Spelling suggestions: "subject:"oro"" "subject:"soro""
281 |
Uso do método do padrão interno em sistemas FIA e BIA e determinação simultânea de diclofenaco e codeína em formulações farmacêuticas por amperometria de múltiplos pulsos / Use of the internal standard method in FIA and BIA systems and determination of diclofenac and codeine in pharmaceutical formulations by multiple pulse amperometryGimenes, Denise Tofanello 25 July 2013 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / The present thesis demonstrates, for the first time, the possibility of using of the
internal standard method in FIA or BIA systems with amperometric detection. The
method allows to obtain accurate results in the presence of fluctuations in the system
parameters (injected volume, dispensing rate, ionic strength and accidental insertion of
air bubbles) and in the presence of contamination and/or gradual passivation of the
working electrode surface. Methods for determination of diclofenac (DCF) using FIA
with amperometric detection and simultaneous determination of DCF and codeine (CO)
by BIA with amperometric detection have also been developed.
The internal standard method was implemented in the flow injection analysis with
multiple pulse amperometric detection (FIA-MPA) system by applying a sequence of
potential pulses of the working electrode as a function of time. The analyte (+0.80
V/300ms) and internal standard (-0.05 V/400ms) were detected selectively, one at each
potential pulse. Significant improvements were obtained in the accuracy of the system
when the results before and after normalization (using the internal standard method),
were compared. The following errors were calculated, respectively, before and after
normalization of the results using the internal standard method. Change in flow rate
from 3.0 to 1.0 ml min-1 (-57% e < 1%); volume injection from 300 to 100 μL (-63%
and 3%); ionic strength from 0.60 to 0.77 mol L-1 (-44 and 0,2%) and before and after
the introduction of air bubbles into the system (-9,6% and 1,7%). A significant
improvement was also obtained in the correlation coefficient of the calibration curve in
the presence of problems of passivation or contamination of the working electrode. The correlation coefficient was calculated, respectively, as 0,975 and 0,998, before and after
the normalization of the results by the IS method.
The internal standard method was also applied to correct errors derived from the
injection procedure (dispensing rate and injected volume) in batch injection analysis
systems (BIA) with amperometric detection when disposable syringes were used. The
results obtained before and after normalization of the results by the IS method were the
following, respectively: repeatability test (RSD = 6.4 and 1.8%; n = 8), correlation
coefficients (R=0.954 and 0.997) and errors obtained in analysis of synthetic samples (E
= 9.4 ± 1.5 and 3.5 ± 0.7%; n = 8).
The determination of DCF by FIA-MPA was implemented by applying two
potential pulses to the BDD electrode using H2SO4 0.1 mol L-1 as supporting
electrolyte: (i) + 1.2 V / 50 ms for oxidation and quantification of DCF, and (ii) 0.0 V /
50 ms for constant electrochemical cleaning of the electrode surface. The system
showed good stability (RSD = 1.0%, n = 10) and high analytical frequency (135
injections h-1). The method showed a linear response between 5 and 50 μmol L-1 and the
detection and quantification limits were as 0.14 and 0.46 mmol L-1, respectively. The
proposed method was applied to determine of DCF in pharmaceutical formulations and
the obtained results were similar to those obtained by HPLC with a confidence level of
95%.
The simultaneous determination of DCF and CO was performed using the
following potential pulses: (i) +1.1 V / 50 ms: oxidation and quantification of DCF; (ii)
+1.4 V / 50 ms: simultaneous oxidation of DCF and CO, (iii) 0.0 V / 200 ms: for
constant electrochemical cleaning of the BDD electrode. The oxidation current from CO
was obtained by the difference between currents detected at 1.4 and 1.1 V by using a correction factor. The system showed good stability (RSD = 0.9% and 1.1 for DCF and
CO respectively, n = 10) and high analytical frequency (~ 300 injections h-1). The
method showed a linear response between 10 and 50 μmol L-1 for DCF and 7.1 and 35.7
μmol L-1 for CO. The LQ and LD were calculated, respectively, at 1.1 and 3.7 μmol L-1,
for DCF and 1.0 and 3.3 mol L-1 for CO. The proposed method was applied for
simultaneous determination of DCF and CO in pharmaceutical formulations and the
obtained results were similar to those obtained by HPLC with a confidence level of
95%.
Keywords: Multiple pulse amperometry, FIA, BIA, internal standard, simultaneous
analysis, boron doped diamond (BDD), codeine, diclofenac. / Esta tese apresenta, pela primeira vez, a possibilidade de usar o método do padrão
interno em sistemas FIA ou BIA com detecção amperométrica. O método permite a
obtenção de resultados precisos na presença de flutuações em parâmetros dos sistemas
(volume injetado, velocidade de injeção, força iônica e inserção acidental de bolhas de
ar) e na presença de contaminação e/ou passivação gradual do eletrodo de trabalho.
Métodos para determinação de diclofenaco (DCF) usando FIA com detecção
amperométrica e simultânea de DCF e codeína (CO) por BIA com detecção
amperométrica também foram desenvolvidos.
O método do padrão interno foi implementado no sistema de análise por injeção
em fluxo com detecção por amperometria de múltiplos pulsos (FIA-MPA) mediante a
aplicação de uma sequência de pulsos de potenciais ao eletrodo de trabalho em função
do tempo. O analito (+0,80 V/300ms) e o padrão interno (-0,05 V/400ms) foram
detectados seletivamente, um em cada pulso de potencial. Melhoras significativas foram
obtidas na precisão do método quando os resultados obtidos antes e após a normalização
(usando o método do padrão interno) foram comparados. As seguintes variações foram
calculadas, respectivamente, antes e após a normalização dos resultados usando o
método do padrão interno. Variação na velocidade de vazão de 3,0 para 1,0 mL min-1
(-57% e < 1%); no volume de injeção de 300 para 100 μL (-63% e 3%); força iônica de
0,60 para 0,77 mol L-1 (-44 e 0,2%) e antes e após a inserção de bolhas de ar no sistema
(-9,6% e 1,7%). Uma melhora significativa também foi obtida no coeficiente de correlação da curva de calibração na presença de problemas de passivação ou
contaminação do eletrodo de trabalho. O coeficiente de correlação foi calculado,
respectivamente, em 0,975 e 0,998, antes e após a normalização dos resultados pelo
método do PI.
O método do padrão interno também foi aplicado para corrigir erros em sistemas
de análise por injeção em batelada (BIA) com detecção amperométrica provenientes do
procedimento de injeção (velocidade de injeção e volume injetado) quando seringas
descartáveis foram utilizadas. Os resultados obtidos antes e após a normalização dos
resultados pelo método do PI foram os seguintes, respectivamente: estudo de
repetibilidade (DPR=6,4 e 1,8%; n = 8), coeficientes de correlação (R=0,954 e 0,997) e
erros obtidos na análise de amostras sintéticas (9,4 ± 1,5% e 3,5 ± 0,7; n = 8).
A determinação de DCF por FIA-MPA foi implementada através da aplicação de
dois pulsos de potenciais ao eletrodo de BDD em meio de H2SO4 0,1 mol L-1 como
eletrólito suporte: (i) +1,2 V / 50 ms para oxidação e quantificação do DCF e, (ii) 0,0 V
/ 50 ms para constante limpeza eletroquímica do eletrodo de trabalho. O sistema
apresentou boa estabilidade (RSD = 1,0%; n=10) e elevada frequência analítica (135
injeções h-1). O método apresentou resposta linear entre 5 e 50 μmol L-1 e os limites de
detecção e quantificação foram calculados em 0,14 e 0,46 μmol L-1, respectivamente. O
método proposto foi aplicado na determinação de DCF em formulações farmacêuticas e
os resultados obtidos foram similares ao obtidos por HPLC a um nível de confiança de
95%.
