskning behövs på ämnet för att ta reda på bakomliggande orsaker och se kausala samband.
508

Controle quimiorreflexo da atividade nervosa simpática e do fluxo sanguíneo muscular em pacientes com insuficiência cardíaca e distúrbio respiratório do sono / Chemoreflex control of muscle sympathetic nerve activity and muscle blood flow in patients with heart failure and sleep disordered breathing

Lobo, Denise Moreira Lima 30 November 2016 (has links)
Introdução: Os distúrbios respiratórios do sono são comuns em pacientes com insuficiência cardíaca. Estudos recentes mostram que pacientes com insuficiência cardíaca apresentam resposta vasoconstritora muscular paradoxal durante a estimulação dos quimiorreceptores centrais e periféricos e que essa resposta está associada à disfunção endotelial e à exacerbação nervosa simpática. Porém, o que não se conhece é se essa resposta está intensificada em pacientes com a coexistência de insuficiência cardíaca e distúrbio respiratório do sono. Objetivos: Testar a hipótese de que: 1) A resposta de fluxo sanguíneo muscular (FSM) durante a hipercapnia e a hipóxia seria menor em pacientes com insuficiência cardíaca e distúrbio respiratório do sono que em pacientes com insuficiência cardíaca sem distúrbio respiratório do sono; e 2) A resposta vasoconstritora mais exacerbada em pacientes com a coexistência de insuficiência cardíaca e distúrbio respiratório do sono estaria associada à disfunção endotelial e/ou à resposta exagerada da atividade nervosa simpática muscular (ANSM). Métodos: Foram avaliados, consecutivamente, 90 pacientes com insuficiência cardíaca, classe funcional II-III (New York Heart Association). Destes, 41 preencheram os critérios de inclusão e, após o exame de polissonografia, foram alocados em dois grupos, de acordo com o índice de apneia e hipopneia (IAH): Grupo IC (IAH < 15 eventos/hora; n=13; 46 (39-53) anos) e Grupo IC+DRS (IAH >= 15 eventos/hora; n=28; 57 (54-61) anos). O consumo de oxigênio no pico do exercício ( 2 pico) e a fração de ejeção do ventrículo esquerdo (FEVE) foram avaliados pelo teste cardiopulmonar em esforço e pela ecocardiografia transtorácica basal, respectivamente. Os FSM do antebraço e da panturrilha (FSMab e FSMp, respectivamente) foram avaliados pela pletismografia de oclusão venosa e a ANSM pela técnica de microneurografia. A pressão arterial média (PAM) e a frequência cardíaca (FC) foram avaliadas batimento a batimento de forma não invasiva (Finometer® PRO). O quimiorreflexo central foi estimulado por meio da inalação de uma mistura gasosa hipercápnica (7% CO2 e 93% O2) e o quimiorreflexo periférico por meio da inalação de uma mistura gasosa hipóxica (10% O2 e 90% N2), com isocapnia mantida, durante 3 minutos. Resultados: Os grupos foram semelhantes em relação à etiologia da insuficiência cardíaca 2 pico, índice de massa corpórea e medicações. No basal, não houve diferença entre os grupos quanto ao FSMab e FSMp, condutância vascular do antebraço (CVab) e panturrilha (CVp). Entretanto, a ANSM foi maior no grupo IC+DRS (P<0,05). Durante a hipercapnia, as respostas vasculares (FSMab, CVab, FSMp, CVp) foram significativamente menores no grupo IC+DRS quando comparadas com o grupo IC (P<0,001, para todas as comparações). De forma semelhante, durante a hipóxia, as respostas vasculares (FSMab, CVab, FSMp, CVp) foram significativamente menores no grupo IC+DRS quando comparadas com o grupo IC (P<=0,001, para todas as comparações). A ANSM, em resposta à hipercapnia e à hipóxia, foi maior no grupo IC+DRS. Durante a hipercapnia, as respostas de FC e PAM não foram diferentes entre os grupos. Durante a hipóxia, as respostas de FC não foram diferentes entre os