A determinação simultânea de DCF e CO foi realizada usando os seguintes pulsos
de potenciais: (i) +1,1 V / 50 ms: oxidação e quantificação de DCF; (ii) +1,4 V / 50 ms:
para oxidação simultânea de DCF e CO; (iii) 0,0 V / 200 ms: para constante limpeza
eletroquímica do eletrodo de BDD. A corrente de oxidação da CO foi obtida pela subtração entre as correntes detectadas em 1,4 e 1,1 V mediante uso de um fator de
correção. O sistema apresentou boa estabilidade (RSD= 1,1 e 0,9% para DCF e CO,
respectivamente, n=10) e elevada frequência analítica (~300 injeções h-1). O método
apresentou resposta linear entre 10 e 50 μmol L-1 para o DCF e entre 7,1 e 35,7 μmol L-1
para CO. O LD e o LQ foram calculados, respectivamente, em 1,1 e 3,7 μmol L-1, para
DCF e 1,0 e 3,3 μmol L-1 para CO. O método proposto foi aplicado na determinação
simultânea de DCF e CO em formulações farmacêuticas e os resultados obtidos foram
similares ao obtidos por HPLC a um nível de confiança de 95%. / Doutor em Química
|
282 |
Desenvolvimento de um método por ponto nuvem dos hormônios naturais E1 e E2 em amostras de urina e determinação por CLAE/EC utilizando eletrodo de diamante dopado com boro / Development of a cloud point method of E1 and E2 natural hormones from urine samples and determination by HPLC/EC using boron doped diamondAmorim, Kamila Pereira de 06 August 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2016-01-08T08:39:40Z
No. of bitstreams: 2
Dissertação - kamila Pereira de Amorim - 2015.pdf: 1653482 bytes, checksum: 57f33de27efd496be7b4807548727455 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-01-08T08:41:11Z (GMT) No. of bitstreams: 2
Dissertação - kamila Pereira de Amorim - 2015.pdf: 1653482 bytes, checksum: 57f33de27efd496be7b4807548727455 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-01-08T08:41:11Z (GMT). No. of bitstreams: 2
Dissertação - kamila Pereira de Amorim - 2015.pdf: 1653482 bytes, checksum: 57f33de27efd496be7b4807548727455 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2015-08-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Cloud point extraction method (CPE) was used for the determination of estrone (E1) and 17β-estradiol (E2) hormones in human urine. The combination of the electrochemical detection techniques with high-performance liquid chromatography (HPLC-EC) was used for the detection and quantification of these hormones. A boron doped diamond electrode (BDD) pretreated cathodically was used as electrode material for all electrochemical measurements. The optimized chromatographic parameters resulted in a mobile phase composition of KH2PO4 (0.01 mol L-1; pH 5.0) / ACN (72:28 V/V), flow 1.2 ml min-1. An applied potential for electrochemical detection of 1.0 V x Ag/AgCl (3.0 mol L-1) was selected from hydrodynamic voltammograms constructed for each hormone changing the potential between 0.3 V and 1.2 V x Ag/AgCl (3.0 mol L-1). Limits of detection (S/N = 3) of 500 ng mL-1 and limits of quantification of 800 ng mL-1 were obtained for both E1 and E2 hormones without any extraction process. Urine samples at pH 5.0 and 7.0 were investigated aiming the influence of pH on the efficiency of the CPE process, and the optimum results for the most current signal of the hormones was obtained at pH 7.0. Extractor solvent volumes were changed in the 0.5-2.5 mL range, and the optimum results were obtained when using 1.0 mL of Tergitol TMN-6 surfactant (10% aqueous solution). From the equation of the calibration curves obtained with and without the CPE procedure it was possible to determine the pre-concentration factor (FC) and all the other parameters involving the efficiency of CPE method. A comparison of the efficiency of CPE method with direct liquid-liquid extraction with the organic solvent CCl4 was carried out and the results showed that the CPE method was quite superior to liquid-liquid extraction. The validation of the method was carried out from intra-day recovery experiments and inter-day and evaluated the accuracy, precision and repeatability. The proposed method was applied to individual samples of urine of 1 man, 1 pregnant woman, 1 woman in fertile age, and 1woman in lactating stage. The values of the variation coefficients of the recovery percentages were lower than 15%. / Método de extração por ponto nuvem (EPN) foi usado para a determinação dos hormônios estrona (E1) e 17β-estradiol (E2) em urina humana. A combinação entre as técnicas de detecção eletroquímica e cromatografia líquida de alta eficiência (CLAE-EC) foi usada para a detecção e quantificação desses hormônios. Um eletrodo de diamante dopado com boro (DDB) pré-tratado catodicamente foi usado como material de eletrodo para todas as determinações eletroquímicas. Os parâmetros cromatográficos otimizados resultaram em uma composição de fase móvel de KH2PO4 (0,01 mol L-1; pH 5,0) / ACN (72:28 V/V) vazão de 1,2 mL min-1. Um potencial aplicado para a detecção eletroquímica de 1,0 V x Ag/AgCl (3 mol L-1) foi selecionado a partir de voltamogramas hidrodinâmicos construídos para cada hormônio variando-se o potencial entre 0,3 V e 1,2 V x Ag/AgCl (3,0 mol L-1). Limites de detecção (S/R = 3) de 500 ng mL-1 e limites de quantificação de 800 ng mL-1 foram obtidos para ambos os padrões dos hormônios E2 e E1 sem qualquer processo de extração. Amostras de urina em pH 5,0 e 7,0 foram investigadas quanto a influência do pH na eficiência do processo de extração, e o melhor resultado referente ao maior sinal de corrente dos hormônios foi obtido em pH 7,0. Os volumes de solvente extrator foram variados na faixa de 0,5-2,5 mL e o melhor resultado referente ao sinal de corrente dos hormônios foi obtido pelo uso de 1,0 mL de solução aquosa 10% do surfactante Tergitol TMN-6. A partir da equação da reta obtida das curvas analíticas, com e sem o procedimento de EPN, foi possível determinar o fator de pré-concentração (FC) e todos os demais parâmetros envolvendo a eficiência do método de EPN. Uma comparação sobre a eficiência dos métodos de EPN com extração direta líquido-líquido com o solvente orgânico CCl4 foi realizada e os resultados mostraram que método de EPN mostrou-se bastante superior a extração líquido-líquido. A validação do método foi feita a partir de ensaios de recuperação intra-dia e inter-dia, sendo avaliadas a exatidão, precisão e repetitividade. O método proposto foi aplicado em amostras individuais de urina de 1 homem, 1 mulher gestante, 1 mulher em idade fértil e 1 mulher lactante. Os valores dos coeficientes de variação das porcentagens de recuperação foram menores que 15%.
|
283 |
Comportamento eletroquímico de nitrofuranos em eletrodos de diamante dopado com boro-modelo para o mecanismo de ação de nitrocompostos com atividades antichagásica / Electrochemical behaviour of nitrofurans on highly boron doped diamond Electrodes-model for the action mechanism of the nitrocompounds with antichagasic activityMurilo Sérgio da Silva Julião 09 March 2007 (has links)
O comportamento eletroquímico do Nitrofural (NFZ) foi estudado em eletrodos de pasta de carbono, carbono vítreo e diamante altamente dopado com boro (EDADB) em tampão Britton-Robinson (BR) usando a voltametria cíclica. Os melhores resultados foram obtidos em EDADB, no qual foi possível estabilizar o radical aniônico (R-NO2•‾) em meio predominantemente aquoso, como também estudar a interação entre o R-NO2•‾ a glutationa (GSH), a L-cisteína (Cis) e o O2. Somente na superfície do EDADB, o NFZ foi diretamente reduzido à amina derivada (R-NH2) no intervalo de 2,02 ≤ pH ≤ 4,03 num processo envolvendo seis (6,0 ± 0,4) elétrons e seis prótons. Na faixa de 7,04 ≤ pH ≤ 12 e meio predominantemente aquoso, a etapa de redução desmembrou-se em seus dois componentes: a redução do NFZ ao nitro radical aniônico (R-NO2•‾) e posterior redução deste ao derivado hidroxilamínico (R-NHOH) em processos envolvendo um e três (3,1 ± 0,1) elétrons respectivamente. No sentido anódico da varredura dos voltamogramas cíclicos registrados em pH 8,06, observou-se a oxidação da hidroxilamina ao derivado nitroso (R-NO), num processo envolvendo 2 (1,7 ± 0,2) elétrons e 2 prótons. Além disto, um novo pico de oxidação não relatado na literatura em qualquer material de eletrodo foi detectado em pH ≤ 8,06, que foi observado não importando se o NFZ havia sido previamente reduzido ou não. O cálculo do número de elétrons, n, envolvido em cada etapa eletroquímica foi satisfatoriamente estimado usando-se a equação de Randles-Sevcik. Na presença de [Tiol] ≤ 3,7 x 10-2 mol L-1, o NFZ é reduzido ao aduto R-NO-Tiol em um processo eletroquímico envolvendo dois elétrons e dois prótons. Por outro lado, o O2 atua como um aceptor de R-NO2•‾ e a constante de equilíbrio para a transferência monoeletrônica do R-NO2•‾ para o oxigênio, kO2, é 60. O processo é catalítico e pode ser utilizado para a determinação analítica de NFZ na faixa de 9,9 x 10-7 ≤ [NFZ] ≤ 1,1 x 10-5 mol L-1 em pH 8,06, com sensibilidade amperométrica de 2,2 x 104 µA L mol-1 cm-2 e limite de detecção de 3,4 x 10-7 mol L-1. Os parâmetros analíticos foram similares aqueles obtidos em pH 4,0 usando a redução direta do NFZ à respectiva amina derivada em um processo envolvendo seis elétrons e seis prótons. A caracterização do processo de redução total do NFZ em meio aquoso e velocidades de varredura relativamente baixas, 100 mV s-1, somente foi possível devido às características superficiais intrínsecas do EDADB, o qual estabiliza o radical livre, R-NO2•‾, permitindo trabalhar numa ampla janela de potencial, sem haver perda do sinal de oxidação do R-NO2•‾. / The electrochemical behaviour of nitrofural (NFZ) at carbon paste, glassy carbon and highly boron doped diamond (HBDD) electrodes was studied in Britton- Robinson (BR) buffer using cyclic voltammetry. The best results were obtained at HBDD electrodes, in which it was possible to stabilize the radical anion (R-NO2•‾) in predominantly aqueous medium as well as to study the interaction between the radical anion and glutathione (GSH), L-cysteine (Cys), and O2. Only at HBDD surface, NFZ was directly reduced to the amine derivative (R-NH2) in the pH range of 2.02 to 4.03 in a process involving six (6.0 ± 0.4) electrons and six protons. In the range of pH 7.04 to 12 and, predominantly aqueous medium, the reduction step split into its two components: the reduction of NFZ to the nitro radical anion (R-NO2•‾) and reduction of R-NO2•‾ to hydroxylamine derivative (R--NHOH) in processes involving one and three (3.1 ± 0.1) electrons respectively. On the anodic scan of the cyclic voltammograms and at pH 8.06, it was observed the oxidation of the hydroxylamine to the nitroso derivative (R-NO), in a process involving 2 (1.7 ± 0.2) electrons and 2 protons. In addition and unreported in the literature on any electrode material, was the detection of a new oxidation peak at pH > 8.06, which was observed regardless of whether NFZ had been previously reduced or not. The calculation of n, number of electrons, involved in each electrochemical step was satisfactorily accomplished using the Randles-Sevcik equation. In presence of [Thiol] ≤ 3.7 x 10-2 mol L-1 NFZ is directly reduced to R-NO---Thiol adducts in an electrochemical process involving two electrons and two protons. On the other side, O2 acts as a R-NO2•‾ scavenger and the equilibrium constant for the electron transfer from nitro radical to oxygen, kO2, is 60. The process is catalytic and can be used to the analytical determination of NFZ in the range of 9.9 x 10-7 ≤ [NFZ] ≤ 1.1 x 10-5 mol L-1 at pH 8.0, with amperometric sensitivity of 2.2 x 104 µA L mol-1 cm-2 and detection limit of 3.4 x 10-7 mol L-1. The analytical parameters were similar to those obtained at pH 4.03 using the direct reduction of NFZ to the respective amine derivative in a process involving six electrons and six protons. The characterization of NFZ global reduction process in aqueous medium and at relative low scan rate, 100 mVs-1, was only possible due the intrinsic superficial characteristics of the HBDD electrode, which stabilize the R-NO2•‾ free radical, allowing to work in a large potential window, without losing the R-NO2•‾ oxidation signal.
|
284 |
[pt] DESENVOLVIMENTO DE MÉTODOS ELETROANALÍTICOS PARA A DETERMINAÇÃO DE FUNGICIDAS DA CLASSE DAS ESTROBILURINAS UTILIZANDO ELETRODOS DE FILME DE BISMUTO E DE DIAMANTE DOPADO COM BORO / [en] ELECTROANALYTICAL METHODS FOR THE DETERMINATION OF FUNGICIDES OF THE STROBILURIN CLASS USING THE BISMUTH FILM ELECTRODE AND THE BORON-DOPED DIAMOND29 November 2021 (has links)
[pt] O monitoramento de resíduos de pesticidas é extremamente importante e isso se dá pelo emprego de métodos analíticos adequados para avaliar a sua presença em compartimentos ambientais e a contaminação de alimentos com esses agentes. Os pesticidas da classe das estrobilurinas vêm se tornando os mais utilizados para o controle dos fungos e apesar da propagada baixa toxicidade e rápida degradação, estudos devem ser realizados para averiguar o nível de exposição dos humanos a tais substâncias. Estudos com as estrobilurinas (azoxistrobina, cresoxim-metílico, dimoxistrobina, fluoxastrobina, picoxistrobina, piraclostrobina e trifloxistrobina) utilizando o eletrodo de trabalho de diamante dopado com boro (DDB) foram realizados por voltametria cíclica e voltametria de onda quadrada (SWV) e indicaram dois picos de oxidação (varredura anódica) em potenciais distintos. Dados experimentais e da literatura permitiram supor que para cresoxim-metílico e dimoxistrobina o primeiro pico de oxidação tem um mecanismo irreversível com 2 mols de elétrons por mol de analito e o segundo pico de oxidação com mecanismo quase-reversível. Para picoxistrobina, os dois picos de oxidação são irreversíveis com 2 mols de elétrons por mol de analito. Para piraclostrobina os dois picos de oxidação são quase-reversíveis. Métodos por SWV foram desenvolvidos utilizando DDB para determinação de cresoxim-metílico, picoxistrobina e piraclostrobina. As varreduras anódicas foram feitas entre: +1000 a +1750 mV (medição do sinal em +1420 mV) para cresoxim-metílico; +1100 a +1800 mV (medição do sinal em +1450 mV) para picoxistrobina e +1050 a +2100 mV (medição do sinal em +1280 mV) para piraclostrobina. O eletrólito suporte foi tampão acetato (0,05 mol L-1; pH 4,0) para a determinação de cresoxim-metílico e piraclostrobina e tampão Britton-Robinson (0,04 mol L-1; pH 2,0) para a picoxistrobina. Resposta analítica linear para cresoxim-metílico foi do limite de quantificação, LOQ, (0,9 umol L-1 ou 0,27 mg L-1) até 34,0 μmol L-1 com R2> 0,999. Para picoxistrobina a faixa linear foi do LOQ (0,7 mol L-1 ou 0,25 mg L-1) a 20,0 μmol L-1 (R2> 0,994). Já para piraclostrobina a faixa linear foi do LOQ (0,8 μmol L-1 ou 0,32 mg L-1) a 20,0 μmol L-1 (R2> 0,991). Os métodos foram aplicados na análise de amostras de suco de uva (cresoxim-metílico e piraclostrobina) e águas naturais (picoxistrobina e piraclostrobina). As recuperações variaram de 91,6 a 105,3 porcento dependendo da estrobilurina. Os métodos propostos foram comparados com cromatografia líquida de alta eficiência (HPLC) e os resultados não indicaram diferença significativa entre eles. Amostras de suco de uva comercial foram fortificadas na concentração do limite máximo permitido pela legislação, sendo o analito pré-concentrado dez vezes por extração em fase sólida (SPE), com cartucho C18, obtendo-se recuperações entre 95,4 a 99,5 porcento dependendo da estrobilurina. Dados experimentais indicaram que não houve degradação térmica significativa para as estrobilurinas em soluções aquecidas a 60 °C durante 2 h. Não foi possível propor um perfil simples de cinética para degradação