grupos, enquanto a resposta de PAM foi maior nos pacientes do grupo IC+DRS. Não houve diferença na resposta ventilatória entre os grupos estudados. Conclusão: Pacientes com a coexistência de insuficiência cardíaca e distúrbio respiratório do sono apresentam vasoconstrição muscular paradoxal mais exacerbada que pacientes sem o distúrbio respiratório do sono, durante a hipercapnia e a hipóxia, o que parece estar associada, pelo menos em parte, à maior resposta de ANSM / Background: Sleep disordered breathing is common in heart failure patients. Recent studies show that patients with heart failure have paradox muscle vasoconstriction during the central and peripheral chemoreceptors stimulation, which is associated with endothelial dysfunction and exaggerated sympathetic nerve activity. However, whether this vascular response is more pronounced in patients with the coexistence of heart failure and sleep disordered breathing is unknown. Objectives: To test the hypothesis that: 1) The muscle vasoconstriction responses to hypercapnia and hypoxia would be more pronounced in heart failure patients with sleep disordered breathing than in heart failure patients without sleep disordered breathing; 2) This alteration in vascular responses would be associated with endothelial dysfunction and/or exaggerated muscle sympathetic nerve activity (MSNA) responses. Methods: Ninety consecutive heart failure patients, functional class II-III (New York Heart Association), were screened for the study. Forty-one patients who fulfilled all the inclusion criteria were enrolled and allocated into two groups according to apnea-hypopnea index (AHI): HF (AIH < v15 events/hour; n=13, 46 (39-53) years) and HF+SDB (AIH >=15 events/hour; n=28, 57 (54-61) years). Peak oxygen uptake (Peak 2) and left ventricular ejection fraction (LVEF) were evaluated by maximal incremental exercise test and by echocardiography, respectively. Forearm and calf blood flow (FBF and CBF, respectively) were evaluated by venous occlusion plethysmography and MSNA by microneurography technique. Mean blood pressure (MBP) and heart rate (HR) were evaluated by beat-to-beat noninvasive technique (Finometer® PRO). Central chemoreceptors were stimulated by inhalation of a hipercapnic gas mixture (7% CO2 and 93% O2) and peripheral chemoreceptors by inhalation of a hypoxic gas mixture (10% O2 and 90% N2), with maintenance of isocapnia, for 3 minutes each one. Results: Both groups were similar regarding to heart failure etiology, LVEF, Peak 2, body mass index, and medications. At baseline, there were no differences in FBF and CBF, forearm and calf vascular conductance (FVC and CVC, respectively) between groups. However, the MSNA was greater in HF+SDB group (P < 0.05). During hipercapnia, the vascular responses (FBF, FVC, CBF, CVC) were lower in HF+SDB group when compared to HF group (P < 0.001, to all comparisions). Similarly, during hypoxia, the vascular responses (FBF, FVC, CBF, CVC) were lower in HF+SDB group when compared to HF group (P <= 0.001, to all comparisions). The MSNA in response to hypercapnia and hypoxia was greater in HF+SDB group. During hypercapnia, the HR and MBP responses were not different between groups. During hypoxia, the HR responses were similar between groups, while the MBP responses were greater in HF+SDB group. There was no difference in ventilatory response between groups. Conclusion: Patients with the coexistence of heart failure and sleep disordered breathing have more intense muscle vasoconstriction than patients without sleep disordered breathing, during hypercapnia and hypoxia, which seems to be due, at least in part, to increased responsiveness of MSNA
509