por exposição ao UV para o cresoxim-metílico. Para picoxistrobina e piraclostrobina, um modelo de cinética de segunda ordem pode ser atribuído para a degradação por exposição ao UV. Métodos com a abordagem de análise por injeção em batelada (BIA) com detecção amperométrica no eletrodo de DDB foram desenvolvidos para a determinação de dimoxistrobina e picoxistrobina em águas naturais. Os métodos apresentaram uma frequência de análise de 180 injeções h-1 (dimoxistrobina) e 108 injeções h-1 (picoxistrobina), e precisão satisfatória (abaixo de 5 porcento). Resposta analítica linear para dimoxistrobina foi de 1,3 μmol L-1 (0,41 mg L-1) a 60,0 μmol L-1 com R2> 0,999 e para picoxistrobina foi de 5,3 μmol L-1 (1,95 mg L-1) e 100,0 μmol L-1 (R2> 0,999). Valores de recuperação obtidos nas amostras de águas naturais fortificadas com os analitos foram entre 80,2 e 105,6 porcento dependendo do analito. Além disso, uma estratégia simples para detectar a presença de moléculas interferentes em amostras de água com base na amperometria de múltiplos pulsos foi apresentada com sucesso. Um método voltamétrico de redissolução anódica por pulso diferencial usando o eletrodo de filme de bismuto foi desenvolvido para a determinação de picoxistrobina em amostras de urina e águas naturais. O ciclo de medição começou com a aplicação de um potencial de deposição de -700 mV durante 60 s para a formação in situ do filme Bi e a acumulação do analito. A varredura de potencial foi no sentido anódico entre +790 e +1050 mV. Provou-se que, nas condições empregadas, uma quantidade significativa de filme de Bi ainda está presente na superfície do eletrodo de carbono vítreo após a varredura anódica, com uma velocidade de 40 mV s-1. A presença de Bi é fundamental para a acumulação e oxidação de picoxistrobina (pico máximo em +954 mV) durante redissolução. O eletrólito suporte foi HCl 1,0 mol L-1. Um procedimento de limpeza foi desenvolvido a fim de minimizar o efeito de memória. Resposta analítica linear para picoxistrobina foi observada de 2,8 μmol L-1 (1,0 mg L-1) até 19,0 μmol L-1 (R2> 0,994). SPE permitiu a pré-concentração do analito e eliminou as interferências nas amostras de urina. Recuperações de 89,3 a 104,8 porcento foram encontradas e a interferência das outras estrobilurinas ao método foram avaliadas. O método proposto foi comparado com HPLC e os resultados indicam que não houve diferença significativa entre eles. / [en] The monitoring of pesticide residues is extremely important and this is accomplished by the use of methods to assess their presence in environmental compartments and in food stuff contaminated with these agents. The pesticides of the strobilurin class have become the most widely used for fungi control and despite the low toxicity and rapid degradation, studies should be conducted to ascertain the level of human exposure to such substances. Studies with the strobilurin pesticides (azoxystrobin, kresoxim-methyl, dimoxystrobin, fluoxastrobin, picoxystrobin, pyraclostrobin and trifloxystrobin) were performed by cyclic voltammetry and square wave voltammetry (SWV) using the boron-doped diamond (BDD). Results indicated two oxidation peaks (anodic scan) at different potentials. Based on experimental data and literature it is assumed that for kresoxim-methyl and dimoxystrobin the first oxidation peak comes from an irreversible mechanism involvieng 2 moles of electrons per mole of analyte while the second oxidation peak is from a quasi-reversible mechanism. For picoxystrobin, the two oxidation peaks are from irreversible processes involving 2 moles of electrons per mole of analyte. For pyraclostrobin, the two oxidation peaks are from quasi-reversible processes. SWV methods were developed for determination of kresoxim-methyl, pyraclostrobin and picoxystrobin using the BDD. The anodic scans were made between: +1000 to +1750 mV (measured signal at +1420 mV) for kresoxim-methyl; +1100 to +1800 mV (measured signal at +1450 mV) for picoxystrobin and +1050 to +2100 mV (measured signal at +1280 mV) for pyraclostrobin. The supporting electrolyte was acetate buffer (0.05 mol L-1, pH 4.0) for the determination of kresoxim-methyl and pyraclostrobin and Britton-Robinson buffer (0.04 mol L-1, pH 2.0) to picoxystrobin. Linear analytical response to kresoxim-methyl was the limit of quantification, LOQ (0.9 μmol L-1 or 0.27 mg L-1) to 34.0 μmol L-1 with R2> 0.999. For picoxystrobin the linear range was from LOQ (0.7 μmol L-1 or 0.25 mg L-1) to 20.0 μmol L-1 (R2> 0.994). Pyraclostrobin presented linear range from LOQ (0.8 μmol L-1 and 0.32 mg L-1) to 20.0 μmol L-1 (R2> 0.991). The methods were applied in the analysis of grape juice samples (kresoxim-methyl and pyraclostrobin) and in natural waters (picoxystrobin and pyraclostrobin). The recoveries ranged from 91.6 to 105.3 percent depending on the strobilurin. The results obtained with the proposed methods were compared with the ones achieved by high performance liquid chromatography (HPLC) indicating no significant difference between them. Commercial grape juice samples were fortified at the maximum concentration allowed legislation and the analytes were pre-concentrated (tenfold) by solid phase extraction (SPE) in a C18 cartridge analyte Recoveries were between 95.4 to 99.5 percent depending on the strobilurin. Experimental data indicate that no significant thermal degradation occurred for strobilurins in solutions heated at 60 °C for 2 h. It was not possible to propose a simple kinetic profile for the UV degradation of kresoxim-methyl. However, for picoxystrobin and pyraclostrobin, a second-order kinetic model explains their degradation profile. Methods using batch injection analysis (BIA) with amperometric detection on a BDD electrode have also been developed for the determination of picoxystrobin and dimoxystrobin in natural waters. The methods showed an analytical frequency of 180 injections h-1 (dimoxystrobin) and 108 injections h-1 (picoxystrobin) and satisfactory precision (less than 5 percent). Linear analytical response for dimoxystrobin was from 1.3 μmol L-1 (0.41 mg L-1) to 60.0 μmol L-1 with R2> 0.999 while for picoxystrobin, the range was from 5.3 μmol L-1 (1.95 mg L-1) to 100.0 μmol L-1 (R2> 0.999). Recoveries achieved for analyte fortified water samples were between 80.2 and 105.6 percent depending on the analyte. In addition, a simple strategy to detect the presence of interfering molecules in water samples, based on multiple pulse amperometry, was successfully introduced. A stripping anodic differential pulse voltammetric method using the bismuth film electrode was developed for the determination picoxystrobin in urine samples and in natural waters. The measurement cycle started with the application of a deposition potential of -700 mV for 60 s for the in situ formation of the Bi film and for the accumulation of analyte. The potential was scanned in the anodic direction between +790 and +1050 mV. It has been proven that, under the conditions employed, a significant amount of Bi film is still present on the surface of the glassy carbon electrode after anodic sweep, with a speed of 40 mV s-1. The presence of Bi is essential for the accumulation and oxidation of picoxystrobin (maximum peak at +954 mV) during stripping. The supporting electrolyte was HCl 1.0 mol L-1. A cleaning procedure was developed to minimize the memory effect. Analytical linear response was observed for picoxystrobin from 2.8 μmol L-1 (1.0 mg L-1) to 19.0 μmol L-1 (R2> 0.994). SPE allowed the pre-concentration of the analyte and elimination of interferences from urine samples. Recoveries from 89.3 to 104.8 percent were found. Interference of other strobilurin the method were evaluated. The proposed method was compared with HPLC and the results indicate no significant difference between them.
|
285 |
Identificación de caracteres fisiológicos y moleculares para la tolerancia a estreses abióticos en portainjertos de cítricos tetraploidesRuiz Valdés, Marta 07 October 2017 (has links)
Tesis por compendio / [EN] Polyploidy is very common in higher plants and is one of the main forces driving evolution, as it leads to changes that may favor plant adaptation. In citrus, polyploid breeding has provided great advantage, enabling the development of new tetraploid (4x) rootstocks and triploid seedless varieties. Rootstock breeding programs aim to combine the characters of interest in a single genotype to provide the required tolerances to biotic and abiotic constraints. In Spain, the presence of citrus tristeza virus (CTV) and the abundance of calcareous and saline soils limit the number of suitable citrus rootstocks. Citrus breeding has been traditionally carried out by sexual hybridization but this method has limitations which are mainly imposed by their complex reproductive biology and their high heterozygosity. To overcome these restrictions, some breeding programs working at tetraploid level have been initiated to facilitate the development of new citrus rootstock ideotypes. The spontaneous appearance of autotetraploid plants in seedlings of apomictic citrus genotypes brings a relatively simple breeding method, offering the opportunity of evaluating their properties and selecting them as new rootstocks. The impact of genome duplication on citrus is variable between species and remains poorly described. To assess the usefulness of 4x citrus rootstocks it is required to evaluate the effect of genome duplication on stress physiology, tree vigor and agronomical behavior. Citrus protoplast fusion allows the somatic hybridization between sexually incompatible species, leading to combine the whole genomes of parents in a single genotype and adding complementary dominant characters, regardless of parental heterozygosity. The purpose of this thesis was to assess the potential interest of the 4x versions of the main rootstocks used in Spanish citrus industry, which are citrange Carrizo (Citrus sinensis (L.) Osb. × Poncirus trifoliata (L.) Raf.) (CC) and C. macrophylla W. (CM) and describe the anatomical, physiological and molecular determinants of the differences found. Additionally, the characterization of two allotetraploid somatic hybrids obtained by protoplast fusion from these parents was also performed, as a preliminary step for their possible use as rootstocks. Results show that 4xCC has a reducing effect on the size of orange trees without changing the productive efficiency or the fruit quality, effects that might contribute to increase the productivity and facilitate the orchard management. In both rootstocks, genome duplication modified the mineral composition in the leaf of the grafted variety and enhanced the salinity tolerance of seedlings. Boron uptake in excess conditions was reduced in 4xCC when compared to 2x, while this property was not observed in 4xCM. The salt and boron exclusion abilities are associated to lower transpiration rates, reduced root hydraulic conductivity and root anatomical changes observed in 4x roots. However, the ability of 4x CC and CM to cope with iron chlorosis is not different from the 2x genotypes. These 4x rootstocks might therefore provide smaller citrus tress more tolerant to certain stresses, while maintaining the general behavior of the diploid genotype. Furthermore, somatic hybrids differ from each other in their genome composition, indicating that losses and rearrangements of the genetic material occurred during the fusion process. Both inherited the tolerance to stem pitting caused by CTV from CC, are tolerant to iron chlorosis like CM and have a higher tolerance to salinity than CC. Thus, these hybrids have a great potential for Mediterranean citrus industry. The provided knowledge on the effects of genome duplication and somatic hybridization on the anatomy, physiology, agronomic performance and molecular biology of citrus rootstocks will be key for developing breeding programs that aim to address current and future needs of citrus industry. / [ES] La poliploidía es una característica muy común en plantas superiores y actúa como motor evolutivo promoviendo su adaptación. En cítricos, la mejora genética a nivel poliploide agiliza el desarrollo de portainjertos tetraploides (4x) y permite obtener variedades sin semilla triploides. El portainjerto es un elemento fundamental en la citricultura para proporcionar al cultivo la tolerancia a estreses bióticos y abióticos. En España, el alto contenido en caliza y sales de la mayoría de los suelos citrícolas y el virus de la tristeza de los cítricos (CTV) limitan en el número de portainjertos adecuados para el cultivo de cítricos. El desarrollo de nuevos portainjertos tiene como objetivo reunir en un genotipo las características de interés. La hibridación sexual ha sido el método tradicionalmente empleado, aunque en cítricos plantea inconvenientes debido a su compleja biología reproductiva y a su alta heterocigosidad. La autotetraploidía, que aparece espontáneamente en los cítricos apomícticos, posibilita la selección y evaluación de las variantes 4x de cada portainjerto. El efecto de la tetraploidía es variable entre las diferentes especies de cítricos y apenas ha sido descrito. Conocer su influencia sobre la fisiología y morfología de los cítricos permitiría valorar su utilidad agronómica. La alotetraploidía, obtenida mediante fusión de protoplastos, permite hibridar especies sexualmente incompatibles y reunir los genomas completos de los parentales, acumulando sus caracteres dominantes complementarios con independencia de la heterozigosidad. El propósito de ésta tesis ha sido evaluar las variantes 4x de los portainjertos más utilizados en España, citrange Carrizo (Citrus sinensis (L.) Osb. × Poncirus trifoliata (L.) Raf.) (CC) y C. macrophylla (CM) para valorar su utilidad agronómica y describir sus propiedades. Además se han caracterizado dos híbridos alotetraploides obtenidos mediante fusión de protoplastos de CM y CC para valorar su posible utilización como portainjertos para la citricultura mediterránea. La tetraploidía en CC y CM modifica la composición mineral foliar de la variedad injertada y mejora la tolerancia de éstas plantas a la salinidad, mientras que la capacidad de hacer frente a la clorosis férrica no difiere entre ploidías en éstos portainjertos. El portainjerto CC4x ejerce un efecto reductor del tamaño de copa en árboles de naranjo sin modificar su eficiencia productiva ni la calidad del fruto y reduce la absorción y transporte de boro a la variedad injertada en condiciones de exceso, mejorando su tolerancia. La mayor capacidad de exclusión de sales y boro en las plantas 4x se relaciona con su menor transpiración. En CC interviene también en este comportamiento la menor conductancia hidráulica de las raíces 4x inducida por sus modificaciones anatómicas. Los híbridos alotetraploides obtenidos mediante fusión de protoplastos de CC y CM difieren en la composición de su genoma, indicando que se han producido pérdidas puntuales y reorganizaciones durante el proceso de fusión. Ambos reúnen los genomas nucleares parentales, han heredado de CC la tolerancia a las acanaladuras en la madera causadas por CTV, son similares a CM en su tolerancia a la clorosis férrica y manifiestan mayor tolerancia a la salinidad que CC. Por ello, reúnen características de gran interés para la citricultura mediterránea. La evaluación y selección de portainjertos 4x permitiría obtener árboles más pequeños y más tolerantes a ciertos estreses que mantengan el comportamiento general ya conocido de los diploides originales. La reducción del tamaño de copa contribuiría a mejorar el rendimiento productivo y a facilitar el manejo de las plantaciones citrícolas. El conocimiento generado sobre los efectos de la tetraploidización y de la hibridación somática en la anatomía, fisiología, comportamiento agronómico y genética de los portainjertos de cítricos ser / [CA] La poliploïdia és molt comuna en plantes superiors i es un dels principals motors evolutius per promoure canvis que afavoreixen la adaptació. En cítrics, la millora genètica a nivell poliploide ha contribuït agilitzant el desenvolupament de nous portaempelts tetraploides (4x) i de varietats sense llavors triploides. En Espanya, el virus de la tristesa dels cítrics (CTV) i l'alt contingut salí i calcari de la majoria dels sols limiten el numere de portaempelts adequats per al cultiu. La millora de portaempelts de cítrics té l'objectiu de reunir el major numere de característiques d'interés en un únic cultivar. La millora genètica tradicional de cítrics, duta a terme mitjançant hibridació sexual, planteja inconvenients deguts a la seua complexa biologia reproductiva i a l'alta heterocigositat. Per aixó s'han iniciat programes de millora de portaempelts a nivell 4x, amb l'objectiu d'agilitzar el seu desenvolupament. La autotetraploïdia, que apareix de manera espontània en especies apomíctiques de cítrics, permet seleccionar les variants 4x dels portaempelts, com un mètode de millora relativament senzill. L'efecte de la tetraploïdia és variable entre les espècies de cítrics i la seua incidència a penes havia sigut descrita. Conéixer la seua repercussió en la tolerància a estressos i el vigor de l'arbre permetria avaluar la utilitat de les versions 