Potenciais evocados auditivos de longa latência em indivíduos com apneia obstrutiva do sono / Long latency auditory evoked potentials in individuals with obstructive sleep apnea

Pedreno, Raquel Meirelles 18 May 2017 (has links)
Introdução: A Apneia Obstrutiva do Sono (AOS) é uma das entidades clínicas mais encontradas na população, sendo caracterizada por obstruções parcial ou total recorrente da via aérea durante o sono, levando a hipóxia intermitente e fragmentação do sono. Suas consequências envolvem sonolência excessiva, risco de acidentes de trabalho e de trânsito, déficits cognitivos e doenças cardiovasculares. Os potenciais evocados auditivos avaliam a atividade neuroelétrica na via auditiva, fornecendo uma medida objetiva do funcionamento do sistema auditivo. Visto que as alterações cognitivas na AOS podem ser múltiplas, espera-se que os potenciais evocados auditivos de longa latência (PEALL) possam ser utilizados como uma ferramenta de avaliação nos pacientes com AOS, mostrando uma melhor compreensão dos prejuízos da AOS e auxiliando no tratamento. Objetivo: Caracterizar os potenciais evocados auditivos de longa latência em indivíduos portadores de AOS de grau leve, moderado e grave, correlacionando os achados eletrofisiológicos com a severidade do distúrbio do sono, além de comparar com os resultados obtidos em indivíduos sem AOS. Método: Participaram deste estudo 59 indivíduos, na faixa etária de 22 a 54 anos (média de 34,87 anos) e de ambos os gêneros (52 homens e 07 mulheres). Os voluntários foram divididos em quatro grupos: sem AOS, com AOS leve, com AOS moderada e com AOS grave. Todos os participantes realizaram a polissonografia (PSG) para fornecer o grau da severidade da AOS, mesmo os voluntários sem queixa para AOS, para se descartar a possibilidade de apresentar a doença. Os indivíduos também foram submetidos à avaliação audiológica convencional. Para a obtenção dos componentes P1, N1, P2, N2 e P3 do PEALL, foram utilizados dois estímulos acústicos: fala (sílabas /ba/ e /da/), e tone-burst (frequências de 1000 Hz e 2000Hz), ambos na intensidade de 75dBnNA. Foram analisadas as latências (em ms) dos componentes P1, N1, P2, N2 e P3 e as amplitudes (em uv) P1- N1, P2-N2 e P3. Resultados: No PEALL com estímulo fala, o grupo grave apresentou a menor latência no N2 (p-valor < 0,001) e para o P3, todos os grupos apresentaram maior latência na orelha direita (p-valor=0,016). Houve diferença estatisticamente significante para amplitude do P3 (p-valor=0,016), com maior amplitude para orelha esquerda em todos os grupos. No PEALL com estímulo tone burst, apenas as latências dos componentes P2 e N2 apresentaram diferença estatisticamente significante (p-valor=0,010 e p-valor= 0,010, respectivamente), com menor latência para o grupo com AOS grave. Nestes mesmos componentes, houve diferença entre as orelhas. Foi encontrada diferença na amplitude P2-N2, com menor amplitude para o grupo com AOS grave (p-valor < 0,001). Conclusão: Indivíduos com AOS apresentam um aumento progressivo da latência do componente P3 dos PEALL conforme aumento da severidade da doença para o estímulo fala, bem como uma diminuição da amplitude P2-N2 para estímulo tone-burst no grupo com AOS grave quando comparada com os demais grupos, sugerindo interferência do grau de severidade da doença nos PEALL. De uma maneira geral, indivíduos com AOS grave apresentaram latências prolongadas e amplitudes reduzidas no PEALL quando comparados com indivíduos sem AOS / Introduction: The Obstructive Sleep Apnea (OSA) is one of the most common disease found in the population, characterized by partial or full airways obstruction during the sleep, leading to hypoxia and frequent awakenings. Its consequences are daytime sleepless, risk of work and car accidents, cognitive deficit and cardiovascular disease. The auditory evoked potential evaluates the neuroelectric activity in the auditory pathway, giving an objective measure about the auditory system function. Since the OSA cognitive dysfunctions can be multiples, it is expected that the Long Latency Auditory Evoked Potential (LLAEP) could be used as an evaluation tool in the patients with OSA, showing a better comprehension of its injuries and helping on the treatment. Objective: To characterize the long latency auditory evoked potentials in individuals with mild, moderate and severe OSA, comparing the results with the severity of the disease, and also comparing the results with individuals without OSA. Method: 59 individuals participated of this research, with ages bettwen 22 and 54 years old (average 34.87) and from both genders (52 men and 7 women). The volunteers were divided in four groups: without OSA, with mild OSA, moderate OSA and with severe OSA. All participants performed the polysomnography (PSG) for classifying the OSA severity, even the volunteers without OSA, to guarantee the inexistence of the disease. They were also submitted to a conventional audiology evaluation. To obtain the components P1, N1, P2, N2 and P3 in LLEAP, it was used two acoustic stimulus: speech (syllables / ba / e / da /), and tone-burst (frequencies of 1000 Hz and 2000 Hz), both with 75 dBnNA intensity. It were analyzed the latencies (in ms) of the components P1, N1, P2, N2 and P3 and the amplitudes (in uv) P1-N1, P2-N2 and P3 .Results: In the LLEAP with speech stimulus, the severe group presented the lowest latency in N2 (p-value < 0.001) and for P3, all groups had delay of latency in the right ear (p-value = 0.016). There was a significantly difference for P3 amplitude (p-value = 0.016), with higher amplitude for the left ear in all groups. In the LLAEP with tone burst stimulus, only the P2 and N2 latencies presented a significantly difference (P-value = 0.010 and P-value = 0.010, respectively), with lower latency for the group with severe OSA. In these same components, there was difference between the ears. A difference in the P2-N2 amplitude was found, with a lower amplitude for the group with severe OSA (p-value < 0.001). Conclusion: Individuals with OSA showed a progressive increase in the latency according to the severity of the disease in the component P3 in LLAEP for the speech stimulus, as well as lower amplitude in P2-N2 with tone burst stimulus for the severe OSA group, suggesting interference of the disease severity degree in the LLAEP. In general, individuals with severe OSA presented increased latencies and lower amplitudes in the LLAEP when compared to individuals without OSA
510