4x de cada portaempelt. D'altra banda, l'al¿lotetraploïdia, obtinguda mitjançant la fusió de protoplastos, possibilita l'obtenció d'híbrids d'espècies sexualment incompatibles i reunir en una sola hibridació els genomes complets de les parentals d'interés, permetent l'addició de caràcters dominants complementaris amb independència de l'heterozigositat dels parentals. La finalitat d'esta tesi ha sigut avaluar les propietats d'interés agronòmic de les variants 4x dels portaempelts més utilitzats en la citricultura española, citrange Carrizo (Citrus sinensis (L.) Osb. × Poncirus trifoliata (L.) Raf.) (CC) i C. macrophylla (CM), per valorar la seua utilitat i descriure els determinants de les diferències trobades. A més a més, s'ha pretés realitzar una caracterització molecular i fisiològica de dos híbrids al¿lotetraploides obtinguts de la fusió de protoplastos de CM i CC, com un pas previ per a la seua possible utilització com a portaempelts. El portaempelt CC4x exerceix un efecte reductor de la grandària de copa en arbres de taronger sense modificar l'eficiència productiva ni la qualitat del fruit. Este caràcter milloraría el rendiment productiu i a facilitaría el maneig de les plantacions citricoles. En els dos portaempelts estudiats, la tetraploïdia modifica la composició mineral foliar de la varietat empeltada i proporciona major tolerancia a la salinitat. En CC, la tetraploïdia redueix l'absorció del boro en excés, metre que esta propietat no s'ha observat en CM4x. La menor absorció del boro i l'exclusió del clorur es troben associades a la menor transpiració, a la reduïda conductivitat hidràulica i a les característiques anatòmiques de les arrels 4x. No obstant això, la tolerancia a la clorosi fèrrica no difereix entre ploidíes en estos portaempelts. La selecció de portaempelts 4x permetria obtenir arbres més menuts i més tolerants a certs estressos que mantenen el comportament ja conegut, de la variant diploide. Per la seua banda, els híbrids somàtics difereixen en la composició del genoma, indicant que s'han produït reorganitzacions i pèrdues puntuals durant el procés de fusió. Els dos han heretat de CC la tolerància a les estries en la fusta provocades per CTV, son tolerants a la clorosi fèrrica com CM i toleren la salinitat millor que CC. Per tot, reuneixen un conjunt de característiques de gran interés potencial per a la citricultura mediterrània. El coneixement generat en esta tesi serà de gran utilitat en els programes de millora basades en necessitats actuals i futures. / Ruiz Valdés, M. (2016). Identificación de caracteres fisiológicos y moleculares para la tolerancia a estreses abióticos en portainjertos de cítricos tetraploides [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/73725 / Compendio
|
286 |
[pt] PROPRIEDADES REOLÓGICAS E TÉRMICAS DE DISPERSÕES MULTIFUNCIONAIS DE NITRETO DE BORO HEXAGONAL À BASE DE GOMA XANTANA PARA USO EM FLUIDOS DE PERFURAÇÃO À BASE DE ÁGUA / [en] RHEOLOGICAL AND THERMAL PROPERTIES OF MULTIFUNCTIONAL HEXAGONAL BORON NITRIDE DISPERSIONS BASED IN XANTHAN GUM FOR USE IN WATER-BASED DRILLING FLUIDSYAGO CHAMOUN FERREIRA SOARES 16 December 2024 (has links)
[pt] Nas últimas décadas, a procura por petróleo e gás aumentou, levando à identificação de novos campos petrolíferos em ambientes de reservatórios desafiadores, caracterizados por condições de alta pressão e alta temperatura (HPHT). O desenvolvimento de fluidos de perfuração de base aquosa de alto desempenho com propriedades personalizadas visa aprimorar os processos de extração na indústria petrolífera e reduzir a contaminação ambiental causada principalmente por fluidos à base de óleo. Este estudo tem como objetivo investigar como variações em parâmetros como temperatura, pressão e concentração impactam nas propriedades térmicas e reológicas de suspensões de goma xantana com nanoestruturas de nitreto de boro hexagonal oxidado (hBN-oxi). A condutividade térmica foi significativamente aumentada pela adição de nanopartículas de hBN-oxi (suspensão de 6,0 por cento em peso) ao fluido base, atingindo um aumento de até 12 por cento a 70 graus C. Estas nanoestruturas desempenharam um papel crucial na preservação da condutividade térmica das suspensões de goma xantana, mesmo em temperaturas elevadas. A suspensão com concentração mais alta apresentou tensão limite de escoamento e quando submetida a altas taxas de cisalhamento, sofreu uma queda de viscosidade de apenas 16 por cento a 80 graus C. Estes efeitos adversos da temperatura e pressão sobre a viscosidade foram mitigados pela interação entre a matriz polimérica e o hBN-oxi. No geral, o estudo destacou o potencial do nitreto de boro como nanoaditivo para fluidos de perfuração convencionais, mostrando que formulações adequadamente projetadas podem melhorar o desempenho mesmo em condições desafiadoras sem causar danos ao meio ambiente, graças à alta estabilidade térmica e química do material. / [en] In recent decades, the demand for oil and gas has surged, prompting the
identification of new oil fields in challenging reservoir environments those
characterized by high-pressure and high-temperature (HPHT) conditions. The
development of high-performance aqueous-based drilling fluids with tailored
properties aims to enhance extraction processes in the oil industry and reducing
environmental contamination mainly caused by oil-based fluids. This study aims to
investigate how variations in parameters such as temperature, pressure and
concentration impact the thermal and rheological properties of xanthan gum
suspensions with oxidized hexagonal boron nitride (hBN-oxi) nanostructures. The
thermal conductivity was significantly increased by the addition of hBN-oxi
nanoparticles (6.0 wt percent suspension) to the base fluid, reaching an increase of up to
12 percent at 70 degrees C. These nanostructures played a crucial role in preserving the thermal
conductivity of xanthan gum suspensions even at elevated temperatures. The
presence of nanoparticles at the highest concentration induced a yield stress in the
fluid and when subjected to high shear rates, experienced a viscosity drop of only
16 percent at 80 degrees C. These adverse effects of temperature and pressure on viscosity were
mitigated by the interaction between the polymer matrix and hBN-oxi. Overall, the
study highlighted the potential of boron nitride as a nanoadditive for conventional
drilling fluids, showing that properly designed formulations can improve
performance even in challenging conditions without causing harm to the
environment, thanks to the material s high thermal and chemical stability.
|
287 |
Estudos de técnicas de feixes iônicos para a quantificação do elemento químico boro / Study of boron quantification using ion beam analysis techniques.Moro, Marcos Vinicius 16 May 2013 (has links)
Neste trabalho, estudamos e aplicamos técnicas analíticas com feixes iônicos para a identificação e quantificação do elemento químico Boro em amostras de Boro depositado sobre Níquel 11B/Ni, sobre Silício B/Si e em amostras de Silício Grau Metalúrgico - SiGM. Estas últimas foram fornecidas pelo grupo de metalurgia do Instituto de Pesquisas Tecnológicas (IPT). Especificamente, as seguintes técnicas analíticas foram utilizadas: Nuclear Reaction Analysis - NRA, Elastic Recoil Detection Analysis - ERDA e Secondary Ion Mass Spectrometry - SIMS. Nas amostras de B/Ni e B/Si, as concentrações foram obtidas com medidas de NRA, ERDA e SIMS. Também foi abordado quais dentre essas três técnicas apresentam menor limite de deteção e menor incerteza para a quantificação de Boro. Usando a reação nuclear 11B(p,a0)8Be, foi possível calcular a sua seção de choque diferencial para ângulo de espalhamento theta=170, cujo resultado, para este ângulo específico, é inédito na literatura. As amostras de SiGM foram analisadas com a técnica SIMS e comparadas com medidas de Inductively Coupled Plasma - ICP realizadas pelo grupo do IPT. Uma vez que técnicas nucleares podem ser consideradas absolutas, concluímos que as medidas de ICP apresentaram dados compatíveis com as medidas SIMS, e que o grupo de metalurgia do IPT está medindo as concentrações de Boro em suas amostras de SiGM corretamente por meio de ICP. Uma reta de calibração entre medidas SIMSxICP foi construída, que poderá servir como um guia para futuras quantificações de Boro com ICP feitas pelo grupo de metalurgia do IPT. / In this work we investigated the use of analytical techniques based on ion beams in the quantification of Boron in many kinds of samples. Specifically, we applied techniques such Nuclear Reaction Analysis (NRA), Elastic Recoil Detection Analysis (ERDA) and Secondary Ion Mass Spectrometry (SIMS) to 11B/Ni and B/Si samples to measure the boron concentration. We also discuss and show what technique has a better detection limit and lower uncertainty. For the first time in the literature, we obtained the cross section for the $^{11}B(p,\\alpha_0){^8}Be$ nuclear reaction in the energy range from 1.6 up to 2.0 MeV in theta = 170 scattering angle. The SIMS technique was applied to analise samples of metallurgical grade silicon (SiGM) from Metallurgy Group of Instituto de Pesquisas Tecnologicas (IPT) to check the Inductively Coupled Plasma (ICP) measurements carried out by the IPT. Moreover, it was possible to build a calibration curve between SIMS and ICP measurements, that can be used to help of Metallurgy Group with futures ICP\'s measurements.
|
288 |
Degradação eletroquímica/química dos corantes têxteis Reativo Azul 19 e Reativo Preto 5 utilizando eletrodos de diamante dopado com boro e H2O2 eletrogerado em eletrodo de carbono vítreo reticulado / Electrochemical/chemical degradation of textile dyes Reactive Blue 19 and Reactive Black 5 using boron doped diamond electrodes and H2O2 electrogenerated in reticulated vitreous carbon electrodeVasconcelos, Vanessa Moura 11 September 2015 (has links)
A problemática envolvendo os efluentes têxteis decorre principalmente da elevada coloração que apresentam, devido à presença de corantes que além de serem quimicamente estáveis, podem ser tóxicos e/ou carcinogênicos. Logo, quando são descartados in natura no meio ambiente causam problemas estéticos e, sobretudo, ambientais mesmo em baixas concentrações, além da possibilidade de serem nocivos à saúde humana e dos animais. Neste contexto, o objetivo deste trabalho foi estudar a degradação eletroquímica de dois corantes têxteis, Reativo Azul 19 (RA-19) e o Reativo Preto 5 (RP-5) via Oxidação Anódica (OA), utilizando ânodos de Diamante Dopado com Boro (DDB) suportados em titânio ou em nióbio, via processo Eletro-Fenton (EF) e pela combinação dos processos com H2O2 eletrogerado e OA (CP), usando um eletrodo de Carbono Vítreo Reticulado (CVR) como cátodo. As degradações foram realizadas em célula eletroquímica de um compartimento e em reator de fluxo do tipo filtro-prensa com dois compartimentos. A eficiência das degradações foi monitorada pelas técnicas de espectrofotometria no UV-VIS, Cromatografia Líquida de Alta Eficiência (CLAE) e análise do teor de Carbono Orgânico Total (COT). As variáveis estudadas foram densidade de corrente (10-100 mA cm-2 em célula e 4-41 mA cm-2 em reator), dopagem do eletrodo de DDB/Ti (5.000 e 15.000 ppm B/C), concentração inicial dos íons Fe2+ (0-0,10 mmol L-1) e dos corantes (10-250 mg L-1). As degradações dos corantes apresentaram uma cinética de pseudo ordem zero; exceto quando o corante RP-5 foi degradado pelo processo EF, sendo o melhor ajuste ao modelo de pseudo primeira ordem. Além disso, em iguais condições eletroquímicas o corante RP-5 foi degradado em menor tempo em relação ao RA-19; sendo que em todos os processos estudados os corantes foram totalmente removidos. Considerando a OA em célula com os eletrodos de DDB/Ti, a degradação foi positivamente influenciada pelo aumento da densidade de corrente e dopagem do eletrodo, especialmente em relação a cinética. Além disso, os corantes RA-19 e RP-5 foram completamente removidos em 35 e 50 min de eletrólise quando 100 mA cm-2 foi aplicada ao eletrodo de DDB/Ti dopado com 15.000 ppm relação B/C. Em 2 h, 37% em mineralização foi observado para ambos os corantes e a toxicidade do RA-19 diminuiu contra as bactérias Vibrio fischeri. Ainda nessa condição total mineralização foi alcançada após 8 h de degradação. A remoção de COT foi favorecida utilizando o reator contendo os eletrodos de DDB/Nb e CVR ao invés da célula eletroquímica, chegando a percentuais de 84 e 82% em 30 e 90 min para os corantes RA-19 e RP-5 que foram removidos em 7,5 e 5 min, respectivamente, quando a densidade de 41 mA cm-2 foi aplicada ao DDB/Nb durante a degradação via exclusivamente OA. Entre os processos realizados no reator, o EF foi o energeticamente mais favorável, promovendo remoção em COT de 60 e 74% para os corantes RA-19 e RP-5 com consumo energético de 204 e 208 kWh kg-1, além disso, a completa remoção dos corantes ocorreu em 15 e 7,5 min, respectivamente, quando o eletrólito continha íons Fe2+ na concentração de 0,10 mmol L-1 e aplicando-se -0,4 V vs Ag/AgCl ao eletrodo de CVR. Na degradação os corantes via CP o RA-19 e RP-5 foram completamente removidos em 30 e 15 min com mineralização de 72 e 82% em 90 min associada a consumos energéticos de 562 e 745 kWh kg-1, respectivamente, quando 41 mA cm-2 foi aplicada ao DDB/Nb. Por fim, concluiu-se que os resultados das degradações dos corantes foram promissores, já que rápida remoção dos corantes foi observada, além da parcial mineralização. Logo os processos propostos podem ser aplicados na remoção dos corantes em água; sendo necessários realizar mais estudos, principalmente em relação ao material eletródico e configuração do sistema eletroquímico visando a aplicação industrial. / The main problem involving the textile wastewater is theirs high coloration since they present dyes, which are chemically stable and can be toxic and/or carcinogenic. Therefore, when the textile wastewater are discarded in nature in the environment, even in low concentrations, they may cause not only aesthetic and environmental problems, but also can be harmful to human and animal health. In this context, the aim of the study was to evaluate the electrochemical degradation of two textile dyes, Reactive Blue 19 (RB-19) and Black 5 (RB-5) via Anodic Oxidation (AO) using as anodes Boron Doped Diamond electrodes (BDD) supported on titanium or niobium, via Electro-Fenton (EF) process and by combination of processes with electrogenerated H2O2 and AO (CP) using a Reticulated Vitreous Carbon electrode (RVC) as cathode. The degradations assays were carried out in an electrochemical cell with one compartment and in a filter-press flow reactor with two compartments. The efficiency of degradation was monitored by UV-VIS spectrophotometry, High Performance Liquid Chromatography (HPLC) and analysis of Total Organic Carbon (TOC). The variables studied were current density (10-100 mA cm-2 for cell and 4-41 mA cm-2 for reactor), doping of the BDD/Ti electrodes (5,000 e 15,000 ppm B/C), initial concentration of the Fe2+ ions (0-0,10 mmol L-1) and dyes (10-250 mg L-1). The kinetic results showed that the removal of dyes followed the model of pseudo zero order; except when the RB-5 dye was degraded by EF process, which the best fitted was to pseudo first order model. Furthermore, for equal conditions the RB-5 was degraded in less time in comparison to the RB-19. In addition, the dyes were fully removed in all the processes studied. Regarding the AO in cell with BDD/Ti, the degradation was positively influenced by the increasing in current density and doping of the electrode, primarily the kinetics parameters. In addition, total removal of RB-19 and RB-5 was achieved in 35 and 50 min of electrolysis when 100 mA cm-2 was applied to the electrode doped with 15,000 ppm ratio B/C. In 2 h, 37% in mineralization was attained for both dyes and the toxicity effect of the RB-19 decreased against the bacteria Vibrio fischeri. In this condition, total TOC removed was also reached after 8 h. The TOC removal was enhanced using the reactor fitted with BDD/Nb and RVC instead of the electrochemical cell, achieving TOC removal of 84 and 82% in 30 and 90 min for RB-19 and RB-5 which were removed in 7.5 and 5 min, respectively, when 41 mA cm-2 was applied to the BDD/Nb in the degradation exclusively via AO. Among the processes carried out in the reactor, the EF was the energetically most favourable since TOC removal of 60 and 74% for RB-19 and RB-5 with energy consumption of 204 and 208 kWh kg-1 were noted. In addition, the RB-19 and RB-5 were completely removed in 15 and 7.5 min, respectively, when the electrolyte containing 0.10 mmol L-1 of Fe2+ ions and -0.4 V vs Ag/AgCl was applied to CVR electrode. The combination of processes with electrogenerated H2O2 and AO for degradation of the dyes removed the RB-19 and RB-5 in 30 and 15 min with mineralization of 71.6 and 81.8% in 90 min associated to energy consumptions of 562 and 745 kWh kg-1 respectively, when 41 mA cm-2 was applied to BDD/Nb. Therefore, the degradation results of the dyes were promised since quickly removal of the dyes and partial mineralization were observed hence the proposed processes could be used to remove the dyes from water. However, more studies are needed to enable an industrial application, especially regarding the electrode material and configuration of the electrochemical system.
|
289 |
Estudos de técnicas de feixes iônicos para a quantificação do elemento químico boro / Study of boron quantification using ion beam analysis techniques.Marcos Vinicius Moro 16 May 2013 (has links)
Neste trabalho, estudamos e aplicamos técnicas analíticas com feixes iônicos para a identificação e quantificação do elemento químico Boro em amostras de Boro depositado sobre Níquel 11B/Ni, sobre Silício B/Si e em amostras de Silício Grau Metalúrgico - SiGM. Estas últimas foram fornecidas pelo grupo de metalurgia do Instituto de Pesquisas Tecnológicas (IPT). Especificamente, as seguintes técnicas analíticas foram utilizadas: Nuclear Reaction Analysis - NRA, Elastic Recoil Detection Analysis - ERDA e Secondary Ion Mass Spectrometry - SIMS. Nas amostras de B/Ni e B/Si, as concentrações foram obtidas com medidas de NRA, ERDA e SIMS. Também foi abordado quais dentre essas três técnicas apresentam menor limite de deteção e menor incerteza para a quantificação de Boro. Usando a reação nuclear 11B(p,a0)8Be, foi possível calcular a sua seção de choque diferencial para ângulo de espalhamento theta=170, cujo resultado, para este ângulo específico, é inédito na literatura. As amostras de SiGM foram analisadas com a técnica SIMS e comparadas com medidas de Inductively Coupled Plasma - ICP realizadas pelo grupo do IPT. Uma vez que técnicas nucleares podem ser consideradas absolutas, concluímos que as medidas de ICP apresentaram dados compatíveis com as medidas SIMS, e que o grupo de metalurgia do IPT está medindo as concentrações de Boro em suas amostras de SiGM corretamente por meio de ICP. Uma reta de calibração entre medidas SIMSxICP foi construída, que poderá servir como um guia para futuras quantificações de Boro com ICP feitas pelo grupo de metalurgia do IPT. / In this work we investigated the use of analytical techniques based on ion beams in the quantification of Boron in many kinds of samples. Specifically, we applied techniques such Nuclear Reaction Analysis (NRA), Elastic Recoil Detection Analysis (ERDA) and Secondary Ion Mass Spectrometry (SIMS) to 11B/Ni and B/Si samples to measure the boron concentration. We also discuss and show what technique has a better detection limit and lower uncertainty. For the first time in the literature, we obtained the cross section for the $^{11}B(p,\\alpha_0){^8}Be$ nuclear reaction in the energy range from 1.6 up to 2.0 MeV in theta = 170 scattering angle. The SIMS technique was applied to analise samples of metallurgical grade silicon (SiGM) from Metallurgy Group of Instituto de Pesquisas Tecnologicas (IPT) to check the Inductively Coupled Plasma (ICP) measurements carried out by the IPT. Moreover, it was possible to build a calibration curve between SIMS and ICP measurements, that can be used to help of Metallurgy Group with futures ICP\'s measurements.