Avaliação da eficácia de aparelho intraoral no tratamento da apneia obstrutiva do sono em hospital de ensino / Evaluation of the effectiveness of oral appliance in the treatment of obstructive sleep apnea in teaching hospital

Ranieri, Ana Laura Polizel 23 February 2010 (has links)
INTRODUÇÃO: A apnéia obstrutiva do sono (AOS) é caracterizada como uma doença crônica, progressiva, incapacitante, com alta morbidade e mortalidade cardiovascular, sendo causada pela obstrução dinâmica repetitiva da via aérea superior (VAS). As repercussões geram necessidade de tratamento. Dentre os tratamentos disponíveis e com efetividade comprovada, há a opção de uso dos aparelhos intraorais. Neste estudo, avaliou-se a eficácia de um tipo de aparelho intraoral (AIO) monobloco, assim como suas complicações e intercorrências em longo prazo, em hospital de ensino. MÉTODOS: 20 pacientes participaram do presente estudo. Foram incluídos pacientes com diagnóstico polissonográfico prévio de AOS leve ou moderada (5 >IAH< 30), com idade até 60 anos, e não obesos. O critério de exclusão foi para pacientes em uso de medicamentos psicotrópicos, não condição oral para suporte do AIO e IMC e idade acima do proposto. Após 60 dias de uso do AIO realizou-se nova polissonografia (PSG), e acompanhamento pelo questionário RDC/TMD e ficha clínica EDOF/HC basal, 60 e 180 dias. RESULTADOS: Dentre os 20 pacientes, 11 eram do sexo masculino e nove do sexo feminino, com média de idade de 51 anos, e a média do IMC foi de 27,76. O índice de apnéia e hipopnéia (IAH) apresentou decréscimo de 19,23 para 7,51 eventos/hora de sono (p= 0,001). O eixo I e II do RDC/TMD não apresentou alterações significativas nos três momentos avaliados, porém o eixo II mostrou que os pacientes desta amostra apresentam maior grau de sintomas físicos e depressivos do que o padrão. CONCLUSÕES: No período estudado houve redução significativa do índice de apnéia e hipopnéia com o uso do aparelho intra-oral monobloco e foi eficaz total ou parcialmente no tratamento de 80% dos pacientes. As complicações não foram homogêneas e mostraram-se transitórias. / INTRODUCTION: Obstructive sleep apnea (OSA) is characterized as a chronic, progressive, disabling condition with high cardiovascular morbidity and mortality, and with repetitive episodes of upper airway (UA) obstruction. Its impact generates need for treatment. Among the treatments available and with demonstrated effectiveness, there is the option of using the oral appliances. In this study, we evaluated the effectiveness of a type of monoblock oral appliance (OA), as well as its complications and long-term complications in teaching hospital. METHODS: 20 patients participated in this study. We included patients with polysomnographic diagnosis of OSA prior mild or moderate (5> AHI <30), aged up to 60 years and not obese. The exclusion criteria were patients using psychotropic drugs, not oral condition to support the AIO and BMI and age above proposed. After 60 days of use of OA underwent a polysomnography (PSG) exam and follow-up by clinical record EDOF/HC and questionnaire RDC/TMD at baseline, 60 and 180 days. RESULTS: 11 male and nine female, mean age 51 years, and mean BMI was 27.76. The apnea-hypopnea index (AHI) showed a decrease of 19.23 to 7.51 events/hour of sleep (p = 0.001). Axis I and II of the RDC / TMD was not significantly changed in the three moments, but the axis II showed that patients in this sample have a higher degree of physical symptoms and depression than the standard. CONCLUSIONS: Oral appliance therapy for obstructive sleep apnea over the period reduced significantly the AHI and was totally or partially effective in treating 80% of patients. Complications were not homogeneous and were transient.

Page generated in 0.0302 seconds