|
290 |
Degradação eletroquímica/química dos corantes têxteis Reativo Azul 19 e Reativo Preto 5 utilizando eletrodos de diamante dopado com boro e H2O2 eletrogerado em eletrodo de carbono vítreo reticulado / Electrochemical/chemical degradation of textile dyes Reactive Blue 19 and Reactive Black 5 using boron doped diamond electrodes and H2O2 electrogenerated in reticulated vitreous carbon electrodeVanessa Moura Vasconcelos 11 September 2015 (has links)
A problemática envolvendo os efluentes têxteis decorre principalmente da elevada coloração que apresentam, devido à presença de corantes que além de serem quimicamente estáveis, podem ser tóxicos e/ou carcinogênicos. Logo, quando são descartados in natura no meio ambiente causam problemas estéticos e, sobretudo, ambientais mesmo em baixas concentrações, além da possibilidade de serem nocivos à saúde humana e dos animais. Neste contexto, o objetivo deste trabalho foi estudar a degradação eletroquímica de dois corantes têxteis, Reativo Azul 19 (RA-19) e o Reativo Preto 5 (RP-5) via Oxidação Anódica (OA), utilizando ânodos de Diamante Dopado com Boro (DDB) suportados em titânio ou em nióbio, via processo Eletro-Fenton (EF) e pela combinação dos processos com H2O2 eletrogerado e OA (CP), usando um eletrodo de Carbono Vítreo Reticulado (CVR) como cátodo. As degradações foram realizadas em célula eletroquímica de um compartimento e em reator de fluxo do tipo filtro-prensa com dois compartimentos. A eficiência das degradações foi monitorada pelas técnicas de espectrofotometria no UV-VIS, Cromatografia Líquida de Alta Eficiência (CLAE) e análise do teor de Carbono Orgânico Total (COT). As variáveis estudadas foram densidade de corrente (10-100 mA cm-2 em célula e 4-41 mA cm-2 em reator), dopagem do eletrodo de DDB/Ti (5.000 e 15.000 ppm B/C), concentração inicial dos íons Fe2+ (0-0,10 mmol L-1) e dos corantes (10-250 mg L-1). As degradações dos corantes apresentaram uma cinética de pseudo ordem zero; exceto quando o corante RP-5 foi degradado pelo processo EF, sendo o melhor ajuste ao modelo de pseudo primeira ordem. Além disso, em iguais condições eletroquímicas o corante RP-5 foi degradado em menor tempo em relação ao RA-19; sendo que em todos os processos estudados os corantes foram totalmente removidos. Considerando a OA em célula com os eletrodos de DDB/Ti, a degradação foi positivamente influenciada pelo aumento da densidade de corrente e dopagem do eletrodo, especialmente em relação a cinética. Além disso, os corantes RA-19 e RP-5 foram completamente removidos em 35 e 50 min de eletrólise quando 100 mA cm-2 foi aplicada ao eletrodo de DDB/Ti dopado com 15.000 ppm relação B/C. Em 2 h, 37% em mineralização foi observado para ambos os corantes e a toxicidade do RA-19 diminuiu contra as bactérias Vibrio fischeri. Ainda nessa condição total mineralização foi alcançada após 8 h de degradação. A remoção de COT foi favorecida utilizando o reator contendo os eletrodos de DDB/Nb e CVR ao invés da célula eletroquímica, chegando a percentuais de 84 e 82% em 30 e 90 min para os corantes RA-19 e RP-5 que foram removidos em 7,5 e 5 min, respectivamente, quando a densidade de 41 mA cm-2 foi aplicada ao DDB/Nb durante a degradação via exclusivamente OA. Entre os processos realizados no reator, o EF foi o energeticamente mais favorável, promovendo remoção em COT de 60 e 74% para os corantes RA-19 e RP-5 com consumo energético de 204 e 208 kWh kg-1, além disso, a completa remoção dos corantes ocorreu em 15 e 7,5 min, respectivamente, quando o eletrólito continha íons Fe2+ na concentração de 0,10 mmol L-1 e aplicando-se -0,4 V vs Ag/AgCl ao eletrodo de CVR. Na degradação os corantes via CP o RA-19 e RP-5 foram completamente removidos em 30 e 15 min com mineralização de 72 e 82% em 90 min associada a consumos energéticos de 562 e 745 kWh kg-1, respectivamente, quando 41 mA cm-2 foi aplicada ao DDB/Nb. Por fim, concluiu-se que os resultados das degradações dos corantes foram promissores, já que rápida remoção dos corantes foi observada, além da parcial mineralização. Logo os processos propostos podem ser aplicados na remoção dos corantes em água; sendo necessários realizar mais estudos, principalmente em relação ao material eletródico e configuração do sistema eletroquímico visando a aplicação industrial. / The main problem involving the textile wastewater is theirs high coloration since they present dyes, which are chemically stable and can be toxic and/or carcinogenic. Therefore, when the textile wastewater are discarded in nature in the environment, even in low concentrations, they may cause not only aesthetic and environmental problems, but also can be harmful to human and animal health. In this context, the aim of the study was to evaluate the electrochemical degradation of two textile dyes, Reactive Blue 19 (RB-19) and Black 5 (RB-5) via Anodic Oxidation (AO) using as anodes Boron Doped Diamond electrodes (BDD) supported on titanium or niobium, via Electro-Fenton (EF) process and by combination of processes with electrogenerated H2O2 and AO (CP) using a Reticulated Vitreous Carbon electrode (RVC) as cathode. The degradations assays were carried out in an electrochemical cell with one compartment and in a filter-press flow reactor with two compartments. The efficiency of degradation was monitored by UV-VIS spectrophotometry, High Performance Liquid Chromatography (HPLC) and analysis of Total Organic Carbon (TOC). The variables studied were current density (10-100 mA cm-2 for cell and 4-41 mA cm-2 for reactor), doping of the BDD/Ti electrodes (5,000 e 15,000 ppm B/C), initial concentration of the Fe2+ ions (0-0,10 mmol L-1) and dyes (10-250 mg L-1). The kinetic results showed that the removal of dyes followed the model of pseudo zero order; except when the RB-5 dye was degraded by EF process, which the best fitted was to pseudo first order model. Furthermore, for equal conditions the RB-5 was degraded in less time in comparison to the RB-19. In addition, the dyes were fully removed in all the processes studied. Regarding the AO in cell with BDD/Ti, the degradation was positively influenced by the increasing in current density and doping of the electrode, primarily the kinetics parameters. In addition, total removal of RB-19 and RB-5 was achieved in 35 and 50 min of electrolysis when 100 mA cm-2 was applied to the electrode doped with 15,000 ppm ratio B/C. In 2 h, 37% in mineralization was attained for both dyes and the toxicity effect of the RB-19 decreased against the bacteria Vibrio fischeri. In this condition, total TOC removed was also reached after 8 h. The TOC removal was enhanced using the reactor fitted with BDD/Nb and RVC instead of the electrochemical cell, achieving TOC removal of 84 and 82% in 30 and 90 min for RB-19 and RB-5 which were removed in 7.5 and 5 min, respectively, when 41 mA cm-2 was applied to the BDD/Nb in the degradation exclusively via AO. Among the processes carried out in the reactor, the EF was the energetically most favourable since TOC removal of 60 and 74% for RB-19 and RB-5 with energy consumption of 204 and 208 kWh kg-1 were noted. In addition, the RB-19 and RB-5 were completely removed in 15 and 7.5 min, respectively, when the electrolyte containing 0.10 mmol L-1 of Fe2+ ions and -0.4 V vs Ag/AgCl was applied to CVR electrode. The combination of processes with electrogenerated H2O2 and AO for degradation of the dyes removed the RB-19 and RB-5 in 30 and 15 min with mineralization of 71.6 and 81.8% in 90 min associated to energy consumptions of 562 and 745 kWh kg-1 respectively, when 41 mA cm-2 was applied to BDD/Nb. Therefore, the degradation results of the dyes were promised since quickly removal of the dyes and partial mineralization were observed hence the proposed processes could be used to remove the dyes from water. However, more studies are needed to enable an industrial application, especially regarding the electrode material and configuration of the electrochemical system.
|
Page generated in 0.0583 seconds